Residential Permit Permit No:CB992376
Building Inspection Request Line (760)438-3101
Job Address:1480 CHESTNUT AV CBAD
Permit Type: RESDNTL
Parcel No: 2051307800
Valuation: $239,875.50
Occupancy Group: 6
# Dwelling Units: 1
Bedrooms: 4
Project Title: CARLSBAD 4
Sub Type: SFD
Lot #: 1
Construction Type: VN
Reference #: MS 851
Structure Type: SFD
Bathrooms: 2.5
Status:
Applied:
Entered By:
Issued:
Inspect Area:
Orig PC#:
06/07/1999
DT
Plan Approved:
PC990084
PLAN 1 NEW SFD 2720SF LIV.720SF GAR.38SF PORCHPIan Check#:
Applicant:
BRUCE D WIEGAND INC
1060WIEGANDST
OLIVNHAIN CA 92024
619-759-0970
Owner:
-WIEGAND-NEGLIA CORP
6N19-759-09ZOl £
Total Fees: $19,613.41 / cTotal Payments'to'Date:/ -f,,- \~vs-—X. \ if* y I/ ts \ i-\
0 Balance Due: $19,613.41
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
PLUMBING'TOTAL
$0.00 ^~~ECEdTRICAL TOTAL
$0.00 MECHANICAL TOTAL
$0.00 Housing Impact Fee
$3,420.00 Housing InLieu Fee
D3/4 Master Drainage Fee:
$0.00 Sewer Fee:
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$4,365.73
$4,029.91
$0.00
$0.00
$409.00
$461.00
$0.00
$0.00
$175.00
$60.00
$56.50
$2,925.00
$0.00
$0.00
$1,854.00
$19,613.41
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161
City of Carlsbad
Final Building Inspection JUL20
Dept: Building (Engirjee'ririg Planning CMWD St Lite Fire
Plan Check #:
Permit#:
Project Name:
Address:
Contact Person:
Sewer Dist:
Date:7/20/2000
CB992376
CARLSBAD 4
PLAN 1 NEW SFD 2720SF LIV.720SF GAR.38SF PORCH
1480 CHESTNUT AV ' Lot:
BART Phone: 8587590970
CA Water Dist: CA
Permit Type: RESDNTL
Sub Type: SFD
Inspected
By
Inspected
By:_
Inspected
By:
Date
Inspected:
Date
Inspected:
Date
Inspected:
Approved:
Approved:
Approved:
Disapproved:
Disapproved:
Disapproved:
Comments:
City of Carlsbad Bldg Inspection Request
For: 9/14/2000
Permit* CB992376
Title: CARLSBAD 4
Description: PLAN 1 NEW SFD 2720SF LIV.720SF GAR.38SF PORCH
Inspector Assignment: PD
1480 CHESTNUT AV
Lot 1
Type: RESDNTL
Job Address:
Suite:
Location:
APPLICANT BRUCE D WIEGAND INC
Owner: WIEGAND NEGLIA CORP
Remarks:
Sub Type: SFD
Phone: 8587590970
Inspector:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By: BART
Entered By: CHRISTINE
Act Comments
v
Associated PCRs
Inspection History
Date
7/20/2000
1/19/2000
1/7/2000
1/5/2000
1/5/2000
1/5/2000
12/23/1999
12/22/1999
12/20/1999
12/20/1999
12/20/1999
12/20/1999
11/30/1999
11/29/1999
11/29/1999
11/23/1999
Description
89 Final Combo
17 Interior Lath/Drywall
82 Drywall/Ext Lath/Gas Test
17 Interior Lath/Drywall
18 Exterior Lath/Drywall
23 Gas/Test/Repairs
14 Frame/Steel/Bolting/Welding
22 Sewer/Water Service
14 Frame/Steel/Bolting/Welding
24 Rough/Topout
34 Rough Electric
44 Rough/Ducts/Dampers
83 Roof Sheathing/Ext Shear
13 Shear Panels/HD's
15Roof/Reroof
83 Roof Sheathing/Ext Shear
Act
CO
AP
AP
PA
NR
AP
AP
CO
CO
AP
AP
AP
AP
NR
NR
