Loading...
HomeMy WebLinkAbout1580 CANNON RD; ; CB120737; Permit09-24-2012 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB120737 Building Inspection Request Line (760) 602-2725 Job Address: Permity Type: Parcel No: Valuation: Occupancy Group: Project Title: 1580 CANNON RD CBAD Tl Sub Type: COMM 0000000000 Lot #: 0 $29,473.00 Construction Type: NEW Reference # LAGOON CENTER: 794 SF Tl NO CHANGE IN USE Status: ISSUED Applied: 04/23/2012 Entered By: JMA Plan Approved: 09/24/2012 Issued: 09/24/2012 Inspect Area Plan Check #: Applicant: DZN PARTNERS Owner: 682 2ND ST ENCINITAS OA 92024 760-753-2464 Building Permit $309.22 Meter Size Add'l Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00 Plan Check $216.45 Meter Fee $0.00 Add'l Building Permit Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $6.19 PFF (3105540) $0.00 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $100.00 Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $55.00 Other Building Fee $0.00 MECHANICAL TOTAL $45.50 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Reel. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (SB1473) Fee $1.00 HMP Fee ?? Fire Expedidted Plan Review $0.00 Green Bldg Standards Plan Chk ?? TOTAL PERMIT FEES $733.36 Total Fees: $733.36 Total Payments To Date: $733.36 Balance Due: $0.00 Inspector: FINAL APPROVAL Date: f'/ Clearance: NOTICE: Please take NOTICE that approval of your project Includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refen-ed to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Govemment Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attacl(, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified lees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fsfts/fixadions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previousiv othenvise expired. CITY CARLSBAD Building it Appiication O F 760-602-2717/2718/2719 Fax 760-602-8558 www.carlsbadca.gov Plan Check No. Plan Ck. Deposit PP-(^\lf-S^ Date SWPPP JOBADDRESS , — _ , SUI1E*/SPACE#/UNIT* APN 01 -- 00 CT/PROJECT # LOT# PHASE# #0F UNITS \ # BEDROOMS # BATHROOMS 3 TENANT BUSINESS NAME dO^K) CONSTR. TYPE NJ V--5 occ. GROUP DESCRIPTION OF WORK: fncfude Square Feet of Afl ected Areafs; A AIRCOND/IONING FIRE SPRINKLERS/ YESQNO[2] EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES[~1» YESI APPLICANTNAME (Primary Contact) APPLICANTNAME (Secondary Contact; ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL PROPERTYOWNERNAME CONTRACTOR iCTOR BUS. NAME , ^ ADDRESS ( 5 Bo <::UtHKjoM g.r> .UTATF ADDRESS „ 1 - CITY ZIP PHONE ^ ^ _ _ _ . FAX PHONE 76D FAX rnunc --v _ TAA ;|0DQ^\^-n-70|l no o-e EMAIL (iS^ @^ '^^qv;^^e/\g{^ . o STATEUCS , _ _ CLASS 'CITY BISS. LIC,# ' ARCH/DESIGNER NAME & ADORESS _ ^,.„.^,.,., _ . u..,.„ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permitto construct, alter, improve, demolish or repair any structure, priorto its issuance, also requires the applicantfor such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Cliapter 9, commending with Section 7000 of Division 3 ofthe Business and Professions Code) or that he is exempt therefrom, and the basis forthe alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). WORKERS' COMPENSATION Workers' Compensation Declaration: / herety affirm under penalty of perjury one of tie following declarations: HI have and will maintain a certificate of consent lo self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the worft for which this pemiit is issued. I have and will maintain worlters' compensation, as reguired bv Section 3700 of the Labor Code, for the performanceof the wortt for which this permit is issued. My wortters'compensation insurance carrier and policy number are: Insurance Co. Policy No. Expiration Date -fflgsection need not be completed if the permit is for one hundred dollars ($100) or less. BMCertificate of Exemption: I certify ttiat in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of 'ualimmia. WARNING: Failure to secure workers' com>eTTM(lon coveraoe is unlawful, and shall subject an employer to criminal penaltiesandcivilfinesup to one hundred thousand dollars (&100,000), in addition to the cost of compW^jg^4afiages as pro«|led forta Secti«ip706 of the Labor code, interest and attomey's fees. ^ CONTRACTOR SIGNAjKmrNmj C\Q\ flflU ^ QAGENT DATE 9, ZO 1 7^ OWNER-BUILC^€!: DECLARATION / hereby affimi fia( / am exempf fora Contractor's Ucense Law for tie following reason: I, as owner of the property or my employees with wages as theirsole compensation, will do the work and the structure is not intended or offered fbr sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered fbr sale. If, however, the building or improvement is sold vwthin one year of completion, the owner-builder will have the burden of proving that he did not build or improve fbr the purpose of sale). • • • I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Businessand Professions Code: The Contractor's license Lawdoes not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). Business and Prafessions Code for this reason: I am exempt under Section 1.1 personally plan to provide the major labor and materials for construction of the proposed praperty improvement. •Yes Oo 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the fbllowing person (firm) to pravide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to pravide portions of the work, but I have hired the following person to coordinate, supen/ise and pravide the major wodt (include name/address/phone / contractors'license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): > PROPERTY OWNER SIGNATURE •AGENT DATE COMPLETE THIS SECTION FOR NON-nESIDEN> ING PERMITS ONLY Is the applnant or future building occupant lequired to submit a business plag,.4il)tely hazardous materials regislralion form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes (fNo/ Is the applicant or future buiiding occupant required to obtain a pemiit from thSar poliutnn control distrnt or air quajjiy management district? Yes Is the facility to be constmcted wilhin 1,000 feet of the outer boundary of a school site? Yes /T3O) IF ANY OF THE ANSWERS ARE YES. A RNAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPUCANT HAS IMET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affimi that there is a construction lending agency for the performance ofthe work this permit is issued (Sec. 3097 (Q Civil Code). Lender's Name , Lender's Address APPLICANT CERTIFICATION IceitlfyttiatI have read the appicalion and state that theaboveinfomiation Is conect and that theinfbmia I hereby authorize representative of the City of Carisbad to enter upon the above mentioned property fbr inspeclion purposes. I ALSO AGREE TO SAVE, INI3EMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABIUTIES, JUDGH^ENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAD CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pemnit is required for excavations over 5'0' deep and demditon or constmction of structures over 3 stories in height EXPIRATON: Every permit issued by the Building Oflicial under the provisk/isoFlhis.^e shall expire by limitation and become nuH and void If tie building or wortt authorized by such peimit is not commenced within 180 days i'om tie dale of such peimit or if the building or worit ai4hoiized by^^ch perniiris.suspended or abandoned at any time alter the worit is commenced for a period of 180 days (Sectbn 106.4.4 Unifbim Building Code). VCJ'APPUCANT'S SIGNATURE DATE -f-. -Z,^. STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email www.buildinaiacai1sbadca.Qov or Mall the completed fbim to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, Califomia 92008. C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX ElVIAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPnONS PICK UP: CONTACT (Usted above) OCCUPANT (Usted above) CONTRACTOR (On Pg. 1) MAILTO: CONTACT (Usted above) OCCUPANT (Usted above) CONTRACTOR (On Pg. 1) MAIL / FAX TO OTHER: ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ^APPLICANTS SIGNATURE DATE Inspection List Permit*: CB120737 Type: Tl COMM Date Inspection Item 04/01/2014 89 Final Combo 04/01/2014 89 Final Combo 03/25/2014 19 Final Structural 03/25/2014 19 Final Structural 02/07/2014 17 Interior Lath/Drywall 01/30/2014 84 Rough Combo 01/15/2014 11 Ftg/Foundation/Piers 01/14/2014 21 Underground/Under Floor 11/05/2013 92 Compliance Investigation 11/27/2012 89 Final Combo 11/07/2012 17 Interior Lath/Drywall 10/16/2012 14 Frame/Steel/Bolting/Weldin 10/16/2012 34 Rough Electric 10/10/2012 11 Ftg/Foundation/Piers Inspector PB PB PB PB PB PB PB PB PB PB PB PB Act Rl AP Rl CO AP AP AP AP AP NR AP AP AP AP LAGOON CENTER: 794 SF Tl NO CHANGE IN USE Comments COF PM PLS AFTER 2:30 PL COF Wednesday, April 02, 2014 Page 1 of 1 INSPECTION RECORD / ^ CITY Ot CARLSBAD Building Divbion B INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB m CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadca.QOV/BulldlnQ AND CUCK ON "Request Inspection" DATE: CB120737 1580 CANNON RD LAGOON CENTER. 794 SF Tl NO CHANGE IN USE Tl COMM Lot#: DZN PARTNERS ORD COPY If YES IS checUed the Division s approval is required prior to requesting a Final Building Inspection. It vein luivi; .iiiy t|Li!;'',!,oii'; [)ii;ar.i; iht; ,i()C)li(-nl)!(! i nv isiriiis .n iiio piuini; iuiirinf:rs |)[ (ivn olf ' I lA to 760-602-8560, i-in.ijl to bldqinspectionsCajcarlsbadca.ciov (ji iiriiKj iii ,i UL C.irlsb;id. CA <>;'O08 Ruildinq Inspt.-clors can be u;,'ichc;d :n 760-602-2700 botweon /' 30 jiti - ,iniis .it ttio plioni I i|MO'.. .lis ,11 Ji.Kljy Av't; '.[lo'Llion YES Required for Buiiding Finai If Clieciced YES Date Inspector Notes Planning / Landscape 760-944-8463 Allow 48 hours CM&I (Engineering Inspections) 760-438-3891 Call before 2 pm Fire Prevention 760-602-4660 Allow 48 hours Type of Inspection Date inspector Type of Inspection Date inspector BUILDING ELECTRICAL FOUNDATION -L IP^' ]' 0 k • ELECTRIC UNDERGROUND • UFER REINFORCED STEEL |D ROUGH ELECTRIC WALLS ll . 1/ -. MASONRY ROUGH ELECTRIC CEILING • GROUT • WAU DRAINS • ELECTRIC SERVICE • TEMPORARY TILTPANELS • BONDING • POOL POUR STRIPS PHOTOVOLTAIC COLUMN FOOTINGS HNAL SUBFRAME • nOOR • CEIUNG MECHANICAL ROOFSHEATHING UNDERGROUND DUCTS & PIPING EXT. SHEAR PANELS • DUCT & PLENUM •REF. PIPING FRAME HEAT-AIR COND. SYSTEMS si INSUUTION VENTILATION SYSTEMS jO-'(ir 1" EXIERIORIATH HNAL INTERIOR LATH & DRVWAU /A 7-/2. HNAL OCCUPANCY PLUMBING Date Inspector FIRE Date Inspector • SEWER &BI/CO • PL/CO A/S UNDERGROUND VISUAL UNDERGROUND • WASTE • WATER A/SUNDERGROUND HYDRO TOPOUT DWASTE • WATER A/S UNDERGROUND FLUSH TUB & SHOWER PAN A/S OVERHEAD VISUAL • GAS TEST • GAS PIPING A/S OVERHEAD HYDROSTATIC • WATER HEATER DSOIAR WATER A/S HNAL HNAL F/AROUGH-IN STORM WATER F/A HNAL 600 - PRE-CONSTRUCnON MEETING HXED EXnNGUISHING SYSTEM ROUGH-IN 603-FOUOW UP HXED EXHNG SYSTEM HYDROSTATIC TEST 605-NOTICETO CLEAN FIXED EXTINGUISHING SYSTEM HNAL 607-WRITTEN WARNING MEDICAL GAS PRESSURE TEST 609-NOTICE OF VIOLATION MEDICAL GAS HNAL 610-VERBALWARNING HNAL SEE BACK FOR SPECIAL NOTES Section 5416. Health and Safety Code, State of California (a) There shall be not less than one water closet for each 20 employees or fractional part thereof working at a construction job site. The water closet shall consist of a patented chemical type toilet (b) For the purpose of this section the term construction site shall mean the location on which actual construction of a building is in progress. (c) A violation of this section shall constitute a misdemeanor. Atl construction or work for which a permjt is required shall be subject to inspection and all such construction or work shall remain accessible and exposed for inspection purposes until approved by the inspector. Work shali not be done beyond the point indicated in each successive inspection without first obtaining the approval ofthe inspector. DATE ADDITIONAL NOTES ¥ 3i CITV OP INSPECTION RECORD .ARLSBAD Juilding Division EI INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB EI CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION EI FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carisbadca.ffov/Bulldinq AND CLICK ON "Request Inspection" . DATE: tUllH CB120737 1580 CANNON RD LAGOON CENTER: 794 SF Tl NO CHANGE IN USE Tl COMM Lot#: DZN PARTNERS RECORD COPY IF "YES" IS CHECKED BELOW THAT DIVISION S APPROVAL IS REQUIRED PRIOR TO REQUESTING A FINAL BUILDING INSPECTION. IR YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW AFTER ALL REQUIRED APPROVALS ARE SIGNED OFF- FAX TO 760-602-8560. EMAIL TO BLDGiNSPECTioNSiiPcAHLSBADCA GOV OR BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE.. CARLSBAD. CA 92008 BUILDING INSPECTORS CAN BE REACHED AT 760-602-2700 BETWEEN 7:30 AM - 8;00 AM THE DAY OF YOUR INSPECTION. NO YES ' Required Prior to Requesting Building Final If Cfieciced YES Date Inspector Notes Planning/Landscape 760-944-8463 Allow 48 hours CM&I (Engineering Inspections) 760-438-3891 Call before 2 pm Fire Prevention 760-602-4660 Allow 48 hours t 1 ' O Type of Inspection Type of Inspection CODE # BUILDING 1 Date inspector CODE # ELECTRICAL 1 Date Inspector #11 FOUNDATION #31 D ELECTRIC UNDERGROUND DUFER #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 • ELECTRIC SERVICE • TEMPORARY • GROUT • WALL DRAINS #35 PHOTOVOLTAIC #10 TILTPANELS #39 HNAL #11 POUR STRIPS CODE # MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME • FLOOR • CEILING #44 • DUCT & PLENUM • REF. PIPING #15 ROOFSHEATHING #43 HEAT-AIR COND. SYSTEMS' #13 EXT. SHEAR PANELS #49 HNAL #16 INSUUTION CODE « COMBO INSPECTION #18 EXTERIOR UTH #81 UNDERGROUND (11,12,21,31) #17 INTERIOR UTH & DRYWALL #82 DRYWALL,EXr UTH, GAS TES (17,18,23) #51 POOLEXCA/STEEL/BOND/FENCE #83 ROOFSHEATING,EXTSHEAR(13,1S) #55 PREPIASTER/HNAL #84 FRAME ROUGH COMBO (14,24,34,44) #19 FINAL #85 T-Bar (14,24,34,44) CODE « PLUMBING Date Inspector #89 RNAL OCCUPANCY (19,29,39,49) | #22 • SEWER & BL/CO GPL/CO FIRE Date Inspector #21 UNDERQROUND DWASTE • WTR #24 TOPOUT DWASTE DWTR A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO #23 DGASTEST • GAS PIPING A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL #28 SOUR WATER A/S OVERHEAD HYDROSTAnC #29 HNAL A/S HNAL CODE ** STORM WATER F/AROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A HNAL #603 FOLLOW UP INSPECTION HXED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICETO CLEAN FIXED EXTING SYSTEM HYDROSTATICTEST #607 WRITTEN WARNING HXED EXTINGUISHING SYSTEM HNAL #609 NOTICE OF VIOUTION MEDICAL GAS PRESSURE TEST #610 VERBALWARNING MEDICAL GAS HNAL SEE BACK FOR SPECIAL NOTES Section 5416. Healtii and Safety Code, State of California (a) There shall be not less than one water closet for each 20 employees or fractional part thereof working at a constmction job site. The water closet shall consist of a patented chemical type toilet. (b) For the purpose of this section the term construction site shall mean the location on which actual construction of a building is in progress. (c) A violation of this section shall constitute a misdemeanor. All constnjction or work for which a pennit is required shall be subject to inspection and all such constmction or work shall remain accessible and exposed for inspection purposes until approved by the inspector. Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the inspector. .1 DATE ADDITIONAL NOTES BREITilLBUIVGEI? SPECIAL IHSPECTIONS 7380 Park Ridge Blvd. Unit 124 • San Diego, CA 92120 (858) 205-2333 /GfiO//CC ALL CITIES & JURISDICTIONS INSPECTION & MATERIAL TESTING REGISTERED INSPECTOR'S DAILY REPORT Job Itambwr • structural steel Assembly • Fireproofing • Asphalt ihtrol ' TYPE OF INSPECTION REQUIRED • Reinforced Concrete • Post Tensfoned Concrete • Structural Masonry • Quality Cohtrol HC![Epoxy Anchors Other CMy PMTnU Numbar ltaMMDm«ilp8M(tyfW,gcwta.sauR»r ; AreMttct VA Engbwar Conowlor InsfMcloni- Nome Brett Alblinger INSPECTION SUMMARY - Subcantrsdor j LOCATIONS OF WORK INSPECTED. TEST SAMPLES TAKEN. WORK REJECTED, JOB PROBLEMS. PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE AND IDENTIFICATION NUMBERS OF SAMPLES TAKEN. STRUCTURAL CONNECTIONS (WELD MADE H.T. BOLTS TORQUED) Ct^CKED. ETC. 4 2^ A ^'^7 :^4^,jrl><y^ ^.i^^^^fwv :^:^-.^.r> ^ r^^jiy i-7^,^!x\p^-^ SAMPLES MQRTAR GROUT gtOCK PRISMS JQENSIDL CERTIFICATION OF COMPLIANCE: To the tMSt of my iuwwiedge, all of 8« rspoiled wnic, unIm olheiwiM noted, is bl cx>nfsnTiarK» wilh M appm appieabfe teolians of the govMTMng bu8ding laws. CediflcaUon NumtMH- /CC# 088^693-88/84/89 EsGil Corporation In (Partnersfiip witfi government for (BuiCding Safety DATE: AUGUST 27, 2012 QJPBUC^m ^uRis. y JURISDICTION: CARLSBAD •"PtiAN^VIEWER • FILE PLANCHECKNO.: 12-0737 SETHI PROJECTADDRESS: 1580 CANNON ROAD PROJECT NAME: Interior Remodel for Hedionnda Lagoon Discovery Center I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ^ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I 1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. I I The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: r Telephone #: Date contacted: (by: ) Email: r\\/// Fax #: Mall Telephone Fax In Person 3 REMARKS: As per architect, the city has approved /lew Women #2 (multiple accommodation) on Sheet a.03 not to comply with HC accessibility/due to hardship, City to please verify. Also, see notes and items in red ink and highliglited on Sheets P2.1 & P4.1. By: ALI SADRE ^ Enclosures: EsGil Corporation • GA • EJ • PC 8/21 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partnersfiip witfi government for (BuiCding Safety DATE: AUGUST 1, 2012 IXAPPLICANT 4.JURI$? JURISDICTION: CARLSBAD • PLAN REVIEWER • FILE PLANCHECKNO.: 12-0737 SET II PROJECTADDRESS: 1580 CANNON ROAD PROJECT NAME: Interior Remodel for Hedionnda Lagoon Discovery Center I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. PLEASE SEE BELOW I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. The applicant's copy of the check list has been sent to: DZN Partners 682 2"*^ Street, Encinitas, CA 92024 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. 1X1 EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: DZN Partners (Bart) Telephone #: 760-753-2464 Date contacted: STI I '/^ (by: ) Email: b.smith@dznpartners.com— Fax #: -0600 t Mall Telephone Fax In Person XI REMARKS: Please see attached for remaining items from previous list. By: ALI SADRE Enclosures: EsGil Corporation IE! GA • EJ • PC 7/26 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 • GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. . ACCESSIBILITY 2. New Women 2 restroom and revised Men 1 restroom must be accessible. As per response, city is reviewing an exemption due to hardship. See the next item too. 3. Imprint all the attached HC requirements on plans and revise the plans accordingly. Do not resubmit without these changes on plans unless exemption grated to all attached items by the building official. . ADDITIONAL 4. Please see attached for P/M/E & HC items. 5. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 6. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone numberof 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE at Esgil Corporation. Thank you. NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers ofthe items are from the previous check list and may not necessarily be in sequence. THE NOTES IN BOLD FONT ARE CURRENT REMAINING ITEMS. PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek GENERAL AND ARCHITECTURAL PME ITEMS 14. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. PLUMBING (2010 CALIFORNIA PLUMBING CODE) 16, Correct the water line sizing calculation on sheet P1.1 as per the following: Provide complete water line sizing calculations for the revised new water demands: Include the water pressure, pressure loss calculations, water demands, and the developed pipe lengths. UPC 610.0 or Appendix 'A'. A) Correct water demand calculations to show both the existing to remain plus the new water demands. All the existing to remain are not shown. B) Correct water demand for the flush valve urinal to be 4 fixture units. C) Only the added fixture units are used in the water line sizing calcualations. (12.5 fixture units.) I count a total of 24.5 fixture units. D) The proposed VA, inch water line to the new urinal is undersized. The calculations require minimum VU inch water line to the flush valve urinal. E) The existing 1 inch cold water main line from the water meter to the new water line connections is undersized for the total existing to remain plus the new water demands. Please correct 17. New Women 2 restroom and revised Men 1 restroom must be accessible. As per response, city is reviewing an exemption due to hardship. Correct the layouts for the New Women 2 restroom to show the "Disabled Access" clearances. 20. Please verify the next upstream sewer manhole rim elevation compared to the finished floor elevation before the permit is issued. If the next upstream sewer manhole rim elevation is higher than the finished floor elevation then back water valves are required and must be shown on the drain waste and vent drawings. Please provide for plan check review. Please show the upstream sewer manhole rim and finished floor elevations. Provide backwater valves for all fixtures installed on floor levels below the next upstream manhole rim elevation. (Only fixtures installed on floor levels below the next upstream manhole rim elevation may flow through a backwater valve.) UPC 710.1 MECHANICAL (2010 CALIFORNIA MECHANICAL CODE) 21. Please address the following: Provide complete mechanical plans showing existing and proposed HVAC equipment, ducts, and access to all equipment. A) Meeting room 2 floor area is larger, part of the Hall 1 is now part of the meeting room. More outside air is required for Meeting room 2. B) The plans do not show how return air for Meeting room 2 is to be provided. The new door between the Hall 1 and the Meeting room 2 blocks the air flow from the Meeting room 2 back to the return air grill in the Hall. Please correct. 23. Please provide MECH-3 forms for the Meeting room 1 and Meeting room 2 and the Hall 1 as per item #21 above. Please provide the MECH-3-C forms showing the required mechanical ventilation rates for the new or revised conditioned spaces. Coordinate the mechanical and the Title 24 outside air design. CMC 403.0 & Title 24 121(b)2 & (d). Please provide MECH-3-C forms forthe HVAC units serving revised Meeting 1, revised Meeting 2 and revised Office 3, for the revised ventilation requirements. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT - TITLE 24 The following disabled access items are taken from the 2010 edition of Califomia Building Code, Title 24. Per Section 1.9.1, aii publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. Reflect the following items on plans. Revise tiie multiple batiiroom plans accordingly. • SITE PLAN REQUIREMENTS 1. Clearly show that the site development and grading are designed to provide access to all entrances and exterior ground floor exits, as well as access to normal paths of travel, per Section 1127B.1. Where necessary to provide access, shall incorporate pedestrian ramps, curb ramps, stairways and handrails, etc. 2. When more than one building or facility is located on a site, accessible routes of travel shall be provided between buildings and accessible site facilities, per Section 1127B.1. 3. The accessible route of travel shali be the most practical direct route between accessible building entrances, accessible site facilities, and the accessible entrance to the site. Section 1127B.1. 4. Note that at every primary public entrance, and at every major function area along, or leading to, an accessible route of travel, there is to be a sign displaying the international symbol of accessibility. Signs are required to indicate the direction to accessible building entrances and facilities, per Sections 1117B.5.7 and 1127B.3. 5. Show that an accessible route of travel is to be provided to all portions of the building, to accessible building entrances and between the buildinq and the public wav. per Section 1114B. 1.2. 6. Where more than one route of travel is provided, all routes shall be accessible. Section 1114B.1.2. 7. Show that a 36" wide detectable warning material is provided at boundaries between walkways and vehicular ways. Section 1133B.8.5. 8. Show that stairways occurring outside a building comply with Section 1133B.4.4 as follows: a) The upper approach and all treads shall be marked with a strip of contrasting color as follows: i) >2" in width; Placed parallel to and ^1" from the nose ofthe step or landing. ii) The strip is required to be as slip resistant as the treads of the stairs. b) Treads shall be: i) Have no abrupt edges at the nosing projecting £1 Vi" past the face of the riser above. ii) Smooth, rounded or chamfered exposed edges; Open risers are not permitted. a ACCESSIBLE PARKING 9. Show on the site plan the required number of accessible parking spaces for new facilities. Per Table 11 B-6 the minimum number of spaces is: a) 1 for each 25 spaces up to 100 total spaces. b) 1 additional space for each 50 spaces for between 101 and 200 total spaces. 10. Show that the accessible parking spaces are located, per Section 1129B.1 as follows: a) On the shortest possible route to an accessible entrance, when serving a particular building. b) On the shortest route of travel to an accessible entrance of a parking facility. c) Spaces are to be dispersed and located closest to accessible entrances where buildings have multiple accessible entrances with adjacent parking. 11. At least one in every 8 accessible parking spaces (but not less than one) shall be served by an access aisle >96" in width and designated as VAN ACCESSIBLE, per Section 1129B.3.2. 12. Show that accessible parking spaces comply with Section 1129B.3.1 as follows: a) Single spaces shall be 14' wide and outiined to provide a 9' parking area and a 5' loading and unloading area on the passenger side of the vehicle. b) When more than one space is provided, in lieu of providing a 14' space for each space, two spaces can be provided within a 23' area with a 5' loading zone between each 9'0" wide space. c) Each space is to be a minimum of 18' in depth. 13. The words "NO PARKING" shall be painted on the ground within each loading and unloading access aisle (in white letters no less than 12" high & located so that it is visible to traffic enforcement officials). Sec. 1129B.3.3. 14. Ramps shall not encroach into any accessible parking space or the adiacent access aisle. Section 1129B.3.3. 15. Show on the site plan that accessible parking space(s) are to be located such that disabled persons are not compelled to wheel or walk behind parked cars other than their own, per Section 1129B.3.3. 16. Show that a bumper or curb is to be provided, and located at each space, to prevent encroachment of cars into the required width of walkways, per Section 1129B.3.3. 17. Show or note that the maximum slope of the parking surface at the accessible space and adjacent access aisle, in any direction, is s 1:50 (2%), per Section 1129B.3.4. 18. Show, or note, that an additional sign shall also be posted in a conspicuous place at each entrance to off street parking facilities, or immediately adjacent to and visible from each stall or space. The sign shall be >17" x 22" with lettering not ^1" in height. Per Section 1129B.4 required wording is as follows. "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at or by telephoning ." 19. Show or note on the plans that the accessible parking spaces are to be identified by a reflectorized sign, permanently posted immediately adjacent to and visible from each space, consisting of: a) A profile view of a wheelchair with occupant in white on dark blue background. b) When in the path of travel, they shall be posted >80" from the bottom of the sign to parking space finished grade.; The sign shall >70 in.