HomeMy WebLinkAbout151 HEMLOCK AVE; ; CB940271; PermitB U I L D I N G
04/01/94 10:17
1 Page 1 of 1
Job Address: 151 HEMLOCK AV
Permit Type: RESIDENTAL ADD/ALT
Parcel No: 204-252-18-00
Valuation: 22,695
Construction Type: VN
P E R M I T
Suite:
Lot#:
Permit No: CB940271
Project No: A9400391
Development No:
Occupancy Group: R-3 Reference#: Status: ISSUED
03/15/94
04/01/94
MDP
Description: 225 SF ADDITION ONE STORY
: FAMILY ROOM
Appl/Ownr : CARPENTER, KENDALL
5190 ALAMOSA PARK DRIVE
OCEANSIDE , CA . 92057
*** Fees Required *** ***
Fees:
Adjustments:
Total Fees:
408.00
.oo
408.00
Applied:
Apr/Issue :
619
Entered By:
941-6597
Fees Collected & Credits
Total Credits:
Total Payments:
Balance Due:
.00
152.00
256.00
***
Fee description Units Fee/Unit Ext fee Data
Building Permit
Plan Check
Strong Motion Fee
* BUILDING TOTAL
Enter "Y" for Plumbinq Issue Fee >
Enter 'Y f or Elec tric Issue Fee >
Enter "Y" for Remodel >
A ELELTF CAL TOTAL
Enter 'Y' for Mechanical ~~ue fee>
234.00
152.00
2.00
388.00
10.00
10 .00
20.00
-//T:__APPRC I
IN . ~-DATE: f t·<U(
CLEA1,A vt ______
1
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
N
y
y
N
City of carlsbad Building Departaent
2075 Las Pal..,. Dr., Carlsbad, CA 92009 (619) 438·1161
I. PP1tMI I IYPE
A -U Commercial U New Bmldmg Li I enant Improvement
B -• Industrial LI New Building • Tenant Improvement
~ ~
C -• Residential • Apartment • Condo D Single Family Dwelling -:::,J.Addition/ Alteration
• Duplex • Demolition • Relocation • Mobile Home • Electrical • Plumbing
• Mechanical • Pool • Spa • Retaining Wall • Solar • Other
PLAN CHECK NO. Zl{
2. PROJF.Cr INFORMATION FOR: OFFICE USE ONLY
Address /,5/ ./leJ-<L.oC-K.
Nearest OW. Street
Building or Suite No.
LEGAL DEScRIM ION Lot No. Sulxi.lV1s1on Name/Number Omt No. Phase No.
CHOCK BEWW If SUBMI 11 EU: • 2 Energy Cales • 2 Structural Cales • 2 Soils Report • 1 Addressed Envelope
ASSESSOR'S PARCEL EXISTING USE PROPQSEP USE
DESCRIPTION OF WORK
SQ. FT. Z-s;-s-# OF STORIES ON~
3. WN IACI PERSON (U Olflerent tram applicant)
NAME ADDRESS
CITY °t STATE ZIP CODE DAY TELEPHONE
4. XPPUCANI )ZFUNIRACIOR UACENI FUR WNIRAC10R uuwNntt
NAME ?f~,1\/0_A-U.-~~DRESS s;"/9o ,,;k,~~
CITY O / Sf O , STATE /_,I/ ZIP CODE '9 3c:JS:-7DAY TELEPHONE
CITY ~~.-$a.:'./ STATE CA• ZIP CODE DAY TELEPHONE
CITY STATE ZIP CODE DAYTELEPHONE {),t./-6-59?
STATE UC. #"18 Z66.3JCENSE CLASS /3-I CITY BUSINESS !JC. #
CITY STATE ZIP CODE DAY TELEPHONE STATE UC.#
7. WUltkEkS' WMPENSAIWN
workers· compensation uec1arat10n: I hereby afitrm that I have a certificate of consent toseif-msure issued 6y the b1rectorof Industrial
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 38001 Lab. C).
INSURANCE COMPANY POLICY NO. EXPIRATION DATE
Ceruhcate of Exemption: I certify that m the performance of the work for which this permit 1s issued, I shall not employ any person m any manner
so as to become 1ect to the Workers' Compensati~o/Laws of California.
DATE / / '-f
ere ya
• I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale.).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects
with contractor(s) licensed pursuant to the Contractor's License Law}.
