HomeMy WebLinkAbout1525 GRADY PL; ; CB940157; Permit03/09/94 12:16
1 Page 1 of 1
B U I L D I N G P E R M I T Permit No : CB940157
Project No: A9400225
Development No:
Job Address: 1525 GRADY PL Suite:
Permit Type: RESIDENTAL ADD/ALT
Parcel No: 207-021-53-00 Lot#:
Valuation: 4,410
Construction Type: VN
Occupancy Group: Reference#:
Description: 210 SF WORK SHOP
Appl/Ownr : KELNHOFER, DORTHY
1525 GRADY PLACE
CARLSBAD, CA . 92008
619 434-1128
Status: ISSUED
Applied: 02/14/94
Apr/Issue: 03/01/94
Entered By: MDP
*** Fees Required *** *** Fees Collected & Credits ***
Fees:
Adjustments:
Total Fees:
Fee description
Building Permit
Plan Check
Strong Motion Fee
* BUILDING TOTAL
167.00
.00
167.00
Enter "Y" for Plumbing
Gas Piping System
Issue Fee
* PLUMBING TOTAL
Enter "Y" for Electric Issue Fee
Enter "Y" for Remodel
* ELECTRICAL TOTAL
>
>
> >
Total Credits:
Total Payments:
Balance Due:
Units Fee/Unit
1 7.00
Enter 'Y' for Mechanical Issue Fee>
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
. 0 0 ti
140.00
27.00
Ext fee Data
72.00
47.00
1.00
120.00
20.00 Y
7.00
27 .00
10.00 Y
10.00 Y
20 .00
N
~ ·-...... ---~•----------------
PERMIT APPLICATION
City of Carlsbad Building Departaent
2075 Las Pal1118S Dr., Carlsbad, CA 92009 (619) 438-1161 ESf. VAL
PLAN CK DEPOSIT
VAIJD. BY
I. PEkMi I liPE DATE
A -U Commercial Li New Building U lenant Improvement
B -• Industrial • New Building • Tenant Improvement
C -Ci1(esidential • Apartment • Condo IB'Single Family Dwelling reiddition/ A1teration
U Duplex • Demolition • Relocation • Mobile Home ~lectrical • Plumbing
U Mechanical • Pool • Spa • Retaining Wall • Solar • Other
2. PROJl!Cf INFORMATION FOR OFFICE USE ONLY
ress
Nearest Cross Street
am umr fVJi ftf,{O. a
CHECK BEWW IF S0BMII 1£0: cc± 7 2 -;s-JtP fJI!) 2ZR7 u~ 3 7611: .-I ,
• 2 Energy Cales • 2 Structural Cales • 2 Soils Report • I Addressed Envelope
ASSESSOR'S PARCEL Ade/ 5h0P EXISTING USE
DESCRIPTION OF WORK
SQ. IT. ~ kll # OF storuEs ' 3. WN IACI PERSON {IC dnferent from apphcant)
NAME ADDRESS
CITI STATE ZIP OODE DAY TELEPHONE
5. PkOPhll
NAME ADDRESS
CITI ~ abo,10. STATE ZIP CODE DAY TELEPHONE
6. wN~k
NAME ADDRESS
CITI STATE ZIP CODE DAY TELEPHONE
STATE UC.# LICENSE CIASS CITI BUSINESS UC. #
CITI STATE ZIP OODE DAY TELEPHONE STATE UC,#
7. WOltkERS' WUPF!NSXJIUN
Workers' Compensation Declaration: I hereby afhrm that I have a cert1hcate of consent to self-msure issued by the Director of lndustnal
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY POLICY NO. EXPIRATION DATE
•
D
Certthcate of Exemption: I certify that m the ~rfol"!flance of the work for which this penmt 1s issued, I shall not employ any person m any manner
as .tC\._ ~su1>kst to/the Workers• Com sa _on Laws of California.
j /L C /' d;, .f :.'t, L / 1/t 1/'/ NATIJ 7·L DATE '
e o owmg reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale.).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects
with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section ________ Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's Llcense Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.S by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). c.~~,--DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 25505, 25S33 or 25S34 of the Presley-Tanner Hazardous Substance Account Act? •YES •NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? •YES •NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? •YES •NO
IF ANY OF 11IB ANSWERS ARE YES, A FINAL CERTIFICATE OF CXOJPANCY MAY NOT BE ISSUED AITER JULY I, I 989 UNLESS 11IB APPUCANT
HAS MET OR IS MEIITING 11IB IIF.QUIREMENT5 OF THE OFFICE OF EMERGENCY SERVICES AND 11IB AIR POlllJTION CDNTilOL DISfRICT.
