Loading...
HomeMy WebLinkAbout1440 BUENA VISTA WAY; ; CB072033; Permit10-162007 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad CA 92008 Residential Permit Permit No CB072033 Building Inspection Request Line (760) 602 2725 1440 BUENA VISTA WY CBAD RESDNTL Sub Type 2DU 1561205200 Lot# 0 $61 401 00 Construction Type VN Reference # 1 Structure Type MF2 4 1 Bathrooms 1 HALL RES 499 SF 2DU DETACHED & 389 SF ADJOINING WORKSHOP Status Applied Entered By Plan Approved Issued Inspect Area Ong PC# Plan Check# ISSUED 08/01/2007 RMA 10/16/2007 10/16/2007 Applicant HALL FAMILY TRUST 07 24 06 1440 BUENA VISTA WAY CARLSBAD CA 92008 Owner HALL FAMILY TRUST 07 24 06 1440 BUENA VISTA WAY CARLSBAD CA 92008 Building Permit Add I Building Permit Fee Plan Check Add I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add I Renewal Fee Other Building Fee HMP Fee Pot Water Con Fee Meter Size Add I Pot Water Con Fee Reel Water Con Fee $400 26 $000 $26017 $000 $000 $614 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 Meter Size Add I Reel Water Con Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (31 05540) PFF (4305540) License Tax (31 041 93) License Tax (43041 93) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing InLieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $1 11750 $1 031 54 $000 $000 $324 30 $365 70 $000 $13200 $2250 $4350 $2 925 00 $000 $000 $000 $1 058 00 $000 $7 686 61 Total Fees $7 686 61 Total Payments To Date $26517 Balance Due $7,421 44 Inspector FINAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively refer ed to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired City of Carlsbad 1635 Faraday Ave Carlsbad CA 92008 760-6022717/2718/2719 Fax 7606028558 Building Permit Application Plan Check No Plan Ck Deposit Date 1 JOB ADDRESS SUITE#/SPACE#/UNIT# CT/PROJECT*# BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR TYPE OCC GROUP DESCRIPTION OF WORK 359 EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF) "fa DECKS (SF)FIREPLACE YES D #NO.R AIR CONDITIONING YES D FIRE SPRINKLERS YES** NOD CONTACT NAME (If Different fom Applicant)APPLICANT NAME ADDRESS ADDRESS VIST* CITY STATE ZIP CITY ZIP PHONE FAX PHONE EMAIL EMAIL PROPERTY OWNER NAME CONTRACTOR BUS NAME ADDRESS ADDRESS CITY STATECA ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS CLASS CITY BUS LIC# (Sec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter, improve demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he ist—j . .. .L , .L. /•__. i ..... r/-<,apter 9 commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation of - -•' —'- -' --• more than five hundred dollars {$500}) ' licensed pursuant to the provisions of the Contractors ... , , Section 70315 by any applicant for a permit subjects the applicant to a Workers Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations L"J I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued n I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My workers compensation insurance carrier and policy number are Insurance Co Policy No Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less n Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees J£$ CONTRACTOR SIGNATURE DATE affirm that I am exempt from Contractors License Law for the following reason B I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractors License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) O I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) O I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O Yes D No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act' O Yes CJ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' n Yes O No Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' D Yes O No IF ANY OF THE ANSWERS ARE YES EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I cerdfythatl have read the application and state thattheabove information iscorrectandthatthemformaton on the plans isaccurate I agree to comply with all Cityordmancesand State laws relaftngtobuildingconstruction thereby authorize representative of the City of Carlsbad to enter upon Die above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authonzed by such permit is not commenced within 180 days from the date of such permit or if th§ bj^lellh^prjiprk authonzed b/such permit is suspended or abandoned at any time after the work B commenced for a penod of 180 days (Section 106 4 4 Uniform Building Code) > APPLICANTS SIGNATURE DATE City of Carlsbad Bldg Inspection Request For 03/31/2008 Permit* CB072033 Title HALL RES 499 SF 2DU DETACHED & Description 389 SF ADJOINING WORKSHOP) Type RESDNTL Sub Type 2DU Job Address 1440 BUENA VISTA WY Suite Lot 0 Location APPLICANT HALL FAMILY TRUST 07 24 06 Owner HALL FAMILY TRUST 07 24 06 Remarks AM PLEASE Total Time Inspector Assignment PC Phone Inspector Requested By NA Entered By CHRIS CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act—v Comments N6HE?. Comments/Notices/Holds Notice HOUSING FEE OF $2925 MUST BE PROCESSED WITH THE BUILDING FEES AND PAID ALL AT ONCE Associated PCRs/CVs Original