Loading...
HomeMy WebLinkAbout1530 JEANNE PL; ; CB150780; Permit. •-•-----~"·•---••.--~•-------. ' City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 04-09-2015 Residential Permit Permit No: CB150780 Building Inspection Request Line (760) 602-2725 Job Address: 1530 JEANNE PL CBAD Permit Type: Parcel No: Valuation: RESDNTL 2071302100 $31,000.00 Sub Type: RAD Lot#: 0 Constuction Type: 5B Reference #: Status: ISSUED Applied: 03/13/2015 Entered By: LSM Occupancy Group: # Dwelling Units: 0 0 Structure Type: Plan Approved: 04/09/2015 Issued: 04/09/2015 Bedrooms: Bathrooms: 0 Orig PC#: Inspect Area: Plan Check #: Project Title: BYRNE RES=REMODEL KITCHEN/ LIV ROOM.GUEST BDRM APPROX 192 SF, REMOVE EXISTING FIREPLACE IN KITCHEN AREA/ RECONFIGURE SOME CLOSET AREAS FOR NEW PANTRY AND CLOTHES CLOSET/ REPLACE BAY WINDOW W/AWNING TYPE//ADD 12 'DOOR SYSTEM @BACK DOOR Applicant: DUNN CARPENTRY 4219 BEACH BLUFF RD CARSLBAD CA 92008 760-497-8200 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee $284.65 $0.00 $199.25 $0.00 $0.00 $4.03 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $2.00 $0.00 Owner: BYRNE GERI M 2600 W HOWE ST SEATTLE WA 98199 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnLieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES Total Fees: $640.85 Total Payments to Date: $640.85 Balance Due: Inspector: FINAL.A~PRO~ Al-) Date: -I '2--' f · Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $40.00 $45.00 $65.92 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $640.85 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any · I i n N T E imil r hi r as I w i h h 'mi i n h vi sl therwi THE FOLLOWING APPROVALS REQUIRED PRl<ffl TO PERMHIJSSUANCE: □ PLANNIIIIG □ ENGINl£ERING a C City of Building Permit Application Plan Check No. fl P-./'::,"'TJ, ID 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value Sl,O00 Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov Date Q../12 / r ~ www.carlsbadca.gov SWPPP JOB ADDRESS 1530 Jeanne Pl. Carlsbad, 92008 SUITEf/SPACEt/UNR"f I'"" 207 -130 -21 -00 CT/PROJECT# llOT# lPHASE # T#OFU1NITS l#BEDR~MS # BATHROOMS I TENANT BUSINESS NAME I CON;;;E I occ. GROUP 2 Byrne DESCRIPTION OF WORK: Include Square FNt of Aff'ectlld Atu(sJ Remodel kitchen, living room, guest bedroom (Approx 190 sq ft). Remove existing fireplace. Add 12' door system to back yard. Install new HVAC unit in attic space. Reconfigure some closet areas to accommodate new pantry & overflow clothes closet. Replace bay window in kitchen with awning type. EXJSTINO USE IPROPOSEDUSE !GARAGE (SF) PA7!//J 1°N/A FIREPLACE 1 IAIR CONDITIONING I I FIRE SPRINKLERS residential living residential living 4-5 'f YES0, Nol2] YESt;Z]No □ YES□Noi;zJ APPLICANT NAME Ron Dunn PROPERlY OWNER NAME Geri Byrne ADDRESS ADDRESS 4219 Beach Bluff Rd. 1530 Jeanne Place CITY STATE ZIP CITY STATE ZIP Carsbad Ca 92008 Carlsbad Ca 92008 PHONE I FAX PHONE I FAX 760-497-8200 206-679-3891 EMAIL EMAIL rondunn66@.me.com Geribyrne3@.gmail.com DESIGN PROFESSIONAL MA Drafting Services CONTRACTOR BUS. NAME Dunn Caroentrv ADDRESS ADDRESS 432 Ed11ehill Lane #135 4219 Beach Bluff Rd. CITY STATE ZIP CITY STATE ZIP Oceanside Ca 92054 Carlsbad Ca 92008 PHONE I FAX PHONE I FAX 760-908-6928 760-497-8200 EMAIL EMAIL misael441@.gmail.com rondunn66@.me.com I STATE UC.# STA.TE LIC.# !CLASS B I CllY BUS. LIC.1240057 1000163 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its issuan~.iJso r~uires the appllcant for such permit to fife a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law )Chapter 9, commending with Section 7vvu of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). WORKERS' COMPENSATION Worbra' Compensation Declaration: / hereby afflrm under penalty of pBljury Oll8 of the following declarations: D I have and will maintain a certlllcata of consent to self-Insure forworllers' compensation as provided by Section 3700 of the Labor Code, for the perfonnance oflhe work for which this permit