NR
Insp
SR
PD
PD
PD
PD
PD
SR
SR
SR
SR
SR
SR
SR
SR
SR
SR
Comments
LIST OF CORRECTIONS ON THE JOB SITE
SHOWER
OK TO HANG 2ND LAYER IN GARAGE
ALL CORRECTIONS MADE
NO ONE ON THE JOB SITE (PLUMBER)
LIST OF CORRECTIONS ON JOB SITE
City of Carlsbad Bldg Inspection Request
For: 9/13/2000
Permit# CB992376
Title: CARLSBAD 4
Description: PLAN 1 NEW SFD 2720SF LIV.720SF GAR.38SF PORCH
Inspector Assignment: PD
Type:RESDNTL Sub Type: SFD
Job Address: 1480 CHESTNUT AV
Suite: Lot 1
Location:
APPLICANT BRUCE D WIEGAND INC
Owner: WIEGAND NEGLIA CORP
Remarks:
Phone: 8587590970
Inspector:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By: BART
Entered By: CHRISTINE
Act Comments
G-Kt
Associated PCRs
Inspection History
Date
7/20/2000
1/19/2000
1/7/2000
1/5/2000
1/5/2000
1/5/2000
12/23/1999
12/22/1999
12/20/1999
12/20/1999
12/20/1999
12/20/1999
11/30/1999
11/29/1999
11/29/1999
11/23/1999
Description
89 Final Combo
17 Interior Lath/Drywall
82 Drywall/Ext Lath/Gas Test
17 Interior Lath/Drywall
18 Exterior Lath/Drywall
23 Gas/Test/Repairs
14 Frame/Steel/Bolting/Welding
22 Sewer/Water Service
14 Frame/Steel/Bolting/Welding
24 Rough/Topout
34 Rough Electric
44 Rough/Ducts/Dampers
83 Roof Sheathing/Ext Shear
13 Shear Panels/HD's
15Roof/Reroof
83 Roof Sheathing/Ext Shear
Act
CO
AP
AP
PA
NR
AP
AP
CO
CO
AP
AP
AP
AP
NR
NR
NR
Insp
SR
PD
PD
PD
PD
PD
SR
SR
SR
SR
SR
SR
SR
SR
SR
SR
Comments
LIST OF CORRECTIONS ON THE JOB SITE
SHOWER
OK TO HANG 2ND LAYER IN GARAGE
ALL CORRECTIONS MADE
NO ONE ON THE JOB SITE (PLUMBER)
LIST OF CORRECTIONS ON JOB SITE
City of Carlsbad Inspection Request
For: 1/5/2000
Permit# CB992376
Title: CARLSBAD 4
Description: PLAN 1 NEWSFD 2720SF LIVJ20SF GAR,38SF PORCH
Inspector Assignment: SR
1480 CHESTNUT AV
Lot 1
Type:RESDNTL Sub Type: SFD
Job Address:
Suite:
Location:
APPLICANT BRUCE D WIEGAND INC
Owner: WIEGAND NEGLIA CORP
Remarks:
Phone: 6193395930
Inspector:
Total Time:Requested By: BRUCE
Entered By: CHRISTINE
CD Description
17 Interior Lath/Dry wall
18 Exterior Lath/Drywall
Act Comments
TO
MR.
Associated PCRs
Inspection History
Date
12/23/1999
12/22/1999
12/20/1999
12/20/1999
12/20/1999
12/20/1999
11/30/1999
11/29/1999
11/29/1999
11/23/1999
11/22/1999
10/8/1999
10/1/1999
9/23/1999
Description
14 Frame/Steel/Bolting/Welding
22 Sewer/Water Service
14 Frame/Steel/Bolting/Welding
24 Rough/Topout
34 Rough Electric
44 Rough/Ducts/Dampers
83 Roof Sheathing/Ext Shear
13 Shear Panels/HD's
15Roof/Reroof
83 Roof Sheathing/Ext Shear
83 Roof Sheathing/Ext Shear
39 Final Electrical
1 1 Ftg/Foundation/Piers
21 Underground/Under Floor
Act
AP
CO
CO
AP
AP
AP
AP
NR
NR
NR
NR
AP
AP
AP
Insp
SR
SR
SR
SR
.SR
SR
SR
SR
SR
SR
SR
SR
SR
SR
Comments
ALL CORRECTIONS MADE
NO ONE ON THE JOB SITE (PLUMBER)
LIST OF CORRECTIONS ON JOB SITE
NEED SPECIAL INSPR NOTES ON STRONG WALLS
BANKER INSULATION
OF CALIFORNIA, INC.
