Loading...
HomeMy WebLinkAbout1465 CHESTNUT AVE; ; CB004154; Permit12/06/2000 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad ,.• 1635 Faraday Av Carlsbad, CA 92008 , Residential Permit Permit No:CB004154 Building Inspection Request Line (760) 602-2725 1465 CHESTNUT AV CBAD RESDNTL Sub Type: 2052206700 Lot #: $34,496.00 Construction Type: 27 Reference #: 0 Structure Type: 0 Bathrooms: ELLIOT RESIDENCE RAD 352 SF - DINE RM & BATHRM RAD 0 VN Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Check#: ISSUED 11/09/2000 JM 12/06/2000 12/06/2000 Applicant: ELLIOTT FAMILY REVOCABLE TRUST 09-21-98 PO BOX 4115 CARLSBAD CA 92018 Owner: ELLIOTT FAMILY REVOCABLE TRUST 09-21-98 PO BOX 4115 «» 12/06/00 OMB01 CARLSBAD CA 92018 02 418-28 Total Fees: $618.37 , Total Payments To Date: $200.09 Balance Due: $418.28 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $307.83.. Meter Size $0;00l;::: Add'l:Recl:3/Vater Con. Fee $200.09 *~ - xMeter-Fee $OM SDGWA Fee $0.00' V CFD PayoffFee $3:4V \v "tff Fi'--.S' $0.b6( \ F>FF- (CFD Fund) $0.00;i >; License Tax $O.OC);: ": ' License Tax (CFD Fund) $0:00;\ \ Traffic Impact Fee $0:00 J Traffic Impact (CFD Fund) $0,00 J-FMZ Transportation Fee $0.00 '""'Sidewalk Fee $0.00 PLUMBING TOTAL $0,00 .'> ELECTRICAL TOTAL $0.00•").•',:.-. MECHANICAL TOTAL $0.00 , Housing Impact Fee ./ 'I [ Housing' iViLieu Fee $0.00 Master Drainage Fee: $0.00 Sewer Fee: ' TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $63.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 $618.37 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 i: PROJECT INFORMATIONi46 FOR OFFICE USE PLAN CHECK NO. EST. VAL. Plan Ck. Deposjt Validated By_ Date . A. / Address (include Bldg/Suite #) PfrgjC HftP"*- U-3q ) Lot No. Subdivision N Business Name (at this address) Legal Description ^•S" • ^2 Assessor's Parcel lame/Number Unit No. ?r2-SQ pr | Description of Work 2. CONTACT PERSON #of Stories State/Zip V^Telephone # "Fax #Name " ^ " Address City 3, APPLICANT D Contractor . O Agent for Contractor jSjgwner D Agent for Owner .Name 4. PROPERTY OWN Address State/Zip Telephone # City State/Zip Telephone #Name ' Address S. CONTRACTOR - COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, imprgy:e^aenr1o]is1J)or,.f^|PairjBnyjStructure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provTsTons of the Contractors Lice~rise Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, andtJfiOC8^^ for tne all?£ied exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [«cnrin*--'- " Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name Address City State/Zip Telephone State License # 6. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: n I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. l~l I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is • issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) |~| CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation .Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE : DATE OWNER-BUILDER DECLARATION iy affirm that I am exempt from the Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale . 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). fl\ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The ' CoHtractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). l~l I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. l~l YES flNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but jjiave contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): DATE BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? fj YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? l~l YES l~l NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A F(NAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS 9. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by suet] permit is/suspended or abandoned at any time after the work is commepeeKfterajjeripd o^gOdajis4£^roTrW6.4.4 Uniform Building Code). APPLICANT'S SIGNATUR^ofi^^fe^ ^U^ ( ) 30UI DATE | ( PINK: Finance City of Carlsbad Bldg Inspection Request For: 04/02/2001 Permit# CB004154 Title: ELLIOT RESIDENCE Description: RAD 352 SF - DINE RM & BATHRM Inspector Assignment: JC Type:RESDNTL Sub Type: RAD Job Address: 1465 CHESTNUT AV Suite: Lot 0 Location: APPLICANT ELLIOTT FAMILY REVOCABLE TRUST 09-21 -98 Owner: ELLIOTT FAMILY REVOCABLE TRUST 09-21-98 Remarks: Phone: 7607202235 Inspector: *\/, Total Time:Requested By: TOM CD 19 29 39 49 Entered By: CHRISTINE Description Act Comments Final Structural (~/,J Final Plumbing Final Electrical / Final Mechanical , Associated PCRs Inspection History Date Description 02/20/2001 17 Interior Lath/Drywall 02/15/2001 16 Insulation 02/12/2001 84 Rough Combo 02/01/2001 83 Roof Sheathing/Ext Shear 01/08/2001 11 Ftg/Foundation/Piers 01/05/2001 11 Ftg/Foundation/Piers 01/05/2001 12 Steel/Bond Beam 01/03/2001 21 Underground/Under Floor 01/02/2001 22 Sewer/Water Service Act Insp Comments AP JC AP JC AP JC AP CA AP AP CA AP JC JC JC JC JC JC j[ Corporation In fartnersnip with government for ViuiCcting Safety DATE: November 28, 2000 q__AEEUQANT LJURIS. JURISDICTION: Carlsbad O~PLAN REVIEWER: - • ' a FILE PLAN CHECK NO.: 00-4154 SET: I PROJECT ADDRESS: 1465 Chestnut Ave. PROJECT NAME: Addition for the Elliott Residence The plans transmitted herewith have been corrected where necessary and substantially comply, with the jurisdiction's building codes. XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: /Wjf Mail Telephone Fax In Person —-—- -^ " REMARKS: Engineer of design to wet stamp and sign plans, also providICBO for skylight on plans. By: Bill Elizarraras Enclosures: Esgil Corporation -: D GA D MB D EJ D PC 11/14/00 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 •* (858)560-1468 + Fax (858) 560-1576 Carlsbad 00-4154 November 28, 2000 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 00-4154 JURISDICTION: Carlsbad PROJECT ADDRESS: 1465 Chestnut Ave. FLOOR AREA: 352 sqft. Dwelling Add'n STORIES: 1 HEIGHT: 14' REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: November 28, 2OOO DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/14/00 PLAN REVIEWER: Bill Elizarraras FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 1998 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked UP list when you submit the revised plans. Carlsbad OO-4154 November 28, 2000 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 00-4154 PREPARED BY: Bill Elizarraras DATE: November 28, 2000 BUILDING ADDRESS: 1465 Chestnut Ave. BUILDING OCCUPANCY: R3/U1 TYPE OF CONSTRUCTION: VN BUILDING PORTION Dwelling Add'n Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 352 cb - ' Valuation Multiplier City Estimate By Ordinance i 1 Bldg. Permit Fee by Ordinance ^ Reg. Mod. VALUE ($) 34,496 34,496 34,496 307.83 i Plan Check Fee by Ordinance Type of Review: CH Repetitive Fee Repeats 0 Complete Review CD Structural Only D Other D Hourly Esgil Plan Review Fee Comments: 200.09 160.07 Sheet 1 of 1 macvalue.doc BUILDING PLANCHECK CHECKLIST DATE:/ob BUILDING ADDRESS: / 5 PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: PLANCHECK NO.: CB EST. VALUE: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. A Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please