• I am exempt under Section ________ Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's Llcense Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$500]),
SIGNATURE DATI!
coMJSlEJE IRIS Sl!CIION FOR NON-RESIDEN IIAL BUILDING PERMll's ONLV:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? • YES • NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? •YES •NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? •YES •NO
IF ANY OF THE ANSWERS ARI! YES, A FINAL CERTIFICATE OFoa;upANCY MAYNOf BEISSUl!DAFfER JULY I, 1989 UNLllSS THEAPPUCANT
HAS MET OR IS MEETING THE REQU!REMENTS OF nm OFFICE OF EMERGENCY SERVICES AND THE AIR POll.UTION CONTROL DISTIUCT.
9. WNSIROCIIDN IJ!NDING AGRNCf
I hereby athrm that there is a constructmn iendmg agency for the performance of the work for which this permit 1s issued (Sec 3097(1) C1vlI Code).
LENDER'S NAME LENDER'S ADDRESS
IO. XPPUCAN I cmtliFICAiiUN
I certify that I have read the apphcatton and state that the aOOve mformat1on 1s correct. I agree to comply with a)] Llfy ordmances and State laws
relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I AISO AGREE TO SAVE INDEMNIFY AND KEEP IIARM1JlSS THE CITY OF CARISBAD AGAINST AIL LIABILITIES, JUDGMENTS, CDSTS
AND EXPENSES WIDCH MAY IN ANY WAY Aa:RUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF TII1S PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by
such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code).
APPLICANTS SIGNATURE ~~c ,k r WHITE: pf;' YELLOW: Applicant PINK: Finance
DATE: ______ _
PERMIT# CB940271
DESCRIPTION: 225 SF ADDITION
FAMILY ROOM
TYPE: RAD
JOB ADDRESS:
CITY OF CARLSBAD
INSPECTION REQUEST
FOR 06/06/94
ONE STORY
STE:
INSPECTOR AREA PD
PLANCK# CB940271
OCC GRP R-3
CONSTR. TYPE VN
LOT:
APPLICANT:
CONTRACTOR:
151 HEMLOCK AV
CARPENTER, KENDALL PHONE: 619 941-6597
PHONE:
PHONE: /) L ~. ;JIJ OWNER:
REMARKS: BJN/KENDALL/941-6597 INSPECTO~~
SPECIAL INSTRUCT: WANTS INSPECTION AS EARLY AS POSSIBLE
TOTAL TIME:
--RELATED PERMITS--PERMIT# TYPE
SE890102 SWRSD
STATUS
ISSUED
CD LVL DESCRIPTION ACT COMMENTS
19 ST Final Structural
29 PL Final Plumbing
39 EL Final Electrical
49 ME Final Mechanical
------------------------------------
***** INSPECTION HISTORY*****
DATE DESCRIPTION ACT INSP COMMENTS
052394 Interior Lath/Drywall AP PD
051894 Insulation AP PD
051794 Rough Combo AP PD TEMP GLASS
042094 Roof/Reroof AP PD
BY DOOR
040694 Ftg/Foundation/Piers AP PD 20' SETBACK TO P/L
040594 Ftg/Foundation/Piers co PD
.JURISDICII<II: ClJ'J -r.AWSMP
to: __________________ _
EIICLOSUIIIS:, _______________ _
FLIXll Alll!A:_L=-::S:..:,'S"::........,pfc__ _____ _
SlllllIIS: __ ___:/ ________ _
IIEIGBr: ________________ _
RIIWIIS: _1...f,:....:.'l'r...:...(1')...:...t....:,l,1-Y___cR.:!:oo=""..;::_----
PI.All •iWMt I 1<11 PDT
CIT! Cl' C>P'PtP
~IPil PM'IIJ AID QUPLII !NPIDP
Date plans received by jurisdiction:
Da)e initial plan chack completed: >t-J"' By:...L..M..!...:.,;; c..:;;.~..;...;. ... _f....;..l _ _..p_q_ . ..;..i_t_,,._~_,)
Applicant contact person:
k~/JQ<il I r,.,,.,"./:tr-Ielephone: °fl.( I· G~ I I
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department.. You may have other corrections based
on laws and ordinances by the Planning Department,
Engineering Department or other departments.
Present california law mandates that residential
construction comply with Title 24 and the following
model codes:
1991 UBC (eff. 8/14/92)
1991 UPC (eff. 8/14/92)
1990 NEC (eff. 7/l/91)
1991 UMC (eff. 8/14/92)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
The circled items listed need clarification,
modification or change. All items have to be
satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec.
303(c), 1991 Uniform Building Code, the approval of
the plans does not permit the violation of any
state, cowity or city law.
