Loading...
HomeMy WebLinkAbout1437 YOURELL AVE; ; CB162623; Recycle(cityof Carlsbad RESIDENTIAL GREEN BUILDING CODE STANDARDS MANDATORY MEASURES CERTIFICATION CHECKLIST Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov 8-51 This form, signed and completed, and all receipts for the recycled materials shall be submitted to the Building Inspector prior to Final Inspection. Site Development Mandatory 4.106.2 A plan is developed and implemented to manage storm water drainage during construction. (X) 4.106.3 The site shall be planned and developed to keep surface water away from buildings. (X ) Construction plans shall indicate how site grading or a drainage system will manage all surface water flows. Energy Efficiency 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by (X) the California Energy Standards. Water Efficiency and Conservation Indoor Water Use 4.303.1 Indoor water use shall be reduced by at least 20 percent using one of the following methods: (X) 1. Water saving fixtures or flow restrictors shall be used. 7/01/2011 2. A 20 percent reduction in baseline water use shall be demonstrated. 4.303.2 When using the calculation method specified in Section 4.303.1, multiple showerheads shall not (X) exceed maximum flow rates. 7/01/2011 4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and shower heads) shall (X) comply with specified performance requirements. 7/01/2011 Outdoor Water Use 4.304.1 Automatic irrigation systems controllers installed at the time of final inspection shall be weather-(X) based. Enhanced Durability and Reduced Maintenance 4.406.1 Joints and openings. Annular spaces around pipes, electric cables, conduits or other openings in plates at exterior walls shall be protected against the passage of rodents by closing such openings (X ) with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Management Plan 4.408.1 A minimum of 50 percent of the construction waste generated at the site is diverted to recycle or (X) salvage. Recycled material receipts from approved recyclers must be attached to this form. 4.408.2 Where a local jurisdiction does not have a construction and demolition waste management ordinance, construction waste management plan, per form B-59, shall be submitted for approval to the (X ) enforcina aaencv. Building Maintenance and Operation 4.410.1 An operation and maintenance manual shall be provided to the building occupant or owner. (X) Environmental Quality Fireplaces 4.503.1 Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with US EPA Phase II emission limits where applicable. (X) Woodstoves, pellet stoves and fireplaces shall also complv with aoolicable local ordinances. B-51 Page 1 of 2 Rev. 11/15 Pollutant Control 4.504.1 Duct openings and other related air distribution component openings shall be covered (X) during construction. 4.504.2.1 Adhesive, sealants and caulks shall be compliant with VOC and other toxic compound (X) limits. (X) 4.504.2.2 Paints, stains and other coatings shall be compliant with voe limits. (X) 4.504.2.3 Aerosol paints and coatings shall be compliant with product weighted MIR limits for ROC and other toxic compounds. · 1 (X) 4.504.2.4 Documentation shall be provided to verify that compliant voe limit finish materials have been used. 4.504.3 Carpet and carpet systems shall be compliant with VOC limits. (X) 4.504.4 50 percent of floor area receiving resilient flooring shall comply with VOC-emission limits (X) defined in the Collaborative for High Performance Schools (CHPS) Low-emitting Materials List or be certified under the Resilient Floor Covering Institute (RFCI) FloorScore program. (X) 4.504.5 Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Vapor retarder and capillary break is installed at slab on grade foundations. (X) 4.505.3 Moisture content of building materials used in wall and floor framing is checked before (X) enclosure. Indoor Air Quality and Exhaust 4.506.1 Exhaust fans which terminate outside the buildinQ are provided in every bathroom. (X) Environmental Comfort 4.507.1 Whole house exhaust fans shall have insulated louvers or covers which close when the (X ) fan is off. Covers or louvers shall have a minimum insulation value of R-4.2. 