HomeMy WebLinkAbout1413 BRANTA AVE; ; CB941160; PermitBUILDING PERMIT Permit No: CB941160
09/26/94 11:17 Project No: A9401628 Page 1 of 1 Development No:
Job Address: 1413 BRANTA AV Suite: Permit Type: SINGLE FAMILY DWLNG - DETACHED Parcel No: 215-621-03-00
Construction Type: VN
Occupancy Group: R3/M1 Reference#: CT85-35 Status: ISSUED Description: 2818 SF + 632 SF GAR + 70 SF Applied: 04/07/94
&&?& /3v4
Lot#: 27 &e,p 78 787 I Valuation: 233,708
/w94
13372 14
: DECK 94-200 AREA 14 CANTATA PLAN 2
Appl/Ownr : DAVIDSON COSCAN 619 481-8500
12865 POINTE DEL MAR #200
DEL MAR, CA 92014
Enter "Y" for Electric Issue Fee >
* ELECTRICAL TOTAL
Enter 'Y' for Mechanical Issue Fee>
Single Phase Per AMP >
Install Furn/Ducts/Heat Pumps >
Each Install Fireplace >
Each Install/Reloc Vent > * MECHANICAL TOTAL
,edits ***
.oo
350.00 13,372.14
Ext fee Data ---_-_--_-----
1070.00
696.00
22.00
2400.00
4051.00 Y
540.00
4666.14
13445.14
20.00 Y
98.00
15.00
7.00
7.00
7.00
14.00
168.00
10.00 Y
200 .25 50.00
60.00
15.00 Y
1 9.00 9.00
1 6.50 6.50
4 4.50 18.00
49.00
APPROVAL
CITY OF CARLSBAD
2075 Las Palms Dr., Carlsbad, CA 92009 (619) 438-1161
FINAL BUILDING INSPECTION !
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M WATER
’ PLAN CHECK#: CB941160 DATE:
PERMITI: CB941160 PERMIT PROJECT NAME: 2818 SF + 632 SF GAR + 70 SF
ADDRESS: 1413 BRANTA AV LOT# 27
SEWER DIST: CA WATER DIST: CA
DECK 94-200 AREA 14 CANTATA PLAN 2
CONTACT PERSON/PHONE#: EIW/JUSTIN/431-9541
DATE
INSPECTED: +-SFTROVED /DISAPPROVED -
INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED -
INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED -
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M WATER
-%AN CHECK#: CB941160 DATE:
JRHITI: CB941160 PERnIT
DECK 94-200 AREA 14 CANTATA PIAN 2
PROJECT NAME: 2818 SF + 632 SF GAR + 70 SF
ADDRESS: 1413 BRANTA AV uyP# 27
SEWER DIST: CA WATER DIST: CA
CONTACT PERSON/PHONE#: XW/JUSTIN/431-9541
04/18/95 TYPE: SFD
DATE
INSPECTED: $hy/&< APPROVED # DISAPPROVED - C INSPECTE
BY:
18 INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED -
INSPECTED DATE
BY: INSPECTED: APPROVED - DISAPPROVED -
COMMENTS :
. FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M WATER
PLAN CHECK#: CB941160 DATE :
PERMIT#: CB941160 PERMIT
PROJECT NME: 2818 SF + 632 SF GAR + 70 SF
DECK 94-200 AREA 14 CANTATA PLAN 2
ADDRESS: 1413 BRANTA AV LOT# 27
SEWER DIST: CA WATER DIST: CA CONTACT PERSON/PHONE#: MW/JUSTIN/431-9541
04/18/95
TYPE: SFD
ECEIVE 1 APR 19 1995 1
, BY
INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED -
COMMENTS :
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M WATER
PLAN CHECK#: CB941160 PERMIT#: CB941160 PROJECT NAME: 2818 SF + 632 SF GAR + 70 SP
DECK 94-200 AREA 14 CANTATA PLAN 2
ADDRESS: 1413 BRANTA AV UYF# 27
CONTACT PERSON/PHONE#: EIW/JUSTIN/431-9541
SEWER DIST: CA WATER DIST: CA
DATE: 04/18/95
PERMIT TYPE: SFD
INSPECTED DATE
BY: INSPECTED : APPROVED - DISAPPROVED -
INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED -
e
C ONSTRUCTXON T ESTING & ENGINEERING INC.
ESCONDIDO MODEST0
ENGINEERING, INC,
INSPECTION REPORT
WORK INSPECTION, JOB PROBLEMS, MATERIAL IDENTIFICATION PROGRESS,
WORK REJECTED, REMARKS, ECT.
Post tension tendon placement inspection has been performed this date for lots 19, 22, 27, 28, 29. Comments are as fol.lows:
Lot #27 - South perimeter location, tendon contact with vertical
DWV piping. Provide adequate clearance.
Lot #29 - Forming in progress @ depressed area. Verify adequate
tendon support.
South perimeter location, tendon supported by horizontal plumbing trap arm. Provide adequate clearance.
General comment all locations - Verify adequate dead end/form clearance.
Certification of compliance: All work, unless otherwise noted, complies with the approved plans, specifications and uniform
building code.
Inspector:
GEOTECIINICAL Rr CONSTRUCTION ENGINEERING TESTING & INSPECTION
2414 VINEYARD AVENUE SUITE C. USCONDIDO, CA 92029 (619) 746.4955 FAX (619) 746.9806
3540 OAKDALE ROAD IMOI)FSTO, CA 95355 (203) 551.2271 FAX (209) 551-3593