sea Vn&/ attached report of deficiencies marked withJSJTMake necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. Date: Date: Date:By: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: Date: ATTACHMENTS Dedication Application Dedication Checklist Improvement Application Improvement Checklist Future Improvement Agreement Grading Permit Application Grading Submittal Checklist Right-of-Way Permit Application Right-of-Way Permit Submittal Checklist and Information Sheet Sewer Fee Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: JOANNE JUCHNIEWICZ City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2775 CFD INFORMATION Parcel Map No: _| Lots: Recordation: Carlsbad Tract: A-4 H:\WORD\DOCSVCHKLST\BuikJin8 Planctreck Cklst Form (GenericJ.doc 3RD BUILDING PLANCHECK CHECKLIST /IA5 SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow B. Existing & Proposed Structures C._ Existing Street Improvements Property Lines - £&-€- . Easements F. Right-of-Way Width & Adjacent Streets G. Driveway widths H. Existing or proposed sewer lateral I. Existing or proposed water service J. Existing or proposed irrigation service 2. Show on site plan: A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION H:\WORD\DOCS\CHKLST\Buitting Planctecfc Cklst Form (Generic).doc BUILDING PLANCHECK CHECKLIST ST 2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No. 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS Q D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15.000. pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: ' Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Yz" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS D 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75.000. pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the H:\WORD\DOCS\CHKLST\BuBding Plancheck Cklst Form (RIDDLE - HARVEY 7-12-OOl.doc BUILDING PLANCHECK CHECKLIST 3rd checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: CH D CH 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $280 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Neighborhood Improvement Agreement will include the following: 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: Date: 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. n D 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). D D 7b.. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: • Date: D D D 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) H:\WORD\DOCS\CHKLST\Buikfing Planctieck Cklst Form (RIDDLE - HARVEY 7-12-00).doc 1ST D D n n BUILDING PLANCHECK CHECKLIST 7d .No Grading Permit required. 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: .• n Q D 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. 1 1 • Q Required fees are attached QfNo fees required WATER METER REVIEW 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. H:WVORDVDOCS\CHKLST\Building Plancheck Cklst Fomi (Geneiic).doc BUILDING PLANCHECK CHECKLIST 1ST 5ND 3RD D D • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand, (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: 1. If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA 1+00 Install 2" service and 2. 3. 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water H:\WORD\DOCS\CHKLST\Buikling Plancheck Cklst Form (Generic).** BUILDING PLANCHECK CHECKLIST 2ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. ED ED 12c. Irrigation Use (where recycled water Is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until, recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. D D CD 13- Additional Comments: H:\WORD\DOCS\CHKLST\BuikJing Plancfteck Cklst Form (Generic).doc l&TA&L IQ7.