2337 Vineyard Ave.
Escondido, CA 92029
License #552601
THIS IS TO CERTIFY THAT INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH
CURRENT ENERGY REGULATIONS, CALIFORNIA ADMINISTRATIVE CODE, TITLE 24,
STATE OF CALIFORNIA, IN THE BUILDING LOCATED AT:
Wiegnad Neglia Corp. LOT#..TRACT#.
Chestnut Avenue CITY Carl CA .
EXTERIOR WALLS:
MANUFACTURER Certainteed
CEILINGS:
BATTS:
MANUFACTURER
BLOWN IN:
MANUFACTURER .
Certainteed
R-
. THICKNESSm'PE 3« ^0 VALUE .
.THICKNESS/TYPE
10 R- 30.VALUE
MINIMUM
.THICKNESS.
R-
.VALUE.
SQUARE FOOTAGE COVERED „ _ . , . NJJMBER.OF BAGS USEDToam seleant per "Title 24" air infil-
tration requirements.
THICKNESS/TYPE 3* 50
bags per
1000 square feet
FLOORS:
MANUFACTURER Certainteed
SLAB ON GRADE:
MANUFACTURER
R-
. VALUE
WIDTH OF INSULATION.
FOUNDATION WALLS:
MANUFACTURER
. THICKNESSm'PE .
INCHES
R-
.VALUE.
. THICKNESSATYPE
R-
.VALUE.
GENERAL CONTRACTOR .
CALIFORNIA CONTRACTORS LICENSE#_.DATE.
SIGNATURE TITLE
INSULATION CONTRACTOR — BANKER INSULATION OF CALIFORNIA, INC.
CALIFORNIA CONTRACTORS LICENSE # 552601
DATE 12/22/99
Contract Secretary
SIGNATURE TITLE
City of Carlsbad Inspection Request
For: 10/8/99
Permit# CB992376
Title: CARLSBAD 4
Description: PLAN 1 NEWSFD 2720SF LIV,720SF GAR.38SF PORCH
Inspector Assignment: SR
1480 CHESTNUT AV
Lot 1
Type:RESDNTL Sub Type: SFD
Job Address:
Suite:
Location:
APPLICANT BRUCE D WIEGAND INC
Owner:
Remarks: T.S.P.B
Phone: 8587590970
Inspector:
Total Time:
CD Description
39 Final Electrical
Act Comments
Requested By: BART
Entered By: CHRISTINE
Inspection History
Date Description Act Insp Comments
10/1/99 11 Ftg/Foundation/Piers AP SR NEED SPECIAL INSPR NOTES ON STRONG WALLS
9/23/99 21 Underground/Under Floor AP SR
City of Carlsbad Inspection Request
For: 10/1/99
Permit* CB992376
Title: CARLSBAD 4
Description: PLAN 1 NEW SFD 2720SF LIV.720SF GAR.38SF PORCH
Inspector Assignment: SR
Type:RESDNTL Sub Type: SFD
Job Address: 1480 CHESTNUT AV
Suite: ' Lot 1
Location:
APPLICANT BRUCE D WIEGAND INC
Owner:
9Remarks:
Phone: 6192295930
Inspector:
Total Time:
CD Description
1 Ftg/Foundation/Piers
Act Comments
Requested By: BRUCE
Entered By: CHRISTINE
Inspection History
Date Description Act Insp Comments
9/23/99 21 Underground/Under Floor AP SR
Geotet-nnics
Incorporated
o 9951 Business Park Ave., Suite B
San Diego, California 92131
Phone (619) 536-1000
_ Fax (619) 536-8311
FIELD MEMO
DATE ^PAGE \ OF I
PROJECT NO.:
CLIENT:
MEMO
SUBJECT:>^--s- i t "4 6=O , t
U
Trig? "FegnrnOGn'S. x*-?^^ GSx-cr^^^^-T"^^
TTJr<3~
GEOTECHNICS INCORPORATED, BY:
(SIGNATtlRE)
engineering file: white copy job superintendent: yellow copy field file: pink copy
1476
CHFUSTIAN WHEELER
ENGINEERING
COMPRESSIVE STRENGTH TEST RESULTS
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Date Received:
Sampled by:
Tested by:
Sample Type:
Carlsbad #1400
1480 Chestnut Ave., Carlsbad
Wiegand Construction
Lot 1
2500 psi
10-6-99
10-7-99
AC
TP
Concrete, 6" x 12"
Job#:
Permit #:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck #:
Mix Temp:
Slump:
Min in Mixer:
199.532
CB992376 Plan File #:
Case Group Architects
MCB/Gouvis Engineering
Superior
35P
Pozz
407 Ticket #: 259440
Air Temp:
4'/2" %Air:
49 UnitWt:
Sample #
2976
2977
2978
Date Tested
10-13-99
11-3-99
11-3-99
Age (days)
7
28
28
Area (sq. inches)
28.27
28.46
" 28.46
Maximum Load
(Ibs)
82,820
122,050
116,300
Comp. Strength
(psi)
2,930
4,290
4,090
Failure Type
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering in accordance with the applicable ASTM standards. No
other warranties express or implied.
