HomeMy WebLinkAbout151 HEMLOCK AVE; ; CB940271; PermitB U I L D I N G 04/01/94 10:17 1 Page 1 of 1 Job Address: 151 HEMLOCK AV Permit Type: RESIDENTAL ADD/ALT Parcel No: 204-252-18-00 Valuation: 22,695 Construction Type: VN P E R M I T Suite: Lot#: Permit No: CB940271 Project No: A9400391 Development No: Occupancy Group: R-3 Reference#: Status: ISSUED 03/15/94 04/01/94 MDP Description: 225 SF ADDITION ONE STORY : FAMILY ROOM Appl/Ownr : CARPENTER, KENDALL 5190 ALAMOSA PARK DRIVE OCEANSIDE , CA . 92057 *** Fees Required *** *** Fees: Adjustments: Total Fees: 408.00 .oo 408.00 Applied: Apr/Issue : 619 Entered By: 941-6597 Fees Collected & Credits Total Credits: Total Payments: Balance Due: .00 152.00 256.00 *** Fee description Units Fee/Unit Ext fee Data Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL Enter "Y" for Plumbinq Issue Fee > Enter 'Y f or Elec tric Issue Fee > Enter "Y" for Remodel > A ELELTF CAL TOTAL Enter 'Y' for Mechanical ~~ue fee> 234.00 152.00 2.00 388.00 10.00 10 .00 20.00 -//T:__APPRC I IN . ~-DATE: f t·<U( CLEA1,A vt ______ 1 CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 N y y N City of carlsbad Building Departaent 2075 Las Pal..,. Dr., Carlsbad, CA 92009 (619) 438·1161 I. PP1tMI I IYPE A -U Commercial U New Bmldmg Li I enant Improvement B -• Industrial LI New Building • Tenant Improvement ~ ~ C -• Residential • Apartment • Condo D Single Family Dwelling -:::,J.Addition/ Alteration • Duplex • Demolition • Relocation • Mobile Home • Electrical • Plumbing • Mechanical • Pool • Spa • Retaining Wall • Solar • Other PLAN CHECK NO. Zl{ 2. PROJF.Cr INFORMATION FOR: OFFICE USE ONLY Address /,5/ ./leJ-<L.oC-K. Nearest OW. Street Building or Suite No. LEGAL DEScRIM ION Lot No. Sulxi.lV1s1on Name/Number Omt No. Phase No. CHOCK BEWW If SUBMI 11 EU: • 2 Energy Cales • 2 Structural Cales • 2 Soils Report • 1 Addressed Envelope ASSESSOR'S PARCEL EXISTING USE PROPQSEP USE DESCRIPTION OF WORK SQ. FT. Z-s;-s-# OF STORIES ON~ 3. WN IACI PERSON (U Olflerent tram applicant) NAME ADDRESS CITY °t STATE ZIP CODE DAY TELEPHONE 4. XPPUCANI )ZFUNIRACIOR UACENI FUR WNIRAC10R uuwNntt NAME ?f~,1\/0_A-U.-~~DRESS s;"/9o ,,;k,~~ CITY O / Sf O , STATE /_,I/ ZIP CODE '9 3c:JS:-7DAY TELEPHONE CITY ~~.-$a.:'./ STATE CA• ZIP CODE DAY TELEPHONE CITY STATE ZIP CODE DAYTELEPHONE {),t./-6-59? STATE UC. #"18 Z66.3JCENSE CLASS /3-I CITY BUSINESS !JC. # CITY STATE ZIP CODE DAY TELEPHONE STATE UC.# 7. WUltkEkS' WMPENSAIWN workers· compensation uec1arat10n: I hereby afitrm that I have a certificate of consent toseif-msure issued 6y the b1rectorof Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 38001 Lab. C). INSURANCE COMPANY POLICY NO. EXPIRATION DATE Ceruhcate of Exemption: I certify that m the performance of the work for which this permit 1s issued, I shall not employ any person m any manner so as to become 1ect to the Workers' Compensati~o/Laws of California. DATE / / '-f ere ya • I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law}. • I am exempt under Section ________ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's Llcense Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]), SIGNATURE DATI! coMJSlEJE IRIS Sl!CIION FOR NON-RESIDEN IIAL BUILDING PERMll's ONLV: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? • YES • NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? •YES •NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? •YES •NO IF ANY OF THE ANSWERS ARI! YES, A FINAL CERTIFICATE OFoa;upANCY MAYNOf BEISSUl!DAFfER JULY I, 1989 UNLllSS THEAPPUCANT HAS MET OR IS MEETING THE REQU!REMENTS OF nm OFFICE OF EMERGENCY SERVICES AND THE AIR POll.UTION CONTROL DISTIUCT. 