PC# CommentsDate 02/19/2008 01/24/2008 01/24/2008 01/15/2008 01/15/2008 01/15/2008 11/27/2007 11/27/2007 11/19/2007 11/19/2007 11/14/2007 11/14/2007 Inspection History Description 17 Interior Lath/Drywall 14 Frame/Steel/Boltmg/Welding 44 Rough/Ducts/Dampers 13 Shear Panels/HDs 15 Roof/Reroof 24 Rough/Topout 31 Underground/Conduit Wiring 34 Rough Electric 11 Ftg/Foundation/Piers 23 Gas/Test/Repairs 21 Underground/Under Floor 23 Gas/Test/Repairs Act AP AP AP AP AP AP AP AP AP AP AP PA Insp PC PC PC PC PC PC PC PC PC PC PC PC VISUAL ON GAS LINE OK EsGil Corporation In Partnership with government for 'Smlding Safety DATE 9/26/07 'JURISJ) JURISDICTION Carlsbad tTPCATTREVIEWER a FILE PLAN CHECK NO 072033 SET III PROJECT ADDRESS 1440 Buena Vista Way PROJECT NAME Hall Accessory Dwelling unit with Workshop The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes IXI The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant s copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has beeri Person contacted Telephone # Mail Telephone Fax In Person REMARKS Please add City soils stamp to the plan By Tamara Fischer Enclosures Esgil Corporation D GA D MB D EJ D PC 9/18/07 9320 Chesapeake Drive Suite 208 + San Diego California 92123 * (858)560 1468 + Fax (858) 560 1576 EsGil Corporation In Partnership with government for 'Budding Safety DATE 9/5/07 O^APPI ICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 072033 SET II PROJECT ADDRESS 1440 Buena Vista Way PROJECT NAME Hall Accessory Dwelling unit with Workshop I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck A] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant s copy of the check list has been sent to Kevin Hall 1440 Buena Vista Way Carlsbad CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Kevin Hall Telephone # 760 758 5370 Date cojijacted yy/-/rf(b$fa) Fax # 858550-3410 Mail/ Telephone/ Fax l/ln Personv y REMARKS Please note that the area breakdown is slightly different than I reported on the original transmittal 499 sq ft dwelling, 389 sq ft garage By Tamara Fischer Enclosures Esgil Corporationn GA n MB n EJ n PC 8/28/07 9320 Chesapeake Drive Suite 208 + San Diego California 92123 *• (858)560 1468 + Fax (858) 560 1576 Carlsbad 072033 9/5/07 Please make all corrections as requested in the correction list Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department 1635 Faraday Ave , Carlsbad CA 92008 (760)602 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation 9320 Chesapeake Drive Suite 208 San Diego CA 92123 (858)5601468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning Engineering and Fire Departments until review by EsGil Corporation is complete NOTE The items listed below are from the previous correction list These items have not been adequately addressed The numbers of the items are from the previous check list and may not necessarily be in sequence The notes in bold are current I All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) Current sets are signed This will be verified on final sets Current sets are signed This will be verified on final sets I1 Garage requires one hour fire protection (i e 5/8 Type X drywall) on the garage side of walls and ceiling common to the dwelling Table 3 B Section 302 4 Section shows that workshop/dwelling wall does not extend to the roof sheathing Provide 2 layers 5/8 type x on the ceiling Section shows that ceiling joists are 16 o c while framing plans shows 24 oc 1 layer of 1/2 type C will not work for 24" o c spacing 12 Applicant to sign City Soils stamp prior to permit issuance agreeing to provide a soil report if the inspector detects problems This will be done at the City 14 If hold downs are required note on plan that hold down anchors must be tied in place prior to foundation inspection Section 108 5 2 See correction #22 below Unable to find this noted on the foundation plan 15 Please revise section A on sheet A2 0 to show footings extending minimum 12 below lowest adjacent grade show interior footing and show that finish grade slopes away from the building to provide drainage Please dimension 12 below the bottom of the slab at interior footing on section A and detail 1 on sheet A2 0 Carlsbad 072033 9/5/07 16 Please show the outline of the existing bomb shelter If the loads from the proposed structure will impact the bomb shelter at all a licensed engineer or architect will be required to provide a design a) Because the building is impacting the existing bomb shelter structure, please provide a design by a California licensed engineer or architect and have him or her stamp and sign the plans b) Detail 3 of A2 0 shows footings on both sides of the bomb shelter, but only one footing is shown on the foundation plan c) Show spacing of floor joists on detail 3 of A2 0 and specify all wood framing at that detail to be pressure treated d) How will the underfloor space (abandoned bomb shelter) be ventilated9 e) Please provide an accurate detail for footing above bomb shelter Detail 2/A2 which is referenced does not show the bomb shelter 22 In