9. WNSIROCJJUN mNDING AGENCY
I hereby afhrm that there 1s a construction lend mg agency ior the performance of lbe work for which lb1s permit ts issued {Sec 309? {I) LlvJJ Code).
rn'.-1'=~-riJjnifi&~ION LENDER'S ADDRESS
I certify that I have read the application and state that the above mformatJon 1s correct. I agree to comply with all City ordmances and State laws
relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE ID SAVE INDEMNIFY AND KEEP 1lARMIB'iS 11IB C11Y OF CA111SBAD AGAINSI" ALL IJABILlTIES, JUDGMENTS, CDSfS
AND EXPENSES WIIlCH MAY IN ANY WAY MDUJI! AGAINSI" SAID Cl1Y IN CDNSEQUENCE OP 11IB GRANTING OF 11IlS PERMIT.
OSHA; An OSHA permit is required for excavations over S'0" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 36S days from the date of such permit or if the building or work authorized by
such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Unifo7•B/tng Code).
APPLICA)'T'S s!~N~TU~ ./ ! .· .· DATE: /11,' l:t/ ,,-1 II,, >¼c , ld/;;;t/t (
/ WHITE: File YELLOW: Applicant PINK: Finance
/
PERMIT# CB940157
DESCRIPTION: 210 SF WORK SHOP
TYPE: RAD
JOB ADDRESS: 1525 GRADY PL
APPLICANT: KELNHOFER, DORTHY
CONTRACTOR:
OWNER:
REMARKS: MW/BENTON
SPECIAL INSTRUCT:
TOTAL TIME:
LVL DESCRIPTION
CITY OF CARLSBAD
INSPECTION REQUEST
FOR 06/22/94
STE:
INSPECTOR AREA PD
PLANCK# CB940157
OCC GRP
CONSTR. TYPE VN
LOT:
PHONE: 619 434-1128
PHONE:
PHONE:
INSPECTOR --~'---~7'----------7
ACT COMMENTS CD
14 ST Frame/Steel/Bolting/Welding b.!l...S:-______________ _
-----"-Hi::...::Ltno ........ R _______ ~ -------------
--------------------
--------------------
***** INSPECTION HISTORY*****
DATE
061694
041494
031794
DESCRIPTION
Final Combo
Gas/Test/Repairs
Ftg/Foundation/Piers
ACT INSP
CO PD
AP PD
AP PD
COMMENTS
PLA11 am;ii: 10,_ . ...:.9...,_'-f_-_,_/-=S_7.___ _____ _
J1JRISD1cnm, c:rn !I' cm WP
ro,. ___________________ _
EIICLOSURIIS:. ______________ _
fLllllR AHL\: 2. / 0 fl
SIORIIS:.__,_/ ------>\Yk<F-• --
mc:cm,. ___ ...Jµ./.Q~~ ·;4.---
RDWIIS: WuP-k sk!f .•J;' ~\:
PI.All WrPPitW! PDT
cm w anwr
SJPII r,vmy m, mn,p: PfPIIFI
Date plans received by jurisdiction:
Date initial plan check completed:
______ By: ____________ _
Applicant contact person:
_________ Telephone:, ________ _
Plan check. is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances by the Planning Department,
Engineering Department or other departments.
Present california law mandates that residential
construction comply with Title 24 and the following
model codes:
1991 UBC (eff. 8/14/92)
1991 UPC (eff. 8/14/92)
1990 NEC (eff. 7/1/91)
1991 UHC (eff. 8/14/92)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
The circled items listed need clarification,
modification or change. All items have to be
satisfied before the plans will be in conformance
""ith the cited codes and regulations. Per Sec.
303(c), 1991 Uniform Building Code, the approval of
the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, note on this list
(or a copy} wh•ra each correction item has been
addressed i,,., plan sheet, specification, etc. Be
sure to •nclost the marked up list when you submit
the revised Plans,
lllm: P-IIIIIIIIIIS AKI llO'l lR Sliil(iiM.!i AS PAGIS IL\Vllll 11> IDNS llll!DJIIG o-tRD·II,m WIRF DIIl'J'ID
List No. 2, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1991 UBC)
49. Provide spiral stairway details, per Section
3306 (f): .
a. Minimum nm is 7 1/2 inches measured at a
point 12· inches from where the treads are
the narro\oo'est.
b. Maximum rise is 9 1/2 inches. Maximum
clear opening between risers is 6 inches.
C •
d.
Minimum headroom is 6 feet 8 inches
The tread must provide a clear walking
area ceasuring at least 26 inches from the
outer edge of the supporting column to the
iMer edge of the handrail.
50. Spiral stai.t"'\<,·ays may not be used for required
exits ¥i'hen the area served is greater than 400
sq. ft. Section 3306 (f).
51. Provide I.C.B.O. Research Report and number for
metal stair;,.·ay, or submit plans and
calculations and approved fabricator registered
with the building department or note that the
stain.·ay fabrication plans shall be submitted
to and approved by the building official prior
to installation.
52. Exterior stair,.:ays shall not project into the 3
foot setback from the property lines. Section
3306 (m).