To speed up tht recheck process, note on this list
( or a copy) wh•r• each correction item has been
addressed 1.,., plan sheet, specification, etc. Be
sure to enclose the marked up list when yoµ submit
the revised Plans,
IIDIII: PMZ MMlilllS AD 1'IJ? D Sll,.-O&ll:& AS PJIGIIS BAYIIIG NO 1DNS IIIDJ:m IIU@:t\...S 111111' DIJJCTID,
List Ko. 2, C&rlsbad Single Family Dwelling and Duplex With All Supplements. (1991 UBC)
1. Please make all ccrrections on the original
tracings and submit two new sets of prints, to:
2. Please make all corrections on the original
tracings and submit ·two new sets of prints, to:
3.
4,
5.
6.
8.
9.
The jurisdiction1 s building department.
Indicate on the Title Sheet of the plans, the
name of the legal oi,,mer and name of person
responsible for the preparation of the plans.
Section 302(a)7.
All sheets of plans must be signed by the
person responsible for their preparation.
(California Business and Professions Code).
Plans, specifications and calculations shall be
signed by the California state licensed
engineer or architect responsible for their
preparation, for plans deviating from
conventional wood frame construction. Specify
expirati lM date of license. (California
Business and Professions Code).
Specify on the Title Sheet of the plans the
gross floor area of each element of this
project including d,,.•elling, garage, carport,
patio, deck and balcony, Section 302(d).
Provide a statement on the Title Sheet of the
plans that this project shall comply with Title 24 and l99l UBC, UMC and UPC and 1990 NEC.
Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures 011. the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes. Show finish floor elevations and
show elevations of adjacent finish grade.
Show drainage patterns with minimum slopes.
Section 302(d).
Indicate distance from property lines to
proposed construction. Section 302(d).
10. Show on the title sheet all structures, pools,
walls, etc. included under this application.
Any portion of the project shown on the site
plan that is not included ~ith the building
permit application filed should be clearly
identified as "not include~."
11, Clearly show if the lower level is a basecent
or a story, based on the definitions in
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension
the distance to the floor above, for story
determination.
12. On the cover sheet of the plans, specify any
items requiring special inspection, in a
format similar to that sho,,.n below or sticky
back,
REQUIRED SPECIAL INSPECTIONS
In addition to the regular inspections, the
following checked items will also require
Special Inspection in accordance with Sec. 306
of the Uniform Building Code.
ITEM
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP,
STRUCTURAL CONCRETE OVER 2500 PSI
PRESTRESSED STEEL
Flll.D WELDING
HIGH STRENGTH BOLTS
EXPANSION ANCHORS
SPECIAL MASONRY
SPRAYED ON FIRE
PROOFING
PILES/CAISSONS
DESIGNER-SPECIFIED
OD!ER
REQ, IF
CHECKED
ffllE ntQl@!i\uN
REMARKS
13. Exterior walls closer than 3 feet to property
lines shall be one•hour rated construction and
have no openings. Table 5-A,
8/5 92 2
15.
16.
17,
18.
19,
Exterior walls closer than 3 feet to a
property line shall have JO inch parapets when
the floor area per floor exceeds 1,000 square
feet. See Section 1710 for possible exception.
Projections, including eaves, may not extend
more than 12 inches into the 3 foot setback
from the property line. Section 504(b).
Eaves over required windows shall be not less
than 30 inches from the side and rear property
lines. Section 504(a).
Projections, including eaves, shall be one-hour
fire-resistive construction, heavy timber or of
noncombustible material if they project into
the 3 1 setback area from the property line.
Section 1711.
Plastic skylights shall not be installed within
that portion of a roof located within a
distance to property line where openings in
exterior walls are prohibited or required to be
protected. Section 5207 (a) 7.
Show locations of permanently wired smoke
detector with battery backup:
a. Inside each bedroom.
b. Centrally located in corridor or area
giving access to sleeping rooms.
c. On each story.
d. In the basement, if part of the dwelling
unit.
e. When sleeping rooms are upstairs, at the
upper level in close proximity to the
stair.
f. In rooms adjacent to hallways serving
bedrooms, when such rooms have a ceiling
height 24 inches or more above the
ceiling height in the hallway.
NOTE: Detectors shall sound an alarm audible
in ill sleeping areas of the unit. Section
1210.
When the valuation of a room addition or
repair exceeds $1,000, er when sleeping rooms
are created, smoke detectors shall be provided
at existing bedrooms per item 19 above.