Distribution:
(2) Wiegand Neglia Corp.
(1) City of Carlsbad
Reviewed by:
Michael B. Wheeler, RCE #45358
4925 Mercury Street + San Diego, CA 92111 + 858-496-9760 + FAX 858-496-9758
CHRJSTIAN WHEELER.
ENGINEERING
DAILY REPORT
Project Name Carlsbad #1400 Project #199.532 DR#Page lofl
Project Address See below Permit #See below Plan File #
Contractor
Weigand Neglia Construction
Architect
Case Group Architects
Subcontractor
Davidson Engineer Davidson
Date
10-14-99
Stephen W.
Campbell
#206
Pre-stressed Concrete
Tendons: A416, 270 ksi
Gauge: #99480
Lot Plan Address Permit
1 1A 1480 Chestnut Ave. 992376
2 IB 1450 Chestnut Ave. 992377
3 2A 1460 Chestnut Ave. 992386
4 2B 1470 Chestnut Ave. 992387
Performed continuous special inspection during the tensioning of tendons for the listed lots. Observed gauge pressures and recorded
elongations. To the best of my knowledge, tensioning performed this date is in substantial conformance.
Unless noted otherwise, the work observed is, to the best of my knowledge, in compliance with the approved plans and specifications.
Distribution:
(2) Wiegand Neglia Corp
(1) City of Carlsbad
Reviewed by Michael B. Wheeler, R.C.E. #45358
4925 Mercury Street + San Diego, CA 92111 +.858-496-9760 + FAX 858-496-9758
CHRISTIAN WHEELER.
ENGINEERING
COMPRESSIVE STRENGTH TEST RESULTS
Job Name:
Job Address:
Contractor:
Subcontractor:
Carlsbad #1400
1450 Chestnut Ave., Carlsbad
Wiegand Construction
Job#: 199.532
Permit*: CB992377 Plan File#:
Architect: Case Group Architects
Engineer: MCB/Gouvis Engineering
Test Location: Lot 2
Req. Strength: 4000 psi
Date Sampled: 10-5-99
Date Received: 10-6-99
Sampled by: AC
Tested by: TP
Sample Type: Concrete, 6" x 12"
Supplier: Escondido Ready Mix
Mix#: 365P
Admixture(s): Pozz
Truck*: 384 Ticket*: 259388
Mix Temp: Air Temp:
Slump: 4'/2" • %Air:
Win in Mixer. 51 UnitWt:
Sample #
2966
2967
2968
Date Tested
10-13-99
11-2-99
11-2-99
Age (days)
8
28
28
Area (sq. inches)
28.27
28.27
28.27
Maximum Load
, (Ibs)
119,130
150,230
142,370
Comp. Strength
(psi)
4,210-
5,310
5,040
Failure Type
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering in accordance with the applicable ASTM standards. No
other warranties express or implied. ' . • •
Distribution:
(2) Wiegand Neglia Corp.
