Loading...
HomeMy WebLinkAbout1525 FARADAY AVE; 290; CB053861; PermitCity of Carlsbad 12-27-2005 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB053861 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: 1525 FARADAY AV CBAD Tl -Jr ;;..t/,t) Sub Type: Lot#: COMM 0 Status: Valuation: 2121302700 $228,725.00 Construction Type: 111 Applied: ISSUED 11/04/2005 LSM 12/27/2005 12/27/2005 Occupancy Group: Reference #: Entered By: Project Title: MALCOLM PIRNIE-2100 OFF TO OF 4,435 SHELL TO OFFICE Applicant: PACIFIC INTERIOR SYSTEMS 6364 FERRIS SQUARE SAN DIEGO, CA 92121 858-774-6726 Building Permit Add'I Building Permit Fee Plan Check Add'f Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD#2 Fee BTD#3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee $943.88 $0.00 $613.52 $0.00 $0.00 $48.03 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Plan Approved: Issued: Inspect Area: Plan Check#: Owner: NEWPORT NATIONAUCORNERSTONE LL C C/O SCOTT BRUSSEAU NEWPORT NATL 1525 FARADAY AVE #100 CARLSBAD CA 92008 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES Total Fees: $12,510.17 Total Payments To Date: $12,510.17 Balance Due: L Inspector: BUIWING PLANS ~IN STORAGE -ATTACHED Clearance: $0.00 $0.00 $0.00 $0.00 $2,825.10 $0.00 $0.00 $0.00 $1,876.00 $0.00 $34.00 $310.00 $80.00 $0.00 $5,779.64 $0.00 $0.00 $12,510.17 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions." You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. "" FOR OFFICE USE ONLY I PERMIT APPLICATION PLAN CHECK NO. <!.6 os?::.?S b/1 EST. VAL. ~ 'is 7 ~ CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 Plan Ck. Deposit ~ -6'.:;2. Validated By __ --=~'--------- Date I l / 4 / o..S-' . Address (include Bldg/Suite #) @h -~vAve-Business Name (at this address) ~te., .2!10 wv(~loa& , CA q.!leDB> k[a(cotm Legal Description f Lot No. Subdivision Name/Number Unit No. Total # of units ee,,,-re~ Assessor's Parcel # Existing Use f02.. Q:u-lstxu{ Resevek Proposed Use office< 212--t.30 ... ,2}7-e:o &,.-.;T™~ 4ell /o-fft-c.e.-s. # of Bedrooms # of Bathrooms Name Address City ~ -:''J(i>.Pl,l,CANT: jQ'contr~otor-'" l~g:ertdoi:J:bnt,ritbt9r, 'Crowner, · -~-g;rrtifor'ewner'. De~ tq11 c:o...-p Add~ess 444 s, u&vt>s. Av~ ·:.. -Ste ifl7B State/Zip (2A Telephone# . . 4.i.:o<t~ -----.. (EJ;S) o/tl4h3~~2 -~a_me_c.orm-~ ~tr:12-ID~C.-. -~d-~re~sP?~-~~()..y_A~·-_Cit:Ch~$_b~:-_7t~-~z:,;,~_ ,_ -~ti;;:)0"0v:.;;.,-4gg \5,: ;C9NL!\QT0fl'.-qQM~4fl!Y-,,AIVIJ: . , ., , , sa :(:{, (t,t:> ""1.-=-1:/o;> · ' · • · · · • .•. 2- (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). /11.?<~ &.-lo.'tnd chop 'G78± /tJ.eA"-ftc,, ler°ct£v: Blvol. ~"l D.i?W Ct\ q.2..\.2-f (8EB)f31jz,-06Do Name .;;:::J Address City '<lstate/Z1p Telephone # e;o2B'1b --~2ZZ State License # ~~0 (!. W9f!J!;,R$' C,QM,P~_!'J$ATIQN . . . . . Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ·g I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is /4sued. My worker's compensation insurance carrier and policy number are: • Insurance Company ST. @e1t \ fu t.. "10.. v-rne l 115. Policy No. kc Dh( {!)(;)04!{ Expiration Date ·3/ l / Ob (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars {$100,000}, in d 'tion to the cos of comp nsation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE :?'. r DATE // /4/--,/05 Z... '"PYVN.;..!'!~~V.!L,P,ER_ 0§.Gµ ATI_Q~. t._ -" '' • . ' , -· ... -~-.. _ ~ : • , -.:: ~ . •· I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted _with the following person (firm) to provide the proposed construction (include name / address / phone number/ contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number I contractors license number):. _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address / phone number/ type of work):. ________________________________________________________ _ PROPERTY OWNER SIGNATURE ______________________ _ DATE _________ _ :cQMP~M~.J'tiJs .l?