Section 1210.
21. Habitable rooms, other than kitchens, shall
contain at least 70 square feet of floor area..
At least one room shall have not less than 120
square feet of floor area. Section 1207 (b),
22. No habitable room, other than a kitchen, shall
be less than 7'011 in any dimension. Section
1207 (c).
5/22 92
23.
24.
27.
28.
29,
JO.
Sleeping rooms shall have a window or exterior
door for emerfency exit. Sill height shall
not exceed 44' above the floor. The window
must have an open.able area of at least 5. 7
square feet with the minimum openable width
20" and the minimum openable height 2411 •
Section 1204.
Basements in dwelling units shall comly with
the above (even if not designated as sleeping
rooms). Section 1204.
Window area must be at least 1/10 of the floor
area and a minimum of 10 square feet per
Section_l205 (b), Appears to be deficient in
Openable window area in habitable rooms must
be 1/20 of the floor area and a mini.mum of 5
square feet. In bathroocs, laundry rooms and
similar rooms 1/20 of area is required and
minimum is l.5 sq. ft. Section 1205 (c).
At least 1/2 of the comon wall must be open
and have an opening not less than 25 sq, ft.
nor one tenth of the floor area of the
interior room if light and ventilation is
being supplied from an adjacent room.
Section 1205 (a),
Required windows shall not open into a roofed
porch unless the ceiling height is at least 7
feet, the longer side is at least 65% open,
and the porch abuts a street, yard or court.
Section 1205 (a).
Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laWldry
rooms and similar rooms if required openable
windows are not provided. Section 1205 (c).
Note that the discharge point for exhaust air
will be at least 3 feet from any opening into
the building. Section l205(c).
31. Ductless fans cannot be used in bathrooms if a
tub or shower is present. Section 1205(c).
32. Show that ceilins height for habitable rooms
is a minimum of 716". Section 1207 (a).
JJ. Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a
minimum of 7 1 011• Section 1207 (a).
34. Dimension on the plans 3011 clear width for
"''ater closet compartments and 2411 clearance in
front of water closet. Section 511 (a).
J
72. Garages are not permitted to open into a room
used for sleeping purposes. Section 1104.
73. An occupancy separation is not required bet-.·een
carport and residence, provided the carport is
open on two or more sides and has no enclosed
uses above. Section 503 (a) Exception 3.
7•. Show garage framing sections, size of header
over garage opening, lateral cross bracing at
plate line, ciethod bracing garage front and
holddo.,..ns if required .. Chapter 23.
NOTE: "1aximum shear panel height-to-i,ddth
ratio is 3 1/2 to 1 for plywood. !able 25-I.
75. Doors may open into the garage only if the
floor or landing in the garage is not more than
one inch lower than the door threshold.
Section 3304 (i).
76. Provide an 1811 raised platform for any FAU,
v,ater heater, or other device in the garage
which may generate a flame or spark. UMC
Section 508, UPC Section 1310 (a).
Ji'OOMDA?'IOII g,.;ggl.REHEN1'S
77. Per soils report, note on the plan the soils
classification, whether or not the soil is
expansive and the allo..,,·able bearing value.
Section 2905 (c).
78. The foundation plan does not comply with the
soils report recommendations for this project.
Please review the report and modify design,
notes and details as required to show
79.
so.
compliance: ________________ _
Provide notes on the foundation plan listing
the soils report recommendation for
foundations, slab and building pad preparation.
The soils engineer recomended that he/she
review the foundation excavations. Note on
the foundation p Jan that "Prior to the
contractor requesting a Building Department
foundation inspection, the soils engineer
shall advise the building official in writing that: .
1. The building pad was prepared in
accordance with the soils report,
2. The utility trenches have been properly
backfilled and compacted, and
3. The foundation excavations comply 'od th
the intent of the soils report".
5/22/92
81. Provide a letter from the soils engineer
confirming that the foundation pla.n, grading
plan and specifications ha,·e been reviewed and
that it has been determined that' the
recommendations in the soils report are
properly incorporated into the construction
documents {when required by the soil report).
82.
83.
Show height of all foundation walls.
23.
Show height of
foundation walls.
retained earth
Chapter 23.
Chapter
on al 1
84. If cut or fill slopes exist, show distance
from foundation to. edge of cut or fill slopes
and show steepness and heights of cuts and
fills.
Chapter 29.
85. Note on plans that wood shall be 611 mini..ImJm
above finish grade. Section 2907 (a).