4.507.2 Duct systems are sized, designed, and equipment is selected using the following methods: (X) 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent 3. Select heatinQ and coolinQ equipment according to ACCA 36-S (Manual S) or equivalent. Installer and Special Inspector Qualifications 702.1 HVAC system installers are trained and certified in the proper installation of HVAC (X) systems. 702.2 Special inspectors employed by the owner must be qualified and able to demonstrate (X) competence in the discipline they are inspectinQ. I, as the professional responsible for this project, certify that, to the best of my knowledge, the mandatory items listed on this form have been incorporated into the project in order to comply with Title 24, Part 11 of the 2013 California Green Building Standards. All receipts for recycled materials have been attached to this form. Project Address: l Li ;1 '--{Ovttu._, lh)t:. Plan Check Number: e_,(3 / h ,;)~:)/:_ Print Name: \?,~ t.f, u..f)YY:> Signed: ~ License Number: Date: fl-tt</{f/J B-51 ' Page 2 of 2 Rev. 11/15 · {ciiyof Carlsbad Owner: WASTE MANAGEMENT PLAN B-59 Contractor: Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Job Address:__,I_L/.L...."-~ _,_J~'t'---IJ-"-J-'-fUt,u,'---'---~--1/tY"--"-'.(,,~_ Phone Number: __ l~b_D_5.,_--_,,,z,_"-. .,_f_:,_,__,L'~'t...,<e"----- Permit#: Estimated Cost of Project: $ __ 1i-=.D__:o:_,_,_O_c>_o:__ _____ _ Type of Project: □ New Construction □ Remodel or T.I. □ Residential □ Commercial □ Demolition (check all that apply) 0'Dther 5'?'.c,.ol?]) O/j, 1/t(/lfU} 0 ,.,>li-Ll..,rl'J(r i )rJ/"[ Non-hazardous construction waste generated during the course of this project shall be recycled and/or salvaged for re-use at a minimum of 50% per CALGreen Sec. 5.408.1. Failure to comply may result in a penalty fee up to $1,000. For projects which consist of mainly equipment and/or racking, that have a combined weight of new construction disposal that does not exceed 2 lbs per square foot of building area affected by this permit, may be deemed to meet the 50% minimum requirement upon approval of Building Department. ALTERNATIVE FORMS OF COMPLIANCE: (If selected, do not complete Tables 1 & 2 below) ['] Construction waste shall not exceed 2 lbs. per sf. of area. All receipts shall be provided to the Building Official prior to final. (This option not applicable for most construction projects.) Square feet of construction area 1'?~0 X 2 lbs.= ·2r00cJ lbs. of allowable waste. D I plan on using a WASTE MANAGEMENT roll-off bin. All receipts shall be provided to the Building Official prior to final. Table 1 -Estimated Waste (To be filled out prior to permit issuance -refer to example on Page 2.) MATERIALS lbs. of waste to be taken to lbs. of waste to be Waste Hauling Company or Re~Use Method LANDFILL RE-US~D or RECYCLED Asphalt/ Concrete /) 'UfJ,()t} 0 ""'1illOvi::, f6 / /){/ M nt-J fl.eUA¥M Brick/ Masonry ?) {) cardboard //1 z:ou f,.)lf')"/JY,, I '/'t If" //1 ju-/ I Drywall {;) c) Landscape Debris 0 {,C)t:? t}/>r51~ ,-,i,Atrl.