~cri;:li;>r-tFQJi NQNilif$IPENr1AL.au11!,e1~q :fERMIT$: oN~Y . · Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ~~:~·_e,9_f'4~.TRYPr.19rfLJRi?T®.-A.9ENcY.: : .. ~ ·:-~.-.. --. .::.: .. :--• · · • : ..... · :~ ... ," .... , .. ~,' I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a p ri d of 180 days (Section 6.4.4 Uniform Building Code}. APPLICANT'S SIGNATURE ----,~-_,,:.~4,,/,~a--,,Y~~-;,q.,~"--~--------DATE -----l/'--'-l--+-/1::,.-f---+-,l.=.,o~"""'-5_ WHITE: File YELLOW: Applicant PINK: Finance CllV of Carlsbad · Flnal Bulldlna lnsnectlon Dept: Building Engineering Planning CMWD St Lite <Effiv Plan Check #: Permit#: Project Name: CB053861 MALCOLM PIRNIE-2100 OFF TO OF 4,435 SHELL TO OFFICE Address: 1525 FARADAY AV Contact Person: STEVEN Phone: 8589675918 Sewer Dist: CA Water Dist: CA D te: PJrmit Type: S lb Type: Lot: 0 01/26/2006 Tl COMM Inspected~ A ~ Date / / By: ~ ,kl-~ tfal~ Inspected: 11.-5-./tJ--(> Approve : ~approved: __ Inspected 1 / Date 1 1 By: · Inspected:-----Approve, : ___ Disapproved: __ Inspected Date J By: __________ Inspected: ______ Approveb: ___ Disapproved: __ ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• J •••••••••••••••••••••••••••••••••••••••••• ,.,11 Comments: City of Carlsbad Bldg Inspection Request For: 01/27/2006 Permit# CB053861 Title: MALCOLM PIRNIE-2100 OFF TO OF Description: 4,435 SHELL TO OFFICE Type: Tl Job Address: Sub Type: COMM 1525 FARADAY AV Suite: Lot 0 Location: APPLICANT PACIFIC INTERIOR SYSTEMS Owner: NEWPORT NATIONAL/CORNERSTONE LL C Remarks: EARLY AM PLEASE Total Time: CD Description Act Comment 19 Final Structural r:t5_ 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Comments/Notices/Hold Associated PCRs/CVs Original PC# Inspector Assignment: JM --- Phone: 8589675918 Inspector: ----- Requested By: STEVEN Entered By: CHRISTINE PCR02014 ISSUED PCR02080 ISSUED MERALD LAKE CORP CNTR-REVISE; ELEVATOR SUMP & MECH ENCLOSURE EMERALD LAKE CORP CENTER; CHANGE TO METAL STUDS PCR03036 ISSUED EMERALD LAKE CENTER-REVISE; INCREASE SPRINKLERS IN LIEU-PROTECT OPB Inspection History Date Description Act lnsp Comments 01/19/2006 14 Frame/Steel/Bolting/Welding AP JM CEILING 01/19/2006 34 Rough Electric AP JM 01/19/2006 39 Final Electrical AP JM EMR 01/18/2006 39 Final Electrical co JM 01/18/2006 84 Rough Combo co JM FIVE FIRST 12/30/2005 17 Interior Lath/Drywall AP JM 12/28/2005 14 Frame/Steel/Bolting/Welding AP JM WALLS 12/28/2005 21 Underground/Under Floor AP JM SINK 12/28/2005 22 Sewer/Water Service WC JM 12/28/2005 34 Rough Electric AP JM WALLS City of Carlsbad Bldg Inspection Request For: 01/19/2006 Permit# CB053861 Title: MALCOLM PIRNIE-2100 OFF TO OF Description: 4,435 SHELL TO OFFICE Type: Tl Job Address: Suite: Location: Sub Type: COMM 1525 FARADAY AV Lot 0 APPLICANT PACIFIC INTERIOR SYSTEMS Owner: NEWPORT NATIONAL/CORNERSTONE LL C Remarks: Total Time: CD Description 14 Frame/Steel/Bolting/Welding 39 Final E~ect~ical ,<;7 13!L_ ~'·ill., f.i..L=L_ Comments/Notices/Hold Associated PCRs/CVs Original PC# Inspector Assignment: JM --- Phone: 8589675918 Inspector: ----- Requested By: STEVEN Entered By: JANEAN PCR02014 ISSUED PCR02080 ISSUED MERALD LAKE CORP CNTR-REVISE; ELEV ATOR SUMP & MECH ENCLOSURE EMERALD LAKE CORP CENTER; CHANGE TO METAL STUDS PCR03036 ISSUED EMERALD LAKE CENTER-REVISE; INCREASE SPRINKLERS IN LIEU-PROTECT OPE!' Inspection History Date Description Act lnsp Comments 01/18/2006 39 Final Electrical co JM 01/18/2006 84 Rough Combo co JM FIVE FIRST 12/30/2005 17 Interior Lath/Drywall AP JM 12/28/2005 14 Frame/Steel/Bolting/Welding AP JM WALLS 12/28/2005 21 Underground/Under Floor AP JM SINK 12/28/2005 22 Sewer/Water Service WC JM 12/28/2005 34 Rough Electric AP JM WALLS EsGil Corporation In. Partn.ers/i.ip wit/i. (jove.rnmen.t for !Bui(ain.g Safety DATE: 12/21/05 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-3861 SET:111 PROJECT ADDRESS: 1525 Faraday Ave Suite 290 PROJECT NAME: Malcolm Pirnie ... TI D