86. Note on plans that surface water will drain
away from building and show drainage pattern
and key elevations. Section 2905 (f).
87. Dimension foundation per U.B.C. !able 29A:
lli2.ll Footing
Su12~orted* Stemwall Width Depth Thickness
l 6" 1211 1211 6"
2 B" 15" 1811 7"
3 1011 1811 2411 B"
~':Foundations may support a roof in addition to the
floors. Where only a roof is supported, use
foundation for one floor.
88.
89.
90.
91.
Show foundation sills to be pressure treated,
or equal. Section 2516 (c) 3.
Show foW"ldation bolt size and spacing.
Section 2907 (f).
Specify size, I.C.B.O. number and manufacturer
of power driven pins and expansion anchors.
Show edge, end distances and spacing.
Section 302 (d).
If required, show size, embedment and location
of hold down anchors on foundation plan.
Section 302 (d).
If hold dews are required, note on plan that
hold down anchors must be tied in place ,prior
to foundation inspection. Section 305 {e) 1.
93. Show adequate footings under all bearing walls
and shear walls. Section 2907 (b).
6
115. Specify nail size and spacing for all shear
walls, floor and roof diaphragms. Indicate
required blocking. Maintain lllllJli.,,_.. diaphragm
dimension ratios. [Tables 25 I, J, K and
Section 4714 (d)].
116. Provide truss details and truss calculations
for this project. Specify truss identification
numbers on the plans.
117. Show 1/211 mini.cum clearance between top plate
of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
118. Provide roof £racing plan and floor framing
plan. Section 302 (d).
119. Provide framing sections through
Section 302 (d).
120. Specify all he.ader sizes for opening over 41
wide. Section 2517 (g) 5.
121. Provide calculations for main vertical and
horizontal framing members and post footings.
Section 302 (b).
122. Provide calculations for lateral loads, shear
panels, shear transfer and related. Section
302 (b).
123. In Seismic Zones 3 and 4, the allowable shear
,·all values for dry,.all in Table 47-1 must be
reduced SO percent when considering earthquake
loads. This does not apply to \/ind loads.
Footnote 1.
124. Show on the plans all structural requirements
developed in the structural calculations.
Section 302 ( d). (Sea cements below or at
end.)
125. Columns and posts located on concrete or
masonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be
supported by concrete piers or metal pedestals
projecting above floors unless approved wood
of natural resistance to decay or treated wood
is used. Section 2516 (c) 4.
126. Individual concrete or masonry piers shall
project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood is used. Section 2516 (c) 4.
127. Show location of attic access with a mini.mum
size of 22"x3011, unless the maximum vertical
headroom height in the attic is less than 30".
Access must be provided to each separated
attic area, shall be located in a hal!s·ay or
other readily accessible location and 3011
headroom clearance is required above the
opening. Section 3205(a).
128. Show location of attic acc·ess ..,ith minir.?WD
size 2211 x 3011 • Section 3205.
129. Detail truss layout for 3011 x 30" attic
access, if required for equipment in the
attic, and detail 3011 x 3011 clearance through
truss webs.
130. Specify plywood and/or particle board
thickness, grade and panel span rating.
Table 25-S.
131. Show plywood sheathing over exposed eaves, or
other weather exposed areas, is "bonded with
exterior glue.11 Plywood used for exterior
wal 1 covering shall be the exterior type.
Section 2516 (i), 2516(g)3.
132. When roof pitch is less than 3:12, design
ridge as a beam. Section 2517 (h).
133. Ridges, hips, and valleys shall be at least
one size larger than supported rafters.
Section 2517 (h) 3.
134. In open beam construction, provide strap ties
across the beams at the ridge support.
Section 2501 {b).
135. If foundation cripple ,·all studs are less
than 1411 high, framing shall be solid
blockins, or sheathed with ply...ood. Section
2517 (g) "·
136.
e
Cripple wall studs exceeding 4 feet in height
shall be 3 inch by 4 inch or 2 inches by 6
inches when supporting 2 stories.
Section 2517 (g) 4.
Neta on the plans that "all weather-exposed
surfaces shall have a weather-resistive
barrier to protect the int_erior wall covering
and that exterior openings shall be flashed in
such a manner as to make them weatherproof".
Section 1708.
l!BWIIICAJ. CUNP!/t!!! HllgWIICAL mm:)
All heating, ventilating, and cooling systems and
appliances shall comply with the Unifona Mechanical
Code.