order to make the building comply with the conventional construction provisions for braced panels in section 2320 provide the following otherwise provide lateral calculations by a licensed engineer or architect c) A minimum 4 braced panel or 2 8 alternate braced panel at the west wall of living room within 8 of the north corner of the building Alternate braced panel requires hold downs at each end and a minimum of 2 anchor bolts and must be plywood not OSB Please specify the nailing of the plywood at alternate braced panel 23 Detail shear transfer connections at walls where rafters are parallel and at interior shear walls Please show interior shear walls to extend to the roof sheathing as the shear transfer detail provided is only intended when you have drag trusses on either side of the shear wall 37 New residential units must be pre-plumbed for future solar water heating Note "two roof jacks must be installed where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No 8093) This correction still applies even if the water heater is outside the building envelope 38 Note two 3/4 copper pipes must be installed to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof (City Ordinance No 8093) See bold remarks at #37 39 All piping for present or future solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (City Policy) See bold remarks at #37 Carlsbad 072033 9/5/O7 • To speed up the review process note on this list (or a copy) where each correction item has been addressed i e plan sheet note or detail number calculation page etc • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes please briefly describe them and where they are located in the plans • Have changes been made to the plans not resulting from this correction list? Please indicate • Yes Q No a • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive Suite 208 San Diego California 92123 telephone number of 858/560 1468 to perform the plan review for your project If you have any questions regarding these plan review items please contact Tamara Fischer at Esgil Corporation Thank you EsGil Corporation In Partnership a/it/i government for 'BuiUing Safety DATE 8/9/07 _ JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 072033 SET I PROJECT ADDRESS 1440 Buena Vista Way PROJECT NAME Hall Accessory Dwelling unit with Workshop The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant s copy of the check list has been sent to Kevin Hall 1440 Buena Vista Way Carlsbad CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Kevjn Hall Telephone # 760 758-5370 Date contacted^/<?/c?7(b>/^ Fax # 8585503410 Mail Telephone./ Fax ./In Person REMARKS By Tamara Fischer Enclosures Esgil Corporation D GA D MB D EJ D PC 8/2/07 9320 Chesapeake Drive Suite 208 + San Diego California 92123 * (858)560 1468 + Fax (858) 560 1576 Carlsbad O72O33 8/9/07 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO 072033 JURISDICTION Carlsbad PROJECT ADDRESS 1440 Buena Vista Way STORIES 1 HEIGHT 12 approxperUBC FLOOR AREA 561 sq ft dwelling 327 sq ft workshop REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED 8/9/07 DATE PLANS RECEIVED BY ESGIL CORPORATION 8/2/07 PLAN REVIEWER Tamara Fischer FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code Uniform Plumbing Code Uniform Mechanical Code National Electrical Code and state laws regulating energy conservation noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department Engineering Department Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24) which adopts the following model codes 1997 UBC 2000 UPC 2000 UMC and 2002 NEC The above regulations apply to residential construction regardless of the code editions adopted by ordinance The following items listed need clarification modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3 1997 Uniform Building Code the approval of the plans does not permit the violation of any state county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e. plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans Caflsbad O72033 8/9/07 Important Notice Regarding the 2007 CBC If you are an architect engineer designer or contractor that performs work within the State of California please be advised that a new building code will take effect on January 1 2008 The new building code is based on the 2006 International Building Code (IBC) and it is significantly different than the Uniform Building Code (UBC) All plan review applications submitted after December 31. 