APPLICANT Ca Ju §Js::S" D PLAN REVIEWER D FILE ~ The plans transmitted herewith have been corrected whe're necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Mail Telephone Fax In Person D REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Telephone #: Fax#: Enclosures: 12/15/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 I -,_. "'-\ EsGil Corporation In <Partnersfzip witfz <}overnmentfor<Bui{aing Safety DATE: 12/14/05 D APPLICANT C tJ' JURIS :> JURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-3861 SET: II D PLAN REVIEWER D FILE PROJECT ADDRESS: 1525 Faraday Ave Suite 290 PROJECT NAME: Malcolm Pirnie -TI D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Design Corp. /Chie Honda 444 S. Cedros Ave Suite 175, Solana Beach, CA 92075 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: 9hie Honda Date contacted:/;;../ !f /o¢1y;//...$) Mail Telephone /' Fax ~n Person REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Telephone#: 858-794-3222 Fax #: 858-794-3220 Enclosures: 12/7/05 trnsmtLdot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 · City of Carlsbad 05-3861 12/14/05 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-3861 PROJECT ADDRESS: 1525 Faraday Ave Suite 290 SET: II DATE PLAN RECEIVED BY ESGIL CORPORATION: 12/7/05 REVIEWED BY: Doug Moody FOREWORD (PLEASE READ): DATE RECHECK COMPLETED: 12/14/05 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new complete sets of prints to: B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes ONo City of Carlsbad 05-3861 12/14/05 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 1. Please clarify the section view of the new 78" interior partition wall type 4. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of providing lateral bracing. (Please provide complete details of the tube steel and the connection to the floor and calculations to show the design to comply with section 1611.5). Please provide the listing and installation information for the new Tiger brand post or provide calculations to show the post adequate. 3. Please indicate in the door schedule the type of controlled access hardware and provide the listing information to show the hardware to be an approved component of the egress system. Please provide the listing and installation information for the controlled egress system. 4. Exit doors should swing in the direction of exit travel when the area served has an occupant load of 50 or more. Section 1003.3.1.5. The reception door #1 which is an egress door must comply. 7. Please revise the single line diagram to show the feeder to panel HA to be 3/0 cu and not 2/0. Table 310-16 of the NEC. The conductors have been corrected to the appropriate size but the conduit was not correct for the new conductor size. Please revise the plans to show a minimum of a 2". To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. '·' City of Carlsbad 05-3861 12/14/05 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In (!'artners~ip witli <]overnment for (]3ui{aing Safety DATE: 11/16/05 <:a APPLICANT •JUflS~ JURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-3861 SET:I D PLAN REVIEWER D FILE PROJECT ADDRESS: 1525 Faraday Ave Suite 290 PROJECT NAME: Malcolm Pirnie -TI D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held _at Esgil Corporation until corrected plans are submitted for recheck. · The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Design Corp. /Chie Honda 444 S. Cedros Ave Suite 175, Solana Beach, CA 92075 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Chie Honda Telephone#: 858-794-3222 Date contacted: 11 \l<D ( o;, (by:P'\' ) _ Fax #: 858-794-3220 Mail Telephone /Fax v'ln Person REMARKS: "'\'f" By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 11/7/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 5.60-1576 ' .l. City of Carlsbad 05-3861 11/16/05 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 05-3861 OCCUPANCY: B TYPE OF CONSTRUCTION: IllH ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 11/4/05 DATE INITIAL PLAN REVIEW COMPLETED: 11/16/05 FOREWORD .