(1) City of Carlsbad
Reviewed by:
Michael B. Wheeler, RCE #45358
4925 Mercury Street + San Diego, CA 92111 + 858-496-9760 + FAX 858-496-9758
CHRISTIAN WHEELER.
ENGINEERING
DAILY REPORT
Project Name Carlsbad #1400 Project #
199.532
DR#Page
lofl
Project Address See below Permit #
See below
Plan File #
Contractor
Weigand Neglia Construction Architect Case Group Architects
Subcontractor Davidson Engineer Davidson
Date
10-14-99
Stephen W.
Campbell
#206
Pre-stressed Concrete
Tendons: A416, 270 ksi
Gauge: #99480
Lot Plan Address Permit
1 1A 1480 Chestnut Ave. 992376 •
2 IB 1450 Chestnut Aye. 992377
3 2A 1460 Chestnut Ave. 992386
4 2B 1470 Chestnut Ave. 992387
Performed continuous special inspection during the tensioning of tendons for the listed lots. Observed gauge pressures and recorded
elongations. To the best of my knowledge, tensioning performed this date is in substantial conformance.
Unless noted otherwise, the work observed is, to the best of my knowledge, in compliance with the approved plans and specifications.
Distribution:
(2) Wiegand Neglia Corp
(1) City of Carlsbad
Reviewed by Michael B. Wheeler, R.C.E. #45358
4925 Mercury Street + San Diego, CA 92111 -f 858-496-9760 + FAX 858-496-9758
CHRISTIAN WHEELER.
ENGINEERING
COMPRESSIVE STRENGTH TEST RESULTS
Job Name:
Job Address:
Contractor:
Subcontractor:
Carlsbad #1400
1470 Chestnut Ave., Carlsbad
Wiegand Construction
Job#: 199.532
Permit*: CB992387 Plan File#:
Architect: Case Group Architects
Engineer: MCB/Gouvis Engineering
Test Location: Lot 4
Req. Strength: 2500 psi
Date Sampled: 10-6-99
Date Received: 10-7-99
Sampled by: AC
Tested by: TP
Sample Type: Concrete, 6" x 12"
Supplier: Superior
Mix #: 35P
Admixture(s): fozz
Truck #: 407
Mix Temp:
Slump: 5"
Min in Mixer: 46
Ticket*: 259453
Air Temp:
% Air:
UnitWt:
Sample #
2979
2980
2981
Date Tested
- 10-13-99
11-3-99
11-3-99
Age (days)
7
28
28
Area (sq. inches)
28.27
28.46
28.46
Maximum Load
(Ibs)
60,840
96,330
96,920
Comp. Strength
(PSi)
2,150
3,380
3,410
Failure Type
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering in accordance with the applicable ASTM standards. No
other warranties express or implied. .
Distribution:
(2) Wiegand Neglia Corp.
(1) City of Carlsbad
Reviewed by:
Michael B. Wheeler, RCE #45358
4925 Mercury Street -*• San Diego, CA 92111 + 858-49 6-9760. + FAX 858-496-9758
CHRISTIAN WHEELER.
ENGINEERING
DAILY REPORT
Projecf Name
Carlsbad #1400
Project #
199.532
DR#Page
lofl
Project Address
See below
Permit #See below Plan File #
Contractor
Weigand Neglia Construction
Architect
Case Group Architects
Subcontractor
Davidson
Engineer
Davidson
Date
10-14-99
Stephen W.
Campbell
#206
Pre-stressed Concrete
Tendons: A416, 270 ksi
Gauge: #99480
Lot Plan Address Permit
1 1A 1480 Chestnut Ave. 992376
2 IB 1450 Chestnut Ave. 992377
3 2A 1460 Chestnut Ave. 992386
4 2B 1470 Chestnut Ave. 992387
Performed continuous special inspection during die tensioning of tendons for the listed lots. Observed gauge pressures and recorded
elongations. To the best of my knowledge, tensioning performed this date is in substantial conformance.
Unless noted otherwise, the work observed is, to the best of my knowledge, in compliance with the approved plans and specifications.
Distribution:
(2) Wiegand Neglia Corp
(l)City of Carlsbad
Reviewed by Michael B. Wheeler, R.C.E. #45358
4925 Mercury Street + San Diego, CA 92111 + 858-496-9760 + FAX 858-496-9758