^ in area. c) Signs may also be centered on the wall of the interior end of the parking space >36" from the parking space finished grade, ground or sidewalk. d) Spaces complying with Section 1129B.4.2 shall have an additional sign "Van-Accessible" mounted below the symbol of accessibility per Section 1129B.4. e) In addition, the surface of each accessible space is required to be marked with the international symbol of accessibility. a CURB RAMPS 20. Curb ramps shall be constmcted where a pedestrian way crosses a curb or at each corner of a street intersection, per Section 1127B.5.1. 21. Plans shall show that curb ramps are >48" wide with a slope of si: 12 (8.33%), per Sections 1127B.5.2 and 1127B.5.3. The lower end of each curb ramp shall have a Vi" lip beveled 45°, per Section 1127B.5.5. 22. Show that the landing at the top of the curb shall be level and >48" depth for the entire width of the curb ramp. Section 1127B.5.4; The slope of the fanned or flared sides of curb ramps shall not exceed 1:10, per Section 1127B.5.3; Locate curb ramps to prevent obstruction by blocked cars, per Section 1127B.5.8. 23. Show that detectable warnings, extending the full width and depth ofthe curb ramp, inside the grooved border, are to be installed for all curb ramps (regardless of slope), per Section 1127B.5.7. These consist of raised truncated domes with a diameter of 0.9" at the base, tapering to 0.45" at the top. Spacing shall be 2.35" o.c. Only approved DSA/AC detectable warning products and directional surfaces shall be installed. 24. Show or note that the surface of all curb ramps and the flared sides are to be slip resistant, and contrasting from the adjacent sidewalk finish, per Section 1127B.5.5. 25. Provide details or note on the plans that all curb ramps have a grooved border 12" wide at the level surface of the sidewalk along the top and each side approximately ^IA O.C, per Section 1127B.5.6. a WALKS AND SIDEWALKS 26. If any proposed walks slope >1:20 (5%) they must comply with ramp requirements, per Section 11338.5.1. 27. The maximum permitted cross slope shall be %" per ft., per Section 1133B.7.1.3. 28. Show or note that any abrupt level changes will be ^Vi along any accessible route of travel. When changes do occur, they shall be beveled with a slope of si :2. Level changes of s%" may be vertical. NOTE: If level changes >!4", they must comply with the requirements of curb ramps. 29. Walks along an accessible route of travel are required to be >48" minimum in width and have slip resistant surfaces, per Section 1133B.7. a DOORS 30. Show, or note, that there is a level floor or landing on each side of all doors. The floor or landing is to be SV2" lower than the doonway threshold, per Section 1133.2.4.1. 31. Note that all hand-activated door opening hardware meets the following requirements, per Sec. 1133B.2.5.2: a) Latching, or locking, doors in a path of travel are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. b) Is to be centered >30" but S44" above floor. 32. Show or note that the maximum effort to operate doors shall not exceed 8-'!^ pounds for exterior doors and 5 pounds for interior doors, with such pull or push effort being applied at right angles to hinged doors and at the center plane of sliding or folding doors. When fire doors are utilized, the maximum effort to operate the door may be increased to not exceed 15 pounds. Section 1133B.2.5. 33. Show or note that the lower 10" of all doors comply with Section 1133B.2.6, as follows: a) To be smooth and uninterrupted, to allow the door to be opened by a wheelchair footrest, without creating a trap or hazardous condition. b) Narrow frame doors may use a 10" high smooth panel on the push side ofthe door. a SANITARY FACILITIES 34. Note that the doonways leading to sanitary facilities shall be identified, per Section 1115B.6, as follows: a) An equilateral triangle %" thick with edges 12" long and a vortex pointing upward at men's rest rooms. b) A circle %" thick, 12" in diameter at women's rest rooms. c) A 12" diameter circle with a triangle superimposed on the circle and within the 12" diameter at unisex rest rooms. d) The required symbols shall be centered on the door at a height of 60". e) Braille signage shall also be located on the wall adjacent to the latch outside of the doonvays leading to the sanitary facilities, per Section 1117B.5.1. • RESTROOM FIXTURES AND ACCESSORIES (Applies to multiple accommodation) 35. Show that accessible lavatories comply with the following, per Sections 1115B.4.3: a) >30" X 48" clear space is provided in front for fonward approach. The clear space may include knee and toe space beneath the fixture. b) When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall; The counter top is s34" maximum above the floor. c) >29" high, reducing to 27" at a point located 8" back from the front edge. d) >9" high x 30" wide and 17" deep at the bottom; Hot water pipes and drain lines are insulated. 36. Show, or note, on the plans that the accessible water closets meet the following requirements. Sec. 1115B.4.1: a) The seat is to be >17" but si 9" in height. b) The controls for flush valves shall be: Mounted on the side of the toilet area; Be S44" above the floor. 37. Show, or note, on the plans that accessible urinals meet the following requirements, per Section 1115B.4.2: a) The rim of at least one urinal shall: Project at least 14" from the wall; Be si 7" above the floor. b) The control mechanism is to be located S44" above the floor. c) >30" X 48" clear floor space is provided in front of the accessible urinal. Section 1115B.4.2. 38. Show that grab bars comply with the following, per Section 1115B.4: a) Grab bars shall be located on each side or one side and the back of the water closet stall or compartment. b) They shall be securely attached 33" above the floor, and parallel. NOTE: Where a tank-type toilet is used which obstructs placement at 33", the grab bar may be installed as high as 36". c) Grab bars at the side shall be located: i) 15" to 16V2" (±1") from the center line of the water closet stool. ii) Be >42" long with the front end positioned 24" in front of the stool. iii) Total length of bars at the back shall be >36". d) The diameter, or width, of the grab bar gripping surface is >1 %" but si Vi \ or the shape shall provide an equivalent gripping surface. e) If mounted adjacent to a wall, the space between the wall and the grab bar shall be V/i'. 39. Per Section 1115B.8, show on the plans S40" height for: a) The operable parts of at least one: i) Paper towel dispenser; Sanitary napkin dispenser. ii) Waste paper disposal; Other similar dispensing and/or disposal fixtures. b) The bottom edge of mirrors. a MULTIPLE ACCOMMODATION SANITARY FACILITIES 40. Show that the accessible rest room is to be provided with a 60" minimum diameter clear space measured from the floor to a height of 27 inches. NOTE: Doors (other than the door to the accessible toilet compartment) in any position may encroach into this space by not more than 12 inches, per Section 1115B.3.1. 41. Doors shaW not swing into tfie clear floor space required for any fixture wittiin ttie toilet facility. Section 1115B.3.1.2. 42. Show that at least one water closet fixture, located in a compartment, shall provide the following, per Section 1115B.3.1.4: a) >28" clear space from a fixture (or ^32" clear space from a wall) at one side. b) The other side of the water closet shall provide 18" from the centerline of the water closet to the wall. c) The compartment shall be a minimum of 60" wide. d) Clear space in front of the water closet shall be: i) >48" if the compartment has an end opening door. ii) >60" is required for side opening doors. e) Grab bars shall not project more than 3" into the clear spaces indicated. 59" MIN. AT FLOOR-MOUNTED W.C. WHEN DOOR SWINGS IN 56" MIN. AT WALL-MOUNTED W.C. WHEN DOOR SWINGS IN 54" MIN FLUSH ACTWATOR ON WIDE SIDE 43. Show or note, per Section 1115B.3.1.4 that the doors to the accessible water closet compartment wiii be equipped with a self closing device with: a) >32" clear opening width when located at the end of the compartment. b) >34" clear opening width when located at the side of the compartment. 44. The door into the accessible water closet compartment shall be provided with a clearance of at least 18" at the strike side of the door, per Section 1115B.3.1.4.5. Additionally, such doors shall have a clear space of not less than 48" as measured at right angles to the door in its closed position. 45. If the water closet compartment has an end-opening door (facing the water closet), the door shall be located on a diagonal to the water closet, witti a maximum stile widtti of 4 incties (see the figure below). Additionally, the door must be provided with a clearance of at least 18" at the strike side. 4'MAX. ACCESSIBLE WATER CLOSET COMPARTMENT WTTHIN A MULTIPLE-ACCOMMODATION TOILET FACtLTrV EsGil Corporation In (Partnersiiip witH government for (BuiCding Safety DATE: MAY 3, 2012 • AEPUCANT JURISDICTION: CARLSBAD • PLAN REVIEWER • FILE PLANCHECKNO.: 12-0737 SET: I PROJECT ADDRESS: 1580 CANNON ROAD PROJECT NAME: Interior Remodel for Hedionnda Lagoon Discovery Center I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Kl The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. Kl The applicant's copy of the check list has been sent to: DZN Partners 682 2"^ Street, Encinitas, CA 92024 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: DZN Partners (Bart) Telephone #: 760-753-2464 Date contacted: S^vl/i- (by: )(^) Email: b.smith(S).dznpartners.com Fax #:-0600 MailTelephoneFax In Person • REMARKS: By: ALI SADRE Enclosures: EsGil Corporation IE! GA IEI EJ • PC 4/23 9320 Chesapeake Drive, Suite 208 • SanDiego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 CARLSBAD 12-0737 MAY 3, 2012 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLANCHECKNO.: 12-0737 JURISDICTION: CARLSBAD OCCUPANCY: A3/B USE: Exhibition Hall TYPE OF CONSTRUCTION: V-B ACTUAL AREA: 794 (T.I.) ALLOWABLE FLOOR AREA: 6,000 STORIES: One 3,490 (Total Area) HEIGHT: 18' SPRINKLERS?: N OCCUPANT LOAD: 30 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 4/23 DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/23 DATE INITIAL PLAN REVIEW COMPLETED: MAY 3, 2012 PLAN REVIEWER: ALI SADRE FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required priorto the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copv) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. • GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. . PLANS 2. Plans shall be stamped & signed by the California state licensed engineer or architect responsible for their preparation. Please include the California license number, seal and date plans are signed. California Business and Professions Code. 3. Include the following code information for the proposed building on Title Sheet: • Occupancy Classification(s): B (Office)/ A3 (Assembly) - Add to plans • For Mixed Occupancy Buildings, state whether the "nonseparated" or "separated" option was chosen from Sections 508.3/508.4. • Description of Use: As per above • Type of Construction: V-B - Ok as noted • Sprinklers: No - Ok as noted • Stories: One - Add to plans • Heiglit 18' - Add to plans • Floor Area: 794 (T.I.) - Ok as noted • Occupant Load: 40 (Remodeled Area) - Ok as noted 4. Provide a statement on the Title Sheet of the plans, stating that this project shall comply with the 2010 California Building Code, which adopts the 2009 IBC, 2009 UMC, 2009 UPC and the 2008 NEC. 5. Identify existing walls to be removed, existing walls to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. Please reflect this on floor plans, i.e.. Sheet a.03. 6. Pleas show interior non-bearing partition details and references on plans. Include the anchorage at top and bottom including shot pins size, spacing, ICC approval #, embedment, etc. on plans. • SITE PLAN 7. Provide a statement on the site plan stating: "All property lines, easements and buildings, both existing and proposed, are shown on this site plan." 8. Please indicate the number of required and provided HC accessible parking spaces on plans including the van accessible spaces on plans. Section 107.2. . ACCESSIBILITY 9. Provide notes and details on the plans to show compliance with the enclosed "Disabled Access" Review List. New Women 2 restroom and revised Men 1 restroom must be accessible. • ADDITIONAL 10. Please see attached for P/M/E & HC items. 11. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 12. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please brieflv describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: • Yes • No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE at Esgil Corporation. Thank you. ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: Eric Jensen 13. Are fine as submitted. Note: If you have any questions regarding this Electrical and Energy plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek GENERAL AND ARCHITECTURAL PME ITEMS 14. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. PLUMBING (2010 CALIFORNIA PLUMBING CODE) 15. Show the required floor drain in the New Women 2 restroom, as per CPC. Section 411.2 16. Provide complete water line sizing calculations for the revised new water demands: Include the water pressure, pressure loss calculations, water demands, and the developed pipe lengths. UPC 610.0 or Appendix 'A'. 17. Correct the layouts for the New Women 2 restroom to show the "Disabled Access" clearances. 18. Provide the following information concerning the water heater: a) Show water heater size and type on plans. UPC 501.0 b) Show that water heater is adequately braced to resist seismic forces. Provide two straps. One strap at top 1/3 of the tank and one strap at bottom 1/3 ofthe tank. UPC 508.2 c) Detail the requirements found in UPC 508.4 & 509.4 for attic installation of water heaters: access opening sizing, passageway description (available height, maximum length and minimum width, walkway material type, platform sizing, the light and receptacle placement, and the overflow protection. 19. Show the required self closing or self closing metering faucets for the lavatories intended to serve the transient public, such as those in, but not limited to, service stations, train stations, airports, restaurants, and convention halls, as per CPC, Section 402.4. 20. Please show the upstream sewer manhole rim and finished floor elevations. Provide backwater valves for all fixtures installed on floor levels below the next upstream manhole rim elevation. (Only fixtures installed on floor levels below the next upstream manhole rim elevation may flow through a backwater valve.) UPC 710.1 MECHANICAL (2010 CALIFORNIA MECHANICAL CODE) 21. Provide complete mechanical plans showing existing and proposed HVAC equipment, ducts, and access to all equipment. 22. Provide the exhaust and make-up air design for the occupancy type listed in Table 4.4. UMC 403.7 Provide exhaust fan sizing calculations for revised Men 1 restroom. The New Women 2 restroom exhaust fan is O.K. 23. Please provide the MECH-3-C forms showing the required mechanical ventilation rates for the new or revised conditioned spaces. Coordinate the mechanical and the Title 24 outside air design. CMC 403.0 & Title 24 121(b)2 & (d). Please provide MECH-3-C forms forthe HVAC units serving revised Meeting 1, revised Meeting 2 and revised Office 3, for the revised ventilation requirements. 24. Detail the primary and secondary mechanical condensate waste design: Pipe sizing, routing, and termination areas. CMC 309.0 & CPC 807.0 Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT - TITLE 24 The following disabled access items are taken from the 2010 edition of Califomia Building Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. Reflect the following items on plans. Revise tfie multiple batfiroom plans accordingly. • SiTE PLAN REQUIREMENTS 1. Cleariy show that the site development and grading are designed to provide access to all entrances and exterior ground floor exits, as weil as access to normal paths of travel, per Section 1127B.1. Where necessary to provide access, shall incorporate pedestrian ramps, curb ramps, stainways and handrails, etc. 2. When more than one building or facility is located on a site, accessible routes of travel shall be provided between buildings and accessible site facilities, per Section 1127B.1. 3. The accessible route of travel shall be the most practical direct route between accessible building entrances, accessible site facilities, and the accessible entrance to the site. Section 1127B.1. 4. Note that at every primary public entrance, and at every major function area along, or leading to, an accessible route of travel, there is to be a sign displaying the international symbol of accessibility. Signs are required to indicate the direction to accessible building entrances and facilities, per Sections 1117B.5.7 and 1127B.3. 5. Show that an accessible route of travel is to be provided to all portions of the building, to accessible building entrances and between the buildinq and the public wav. per Section 1114B. 1.2. 6. Where more than one route of travel is provided, all routes shall be accessible. Section 1114B.1.2. 7. Show that a 36" wide detectable warning material is provided at boundaries between walkways and vehicular ways. Section 1133B.8.5. 8. Show that stainways occurring outside a building comply with Section 1133B.4.4 as follows: a) The upper approach and all treads shall be marked with a strip of contrasting color as follows: i) >2" in width; Placed parallel to and si" from the nose ofthe step or landing. ii) The strip is required to be as slip resistant as the treads of the stairs. b) Treads shall be: i) Have no abrupt edges at the nosing projecting >1 Vi" past the face of the riser above. ii) Smooth, rounded or chamfered exposed edges; Open risers are not permitted. a ACCESSIBLE PARKING 9. Show on the site plan the required number of accessible parking spaces for new facilities. Per Table 11 B-6 the minimum number of spaces is: a) 1 for each 25 spaces up to 100 total spaces. b) 1 additional space for each 50 spaces for between 101 and 200 total spaces. 10. Show that the accessible parking spaces are located, per Section 1129B.1 as follows: a) On the shortest possible route to an accessible entrance, when serving a particular building. b) On the shortest route of travel to an accessible entrance of a parking facility. c) Spaces are to be dispersed and located closest to accessible entrances where buildings have multiple accessible entrances with adjacent parking. 11. At least one in every 8 accessible parking spaces (but not less than one) shall be served by an access aisle 5:96" in width and designated as VAN ACCESSIBLE, per Section 1129B.3.2. 12. Show that accessible parking spaces comply with Section 1129B.3.1 as follows: a) Single spaces shall be 14' wide and outlined to provide a 9' parking area and a 5' loading and unloading area on the passenger side of the vehicle. b) When more than one space is provided, in lieu of providing a 14' space for each space, two spaces can be provided within a 23' area with a 5' loading zone between each 9'0" wide space. c) Each space is to be a minimum of 18' in depth. 13. The words "NO PARKING" shall be painted on the ground within each loading and unloading access aisle (in white letters no less than 12" high & located so that it is visible to traffic enforcement officials). Sec. 1129B.3.3. 14. Ramps shall not encroach into any accessible parking space or the adiacent access aisle. Section 1129B.3.3. 15. Show on the site plan that accessible parking space(s) are to be located such that disabled persons are not compelled to wheel or walk behind parked cars other than their own, per Section 1129B.3.3. 16. Show that a bumper or curb is to be provided, and located at each space, to prevent encroachment of cars into the required width of walkways, per Section 1129B.3.3. 17. Show or note that the maximum slope of the parking surface at the accessible space and adjacent access aisle, in any direction, is s 1:50 (2%), per Section 1129B.3.4. 18. Show, or note, that an additional sign shall also be posted in a conspicuous place at each entrance to off street parking facilities, or immediately adjacent to and visible from each stall or space. The sign shall be si 7" x 22" with lettering not si" in height. Per Section 1129B.4 required wording is as follows. "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at or by telephoning ." 19. Show or note on the plans that the accessible parking spaces are to be identified by a reflectorized sign, permanently posted immediately adjacent to and visible from each space, consisting of: a) A profile view of a wheelchair with occupant in white on dark blue background. b) When in the path of travel, they shall be posted >80" from the bottom of the sign to parking space finished grade.; The sign shall >70 in.^ in area. c) Signs may also be centered on the wall of the interior end of the parking space >36" from the parking space finished grade, ground or sidewalk. d) Spaces complying with Section 1129B.4.2 shall have an additional sign "Van-Accessible" mounted below the symbol of accessibility per Section 1129B.4. e) In addition, the surface of each accessible space is required to be marked with the international symbol of accessibility. a CURB RAMPS 20. Curb ramps shall be constructed where a pedestrian way crosses a curb or at each corner of a street intersection, per Section 1127B.5.1. 21. Plans shall show that curb ramps are >48" wide with a slope of s1:12 (8.33%), per Sections 1127B.5.2 and 1127B.5.3. The lower end of each curb ramp shall have a 14" lip beveled 45°, per Section 1127B.5.5. 22. Show that the landing at the top of the curb shall be level and ^48" depth for the entire width of the curb ramp. Section 1127B.5.4; The slope of the fanned or flared sides of curb ramps shall not exceed 1:10, per Section 1127B.5.3; Locate curb ramps to prevent obstruction by blocked cars, per Section 1127B.5.8. 23. Show that detectable warnings, extending the full width and depth of the curb ramp, inside the grooved border, are to be installed for all curb ramps (regardless of slope), per Section 1127B.5.7. These consist of raised truncated domes with a diameter of 0.9" at the base, tapering to 0.45" at the top. Spacing shall be 2.35" o.c. Only approved DSA/AC detectable warning products and directional surfaces shall be installed. 24. Show or note that the surface of all curb ramps and the flared sides are to be slip resistant, and contrasting from the adjacent sidewalk finish, per Section 1127B.5.5. 25. Provide details or note on the plans that all curb ramps have a grooved border 12" wide at the level surface of the sidewalk along the top and each side approximately ^IA O.C, per Section 1127B.5.6. a WALKS AND SIDEWALKS 26. If any proposed walks slope >1:20 (5%) they must comply with ramp requirements, per Section 1133B.5.1. 27. The maximum permitted cross slope shall be %" per ft., per Section 1133B.7.1.3. 28. Show or note that any abrupt level changes will be Sl4" along any accessible route of travel. When changes do occur, they shall be beveled with a slope of s1:2. Level changes of sVi" may be vertical. NOTE: If level changes >V2", they must comply with the requirements of curb ramps. 29. Walks along an accessible route of travel are required to be >48" minimum in width and have slip resistant surfaces, per Section 1133B.7. • DOORS 30. Show, or note, that there is a level floor or landing on each side of all doors. The floor or landing is to be sVi" lower than the doonway threshold, per Section 1133.2.4.1. 31. Note that all hand-activated door opening hardware meets the following requirements, per Sec. 1133B.2.5.2: a) Latching, or locking, doors in a path of travel are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. b) Is to be centered >30" but S44" above floor. 32. Show or note that the maximum effort to operate doors shall not exceed 8-^^ pounds for exterior doors and 5 pounds for interior doors, with such pull or push effort being applied at right angles to hinged doors and at the center plane of sliding or folding doors. When fire doors are utilized, the maximum effort to operate the door may be increased to not exceed 15 pounds. Section 1133B.2.5. 33. Show or note that the lower 10" of all doors comply with Section 1133B.2.6, as follows: a) To be smooth and uninterrupted, to allow the door to be opened by a wheelchair footrest, without creating a trap or hazardous condition. b) Narrow frame doors may use a 10" high smooth panel on the push side of the door. . SANITARY FACILITIES 34. Note that the doonways leading to sanitary facilities shall be identified, per Section 1115B.6, as follows: a) An equilateral triangle %" thick with edges 12" long and a vortex pointing upward at men's rest rooms. b) A circle %" thick, 12" in diameter at women's rest rooms. c) A 12" diameter circle with a triangle superimposed on the circle and within the 12" diameter at unisex rest rooms. d) The required symbols shall be centered on the door at a height of 60". e) Braille signage shall also be located on the wall adiacent to the latch outside of the doonways leading tothe sanitary facilities, per Section 1117B.5.1. a RESTROOM FIXTURES AND ACCESSORIES (Applies to multiple accommodation) 35. Show that accessible lavatories comply with the following, per Sections 1115B.4.3: a) >30" X 48" clear space is provided in front for fonward approach. The clear space may include knee and toe space beneath the fixture. b) When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall; The counter top is s34" maximum above the floor. c) >29" high, reducing to 27" at a point located 8" back from the front edge. d) >9" high x 30" wide and 17" deep at the bottom; Hot water pipes and drain lines are insulated. 36. Show, or note, on the plans that the accessible water closets meet the following requirements, Sec. 1115B.4.1: a) The seat is to be >17" but si 9" in height. b) The controls for flush valves shall be: Mounted on the side of the toilet area; Be s44" above the floor. 37. Show, or note, on the plans that accessible urinals meet the following requirements, per Section 1115B.4.2: a) The rim of at least one urinal shall: Project at least 14" from the wall; Be si 7" above the floor. b) The control mechanism is to be located S44" above the floor. c) >30" X 48" clear floor space is provided in front of the accessible urinal. Section 1115B.4.2. 38. Show that grab bars comply with the following, per Section 1115B.4: a) Grab bars shall be located on each side or one side and the back of the water closet stall or compartment. b) They shall be securely attached 33" above the fioor, and parallel. NOTE: Where a tank-type toilet is used which obstructs placement at 33", the grab bar may be installed as high as 36". c) Grab bars at the side shall be located: i) 15" to 16y2" (±1") from the center line ofthe water closet stool. ii) Be >42" long with the front end positioned 24" in front of the stool. iii) Total length of bars at the back shall be >36". d) The diameter, or width, ofthe grab bar gripping surface is >1Vi" but slVi", or the shape shall provide an equivalent gripping surface. e) If mounted adjacent to a wall, the space between the wall and the grab bar shall be 1 Vi\ 39. Per Section 1115B.8, show on the plans <40" height for: a) The operable parts of at least one: i) Paper towel dispenser; Sanitary napkin dispenser. ii) Waste paper disposal; Other similar dispensing and/or disposal fixtures. b) The bottom edge of mirrors. . MULTIPLE ACCOMMODATION SANITARY FACILITIES 40. Show that the accessible rest room is to be provided with a 60" minimum diameter clear space measured from the floor to a height of 27 inches. NOTE: Doors (other than the door to the accessible toilet compartment) in any position may encroach into this space by not more than 12 inches, per Section 1115B.3.1. 41. Doore sfiall not swing into the clear floor space required for any fixture witiiin ttie toilet facility. Section 1115B.3.1.2. 42. Show that at least one water closet fixture, located in a compartment, shall provide the following, per Section 1115B.3.1.4: a) >28" clear space from a fixture (or >32" clear space from a wall) at one side. b) The other side of the water closet shall provide 18" from the centeriine of the water closet to the wall. c) The compartment shall be a minimum of 60" wide. d) Clear space in front of the water closet shall be: i) >48" if the compartment has an end opening door. ii) >60" is required for side opening doors. e) Grab bars shall not project more than 3" into the clear spaces indicated. 59" MIN. AT FLOOR-MOUNTED W.C. WHEN DOOR SWINGS IN 56" MIN. AT WALL-MOUNTED W.C. WHEN DOOR SWINGS IN 54" MIN FLUSH AjnVATDR ON WIDE SIDE 60" X 60" LEVEL AND CLEAR 43. Show or note, per Section 1115B.3.1.4 that the doors to the accessible water closet compartment will be equipped with a self closing device with: a) >32" clear opening width when located at the end of the compartment. b) >34" clear opening width when located at the side of the compartment. 44. The door into the accessible water closet compartment shall be provided with a clearance of at least 18" at the strike side of the door, per Section 1115B.3.1.4.5. Additionally, such doors shall have a clear space of not less than 48" as measured at right angles to the door in its closed position. 45. If the water closet compartment has an end-opening door (facing the water closet), the door shall be located on a diagonal to the water closet, with a maximum stile width of 4 inches (see the figure below). Additionally, the door must be provided with a clearance of at least 18" at the strike side. FLUSH ACTIVATOR ON WIDE SIDE 4" MAX. ACCESSIBLE WATER CLOSET COMPARTMENT WITHIN A MULTIPLE^CCOMMODATION TOILET FACIUTY CARLSBAD 12-0737 MAY 3, 2012 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PLANCHECKNO.: 12-0737 PREPARED BY: ALI SADRE DATE: MAY 3, 2012 BUILDING ADDRESS: 1580 CANNON ROAD BUILDING OCCUPANCY: A3/B TYPE OF CONSTRUCTION: V-B BUILDING PORTION AREA ( Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) T.I. 794 Air Conditioning Fire Sprinklers TOTAL VALUE 29,473 Jurisdiction Code CB f By Ordinance I I Plan Check Fee by Ordinance ^•J Type of Review: P Complete Review $200.99 r Structural Only r" Repetitive Fee ^ Repeats r other Hourly EsGil Fee Hr. @ $173.16 Comments: Sheet 1 of 1 macvalue.doc + ^ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for Project Address: CM^Oh^ RJ) Date: ^J//^^ APN:20^-|^(^-(9(-(9O Project Description: Valuation: ENGINEERING Contact: Linda Ontiveros Phone: 760-602-2773 Email; linda.ontiveros(S)carlsbadca,gov Fax: 760-602-1052 RESIDENTIAL rENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$20,000.00) CARLSBAD COMPANY STORES PLAZA CAMINO REAL COMPLETE OFFICE BUILDING OTHER: OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BX REMARKS DATE: E-36 Notification of Engineering APPROVAL has been sent to via on Page 1 of 1 REV 4/30/11 ^ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PERMIT NUMBER CB120737 DATE 4/25/12 ADDRESS 1580 CANNON RD RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING VILLAGE FAIRE SOLAR PANELS OTHER INTERIOR TENANT IMPROVEMENT ONLY PLANNER GINA RUIZ DATE 4/25/12 p-29 Page 1 of 1 07/11 Carlsbad Fire Department BLDG. DEPT COPY Plan Review Requirements Category: TI, COMM Date of Report: 05-10-2012 Name: Address: DZN PARTNERS 682 2ND ST ENCINITAS CA 92024 Permit #: CBI20737 Job Name: LAGOON CENTER: 794 SF TI Job Address: 1580 CANNON RD CBAD Reviewed by: -7 INCOMPLETE—Tho item you havo oubmitted for review is incomplete. At thio time, thio offioo cannot— adoquatoly oonduot a ro^ao^^' to dctonnine compliance with the applicable codes and/or otondardo. Pleaae review carefully all oommonto attached. Ploaao rooubmit the necessary plans and/or Gpecifications, with changes "clouded" lu lliis ufllLC fui teview and approval. Conditions: Cond: CON0005404 [MET] APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 05/10/2012 By: df Action: AP I (4 6^ jOQ. <0 ^ 0) tV3 i _J , - .—• 1—» ON cn ro —1 I—t • 3: —' !=! ro i CJ : 70 m —I CO a m X eo o z r— ;D CO CO a m z m a: a m INAIRE -a -n -0 —1 INAIRE i— VN. -n ATI ING INAIRE ACE VN. ^ BL! 1 • 1 CO r-CD 1 • 1 AND Ml 1—< i» z AND AND Ml z —1 AND AND Ml VD! PS ] RDL EE ME z VIA —1 I—I z m VIA z X u Cl CO z r-m |— n ru o MEN 1 TING m < r-»—1 » r-DMS , HA INCA GHT • z 70 O CO o o ^ .W. |_l I—I bc4 C m Cl X —\ 3> 5" c: S CO Cl _i CO?; . -1—I CO t—I CO I . - , 3> ^ O z ^ z m p z 3^ -< z CO m m •> XJ o < 3: I—I z :n 5 a -n eo r- I T> I—t X z —• -tmi c: ' a X) o z m J-J !s (/9 ?o ^ I—I I— z Z i=3 d —I «=l CO m 3> o I— z cr m XJ * XJ r-xj m X a z o • -I z z i— I • -< CO I to < m |- ^ci z<^ z m XJ ^ Cl (-) Z I—I o f— Si •n ta I- z z I—I I—I z z I—I • z z cz c: z z XJ z m tj tr CO )—t —I INI m CO m w S m ru C/O cz z -D m ^ —I 3> XJ XJ _, I z • •ii £ cn -n I-; z S cn i» a Cl I o m XJ —< S a S ^ rn CT g XJ n pa I—I ^ •—I z z < — 3: S —' m 5 Z 3^ CO —I m _i =4 -H m XJ _( TJ "=> o 3 22 H ZTOo^op S§z^ 1-! ±i • 1» -3^2: rn xiTJ OJ c: m ^ >><rn;omz>< Parker Structural Engineering, inc. 204 N. El Cam/no Re^f #E246 Encinitas, CA 92024 760.436.1223 (phone) 760.436.1239 (fax) (>atkers^ctural@yatioo.com STRUCTURAL CALCULATiONS FOR AQUA HEDIONA LAGOON DISCOVERY CENTER T.I. 1580 CANNON ROAD CARLSBAD, CA 92008 ARCHITECT: DZN PARTNERS ARCHITECTURE JOB NO. 11140 FEBRUARY 28,2012 PLAN CHECK SUBMITTAL TABLE OF CONTENTS DESIGN CRITERIA ROOF FRAMING FOUNDATION MISCELLANEOUS I- 2 3-8 9-10 II- 12 Encinitas, CA 92024 760.436.1223 www.pafkerstructural.cMm JOB Lagoon Discovery Center Tt JOB# 11140 SHEET NO 1 OF CALCUUTED BY BP DATE 1/12 CHECKED BY REV DATE SCALE DESIGN CRITERIA CODE: 2009 International Building Code (IBC) 2010 Carrfbrnia Building Code (CBC) WOOD: 2005 NDS (2006 IBC) (N) Members: 2x, 3x, 4x >4x Douglas Fir-Larch No. 2 Douglas Fir-Larch No. 1 (E) Members 2005 NDS Equivalent: 2x, 3x, 4x Douglas Fir-Larch No. 1 >4x Douglas Fir-Larch Select Struct. SOIL: Allow, soil bearing = 4000 psf per original 1998 structural drawings S-1.0 C:\PSBProjects\Commercial\Lagoon Discovery Tl_11140\eng\Lagoon Discovery Tl Design Loads.xls 2/28/2012 Pa Encinitas, CA 92024 Phone: 760.436.1223 Fax: 760.436.1236 JOB Lagoon Discovery Center Ti X)B# 11140 SHEET NO, 2 OF CALCULATED BY BP DATE 1/12 CHECKED BY REV DATE SCALE DESIGN LOADS EXISTING ROOF DEAD LOADS fosf) Tile 10.0 3/4" PIvwood 2.3 2x10Ra. @16" 2.6 Batt Insul. 1.0 2x6 CeilinflJoists @^16" 1.6 1/2" Gyp. Ceiling 2.2 ME&P 0.5 Miscellaneous 1.3 Dead Load 21.5 Live Load 20.0 EXISTING WALLS Stucco Wood DEAD LOADS Interior Exterior Exterior Wood Siding 3.0 Stucco 10.0 Stone Cladding 1/2" Gyp 4.4 2.2 2.2 3/8" Plywood 1.1 1.1 2x4 @ 16"0.C. 1.1 1.1 1.1 Batt Insulation 0.3 0.3 Miscellaneous 0.5 0.8 0.8 Dead Load 6.0 15.5 8.5 C;\PSBProjects\Commercial\Lagoon Discovery Tl_11140\eng\Lagoon Discovery Tl Design Loads.xls 2/13/2012 3 ROOF FRAMING PLAN SCM£ Paricer Structural Engineering, inc. Encinitas, CA 92024 Phone: 760.436.1223 SHEET N0._ CALCULATED BY_ CHECKED BY SCALE OF- DATE. DATE. HA : \.Y':::r-: • ...! - - i i:; : LJ t ' Parl<er Structural Engineering, inc. Encinitas, CA 92024 Phone: 760.436.1223 JOB. SHEET NO.. CALCULATED BY_ CHECKED BY SCALE OF. DATE. DATE. top r^AHlM^ Cdf^'!> : SV^iM-^ i to" •• ••••: | • ••; :/• : ; J^^i-I^J.. {1^ ^f>^l1. ^It^ r ••: 71' A. 4^3 <rL Parser Structural Engineering, Inc. Encinitas, CA 92024 Phone: 760.436.1223 JOB_ SHEET NO.. -7 CALCULATED BY_ CHECKED BY SCALE OF. DATE. DATE. jj^,^. , ....... 3 t ^ f Parker Structural Engineering, Inc. Encinitas, CA 92024 Phone: 760.436.1223 SHEET N0._ 1 CALCULATED BY_ CHECKED BY SCALE . OF. DATE. DATE. %oDF fRAM INJ^ (fh/^^d 4 : ? ' ^^^^^^ - ^^^ ^ ^ .'I M-11^30 a^T^l*'^^: ^^^^^ (,10: .^•v.H I; ^f- "0^^ • : : : ? ? i I j .- ! etec STORASE "Tif'vs'-.rf;;. I %AdJ:: ECEPTION ; I - l\ lii ii 1 j f..lj 11 • . II ,f • lit' 5 [' MEN 1 . I Fpi N NALLI . (E) S-O' SQ. PAO fTC, TYP. OF 4 1 (E) U" WIDE PER1METE FOOHKO, TYP. r.... ^ (E) y-O' SQ. . PAD FTG. jO / MECTINS 2 \ SI FOR POST BASE * CONN TO (E) SLAB I WOMEN 2 el "iii opptce 3 \ .••5, Sj FOUNDATION PLAN SCALE; Parker Structural Engineering, Inc. Encinitas, CA 92024 Phone: 760.436.1223 SHEET NO.. 0F_ CALCULATED BY_ CHECKED BY SCALE DATE. DATE. fl CD > Cfl m • z m CO -i m Cfl r- TJ CO o OJ X o So (O OJ ro - .-^ OJ « po Co ™ to ca 5^ to •P' 00 -vl CD ~vl Ol o 01 o o 0> NJ O OY o o ooo 0> Ol Ol ooo ooo -vl ->i oo ooo 00 00 00 00 00 OJ O) CJJ CJ) OJ OJ 4:^. 4^ NJ M NJ NJ NJ NJ X X X X X X X X X X X X X X X X X X X X X X X X OS NJ ^ o 00 OJ KJ o 00 OJ NJ _k o 00 OJ .tv ro o 00 O) ->l OY Ol Ol CJJ pi CJl OJ O) OJ Ol OJ OJ Ol bl bl bl bl bl bl bl bl bl bl bl bl bl bl bl bl bl bl bl bl bl bl bl Ol OJ CO -vl —^ c;i CO CD ~>j CJI Ol GJ —4. <c KJ Ol OJ CO ^ (O NJ KJ Ol OJ Ol bl bl bl bl bl bl bl bl bl bl u OJ OJ Ol Ol bl bl OJ OJ <;i Ol bl bl o o o cb to o b CO CO b b b b b b isj OJ OJ bl CD b «x ivj OJ bl -sl CO o o o CO o o o o o o o o o o o o o O o o o ^ o O) Ol Ol 00 Ol 00 -J CJ) Ol 4i> o> Cfl OJ OJ N3 _^ _i OJ O) CJl CO N> o OJ OJ CO NJ Cfl CO NJ CO O) OJ o KJ NJ ivj io KJ to KJ KJ OJ OJ OJ OJ OJ io KJ bo bo bo bo Cfl CJl Ol CJl CJl Cfl CII Ol Cfl 00 00 00 CO 00 Cfl Cfl 00 c» CO 00 OJ NJ V to o NJ CJJ X "N to CJ) NJ o Cfl NJ \.J o -VJ OJ bo b) 00 OJ to io 00 Ol NJ to ^ b) fll r-Y ~*J -^^ Co -»• fj^ g OJ CO p ^1 L^j OJ CD -vl CJJ -b. CO to OJ -» CO CO OJ 00 Cfl w w O) TO CO Cfl to CO -sl -vJ CO tfl ro Ol CO C3) p Ol OJ bl CO ?i § to CO o to 53 CO S o 00 -J OJ Oi IO -s( CO po Cfl p »x bl OJ 00 Cfl Cfl .ti to Cfl <o g ^ 00 p ^ 00 CD CJJ 00 -"^ N m h O m 5' 3} ' w m > _ O c Cfl z m ^. T3 O •n to ->. CJJ NJ S S Ni CJ O g S 00 CO Cfl g S OJ OJ " * 00 CD OJ -J. 00 O IO -J Q i-S CO CO NJ CO g K 00 o o. - ro o CJJ M -i. - , 2 2 o *> CO -sl 2 CJJ 00 CD CD iS 3 O CD O) CJ) to to CO OJ OJ -sl OJ o -s] OJ CJJ CO IT -sl CO :^ -tv JV -» CO IO NJ -I a <? H » S CJ) .U O ~T ^ to OJ CO W '.Jf KV OJ OJ " CO Ol -1 Cfl O O O OJ 00 NJ -sl -sl .tl. K) Cfl o -»• CO CO CJJ 00 ^ CO :>! Cfl OJ NJ t3 OJ CJJ OJ -sl -1 g O ->• 4^ NJ Cfl CO NJ IO -sJ CD NJ Jv p O) O -sl ^ OJ -4 Jv CO JV IO CO 0) O) OJ to -i ... NJ Cfl 00 00 to Cfl to f? OJ CO CO 00 ^ •sJ JV OJ O to ->. 00 O Cfl -sl Cfl CO CO Jv Cfl CD Cfl to S« o> -sl O O) JV O O 00 CD JV CO ^ rn rj OY -sl CO CO CD S fee o) o CO M o S CO CO pj -V M 00 OJ o) IO o " O 00 CO Cfl O CJJ -sl 00 JV CO to -1. ^ OJ Jv O O) to -V -». JV O CJ) 00 Cfl o 00 -vl 00 00 to NJ -1 O CO -vl S CD 2 OJ -vl to A. O OJ CO O CO Jv O 00 O) JV to ro OJ ^ iS tfl CO Ol 00 o ^ O) OD -sl CO CD JV CO lo -J' -s . -A to Jv CJ) o S ->• CD Cfl CO ro O) IO NJ 00 CO OJ NJ to ->• 00 CO NJ 4V « CO CD O ^ _L -sJ JV -sj 00 o O o CO 00 1^ OY <0 (30 -V CJ) -i 2 V Cfl CO O S OY OJ CD CJ) NJ S fS -J O O -vJ ° " *i. OJ NJ -i 00 VJ S.J ^ o O) JV Cfl O) to Jv vj Cfl IO 00 -sl O) O tfl JV OJ to to Cfl VJ o OJ Jv vJ 00 -» oo NJ o o 00 JV OJ O) N) CO CD CJ) to o •J;' it 7^ S 00 -i S S m 5=; ^ 00 00 O) CO S g ^ Ol CD O ^ ^ FO to CJ) CO ->• io o ffl W Cfl CJJ g g g Ol CO -sl CJJ g § g OJ OJ Ol JV to ro -i ->. ,-, «D CD CO CD to S to tfl JV CJ) OJ CO O CO tfl tfl CJ) .tk. to to ->• -k CO CJJ JV Cfl -sl CO -vj tn JV CO oo 00 0) JV to ,j _i CD 00 CJ) 55 -s4 o CO vj -4 VJ 5} Ol Ol tfl CD a> -sl Cfl Jv CO CJJ ^ CO CJJ CJ) OJ IO vj NJ to tfl 00 to Cfl 00 CJ) JV NJ o *. OJ to o S •^ *p S CO Jv CO Jv r; o oo -4 Cfl JV K S «C -1^ °o 1^ ° 5 * O JV 00 O IO JV Cfl Vsl -sJ CD O) Cfl Jv OJ OJ to JV tfl ~J 00 O CO O CJ) NJ 00 -vl CJ) OJ tJ) CJ) 0) O O CJO OJ Cfl Jv CO to o CO CO 00 00 oo 00 O Cfl O Cfl O 00 CO -sl -vl -J vj -J 00 00 «ft m O) O CJ) CO }g J» go ro o) o S g CJ) OJ OJ tJ) " ^ IO IO to -i ^ CO Cfl O (J) NJ ^ 00 to 00 0> CO S NJ to to ro 00 o o II b O o o II NJ Cfl p IO Q T3 > o m ii p o o o o II 1. K) Cfl o o II b o o o II NJ Cfl 1 ^ o o o o II io Cfl Q JO > p m CO VY I'Z- gModemfdId' ACOUSTI-SEAL® 900 SERIES TECHNICAL DATA 1.6 WARRANTY A. Provide written warranty by manufacturer of operable partitions agreeing to repair or replace any components with manufacturing defects. B. Warranty period: Two (2) years. PART 2 - PRODUCTS 2.1 MANUFACTURERS, PRODUCTS, AND OPERATION A. Manufacturers: Subject to compliance with requirements, provide product by the following: 1. Modernfold, inc. B. Products: Subject to conipliance with the requirements, provide the following product: 1. Acousti-Seal #931 manually operated individual panel operable partition. 2.2 OPERATION A. Acousti-Seal #931: Series of individual flat panels, manually operated, top supported with operable floor seals. B. Final Closure: 1. Horizontally expanding panel edge with removable crank. 2. Hinged panel closure. 3. Enclose. 4. Pass door closure. 2.3 PANEL CONSTRUCTION A. Nominal 3-inch (76 mm) thick panels in manufacturer's standard 48-inch (1220 mm) widths. Ail panel horizontal and vertical framing members fabricated from minimum 18-gage formed steel with overlapped ancJ welded corners for rigidity. Top channel is reinforced to support suspension system components. Frame is designed so that full vertical edges of panels are of formed steel and provide concealed protection of tiie edges of the panel skin. B. Panel Skin Options: 1.1/2-inch (13 mm) tackable gypsum board, class "A" rated single material or composite layers continuously bonded to panel frame. Acoustical ratings of panels with this construction (select one): a. 41 STC b. 47 STC c. 50 STC 2.1/2-inch (13 mm) tackable moisture and mold resistant gypsum board, class "A' rated single material or composite layers continuously bonded to pane! frame. Acoustical ratings of panels vvith this construction (select one): a. 41 STC b. 47 STC c. 50 STC 3.1/2-inch (13 mm) NAUF medium density fiber- board, single material or composite layers continuously bonded to panel frame. Acoustical ratings of panels with this construction (select one): a. 41 STC b. 47 STC c. 50 STC 4. Roll-formed steel wrapping around the panel edge. Panel skins shall be lock formed and welded directly to the frame for unitized construction. Acoustical ratings of panels with this construction (select one): a. 45 STC b. 50 STC c. 52 STC C. Hinges for Closure Panels, Pass Doors, and Pocket Doors shall be (select one): 1. Full leaf butt hinges, attached directly to panel frame with welded hinge anchor plates within panel to further support hinge mounting to frame. Lifetime warranty on hinges. Hinges mounted into panel edge or vertical astragal are not acceptable. 2. SOSS® Invisible laminated hinge with antifriction segments rhounted between each heat treated link. Hinge to be attached directly to panel frame. Welded internal hinge bracket shall support the hinge and allow for adjustment of hinge piates. Concealed hinges mounted into edge or vertical astragal are not acceptable (available on steel skin panel only). •.Panel Trim: No vertical trim required or allowed on edges of panels; minimal groove appearance at panel joints. E. Panel Weights: Non-Steel Skin 1.41 STC - 6.5 Ibs./square foot 2.47 STC - 7 Ibs./square foot Steel Skin 1.45 STC-8 Ibs./square foot 2.50 STC - 8 Ibs./square foot 3. 52 STC - 11 Ibs./square foot 5' -muu r/|*4(^t Plaase contact your local Modernfold distributor for further assistance, or visit our website ai www.modernfold.com. PROJECT NAME: Lagoon Discovery Center Tl 1580 Cannon Rd., Carisbad, CA 92008 ABBOTT Engineering Job Number: 11-240 iVIECHANICAL TITLE 24 CERTIFICATION PRESCRIPTIVE APPROACH 8/15/2012 DOCUMENTATION AUTHOR Louis E. Abbott, PE ABBOTT Engineering, Inc. (760)487-1396 2145 Newcastle Ave. Cardiff By The Sea, CA 92007 CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION ENERGY CHECKLIST ENV-IC (Page lof 4) Project Name: lagoon Discovery Center Tl 8/15/2012 Climate Zone: Project Address: Conditioned Floor Area: 1580 Cannon Rd., Carlsbad, CA 92008 1,096 General Information Building Type: Nonresidential High-Rise residential Hctel/Motel Guess room Cl Schools (Public School) Relocatable Public School Bldg. ~1 Conditional Spaces LJ Unccnditional Spaces L] Skylight Area for Large Enclosed Space>8000 ft^ (If Checked include the ENV-4C with submittal) Phase of Construction: TJ New Construction ! Addition Alteration Approach of Compliance: D Component i 1 Ove-ail Envelope LJ Unconjitioned (file affidavit) I N/A I Front Orientation: N, E, S, W or in degrees: FIELD INSPECTION ENERGY CHECKLIST OPAQUE SURFACE DETAILS Tag/ ID Assembly Name' Frame type^ Furring framing •Material' Surface Area | Surface Orientation N, S, W, E Cavity R-Vaiue Continuous R-Vaiue Exterior Furring Framing R-Value' Interior Furring Framing R-Value' Conditions status' Special Feature' Pass Fail' N/A u 1 1 u u u u l.l 11 u u 1_ L.J LJ L 1. Indicate the Identifying name of the Assembly name (i.e. Wall-1, Ceiling-1, Roof-1, and Floor-1) 2. Indicate type of Assembly Type such as Wood 2x4 or LW CMU 8". For Additional other assembly type see Reference Joint Appendix, JA4-1. 3. Enter the framing material type (wood or metal) and refer to ENV-2C Furring Strips Construction Worksheet. 4. Indicate Furring R-Value when furred wall are being used. 5. Indicate status of fenestration (New, Existing or Upgrade). S.lndicate Special Feature on Page 2 ofthe Inspection Checklist Form below. 7. If Fail, then describe on Page 2 ofthe Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. FENESTRATION SURFACE DETAILS Tag/ ID' Fenestration Type' Surface Area Surface Orientation N, S, W, E |# of Panes | Max U-Factor IVlax (R)SHGC m 01 u 3 o l/l Overhang Conditions Status' Special Feature' Tag/ ID' Fenestration Type' Surface Area Surface Orientation N, S, W, E |# of Panes | Max U-Factor IVlax (R)SHGC m 01 u 3 o l/l Overhang Conditions Status' Special Feature' Pass Fail" N/A u u u 11 1 1 IJ u LJ u 1 LJ LJ L„ 1 ) . J 1, 1. Indicate the identifying name of the frame type (i.e. window #1). 2. Indicate type of construction Type such. Window, Glass Door, Curtain Wall, Skylight, or other 3. Indicate if the efficiency values are from the NFRC label Certificate of from the CEC Default Values. Enter NFRC or CEC (FC-land FC-2). 4. Indicate Status of fenestration (New, Existing or Upgrade). S.lndicate Special Feature on Page 2 of the Inspection Checklist Form below. 7. If Fail then describe on Page 2 ofthe Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. 200S Nonresidential Compliance Forms August 2009 *N0 REVISIONS TO ENVELOPE CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION ENERGY CHECKLIST ENV-IC (Page 2 of 4) Project Name: Lagoon Discovery Center Tl Date: Climate Zone 8/15/2012 ROOFING PRODUCT (COOL ROOFS) (Note if the roofing product is not CRRC certified, this compliance approach cannot be used). Go to overall Envelope Approach or Perfonnance Approach. CHECK APPUCABLE BOX BELOW IF EXEMPT FROM THE ROOFING PRODUa "COOL ROOF" REQUIREMENTS: Pass Fall' NA [ J Roofing compliance not required in Climate Zones 1 and 16 with a Low-Sloped. 2:12 pitch or less. [ j Roofing compliance not required in Climate Zones 1 with a Steep-Sloped with less than 5 ib/ft''. Greater than 2:12 pitch. J j Low-sloped Wood framed roofs in Climate Zone 3 and 5 are exempted solar relectance and thermal emittance or • ' SRI that have a U-factor of 0.039 or lower. See Opaque Surface Details roof assembly. Column H of ENV-2C. • • n ^ ^ Low-sloped Metal framed roofs in Climate Zones 3 and 5 are exempted solar relectance and thermal emittance or '—' SRI that have a U-factor of 0.048 or lower. See Opaque Surface Details roof assembly below, Column H of ENV-2C. • n • The roof area covered by buiiding integrated photovoltaic panels and building integrated solar thermal panels are — exemted solar relectance and thermal emittance or SRI. See spreadsheet calculator at wvvw.energy.ca.gov/tltle24/ • • • Roof constructions that have thermal mass over the roof membrane with a weight of at least 25 Ib/ft' is exempt from the '— Cool Roof criteria below. n n n High-rise residentiai buildings and hotels and motels with low-sloped roofs in Climate Zones 1 through 9,12 and 16 are exempted from the low-sloped roofing criteria. • 1. If Fail then describe on this page ofthe Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary CRRC Product ID Number' Roof Slope <2:12 >2:12 Product Weight <5lb/ft' >5lb/ft' Product Type' Aged Solar Reflectance' Thermal Emmitance Spedal Feature* Pass Fail' • L:J • • • • • • n • • • • n • • • • 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www.coolroofs.ore/products/search.ohp 2. Indicate the type of product is being use for the rooftop, i.e. single-ply roof, asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not avaiiable in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the same directory and use the equation (0.2+0.7(pi„iti,i-0.2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance. From the Cool Roof Rating Council's Rated Product Directory. 4. Check box if the Aged Reflectance is a calculated value using the equation above. 5. The SRI value needs to be calculated from the spreadsheet calculator at http://www.energy.ca.gov/title24/ 6. Indicate Speciai Feature on Page 2 ofthe Inspection Checklist Form below. 7. If Fail then describe in this page ofthe Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. To apply Liquid Field applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in §118(1)4. Select the applicable coating: LJ Alluminum-Plgmented Asphalt Roof Coating 1 lement-Based Roof Coating Q Other_ SPECIAL FEATURES INSPECTION CHECKLIST The local enforcement agency should pay speciai attention to the items specified in this checklist. These items requirespecial written justification and documentation, and speciai verification. The local enforcement agency determines the adequacy of the justification, and may reject a buiiding or design that othenwise complies based on the adequacy ofthe special justification and documentation submitted. Discrepancies: 2008 Nonresidential Compliance Forms August 2009 *N0 REVISIONS TO ENVELOPE CERTIFICATE OF COIVIPLIANCE ENV-1 C AND FIELD INSPECTION ENERGY CHECKLIST (Page 3 of 4) Project Name: Oate: Climate Zone: Lagoon Discovery Center Tl 8/15/2012 7 Required Acceptance Tests Designer: This form Is to be used by the designer and attached to the plans. Listed below is the acceptance test for the Envelope Fenestrations system. The designer Is required to check the acceptance tests and list all the fenestrations products that require an acceptance test. If all the site-built fenestration of a certain type requires a test, list the different fenestration products and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference Appendices IVlanual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Enforcement Agency: System Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or when ever new fenestration is installed in the building or space shall be certified as meeting the Acceptance Requirments. The ENV-2A form is not considered a complete form and is not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §10-103(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can receive final occupancy. A copy of the ENV-2A for each different fenestration product line must be provided to the owner of the building for their records. Test Description ENV-2A Test Performed By: Number Building Fenestration Products Name or ID of like Envelope Requiring Testing or Verification Products AcceptanrpTest u 1 J 1 ; 1 : LJ Li U 1 i 1 i 1 j *N0 REVISIONS TO ENVELOPE | 2008 Nonresidential Compliance Forms August 2009 CERTIFICATE OF COMPLIANCE ENV-1 C AND FIELD INSPECTION ENERGY CHECKLIST (Page 4 of 4) Project Name: Date: Climate Zone: Lagoon Discovery Center Tl 8/15/2012 7 Documentation Author's Declaration Statement • 1 certify that this Certificate of Compliance of documentation is accurate and complete. Name: Louis E. Abbott, PE Signature: Company: ABBOTT Engineering, Inc. Date: 8/15/2012 Address: 2145 Newcastle Ave. if applicable CEA# CEPE# City/State/Zip Cardiff By The Sea, CA 92007 Phone: (760) 487-1396 Principal Designer's Declaration Statement • i am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the design. • This Certificate of Compliance identifies the envelope features and performance specifications required for compliance with Title 24, Parts 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with the information provided to document this design on the other applicable compliance forms, worksheets, caicuiations, pians and specificabons submitta#Wtl«e enforcement agency for approval with this buiiding permit appiication. A \ i < f Company: , Date: . t Address: ^ _ License# ^ ^ ^ ^ 5---^ City/State/Zip j_ ^ ^ . r-> , i Phone: , > / Envelope iVIandatory Measures Indicate location on buiiding plans of Mandatory Envelope Measures Note Book: INSTRUCTIONS TO APPLICANT ENVELOPE COMPLIANCE & WORKSHEETS (Check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Compliance manual. Lj ENV-IC Certificate of Compliance and Field Inspections Energy Checklist. Required on plans for all submittals. n ENV-2C Use with the envelope Component approach. Optional on plans. ; i ENV-3C Use with the overall envelope TDV Energy Approach. Optional on plans. [ . ENV-4C Use when minimum skylight requirements for large enclosed spaces are required in climate zones 2 through 15. Optional on plans. 2008 Nonresidential Compliance Forms August 2009 *N0 REVISIONS TO ENVELOPE CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Parti of 5) MECH-1 C Project Name: Lagoon Discovery Center Tl 8/15/2012 Project Address: 1580 Cannon Rd., Carlsbad, CA 92008 Conditioned Floor Area: 1,096 General Information Building Type: [2] Nonresidential L] High-Rise Residential L] Hotel/Hotel Guest Room Schools (Public School) Relocatable Public Schocl Bldg. • Conditioned spaces L] Unconditioned Spaces Phase of Construction: LJ New Constructton Addition Approach of Comnpliance: GO Component J Overall Envelope TDV energy L] Alteration TT Unconditioned (file affidavit) Front Orientation: N, E, S, W or in Degrees: N/A HVAC SYSTEM DETAILS FIELD INSPECnOM ENERGY CHECKLIST Equipment^ Inspection Cnteria Meets Criteria or Requirements Equipment^ Inspection Cnteria Spedal Feature* Pass Fail - Described Reason^ Item or System Tags (i.e. AC-1, RTU-1, HP-1) FC/CU-IE* Ll • • Equipment Type": Split System Heat Pump U u u No of Systems 1 LJ u u Max Allowed Heating Capacity N/A U 11 u IVIinimum Heating Efficiency N/A U u u Max Allowed Cooling Capacity N/A* U u u Cooling Efficiency 13.0 SEER* 1 1 u u Duct Location/ R-Value R-8 LJ 1 1 LJ Duct Leakage Testing - If Yes, a MECH-4A must be submitted N/A • • • Economizer N/A LJ u U Thermostat YES U u u Fan Control CONSTANT U I...J Equipment' Inspection criteria FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection criteria Special Feature' Pass Fail - Described Reason^ Item or System Tags (i.e. AC-1, RTU-1, HP-1) n • • Equipment Type': u u No of Systems u u Max Allowed Heating Capacity u u Minimum Heating Efficiency 1 u Max Allowed Cooling Capacity LJ u Cooling Efficiency u u Duct Location/ R-Value u Duct Leakage Testing - If Yes, a MECH-4A must be submitted n • • Economizer [ J u LJ Thermostat u LJ Fan Control Ll LJ LJ 1. Indicate special feature DETAILS on page 2 ofthe Inspection Checklist Form. 2. If the actual installed equipnnent performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes. 3. For additional detailed discrepancy use Page 2 ofthe Inspection Checklist Form. 4. Indicate equipment Type: Gas(Pkg or. Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other *Units is existing to remain. 