(PLEASE READ): JURISDICTION: City of Carlsbad USE: Office ACTUAL AREA: 65 l 4sf STORIES: 2 HEIGHT: OCCUPANT LOAD: 95 DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/7/05 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY ~::.JPPLEMENTS (1997UBC) tiforw.dot I ) / City of Carlsbad 05-3861 11/16/05 Please make all correcti<;ms on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected ~ets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the.plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Please clarify the section. view of the new 78" interior partition wall type 4. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of providing lateral bracing. (Please provide complete details of the tube steel and .the connection to the floor and calculations to show the design to comply with section 1611.5). 2. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 708. 3. Please indicate in the door schedule the type of controlled access hardware and provide the listing information to show the hardware to be an approved component of the egress system. 4. Exit doors should swing in the direction of exit travel when the area served has an occupant load of 50 or more. Section 1003.3.1.5. 5. When additional doors are provided for egress purposes, they shall conform to the width, swing and hardware provisions in Chapter 10. Section 1003.3.1.1. 6. Please note qn the plans "AC Cable is not allowed in A, B, E, H, and I occupancies.· NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment groun:! conductor is to be installed in all flexible conduits". 7. Please revise the single line diagram to show the feeder to panel HA to be 3/0 cu and not 2/0. Table 310-16 of the NEC. , ' ,r City of Carlsbad 05-3861 11/16/05 8. Please clarify the single line diagram to show the grounding location for the new transformer XA. 9. Provide correct the energy designs for the proposed changes in the mechanical system to show the server AC. Provide the corrected MECH-1-C forms showing energy compliance. 10. The completed and signed MECH-1-C forms must be imprinted on the plans. 11. Please have the principle designer check the appropriate box in the Statement of Compliance section of the MECH-1-C energy document and sign the appropriate portion. 12. Please have the principle designer check the appropriate box( s) in the Statement of Compliance System Acceptance section of the MECH-1 documents. 13. Please indicate the location of the mandatory measures imprinted on the plans. 14. Show that the minimum strike edge distances are provided at the level area on the side to which a door swings for door #4, per Section 1133B.2.4.3: a) ~18" at interior conditions. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. , City of Carlsbad 05-3861 11/16/05 I VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody PLAN CHECK NO.: 05-3861 DATE: 11/16/05 BUILDING ADDRESS: 1525 Faraday Ave Suite 290 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Tl 6514 City Valuation Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: 0 Complete Review D Structural Only D Repetitive Fee 3 Repeats Comments: D Other D Hourly I . · I Hour * Esgil Plan Review Fee ($) 228,725 228,725 $943.881 $613.521 $528.571 Sheet 1 of 1 macvalue.doc . ·r ·:1 ,. .. ' PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB Q \. / 3f 0 I / DATE ____ / ___ l (_z,f_a_I,_ ADDRESS ____ ;_s_~ ___ 2 __ r_/_;z:t:..__---~_~_~--i---------- J RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER ____________________ _ PLANNER {cC DATE ENGINEER DATE (I/ v1-/o 1 / ~ a)j_c;.,~ Docs/Misforms/Planning Engineering Approvals . ., . .;: , ... · ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D Estimate based on unconf med information from applicant. D Calculation based on bui cf g plancheck plan submittal. Date: Prepared by: Checked by: -------------- EDU CALCULATIONS: List types and square footages for all uses. Types of Use: aio·I Le. Sq. Ft./Units: (_{'{] (.