53. The ,·alls and soffits of the enclosed usable
space under interior stairs shall be protected
on the enclosed side as required for one-hour
fire-resistive construction. Section 3306 (1).
54. W1whin units, show that corridors have a mi · width of 36 inches. Section 3305 (b).
JJ ROOrn«;
~Specify roof slope.
56. Roof slope is not adequate for roof type
specified. Iable 32-B, D and E.
57. Specify roof material and application.
Chapter 32.
58. Specify I.C.B.O. or· U.L. approval number for
roof materials not covered in U.B.C., e.g.,
tile, etc. Section 107.
59. Specify minimum l/4 inch per foot roof slope
for drainage or design to support accumulated
water, Section 3207 (a) a.nd Section 2305 (f).
60, Show roof drains and overflows. Section 3207.
5/22 92
61.
62.
Provide skylight details to show compliance
with Sections 3401 and 5207 or provide
I.C.B.O. approval number.
Plastic skylights must be separated from each
oth r by least 4 feet, unless they are over
th am room and their combined area does not
100 square feet (or ZOO square feet if
plastic is a "CCI" c-.aterial). Section
5207 (a) 6.
~, Show attic ventilation. !-!inimum vent area is V 1/150 of attic area or 1/300 of attic area if
at least 50% of the required \.'ent is at least
3 feet above eave vents or cornice vents.
Show required area and area provided.
64.
65.
66.
Section 3205 (c).
Provide fireplace
construction to
standard drawing.
construction details or note
be per attached fireplace
Chapter 37.
Show anchored veneer support and connections
attached to wood in Seismic Zones 3 and 4,
comply with Section 3006 (d)l and Section 2515
(a). Show ties, #9 i.,.-ire in horizontal
joints, etc.
Show height and construction
concrete and masonry walls.
26.
details of all
Chapters 24 and
67. Show floor and roof connections to masonry and
concrete •alls. Connection shall resist 200
pounds Per lineal foot or the actual design
load, whichever is greater. Cross grain
tension or bending in wood ledgers is not
permitted.
Section 2310.
68. Show a minimum 2" air space and flashing
between planter and building walls.
Section 2516 (c) 7.
GIJlAGI AIID CARP0R7S
69. Garage requires one-hour fire protection on
the garage side of walls and ceiling cortE10n to
the dwelling. Table 5-B, Section 503 (d).
70. All elements supporting floor above garage,
including ""·alls supporting floor joists, must
have one•hour fire-resistive protection on the
garage side. Section 503 {b)
71. Show a self-closing door, either 1-3/811 solid
core or a listed 20·minute assembly, for
openings between garage and dwelling.
Section 503 {d).
5
94.
95.
96.
97.
Show ,on the plans stepped footin_gs for slopes
steeper than 1:10. Section 2907 (c).
Show minimum 1811 clearance from grade to
bottom of floor joists and minimum 1211
clearance to bottom of girders. Section 2516
(c) 2.
Show pier size, spacing and depth into
undisturbed soil. Table 29-A.
Show minimum W1derfloor access of 1811 x 24".
Section 2516 (c)2.
98. Show minimum underfloor ventilation equal to l
sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c) 6.
l'RAKDC
99. Show •••all bracing. Every exterior wood stud
wall and main cross-stud partition shall be
braced at each end at least every 25 feet of
length with 1 x 4 diagonal let-in braces or
equi\-alent. Section 2517 (g) 3, !able 25-V.
100. In 2-story buildings, shear pan,ls at the
first story (at least 48 inches in width)
shal 1 be located at each end or as near
thereto as possible and comprise at least 25
percent of the linear length of the wall, or
provide design. Section 2517(g)3, !able 25-V.
101. cross bridging or blocking. Floor joists
af rs 12" or more in depth shall be
ed laterally by bridging at intervals
.,,.,,,r-cee · g 8 feet, unless both edges are
fl"l'-"'_.'...-:Lne. Sec. 2506 (h),
ow blocking at ends and at supports of floor
joists, rafters and trusses at exterior walls.
Section 2517 (d) 3, 2517 (h) 7.
103. Bearing partitions, perpendicular to joists,
shall not be offset from supporting girders,
beams, walls or partitions, more than the depth
of the joist. Section 2517 (d) 5.
104. Show rafter ties. Rafter ties shall be spaced
not more than 4 feet on center and be just
above the ceiling joists, where rafters and
ceiling joists are not parallel. Section 2517
(h) 5.
105. Show rafter purl in braces to be not less than
45 degrees to the horizontal.
Section 2517 (h) 6.
5/22/92
106. Show double top plate •·ith minimum 48" lap
splice. Section 2517 (g) 2.
107. Show nailing will be in compliance with Table
25-Q.