&0') ° 2/'<%?" I/0T. 73 12.0.06') -/Z0.17' PARCEL 2 10, TAG, MARKED LS 3338 <r-v ,; ^v_x\>.- r',v O I £ I I D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB H15M Planner APN: Address Chc&bnuV AN/ Phone (760) 602- Type of Project & Use: T\ Zoning: R~ 1 General Plan: CFD fin/nut) # Circle One _Date of participation^ Net Project Density: DU/AC _ Facilities Management Zone: I Remaining net dev acres: (For non-residential development: Type of land used created oy this permit: ) Legend: X Item Complete Environmental Review Required: YES r f ' '","••DATE OF COMPLETION: , Item Incomplete - Needs your action NO TYPE -.Compliance with condition's' of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. _ PROJECT NO. YES NO TYPE DATE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES_ CA Coastal Commission Authority? YES N0_ NO If California Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite' 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): ' V Coastal Permit Determination Form already completed? If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: ________ YES NO Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans), 2) Complete Coastal Permit Determination Log as needed. H:\ADMIN\COUNTER\BldgPlnchkRevChklst I I II. Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO •,;V ,(A/P/Ds,?Activity"Maintenance, enter CB#, toolbar, Screens, Housingi'Fees, Construct Housing Y/N, Enter Fee, UPDATE!) •I i . i >,i ; ti.t-wt * — -' •»••'• ' . ., *, Site Plan: s\ '/:v. - r? :..' ';V | | 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing ' street improvements, right-of-way width, dimensional setbacks and existing topographical lines. | | | I 2. Provide legal description of property and assessor's parcel number. Zoning: XI 1 • Setbacks: Front: Interior Side: Street Side: Rear: Required ZO Required ± 1 ' Required X Required 14' XI | | I I 2. Accessory structure setbacks: Front: Required Interior Side: Street Side: Rear: Structure separation: 2 C] ED 3. Lot Coverage: SDH]4- He'9ht: :\ XI 5. Parking: Spacesr Guest Spaces AJ I I Additional Comments Required Required Required Required Required ^ 4Oe/o Required £ ^O Required 2. Required Shown ^'l Shown c\/ Shown X, Shown ^\' " \ Shown Shown Shown Shown Shown Shown llpVo n l ' • Shown 2~ Shown t . "" OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H:\ADMIN\COUNTER\BldgPlnchkRevChklst //'?- Section 0 2000.Nov.09 13:24 ][ ][ project: Elliot SFR Addition ][• Edward W. Marshall, P.E. ] 2044 Wildhorse Lane, Big Bear City CA 92314-9024 800.337.7083 * 909.584.1190 * Fax 815.327.9145 (c) 2000 E W Marshall Lateral Design Segment Table of Contents: SECTION DESCRIPTION 1 Shear panel & holddown summary. 2 Diaphragm, reliability factor, & line of force details. 3 Shear panel detail, wind & EQ forces. 4 Input data file. 5 Shear schedule, tie down reference tables. [ ][ ][ ]Project: Elliot SFR Addition [ ][ Edward W. Marshall, P.E. [ ] 2044 Wildhorse Lane, Big Bear City CA 92314-9024 800.337.7083 * 909.584.1190 * Fax 815.327.9145 Shear Panel & HD Summary Section 1 2000.Nov.09 13:24 (c) 2000 E W Marshall Length ID Gross Net 1 2 3 4 5 6 6 4 7 5 4 5 .0 .5 .0 .0 .5 .0 6 4 7 5 4 5 .0 .'5 .0 .0 .5 .0 EQ/ Wind Wind 2 Wind 1 Wind Wind Wind Wind 3 Max V ,031 ,523 848 606 545 ,554 Max Shear Uplift Sched 2,189 2,234 275 335 350 2,693 B B A A A E A.B./ [Hold . Mudsill AB 36 /2x HTT16 36/2x HTT16 4ft /OY 48 /2x 24 /3x HTT16 Down Options] ST min ST max Straps STHD8 STHD8 STHD8 STHD8 STHD10 STHD8 MSTC52 MSTC52 MSTC52 Corner Tiedown Combinations COMBOS ID A B Uplift 2,251 [Hold Down Options] AB ST min ST max Straps HTT16 STHD8 STHD8 MSTC52 Section 1 notes: 1. HTT161 is an HTT16 installed on a 2x stud. 2. ST min is for ST straps installed within 1/2" of corner. 