2007 will be required to comply with the new code The 2007 CBC is currently available for purchase directly from the International Code Council at www iccsafe org Please make all corrections as requested in the correction list Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department 1635 Faraday Ave Carlsbad CA 92008 (760)602- 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation 9320 Chesapeake Drive Suite 208 San Diego CA 92123 (858)5601468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning Engineering and Fire Departments until review by EsGil Corporation is complete 1 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) Current sets are signed This will be verified on final sets 2 Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling and workshop Please separate out the areas (It should be 561 sq ft dwelling 327 sq ft workshop) 3 Please dimension the distance between the proposed building and the existing house on the site plan 4 Openable window area in bathrooms and water closet compartments is required to be 1/20 of area 2 sq ft is required while 1 5 sq ft provided Section 12033 5 Provide mechanical ventilation capable of providing five air changes per hour in bathrooms and water closet compartments if required openable windows are not Carlsbad 072033 8/9/07 provided Section 1203 3 6 Dimension on the plans 30 clear width for water closet compartments Section 2904 7 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 (see exceptions) a) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24 inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface Window next to door in living room 8 Required exit doorways shall be not less than 36" in width and not less than 6 8 in height Section 1003 3 1 3 (Workshop door) 9 Per local ordinance a Class A roof is required Please specify composite shingles to be Class A 10 Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters) The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents) Show area required and area provided Section 1505 3 11 Garage requires one hour fire protection (i e 5/8 Type X drywall) on the garage side of walls and ceiling common to the dwelling Table 3 B Section 302 4 Section shows that workshop/dwelling wall does not extend to the roof sheathing Provide 2 layers 5/8 type x on the ceiling 12 Applicant to sign City Soils stamp prior to permit issuance agreeing to provide a soil report if the inspector detects problems 13 If required show size embedment and location of hold down anchors on foundation plan Section 106 3 3 See correction #22 below 14 If hold downs are required note on plan that hold down anchors must be tied in place prior to foundation inspection Section 108 5 2 See correction #22 below 15 Please revise section A on sheet A2 0 to show footings extending minimum 12 below lowest adjacent grade show interior footing and show that finish grade slopes away from the building to provide drainage 16 Please show the outline of the existing bomb shelter If the loads from the proposed structure will impact the bomb shelter at all a licensed engineer or architect will be required to provide a design Carlsbad O72O33 8/9/07 17 The footing at detail 1 of A2 0 cannot be used for bearing or shear walls (It would need 12 depth below lowest adjacent grade an additional #4 bar at the top and 5/8 anchor bolts with plate washers for shear walls) It appears ceiling joists are bearing on interior walls as they would be overspanned otherwise 18 Please identify what PT sole plates are sitting on at detail 3/A2 0 and show 18 minimum clearance to floor joists unless they are pressure treated 19 Show double top plate with minimum 48 lap splice Section 2320 11 2 Wall section sheet A2 0 shows one top plate 20 Show stud size and spacing 21 Please specify the lengths of shear panels shown 22 In order to make the building comply with the conventional construction provisions for braced panels in section 2320 provide the following otherwise provide lateral calculations by a licensed engineer or architect a) A minimum 4 braced panel to the roof sheathing at wall between bath and workshop b) A minimum 4 braced wall panel to roof sheathing at wall between bedroom and kitchen c) A minimum 4 braced panel or 2 8 alternate braced panel at the west wall of living room within 8 of the north corner of the building Alternate braced panel requires hold downs at each end and a minimum of 2 anchor bolts and must be plywood not OSB 23 Detail shear transfer connections at walls where rafters are parallel and at interior shear walls 24 Specify roof diaphragm plywood and/or particle board thickness grade and panel span rating Table 23 ll-E-1 25 Show location of attic access with a minimum size of 22 x30 unless the maximum vertical headroom height in the attic is less than 30 Access must be provided to each separated attic area shall be located in a hallway or other readily accessible location and 30 headroom clearance is required above the opening Section 1505 1 26 Note on the plans that receptacle outlet locations will comply with NEC Art 210-52(a) As shown bedroom and living room do not comply 27 For a single family dwelling unit (and for each unit of a duplex) show that at least one receptacle outlet accessible at grade level will be installed outdoors at the front and back of the dwelling NEC Art 210 52 (e) This receptacle must be GFCI protected Carlsbad O72033 8/9/O7 28 GFCI protected receptacle outlets are required within 25 feet of all mechanical equipment (heating air conditioning and refrigeration equipment) Please show on plans NEC 21063 29 All bedroom branch circuits now require arc fault