108. Show or note fire blocks at the following
locations per Section 2516 (f):
a. In concealed spaces of stud ..,·alls and
partitions, including furred spaces, at
the ceiling and floor levels and at 10
foot intervals both vertical and
horizont.al;
b. At all interconnections between concealed
vertical and hori:.ontal spaces such as
occur at soffits, drop ceilings and cove
ceilings;
c. In concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and inline
\dth the run of stairs if the -..·alls W"lder
the stairs are unfinished;
d. In openings around vents, pipes, ducts,
chimneys, fireplaces and similar openings
which afford a passage for fire at
ceiling and floor levels, with
noncombustible materials; and
e. At openings between attic spaces and
chimney chases for factory-built
chimneys.
109. In duplexes, draft stops shall be provided in
floor-ceiling assemblies and attics in line
with ,,.-alls separating units and separating
units from common areas. Section 2516(f)4 .
110. Show stud size and spacing. Ma.xi.mum allowable
stud heights: Bear'ing ,·all: 2 x4 and 2 x 6
max. 101 ; Non-bearing: 2 x 4 max. 14 1 , 2 x 6
max. 20'. !able 25-R-3.
111. Studs supporting t""o floors, a roof and
ceiling must be 3 x 4 or 2 x 6 at 16" o.c.
!able 2S·R·3.
112. Note on A.I.!.C. Certificate of Compliance for
glued laminated wood members shall be given to
the building inspector prior to installation.
Section 2505.
113. Detail all post•to•beam and post-to-footing
connections and reference the detail to the
plan. Section 2516 (m).
114. Detail shear transfer connections, including
roof and floor dia.phragcs, to shear walls.
Section 2513.
7
115. Specify nail size
walls', floor and
required blocking.
dimension ratios.
Section 4714 (d)J.
and spacing for all shear
roof diaphragms. Indicate
Maintain maxi-diaphragm
[Tables 25 I, J, K and
116. Provide truss details and truss calculations
for this project. Specify truss identification
numbers on the plans.
117. Show 1/2" mini.cum clearance between top plate
of interior partitions and bottom chord of
trusses. (Io ensure loading will be as
designed).
118. Provide roof fra.cing plan and floor framing
plan. Section 302 (d).
119. Provide framing sections through
t;J?an 302 (d).
Specify all header sizes for opening over 4 1
wide. Section 2517 (g) 5.
121. Provide calculations for main vertical and
horizontal framing members and post footings.
Section 302 (b).
122. Provide calculations for lateral loads, shear
panels, shear transfer and related. Section
302 (b).
123. In Seismic Zones 3 and 4, the allowable shear
"all values for dry,.,all in Table 47-I must be
reduced 50 percent Wen considering earthquake
loads. This does not apply to wind loads.
Footnote 1.
124. Show on the plans all structural requirements
developed in the structural calculations.
Section 302 ( d). (See cements below or at
end.)
125. Columns and posts located on concrete or
masonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be
supported by concrete piers or metal pedestals
projecting above floors unless approved wood
of natural resistance to decay or treated wood
is used. Section 2516 (c) 4.
126. Individual concrete or masonry piers shall
project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood is used.
Section 2516 (c) 4.
5/22/92
S ow location of attic access with a mini.mum
size of 2Z11x30", unless the maxi.mum vertical
headroom height in the attic is less than 30".
Access must be provided to each separated
attic area, shall be located in a halh,;ay or
other readily accessible location and 3011
headroom clearance is required above the
opening. Section 3205(a).
128. Show location of attic access with minimum
size 2211 x 3011 • Section 3205.
129. Detail truss layout for 3011 x 3011 attic
access, if required for equipment in the
attic, and detail 3011 x 3011 clearance th.rough
truss •;ebs.
130. Specify plywood and/or particle board
thickness, grade and panel span rating.
Table 25-S.
131. Show plywood sheathing over exposed eaves, or
other weather exposed areas, is "bonded with
exterior glue. 11 Plywood used for exterior
wal 1 covering shall be the exterior type.
Section 2516 (i), Z516(g)3.
132. When roof pitch is less than 3:12, design
ridge as a beam. Section 2517 (h).
133. Ridges, hips, and valleys shall be
one size larger than supported
Section 2517 (hJ 3.
at least
rafters.
134. In open beam construction, provide strap ties
across the beams at the ridge support.
Section 2501 (b).
135. If foundation cripple wall studs are less
than 1411 high, framing shall be solid
blocking:, or sheathed with pl}",,'ood. Section
2517 (g) 4.
136. Cripple wall studs exceeding 4 feet in height
shall be 3 inch by 4 inch or 2 inches by 6
inches when supporting 2 stories.
Section 2517 (g) 4.
137. Note on the plans that "all weather-exposed
surfaces shall have a weather-resistive
barrier to protect the interior wall covering
and that exterior openings shall be flashed in
such a manner as to make them weatherproof11 •
Section 1708.
All heating, ventilating, and cooling systems and
appliances shall comply with the Uniform Mechanical
Code.
8
185. Show on the Title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 112383.
187.
188.
189.