is issued. llJ I have and wlll maintain workers' compensation, as reauired bv Section 3700 of the Labor Code, for the performance of the work for which this P81Tllit is issued. My workers' compensation insurance carrier and policy o,mberare,lns,ranceCo State Fund Po;cyNo. 9125068-15 E,q,i--~110,~u,u Jm.section need not be completed if the pennlt Is for one hundred dollars ($100) or less. z/18/"'Z..OI (o U Certificate of Exemption: I certify that in the perfonnance of the work. for which lhis pennit is issued, l shall not employ any person in any manner so as to become suti;ect to the Workers' Compensation Laws of Califomia. WARNING: Fallurv kl securv wol"tl:ers' ijsatlon coverage Is unlawful, and shall subject an amployerto crimlnal penalties and dvll fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, da n for In Section 370fl of the Labor code, Interest and attorney's feel. ,If CONTRACTORSIGNAll/RE □AGENT DATE Mir/LC.II IZ. -Z.Ol"'i I hereby afflrm that I am exempt m>l11 Contractor's License Law for the following mason: 0 I, as owner of the property or my employees with wages as their sole oompensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Cootractor's License Law does not apply to an owner of property who buHds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold Mthin one year of completion, the owner-builderwiR have the burden of proffiJ that he did not build or improve for the purpose of sale). □ □ I, as own8' of the property, am exdusively contracting with licensed contractors lo conslruct the project {Sec. 7044, Business and Professions Code: The Conlractor's License Law does not apply lo an owner of property who bulk!s or improves thereon, and contracts for such projects with contractor(s) licensed pu,suant lo Iha Contractor's License Law). I am exempt under Section ____ Business and Professions Code for this reason: 1. I personally plan to provide the ma;or labor and materials for construction of the proposed property improvemenl [Jves Oo 2. I (have/ have not) signed an application for a building pennit for the proposed work. 3. I have conlracled with the folloYAng person (!inn) lo provide the proposed construction (include name address/ phone I contractors' license number): 4. I plan lo provide portions of the work, but I have hired the foHowirg person to coordinate, supervise and provide the major work (include name/ address I phone/ conlraclors' license number): 5. I will provide some of the work, but I have contracted (hired) the foll!1Ning persons to provide the work Indicated (include name I address/ phone/ type of work): If PROOERTY OWNER SIGNATURE □AGENT DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMIT$ ONLY Is lhe applicant or future building occupant required to submit a business plan, acutely hazardous materials regislration form or risk management and prevention program under Sections 25505, 25533 or 25534 of lhe Presley-Tanner Hazardous Substance Accoont Act? □ Yes □ No Is the appUcanl or future building occupant required to obtain a permit from the air pollution control district or air qualify management district? □ Yes □ No Is the facility to be constructed within 1,CMXl feet of the outer boondary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE Of EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I oerttrylhat I haw read the appllcaUon and state that the above Information Is coned and that the information on the plans is acct1rate. t agree to oomply'Mth all Cltyordlnancesand State laws 181atil'Cto bulldillf construction. I hereby aulhorize ~ of Ille Ci!/ of Ca!lsbad lo enter upon above rronloned property~ i,spedion purposes. I Al.SO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS TIE CfTY OF CARLSBAD AGAINST ALL LIABLmES, Jl.lOGMENTS, COSTS AND H MAY IN ANYWAY ACCRUE AGAINST SAID CllY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: Ari OSHA permit is requi'ed foc excavations over 5' ilkln or <Xll'lSlruction fl slruclures over 3 sbries in heighl EXPIRATION: Every permit issued by the Buik:ling · of this Code shal expi'e by rmilalion and becone nufl clld vcid l lhe buildi'lg or work authorized by perrril is not commenced witlin 180da)$fi"oollhedaleofsud'lperrrila-ifflebuiklin sud'lpermitissuspendedorabandonedatan · • • ot1 ys(Secoon 106.4.4UnifoonBuikmgCode). ,.S APPLICANT'S SIGNATUR DATE :3 IJ ZOIS Inspection List Penni!#: CB150780 Type: RESDNTL RAD BYRNE RES=REMODEL KITCHEN/ LIV ROOM,GUEST BDRM APPROX 192 S Date _ Inspection Item Inspector Act Comments 07/23/2015 89 Final Combo RI 07/23/2015 89 Final Combo PD AP 05/04/2015 17 Interior Lath/Drywall PB AP 04/30/2015 31 Underground/Conduit-Wirin PB AP 04/30/2015 84 Rough Combo PB AP Friday, July 24, 2015 Page 1 of 1 P!OJErl': Ac c u 1T ~CH AF'F'CRDABLE INSPECTIONS 0 SIBEL ASSEMBLY/WELDING !il' EEOXY Al\Cl{)RS/rovELS 0 SHEAR WALL FPJ\MIN3 SYSIEM BUX; PER-fiT: CW-ER: AOCHI'IECT: EN3INEER: 760-846-1464 PO Box 900864 San Diego,CA 921 90 www.AccuTechSD.com JBietz@AccuTe chSD.com PIAN FIIE: SPEX::IAL INSPECTICN IXES NOI' RELIEVE THE CMINER, O)NIRl\CTffi CR BUIIIBR OF THEIR RESPCNSIBILITY TO P:ERF()R,1 APPRCNED PIANS, SPECIFICATIONS AND APPLICABIE MIDIN3 (X)[)E. FOR ANY l'-D-J-{)'.)NFDRMIN3 I'IEM3 PIEASE SCHEDUIE INSPECT'ICN. ALL IDRK EERFffiMED IS BILIED IN 4 !DUR INCREMENI'S ACXORDIN3 'ID CUR CURREN!' RATE SGJECULE. I .AGREE 'ID INID1NIFY AND IDLD ~S THE INSPEX::'Iffi AND ACX:.U'Ill:H AFFORDP.BIE INSPECTICNS FOR ANY AND ALL D~ffiS WHETHER AO:II»JTI\L OR INTENTIONAL. I WILL PNI FOR ANY AND ALL ATIOFNEY AND CXXJRr OOSTS. I WILL PAY FOR ANY AND ALL JULGM:NTS Bro.JOO' AGAINST THE INSPEC'IDR AND/OR ACX:UIECH AFFORDABLE INSPECT'ICNS DUE 'IO ANYTHIN3 RELA'IED TO THIS PROJECT . INSPECT'ffi: CW-ER: m'IE: SIGJA'IURE: .IS CXNI'RAC'Iffi: ffi'IE : 1 _;.7 -/S. EsGil Corporation In !Partnersnip witn (jovemmentfor<Buifaing Safety DATE: 04/08/2015 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-0780 PROJECT ADDRESS: 1530 Jeanne Place PROJECT NAME: Byrne Alteration SET: III •M•-•••s••• •••,>• • ••••"•------ □ APPLICANT □ JURIS. □ PLAN REVIEWER □ FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Ron Dunn ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Ron Dunn Telephone#: 760-497-8200 Date contacted: (by: ) Email: rondunn66@me.com Mail Telephone Fax In Person 0 REMARKS: By: Aaron Goodman EsGil Corporation □ GA □ EJ □ MB □ PC Enclosures: 04/06/2015 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 EsGil Corporation In <Partnersfiip witfi !jo1Jernment for (}Jui(ain9 Safety DATE: 04/01/2015 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-0780 PROJECT ADDRESS: 1530 Jeanne Place PROJECT NAME: Byrne Alteration SET II LICANT IS. N REVIEWER □ FILE 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Ron Dunn 0 EsGil Corporation staff did not advise the applicant that the plan check has been completed. ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Ron Dunn Telephone#: 760-497-8200 Date contacted: 't-1 (bye() Email: rondunn66@me.com .( Mail X Telephone X Fax In Person 0 REMARKS: By: Aaron Goodman EsGil Corporation □ GA □ EJ □ MB □ PC Enclosures: 03/30/2015 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 . . . NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 5. Sheets A2.0, A3.0 and A4.0 key notes, call-outs and details appear to be incorrect. Please correct. Please correct the call-out for the "4 panel Slider window" to "A" instead of "B". 6. Correct the energy forms as necessary. Your response, "Not Needed." Please see the California Energy Code Section 150.2(b)1B. CEnergyC 150.2(b)B. Replacement fenestration. Replacement of fenestration, where existing fenestration area in an existing wall or roof is replaced with a new manufactured fenestration product and up to the total fenestration area removed in the existing wall or roof, the replaced fenestration shall meet the U-factor and solar heat gain coefficient requirements of Sections 150.1 (c )3A and 150.1 (c)4. Exception 1 to Section I50.2(b)1 B: Replacement of vertical fenestration no greater than 75 square feet with a U-factor no greater than 0.40 in Climate Zones 1-16. You will need to call out the U-factor and SHGC for all new windows on the plans. 9. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Aaron Goodman at EsGil Corporation. Thank you. • EsGil Corporation In IPartnersnip witn qovernment for <Bui[,fing Safety DATE: 03/20/2015 JURISDICTION: City of Calsbad PLAN CHECK NO.: 15-0780 PROJECT ADDRESS: 1530 Jeanne Place PROJECT NAME: Byrne Alteration SET:I ~PPLICANT _.)'I JURIS. □ PLAN REVIEWER □ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IZJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZJ The applicant's copy of the check list has been sent to: Ron Dunn D EsGil Corporation staff did not advise the applicant that the plan check has been completed. IZJ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Ron Dunn Telephone#: 760-497-8200 /~Date cont;icted:.5 /7-{J (by: '{i1+ Email: rondunn66@me.com -'5-Mail ~~hon:"'} Fax In Person 0 REMARK. 0'- By: Aaron Goodman EsGil Corporation 0 GA O EJ O MB O PC Enclosures: 03/17/2015 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 15-0780 JURISDICTION: City of Calsbad PROJECT ADDRESS: 1530 Jeanne Place FLOOR AREA: No new added REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 03/20/2015 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 03/17/2015 PLAN REVIEWER: Aaron Goodman This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. There are several penned in changes on the plans as well as errors in references. Please correct all. Please, no penned in changes. 4. Show that the new bedroom has an egress window meeting the following requirements. Sleeping rooms shall have a window or exterior door for emergency escape. Section R310. a) Windows must have an openable area of at least 5.7 square feet, with the minimum openable width 20" and the minimum openable height 24". b) The bottom of the clear opening shall not exceed 44" above the floor. Do not measure to the window sill. This generally applies to windows that have a height of 3' or less. See the figure below to see the correct method of measurement. c) Such openings shall open directly into a public way or a court that opens to a public way (4-sided courts are prohibited). d) If such openings occur at a patio, the patio may not be enclosed. Appendix H, Section AH105.1. e) The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of any keys or tools. f) For egress openings at window wells, refer to Section R310.2 for requirements. 5. Sheets A2.0, A3.0 and A4.0 key notes, call-outs and details appear to be incorrect. Please correct. 6. Correct the energy forms as necessary. 7. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.8(A): Family, living, bedrooms, dining, halls, etc. d) GFCI protected outlets for locations described in NEC 210.8: Kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. 8. Show on the plans that countertop receptacle outlets comply with CEC Article 210.52(C): In kitchens a receptacle outlet shall be installed at each counter space 12 inches or wider; Receptacles shall be installed so that no point along the wall line is more than 24 inches; Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle. (Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces). 9. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 10. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Aaron Goodman at EsGil Corporation. Thank you. . ' [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Calsbad PREPARED BY: Aaron Goodman BUILDING ADDRESS: 1530 Jeanne Place BUILDING OCCUPANCY: R-3 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Alteration Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance _, Bldg. Permit Fee by Ordinance laJ Plan Check Fee by Ordinance _ll!lll Type of Review: 0 Complete Review D Repetitive Fee Ffti Repeats Comments: D Other D Hourly EsGII Fee PLAN CHECK NO.: 15-0780 DATE: 03/20/2015 Set I Reg. VALUE ($) Mod. 31,000 31,000 $284.89! $185.181 D Structural Only f-------ll Hr. @ • $159.541 Sheet 1 of 1 macvalue.doc + • ·, '~ ~-... ~ CITY OF CARLSBAD PLAN CHECK REVIEW TRANS MITT AL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE:03/18/2015 PROJECT NAME: BYRNE FAMILY REMODEL PROJECT ID: CB150780 APN: 207-130-21-00 PLAN CHECK NO: 1 VALUATION: $31,000 SET#: 1 ADDRESS: 1530 JEANNE PL ✓ This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: VALRAY NELSON A Final Inspection by the ENGINEERING Division is required Yes ✓ No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: RONDUNN66@ME.COM You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING . ' FIRE PREVENTION 760-602-4610 760-602,2.7'!10 760-602-4665 . Chris Sexton Kathleen Lawrence Greg Ryan 760-602-4624 760-602-2741 760-602-4663 Chris.SextQn@carlsbadca.gov Kathleen.Lawrence@carlsbad~~.gov Gr~gory.Ryanlg/~§rl~badca.gov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@cgrlsbadca.gov Linda.Ontivero~@carlsbadca.gQv Cynthla.Wong@carl~badca.gov ✓ ValRay Marshall Dominic Fieri 760-602-2773 760-602-4664 Va1Ray.Marshall@carlsbadca.gov Dominic.Fieri@cgrlsbadca.gQv Remarks: ALL INTERIOR WORK EXCEPT FOR ADDITION OF THE FIREPLACE. /4'~ ,, '• ·~ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for C8150780 Date: 03/18/2015 Project Address: 1530 JEANNE PL APN: 207-130-21-00 ProJ·ect Descr·ipt·ion·. REMODEL KITCHEN, LIVING ROOM, GUEST ROOM, ADD HVAC SYSTEM AND RECONFIGURE CLOSET Valuation: $31,000 SPACE. ENGINEERING Contact: VALRAY NELSON Phone 760-602-2773 Email: VALRAY.MARSHALL@CARLSBADCA.GOV Fax 760-602-1052 RESIDENTIAL INTERIOR ✓ RESIDENTIAL ADDITION MINOR (<$20,000.00) CARLSBAD PREMIER OUTLETS OTHER: GYM TENANT IMPROVEMENT PLAZA CAMINO REAL COMPLETE OFFICE BUILDING r··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··1 OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: VALRAY NELSON DATE: 03/18/2015 REMARKS: ALL INTERIOR MINUS THE FIREPLACE ADDITION Notification of Engineering APPROVAL has been sent to RONDUNN66@ME.COM via VALRAY.MARSHALL@CARLSBADCA.GOV on 03/18/2015 -··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-· E-36 Page 1 of 1 REV 4/30/11 Fee Calculation Worksheet ENGINEERING DIVISION Prepared by: Date: 03/18/2015 GEO DATA: LFMZ: I B&T: Bldg. Permit#: CB150780 Address: 1530 JEANNE PL Fees Update by: Date: 03/1812015 Fees Update by: Date: 03118120)i EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft.JU nits Types of Use: Sq.Ft.JU nits Types of Use: Sq.Ft.JU nits Types of Use: Sq.Ft./Units ADT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units Types of Use: Types of Use: Types of Use: FEES REQUIRED: Sq.Ft./Units Sq.Ft./Units Sq.Ft./Units EDU's: EDU's: EDU's: EDU's: ADT's: ADT's: ADT's: ADT's: Within CFO: YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) NO 1. PARK-IN-LIEU FEE: NW QUADRANT ✓ NE QUADRANT SE QUADARANT SW QUADRANT ADT'S/UNITS: I X FEEIADT: I =$ □ 2.TRAFFIC IMPACT FEE: ADT'SIUNITS: I X FEEIADT: I=$ □ 3. BRIDGE & THOROUGHFARE FEE: DIST. #1 DIST.#2 DIST.#3 ADT'SIUNITS: FEEIADT: 1=$ □ 4. FACILITIES MANAGEMENT FEE ZONE: ADT'S/UNITS: 1x FEE/SQ.FT.IUNIT: I=$ □ 5. SEWER FEE EDU's 1x FEE/EDU: I =s □ BENEFIT AREA: EDU's 1x FEE/EDU: I=$ □ 6. DRAINAGE FEES: ALL o PLDA: HIGH MEDIUM LOW ACRES: 1x FEE/AC: I=$ □ 7. POTABLE WATER FEES: UNITS CODE CONN. FEE METER FEE SDCWA FEE TOTAL «~/' ~ CITY Of CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 3/16/15 PROJECT NAME: REMODEL PROJECT ID: Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.eov PLAN CHECK NO: CB150780 SET#: ADDRESS: 1530 JEANNE PL APN: i,~~~s~~~~ check review is complete and has been APPROVED by the PLANNING By: GINA RUIZ A Final Inspection by the PLANNING Division is required □ Yes ~ No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: RONDUNN66@ME.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 □ Chris Sexton □ Chris Glassen □ Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.S~xt2n@tarl~!;2ad~a.g2v Christogher.Glassen@carlsbadca,.gvv G ff:?i{Q .!'.Y. Ry_a n@ca rl s ba 0<::.a ._g_Q v, □ Gina Ruiz □ ValRay Marshall □ Cindy Wong 760-602-4675 760-602-27 41 760-602-4662 Ging.Ryiz@c;_grlsbMCg.gQV Yal Ray. Marsh a ll@c~rlsbadca.gov Qyn!hia.Wong@carlsbag_c;_q.gov □ □ Linda Ontiveros □ Dominic Fieri 760-602-2773 760-602-4664 Li nd a . On.ti ve ros@ca r Is bq d c;a: ,.gQ~ Dominic. Fi eri(fycsi.rlsbadca.gov Remarks: -··----------- «,'1'> ~ CITY OF PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Building@carlsbadca.gov CARLSBAD B-18 Project Address: Permit No.: lnfonnatlon provided below refers to wom being done on the above mentioned permit only. This form must be completed and returned to the Building Division before the permit can be issued. B-18 Building Dept. Fax, (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains.................................................... ~ New building sewer line? ......................................................................................... Yes __ No X Number of new roof drains? ............................................................................................................. _:1it::._ Install/alter water line?........................................................................................................................ _gi.- Number of new water heaters?......................................................................................................... .:B-- Number of new, relocated or replaced gas outlets? .................................................................... _J__ Number of new hose bibs?.................................................................................................................. ..e-- Residential Permits, / New/expanded service: Number of new amps: __ N_,_I~ 1A-__ _ 7 Minor Remodel only: Yes__,)(_ No Commerclal/lndustrlali Tenant Improvement: Number of existing amps involved in this pro/ect: Number of new amps involved in this proiecf; New Construction, Amps per Panel: Single Phase ............................................................... Number of new amperes ______ _ Three Phase ................................................................ Number of new amperes ______ _ Three Phase 480 ....................................................... Number of new amperes ______ _ Number of new furnaces, A/C, or heat pumps? ....................................................................... _J__ New or relocated duct worb? ....................................•......•............................ Yes X No __ _ Number of new fireplaces?................................................................................................................ ,&- Number of new exhaust fans?........................................................................................................... -0- Relocate/install vent?........................................................................................................................ ~ Number of new exhaust hoods? .................................................................................................. _j__ Number of new boilers or compressors? ........................ ::£2::: ....................... Number of HP -&-- Page 1 of 1 Rev. 03/09 CB150780 1530 JEANNE PL BYRNE RES=REMODEL KITCHEN/ ~I_V ROOM.GUEST BDRM APPROX 192 SF RFMOVI= clflj 4/~ I"> (c..,TI -tJ lf.q.1~- Final Inspection required by. □ Plan □ CM&I □ Fire SW □ISSUED Anproved Date BUJlDING ,f/'fl'll~ Pl.ANNING .!!./Jr,/,~ ENGINEER/NG 31,lrf ,s- FIRE Expedite? y N DIGITAL FILES "-uired7 y N HazMat APCD Health Forms/Fees Sent Rec'd Encin.i Fire HazHealthAPCD PE&M .:ll/3Jt:::. School Sewer Stormwater Special Inspection CFO; y N LandUse: Density: lmpArea: FY Anne~ PFF: y N Comments Date Date Dao Building 3/;;oj,;, ., 7,/,' Planning I Engineering Fire Need?