5/22/92 8
185. Show on the Title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 112383. ~ All new residential buildings, including l7 additions, require a soils report. Please
submit t'w'o copies.. Exception: If a room
addition is limited to one story and 1000 sq,
ft. in area, then a soils report is not
required. Esgil Corporation will advise the
City to place their soils notice stamp on the
plans.
187. Heavy timber framing, minimum 611 x 1011 beams
and minimum 8" x 811 post, for the structural
beam and column supporting the fire separation
between the garage and living area above, is
acceptable if shown on the plans. (city
policy).
If you have any questions regarding these plan check items, please contact _______ _
If you have any questions
regarding City Building permit procedures, please
contact Carter Darnell at the City of Carlsbad,
2075 Las Palmas Dr., telephone 619/438-1161.
Thank you.
Enclosures:
188. All structures require a Class B roof covering, ~l~---------------------except room additions. If a room addition
covers all of the existing building (2nd story
addition), then the above exception doesn't ,,_2~-----------'------------apply.
189. City Ordinance 9792
spaces/unit with clear
washing machines, etc.
requires two ~arking
area of 20 1 x20' i.e. no
Show compliance.
190. Only tank-type water closets that use an
average of l. 6 gallons of water per flush or
less, and urinals and associated flushometer
valves, that use an average of 1 gallon of
water per flush or less shall be installed in
new construction. These provisions shall
apply to existing buildings only when toilets
are being replaced in existing bathrooms or
installed in new bathrooms.
l!TSCD VJIIIDOS
191. Please see additional corrections, or remarks,
on the following page.
192. To speed up the recheck process, note on this
list ( or a copy) where each correction item
has been addressed, i.e., plan sheet, note or
detail number, calculation page, etc.
193. Please indicate here if any changes have been
made to the plans that are not a result of
corrections from this list. If there are
other changes, please briefly describe them
and where they are located in the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
____ Yes ____ No
(. ,'+ /..
I k
8/11 92
3.
I
()V
13
City of Carlsbad
• ¥i ,f· ii ,t44ii ,g. I •14 ·SI ii; ,t4 Iii
3 I . £-ff.BUILDING PLANCHECK CHECKLIST /' /J. v,d '7 7/
DATE: U~ 'C_ PLANCHECK NO.l,/.,;., LL ... CJ(.., _
7 /
BUILDING ADDRESS: /57 .~kd...
PROJECT DESCRIPTION: /4. ~ al-: ,a/i
ASSESSOR's PARCEL NUMBER: cJ-a i-J-~2, -r f' EST. VALUE ~ ::z, ( f S--
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items
after this date, including field modifications, must
be reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to
comply with instructions in this report can result in
suspension of permit to build.
1st CHECK By: _______ _ Date:
2nd CHECK By:. _______ _ Date:
3rd CHECK By:. _______ _
ATTACHMENTS
D Dedication Application
D Dedication Checklist
D Improvement Application
D Improvement Checklist
Date:
DENIAL
Please see the attached report of deficiencies
marked with D Make necessary corrections to
plans or specifications for compliance with
applicable codes and standards. Submit corrected
plans and/or specifications to this office for review.
By: _________ Date: ___ _
By: _________ Date: ___ _
_________ Date: ___ _ By:
CONTACT PERSON
NAME: ______________ _
D Future Improvement Agreement
D Grading Permit Application ADDRESS:, ______________ _
D Right of Way Permit Application
D Sewer Fee Information Sheet PHONE: ______________ _
A-4
P:\DOCS\CHKLST\BP0001.FRM REV 12/17 /93
2075 Las Palmas Dr.• Carlsbad, CA 92009-1576 • (619) 438-1161 • FAX (619) 438-0894
BUILDING PLANCHECK CHECKLIST
~ 3rd✓
~~d-' 0
SITE PLAN
1. Provide a fully gimensioned site plan drawn to scale. Show:
A. North Arrow D. Property Lines Easements
B. Existing & Proposed Structures E. Easements
C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets
2. Show on site plan:
A. Drainage Patterns C. Existing Topography
B. Existing & Proposed Slopes
D D 3. Show on a section drawing or include a note stating that there Is a minimum of 6"
difference between the finished floor and the finished grade elevation adjacent to the
structure.
D D 4. Include note: "Surface water to be directed away from the building foundation at a 2%
gradient for no less than 5' or 2/3 the distance to the property line {whichever Is less).•
[Per 1985 UBC 2907(d)5].
•
On graded sites, the top of any exterior foundation shall extend above the elevation
of the street gutter at point of discharge or the inlet of an approved drainage device
a minimum of 12 inches plus two percent'' {per 1990 UBC 2907{d)5.).