All new residential buildings, including
additions, require a soils report. Please
submit two copies.. Exception: If a room
addition is limited to one story and 1000 sq.
ft. in area, then a soils report is not
required. Esgil Corporation will advise the
City to place their soils notice stamp on the
plans.
Heavy timber framing, minimum 611 x 1011 beams
and minimum 811 x 811 post, for the structural
beam and column supporting the fire separation
between the garage and living area above, is
acceptable if shown on the plans. (city
policy).
All structures require a Class B roof covering,
except room additions. If a room addition
covers all of the existing building (2nd story
addition), then the above exception doesn I t
apply.
City Ordinance 9792
spaces/wiit with clear
washing machines, etc.
requires two parking
area of 20'x20' i.e. no
Show compliance.
190. Only tank-type water closets that use an
average of 1. 6 gallons of water per flush or
less, and urinals and associated flushometer
valves, that use an average of 1 gallon of
water per flush or less shall be installed in
new construction. These provisions shall
apply to existing buildings only when toilets
are being replaced in existing bathrooms or
installed in new bathrooms.
191. Please see additional corrections, or remarks,
on the following page.
192. To speed up the recheck process, note on this
list (or a copy) where each correction item
has been addressed, i.e. , plan sheet, note or
detail number, calculation page, etc.
193. Please indicate here if any changes have been
made to the plans that are not a result of
corrections from this list. If there are
other changes, please briefly describe them
and where they are located in the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
____ Yes ____ No
IE£ C,fy
8 11 92
If you have any questions regarding these plan check items, please contact. ________ _
• If you have any questions
regarding City Building permit procedures, please
contact Carter Darnell at the City of Carlsbad,
2075 Las Palmas Dr., telephone 619/438-1161.
Thank you.
Enclosures:
1.
z.
3.
t1') 1 'jkt
9,-,..,
13
1. Please make all corrections on the original
tracings and submit two new sets of prints, to:
2. Please make all corrections on the original
tracings and submit ·two new sets of prints, to:
3.
4.
5.
6.
a.
9.
The jurisdiction's building department.
Indicate on the Title Sheet of the plans, the
name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302(a)7.
All sheets of plans must be signed by the
person responsible for their preparation.
(california Business and Professions Code).
Plans, specifications and calculations shall be
signed by the California state licensed
engineer or architect responsible for their
preparation, for plans deviating from
conventional wood frame construction. Specify
expirati m date of license. (California
Business and Professions Code).
Specify on the Title Sheet of the plans the
gross floor area of each element of this
project including dwelling, garage, carport,
patio, deck and balcony. Section 302(d).
Provide a statement on the Title Sheet of the
plans that this project shall comply with Title
24 and 1991 UBC,. UMC and IJPC and 1990 NEC.
-l. ' ', --
Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes. Show finish floor elevations and
show elevations of adjacent finish grade.
Show drainage patterns with minimum slopes.
Section 302( d).
Indicate distance from property lines to
proposed construction. Section 302(d),
10. Show on the title sheet all structures, pools,
walls, etc. included under this application.
Any portion of the project shown on the site
plan that is not included •·ith the building
permit application filed should be clearly
identified as "not ·included.11
11. Clearly show if the lower le,·el is a basement
or a story, based on the definitions in
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension
the distance to the floor above, for story
determination.
12. On the cover sheet of the plans, specify any
items requiring special inspection, in a
format similar to that sho•n below or sticky
back.
REQUIRED SPECIAl INSPECTIONS
In addition· to the regular inspections, the
following checked items will also require
Special Inspection in accordance with Sec. 306
of the Uniform Building Code.
IIEl1
SOILS COMPLIANCE
PRIOR IO
FOUNDATION INSP.
SIRUCIURAl CONCRETE
OVER 2500 PSI
PRESIRESSED STEEL
FIELD WELDING
HIGH SIRENGTII BOLTS
EXl'ANSION ANCHORS
SPECIAL MASONRY
SPRAYED ON FIRE
PROOFING
PILES/CAISSONS
DESIGNER-SPECIFIED
OTHER
REQ. IF
CHECKED
nu fRQ!fiFl\ulll
REMARKS
13. Exterior walls closer than 3 feet to property
lines shall be one-hour rated construction and have no openings. Table S-A,
8/5 92 2
14. Exterior w.alls closer than 3 feet to a
property line shall have 30 inch parapetJ "hen
the f'loor area per floor exceeds 1,000 square
feet. See Section 1710 for possible exception.
15. Projections, including eaves, may not extend
more than 12 inches into the 3 foot setback
from the property line. Section 504(b).
16. Eaves over required windows shall be not less
than 30 inches from the side and rear property
lines. Section 504(a).
17.
18.
19.
Projections, including eaves, shall be one-hour
fire-resistive construction, heavy timber or of
noncombustible oaterial if they project into
the 3' setback area from the property line.
Section 1711.
Plastic skylights shall not be installed within
that portion of a roof located within a
distance to property line where openings in
exterior walls are prohibited or required to be
protected. Section 5207 (a) 7.