--EDU's: __ (_, _i_0?_ Types of Use:·_______ Sq. Ft./Units:______ EDU's: ----~ r c..e. , 1. 1 ,,.. ADT CALCULATIONS: List tyP,es~d square footages for all uses. Types of Use: V ~/ 3 ~ q. Ft./Units: '7 '-f J J ADT's: -~0~] __ Types of Use: -------Sq. Ft./Units: ------ADT's: ------ FEES REQUIRED: WITHIN CFO: D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) o· NO D 1. PARK-IN-LIEU FEE PARK AREA & #: ___ _ FEE/UNIT: ____ _ X NO. UNITS:_. __ D 2. TRAFFIC IMPACT FEE 6 / ADT's/UNITS: ____ _ X~T: --zr D 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 DIST. #2 DIST. #3 __ ) ADT's/UNITS: ____ _ X FEE/ADT: ___ _ =$ ~- , D 4. FACILITIES MANAGEMENT FEE . ZONE: ___ _ D UNIT/SQ.FT.: ____ _ 5. SEWER FEE !.~~ EDU's: ____ _ BENEFIT AREA: _r-__ _ 7 EDU's: . /. ~ ~ 0 6. SEWER LATERAL ($2,500} D 7. DRAINAGE FEES PLDA. ___ _ ACRES: _____ _ D 8. POTABLE WATER FEES UNITS CODE CONNECTION FEE - X FEE/SQ.FT.I.UNIT: ___ _ X ,-- FEE/EDU: ')-f ~ =$_ )!:sic. 3 a X ~EDU: 1/4, / ") = $_~------------ HIGH ___ /LOW __ _ X ·FEE/AC: ___ _ =$ ~-.... METER FEE SDCWA FEE IRRIGATION 1 of2 .. ,, .. , "" .·· crv~1-.· .. · ·(.C)'k ~- . . I. -V c,, .. ·~.<.,t..,. Lf y ) J-/; s-!l'J . --' . , ~ .. P7 ~~ .w-· ,· ! ; .. \. I ~ N 'II: """ tl '-' Q) Q) .s:: .t:: u u C: C: "' "' a: ii: ~DD ~DD PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Os ~~tel Address_ ( 5?5' fvdti~/tvt *· .2-'] D Planner Greg Fisher Phone :(760) 602-4629 Cw l.~1o-;:J[ q 2-DD.:g APN: 2--1.2-l~0-1-]-oO Type of Project & Use: I, .:C... Net Project Density: DU/AC Zoning: G /V\ Gene~al Plan: P \ Faciliti~s Management Zone: _S __ _ CFO (in/out) # _Date of participation: ____ Remaining net dev acres: __ _ Circle One (For non-residential· development: Type of land used created by this permit: ___________________ ) Legend: [gl Item Complete Environmental Review Required: D Item Incomplete -Needs your action YES_ N~ TYPE ___ _ DATE OF COMPLETION: ________ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: Y~S _ N%-TYPE __ _ APPROVAL/RESO. NO. _______ DATE __ _ PROJECT NO. _________ _ OTHER RELATED CASES: ___________________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: ---------------------- Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES __ CA Coastal Commission Authority? YES__ NO If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. lnclusionary Housing Fee required: YES __ NO r (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data Entry Completed? YES __ NO __ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Ho\Jsing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/0-1 ., D 0 D ?zj)o D ,~D ~o:o ~o -Site Plan: i. Provide, a fully dimensional: site plan drawn to scale. Show: North arrow, property lines. easemerns, existing and ;p'roposed structures, streets, existing street improvements, riah1-· ·.ot~way width, dimemsion~I setpack~ and e.xisting topographical lines (including all side ~nq '.rear yard slc;>pes). · · · . · , 2. Provide Ie·g·aI ·desc:ription· Qf.prqpe,rty and assessor's parcel number.. Policy .44. -Neighborhood Architectural Desis,n Gµidelines 1 .. Applicability:: YES-'. '"",-,'---'-..... ·No_·_. -,---,--- 2. Prqject complies. YE$ . NO_· -,--- Zc;ming: 1 . Setbapks: Fron"t: Interior Side: Street Side: ,fiear,:. Top of slope: ; Required Shown -------,.,..,----------------'Required .... · ____ ....__ Shown ____ -"-'-__,,....:....,,.-- Requireq Shown --------------,,..--,----Required· · Shown ---------'----,--'---'-----,--,-·Reqpired _______ Shown --,....,-------- 2. Ac¢essory str.uc.ture·setbacks: Front: RequirE;?d' ------I n t er i or Side: Required -,-------Street Side; Required __ ~..;.._ __ Rear:. . · Re·quired . --,------St r-u ct u re, separation:: Reguired -------- 3 .. Lot Covet1:19,e: Re.quired -----------,-- Shown -----.,...