5. Include on title sheet
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include: Total
building square footage with the square footage for each different use, existing sewer
permits showing square footage of different uses {manufacturing, warehouse, office,
etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
P:\DOCS\CHKLSnBP0001.FRM Page 1 of 4 REV 12/17/93
✓ 3rd✓
BUILDING PLANCHECK CHECKLIST
DISCRETIONARY APPROVAL COMPLIANCE
0 6. Project does not comply with the following Engineering Conditions of approval for
Project No. ________________________ _
Conditions were complied with by.: ______ _ Date:. _______ _
DEDICATION REQUIREMENTS
7. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and for
remodels with a value at or exceeding $. ______ -pursuant to Code Section
18.40.030.
Dedication required as follows: _________________ _
Attached please find an application form and submittal checklist for the dedication
process. Provide the completed application form and the requirements on the
checklist at the time of resubmittal.
Dedication completed by ____________ _ Date:. ____ _
IMPROVEMENT REQUIREMENTS
D D O Sa. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the construction
exceeds ""----------pursuant to Code Section 18.40.040.
Public improvements required as follows: ------'-----------
Please have a registered Civil Engineer prepare appropriate improvement plans and
submit them together with the requirements on the attached checklist for a separate
plancheck process through the Engineering Department. Improvement plans must be
approved, appropriate securities posted and fees paid prior to issuance of permit.
Attached please find an application form and submittal checklist for the public
Improvements requirements. Provide the completed application form and the
requirements on the checklist at the time of resubmittal.
Improvement Plans signed by: __________ _ Date: ___ _
P:\DOCS\CHKLS1\BP0001,FRM Page 2 014 REV 12/17/93
1st✓ 2nd✓ 3rd✓ • • •
BUILDING PLANCHECK CHECKLIST
Sb. Construction of the public improvements may be deferred pursuant to code Section
18.40. Please submit a recent property title report or current grant deed on the
property and processing fee of $. _________ so we may prepare the
necessary Future Improvement Agreement. This agreement must be signed, notarized
and approved by the City prior to issuance of a Building Permit.
Future public improvements required as follows: ___________ _
Improvement Plans signed by: ___________ _ Date: ____ _
D D D Sc. Enclosed please find your Future Improvement Agreement. Please return signed and
notarized Agreement to the Engineering Department.
• •
• •
•
•
•
•
Future Improvement Agreement completed by: ____________ _
Date: _______ _
Sd. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction of
the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section 11.06.030
of the Municipal Code.
9a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
9b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be Submitted together with the completed application form attached.
NOTE: The Grading Permit must be issued and rough grading approval obtained prior
to issuance of a Building Permit.
Grading Inspector sign off by: Date:
9c. No Grading Permit required.
BUILDING PLANCHECK CHECKLIST
P:\DOCS\CHKLSl\BP0001,FRM Page 3 of 4 REV 12/17/93
✓ 2nd✓ 3rd✓ • • f
MISCELLANEOUS PERMITS
10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are not
limited to: street improvements, trees, driveways.
A separate Right-of-Way permit issued by the Engineering Department is required for
the following: ______________________ _
Please complete attached Right-of-Way application form and return to the Engineering
Department together with the requirements on the attached Right-of-Way checklist, at
the time of resubmittal.
11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee
is noted in the fees section on the following page.
12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial
Waste Permit Application Form and submit for City approval prior to issuance of a
Permit.
Industrial waste permit accepted by: ______ _ Date: ___ _
P:\DOCS\CHKLST\BP0001.FRM Page 4 of 4 REV 12/17/13
·------
PLANNING OfECKUSf
Plan Check No. tj'LJ -27/ Address IS/ Hl'M}od< --'---------------Planner DAVID RICK
(Name)
Phone 438-1161 ext. _4_3_2_8 ___ _
APN: __ ___;,)..:.;O_,L/_-a:;J.:c.:.~_.2._ . ..:.;/8"'---------------
Type of Project and Use f\er q dJ ~ ~ >) s~ J .
Zone R -3/fJ.40 Facilities Management Zone __ _.,_ __
CPD (in(out) # cU"cle (,..,tf,...p_r_op_e_rty,.._IIl_,_c_o_m_p.-lete SPECIAL TAX CALCULATION
WORKSHEET provided by Building Department.)