Show locations of permanently wired smoke
detector with battery backup:
a. Inside each bedroom.
b. Centrally located in corridor or area
giving access to sleeping rooms.
c. On each story.
d. In the basement, if part of the dwelling
unit.
e. When sleeping rooms are upstairs, at the
upper level in close proximity to the
stair.
f. In rooms adjacent to hallways serving
bedrooms, when such rooms have a ceiling
height 24 inches or more above the
ceiling height in the hallway.
NOTE: Detectors shall sound an alarm audible
in ill sleeping areas of the unit. Section
1210.
When the valuation of a room addition or
repair exceeds $1,000, or when sleeping rooms
are created, smoke detectors shall be provided
~t --fi~isting bedrooms per item 19 above.
Section 1210.
21. Habitable rooms, other than kitchens, shall
contain at least 70 square feet of floor area..
At least one room shall have not less than 120
square feet of floor area. Section 1207 (b).
22. No habitable room, other than a kitchen, sh.all
be less than 7 1011 in any dimension. Section
1207 (c).
5/22/92
23. Sleeping rooms shall have a window or exterior
door for emerrncy exit. Sill height shall
not exceed 441 above the floor. The ._.indow
must have an openable area of at least 5. 7
square feet with the minimum openable width
2011 and the minimum openable height 24".
Section 1204.
24. Basements in dwelling units shall cornly ...,ith
the above (even if not designated as sleeping
rooms). Section 1204.
25.
26.
27.
28.
29.
30.
Window area must be at least 1/10 of the floor
area and a minimum of 10 square feet per
Section.1205 (b). Appears to be deficient in
Openable window area in habitable rooms must
be 1/20 of the floor area and a minimum of 5
square feet. In bathroocs, laundry rooms and
similar rooms 1/20 of area is required and
minimum is 1.s sq. ft. Section 1205 (c).
At least 1/2 of the comon wall must be open
and have an opening not less than 25 sq. ft.
nor one tenth of the floor area of the
interior room if light and ventilation is
being supplied from an adjacent room.
Section 1205 (a).
Required windows shall not open into a roofed
porch unless the ceiling height is at least 7
feet, the longer side is at least 65% open,
and the porch abuts a street, yard or court.
Section 1205 (a).
Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, "''ater closet compartments, laundry
rooms and similar rooms if required openable
windows are not provided. Section 1205 (c).
Note that the discharge point for exhaust air
will be at least 3 feet from any opening into
the building. Section 1205(c).
31. Ductless fans cannot·be used in bathrooms if a
tub or shower is present. Section 1205(c).
32. Show that ceiling height for habitable rooms
is a minimum of 7'6". Section 1207 (a).
33. Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a.
minimum of 7 1011• Section 1207 (a).
34. Dimension on the plans 3011 clear width for
"'·ater closet compartments and 24" clearance in
front of water closet. Section 511 (a).
3
City of Carlsbad • ¥i a.;; 044 a; n-1 •14 •ti;;, ei4 ,; a
,;2-4-l!?f BUILDING PI.ANCHECK CHECKLIST ,,-,4 oL.1;~-7 DATE: 1 PLANCHECK NO. L/J / I_,, ...) Tl
BUILDING ADDRESS: ./~ 5 C?tz'Af// //4-cC
PROJECT DESCRIPTION : A-pt) c:210 f tf@-_ MLK -5.h6p ,
ASSESSOR'S PARCEL NUMBER: o<o 2--b 1.,,,/-S-3 EST. VALUE ~ ½'o
/.Ar 3 -/J1 7737 Ct J.Z:-~GINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items
after this date, including field modifications, must
be reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to
comply with instructions in this report can result in
suspension of permit to build.
1st CHECK By: _______ _ Date:
2nd CHECK By:. _______ _ Oate:
3rd CHECK By:. _______ _
ATTACHMENTS
D Dedication Application
D Dedication Checklist
Date:
DENIAL
Please see the attached report of deficiencies
marked with D Make necessary corrections to
plans or specifications for compliance with
applicable codes and standards. Submit corrected
plans and/or specifications to this office for review.
By: __________ Date: ___ _
By: -~-------Date: ___ _
By: Date: ---------------
CONTACT PERSON
D Improvement Application
D Improvement Checklist
D Future Improvement Agreement
D Grading Permit Application
NAME: ______________ _
D Right of Way Permit Application
D Sewer Fee Information Sheet
ADDRESS: ______________ _
PHONE: ______________ _
A-4
P: DOCS CHKLS BP0001.FRM REV 12/17/93
2075 Las P a lmas Dr.• Carlsbad, C A 92009-1576 • (619) 438-11 6 1 • FAX (619) 438-0894
t BUILDING PLANCHECK CHECKLIST
SITE PLAN
1 ~+.1Ld✓ 3rd✓ ~ •' D 1. Provide a fully dimensioned site plan drawn to scale. Show:
•
•
•
A. North Arrow D. Property Lines Easements
B. Existing & Proposed Structures E. Easements
F. Right-of-Way Width & Adjacent Streets C. Existing Street Improvements
2. Show on site plan:
A. Drainage Patterns C. Existing Topography
B. Existing & Proposed Slopes
3. Show on a section drawing or include a note stating that there is a minimum of 6"
difference between the finished floor and the finished grade elevation adjacent to the
structure.