9. WNSIROCIIDN IJ!NDING AGRNCf I hereby athrm that there is a constructmn iendmg agency for the performance of the work for which this permit 1s issued (Sec 3097(1) C1vlI Code). LENDER'S NAME LENDER'S ADDRESS IO. XPPUCAN I cmtliFICAiiUN I certify that I have read the apphcatton and state that the aOOve mformat1on 1s correct. I agree to comply with a)] Llfy ordmances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I AISO AGREE TO SAVE INDEMNIFY AND KEEP IIARM1JlSS THE CITY OF CARISBAD AGAINST AIL LIABILITIES, JUDGMENTS, CDSTS AND EXPENSES WIDCH MAY IN ANY WAY Aa:RUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF TII1S PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPLICANTS SIGNATURE ~~c ,k r WHITE: pf;' YELLOW: Applicant PINK: Finance DATE: ______ _ PERMIT# CB940271 DESCRIPTION: 225 SF ADDITION FAMILY ROOM TYPE: RAD JOB ADDRESS: CITY OF CARLSBAD INSPECTION REQUEST FOR 06/06/94 ONE STORY STE: INSPECTOR AREA PD PLANCK# CB940271 OCC GRP R-3 CONSTR. TYPE VN LOT: APPLICANT: CONTRACTOR: 151 HEMLOCK AV CARPENTER, KENDALL PHONE: 619 941-6597 PHONE: PHONE: /) L ~. ;JIJ OWNER: REMARKS: BJN/KENDALL/941-6597 INSPECTO~~ SPECIAL INSTRUCT: WANTS INSPECTION AS EARLY AS POSSIBLE TOTAL TIME: --RELATED PERMITS--PERMIT# TYPE SE890102 SWRSD STATUS ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical ------------------------------------ ***** INSPECTION HISTORY***** DATE DESCRIPTION ACT INSP COMMENTS 052394 Interior Lath/Drywall AP PD 051894 Insulation AP PD 051794 Rough Combo AP PD TEMP GLASS 042094 Roof/Reroof AP PD BY DOOR 040694 Ftg/Foundation/Piers AP PD 20' SETBACK TO P/L 040594 Ftg/Foundation/Piers co PD .JURISDICII<II: ClJ'J -r.AWSMP to: __________________ _ EIICLOSUIIIS:, _______________ _ FLIXll Alll!A:_L=-::S:..:,'S"::........,pfc__ _____ _ SlllllIIS: __ ___:/ ________ _ IIEIGBr: ________________ _ RIIWIIS: _1...f,:....:.'l'r...:...(1')...:...t....:,l,1-Y___cR.:!:oo=""..;::_---- PI.All •iWMt I 1<11 PDT CIT! Cl' C>P'PtP ~IPil PM'IIJ AID QUPLII !NPIDP Date plans received by jurisdiction: Da)e initial plan chack completed: >t-J"' By:...L..M..!...:.,;; c..:;;.~..;...;. ... _f....;..l _ _..p_q_ . ..;..i_t_,,._~_,) Applicant contact person: k~/JQ<il I r,.,,.,"./:tr-Ielephone: °fl.( I· G~ I I Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department.. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present california law mandates that residential construction comply with Title 24 and the following model codes: 1991 UBC (eff. 8/14/92) 1991 UPC (eff. 8/14/92) 1990 NEC (eff. 7/l/91) 1991 UMC (eff. 8/14/92) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, cowity or city law. To speed up tht recheck process, note on this list ( or a copy) wh•r• each correction item has been addressed 1.,., plan sheet, specification, etc. Be sure to enclose the marked up list when yoµ submit the revised Plans, IIDIII: PMZ MMlilllS AD 1'IJ? D Sll,.-O&ll:& AS PJIGIIS BAYIIIG NO 1DNS IIIDJ:m IIU@:t\...S 111111' DIJJCTID, List Ko. 2, C&rlsbad Single Family Dwelling and Duplex With All Supplements. (1991 UBC) 1. Please make all ccrrections on the original tracings and submit two new sets of prints, to: 2. Please make all corrections on the original tracings and submit ·two new sets of prints, to: 3. 4, 5. 6. 8. 9. The jurisdiction1 s building department. Indicate on the Title Sheet of the plans, the name of the legal oi,,mer and name of person responsible for the preparation of the plans. Section 302(a)7. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Plans, specifications and calculations shall be signed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expirati lM date of license. (California Business and Professions Code). Specify on the Title Sheet of the plans the gross floor area of each element of this project including d,,.•elling, garage, carport, patio, deck and balcony, Section 302(d). Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and l99l UBC, UMC and UPC and 1990 NEC. Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures 011. the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes. Show finish floor elevations and show elevations of adjacent finish grade. Show drainage patterns with minimum slopes. Section 302(d). Indicate distance from property lines to proposed construction. Section 302(d). 10. Show on the title sheet all structures, pools, walls, etc. included under this application. Any portion of the project shown on the site plan that is not included ~ith the building permit application filed should be clearly identified as "not include~." 11, Clearly show if the lower level is a basecent or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. 12. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that sho,,.n below or sticky back, REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM SOILS COMPLIANCE PRIOR TO FOUNDATION INSP, STRUCTURAL CONCRETE OVER 2500 PSI PRESTRESSED STEEL Flll.D WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS SPECIAL MASONRY SPRAYED ON FIRE PROOFING PILES/CAISSONS DESIGNER-SPECIFIED OD!ER REQ, IF CHECKED ffllE ntQl@!i\uN REMARKS 13. Exterior walls closer than 3 feet to property lines shall be one•hour rated construction and have no openings. Table 5-A, 8/5 92 2 15. 16. 17, 18. 19, Exterior walls closer than 3 feet to a property line shall have JO inch parapets when the floor area per floor exceeds 1,000 square feet. See Section 1710 for possible exception. Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Section 504(b). Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 504(a). Projections, including eaves, shall be one-hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3 1 setback area from the property line. Section 1711. Plastic skylights shall not be installed within that portion of a roof located within a distance to property line where openings in exterior walls are prohibited or required to be protected. Section 5207 (a) 7. Show locations of permanently wired smoke detector with battery backup: a. Inside each bedroom. b. Centrally located in corridor or area giving access to sleeping rooms. c. On each story. d. In the basement, if part of the dwelling unit. e. When sleeping rooms are upstairs, at the upper level in close proximity to the stair. f. In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in ill sleeping areas of the unit. Section 1210. When the valuation of a room addition or repair exceeds $1,000, er when sleeping rooms are created, smoke detectors shall be provided at existing bedrooms per item 19 above. Section 1210. 21. Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area.. At least one room shall have not less than 120 square feet of floor area. Section 1207 (b), 22. No habitable room, other than a kitchen, shall be less than 7'011 in any dimension. Section 1207 (c). 5/22 92 23. 24. 27. 28. 29, JO. Sleeping rooms shall have a window or exterior door for emerfency exit. Sill height shall not exceed 44' above the floor. The window must have an open.able area of at least 5. 7 square feet with the minimum openable width 20" and the minimum openable height 2411 • Section 1204. Basements in dwelling units shall comly with the above (even if not designated as sleeping rooms). Section 1204. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section_l205 (b), Appears to be deficient in Openable window area in habitable rooms must be 1/20 of the floor area and a mini.mum of 5 square feet. In bathroocs, laundry rooms and similar rooms 1/20 of area is required and minimum is l.5 sq. ft. Section 1205 (c). At least 1/2 of the comon wall must be open and have an opening not less than 25 sq, ft. nor one tenth of the floor area of the interior room if light and ventilation is being supplied from an adjacent room. Section 1205 (a), Required windows shall not open into a roofed porch unless the ceiling height is at least 7 feet, the longer side is at least 65% open, and the porch abuts a street, yard or court. Section 1205 (a). Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, laWldry rooms and similar rooms if required openable windows are not provided. Section 1205 (c). Note that the discharge point for exhaust air will be at least 3 feet from any opening into the building. Section l205(c). 31. Ductless fans cannot be used in bathrooms if a tub or shower is present. Section 1205(c). 32. Show that ceilins height for habitable rooms is a minimum of 716". Section 1207 (a). JJ. Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7 1 011• Section 1207 (a). 34. Dimension on the plans 3011 clear width for "''ater closet compartments and 2411 clearance in front of water closet. Section 511 (a). J 72. Garages are not permitted to open into a room used for sleeping purposes. Section 1104. 73. An occupancy separation is not required bet-.·een carport and residence, provided the carport is open on two or more sides and has no enclosed uses above. Section 503 (a) Exception 3. 7•. Show garage framing sections, size of header over garage opening, lateral cross bracing at plate line, ciethod bracing garage front and holddo.,..ns if required .. Chapter 23. NOTE: "1aximum shear panel height-to-i,ddth ratio is 3 1/2 to 1 for plywood. !able 25-I. 75. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 3304 (i). 76. Provide an 1811 raised platform for any FAU, v,ater heater, or other device in the garage which may generate a flame or spark. UMC Section 508, UPC Section 1310 (a). Ji'OOMDA?'IOII g,.;ggl.REHEN1'S 77. Per soils report, note on the plan the soils classification, whether or not the soil is expansive and the allo..,,·able bearing value. Section 2905 (c). 78. The foundation plan does not comply with the soils report recommendations for this project. Please review the report and modify design, notes and details as required to show 79. so. compliance: ________________ _ Provide notes on the foundation plan listing the soils report recommendation for foundations, slab and building pad preparation. The soils engineer recomended that he/she review the foundation excavations. Note on the foundation p Jan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: . 1. The building pad was prepared in accordance with the soils report, 2. The utility trenches have been properly backfilled and compacted, and 3. The foundation excavations comply 'od th the intent of the soils report". 5/22/92 81. Provide a letter from the soils engineer confirming that the foundation pla.n, grading plan and specifications ha,·e been reviewed and that it has been determined that' the recommendations in the soils report are properly incorporated into the construction documents {when required by the soil report). 82. 83. Show height of all foundation walls. 23. Show height of foundation walls. retained earth Chapter 23. Chapter on al 1 84. If cut or fill slopes exist, show distance from foundation to. edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. 85. Note on plans that wood shall be 611 mini..ImJm above finish grade. Section 2907 (a). 86. Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Section 2905 (f). 87. Dimension foundation per U.B.C. !able 29A: lli2.ll Footing Su12~orted* Stemwall Width Depth Thickness l 6" 1211 1211 6" 2 B" 15" 1811 7" 3 1011 1811 2411 B" ~':Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. 88. 89. 90. 91. Show foundation sills to be pressure treated, or equal. Section 2516 (c) 3. Show foW"ldation bolt size and spacing. Section 2907 (f). Specify size, I.C.B.O. number and manufacturer of power driven pins and expansion anchors. Show edge, end distances and spacing. Section 302 (d). If required, show size, embedment and location of hold down anchors on foundation plan. Section 302 (d). If hold dews are required, note on plan that hold down anchors must be tied in place ,prior to foundation inspection. Section 305 {e) 1. 93. Show adequate footings under all bearing walls and shear walls. Section 2907 (b). 6 115. Specify nail size and spacing for all shear walls, floor and roof diaphragms. Indicate required blocking. Maintain lllllJli.,,_.. diaphragm dimension ratios. [Tables 25 I, J, K and Section 4714 (d)]. 116. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. 117. Show 1/211 mini.cum clearance between top plate of interior partitions and bottom chord of trusses. (To ensure loading will be as designed). 118. Provide roof £racing plan and floor framing plan. Section 302 (d). 119. Provide framing sections through Section 302 (d). 120. Specify all he.ader sizes for opening over 41 wide. Section 2517 (g) 5. 121. Provide calculations for main vertical and horizontal framing members and post footings. Section 302 (b). 122. Provide calculations for lateral loads, shear panels, shear transfer and related. Section 302 (b). 123. In Seismic Zones 3 and 4, the allowable shear ,·all values for dry,.all in Table 47-1 must be reduced SO percent when considering earthquake loads. This does not apply to \/ind loads. Footnote 1. 124. Show on the plans all structural requirements developed in the structural calculations. Section 302 ( d). (Sea cements below or at end.) 125. Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. 126. Individual concrete or masonry piers shall project at least 8 inches above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. 