•,., . " Lumber/ Wood ,f') ?J>OO {1(3-1,/ ,:;(,P}Ga.L Metals ti n Mixed Waste CT) i) D l,) ;¥5-f £ ,,,._, ,ttr'/4-~VN W7 Trash I Garba'1e ;;: 1)0 u /,) l)t:;[,rJ'. pv-/rf)/i(rf,/f',VJ,-J, Other: TOTAL lbs: Estimated Percentage to be Re-Used or Recycled, ______ % I certi that the informati9[1 provided herein, to the best of my knowledge, is true and correct. l., [ UJJ VIL/ Date Official Use Only D Plan Approved D Plan Denied D Project Valuation Approved Reviewed/ Approved by: _________________ _ Page 1 of 2 Table 2 -Actual Waste (To be completed after construction.) MATERIALS lbs. of waste taken to lbs. of waste Waste Hauling Company or Re-Use Method LANDFILL RE-USED or RECYCLED (complete only if different than Table 1) Asphalt/ Concrete u i0t 000 Brick/ Masonry (/ 0 cardboard V c;Do Drywall u 0 Landscape Debris Q <,OD Lumber/ Wood V 1,,.00Z> Metals 0 0 Mixed Waste £.00 0 Trash / Garba•e <r>v fl Other: TOTAL lbs.: LO 00 1.,,r,000 Actual Percentage Re-Used or Recycled 4-< % Official Use Only D 50% Goal Achieved D 50% Goal Not Achieved D Alternative Compliance Achieved Penalty Paid $ _______ _ Reviewed/ Approved by: __________________ _ EXAMPLE: Use the following example as a guide to completing this form. MATERIALS lbs. of waste to be taken to lbs. of waste to be LANDFILL RE-USED or RECYCLED Asphalt / Concrete 0 :2000 Brick I Masonry iO0 450 Cardboard 0 150 Drywall 0 50 Landscape Debris 0 120 Lumber I Wood 500 0 Metals 300 200 Mixed Waste 1500 0 Trash I Garbage 300 0 Other: Pool CjuV\,lte 0 900 TOTAL lbs.: 2700 32J-0 Percentage to be Re-Used or Recycled 59 % Formula: Total Re-used or Recycled X 100 = % Re-Used or Recycled (Total Combined Waste) Waste Hauling Company or Re-Use Method A"!,C t-taullV\,C1 Co. WM / Re-L,\Sed 1,rld<c OV\,•Slte A 1,C u.a ullV\,C1 Cn. A"!,C t-taul[V\,c, Co. Mulc~ed s Re-used OV\,•Slte waste MaV\,aC1e""'-eV\,t WM/ A"!,C t-taullvcg WM WM L,\Sed as Crus~ed 1,nse ovc-slte 3870 X 100 = 59% Re-Used or Recycled (2700 + 3870) Since 59% exceeds the minimum requirement of 50%, this plan complies. Page 2 of 2 ' f . CONSTRUCTION & DEMOLITlON DIVERSION CERTIFICATE RECEIVED AT PROCESSED AT CUSTOMER c...M....::0....::0....::D:.....;Y--=S'---=E=L ..c::C..c::0..:...;RAZ=-=O.c..N--'-R=E...c.C=LA'""'MA_T_IO"""N __ DATE 3210 OCEANSIDE BLVD. OCEANSIDE. CA 760433-3316 ~r--~y~l_-e.._L-t_v___.'(~d ______ TICKET #: _____ _ PROJECT# OR DESCRIPTION TOTAL TONS RECEIVED: ---'''-------DIXERSION %: LOO SCALE HOUSE OPERA TORS SIGNATURE: This certifies that the company above has utilized a r~•,cling facility•to divert constructlcn demolition materials in accordance with LEED feQuirements The diversion' is based on ar, overall tonnage pen:enrage of the respective facility • ' Ag ri Service, Inc 3720 Ocoor!ic Way Suite 204 Oceanside,CA 92056 Customer: CASH Cash Cuslomer Truck 19 Trailer Material: WOOD Location: 0 Lie#: Weigh Master: CIS Driver: Remarks: Thanks visa 3365 Tipping at El Corazon Gross: 12700 Tare: 10700 Clean Wood Oceanside Net: 2000 $40.00/tn 1.000 CIS Ticket No : 170594 Date :7/21/17 Phone : (760)295-6255 Fax :(760)295-6262 Order No: 2 Brush40 Loads: 20,758 Miles: 0 Tons: 223.08 lb Scale 1 In lb Scale 1 Out lb tn Material$ Delivery$ Misc$ Tax$ Total$ Received$ Check# 2:53 pm 3:13 pm 40.00 0 00 0 00 0.00 40.00 40.00 4 , f CONSTRUCTION & DEMOLITION DIVERSION CERTIFICATE RECEIVED AT: -'-M-"O'-'O~D--'Y...;cS_-E=L~C;;:;..O~RAZ~"""'O'--N_R....;E"""'C'-"lAc.....Mcc..A'--T"'""'l=O"-'-N __ DATE: Y j,2.../ ~ .. t PROCESSED AT: 3210 OCEANSIDE BLVD. OCEANSIDE. CA 760-433-3316 CUSTOMER j(---j l(_,, L l O>j ct TICKET#:----- PROJECT # OR DESCRIPTION: CC2v1ut:fte:, Qtt/::hw'CA"/S /.1Vl,ct, :founfLiln TOTAL TONS RECEIVED: S D~X~RSION % ! 0 0 SCALE HOUSE OPERATORS SIGNATURE: __.,\,,..J;+-\ 1~~'-\*<"'---------- 1/ /) This certifies that the company above has utilized a recycling tar\ ity/t6 diVert construction demolition materials in accordance with LEED requirements The diversion• is i,asea on an overall tonnage percentage ✓ of the respective racility.