4. Include note: "Surface water to be directed away from the building foundation at a 2%
gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)."
[Per 1985 UBC 2907(d)5].
On graded sites, the top of any exterior foundation shall extend above the elevation
of the street gutter at point of discharge or the inlet of an approved drainage device
a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.).
5. Include on title sheet
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include: Total
building square footage with the square footage for each different use, existing sewer
permits showing square footage of different uses (manufacturing, warehouse, office,
etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
P:\DOCS\CHKLST\BP0001,FRM Page 1 of 4 REV 12/17/93
BUILDING PLANCHECK CHECKLIST
DISCRETIONARY APPROVAL COMPLIANCE 1t✓ 2nd✓ 3rd✓
rA D O 6. Project does not comply with the following Engineering Conditions of approval for ,-, Project No. ________________________ _
Conditions were complied with by: ______ _ Date: _______ _
DEDICATION REQUIREMENTS
7. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and for
remodels with a value at or exceeding $ ______ -pursuant to Code Section
18.40.030.
Dedication required as follows: _________________ _
Attached please find an application form and submittal checklist for the dedication
process. Provide the completed application form and the requirements on the
checklist at the time of resubmittal.
Dedication completed by ____________ _ Date: ____ _
IMPROVEMENT REQUIREMENTS
D D O ea. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the construction
exceeds ,._ ________ -pursuant to Code Section 18.40.040.
Public improvements required as follows: ______________ _
Please have a registered Civil Engineer prepare appropriate improvement plans and
submit them together with the requirements on the attached checklist for a separate
plancheck process through the Engineering Department. Improvement plans must be
approved, appropriate securities posted and fees paid prior to issuance of permit.
Attached please find an application form and submittal checklist for the public
improvements requirements. Provide the completed application form and the
requirements on the checklist at the time of resubmmal.
Improvement Plans signed by: __________ _ Date: ----
P:\DOCS\CHKLS1\BP0001.FRM Page 2 of 4 REV 12/17/93
I
1st✓ 2nd✓ 3rd✓
DD D
BUILDING PLANCHECK CHECKLIST
Sb. Construction of the public improvements may be deferred pursuant to code Section
18.40. Please submit a recent property title report or current grant deed on the
property and processing fee of $. _________ so we may prepare the
necessary Future Improvement Agreement. This agreement must be signed, notarized
and approved by the City prior to issuance of a Building Permit.
Future public improvements required as follows: ___________ _
Improvement Plans signed by: ___________ _ Date:, ____ _
D D D Sc. Enclosed please find your Future Improvement Agreement. Please return signed and
notarized Agreement to the Engineering Department.
D D
D D
I•
D
•
D
•
Future Improvement Agreement completed by: ____________ _
Date:, _______ _
Sd. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction of
the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section 11.06.030
of the Municipal Code.
9a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
9b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be Submitted together with the completed application form attached.
NOTE: The Grading Permit must be issued and rough grading approval obtained prior
to issuance of a Building Permit.
Grading Inspector sign off by: Date:
9c. No Grading Permit required.
BUILDING PLANCHECK CHECKLIST
P:\DOCS\CHKLST\BP0001.FRM Page 3 of 4 REV 12/17/93
MISCELLANEOUS PERMITS
10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are not
limited to: street Improvements, trees, driveways.
A separate Right-of-Way permit issued by the Engineering Department is required for
the following: ______________________ _
Please complete attached Right-of-Way application form and return to the Engineering
Department together with the requirements on the attached Right-of-Way checklist, at
the time of resubmittal.
11. A SEWER PERMIT is required concurrent with the building permit Issuance. The fee
is noted in the fees section on the following page.
12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial
Waste Permit Application Form and submit for City approval prior to issuance of a
Permit.
Industrial waste permit accepted by:_______ Date: ___ _
P:\DOCS\CHKLS1\BP0001.FAM Page 4 of 4 REV 12/17/83
• • w w • • " "
~
~\ I
~ J; J;
;;; N
" -.., ~ ~ ~ u u ·~ • • " " ~ u u
C i • ... ...
• w • " I
J;
"' -~ ll " u
! ...
PI-'NNING CHECI<LlSf
Plan Check No. ?'f-I 57 Address --'-/-=-S-.:2..:..S___,G~r_,,a..::..,Jy,_......!...P_I. _____ _
Planner DAVID RICK
(Name)
Phone 438-1161 ext. _4_3_2_8 ___ _
APN: ---=J,,._o~7L..--=:0::.:2::::.._:_I -...J6"-'3~-------------
~ci~~~~-~R~e~J_._a~~~~~~L•--------
zone ~I Facilities Management Zone /
CFO C out # c (If property m, complete SPECIAL TAX CALCULATION
WORKSHEET provided by Building Department.)
