4.106.2 A plan is developed and implemented to manage storm water drainage during construction.
4.106.3 The site shall be planned and developed to keep surface water away from buildings.
Construction plans shall indicate how site grading or a drainage system will manage all surface water
flows.
4.303.1 Indoor water use shall be reduced by at least 20 percent using one of the following methods:
1. Water saving fixtures or flow restrictors shall be used.
2. A 20 percent reduction in baseline water use shall be demonstrated.
4.303.2 When using the calculation method specified in Section 4.303.1, multiple showerheads shall not
exceed maximum flow rates.
4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and shower heads) shall
comply with specified performance requirements. ,,,-~~,,..,,...,--.,._,,,~,...,,,='
4.408.1 A minimum of 65 percent of the construction waste generated at the site is diverted to recycle or
salvage. Recycled material receipts from approved recyclers must be attached to this form.
4.408.2 Where a local jurisdiction does not have a construction and demolition waste management
ordinance. construction waste management plan, per form B-59, shall be submitted for approval to the
enforcin a enc .
'iit;~iig'llahif _{. ei'Zi§ii!ifF\,i7:,, .;
4.503.1 Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed
(X)
7/01/2011
(X)
7/01/2011
(X)
woodstove or pellet stove shall comply with US EPA Phase II emission limits where applicable. (X)
Woodstoves, pellet stoves and fireplaces shall also com I with a plicable local ordinances.
:;, All co..--,;tvi,1d;,, r.Jp$je. ~,.,,:, oA-.,,;fe a"J e,.,;\.I b.e. r-ecyc~J(,;-A/Vt¥jed upori
Co..i-f/di<>>i c,f-')..n.l ph.A.se, wi,,·c.i-115 u.,.,k,.r ">~P<><r ... k-pe/'),1,,1} ~ Cf1,p..A '2018' ~ OO'-t-{.
B-51 I Page 1 of 2 Rev. 5/17
Pollutant Control
4.507.1 Whole house exhaust fans shall have insulated louvers or covers which close when the
fan is off. Covers or louvers shall have a minimum insulation value of R-4.2.
4.507.2 Duct systems are sized, designed. and equipment is selected using the following
methods:
1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent.
2. Size duct systems according to ACCA 29-D (Manual D) or equivalent
3. Select heatin and coolin e ui ment accordin to ACCA 36-S Manual S or e uivalent.
702.1 HVAC system installers are trained and certified in the proper installation of HVAC
systems.
702.2 Special inspectors employed by the owner must be qualified and able to demonstrate
com etence in the disci line the are ins ectin .
(X)
(X)
(X)
(X}
(X}
(X)
(X)
(X)
(X)
(X)
(X)
I, as the professional responsible for this project, certify that, to the best of my knowledge, the mandatory items
listed on this form have been incorporated into the project in order to comply with Title 24, Part 11 of the 2016
California Green Building Standards. All receipts for recycled materials have been attached to this form.
Project Address: 1 S 7 Ch~s r"' ...,f-!t-v '-
Print Name: _ _,_\-+-'-'tt-"_\_<-_lL-_,_~------
Plan Check Number: pc,. 2-ott"-Oo(O
Signed: _\b'~+--"::.=..,~{A_--==-r---
License Number: Oivt,i,,t,fr Date: __ 3i...:...· -==2..'-'")_---'-1 "'I.....__
B-51 Page 2 of 2 Rev. 5117