----Shown ----'-'-----Shown --=-,----,-- Shown ------Shown --.,...----,--,--- Shown ------ 4. Height: Requtted · Shown -~-----------'-- 5. Parking: Spaces ·Required: -----------'----Shown --,----~- (bre.akdown ·by use~· for commercial ahd industrial .projects reqLJired) ;ResidEmtlar ·Gu.est ·spaces ;Re"quired --------=--------Shown _____ __,. . material re uired? DATE H:\ADMIN\COUNT~R\BldgPJnch~RevChk'lst Rev 9/01 Carlsbad Fire Department Plan Review Requirements Category: Tl , COMM Date of Report: 12-15-2005 Name: Address: Permit#: CB053861 PACIFIC INTERIOR SYSTEMS 6364 FERRIS SQUARE SAN DIEGO, CA 92121 Job Name: MALCOLM PIRNIE-2100 OFF TO OF Job Address: 1525 FARADAY AV CBAD Revi~OOby. '4~ ~S0MIL.bE,:;f,JJ,-"Tflte-Hem-ve,itrh1we-"8ttl:m'l1~e€ll-i410iei_;~-re-~0mp-lete. At this ti-me;-tms effioe oBiBils- assqt¼El:tel-y 08Beluet 8: FOi\7½0~,v tere,ete~the-app-~€00o@S-and/€>HfftF.lacwds-:-P-leaso fOYi:OV,.W ~ems--attaehed. P-lease-resubmit the necessary plans and,ler speoifieations, wi-t-ft ellaages "eloaded", -to this=offi:ee fur rev±~· afl:d awro:vah · Conditions: Cond: CON0000968 [MET] APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW Entry: 12/15/2005 By: GR Action: AP .. Carlsbad Fire Department Plan Review Requirements Category: TI , COMM Date of Report: 11-15-2005 Name: Address: PACIFIC INTERIOR SYSTEMS 6364 FERRIS SQUARE SAN DIEGO, CA 92121 Permit#: CB053861 Job Name: Job Address: MALCOLM PIRNIE-2100 OFF TO OF 1525 FARADAY AV CBAD Reviewed by: }:/) tUifJ/41.._;; INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0000881 1. Please provide one additional 2A:10BC fire extinguisher and mount on wall near open offices 210. Please show on page T-2. Entry: 11/08/2005 By: pp Action: CO Cond: CON0000890 2. The door swing direction for the doors to the reception area needs to be changed to swing outward in the direction of travel due to more than 50 people. Entry: 11/15/2005 By: pp Action: CO Carlsbad Fire Department Plan Review Requirements Category: TI , COMM Date of Report: 11-08-2005 Name: Address: Permit#: CB053861 PACIFIC INTERIOR SYSTEMS 6364 FERRIS SQUARE SAN DIEGO, CA 92121 Job Name: MALCOLM PIRNIE-2100 OFF TO OF Job Address: 1525 FARADAY AV CBAD Reviewed by: ~ INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0000881 1. Please provide one additional 2A:10BC fire extinguisher and mount on wall near open offices 210. Please show on page T-2. Entry: 11/08/2005 By: pp Action: CO i i . ·1 ,. ! l 1"1'.l .L.L.'10 r11A u...::r, 4JtJO '-.J.10 ______ ..!-. _ __._ ___________________ u_r. ..... n ii __ _ VOi &..~I V.L OFFICE USE ONLY H# __ ...,... ____ _ SAN DIEGO REGIONAL BP DATE ____ .....__,_ __ SA/M ______ _ APCD ______ _ HAZARDOU$ MATERIALS QUESTIONNAIRE Plan File#/Permlt# PART I; FIRE DEPARTMENT· HAiARDaus MATERIALS MANAGtMENI DIVISION; QCCl.,IPANCY CLASStftCATIQt':1 - Indicate by circling the item, whether your business will use, procass, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with Jurisdiction prior to plan submittal. · 1. Explosive or Blasting Agents 4. Flammable Solids 7. Pyrophorics 10. Cryogenics 13."Corrosives 2. Compressed Gases 5. Organic Peroxides 8. Unstable Reactives 11. Highly Toxic or Toxic Materials 14. Other Health Hazards 3. Flammable or Combustible Liquids 6. Oxidizers 9. Water Reactives 12. Radioactlves PAR! fl: SAN DIEGO COUNTY DEPARTMENT Of ENVJRQNMENTAL HE'ALTH • HAZA8DOl.,IS MATERIALS MANAGEMENT DIVISION IHMMQl: If the answer to any of the questions Is yes. applicant must contact the County of San Diego Hazardous Materials Management Division, 1255 Imperial Avenue, 3rd Floor, San Oiego, CA 92101. Telephone (6191 338-2222 prior to the iss1:1anca of a building Q CalARP Exempt department permit. I Date Initials FEES MAY SE REQUIRED Yes No 0 CalARP Required I 2. , Will your business dispose of Hazardous Substances or Medical Wasta ln any amount? Date Initials 1, § I b yo~ bu,Jooo, "'"'" oo th, ..,,,~, Odoof1hl, fo,ml 3. Will your business store or handle Hazardous Subst&nces in quantities equal to or greater than 56 gallons, 0 Ca!ARP Complete -_ 500 pounds, 200 cubic feet or carcinogens/reproductive toxins In any quantity? 