3. ST max requires 2 x le minimum from corner. 24" maximum. 4. Simpson Strongwall panel per PFC-5485. 5. Tiedown corner combinations calculated by SPSS method. 6. ID prefix key: None Shear panel, typical. Panel not included in calculations. "+" Steel or concrete element. LRFD adjusted. Design calculations for element included in main body of structural calculations. [ ][ ][ ]Project: Elliot SFR Addition . Section 2 [ ][ Edward W. Marshall, P.E. ' 2000.Nov.09 13:24 [ ] 2044 Wildhorse Lane, Big Bear City CA 92314-9024 800.337.7083 * 909.584.1190 * Fax 815.327.9145 (c) 2000 E W Marshall Diaphragm Detail Length Wind Exposure OA Gross LOF Sums ID Story N/S E/W N/S E/W Area Weight N/S E/W A 0 12.0 32.0 9.0 12.0 384 9,600 100 100 Reliability Factor Detail (Story Shear)(Max Unit Shear)(Shear Ratio) Story N/S E/W N/S E/W N/S E/W 0 384 384 192 49 5.000 1.286 Reliability factors, N/S = 1.500 E/W = 1.206 (See notes below) Line of Force Detail Alignment Net Panel Shear Shear ID Story Accel. N/S E/W Avail Wind EQ 1 0 20.0% 0% 100% 16.5 1,999 1,920 2 0 20.0% 100% 0% 10.5 3,554 960 3 0 20.0% 100% 0% 5.0 3,554 960 Section 2 notes: 1. Reliabilility/Redundacy factor calculated per 1997 UBC Section 1630. See formula (30-3), Sec 1630.1.1. Refer to Sec. 1628 for notations. [ ][ ][ ]Project: Elliot SFR Addition [ ][ Edward;W. Marshall, P.E. [ ] 2044 Wildhorse Lane, Big Bear City CA 92314-9024 800.337.7083 * 909.584.1190 * Fax 815.327.9145 Shear panel Detail, Wind Section 3 2000.Nov.09 13:24 (c) 2000 E W Marshall Length ID Gross Net 1 6.0 2 4.5 3 7.0 4 5.0 5 4.5 6 5.0 6.0 4.5 7.0 5.0 4.5 5.0 Pier Level LOF Hgt. 0 0 0 0 0 0 Shear panel Detail, 1 6.0 2 4.5 3 7.0 4 5.0 5 4.5 6 5.0 6.0 4.5 7.0 5.0 4.5 5.0 0 0 0 0 0 0 2 2 1 1 1 3 7.0 7.0 4.0 4.0 4.0 4.0 Unit V 338 338 121 121 121 711 Vert. plf 60 60 60 60 60 ' 60 OT 14,216 10,662 3,392 2,423 2,181 14,216 RM 1,080 608 1 ,470 750 608 750 Net OT 13,136 10,054 1,922 1,673 1 ,573 13,466 Solo Composite Uplift Uplift 2,189 2,234 275 335 350 2,693 2,189 2,234 275 335 350 2,693 Earthquake 2 2 1 1 1 3 7.0 7.0 4.0 4.0 4.0 4.0 98 98 100 100 100 206 60 60 60 60 60 60 4,114 3,086 2,807 2,005 1 ,804 4,114 1,080 608 1 ,470 750 608 750 3,034 2,478 1,337 1,255 1,197 3,364 506 551 191 251 266 673 506 551 191 251 266 673 [ ][ ][ ]Project: Elliot SFR Addition [ ][ Edward W. Marshall, P.E. [ ] 2044 Wildhorse Lane, Big Bear City CA 92314-9024 800.337.7083 * 909.584.1190 * Fax 815.327.9145 Input Data Section 4 2000.Nov.09 13:24 (c) 2000 E W Marshall SFR Addition Initial floorplan, DW 25 Snow 0 #### Project Data Project: Elliot Run Description #### Diaphragm Data ID Level A 0 #### Diaphragm Wind Integration Data Parent %,ID (%,ID...) A 100,A #### Diaphragm Ed Integration Data Parent % ID (%,ID.. A 100,A #### revised 11/09/2000 13:14 Wind 18.51 NSLeng 12 EWLeng 32 Plate 8 NSWind 9 EWWind 12 Line of Force LOF 1 2 3 #### Panel Panel 1 2 3 4 5 6 #### Corner ID A #### End of NS% 0 100 100 Data LOF 2 2 1 1 1 3 Tiedown Panel 2 File Data EW% 100 0 0 Length 6 4.5 7 5 4.5 5 V/W 20 20 20 PLateH 8 8 8 8 8 8 %,ID 100, A 50, A 50, A Voids 0 0 0 0 0 0 (%,ID PierH 7 7 4 4 4 4 Combinations A Panel B 3 WVert 60 60 60 60 60 60 EVert 60 60 60 60 60 60 t ][[ ][[ ] ][ JProject: Elliot SFR Addition Edward W. Marshall, P.E. 2044 Wildhorse Lane, Big Bear City CA 92314-9024 800.337.7083 * 909.584.1190 * Fax 815.327.9145 Section 5 2000.Nov.09 13:24 (c) 2000 E W Marshall Shear