127. Show location of attic access with a mini.mum size of 22"x3011, unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hal!s·ay or other readily accessible location and 3011 headroom clearance is required above the opening. Section 3205(a). 128. Show location of attic acc·ess ..,ith minir.?WD size 2211 x 3011 • Section 3205. 129. Detail truss layout for 3011 x 30" attic access, if required for equipment in the attic, and detail 3011 x 3011 clearance through truss webs. 130. Specify plywood and/or particle board thickness, grade and panel span rating. Table 25-S. 131. Show plywood sheathing over exposed eaves, or other weather exposed areas, is "bonded with exterior glue.11 Plywood used for exterior wal 1 covering shall be the exterior type. Section 2516 (i), 2516(g)3. 132. When roof pitch is less than 3:12, design ridge as a beam. Section 2517 (h). 133. Ridges, hips, and valleys shall be at least one size larger than supported rafters. Section 2517 (h) 3. 134. In open beam construction, provide strap ties across the beams at the ridge support. Section 2501 {b). 135. If foundation cripple ,·all studs are less than 1411 high, framing shall be solid blockins, or sheathed with ply...ood. Section 2517 (g) "· 136. e Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. Neta on the plans that "all weather-exposed surfaces shall have a weather-resistive barrier to protect the int_erior wall covering and that exterior openings shall be flashed in such a manner as to make them weatherproof". Section 1708. l!BWIIICAJ. CUNP!/t!!! HllgWIICAL mm:) All heating, ventilating, and cooling systems and appliances shall comply with the Unifona Mechanical Code. 5/22/92 8 185. Show on the Title Sheet on the plans, the information required by the attached Developmental Services Sheet 112383. ~ All new residential buildings, including l7 additions, require a soils report. Please submit t'w'o copies.. Exception: If a room addition is limited to one story and 1000 sq, ft. in area, then a soils report is not required. Esgil Corporation will advise the City to place their soils notice stamp on the plans. 187. Heavy timber framing, minimum 611 x 1011 beams and minimum 8" x 811 post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). If you have any questions regarding these plan check items, please contact _______ _ If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 2075 Las Palmas Dr., telephone 619/438-1161. Thank you. Enclosures: 188. All structures require a Class B roof covering, ~l~---------------------except room additions. If a room addition covers all of the existing building (2nd story addition), then the above exception doesn't ,,_2~-----------'------------apply. 189. City Ordinance 9792 spaces/unit with clear washing machines, etc. requires two ~arking area of 20 1 x20' i.e. no Show compliance. 190. Only tank-type water closets that use an average of l. 6 gallons of water per flush or less, and urinals and associated flushometer valves, that use an average of 1 gallon of water per flush or less shall be installed in new construction. These provisions shall apply to existing buildings only when toilets are being replaced in existing bathrooms or installed in new bathrooms. l!TSCD VJIIIDOS 191. Please see additional corrections, or remarks, on the following page. 192. To speed up the recheck process, note on this list ( or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 193. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. ____ Yes ____ No (. ,'+ /.. I k 8/11 92 3. I ()V 13 City of Carlsbad • ¥i ,f· ii ,t44ii ,g. I •14 ·SI ii; ,t4 Iii 3 I . £-ff.BUILDING PLANCHECK CHECKLIST /' /J. v,d '7 7/ DATE: U~ 'C_ PLANCHECK NO.l,/.,;., LL ... CJ(.., _ 7 / BUILDING ADDRESS: /57 .~kd... PROJECT DESCRIPTION: /4. ~ al-: ,a/i ASSESSOR's PARCEL NUMBER: cJ-a i-J-~2, -r f' EST. VALUE ~ ::z, ( f S-- ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. 1st CHECK By: _______ _ Date: 2nd CHECK By:. _______ _ Date: 3rd CHECK By:. _______ _ ATTACHMENTS D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist Date: DENIAL Please see the attached report of deficiencies marked with D Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: _________ Date: ___ _ By: _________ Date: ___ _ _________ Date: ___ _ By: CONTACT PERSON NAME: ______________ _ D Future Improvement Agreement D Grading Permit Application ADDRESS:, ______________ _ D Right of Way Permit Application D Sewer Fee Information Sheet PHONE: ______________ _ A-4 P:\DOCS\CHKLST\BP0001.FRM REV 12/17 /93 2075 Las Palmas Dr.