protection Note clearly on the plans that Bedroom branch circuits will be arc fault circuit protected NEC Art 210-12(b) 30 Show on the plan that ground fault circuit interrupter protection complies with NEC Art 2108 which reads as follows AII125-volt single phase 15 and 20 ampere receptacles installed in bathrooms garages (workshop) outdoors and kitchen counters 31 Specify the water heater type and capacity on the plans Provide manufacturer s information for water heater showing it is approved for an outdoor location 32 Show T and P valve on water heater and show route of discharge line to exterior UPC Section 608 5 33 In Seismic Zones 3 and 4 show that water heater is adequately braced to resist seismic forces Provide two straps (one strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank) UPC Section 510 5 34 Package D requires a maximum SHGC of 4 for fenestration products (windows) CF-1R shows SHGC of 65 35 The values shown for area of fenestration products on page 2 of CF 1R are incorrect They should match the areas shown on the fenestration worksheet 36 Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement) a) In the kitchen at least one half of the wattage rating of the fixtures must be high efficacy with non-high efficacy fixtures switched separately Note Approximately % of the fixtures will be required to be of the high efficacy variety Fixture shown on electrical plan does not appear to be high efficacy b) In bathrooms and workshop all fixtures must be high efficacy style or be controlled by a manually on occupancy sensor c) Outdoor lighting fixtures are required to be high efficacy or controlled by a combination photocontrol/motion sensor Note Generally a high efficacy style of fixture is fluorescent complete with electronic ballasts Regular incandescent quartz halogen and halogen MR lamps do not comply Carlsbad 072033 8/9/07 37 New residential units must be pre-plumbed for future solar water heating Note two roof jacks must be installed where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No 8093) 38 Note two 3/4 copper pipes must be installed to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof (City Ordinance No 8093) 39 All piping for present or future solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (City Policy) • To speed up the review process note on this list (or a copy) where each correction item has been addressed i e plan sheet note or detail number calculation page etc • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes please briefly describe them and where they are located in the plans • Have changes been made to the plans not resulting from this correction list9 Please indicate • Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive Suite 208 San Diego California 92123 telephone number of 858/560 1468 to perform the plan review for your project If you have any questions regarding these plan review items please contact Tamara Fischer at Esgil Corporation Thank you Carlsbad 072033 8/9/07 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO 072033 PREPARED BY Tamara Fischer DATE 8/9/07 BUILDING ADDRESS 1440 Buena Vista Way BUILDING OCCUPANCY R3/Ul TYPE OF CONSTRUCTION VN BUILDING PORTION sfd dwelling workshop Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 561 327 cb Valuation Multiplier 101 99 2661 By Ordinance Reg Mod VALUE ($) 57216 8701 65,918 Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review I I Repetitive Fee Repeats Complete Review D Other i—I Hourly D Structural Only Hour Esgil Plan Review Fee Comments $406 661 $264 33 $227 73 Sheet 1 of 1 macvalue doc City of Carlsbad BUILDING PLANCHECK CHECKLIST DATE /£/Q7 BUILDING ADRESS PROJECT DESCRIPTION ASSESSOR S PARCEL NUMBER PLANCHECK NO CB Q ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans information and/or specifications provided in your submittal therefore any changes to these items after this date including field modifications must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to build D A Right of Way permit is required prior to construction of the following improvements EST VALUE DENIAL ?/ Please see the attached report of deficiencies marked with D Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By By By Date Date Date By FOR OFFICIAL USE ONLY N. r^^ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT ^X Date D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right of Way Permit Application [] Right of Way Permit Submittal Checklist and Information Sheet D Sewer Fee Information Sheet Name ENGINEERING DEPT CONTACT PERSON JOANNE JUCHNIEWICZ City of Carlsbad Address 1635 Faraday Avenue Carlsbad CA 92008 Phone (760) 602 2775 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract e Car|sbad CA 92OO817314 • (76O) 602 2720 • FAX (760) 6O2 D D BUILDING PLANCHECK CHECKLIST SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show A North Arrow B Existing & Proposed Structures C Existing Street Improvements D Property Lines E Easements 2 Show on site plan F Right-of-Way Width & Adjacent Streets G Driveway widths H Existing or proposed sewer lateral I Existing or proposed water service J Existing or proposed irrigation service A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE Finish grade will provide a minimum positive drainage of 2% to swale 5 away from building B Existing & Proposed Slopes and Topography C Size type location alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service however second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways per standards 3 Include on title sheet A Site address Assessor s Parcel Number C Legal Description n && oV For commercial/industrial buildings and tenant improvement presets include total building square footage with the square footage for each differenx use existing sewer permits showing square footage of different uses (manufacturing warehouse office etc) previously approved EXISTING PERMIT NUMBER DESCRIPTION F WILDING PLANCHECK CKLST FORM d R 7/14/00 BUILDING PLANCHECK CHECKLIST ,ND RD D D 3 D DISCRETIONARY APPROVAL COMPLIANCE 4a Project does not comply with the following Engineering Conditions of approval for Project No CD CD 4b All conditions are in compliance Date DEDICATION REQUIREMENTS 5 Dedication for all street Rights of Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17,000 pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows T _ Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 V* x 11 plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date IMPROVEMENT REQUIREMENTS D D 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82,000 pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F \BUILDING PLANCHECK CKLST FORM d BUILDING PLANCHECK CHECKLIST . ST checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18 40 Please submit a recent property title report or current grant deed on the property and processing fee of $410 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed notarized and approved by the City prior to issuance of a Building permit D Future public improvements required as follows 6c Enclosed please find your Neighborhood Improvement Agreement agreement signed and notarized to the Engineering Department Please return Neighborhood Improvement Agreement completed by Date EH CH EH 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy nan a GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15 16 010 of the Municipal Code 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut fill import export and remedial) This information must be included on the plans 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) F \BUILDING PLANCHECK CKLST FORM doc u BUILDING PLANCHECK CHECKLIST ..ST 2ND 3RD n D D 7d No Grading Permit required n D D 7e If grading is not required write No Grading on plot plan MISCELLANEOUS PERMITS D D D 8 A RIGHT OF WAY PERMIT is required to do work in City Right-of Way and/or private work adjacent to the public Right of Way Types of work include but are not limited to street improvements tree trimming driveway construction tying into public storm dram sewer and water utilities Right-of Way permit required for D D D 9 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area you need to contact the Carlsbad Municipal Water District located at 5950 El Cammo Real Carlsbad CA 92008 District personnel can provide forms and assistance and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438 2722 extension 7153 for assistance Industrial Waste permit accepted by Date D D D 10 NPDES PERMIT Complies with the Citys requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit whichever occurs first L~H d L~H 11 D Required fees are attached D No fees required WATER METER REVIEW D D D 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low flow conditions If it is oversized for the life of the meter the City will not accurately bill the owner for the water used • All single family dwelling units received standard 1 service with 5/8 service F \BUILDING PLANCHECK CKLST FORM d D D D i2b BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the standard then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided check against the meter sizing schedule to verify the anticipated meter size for the unit • Maximum service and meter size is a 2 service with a 2 meter • If a developer is proposing a meter greater than 2 suggest the installation of multiple 2 services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998) check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so at the water meter station the demand in gpm may be listed there Irrigation services are listed with a circled I and potable water is typically a circled W The irrigation service should look like STA1+00 Install 2 service and 1 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course) then the applicant must provide irrigation calculations for estimated worst case irrigation demand (largest zone with the farthest reach) Typically Larry Black has already reviewed this if landscape plans have been prepared but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water F BUILDING PLANCHECK CKLST FORM d -ST 