Schedule, Tie Down Table revised 25 September, 2000 15:35 Allowable Shear for Wind or Seismic Forces, Structural I Panels, Table 23-II-I-1 Values, 1997 UBC (notes 1, 2, 3) Panel Callout A B C D E F D-D E-E F-F 15/32" APA Min. Mudsill LTP4/A35 Shear Struct. I /Framing at 5/8" A.B. Std/H1 Sill Nailing Vmax Sheathing Panel edges (note 4) (note 5) 16d 280 350 430 550 730 870 1,100 1,460 1,740 8d* 8d* 8d* 8d* 8d* 10d 8d* 8d* 10d * Use -6 -4 -4 -3 -2 -2 -3 -2 -2 "o, "0, "0. "0, "0, "0. "o "0 "0 •10d .0. .c. .c. .c. ,c. .c . .c. .c. .c . (6) (6) (6) (6) (6) ,(6) (6) fasteners 2x 2x 3x 3x 3x 3x 3x 3x 3x over 48 36 36 32 24 18 16 (6) 12 (6) 9 (6) G.W.B. 18/48 16/48 12/24 9/16 7/10 6/ 8 9/16 (7) 7/10 (7) 6/ 8 (7) 8 5 5 4 3 3 4 3 3 (8) (8) (8) NOTES: 1. panel edges blocked with min. 2"-nominal or wider framing, 16" stud spacing, common, not sinker, nails or galv. box nails. 2. 5/8" T1-11 nailed through 5/8" section may be used. 3. 12" o.c. spacing in field, typical all callouts. 4. 2 x 2 x 3/16 plate washers are required at all anchor bolts. 5. One each (1) H1 seismic tie required at each truss. 6. Staggered. 7. Both sides of panel. 8. (2) rows at table spacing. Double blocking/double rim. Allowable Tension, Simpson StrongTie Holddowns, Straps, Catalog C-99 (1, 2, 3) Anchor Threaded T max Holdown Stud Bolt CL SO Rod T max Strap Stud 1,656 3,480 4,565 5,585 7,120 8,910 11 ,080 15,305 HTT161 HTT16 HTT22 PHD6 PHD8 HD10a HD143 (5) HD15 (5,6) 2x 4x 4X 4X 4x 4x 4x 6x SSTB20 SSTB20 SSTB24 SSTB28 SSTB28 SSTB28 1 x 42 1-1/4 x 44 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 2-1/16 2-3/16 2-1/8 1/2 1/2 1/2 1-5/8 1-5/8 9/-16 5/8 3-5/8 (4) (4) (4) 5/8 5/8 5/8 7/8 7/8 7/8 1 1-1/4 1 2 3 5 5 ,000 ,145 ,375 ,035 ,855 LSTA36 MSTC40 MSTC52 MSTC66 MSTC78 2x 4x 4x 4x 4x NOTES: 1. See Simpson StrongTie Catalog for manufacturer's written instructions. 2. Washers are required under stud bolt nuts. 3. SO = Min. plate standoff height, CL = Stud face to bolt centerline. 4. Estimated. 5. 36" minimum embedment. 6. HD15 requires standard washer between base plate and,nut. Certificate of Compliance: Residential CF-1R Elliot Addition [ Project Title '465 Chestnut Avenue, bate lQ/24/00 Carlsbad Project Address DELL CO. ; ; ; Documentation Author Package D__ Compliance Method (Package or Computer) (760}. 940=0064.. Telephone 7 Climate Zone Building Permit # Plan Check / Date Field Check / Dote Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 352 _sg.ft. Building Type: (check one or more) Single Family Detached (SFD)[X] Addition Alone __ Single Family Attached (SFA) EU Existing Building Lj Multi-Family [j Existing Plus Addition ALLOWED GLAZING 352 X 20%REMOVED GU\ZING 5050(25) TOTAL ALLOWED PROPOSED GLAZING 2-2x2(8)+ 6040(24) +2-5040(40)+3014(4) = 70.4sq.ft. = 25.0sq.ft. = 95.4sq.ft. = 76.0sq.ft. Front Orientation: _Sojjth__ Number of Dwelling Units: BUILDING SHELL INSULATION Component Type /?-30 Roof 1.00 Floor Construction Type:- Slab on Grade Const. Assembly U-Value 0.035 Location/Comments (attic, to garage, typical, etc.) Addition R-13 Exterior Wall 0.088 Addition FENESTRATiON Fenestration Orientation Shading Devices Area Fenestration Interior Exterior Overhang Side Fins Framing (SF) U-Value SHGR (roller blind.etc.) (shadescreen.etc.) Yes/No Yes/No Type '. D LI D D 44 24 0.75 0.75 8 QJS NR Standard Drape NR Standard Drape ..MR... it/A : Standard Bug Screen ! j [Xj QStandard Bug Screen l_j (Xj• h n N/A i : :... U LJ_ n n mil ML THERMAL MASS Type/Covering (slab/tile, etc.) NR Exposed Yes/Noa aa a Area (SF) LJ Thickness (inches)Location / Description (kitchen, bath, etc.)