• Carlsbad, CA 92009-1576 • (619) 438-1161 • FAX (619) 438-0894 BUILDING PLANCHECK CHECKLIST ~ 3rd✓ ~~d-' 0 SITE PLAN 1. Provide a fully gimensioned site plan drawn to scale. Show: A. North Arrow D. Property Lines Easements B. Existing & Proposed Structures E. Easements C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets 2. Show on site plan: A. Drainage Patterns C. Existing Topography B. Existing & Proposed Slopes D D 3. Show on a section drawing or include a note stating that there Is a minimum of 6" difference between the finished floor and the finished grade elevation adjacent to the structure. D D 4. Include note: "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line {whichever Is less).• [Per 1985 UBC 2907(d)5]. • On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent'' {per 1990 UBC 2907{d)5.). 5. Include on title sheet A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses {manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION P:\DOCS\CHKLSnBP0001.FRM Page 1 of 4 REV 12/17/93 ✓ 3rd✓ BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE 0 6. Project does not comply with the following Engineering Conditions of approval for Project No. ________________________ _ Conditions were complied with by.: ______ _ Date:. _______ _ DEDICATION REQUIREMENTS 7. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $. ______ -pursuant to Code Section 18.40.030. Dedication required as follows: _________________ _ Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by ____________ _ Date:. ____ _ IMPROVEMENT REQUIREMENTS D D O Sa. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds ""----------pursuant to Code Section 18.40.040. Public improvements required as follows: ------'----------- Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public Improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Improvement Plans signed by: __________ _ Date: ___ _ P:\DOCS\CHKLS1\BP0001,FRM Page 2 014 REV 12/17/93 1st✓ 2nd✓ 3rd✓ • • • BUILDING PLANCHECK CHECKLIST Sb. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $. _________ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future public improvements required as follows: ___________ _ Improvement Plans signed by: ___________ _ Date: ____ _ D D D Sc. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department. • • • • • • • • Future Improvement Agreement completed by: ____________ _ Date: _______ _ Sd. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 9a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). 9b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: 9c. No Grading Permit required. BUILDING PLANCHECK CHECKLIST P:\DOCS\CHKLSl\BP0001,FRM Page 3 of 4 REV 12/17/93 ✓ 2nd✓ 3rd✓ • • f MISCELLANEOUS PERMITS 10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, trees, driveways. A separate Right-of-Way permit issued by the Engineering Department is required for the following: ______________________ _ Please complete attached Right-of-Way application form and return to the Engineering Department together with the requirements on the attached Right-of-Way checklist, at the time of resubmittal. 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial waste permit accepted by: ______ _ Date: ___ _ P:\DOCS\CHKLST\BP0001.FRM Page 4 of 4 REV 12/17/13 ·------ PLANNING OfECKUSf Plan Check No. tj'LJ -27/ Address IS/ Hl'M}od< --'---------------Planner DAVID RICK (Name) Phone 438-1161 ext. _4_3_2_8 ___ _ APN: __ ___;,)..:.;O_,L/_-a:;J.:c.:.~_.2._ . ..:.;/8"'--------------- Type of Project and Use f\er q dJ ~ ~ >) s~ J . Zone R -3/fJ.40 Facilities Management Zone __ _.,_ __ CPD (in(out) # cU"cle (,..,tf,...p_r_op_e_rty,.._IIl_,_c_o_m_p.-lete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department.) Legend [21 !tern Complete (9 Item [ncomplete -Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified ~ 0 0 Environmental Review Required: YES _ NO _L' 1YPE __ _ DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ______________________ _ c:f'• 0 Discretionary Action Required: YES _ NO ....,.L"TIPE __ _ APPROVAl/RESO. NO. ___ DATE: _____ _ PROJECT NO. ___ _ OTHER RELATED CASES: ___________________ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ______________________ _ / \9 0 0 California c.oastal Commission Permit Required: YES J NO _ DATE OF APPROVAL: San Diego Coast Disnict, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ______________________ _ c:{' 0 0 Inclusionary Housing Fee required: YES _ NO / cf•• do • i •• C¥•• E:(o • GI•• (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) · Site Plan: Zoning: 1. 2. 1. 2. 3. 4. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensioned setbacks and existing topographical lines. Provide legal description of property, and assessor's parcel number. Setbacks: Front: Int. Side: Street Side: Required ~O' Shown 2-'f 1 Required 51 Shown {z ; Required tlft-Shown A/1: Rear: Required lQI ' Shown ra'' Lot coverage: Required '=-IJ/,, Shown .... (tJj{, Height: Required 30' Shown 12,' t, 11 Parking: L? Q". UJ! 11,,,,. "1--f ~ I 1, ' -,,.,,o , . ....,_ .,,,1,v, 1 "" . Spaces Required Guest Spaces Required 0 0 D Additional Comments _______________________ _ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER ~~z____:: DATE _Lf+-,l~~/_i_LJ __ PLNCK.FRM "TATE OF .CALIFORNIA-THE RESOURCES AGENCY :AUFORNIA COASTAL COMMISSION SAN 0IEGO COAST AREA J 11 l CAMINO 0EL RIO NORTH, SUITE 200 ':AN 0IEGO, CA 92108-172!i :1191 521-8030 DATE: NAME: LOCATION: PETE WILSON, Go""'rnor EXEMPTION LETTER This is to certify that this location and/or proposed project has been reviewed by the staff of the Coastal Commission. A coastal development permit is not necessary for the reasons checked below. The site is not located within the coastal zone as established by the California Coastal Act of 1976, as amended. __ The proposed development is included in Categorical Exclusion No. ___ _ adopted by the California Coastal Commission. __ The proposed development is judged to be repair or maintenance activity not resulting in an addition to or enlargement or expansion of the object Tsuch activities (Section 30610(d) of Coastal Act). V The proposed development is an improvement to an existing single family residence (Section 30610(c) of the Coastal Act) and not located in the area between the sea and the first public road or within 300 feet of the inland extent of any beach (whichever is greater) (Section 132SO(b)(4) of 14 Cal. Admin. Code. __ The proposed development is an improvement to an existing single family residence and is located in the area between the sea and the first public road or within 300 feet of the inland extent of any beach (whichever is greater) but is not a) an increase of 10% or more of internal floor area, b) an increase in height over 10%, or c) a significant non-attached structure (Sections 30610(a) of Coastal Act and Section 13250(b)(4) of Administrative Regulations). (OVER) Page 2 The proposed development is an interior modification to an existing use --with no change in the density or intensity of use (Section 30106 of Coastal Act). __ The proposed development involves the installation, testing and placement in service of a necessary utility connecti-on between an existing service facility and development approved in accordance with coastal development permit requirements, pursuant to Coastal Act Section 30610(f). The proposed development is an improvement to a structure other than a single family residence or public works facility and is not subject to a permit requirement (Section 13253 of Administrative Regulations). __ The proposed development is the rebuilding of a structure, other than a public works facility, destroyed by natural disaster. The replacement conforms to all of the requirements of Coastal Act Section 30610(9). Other: Please be advised that only the project described above is exempt from the permit requirements of the Coastal Act. Any change in the project may cause it to lose its exempt status. This certification is based on information provided by the recipient of this letter. If, at a later date, this information is found to be incorrect or incomplete, this letter will become invalid, and any development occurring at that time must cease until a coastal development permit is obtained. Truly yours, By: Title: 6630A