2ND 3RD BUILDING PLANCHECK CHECKLIST service boundary the City intends on switching these irrigation services/meters to a new recycled water line in the future D D D 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water then they should be connecting to this line to irrigate slopes within the development For subdivisions this should have been identified and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However if they front a street which the recycled water is there but is not live (sometimes they are charged with potable water until recycled water is available) then the applicant must pay the San Diego Water Capacity Charge If within three years the recycled water line is charged with recycled water by CMWD then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However let the applicant know that we cannot guarantee the refund and they must deal with the SDCWA for this El EH d 13 Additional Comments F \BUILDING PLANCHECK CKLST FORM d ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET itimate based on unconfirmed information from applicant Calculation based on building plancheck plan submittals^Ca Address IWO WJ^^*- IA ^ Permit No 072035 Prepared by.Date Checked by Date EDU CALCULATIONS List types and square footages for all uses Types of Use ^^)V3 Sq Ft /Units Types of Use Sq Ft/Units APT CALCULATIONS List types and square footages for all uses Types of Use C\)\J Sq Ft/Units Types of Use Sq Ft /Units EDUs EDUs ADTs . ADTs FEES REQUIRED WITHIN CFD D YES (no bridge & thoroughfare fee in District #1 reduced Traffic Impact Fee)B^JO PARK IN LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS/ 2 TRAFFIC IMPACT FEE ADTs/UNITS / B BRIDGE AND THOROUGHFARE FEE ADTs/UNITS ^j4 FACILITIES MANAGEMENT FEE ^ UNIT/SO FTs 5 SEWER FEE EDUs / j^fklEFITAREA EDUs X FEE/ADT ^ 7^ (DIST #1 DIST #2 X FEE/ADT ZONE / X FEE/SO FT /UNIT X FEE/EDU (Ol ' X FEE/EDU =$_ =$ h ¥2 DIST #3 =$_ =$_ =$ 6 SEWER LATERAL ($2 500) 7 DRAINAGE FEES PLDA _ ACRES _ X 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE =$- =$_ HIGH FEE/AC /LOW =$ METER FEE SDCWA FEE SDCWA FEE F \FEECALCULATION WORKSHEET doc 1 of 2 Rev 7/14/00 r- -* m J£o o o» » O ooo DD D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB 0 I 'Ufflf) Planner Gma Ruiz Address \.°^CO ^U^NA N Phone (760) 602 4675 mA WAV APN \fy> \10 ^l 00 Type of Project & Use *& - £ **• t?U *fa Zoning fc-1 General Plan KLVt CFD (m/out) # Date of participation £££?> Net Proiect Densitv Facilities Management Zone 1 Remainma net dev acres DU/AC Circle One (For non residential development Type of land used created by this permit ) Legend £3 Item Complete D Item Incomplete Needs your action Environmental Review Required YES NO X^ TYPE DATE OF COMPLETION Compliance with conditions of approval7 'If not state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/PESO NO PROJECT NO YES DATE NO X TYPE OTHER RELATED CASES Compliance with conditions or approval7 If not state conditions which require action Conditions of Approval n Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES CA Coastal Commission Authority7 YES NO X If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive Suite 103 San Diego CA 921084402 (619)7672370 Determine status (Coastal Permit Required or Exempt) _ NO- Habitat Management Plan Data Entry Completed7 YES If property has Habitat Type identified-^ Table 11xofjHMP" complete HMP Permit application and assess fees in Permits Plus (A/P/Ds Activity Maintenance enter CB# toolbar Screens HMP Fees Enter Acres of Habitat Type impacted/taken UPDATE') fi > NO 'Inclusionary Housing Fee required YES (Effective date of Inclusionary Housing Ordinance May 21 1993) Data Entry Completed7 YEsX NO (A/P/Ds Activity Maintenance enter CB# toolbar Screens Housing Fees Construct Housing Y/N Enter Fee UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 D Site Plan Provide a fully dimensional site plan drawn to scale Show North arrow property lines easements existing and proposed structures streets existing street improvements right of way width dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor s parcel number Policy 44 - Neighborhood Architectural Design Guidelines D D 1 Applicability YES NO D D 2 Project complies YES. NO_ DD D D S D D H D D Zoning 1 Setbacks Front Interior Side Street Side Rear Top of slope 2 Accessory structure setbacks Front Interior Side Street Side Rear Structure separation 3 Lot Coverage Required Required Required Required Required :ks Required Required Required Required Required Required '(>V &)* hJ/A ID' KJ/A- M*c??< MA }<?' 10' <4o/ Shown t" Shown ~T ' 3\ &> ' Shown Shown 10' Shown Shown Shown ^'^"T Shown Shown [Of Shown U'f?' Shown fyO \ot I 4 Height Required Spaces Required Shown Shown5 Parking (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required I Shown l_ Additional Comments AfPlPAN/lT 1*7 && A CITV ^i $1' AIL OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTERL-^lUft Q>J^L DATE H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 CITY OF CARLSBAD - AFFIDAVIT OF COMPLIANCE FOR A SECOND DWELLING UNIT Instructions to Property Owner (Affiant') Please type or print complete and accurate answers in all blank spaces in Section I Please read carefully, particularly Section II Please read, sign and date Section III indicating that you understand and agree with the conditions of compliance SECTION I - INFORMATION Property owner(s)+ Name(s) Property Address Street Address City Assessor Parcel No Subdivision Project Number Name State / Lot/Block 07 Zip Code Parcel No SECTION II - CONDITIONS FOR COMPLIANCE PLEASE READ CAREFULLY 1 A second dwelling unit is an attached or detached dwelling unit which is located on the same lot as an existing owner occupied single family detached dwelling unit and is a Suitable for use as a complete living facility with provisions within the facility for cooking eating sanitation and sleeping b Occupied by one or more persons and c Subordinate to the mam dwelling unit 2 The Property Owner(s) listed above hereby certifies that he/she owns the above referenced property as of the date of this affidavit and to his/her belief and knowledge there are no conditions covenants or restrictions on the property prohibiting a second dwelling unit apartment 3 The Property Owner(s) agrees to the following terms and conditions FRM0006 6/03 PAGE 1 OF 2 a The property and residence referenced above must not contain a second residential dwelling unit unless it is in compliance with the second dwelling unit provisions of the Zoning Ordinance of the City of Carlsbad b The Property Owner(s) shall reside in either the mam dwelling unit or second dwelling unit described above now and for the life of this agreement unless a lessee leases both the mam dwelling unit and the second dwelling unit c The Second Dwelling Unit may only be rented and shall not be sold separately from the main dwelling unit unless the lot on which such units are located is subdivided d The Property Owner(s) agree to rent the Second Dwelling Unit at a monthly rental rate which shall not exceed an amount equal to 30% of the gross monthly income of a low income household adjusted for household size at 80% of the San Diego County median income e A copy of this agreement and Affidavit must be given by the Property Owner(s) to prospective purchasers of the property prior to entering into a sales contract for said property SECTION III - AFFIRMATION AND AGREEMENT I HEREBY DECLARE AND AFFIRM under penalty of perjury that all matters and facts set forth in this agreement are true and correct to the best of my knowledge information and belief and that I (we) understand accept and will abide by the regulations requirements and standards governing the Second Dwelling Unit BY -Property Owner Date ^roperty Owner Date Owner s Telephone Number(s) £_ Home Office FRM0006 6/03 PAGE 2 OF 2 CERTIFICATE OF COMPLIANCE RESIDENTIAL (Page l of 5) CF-1R Project Title , / rail A-6e£/ hu;?/l 4* Av/tfCsli Project Address . /, Date / / 1A ~l 1 2S*>lt>~l o ' , c i1 IS uf?«*-<< I/ S rx_ / A.h( <; 60^ ^ ^ #200 *? Documentation Author [j®!^ fH.0^f|£ Compliance-Method (Prescriptive) Telephone ( "7(^0 ) Ip^ " ?3^7- Climate Zone Building Permit # Plan Check / Date Field Check /Date Enforcement Agency Use Only Alternative Component Package Method (check one)_D (Alternative) Package C and Package D choices require HERS rater field verification and/or diagnostic testing (see CF 1R page 3) For Package D Alternative see Appendix B Table 151 C Footnotes 8 14 in the Residential Compliance Manual (RCM) ft2 GENERAL INFORMATION Total Conditioned Floor Area (CFA) <-H Average Ceiling Height ffi ft Check Applicable Boxes Building Type (check one or more) ^Single Family Multifamily Addition Alteration (If adding fenestration fill-out WS-4R, Fenestration Maximum Allowed Area Worksheet and see Section 832 for Additions and 8 3 3 for Alterations in the RCM ) ft2 (from WS-4R) " ft2 (from WS-4R) Maximum Allowed Total Fenestration Area Maximum Allowed West Facing Fenestration Area Number of Stones \ Number jjf Dwelling Units ( Floor Construction Type (SlaEftlaised Floor j[circle one or both) Front Orientation Norm/South / East /(Wesy All Orientations (input front orientation in degrees from True North and circle one) D RADIANT BARRIER (check box if required in climate zones 2.4.8 15) OPAQUE SURFACES INCLUDING OPAQUE DOORS Component Type (Wall Roof Floor Slab Edge Doors) t^nUl fWf <*kVi Frame Type (Wood or Metal) Ljff»fJ( LV/ftodP Cavity Insulation R Value t ~»3.^•Ttf Continuous Insulation R Value GL-I-? jt^-50 Assembly U factor (for wood metal frame and mass assemblies) ' {qo 40 Joint Appendix IV Reference tf f*Oa} fir* Roof Radiant Barrier Installed2 Yes or No Location Comments (attic garage typical etc ) 1) See Joint Appendix IV in Section IV 2 IV 3 and IV 4 which is the basis for the U factor criterion U factors can not exceed prescriptive value to show equivalence to R values 2) This column is for the Inspector to verify installation of roof radiant barrier Residential Compliance Forms December 2005 ~ -2. - 1_ -^ 1? S 5 V r *S>i I rf «<? r