Legend
l2J Item Complete
~ Item Incomplete • Needs your action
1, 2, 3 Number in circle indicates plancheck number where deficiency was
identified
t10 0 Environmental Review Required: YES _ NO _L_ 1YPE __ _
DATE OF COMPLETION: ____________________ _
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval ______________________ _
do • Discretionary Action Required: YES NO J1YPE __ _
APPROVAIJRESO. NO. ___ DATE: _____ _
PROJECT NO. ___ _
OTHER RELATED CASES: ____________________ _
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval ______________________ _
§ 0 0 c:alifomia Coastal Commission Permit Required: YES / NO _
DATE OF APPROVAL:
San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725
(619) 521-8036
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval------------'-----------
ri O O Inclusionary Housing Fee required: YES _ NO /
(Effective date of Inclusionary Housing Ordinance -May 21, 1993.)
cl'••
ci'o •
ef••
000
EJ ••
ab •
Site Plan:
Zoning:
1.
2.
1.
2.
3.
4.
0 0 0 Additional Comments
Provide a fully dimensioned site plan drawn to scale. Show: Nonh
arrow, property lines, easements, existing and proposed structures,
streets, existing street improvements, right-of-way width, dimensioned
setbacks and existing topographical lines.
Provide legal description of property, and assessor's parcel number.
Setbacks:
Zo' Zv I
Front: Required Shown
Int. Side: Required ;:; It?' Shown 10 7 rr2'
Street Side: Required ,.-tr Shown #~
Rear: Required 'N Y2.' Shown ?,c.)' +
Lot coverage: Required f: q ol O Shown ~L/{}f,
Height: Required 3d Shown 13/
Parking: Spaces Required Z r .. r Shown ty,'( t ·
Guest Spaces Required Shown
-------------------------
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER~ DATE ~ ~
PLNCK.FRM
STATE OF CALIFORNIA-THE RESOURCES AGENCY PETE WILSON, Go~mor
CALIFORNIA COASTAL COMMISSION
SAN DIEGO COAST AREA
J n 1 CAMINO DEL RIO NORTH. SUITE 200
SAN DIEGO, CA 92108-1725
619) 521-8036 EXEMPTION LETTER
DATE: 111 au.I 19, (f <if _
Z, v c e /2 N tr v@-/I:, e ~ AA o{e r NAME:
LOCATION:
PROJECT:
This is to certify that this location and/or proposed project has been
reviewed by the staff of the Coastal Commission. A coastal development permit
is not necessary for the reasons checked below.
The site is not located within the coastal zone as established by the
California Coastal Act of 1976, as amended. ·
@ .
.
__ The pro.posed development is included in Categorical Exclusion No. ----adopted by the California Coastal Commission.
__ The proposed development is judged to be repair or maintenance activity
not resulting in an addition to or enlargement or expansion of the object
of such activities (Section 30610(d) of Coastal Act).
The proposed development is an improvement to an existing single family
residence (Section 30610(c) of the Coastal Act) and not located in the
area between the sea and the first public road or within 300 feet of the
inland extent of any beach (whichever is greater) (Section 13250(b)(4) of
14 Cal. Admin. Code.
The proposed development is an improvement to an existing single family
--residence and is located in the area between the sea and the first public
road or within 300 feet of the inland extent of any beach (whichever is
greater) but is not a) an increase of 10% or more of internal floor area,
b) an increase in height over 10%, or c) a significant non-attached
structure (Sections 30610(a) of Coastal Act and Section 13250(b)(4) of
Administrative Regulations).
(OVER)
Page 2
The proposed development is an interior modification to an existing use
--with no change in the density or intensity of use (Section 30106 of
Coastal Act).
__ The proposed development involves the installation, testing and placement
in service of a necessary utility connecti-on between an existing service
facility and development approved in accordance with coastal development
permit requirements, pursuant to Coastal Act Section 30610(f).
__ The proposed development is an improvement to a structure other than a
single family residence or public works facility and is not subject to a
permit requirement (Section 13253 of Administrative Regulations).
__ The proposed development is the rebuilding of a structure, other than a
public works facility, destroyed by natural disaster. The replacement
conforms to all of the requirements of Coastal Act Section 30610(9).
Other:
Please be advised that only the project described above is exempt from the
permit requirements of the Coastal Act. Any change in the project may cause
it to lose its exempt status. This certification is based on information
provided by the recipient of this letter. If, at a later date, this
information is found to be incorrect or incomplete, this letter will become
invalid, and any development occurring at that time must cease until a coastal
development permit is obtained.
Truly yours,
By:
Title: Pl~
6630A