4 . ~" Will your business use an existing or Install an 1,1nderground storage tank? I .... ,. Will your business store or handle Regulated Substances ICalARPl7 5. -Date Initials 6. "' Wlll your. business use or install a Hazardous Waste Tank Svstem (Title 22, Article 101 E8BI !Iii~ r..t:1 Ql!;GQ ~QUC:II):'. 81B ·EQLl.!,JIIO~S QQ~IBQ!. Ql~IRl~I If the answer to any of the questions is yes, applicant must contact the Air Pollution Control District, 9160 Chesapeake Drive, San Diego, CA 92123. Telephone 1 (858) 650-4550 prior to the issuance of a building department permit. YES NO ... . . . . 1. 0~ Will the Intended occupant Install or use any of the equipment listed on the Listing of Air-Pollution Control District Permit Categories, on the reverse side of this form? ?· DO !ANSWER ONLY IF QUESTION 1 rs YES.) WIii the subject facility be located within -1 ;ooo feet of the outer boundary of a school (I< through 1 Zl as listed In the current Directory of School and Community College Districts, published by the San Diego County Office at Education and the current California Private School Directory, compiled in accordance with provisions of Education Code Section 33190? 3. Does the buildin or structure for which this ermlt is re uested contain an friable asbestos? Name of Owner or Authorized Agent Oate CJn-e. Honk U,4t os FOR OFFICIAL use ONL y: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:~-----''--------------------------BY·-----------------------------''-------Oate: __ ..;._ ____________ _ EXEMPT OR NO f\JRTHEll 1NFOIIMATION REOUtREO Ret.EAseo FOR IIUtt.OING PERMIT 11\JT NOT FOR OCCUPANCY COUNTY•HMMO APCO COUNTY-HMMO APCO ... IIELE.a.SEO FOR OCCUPANCY COUNTY-HMMO APCO County o/ San -Oiego Department ol-Environmentat Heatth i /CERTIFICATE OF COMPLIANCE (Part 1 of 2) MECH-1-C I PROJECT NAME DATE Malcolm Pirnie 11/22/2005 PROJECT ADDRESS Emerald Lake Corporate Centre Suite 290 Carlsbad ----------- PRINCIPAL DESIGNER -MECHANICAL TELEPHONE Building Permit # Greater San Diego Air Conditioning Co. Inc. (619) 469-7818 ---------· DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Greater San Diego Air Conditioning Co. Inc. (619) 469-7818 Enforcement Agency Use GENERAL INFORMATION I DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 11-22-05 BUILDING TYPE IX] NONRESIDENTIAL PHASE OF CONSTRUCTION D NEW CONSTRUCTION METHOD OF MECHANICAL COMPLIANCE IX] PRESCRIPTIVE 4,965 Sq.Ft. D HIGH RISE RESIDENTIAL D D ADDITION D ALTERATION D D PERFORMANCE CLIMATE ZONE 7 HOTEL/MOTEL GUEST ROOM UNCONDITIONED (File Affidavit) PROOF OF ENVELOPE COMPLIANCE PREVIOUS ENVELOPE PERMIT D ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. +-L ICDicoicc:t:u~MiEjNirTAATTi1icoiNNiJAuunTri:HicoiFRt----------:::+sii~rnffi'ED~--=:::::;:;::;:-----------7DAJE~~i--;:::j ~ 1-----T--'--'.,..,,L"--. H'--'-""'-'ar'-'--'m.....,,o=n'------+n"'--:;;;:~~-------------1..~_.:__-1-/J-=U~ )- The Principal Mechanical Designer hereby certifies that t · oposed building design represented in this set of construction k documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other ,[S calculations submitted with this permit application. The proposed building has been designed to meet the mechanical cJ requirements contained in the applicable parts of Sections 100,101,102,110 through115, 120 through 125,142,144, and 145. D The plans & specifications meet the requirements of Part 6 (Sections 10-103a). D The installation certificates meet the re.quirements of Part 6 (10-103a 3). D The operation & maintenance information meets the requirements of Part 6 (10-103c). Please check one: (These sectionsofthe Business and Professions Code are printed in_full in the Nonresidential Manual.) D I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State o{Califomia as a civil engineer, or mechanical engineer or I am a licensed architect. D I affirm·that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. D I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structur~ or type of work described pursuant to Business and Professions Code sections 5537, 5538, and 6737.1. r PRINCIPAL MECHANICAL DESIGNER· NAME SI l'l'ATU Greater San Die o Air Conditionin L1q.