Legend
[21 !tern Complete
(9 Item [ncomplete -Needs your action
1, 2, 3 Number in circle indicates plancheck number where deficiency was
identified
~ 0 0 Environmental Review Required: YES _ NO _L' 1YPE __ _
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval ______________________ _
c:f'• 0 Discretionary Action Required: YES _ NO ....,.L"TIPE __ _
APPROVAl/RESO. NO. ___ DATE: _____ _
PROJECT NO. ___ _
OTHER RELATED CASES: ___________________ _
Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ______________________ _
/ \9 0 0 California c.oastal Commission Permit Required: YES J NO _
DATE OF APPROVAL:
San Diego Coast Disnict, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725
(619) 521-8036
Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ______________________ _
c:{' 0 0 Inclusionary Housing Fee required: YES _ NO /
cf••
do •
i ••
C¥••
E:(o •
GI••
(Effective date of lnclusionary Housing Ordinance -May 21, 1993.)
· Site Plan:
Zoning:
1.
2.
1.
2.
3.
4.
Provide a fully dimensioned site plan drawn to scale. Show: North
arrow, property lines, easements, existing and proposed structures,
streets, existing street improvements, right-of-way width, dimensioned
setbacks and existing topographical lines.
Provide legal description of property, and assessor's parcel number.
Setbacks:
Front:
Int. Side:
Street Side:
Required ~O' Shown 2-'f 1
Required 51 Shown {z ;
Required tlft-Shown A/1:
Rear: Required lQI ' Shown ra''
Lot coverage: Required '=-IJ/,, Shown .... (tJj{,
Height: Required 30' Shown 12,' t, 11
Parking:
L? Q". UJ! 11,,,,. "1--f ~ I 1, ' -,,.,,o , . ....,_ .,,,1,v, 1 "" .
Spaces Required
Guest Spaces Required
0 0 D Additional Comments _______________________ _
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER ~~z____:: DATE _Lf+-,l~~/_i_LJ __
PLNCK.FRM
"TATE OF .CALIFORNIA-THE RESOURCES AGENCY
:AUFORNIA COASTAL COMMISSION
SAN 0IEGO COAST AREA
J 11 l CAMINO 0EL RIO NORTH, SUITE 200
':AN 0IEGO, CA 92108-172!i
:1191 521-8030
DATE:
NAME:
LOCATION:
PETE WILSON, Go""'rnor
EXEMPTION LETTER
This is to certify that this location and/or proposed project has been
reviewed by the staff of the Coastal Commission. A coastal development permit
is not necessary for the reasons checked below.
The site is not located within the coastal zone as established by the
California Coastal Act of 1976, as amended.
__ The proposed development is included in Categorical Exclusion No. ___ _
adopted by the California Coastal Commission.
__ The proposed development is judged to be repair or maintenance activity
not resulting in an addition to or enlargement or expansion of the object
Tsuch activities (Section 30610(d) of Coastal Act).
V The proposed development is an improvement to an existing single family
residence (Section 30610(c) of the Coastal Act) and not located in the
area between the sea and the first public road or within 300 feet of the
inland extent of any beach (whichever is greater) (Section 132SO(b)(4) of
14 Cal. Admin. Code.
__ The proposed development is an improvement to an existing single family
residence and is located in the area between the sea and the first public
road or within 300 feet of the inland extent of any beach (whichever is
greater) but is not a) an increase of 10% or more of internal floor area,
b) an increase in height over 10%, or c) a significant non-attached
structure (Sections 30610(a) of Coastal Act and Section 13250(b)(4) of
Administrative Regulations).
(OVER)
Page 2
The proposed development is an interior modification to an existing use
--with no change in the density or intensity of use (Section 30106 of
Coastal Act).
__ The proposed development involves the installation, testing and placement
in service of a necessary utility connecti-on between an existing service
facility and development approved in accordance with coastal development
permit requirements, pursuant to Coastal Act Section 30610(f).
The proposed development is an improvement to a structure other than a
single family residence or public works facility and is not subject to a
permit requirement (Section 13253 of Administrative Regulations).
__ The proposed development is the rebuilding of a structure, other than a
public works facility, destroyed by natural disaster. The replacement
conforms to all of the requirements of Coastal Act Section 30610(9).
Other:
Please be advised that only the project described above is exempt from the
permit requirements of the Coastal Act. Any change in the project may cause
it to lose its exempt status. This certification is based on information
provided by the recipient of this letter. If, at a later date, this
information is found to be incorrect or incomplete, this letter will become
invalid, and any development occurring at that time must cease until a coastal
development permit is obtained.
Truly yours,
By:
Title:
6630A