HomeMy WebLinkAbout1555 FARADAY AVE; 100 | 200; PC070016; Permit02-15-2008 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: Applicant: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Permit No: PC070016 Building Inspection Request Line (760) 602-2725 1555 FARADAY AV CBAD PLANCK 2121303000 $0.00 . Lot#: Construction Type: SPEC SUITES-CREATE 2 SUITES 0 23162 SF SHELL TO OFFICE BUILDING TOTAL 25431SF Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: PENDING 02/14/2007 LSM RICHARD CORNELIUS STE 250 BLACKMORE SIGNAL HILL 3515 HANCOCK ST SAN DIEGO 92110 619 224 3605 Plan Check Fee Additional Fees Total Fees: Inspector: $0.00 PO BOX424 RANCHO SANTA FE CA 92067 Total Payments To Date: FINAL APPROVAL Date: $0.00 Balance Due: $0.00 $0.00 $0.00 ByiLDING PLANS ~fNSTO~ -ATTACHED OCA.n(\~ Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as '1ees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has nreviouslv otherwise exnired. .. FOR OFFICE USE ONLY G.,F-0 ~ ~cu;e:.e.c::, ~ PLAN CHECK No. PCo7 ..-l 0 ttn & t"\-e.:w... c..& Cii. ct -t> s a, PERMIT APPLICAl'fON /, EST. VAL. __________ _ Cf> O 7c)4{.,1 -;;;2. /c...&)-fQ4{pS' Plan Ck. Deposit_,_~--~_,_ ___ _ CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Validated By ___ ~-~------ Date _~~-=+(-t '::f_,_f_t()'-J~-- ---------------7 ----_____ j JbO 1.00 Address (include Bldg/Suite # Business Name (at this address) MAf' 12815 Legal Description 1o. '.2-IQ.-l?JO-;x:J 105 ~r No. 55--M: 5 Total# of units Assessor's Parcel # Phase No. OfflGE. Lot No. Subdivision Name/Number Unit No. v~~itc?ff\U::: Jtttl.v Proposed Use oms # of Bathrooms ( ~ame Address City State/Zip Telephone# Fax# t3. · APPLICANT D Cdntractor D :Agent-forContra_ctor . D Owner -· · :jJ _ _hg~ntfor-Owner --__ · _____ --= ::_::_::_:_·_·-:-·J ~~~J20 GO@Ne.t..lo,Ad;;!? t'A\\..Ya:.Jl.. f:Jf.';c~,:re. 2i5qot~,gli:Cf);04Ji;~~~# bJc;i-.2.2.4 ---~005 14. PROPERTY OWNER. -------------------...c ---~--:--~:=:7 1~1:>l ~ ~ WAJ?e:2 FAAADAY-\'(iye') x,1-re. \a;tt2.1,,:,PJID{e~ol!;c:xP? 7W-804 ::5000 /5. · CONT~CTOR -COMP~N;'( NAME -~----~-__ ,J (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to constru9t, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of th~ Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subje!,cts the applicant to a civil penalty of not more than five hundred dollars [$5001). fl.fE.I\JO CoN:n24c..---nJJG( I NC.c 145.? E2AZS£. 12.D ,~ la? $J\J PfECJo C:A8aa3 (<e,tc:\) 220::02.2.4- Name Address ' City 7 State/.Zip Telephone # State License# 0]4Q0C} License Class B City Business License# l '.2.C()025 @IC.JtA@.DyeN ;t. A"Z'fr~-Y5fO ~Nr.a-J::...~ ,S:21re.t';'V ~AN P1e(JO cA qz_rto Col0\-224.¾C?'S Designer Name Address ~ "' City f State/Zip 7 Telephone # State License# G-11 t'.2'q:,3 ' • /6. WORKER'S:COMPENSAtlON · ==~~-,=-:~~] Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued • if' I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: or AMe:.(2.lc.A-~= I_ J Insurance Company ~~"FIAA t ~T"( CO. Policy No. Cl ,06~'.?>19 Expiration Date_~OI O"-].._ __ _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars($100,000), in additlon to the cost of compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorney's fees. SIGNATURE DATE. _______ _;-_-_-_-_ [!:: OWNER:BUILDER1DECLARATlON _____________________ _ ---1 ---·----· __ j I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). a, I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES 0 NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name/ address/ phone number/ contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ /ontractors license number): ------------------------------------------- 5. I will provide some of the wor , ersons to provide the work indicated (include name/ address/ phone number/ type of work): . ., ~ I "PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT ; 1635 Faraday Ave., Carlsbad CA 92008 ·' Page 2 of 2 • , I ;~~Pj;~~~@W~~~~~!Bf'..~T/Af-!~l!mR!NG.!RE~~~~=s~--'.3:.i.,{.~,r:f.I~i,s{T~~§;:£2!':µJ , Is the' applicant-or future buildll'.lg occupant required to sllbrhit a business plan, acutely hazardous materials registration for onisk managemeRI and prevention prograrjl uhaer · Sections 25505, 25533 or 25534 of _the Presley-Tanner Hazardous Substanc,e Accou_nt Apt? p ,YE~ .. _ NO , , Is !lie applicant or future building occupant required-to obtain ~-permiffrom the ~Ir-pollution control district or air quality nianagement district? D YES ti NO Is the facility to be constructed within ~ ;0pMljlet;ofithe outer boundary of a s~h-90l,si\e? El1 Y~S ·.II !)JO~ ;, , ; • '. IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY, MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIR!=MENTS OF THE OFFICE OF EMl;R~~!'\ICY SERVICES A,ND1THE'AIR:i>OLl:.UTION CONTROi,. QIST~ICT: ' • 'I I ;, ; ; ... , • ' · (a .. :~ tc.o~~!,RQ9~l9Ni~E;NDIN9r,\~NC.:YC·' >~z:-: ;~t-'. }~~~\Lr\, -'·~,.;,~~·-~ -~ ;: , :_:,. ,;., ., · , ., , ;;,.' .. ::·~ ;-' · ;;.: ::~: · · ;, · ',, ·,, ·,':( ' ;l~ _. : : :0.J ! I hereby affirm ttiat tliere is.a co~st~uct(on-jendinq.ag11ncy fot the:perforrilance.of thew~rk:for whi9h this permit is·issued (~ec. 3097(1) Civil Code). , . LENDER'S N{\ME _____________ -'---'----'---'--t.ENDER'.SAQDRESS ___________________ _ [9,::: -~PRlliCANT{C1;~~~7;'.'. ''.:.:: ,, t :-·: • ,:;\;:;l;"';;,;; i,,,/~ IS>} ,; , ,: ;,_" ,; , : .,., •', , , '.:,;;.·,' ·,··fi:':'.;. · (~~"-.:: ",.., ,';'<S?Ft7W~3 _ I certify-that I have -read the· application-and state that the above information is correct and tliat the information on the plani; is accurate. I agree to comply with all City '. ordinances and State laws relating.to building construction. lihereby·authorize representatives of the .City of Carlsbad to enter upon the above mentioned. property for inspection · purpose~:. 1 'AL!so· AGREE TO :sAve, INDEMNIF:V AND1 KE~P:HARML:Ei;s .JHE-CITY ,OF ,CARL:SB:AD AGAINST•,Al.:L. 1::IABILITIESrJUDGEMENTS,! ·co'sts AND :EXPENSES WHICH·MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE ~RANTING OF THIS PERMIT. OSHA: An O$HA permilis required for exc'lvations of 5'0" _deep and c[emolitipn or consirucllon qf ~tructures oyer _3 sforiei, in height. _ . . . _ , _ :·. : .... .,. J ,_ .. ,\ l "':~ 1/¥'~-.. ,/' ~ • .,f11 J_ 'l .. "•t ,~-(.-..-""'l:,t/\_j,'\:l ' ·, •. -1: ~-:,._,,.._._' l ... "";-• 'EXPIRATION: Every permifjssued by the building Official unde(tlie provisions of this CoJ;le shall,expire,by limitation and become null and void if the building or work authorized by such permit' ls-not commenced within 180 days frc;>m the:date of sµch.permit or if the puilding or work authorized-by such permit Is suspended or abandoned at any time after ·t,he work 'is commenced.for a pe -180 days ection 06.4.4-Uniform Buliding Code). { 1-\PPLICANT'S SIGNATURE _L _ _..:!::.:::__::::::f~===·=:::::::::::::::::_ _____ .-, _--~ DATE __ -----'~--l,f--~"--f,_,.O'-fl---------'--- .... : I,_ f -1 •• j .. ',. I-'~ \ ,.,_~-::rj. .. '"J~·: .. "'-\..-"!. i q-; • 1 !j I • . i ,,. .. ,/ \, : ,-· j ; J-L, ;~ :~ J ... I jl' I .i j' \ ', I I:.'\ .. • . '- .- \~ /.-_ EsGil Corporation In a!artnersli.ip witli. (}overnment for <:Bui(aing Safety DATE: 4/26/07 JURISDICTION: City of Carlsbad PLAN CHECK NO.: PC07-16 PROJECT ADDRESS: 1555 Faraday Ave SET:IV PROJECT NAME: The Blackmore Co. Spec Suite -TI , ~{LICANT ~IS. CJ PLAN REVIEWER CJ FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person D REMARKS: By: Doug Moody Enclosures: Esgil Corporation D GA D MB D EJ D PC 4/19/07 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ... EsGil Corporation In (Partnership witli. government for (]3ui{aing Safety DATE: 4/18/07 JURISDICTION: City of Carlsbad PLAN CHECK NO.: PC07-16 ' PROJECT ADDRESS: 1555 Faraday Ave SET: III PROJECT NAME: The Blackmore Co. Spec Suite -TI D APP~NT @JUR D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted 'herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [ZI The applicant's copy of the check list has been sent to: Richard Yen and Associates / Richard Cornelius 3515 Hancock St. Suite 250, San Diego, CA 9211 0 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [ZI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contact~11' ~!Jhard Cornelius Telephone#: 619-224-3605 Date contacted~ /rf01<i»J/.-/f3) Fax #: 619-224-1530 Mail Telephone D REMARKS: Fav In Person By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 4/11/07 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ,_-Cit,y of Carlsbad PC07-16 4/18/07 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 1555 Faraday Ave DATE PLAN RECEIVED BY ESGIL CORPORATION: 4/11/07 REVIEWED BY: Doug Moody FOREWORD (PLEASE READ): PLAN CHECK NO.: PC07-16 SET: III DATE RECHECK COMPLETED: 4/18/07 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit prints to: new complete sets of B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo ,_. Cicy of Carlsbad PC07-16 4/18/07 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold underlined print indicates the unresolved issue. 9. Provide complete plumbing plans, including: a) Provide complete water line sizing plans consistent with the calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. UPC Section 610.0 No information provided. b) Show water heater size, type and location on plans. UPC, Section 501.0 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. " EsGil Corporation In (J!artnersli.ip witli. government for (}3ui[aing Safety DATE: 3/23/07 D APPLICANT ~URIS. JURISDICTION: City of Carlsbad PLAN CHECK NO.: PC07-16 SET: II D PLAN REVIEWER D FILE PROJECT ADDRESS: 1555 Faraday Ave PROJECT NAME: The Blackmore Co. Spec Suite -TI D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Richard Yen and Associates / Richard Cornelius 3515 Hancock St. Suite 250, San Diego, CA 92110 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: ri~iard Cornelius Date cont~d: 'bt~r((by: )\VJ Mail .~ephone · Fax /4 Person REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Telephone#: 619-224-3605 Fax #: 619-224-1530 Enclosures: 3/16/07 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad PC07-16 3/23/07 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 1555 Faraday Ave DATE PLAN RECEIVED BY ESGIL CORPORATION: 3/16/07 REVIEWED BY: Doug Moody FOREWORD (PLEASE READ): PLAN CHECK NO.: PC07-16 SET: II DATE RECHECK COMPLETED: 3/23/07 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit prints to: new complete sets of B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? OYes ONo City of Carlsbad PC07-16 3/23/07 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 2. Exit doors (102 and 201 B) should swing in the direction of exit travel when the area served has an occupant load of 50 or more. Section 1003.3.1.5. When additional doors are provided for egress purposes, they shall conform to the width, swing and hardware provisions in Chapter 10. Section 1003.3.1.1. 4. Please revise the single line diagram to show the grounding of the new transformers to be per section 250-30 A (4) of the NEC. Please indicate which type of grounding electrode will be used and indicate the location. 9. Provide complete plumbing plans, including: a) Provide complete water line sizing plans consistent with the calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. UPC Section 610.0 No information provided. b) Show water heater size, type and location on plans. UPC, Section 501.0 The resubmitted plumbing plans did not have a sheet P-1, please provide the missing sheet. 10. Please revise the plans to show the demising wall at warehouse 123 to have R13 insulation per the mandatory measures. The resubmitted plans now do not have signatures on the MECH-1-C and the ENV-1 forms. Please have the document author and principle designer sign the imprinted documents. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. City of Carlsbad PC07-16 3/23/07 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. ., EsGil Corporation In <.Partnersliip witli qovernment for c.Bui{aing Safety DATE: 2/27 /07 JURISDICTION: City of Carlsbad PLAN CHECK NO.: PC07-16 PROJECT ADDRESS: 1555 Faraday Ave SET:I PROJECT NAME: The Blackmore Co. Spec Suite -TI D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. l:8J The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZI The applicant's copy of the check list has been sent to: Richard Yen and Associates / Richard Cornelius 3515 Hancock St. Suite 250, San Diego, CA 92110 D Esgil Corporation staff did not advise the applicant that the plan check has been completE;id. l:8J Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Richard Cornelius Telephone#: 619-224-3605 Datecontacted:.2./zi/ol(by: ~) Fax#: 619-224-1530 Mail Telephone --Fax ---1n Person D REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 2/20/07 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Garlsbad PC07-16 2/27/07 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: PC07-16 OCCUPANCY: B TYPE OF CONSTRUCTION: VN ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 2/14/07 DATE INITIAL PLAN REVIEW COMPLETED: 2/27 /07 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: Office ACTUALAREA: 22299~ STORIES: 2 HEIGHT: OCCUPANTLOAD: 222 DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/20/07 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process. please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot City of Carlsbad PC07-16 2/27/07 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Please revise the section view of all new interior partitions. Show: a) Method of attaching top plates to structure. (Please revise the spacing of the studs used for lateral bracing to 4' or provide calculations to show the 8' spacing adequate). b) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 2. Exit doors (102 and 201 B) should swing in the direction of exit travel when the area served has an occupant load of 50 or more. Section 1003.3.1.5. 3. Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". 4. Please revise the single line diagram to show the grounding of the new transformers to be per section 250-30 A (4) of the NEC. 5. Please imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. 6. Please indicate the location of the ladder access to roof mounted HVAC equipment. 7. Indicate the location on the plans of the approved fixture to receive the main condensate discharge from air conditioning units. (UMC Section 309) 8. Please revise the plumbing plans to show the required clean-out per section 707 of the UPC at the first floor janitor sink. ,, City of Carlsbad PC07-16 2/27/07 9. Provide complete plumbing plans, including: a) Provide complete water line sizing plans consistent with the calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. UPC Section 610.0 b) Show water heater size, type and location on plans. UPC, Section 501.0 10. Please revise the plans to show the demising wall at warehouse 123 to have R13 insulation per the mandatory measures. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. CITY Of CARLSBAD POLICIES AND PROCEDURE / · 1u°MsER: so-s SUBJECT: ROOF MOUNTED EQUIPMENT EFFECTIVE: 5/1 /92. SECTION: BUILDING DEPARTMENT --- SUPERSEDES: . 80-6(9/10/80} 80-6{5/01/81} PURPOSE: PROV)DE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT A.Ni\· PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS. u INTENT: POLICY: A. Maintain roof integrity. . B. Prevenfhazardous condition to firemen 1,vho must fight fire on the roof. C. Provide an installation that is 2esthetically sensitive to the building 2nd the adjoining properties: · 1. All equipment shall be concealed from vie1.;v and the design'* shall meet the . · approval of the Planning Department. · 2. All equipment shaH be specifiq!!',' designed and approved for exterior use and shall be approved by the Cir',' of Carlsbad Building Department. 3. All roof mounted equipmem shall be on a platform v1hich shall be en k-1tearal part of the roof--f!ashsd and w2terproofed. When _a screen is· 2pp:-oved, i~ shal: have as je1;v roof connections as possib!e and be structurally ad equ2ts. 4. All electrical, plumbing, mechanical duct work and related piping shali be inslds the building.and not on the roof. All conne.ctions related to equipment sha·n be made in the s:::me roof openlng on the platform or have the prior 2pp;ova! from 5. ·s. 7. the building official. Sewer vents shall be brnug~it to one main vent below the roof znd h2ve one penetration v-:here restrooms o~ other plumbing fixtures are back to back or in the genera! proximity. Air exhaust fans and other equipment shall be within the bui!ding and use the same roof opening vvhere restrooms and other equipment are back to back or ir general proximity. Existing bul!dings and equipment, remodel or replacement, shall meet the abov, regulations or shall have the prior.appr~val frqm the building official. _ . Where new equipment is ins·ta!!ed·i unused° or abar;doned equipmen't, including· all roof mo'unted piping/ eiectric·al, mechanicalr duct, ~n.d other' related . . . appurtenances ·shall be removed from roof and unosed openings p_roper!y seale -to r11aintai_n roof integrity. · · · ·4 The architect should, through de·sign, conceal the heating/AC unit and othe~ equipment ~heth?.r they are pn the roof or elsewhere. · . .· . · · initiated By: Approved 1½//{::)_ _L City of Carlsbad PC07-16 2/27/07 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody PLAN CHECK NO.: PC07-16 DATE: 2/27 /07 BUILDING ADDRESS: 1555 Faraday Ave BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Tl 22299 34.37 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance , ,.. , Plan Check Fee by Ordinance J ..... I Type of Review: 0 Complete Review D Structural Only D Repetitive Fee =8 Repeats Comments: D Other D Hourly .__ ___ __.I Hour* Esgil Plan Review Fee ($) 766,417 766,417 $2,475.431 $1,609.031 $1,386.241 Sheet 1 of 1 macvalue.doc 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: 760-602-2719 / Fax: 760-602-8558 FAX To: Doug Moody Fax: 858 560 1576 Phone: Re: D Urgent _ D Please comment Doug, City of Carlsbad Building Department From: Laura Moore Pages: 3 INCLUDING COVER SHEET Date: March 13, 2007 CC: D For Review D Please Reply I have a discrepancy with the square footage on PC07-16. The plans state 23,162 sf and your plan check states 22,299 for a·difference of 863 sf. I have to create permits· for 2 separate suites for this building and the impact fees will be determined by the square footage so I need to know which figures I should use. If you could verify the totals and separate the 1st floor and the 2nd floor for me I would appreciate it. Thank you, Laura Moore City of Carlsbad Building Dept. •.·,···· : '• ,-..o,•' • ,:,~ I' ,., .,,. ~-~ ., --: ,;-· -. ', ':., I LOT 105 -6ENERIC T.I. 4 LOBBY CORE 15$ FAf<ADAY' AVE. CARLSBAD; CALIFORNIA Cf2008 CITY OF·CARLSBAD· U.R.M,: D YES 181 NO CMPI 212 -ISO -SO 12,Cf&t S.F. 1.2,442 S.F. 25,431 S.F. OFFICE Cf1,655 S.F. (2.242 ac.) 11,808 S.F. 23,162 S.F. .25,431 S.F. e,poo s.F. (1YPE V-N) 601-011 ALL SIDES 4 SPRINKLERED (UNLIMITED AREA PER UBc. 5052) UNLIMITED S.F. > 25,431-S.F. (OK) "i=.-. CONSTRUCTION: Y-N SPRINKLERED: 181 YES . D NO ~NCY C.LASSIFIC.ATION(S): B / OFFICE USE :,,, ''' -··;OF STORIES: \J~--tfEl6HT: -~~ii'' ·, _. VARIES FRQM 32 1-0.11 TO 361-611 MAX. .It-le CODES: . ',~-, 2001 CMC, 2001 CPC, 2001 CFC, 2001 · CEC; CAC TITLE 24 APN _ _. _ _..-,.-., AA MEI •:,. ARGHIIJ;GIJJBAI.. T5 · ilT:l.E 5HEeT : : '. _,, . 6N: . . 6ENERAL NOTIS · · . . i 6At · . AC,C,ESSIBfLITt' No~>~-~ 6A2 ACCESSIBILITY NO~ 4 A5I. SITE PLAN'. . e:,XI FIRST' Fl;:.OOR EXITINei Pl · 6X2 SECOND FLOOR EXITIN6 Al.I F.IRST FLooR PLAN . Al.2 SECOND FLOOR PLAN Al.3 FIRST FLOOR REFLECTE Al.4 SECOND FLOOR REFLEC Al.5 FIRST FLOOR FINISH Pu Al.5.1 FIRST FLOOR FINISH PL Al.6 SECOND FLOOR FINISH 1 Al.6.1 SECOND FLOOR FINISH I A2.I INTERIOR ELEY ATIONS A4.I ENLAR6ED RESTROOM: A4.2 RESTROOMS INTERIOR f A4.B ELEVATOR ENLAR<SED I AS.I A5.2 A53 "A5.4 Ab.I MO.I Mo.2· MO:B M0.4 Pl P2 P3 EO.I El.I El.2 E.2.1 E.2.2 E3.I E4.I E5.I E6.I - INTERIOR aEVATIONS DETAILS DETAILS DETAILS DETAILS DOOR AND HINDOH SC. MEGHANtCAL. MECHANIC.AL NOTES, Tl' FIRST FLOOR MECHANl1 SECOND FLOOR MECH} ROOF MECHANICAL PL PLUM61N5 PLUMBING, NOTES, SC.HE 1ST FLOOR PLUMBING, 2ND FLOOR PLUMBING, ELECTRICAL SYMBOL LIST FIRST FLOOR LIGHTINC: 5EC.OND FLOOR LIGiHT FIRST FLOOR POWER I SECOND FLOOR POJl'E ROOF PLAN·-aECTRI TITLE 24 PANEL SC.HEDULE5 SIN6LE LINE DIAGiRAl"' ... ~·J:ity of Carlsbad. PC07-16 . 2/27/07 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPAREO BY: Doug Moody PLAN CHECK NO.: PC07-16 DATE: 2/27 /07 SUILDING ADDRESS: 1555 Faraday Ave BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Tl 22299 34.37 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance j ..-j Plan Check Fee by Ordinance I ,.. I Type of Review: 0 Complete Review D Structural Only D Repetitive Fee :B Repeats Comments: D Other D Hourly .__ ___ __.I Hour* Esgil Plan Review Fee ($) 766,417 766,417 $2,475.431 $1,609.031 $1,386.241 Sheet 1 of 1 macvalue.doc <· ~ •,;)--.~ '{,,'ti.'...--• - 1-~No·IJSE AUTHORITY: 1~1~tORIC,: 0 YES '·"'. !'vi LOI NO :ffiltDING. AREA f.<t:::.-·~.: ' .f:J~r FLOOR ~ND FLOOR rcrAI.. .,: . tf?OSED USE: ,:'~s SITE ARE.A: LOT 105 -GENERIC. T.I. 4 LOBBY CORE 1555 FARADAY AVE. CARLSBAD, CALIFORNIA 'f2008 CITY OF CARLSBAD U.R.M.: 0 YES 181 NO C.MPI 212 -ISO -SO 12,'f8Gf S.F. 12,442 5.F. 25,491 S.F. OFFICE Gf1,655 S.F. (2.242 ac) 11,954 S.F. 11,eoe s.F. 29,162 S.F. ~ ]ii.ow ABLE AREA ANALYSIS I,~~·,--:,-·,'~ ' .'L ,_\_.!..!~l'' ,-,,c;·,--·. ,, , ~i(~,.! '1' t~JW,iNC? AREA: ti~1t·,ALLOWABLE: .::-~-(; totAL ALLOl"U:D: _;.\: ·::: . 25,491 S.F. e,poo S.F. ("TYPE V-N) 601-011 ALL SIDES 4 SPRINKLERED (UNLIMITED AREA PER USC. 5052) UNLIMITED S.F. > 25,4Bl·S.F. (OK) ··:_BUIL-DING CODE DATA . ,·, i·~?;";~, 1 \p.ipE OF CONSTRUCTION: V-N SPRINKLERED: 181 YES · ,.: ,. 0 NO BT OFFiCE USE --2_ . ' -,c·1:;-- \j9lJILDING l-lEIGHT: VARIES FROM 921-011 TO 561-611 MAX. .~·/\, .~-~{ <··_ ,~RNING CODES: \2001-,CBC, 2001 C.MC, 2001 C.PC, 2001 CFC, 2001 CEC.; C.AC. TITLE 24! t::;~ ~~;(·' y APN 212-130-30 j : ./LEGAL DESCRIPTION .~f105 OF CARLSBAD TRACT NO. 85-24, UNIT 5 OF t~ :J ·,,. •'[ ' ~~RLSBAD RESEARCH CENTER, IN THE CITY OF SHEET' • .. ARCHlTJ;CTUBAL TS 6N 6AI 6A2 ASI GXI 6X2 Al'.I Al.2 · Al.B Al.4 Al.5 Al.5.1 Al.6 Al.6.1 A2.I A4.1 A4.2 A4.S AS.I A5.2 A5.B A5.4 A6.I MO.I Mo.2· MO.B M0.4 Pl P2 PB EO.I · El.I EL-2-~ E2.I E2.2 EB.I E4.I ES.I E6.I TliLE SHEET 6ENERAL NOTES ACCESSl61LITY NOTES ACCESSIBILITY NOTES t DETAILS .~ITE PLAN .FIRST FLOOR EXITIN6 PLAN · · SECOND FLOOR EXITIN6 PLAN . FIRST t=LOOR PLAN ~COND t=LOOR PLAN FIRST FLOOR REFLf:C,TED CEILING PLAN SECOND FLOOR REFLECTED CEILING PLAN FIRST FLOOR FINISH PLAN FIRST FLOOR FINISH PLAN SECOND FLOOR FINISH PLAN SECOND FLOOR FINISH PLAN INTERIOR ELEVATIONS ENLAR6ED RESTROOMS PLANS 4 INTERIOR ELEVATION RESTROOMS INTERIOR ELEVATIONS ELEVATOR ENLAR6ED PLANS, SECTION AND INTERIOR ELEVATIONS DETAILS DETAILS DETAILS DETAILS DOOR AND WINDOW SCHEDULE MECHANICAL MECHANICAL NOTES, TITLE 24, SCHEDULES FIRST FLOOR MECHANIC.AL PLAN SECOND FLOOR MECHANICAL PLAN ROOF MECHANIC.AL PLAN PJ..UMBING PLUMBIN6 NOTES, SCHEDULES, DETAILS 1ST FLOOR PLUMBIN6 2ND FLOOR PLUMBING ELECTRIC.Al.. SYMBOL I...IST FIRST FLOOR Ll6HTIN6 PLAN .SECOND FLOOR l,..16HTIN6 PLAN FIRST FLOOR POWER PLAN SECOND FLOOR POJAIER PLAN ROOF PLAN -ELECTRICAL TITLE 24 PANEL SCHEDULES SIN6LE LINE DIA6RAM VICINITY MAP ·~,~ARLSBAD, COUNTY OF SAN DIEcSO, STATE OF J~.ALIFORNIA, ACCORDING TO MAP No. 12815, FILED IN THE i'.~{Ot=t=IC,E OF THE COUNTY RECORDER MAY 16, l'f'fl. r---------------------- ~: . PROJECT DESCRIPTION ;;,,:;~r~ --. ,~ t:rENANi IMPROVEMENT FOR OFFICE USE. ·;:J~VEMENT TO INCLUDE: CONSTRUCTION OF FULL AND PARTIAL )~l6HT'METAL STUD PARTITIONS, CARPET, PAINT, 6YP.6D. AND t· ··½LAY-IN-CEILING. -:~W-LIGHTING AND POWER/Sl6NAL AND MECHANIC.AL WORK AS "'.:~GUIRED PER DESl6N BUILD. NOT.ES SITE PALOMAR AIRPORT PALOMA0 A 11:::n:::,r"lc:>-r ~<) .... :(. S)f ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9. RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE TOTAL OF ABOVE FEES*:$ _______ _ *NOTE: This calculation sheet is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits. ~C€ '9{tCV(t1,,64) = 227 ··AW i-2.1 .-57 ~ Arif ~ \ 7 O 2 of 2 H:\Development Services\MASTERSIFORMS -\MISCELLANEOUS -\FEE CALCULATION WORKSHEET.doc V)JAf?_l;:::tl()t )~ 9(~ (11, 3t34j ~ ':77 (mt.Dr,) Rev. 7/14/00 i I . ENGINEERING DEPARTMENT ., FSE CALCULATlON wo.RKSHEET :EDU CALCULATIONS: List types: and square f9qtages for all -uses/.%€ R.E'J~SE=" S\ ~, QE .. Cf; . . . . . ~ Cl\1--61> L~--n~S__; Type~ of Use: ~ft~ . · S_q· .. Ft./Un·its·t . · . . -EDU's: ~-CJ . ~ 'v ' < • • Type,~ oflJse; . .. . . . . . . Sq, Ft./Units: . . . . .. . · EDU's: , . . . · . . · · ·. · . .· f2:6VcR~ 51 . . ADT CALCULATIONS: .List typ~es a.nd sqµare footages. for .all uses.f~ GALC\J t..An'DN~ Types of-User. OFf\C,f? Sq. Ff./Unit~:·...,.....----..---ADT's: .... f__.7_0=------..,....,...--'- Type,s of .Use: -.,..,....-,--,,_...,.-a.,-,--Sq: Ft/Units: . . ADT's: ----'-'-- FEES REQUIRED: . . wiTHIN'CfD: ~ES (no bridge & thoroughfarel'fee i~ District #t, re~uced, Traffic ·Impact Fee) D N.O ti t. PARK-1,N-LIEU 'F!=E . , : · . : r ~ _). . -~ -~ -{. , , / , FEE/UNIT: . , ·, if2, TRAFFIC IMPACTFEE: PARKAREA&#:_· "'"--- K Nb. UNITS: ,.'. { .-'--,..---.. -,. =$_..,..,_ __ _ APT's/UNITS,.1-7() ~-:. 1F.EE/ADT:. Z..,~ -~ =$ 4-,9 '3-0 ·o 3 .. BRIDGE ANl;JTHOROUGHFAR~ FEE (DIST, ,#.1 __ · _ DIST. #2 __ DIST. #3 __) '\ ~ -, ' ' . ' ' -, ~i ADT's/UNITS: _______ ~ X FEE/ADt: . =$..,..,_ ___ _ D 4, FACILITIES MANAGEMENT FEE ZONE:--,-~--,- . / .. . . UNIT/SQ.FT.: •. ~ 5. SEWE~ FEE ... X FEE/SQ.FT./UNIT;-,,-'--'---· =$ ___ _ . . ' t EDU1s: tf;/Jt{-' x . F~ElEDU:1,C>lf-7 =$ ~22-c:). -~: ,BENEFITAREA: F' ·' . :. : · -~D.O's: f; ~}-t<. ··, . . . . --' . . . X FEE/E~U.&1Ze-=$to,~~ •. ~ D. 6. 'sEVVER'.LATERA[·,.($2',50QY -~. =$ ___ --,.- .o . 7. DRAINAGE FEES Pi,.DA . " Hl<,H /.LOW·, ' ACRE$: X FEE/AC: .. =$ o 8. PO"fABLE WATER FEES . UNITS CODE CONNECTION FEE METER FEE SDCWAFEE IRRIGATION 1 of 2 • H:\Deyelgpme~t.Services\MASTERSIFORMS ,IMl~C.E~LANEQUS ·-\FEE·,CALCULATION WORKSHE;ET.doc, . ·Rev. ,7/.1'A/OO 1< ~-' '-~ PLANNING/ENGINEERING APPROVALS PERMIT NUMBERgf F& 07--1 b ADDREss \Ss~ Ff\Rl\Dl-\f Av' RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000.00) OTHER PLANNER --------- H:/Development Serv,ces/Masters/Applications-Counter/Planning Engineering Approvals ------·---. PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING DATE ------- ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D Estimate based on unconfirmed information from applicant. D Calculation based on building plancheck plan submittal. Address:)56'5 ~A~(:\DAY A\/ , Bldg. Permit No.CS.a:;_ ~&z$° ~0 [W 2-0b) . Prepared by: _____ Date: _____ Checked by: _____ Date: fa;B ~veR56 s1~ EDU CALCULATIONS: List types and square footages for all usesl~ CALCVt..ATlt\?N<;) Types of Use: c:FF"l C,fi Sq. Ft/Units:.______ EDU's: .cf. 2-. Types of Use:_______ Sq. Ft./Units:______ EDU's: _____ _ · . ~ -f<E\rERs:E Sl.CE._ ADT CALCULATIONS: List types and square footages for all uses.~ CALcUL.ATl,ON&) Types of Use: OPE( cG Sq. Ft/Units:______ ADT's: _1_7_7 ___ _ Types of Use: ______ _ Sq. Ft/Units: _____ _ ADT's: _____ _ FEES REQUIRED: WITHIN CFO: ~no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) ONO D 1. PARK-IN-LIE\J FEE PARK AREA & #: __ _ FEE/UNIT: ___ _ /4"RAFFIC IMPACT FEE X NO. UNITS: __ =$ ___ _ ADT's/UNITS: _1_7_7 __ X FEE/ADT: 2-<?J =$ 6,t 33 D 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 __ DIST. #2 __ DIST. #3 __) ADT's/UNITS: ___ _ X FEE/ADT: __ _ D 4. FACILITIES MANAGEMENT FEE ZONE: __ _ / UNIT/SQ.FT.: tzf' 5. SEWER FEE EDU's: 4 2-. BENEFIT AREA: F EDU's: Jf: 2- 0 6. SEWER LATERAL ($2,500) X FEE/SQ. FT./U NIT: X F~E/EDU: (104-:7 X FEE/EDU6 72-J- =$ ___ _ =$ =$ 4-p~ 7 . L{-0 =$ t l tt-f-?Z · o/0 =$ D 7. DRAINAGE FEES PLDA __ _ HIGH ___ /LOW __ ACRES: ____ _ X FEE/AC: __ _ =$ ____ _ D 8. POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWAFEE IRRIGATION 1 of 2 H:\Development Services\MASTERSIFORMS -\MISCELLANEOUS -\FEE CALCULATION WORKSHEET.doc Rev. 7/14/00 ,., ENGi'NEERING DEPARTMENT FEE CALCULATION WORKSH'El=T D 9. RECLAIMEO WATER,FEE·S UNITS .CO~!;: ·CONNECTIONFEE . METER.FEE , . \ _,' \ . -l TOTAL OF.ABOVE.FEES•:$ ___ . _________ _ * NOTE: This calculation i:;he~t !$ r.,JOT a co111plete list of aU fees which may be due. Dedications_~nd Improvements 111ay also -be':~eq.uiredwith 13uilding Permits'. '' ! I ,,. ' I, 2of.2 1H:ID.eveloP,ment 'ServicE/slMASTERSIFDRMS -IM,ISCELLANEDUS ,\FEE CALCULA TIDN WDRKSHEET.:doc . ' . ' R·ev, 7/14/00 ~ >, >, ..c ..c * ~ &i .>J!. "U -"' 0 0 <I> <I> <I> .s= .c .c () CJ CJ r::. r::. r::. "' "" "' a: a: a: ~ D D ~DD PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. PC07-16 Address: ------'-'----15"'"'5~5-'F~a=-ra=-d=a ..... v ..... A ..... v"""e""'"nu=e"--_____ _ Planner: __ J ___ o ___ M=a=l'i.-9U~e-z ____ Phone: (760) 602-4619 APN: --'2=-1=2----1--'3"""0'""'-3""'6....._ __________________ _ Type of Project & Use: · Tl Net Project Density: DU/AC Zoning: C-M General Plan:__ Facilities Management Zone: ___ _ CFD (in/out) # ___ Date of participation:. ___ Remaining net dev acres: __ _ Circle One (For non-residential development: Type of land used created by this permit: ____________________ _, Legend: ~ Item Complete @item Incomplete -Needs your action Environmental Review Required: YES NO .JL__ TYPE __ _ DATE OF COMPLETION: _______ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES __ NO X TYPE __ _ APPROVAURESO.NO. ______ DATE _____ _ PROJECT NO. _________________ _ OTHER RELATED CASES: ____________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: _______________________ _ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES__ NO X CA Coastal Commission Authority? YES __ NO __ _ If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): __ _ Habitat Management Plan Data Entry Completed? YES __ NO X If property has Habitat Type identified in Table 11 of HMP, complrte Hf0P Permit application and assess fees in Permits Plus • , (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) lnclusionary Housing Fee required: YES NO X (Effective date of lnclusionary_ Housing Ordinance -May 21, 1993.) Data Entry Completed? YES_ NO __ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 \ ~:DO '[gj .o 0 IZIOO '~DD j .. IZI .D. D '[ZI tJ 0 rgJ. DD Site Pian: .• Provide a· fµlly· dimenskmal; site plan. draW11· to scale. Show: North arrow, property line$, easem~nts,. existi'ng_ ~11d· proposed structures, .streets, exi$ting: ·street improvements, right-of-wa:y -width; dimensional setbacks and .exi$ting, topographiq~J lineS:. (inci1;1ding all side and rear yard slopes). Provide legal d~scription of property a.nd as~essor'S parcel numoer. -Policy 44 -Nei'g'1borh9od-Architectur:at: ·besi~n'Guictel'ines 1. -Appllcability: . YES .----. NO·----'- 2. .Prdject .complies YES Zonin·g:· 1 . 'Setbacks: 'Front: . Interior Side: Street-Side: -a . .,... ~ .. Rear: Top of.slope: NO_-"-_ Bequired ____ ...,........-"-----Shown Required Shown Re.quited• ~-.Shown. ---...a.......------ . R~quired . . . Shown · Req1.,1ired. $hewn 2. Acces~mry structure setbacJ<s:. Front: Requi'red --=------.---.c,..;._ Shown --'--'------ .Interior Side: Required Shown ______ _ Stree.t Side~ Required Shown ______ _ Rear: 'Required Shown_-"----- Structure separation:· Required :Shovvn _· _____ _ 3. Lot Coverage: . Required -'----~· $flown---------'-- 4. Height: Required_. -~~--Shown-. 5. Parking: Spaces. Heq1,1ired -'--'-~------Sh<;>wn ------- (breakdown by· uses for comme~cial anq industrial-proJects re·quired) Reside·ntial Gaest Space$ .Re-quire·d .. · Shown _____ _ . , .-CQ)D O -· .,A;dditio:r:raLGor:r.iment~: .. Corredtior.i. #.~ ,d~lea:se;show.or.i sheet:1,tliie-,tetal -number of parking-spaces . provided. CorrectioA #2-.Is. there. any proposed roof.mounted equipment associated with this·.building permit? If.so, wilHhe equipmentbe screened by an .existing parapet Wall-or is 11ew screening material· required? Piea:se see. the attached handouts for examples .. ~.-r::> 0!9TO ISSUE AND ENTEHED·APPRO~AL'INTO COMPUTER ~m~'1)DATES-t0--or . • ' ' j ~ -H:\A[)fvliN\COUNTER\BldgPlnchkRevCt,klst Rev:3/06 Car.lsbad Fire Department Plan Review Requirements Category: PLANCK, Date of Report: 02-15-2007 Name: Address: Permit #: PC070016 Job Name: Job Address: SPEC SUITES-CREATE 2 SUITES 1555 FARADAY AV CBAD BLDG. DEPT COPY INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully.all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0001888 [MET] APPROVED: THIS PROJECT HAS BEEN REVIEWED. AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 02/15/2007 By: MS Action: AP \ 1 NON-RESIDENTIAL CERTIFICATE: Non-Residential Land Owner, please read this . option carefuly and be ue you throughly I.Rlderstand the options before sigring. The option you choose mil affect )'(U" payment cl the developed Special Tax assessed on yow property. This option is available only at the time cl 1he first bl:ilcing permit issuance. Property owner signature is reqLired before a bulding permit v.;tl be issued. Yow signature is confirming the accuracy of all parcel and ownership information shown. ,fJa@l'.)(w 6j11CU -Hi IHDt kJ5 11a) W qikW Name of OWner Telephone · fa~ l?Jt D . , ~ ~ r-F G../'~ ~,,, Address Project Address ' A.ig.,__ ~ ~ ~ CA v/Wlcif Carlsbad CA 9200 City State Zip Code City State Zip Code __ L_ \ '2,_ .. \'J,C,-~O •lll't Assessor's Parcel Number, or APN and Lot Number if. not yet subcivided. BLilding Permit Number As-cited byOrtina'lce No. NS-155and adopted by the City~l-of the City Qf Carlsbcul, Califorria, the City., is aulhClrized to tevy a special Tax in Cornmll'ity Facilities dimct No. 1. All non-residential property, upon the issuance-of1hefirstb.iking pemit. shall have the option to (1)-pay1he SPECIAL De\lELOPMENTTAX ONE- 111\E ar (2) assume the ANNUAL SPECIAL TAX-DEVELOPED PROPERTY for a period not to exceed twenty- five (25) years. Please indcata your choice by iritiallng the appropriate line below: OPTION (1): I elect to pay the SPECIAL DEVELOPMENT.TAX ONE-ll,..ME now. as a ane-tirrie payment Amount of One-Ttme Special Tax: $ .S 8, '--l 4 ! . Owner's Initials. ___ __ OPTION (2): I elect to pay the SPECIAL DEVELOPMENT.TAX ANNUALLY for a reriod not to exceed twenty-five~ Maicimum Amual Special Tax: $ 11, , (!;, 1 _ -0wner lritials • · I DO HEREBY CERTIFY UNDER PENALTY OF PERJURY THAT THE UNDERSIGNED IS THE PROPERTY OWNER OF THE SUBJECT PROPERTY AND THAT I UNDERSTAND AND WILL COMPLY WITH THE PROVISIONS AS STATED ABOVE. . . 1-IOLD PrintN Date The City of Carlsbad has not independently verified the information shO'M'I above. Therefore, we accept no responsibility as to the accuracy or completeness-of this information. NON-RESIDENTIAL CERTIFICATE °' -z. . 2-q 1n r ~, L{ <-l 8' fr, o... lcERTIFICATE OF COMPLIANCE (Part 1 of 2) ENV-1-CI PROJECT NAME DATE Blackmore Lot 105 2/8/2007 PROJECT ADDRESS. 1555 Faraday Ave. Carlsbad PRINCIPAL DESIGNER -ENVELOPE TELEPHONE Building Permit# DOCUMENTATION AUTHOR TELEPHONE Greater San Diego Air Conditioning Co. Inc. (619) 469-7818 Checked by/Date Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 12/08/06 19,826 Sq.Ft. BUILDING TYPE [X] NONRESIDENTIAL D HIGH RISE RESIDENTIAL D D RELOCATABLE-lndicate:O Specific Climate -list: , or D PHASE OF CONSTRUCTION [X] NEW CONSTRUCTION D ADDITION D AL TERA TION D METHOD OF ENVELOPE COMPLIANCE D COMPONENT(ENV-2-C) [Xj OVERALL ENVELOPE(ENV-3-C) D STATEMENT OF COMPLIANCE CLIMATE ZONE 7 HOTEUMOTEL GUEST ROOM All Climates UNCONDITIONED (File Affidavit) PERFORMANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building envelope requirements. The documentation preparer hereby certifies that the document is accurate and com DOCUMENTATION AUTHOR SIGNATURE T.L. Harmon The Principal Envelope Designer hereby certifies that the proposed building esign represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the envelope requirements contained in Sections 110, 116 through 118, and 140, 142, 143 or 149 of Title 24, Part 6. Please check one: ~ereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the state of California as a civil engineer or mechanical engineer, or I am a licensed architect. D I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537 .2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. D I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. II Indicate location on plans of Note Block for Mandatory Measures ~------------------~ ENVELOPE COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published b the California Energy Commission. !ZIENV-1-C: Certificate of Compliance. Required on plans for all submittals. Part 2 may be incorporated in schedules on plans. DENV-2-C: Used Envelope Component compliance method !ZIENV-3-C: Used with Overall Envelope Compliance method !ZlENV-4-C: Optional. Use for minimum skylight requirements for large enclosed spaces EnergyPro 4.3 by EnergySoft User Number: 6272 Job Number: Page:1 of 56