#ir1SJ! Indicate location on plans of Note Block for Mandatory Measures 1/1/t?J, I ~---~----------------------'; INSTRUCTIONS TO APPLICANT IB! MECH-1-C: Certificate of Compliance. Part 1, 2, 3 of 3 are required on plans for all submittals. IB! MECH-2-C: Certificate of Compliance. Part 1, 2 of 2 are required for all submittals, but may be on plans. IB! MECH-3-C: Certificate of Compliance are required for all submittals with mechanical ventilation, but may be on plans. IBl MECH-4-C: Certificate of Compliance are required for all prescriptive submittals, but may be on on plans. C MECH-5-C: Mechanical Equipment Details are required for all performance submittals. '---__ E_ne_rg=y_P_ro_4_.0~by_E_n_er-"g'--yS_o_ft _____ U_s_e_r N_u_m_b_er_: _62_7_2 _______ Jo_b_N_um_be-"r: ______________ Page:1 of 10 fCERTIFICATE OF COMPLIANC.E (Part 1 of 2) MECH-1-C I PROJECT NAME DATE Malcolm Pirnie 11/2/2005 PROJECT ADDRESS Emerald Lake Corporate Centre Suite 290 Carlsbad Building Permit# PRINCIPAL DESIGNER· MECHANICAL TELEPHONE Greater San Diego Air Conditioning Co. Inc. (619) 469-7818 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Greater San Diego Air Conditioning Co. Inc. (619) 469-7818 Enforcement Agency Use GENERAL INFORMATION . DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 11-03-05 4,885 Sq.Ft. BUILDING TYPE [XI NONRESIDENTIAL D HIGH RISE RESIDENTIAL PHASE OF CONSTRUCTION D NEW CONSTRUCTION D ADDITION D ALTERATION METHOD OF MECHANICAL COMPLIANCE [Z] PRESCRIPTIVE D PERFORMANCE D D CLIMATE ZONE 7 HOTEUMOTEL GUEST ROOM UNCONDITIONED (File Affidavit) PROOF OF ENVELOPE COMPLIANCE D PREVIOUS ENVELOPE PERMIT D ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR T.L. Harmon The Principal Mechanical Designer hereby certifies that the proposed building design represented in this set of construe ion documents is con~istent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in the applicable parts of Sections 100, 101, 102, 110 through115, 120 through 125, 142, 144, and 145. 0 The plans & specifications meet the requirements of Part 6 (Sections 10-103a). D The installation certificates meet the requirements of Part 6 (10-103a 3). 0 The operation & maintenance information meets the requirements of Part 6 (10-103c). Please check one: (These sectionsofthe Business and Professions Code are printed in full in the Nonresidential Manual.) D I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, or mechanical engineer or I am a licensed architect. D I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. D I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structur or type of work described pursuant to Business and Professions Code sections 5537, 5538, and 6737.1. PRINCIPAL MECHANICAL DESIGNER· NAME Greater San Die o Air Conditionin Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT IBl MECH-1-C: Certificate of Compliance. Part 1, 2, 3 of 3 are required on plans for all submittals. IBl MECH-2-C: Certificate of Compliance. Part 1, 2 of 2 are required for all submittals, but may be on plans. IBl MECH-3-C: Certificate of Compliance are required for all submittals with mechanical ventilation, but may be on plans. IBl MECH-4-C: Certificate of Compliance are required for all prescriptive submittals, but may be on on plans. D MECH-5-C: Mechanical Equipment Details are required for all performance submittals. EnergyPro 4.0 by EnergySoft User Number: 6272 Job Number: