Loading...
HomeMy WebLinkAbout1475 CHESTNUT AVE; ; CB022298; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Retaining Wall Permit Permit No: CB022298 Building Inspection Request Line (760) 602-2725 " Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: 1475 CHESTNUT AV CBAD RETAIN 2052207400 Lot #: $3,150.00 Construction Type: 0 NEW BAINES RES-200 SF RETAIN WALL PER CITY STANDARD-LEVEL BACKFILL Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 08/08/2002 RMA 08/20/2002 08/20/2002 4185 08/20/02 0002 01 02 Applicant: MOORE, JOE 3612 VALLEY ST CARLSBAD, CA 92008 619-434-1203 Owner: ALLEN-BAINES REX V&DIANE C 1475 CHESTNUT AVE CARLSBAD CA 92008 89 = 26 Total Fees:$89.26 Total Payments To Date:$0.00 Balance Due:$89.26 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee ' Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $53.49 $0.00 $34.77 $0.00 $1.00 $0.00 $0.00 $0.00 $0.00 $89.26 Inspect Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 ROJECT FOR OFFICE USE ONLY PLAN CHECK NO.ffi/9 '3&2QP *~*1 / /"""" *\ ^^ EST. VAL. J / -3 U Plan Ck. Deposit - Validated By / / /£ Date C/7.P//7J Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use Proposed Use Description of Work i 2,op J?T H 2. • CONTACT PERSON (if different from a SO. FT.#of Stories # of Bedrooms # of Bathrooms i—_—ft? ^_ — Name _ \~f-^ f "LG)C>f&C. Address ' City ,4;.'' APPLICANT [p-CBntractor Q Agent for Contractor C3 Owner Q Agent for Owner State/Zip Telephone ff Fax # Name ;4V i PROPERTY OWNER Address Telephon* Addresss , ' City State/Zip Telephone #Name :BlV "CttNTBACTO'RV COMPAN Y"NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penatty of not mere than five hundred dollars [S500H. Name State License t Address License Class City State/Zip Telephone # City Business License </3zi f~i( f Designer Name Address City State/Zip Telephone State License # ;«. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ; n I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date__ (THJS-9ECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) t\ CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. , . ' WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($JjUM}tT5)7Nri addition to the cost of compensation, damages as provided for in Section 3706 of the Labbr codeC interest and attorney's fees. SIGNATURE ^^^^X^^^^^-gC DATE c5( <f~/ <3 ^ 7,,v OWNER-BU&DER DECLARATION ~' 1 hereby affirm that I am exempt from the Contractor's License Law for the following reason: CD I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does • such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). l~l I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with'contractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section ' Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. [H YES C]NO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): • PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? fj] YES d NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? l~l YES l~l NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. $. CO'NSitRUCTIQK LENDING AGENCY . I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS •9. " APPLICANT CERTIFICATION , I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit to suspended or abandoned at any time after the work is copjieoeed^ief-a period of 180 days (Section 106.4.4 Uniform Building Code)! * APPLICANT'S SIGNATURE ^~~~—^^^^^t^>7^^ DATE ^ WHITE: File YELLOW: Applicant PINK: Finance Inspection List Permit#: CB022298 Type: RETAIN BAINES RES-200 SF RETAIN WALL PER CITY STANDARD-LEVEL BACKFILL Date Inspection Item Inspector Act Comments 10/29/200269 Final Masonry PD AP FTG & WALL STEEL HAD BEEN EXPOSED-GUARD RAILS AND HAND RAILS INSTALLED 08/28/200211 Ftg/Foundation/Piers PD NR 08/28/200217 Interior Lath/Drywall PD WC Tuesday, October 29,2002 • Page 1 of 1 UNSCHEDULED BUILDING INSPECTION DATF. 0-24~-0 2- INSPECTOR PF.KMTTfl '0 PLAN CHECK # JOB DESCRIPTION CODE DESCRIPTION ----- ~~ — - ACT $ CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE LOCATION. PERMIT NO. (760) 602-2700 1635 FARADAY AVENUE TIME /, a &* .3.3,> A ' ' ,s. g.5" VV ff«* fr. 3) A>t # S .egW ir i v/ / . i* FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? I ) YES FOB FURTHEB.JNEQBMAI1ON. QONTACT/y/ ^4 PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER City of Carlsbad Public Works — Engineering BUILDING PLANCHECK CHECKLIST RETAINING WALL BUILDING PLANCHECK NUMBER: CB BUILDING ADDRESS: PROJECT DESCRIPTION: Retaining Wall ASSESSOR'S PARCEL NUMBER: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this repgrt can^ resultjin ^suspension ofpermitto btf~ Date: DENIAL Please see^tne attached report of deficiencies marked wjm D. /Make necessary corrections to plans 'ft s^cifications for compliance with applicaBJe-eoaes and standards. Submit corrected plans and/or specifications to this office for review. ATTACHMENTS D Right-of-Way Permit Application ENGINEERING DEPT. CONTACT PERSON NAME: Karen City of Carlsbad ADDRESS: 1 635 Faraday Ave Carlsbad, CA 92008 PHONE:(760) 602-2775 H:\Development Services\MASTERS\FORMS -VCHECKLISTS -\BUILDING PLANCHECK CKLIST FORM - RETAINING WALLS.doc 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562 BUILDING PLANCHECK CHECKLIST RETAINING WALLS 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow £ Existing & Proposed Structures / (dimensioned from street) Property Lines 2. Show on site plan: Drainage Patterns ! Existing & Proposed Slopes . Existing Topography 3. Include on title sheet: . Site Address ' Assessor's Parcel Number C-yLegal Description \) Grading Quantities Cut basements .etaining Wall — (location and height} ( Import/Export (Grading Permit and Haul Route Permit may be required) o-v o^rVo ^Xas^i^ <X/-e~ CA/O-V^ Oc^t\vji-^v^ 4. Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by:Date: Q MISCELLANEOUS PERMITS Q 5. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. A separate Right-of-Way issued by the Engineering Department is required for the following: ' Please obtain an application for Right-of-Way permit from the Engineering Department. Page 1 H:\0evelopment Services\MASTERS\FORMS -\CHECKUSTS -BUILDING PLANCHECK CKLIST FORM - RETAINING WALLS.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB DATE - QQ ADDRESS RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR « $10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE OTHER COMPLETE OFFICE BUILDING PLANNER DATE ENGINEER DATE Docs/Misforms/planning Engineering Approvals flv> \ ^llp° Ift June 2001 *City of San Diego •Information Bulletin 221 Page 3 of 4 Figure 1/Type III or IV retaining wall with level backfill Concrete block Level backfill Horizontal steel (See Section VIII for applications) Wall thickness 6" for Type III wall 8" for Type IV wall "A" bars 40-bar-diameter lap minimum Gravel backfill 12^ wide Mortar key (See Section V) 12" minimum concrete depth, 12" minimum into natural ground or approved compacted fill Note: A minimum of 7 feet must be provided horizontally from the toe of the footing to daylight where the ground slopes away form the base of the wall. \ Page 2 of4 City of San Diego • Information Bulletin 221 June 2001 VI. WALL DRAINS Wall drains (four-inch-diameter) must be placed at 6-foot intervals along the length of the wall and lo- cated just above the level of the soil or paving on the front face of the wall. The drains may be formed by placing a block on its side at 6-foot intervals, by leav- ing out the mortar in the vertical spaces between all the blocks in the first course above the soil or paving (head joint) on the front face of the wall or by any other acceptable equivalent method. Backfill behind wall drains or open head joints must be loose rubble or gravel 12 inches wide and extending from the top of the wall to the top of the footing. vn. SOIL Wall design, footing sizes, and reinforcing steel are all based on an active earth pressure with an equiva- lent fluid weight of 30 pounds per cubic foot. All foot- ings must extend at least 12 inches into undisturbed natural soil or compacted fill which has been com- pacted to at least 90 percent density. Soil should be dampened prior to placing concrete in footings. A soils report, compiled by a licensed civil engineer, may be required. A minimum of 7 feet must be provided horizontally from the toe of the footing to daylight where the ground slopes away from the base of the wall. Footing sizes given in Table A are based on a 1,000 psf maximum soil bearing value; use of a larger bear- ing value will require design by a licensed architect or civil engineer specifically for the existing conditions. A soils report, compiled by a licensed civil engineer, may be required. VI. REINFORCING STEEL Reinforcing steel must be deformed and comply with ASTM specification A615-85, Grade 40 or 60. When one continuous bar cannot be used, a lap or spice of 40-bar diameters is required. Two #3 bars must be placed longitudinally in the footing as shown in figures 1 and 2. For 6-inch or 8-inch blocks, one #3 reinforcing bar must be placed longitudinally in the center of the wall in a bond beam block every 16 inches as the blocks are laid up. For 12-inch blocks, one #4 reinforcing bar must be placed longitudinally in the center of the wall in a bond beam block every 16 inches as the blocks are laid up. Table A/Requirements for Various Wall Heights '•" Wall Height (H) V-4" 2'-0° 2'-8" 3'-4" 4'-0" 4'-8" 5'-4" 6'-0" 6'-8" T-4" 8'-0" Wall Type III III III III IV IV IV V V V V Toe Dimension (L) 2" 2" 3" 4" 6? 11" 12" 16" 16" 16" 20" Footing Width (W) 1'- 3" 1'- 6" 1'-10" 2- 1" 2'- 6" 2'-11" 31- 2" 3'-10" 4'- 4" 5'- 0" 51- 8" Key Size (K) None None None None None None 6"x 6" 8"x 8" 8"X 8" 12"x12" 12"x12" "A" Bars #3s @ 24" o.c. #3s @ 24" o.c. #3s@24"o.c. #3s @ 24" O.C. #4s @ 24" o.c. #4s @ 24" O.C. #4s @ 16" o.c. #4s@16"o.C. #4s@16"o.c. #5s@16"o.c. #6s@16"o.c. "B" Bars None None #3s @ 48" o.c. #3s @ 48" o.c. #3s @ 32" o.c. #4S @ 24" O.C. #4s @ 24" o.c. #4S @ 24" O.C. #4s @ 16" o.c. #4s@ 16"O.C. #4S @ 16" O.C. Footnotes1 Footing sizes are based on 1,000 psf maximum soil bearing value. The resultant is within the middle third of the footing. 1 Wall not shown in Table A above must be designed specifically for the actual condition.1 All construction must comply with the specifications shown in this information bulletin. 4 When Wall Type V is required, the first 32 inches of block, regardless of wall height, must be 12-inch-wide masonry units.