2008 Nonresidential Compliance Forms August 2009 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 2 of 5) MECH-1 C Project Name: Lagoon Discovery Center Tl Date: 8/15/2012 SPECIAL FEATURES INSPECTION CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification. The local enforcement agency determines the adequacy of the Justification, and may reject a building or design that othewise complies based on the adequacy ofthe speciai justification and documentation submitted. Discrepancies: 2008 Nonresidential Compliance Forms August 2009 o I X o UJ IO o n -e n Q. (0 _l o UJ X o >-o UJ z UJ z o H O UJ Q. (0 UJ u. •o c n UJ O Q. o o u. O UJ I- s UJ O 4-, O i£ ^— •a 4-.-OJ l/l i_ OJ •l™ (U l/l >- 0! x: ^ 4-1 ro 2 c D. ro O 2- - i O. V- a. o ai o-c £ .5? o a. 01 c jE ro E " m -2 « OJ. 01 — c ro QJ S .9- SZ 3 u cr 01 OJ — bO o SI ro TO ti *^ a. Q. OJ 01 ro ro OJ c ro iii ro a. QJ b 5 .>< ^ •D O c o. 01 1/1 Q. QJ Q. < QJ OJ ^ s o = ro OJ O ro QJ -C .a •D _ 01 to 01 +3 .SP' ._ E -I n. I/i '5 c D- ro 01 •a o OJ QJ •7^ = P Q U Q. ro Q_ 4_i ro ro ••-> ro i = £ .SP p. 0) k_ 4-, QJ C 01 QJ y •a § ^ s. t3 01 1- " -O ro T3 1= OJ ro 01 o S 4-1 O .a -° K °- . OJ lO JC ^ 14-OJ o 4-' i/i ro O QJ 1- .n OJ _ J2 7= E 5 OJ o 4-» W •D Ic C 4-1 ro QJ o .E <J QJ (/I 4:^ 0) „, F - ^ -s .p 3 OJ QJ E -D ._ Q. O OJ ap o oj OJ 01 OJ (J ^5 := 11 ra ° 1- £ o cu u i_ BO E s .£ ai g- c u •43 < 0 0) 1 ^ c QJ ro u 4-, 1/1 ro •. 3 °- f4 -a a QJ s < ts ro •£ Si BO -O o .E ts a; S i y <u E a E - l/l s OJ .S-BO .£ --n '.p O" U QJ OJ -Q ^ _ X ro TJ -c 01 QJ !5 " ii.i= C BO £ -5 2 QJ Q> *; -c c c +- ro 0) -E OJ OJ O Q. QJ 5" •a c O" QJ 01 T3 • • U > O U QJ MS < oi E S- £| c S m 3r c o o u _ 01 ro o * *4- QJ QJ in CO ra u E E ro J, O 1/1 c E u QJ 4_, 4_l C S 01 Q. 4-1 '5 QJ QJ C QJ - 5 o m • • o •° 1' E tO> _ 14- -S o •J 01 < +J •g 5 <D T3 b .S" -Q o' J_. *- ~ u Q- t o O 01 U BO Q) 1/1 j3 <" F _D OJ = E ro QJ JZ t Ul 3 E 2i O QJ *• s: QJ 4-1 U 4-i C 01 ro 01 c Cl c u u ra < 'ts = •4- ™ iC o E QJ -c jl "i o CJ ts •<= OJ ra c o E ro S. § QJ U "O J/1 BO O .E t 2 § 3 u -D L.-01 o I— 4-» ro Q. cQ QJ < 01 .fii -Q -s ?.E ro I 01 J= ro (J ra u ra g « -a ^ _n "2 "? OJ ra c _^ c ra 4_, — BO QJ *^ ^ ^ o; ra ^ t OJ J3 Q. Q. l/l •5 o E (U C o •a ™ ^ ^ on' oi r;; OJ c S t; BO ic= >-t % OJ S " c c c .. OJ c ra 4-» < ro ^ t "ro - Qi c 2 a. QJ 5- 5 ^ .5 a- ^ :b o Q. a; _aj E 01 o U 01 ro -c "D BO 0) - ra 'Q OJ . E °- OJ 8 K c o it ra 0 Q. "D 1/1 01 01 ; it t QJ o; Q. • O 00' c U 4^ : ZJ l/l I QJ O tl QJ _ Q. 'ts C ro .~ S BO •-i .E c -a OJ := I-ro 0; U 00 UJ C 2 i s -d a; lii 2 o ~ 3 "a- s 1/1 p ^ ,- £ w £ Ll. o 0) _QJ ^ Qi > DC & g 2 I I -? ^ S = »i E 1 ^ = = £ 5 < ^ g " £ 3 9. in 3 'C 01 o o 3 01 0) .a 00 c QJ C 3 a. E z 00 8 u UJ n Q. (0 _l o UJ X o >- tD m z UJ o UJ Q. (0 z UJ U. •o c (B Ul o z < o o u. o UJ H 3 u. UJ o > CQ •o < in X QJ OJ 9? ts < X u UJ O U £ K < 0) >. >< ts aa O >• < X u o a < CM iH X (J £ -J^ = t; 2 X QJ CU) O O Q £ c o u l/l 01 Q o o ao 3 < • • • E o u o z 00 o o CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 5 of 5) MECH-10 Project Name: Lagoon Discovery Center Tl Date; 8/15/2012 Documentation Author's Declaration Statement • 1 certify that this Certificate of Compliance of documentation is accurate and complete. Name: Louis E. Abbott, PE Signature: 0^^—--^^^^^^^^^^^^^^'^ Company: ABBOTT Engineering, Inc. Date: 8/15/2012 Address: 2145 Newcastle Ave. If applicable CEAfl CEPE# City/State/Zip Cardiff By The Sea, CA 92007 Phone: (760) 487-1396 Principal Mechanical Designer's Declaration Statement • 1 am eligible under Division 3 ofthe California Business and Professions Code to accept responsibility for the mechanical design. , • This Certificate of Compliance identifies the mechanical features and performance specifications required for compliance with Title 24, Parts 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with the this design on the other applicable compliance forms, worksheets, calculations, plans and enforcement agency for approval with this building permit application. nformation provided to document specifications submitted to the Name: Louis E. Abbott, PE Sifinatiirp: C ^-^^ Company: ABBOTT Engineering, Inc. Date: 8/15/2012 Address: 2145 Newcastle Ave. License # IVI31971 City/State/Zip Cardiff By The Sea, CA 92007 Phone: (760) 487-1396 IVIandatory Measures Indicate location on building plans of Note BlocIc for Mandatory Measures Ml.O MECHANICAL COMPLIANCE FORMS & WORKSHEETS (Check box if worksheet is included) For detailed Instructions on the use ofthis and all Energy Efficiency Standards compliance forms, refer to the 2008 Nonresidential Manual Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. Ld MECH-IC Certificate of Compliance. Required on plans for all submittals. MECH-2C Mechanical Equipment Summary is required for all submittals. MECH-3C Mechanical Ventilation and Reheat is required for all submittals with mechanical ventilation MEtH-4C Fan Power Consumption is required when tor all prescriptive submittals. 2008 Nonresidential Compliance Forms August 2009 AIR SYSTEM REQUIREMENTS (Parti of3) MECH-2C PROJECT NAME: DATE: Lagoon Discovery Center Tl 8/15/2012 Indicate Air Systems type (Central, Single Zone, Package, VAV or etc..) Item or System Tags (i.e. AC-1, RTU-1, HP-1) 'J FC/CU-1E* No. of Systems 1 Indicate Page Reference on the Plans or Schedule list or list information IKIOW MANDATORY MEASURES Heating Equipment Efficiency n2(a) N/A Cooling Equipment Efficiency 112(a) 13.0 SEER* HVAC or Heat Pump Thermostats 112(b), 112(c) YES Furnace Controls/Thermostat 112(c), 115(a) N/A Natural Ventilation 121(b) N/A IVlechanical Ventilation 121(b) SEEM1.1. VAV Minimum Position Control 121(c) N/A Demand Control Ventilation 121(c) N/A Time Control 122(e) PROG. Setback and Setup Control 122(e) N/A Outdoor Damper Control 122(f) N/A Isolation Zones 122(g) N/A Pipe Insulation 123 N/A Duct Insulation 124 R-8 PRESCRIPTIVE MEASURES Calculated Design Heating Load 144(a & b) 33.2 MBH* Calculated Design Cooling Load 144(a & b) 48.9 MBH* Fan Control 144(c) CONSTANT DP Sensor Location 144(c) N/A Supply Pressure Reset (DDC only) 144(c) N/A Simultaneous Heat/Cool 144(d) N/A Economizer 144(e) N/A Heat and Cool Air Supply Reset 144(f) N/A Electric Resistance Heating' 144(g) N/A Heat Rejection System 144(h) N/A Air Cooled Chiller Limitation 144(i) N/A Duct Leakage Sealing. If Yes, a 144(k) N/A MECH-4-A must be submitted 144(k) N/A 1. Total inslailed capacity (Mbtu/hr) of ali electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used, explain which exception(s) to §144(g) apply. *Unit is existing to be reused. 2008 Nonresidential Compliance Forms August 2009 o CM I z o Ul o n 0. Ul < Q & O . } S2 . •S "5 OQ i2 I .o g i tn lu 9 I c o 'S n u IS "5 a> a (0 0) cc o O) n Q. 5 z Vi H Z UJ S UJ o Ui UJ H (0 > (0 UJ 9 UJ I-< 0) o 0) > o u w 5 c o o O) m 2 5 8 1 * to ts (I) s & .g to g o I i S i I 8 E ® E " l/l iJ. i?r b E ^ < (0 111 (0 < (O LU Qf (0 < IU S > > o 5 £ < a Of Q 5 ^ O Z 3= o W < S lu S = •= DC * Ji 3 D. c 5 3 S E ^ l/l — oJ] 2. !n > c o m X U ra bo bo •- •- re e Q. JS Z E - II Ol — •- e E i i ° § Ol o E £ ra £ ii 5 o ? ^ £ t u u > u u > Q rsi o cs X o UJ o to t: n D. CN in O) 5 < a o I Vi UJ S UJ o UJ oe. < tL (0 IJ O o 0. 00 Oi. Ui I-< I- o X UJ o > Oi m tn c a> U £> 0) > o u in 5 c o o Ol i2 E 0) i CO UJ Q£ (0 < O 5 Q •5 ro .9i T. 01 O m X 01 = -= it .2 UJ o > a: LU CO 5 2 2 -S Si 5 ns ™ jS Q <u O .& O (0 a. TI £ .2 < OJ ^ i 0) f l-i tl 2 O) o_ Q. O O o ~ ro 2= J: * _ c O <1> o E 00 o o o CO I X o m in LU •a I z o E 3 E > X Ul S (A O S Q < UJ X UJ QC Q Z < z o z UJ > -I < o z < X o UJ c « o > o u M £1 Csl z g !5 > -J < (0 CO < CQ >-o z < Q. O O o LU o Ul s V) CO < OQ < m Qf < LU o LU —) o cn a. CO 52 ffl ^ oi l S 0£S X E CQ U c c O) o c p . "5 CD O < X fc LU > W ° D: s Q JJ « u. S 3 X U. U Ml c CL E o 3 W z 0. SLL < DQ c o n o o « 1 i 5 o <u E .C 3 I. < 11) c E •5 ° a; re Ol O O 3 < Q. E o u c •a 00 o o FAN POWER CONSUMPTION MECH-4C PROJECT NAME Lagoon Discovery Center Tl DATE: 8/15/2012 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach, See Power Consumption of fans§144(c). A B C 1 D E F FAN DESCRIPTION DESIGN BRAKE HP EFFICIENCY NUiVIBER OF FANS PEAKWATtS B X E X 746 / (CxD) FAN DESCRIPTION DESIGN BRAKE HP IVIOTOR DRIVE NUiVIBER OF FANS PEAKWATtS B X E X 746 / (CxD) N/A #DIV/0! #DIV/0! #DIV/OI #DIV/OI #DIV/0! #DIV/0! #DIV/0! Totals and Adjustments FILTER PRESSURE ADJUSTIVIENT Equation 144-A in §144(c) ofthe Energy Standards. A.) If a filter pressure drop (SPa) is greater than 1 inch W.C. or 245 Pascal then enter SPa on Line 4. Enter Total Fan pressure drop across the fan (SPf) on Line 5. B) Calculate Fan Adjustment and enter on line 6. C) Calculate Adjusted Fan Power Index and enter on Row 7 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUMN F) FILTER PRESSURE ADJUSTIVIENT Equation 144-A in §144(c) ofthe Energy Standards. A.) If a filter pressure drop (SPa) is greater than 1 inch W.C. or 245 Pascal then enter SPa on Line 4. Enter Total Fan pressure drop across the fan (SPf) on Line 5. B) Calculate Fan Adjustment and enter on line 6. C) Calculate Adjusted Fan Power Index and enter on Row 7 2) SUPPLY DESIGN AIRFLOW (CFM) FILTER PRESSURE ADJUSTIVIENT Equation 144-A in §144(c) ofthe Energy Standards. A.) If a filter pressure drop (SPa) is greater than 1 inch W.C. or 245 Pascal then enter SPa on Line 4. Enter Total Fan pressure drop across the fan (SPf) on Line 5. B) Calculate Fan Adjustment and enter on line 6. C) Calculate Adjusted Fan Power Index and enter on Row 7 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2)' FILTER PRESSURE ADJUSTIVIENT Equation 144-A in §144(c) ofthe Energy Standards. A.) If a filter pressure drop (SPa) is greater than 1 inch W.C. or 245 Pascal then enter SPa on Line 4. Enter Total Fan pressure drop across the fan (SPf) on Line 5. B) Calculate Fan Adjustment and enter on line 6. C) Calculate Adjusted Fan Power Index and enter on Row 7 4) SP, FILTER PRESSURE ADJUSTIVIENT Equation 144-A in §144(c) ofthe Energy Standards. A.) If a filter pressure drop (SPa) is greater than 1 inch W.C. or 245 Pascal then enter SPa on Line 4. Enter Total Fan pressure drop across the fan (SPf) on Line 5. B) Calculate Fan Adjustment and enter on line 6. C) Calculate Adjusted Fan Power Index and enter on Row 7 5)SP, FILTER PRESSURE ADJUSTIVIENT Equation 144-A in §144(c) ofthe Energy Standards. A.) If a filter pressure drop (SPa) is greater than 1 inch W.C. or 245 Pascal then enter SPa on Line 4. Enter Total Fan pressure drop across the fan (SPf) on Line 5. B) Calculate Fan Adjustment and enter on line 6. C) Calculate Adjusted Fan Power Index and enter on Row 7 6) Fan Adjustment = l-(Sp,-l)/SP, FILTER PRESSURE ADJUSTIVIENT Equation 144-A in §144(c) ofthe Energy Standards. A.) If a filter pressure drop (SPa) is greater than 1 inch W.C. or 245 Pascal then enter SPa on Line 4. Enter Total Fan pressure drop across the fan (SPf) on Line 5. B) Calculate Fan Adjustment and enter on line 6. C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)^ 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 w/cfm for Constant Volume systems or 1.25 w/ cfm for VAV systems. 2008 Nonresidential Compliance Forms August 2009 ^ PLUMBING, Development Services ELECTRICAL, Building Division ^ CITY OF IVIECHANICAL leSSFaratJay Avenue r^Ani CD Anv WORKSHEET 760-602-2719 V^AKLODAU B-18 wwwcarisbadcagov Project Address: Permit No.: Information provided beiow refers to work being done on the above mentioned permit oniy. TKis form must be completed and returned to the Buildinq Pivision before the permit can be issued. Building Dept. Fox: (760) 602-8558 a Number of new or relocated fixtures, traps, or floor drains „ Nevw building sewer line? l.fhl...LS;.>:?r.^(<?»..k <?.?:^.is.X Ves J No Number of new roof drains? Install/alter water line? y Number of new water heaters? (Z^ Number of new, relocated or replaced gas outlets? ^ Number of new hose bibs? I Residential Permits: New/expanded service: Number of new amps: Minor Remodel ar7i^; Ves No Commercial/industrial: p|X.-rO F-t f-Ctoc^T i O/A»>P\-t tO*^ <5^^ Tenant Improvement: Number of existing amps involved in this project: Number of new amps Invdvedin this project: New Construction: Amps per Panel: No Ol(^<./OlTS Single Phase Number of new amperes Three Phase Number of new amperes Three Phase 480 Number of new amperes Number of new furnaces, A/C, or heat pumps? (/) New or relocated duct work? Ves \/ No Number of new fireplaces? ^ Number of new exhaust fans? \ Relocate/install vent? 0 Number of new exhaust hoods? ^ Number of new boilers or compressors? Number of HP B-18 Pagel of 1 Rev. 03/09 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE _L / Business Name Business Contact Teleptione # Project Address City state Zip Code APN# Mailing Address City State Zip Code Plan File# Project Contact Teleptione # (ISO) 7gg The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTIVIENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction priorto plan submittal. Facility's Square Footage (Including proposed project): 3| *T'*I ^ Occupancy Rating: A 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materiais None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTH/IENT OF ENVIRONI\<IENTAL HEALTH - HAZARDOUS IWATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: / / Expected Date of Occupancy: / / Date Initials • CalARP Required I Date Initials (for new construction or remodeling projects) Is your business listed on the reverse side ofthis form? (check all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greaterthan 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition pennit. Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. • CalARP Exempt • CalARP Complete / Date Initials 1. YES NO • JZI • • IZf • JZ • 0 Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.orQ/info/facts/permfts.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Search the Califomia School Directory at http://www.cde.ca.qov/re/sd/ for public and private schools or contact the appropriate school district). Has a survey been performed to determine the presence of Asbestos Containing Materials? Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? Will there be demolition involving the removal of a load supporting structural member? Briefly describe business activfties: Briefly describe proposed project: I rlficlare under penalty of perjury that to the best of my knowledge and bejieithe resRonsgs^ made hsrenrafftlrueyand correct. Name of Owner or Authorized Agent Signature of Owner or Authorized Agent V-/ <?? Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: FOR OFFICIAL USE ONLY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMH' BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD A stamp in this box onlv exempts businesses fi'om completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (02/11) County of San Diego - DEH - Hazardous Materials Division ^ CITY OF CARLSBAD UNREASONABLE HARDSHIP EXCEPTION TO DISABLED ACCESS REQUIREMENTS B-30 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Project Addre55 Permit # )Z — omn Owner LISA CA^l^Jo^^ Telephone Applicant Telephone 760 - 753 it is request that the above named project be granted an exception from the accessibiiilv requirements of the 2010 California Building Code, as spedfically noted below: A. Section 11348 General Exception: Applicable to existing building where the construction cost at this tenant space over the last three years does not exceed the valuation threshold amount. The spedflc accessibility features that create a hardship may be exempted but not all the accessibility features. The area of alteration itself may not be exempted. Valuation Tlireshold Amount $136,060.00 Access Features Item Provide desalptfon t>etow Does this feature meet the latest edition of Title 247 if not, Is this feature going to be made accessible as part ofthis permit? if so, what is the cost of mal(ing feature accessible? Attach documentation 1. Path of travel to entrance No $ 1 ^ QoO, Ob 2. Entrance res $ 1 , -Zoo . oc 3. Path of travel in bldg to area of remodel res 1 — $ 4. Elevator NJ/A — $ 5. Sanitary facilities rgq $ -2.. M-oo - oo 6. Public Telephones if provided ^ r fK — % 1. Drinking Fountains if provided re s — $ 8. Other CParI<ing, signage, etc.) Spedfy res $ { ^ oo n . 1^0 ^ QOO > OD (Pleiae provide doaunentatlott. L e.. sismed contracts, for aH construction costs listed) Total cost of access features provided (A) $ Total cost of construction of this project and ali other wotV. perfonned j over the last 3 years in this tenant space (Bj •Percentage of total cost of project (20% minimum): (A-i-B) x 100% % ( . 5'^ •go ^ OOP . go Description of access features to be provided ^ (^M^-Y^ PO^XA C UJh r PATH LL// Sf^ 1 f > Alterations performed over the last three years in this tenant space. Indude in total valuation B alx>ve unless 20% of valuation of individual remodel has already been expended on access feature (provide documentation). Permit Number (-2. - ^^37 M/A Date Description Valuation 3-0^ ooo B-29 Page 1 of 2 Rev. 03/09 B. Speciflc Exceptions Do not use this portion If part A has been completed This part Is generally used for remodels exceeding the threshold amount and where Title 24 provides an exemption from specific accessibility features. Exceptions Requested P-Oo W\ 1 Nl~T o t Code Section/Exception H^gg> Total Cost of IVlaking Features Accessible Attach Documentation $ \^ ^ Ooo , OQ Description The cost of all construction contemplated Is $ 3<3 . OO O The access feature increases the cost of construction by percentage of construction cost O The impact on financial feasibility of the project, if the requested exception is not approved is The facility Is used by the generai public for the purpose of . . The foliov/ina individuals provided information listed above Archltect/'Deslgner Owner/Tenant u\SA CAt^t^O^-'^OP\^Ai,s\ Address Address state Zip signature Required yvi Date Findings and decisions of the Enforcing Offtdal / / " cTfe^ Wn-omp/idn-j k^<n7)^e^ tf^^ihm?7i ^/^/^/^y /^/^ 7^ mu/4f 4(j/»jy^DMiim t^/^/nm^ -^^ilfl^ouj/i ^0^,3^^ -h/ie. /^t^/ luesturantea Request ilranteti General Unreasonable IHardshlp Exception request is approved based on Section 11348.2.1 of the California Building Code Access features listed in part A of this form shall be provided as part of this permit. Q Specific Exception($j request is approval based on Section(s) . Ali other access features shall be provided as specified in the Califomia Building Code. Date ML InE officia Name of enforcing official - Pleaie print Signature of enfordng official s-2g Page 2 of 2 Rev. 03/09 I CA lis mm W z -I f- m (D ET n a 3 (3' (i) > s < 0.S ^50 • 09-16-2013 City of Carlsbad 1635 Faraday Av Carlsbad.CA 92008 Plan Check Revision Permit No:PCR12l09 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC #: Project Title: 1580 CANNON RDCBAD PCR 0000000000 Lot #: $0.00 Construction Type: 0 NEW LAGOON DISCOVERY: TO PLUMBING REVISIONS Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 11/27/2012 JMA 09/16/2013 09/16/2013 Applicant: BART SMITH Owner: 760-535-2464 Plan Check Revision Fee Fire Expedited Plan Review Addifional Fees $250.00 $0.00 $0.00 Total Fees: $250.00 Total Payments To Date: $250.00 Balance Due: $0.00 Inspector: FINAL APPROVAL Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reseivations, or other exactions hereafter collectively referred to as "fees/exactions," You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CiTY OF CARLSBAD PLAN CHECK REVISION APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Plan Check Revision No. VOP\ [2-' \ Origin;:ii Plan Check No. C^. - o ~l^1 Project Address 15^0 c-^Mstbrg t? n^tP H/^7/v"Z-^ Contact S^rt" S^vH, ^ h\f^ ?h 76"- 1 ' •2.^^'/- Fax "7^0 - vS-S - ^^^o Email (O^ cJl-Zr^g ^prj-^ €^/S • Contact Address. . City |=.MC^NJ)—/)C,M. Zip ^^-"-z,^ General Scope of Work C^tAK^df^ V'^iueTS to Pt^oSH TAVO)«:, is/^T^t'^- pife Si^tf-J^ CyiAr^, Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 • Elements revised: si Plans • Calculations • Soils • Energy • Other 2. Describe revisions in detail 3. List page(5) where each revision is shown 4. List revised sheets that replace existing sheets pl.l ' 5.1 1 T 5. Does this revision, in any way, alter the exterior of the project? • Yes 6. Does this revision add ANY new floor area(s)? DYes No T. Does this revision affect any fire related issues? • Yes ^ No 8. Is this a complete set? O Yes |^ No ^Signature "5^^^^^ Vv ^7>^-/(,z No 1635 Faraday Avenue, Carlsbaci, CA 92008 £h: 760-602- 2719 £ax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov EsGil Corporation In (Partnersfiip uiitfi ^o'vemmentfor (Buiding Safety DATE: 9/6/2013 • APPLICANT a<JURIS. JURISDICTION: Carlsbad • PLANREVIEWER • FILE PLANCHECKNO.: 12-737 revl (PCR12-109) SET: III PROJECT ADDRESS: 1580 Cannon Road PROJECT NAME: change water closes and water piping. I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: Bart Smith, AIA 682 Second St. Encinitas, CA 9202^ EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Bart Smith Telephone it: 760 753 2^6*1 Fax #: 760 753 0600 Date contacted: (by: ) Email4-bvsmith@dznpartners.GGm Mall Telephone Fax In Person ^ REMARKS: Make the changes showin in RED INK in the water line pian on sheet P4.1 to show the existing one inch water main outside the building is OK as is. But at outside water main connection to inside water main the water main must be V/z inch new water main. This plan change is 8 slip-sheets (a.02, a.03, a.04, P1.1, P2.1, P3.1, P4.1,& P5.1) to be replaced in the approved plan packages. Will Foss has not waived the installation ofthe urinal water stub outs. He has waived replacing the water main from the water meter to the building only. Please size and install all the water piping inside the building. By: Glen Adamek Enclosures: EsGil Corporation • GA • EJ • PC 8/29/2013 EsGil Corporation In (Partnersfiip •witfi government for (BuiCcCing Safety DATE: 8/8/2013 ajs^LlCANT • JURia^ JURISDICTION: Carlsbad a^LANREViEWER • FILE PLAN CHECK NO.: 12-737 revl (PCR12-109) SET: II PROJECT ADDRESS: 1580 Cannon Road PROJECT NAME: change water closes and water piping. I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. [~1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ^ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I ] The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Bart Smith, AIA 682 Second St. Encinitas, CA 92024 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Bart Smith Telephone #: 760-753-2464 Fax #: 760-753-0600 Date contacted: "ZTMII^ (by: ) Email: b.smith@dznpartners.com ^ Mail ^ Telephone Fax^ In Person 3 REMARKS: Plan change are 8 slip-sheets (a.02, a.03, a.04, P1.1, P2.1, P3.1, P4.1,& P5.1) to be replaced in the approved plan packages. Will Foss has not waived the installation ofthe urinal water stub outs. He has waived replacing the water main from the water meter to the building only. Please size and install all the water piping inside the building. By: Glen Adamek Enclosures: EsGil Corporation • GA • EJ • PC 9/1/2013 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 12-737 revl (PCR12-109) 8/8/2013 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 12-737 revl (PCR12-109) PROJECTADDRESS: 1580 Cannon Road DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 9/1/2013 8/8/2013 REVIEWED BY: Glen Adamek FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised pians. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? • Yes • No Carlsbad 12-737 revl (PCR12-109) 8/8/2013 . GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Dr, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering & Fire Departments until review by EsGil Corp. is complete. 2. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. PLUMBING (2010 CALIFORNIA PLUMBING CODE) 3. Please correct the new water line sizing calculations on sheet PI .1: a) Correct the total water demand for the existing plus new water demands. i) The fixture unit calculations do not include required water stub-out for waterless Urinal. (4 flush valve fixture units.) ii) The fixture unit calculations include only one of the two drinking fountains. b) Will Foss, City of Carlsbad, has waived replacing the water main from the water meter to the building only. Upsize all the water lines inside the building. The existing 1 inch water line from the public water meter to the point of connection of the new piping for the new fixtures is way undersized. The minimum size as per the revised water line sizing calculations is a 1V2 inch water main. Please correct the only 1 inch water main shown. c) The new VA inch cold water line supplying water to a new hose bib, two lavatories, and three new flush tank water closets is undersized. The minimum size as per the revised water line sizing calculations is a 1 inch water line. d) As per the revised water line sizing calculations the minimum size water line serving the required urinal stub-out is a 1% inch water line. 4. Please correct the water line sizing calculations and the water line plans. 5. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Glen Adamek at Esgil Corporation. Thank you. EsGil Corporation In (Partnersfiip ivitfi government for (BuiCding Safety DATE: 12/7/2012 OAPPLICANT JURIS?^ ; JURISDICTION: Carlsbad • PtAttl^vlEWER • FILE PLAN CHECK NO.: 12-737 revl (PCR12-109) SET: I PROJECT ADDRESS: 1580 Cannon Road PROJECT NAME: change water closes and water piping. I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ^ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ^ The applicant's copy of the check list has been sent to: Bart Smith, AIA 682 Second St. Encinitas, CA 92024 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IXI EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Bart Smith Telephone #: 760-753-2464 Fax #: 760-753-0600 Date contacted: li'^ {by: \^) Email: b.smith@.dznpartners.com t Mall Telephone Fax'^ In Person El REMARKS: Plan change are 8 slip-sheets (a.02, a.03, a.04, P1.1, P2.1, P3.1, P4.1,& P5.1) to be replaced in the approved plan packages. By: Glen Adamek Enclosures: EsGil Corporation • GA • EJ • PC 11/29/2012 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 Carlsbad 12-737 revl (PCR12-109) 12/7/2012 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 12-737 revl (PCR12-109) PROJECT ADDRESS: 1580 Cannon Road DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 11/29/2012 12/7/2012 REVIEWED BY: Glen Adamek FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? • Yes • No Carlsbad 12-737 revl (PCR12-109) 12/7/2012 • GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. Each sheet ofthe plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. PLUMBING (2010 CALIFORNIA PLUMBING CODE) 3. Please correct the new water line sizing calculations on sheet PI .1: a) Correct the total water demand for the existing plus new water demands. i) The fixture unit calculations do not include required water stub-out for waterless Urinal. (4 flush valve fixture units.) ii) The fixture unit calculations include only one of the two drinking fountains. b) The existing 1 inch water line from the public water meter to the point of connection of the new piping for the new fixtures is way undersized. The minimum size as per the revised water line sizing calculations is a VA inch water main. Please correct the only 1 inch water main shown. c) The new VA inch cold water line supplying water to a new hose bib, two lavatories, and three new flush tank water closets is undersized. The minimum size as per the revised water line sizing calculations is a 1 inch water line. d) As per the revised water line sizing calculations the minimum size water line serving the required urinal stub-out \sa IVA inch water line. 4. Please correct the water line sizing calculations and the water line plans. 5. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Glen Adamek at Esgil Corporation. Thank you. Carlsbad 12-737 revl (PCR12-109) 12/7/2012 [DO NOT PAY- THIS IS NOT AN INVOICE] JURISDICTION: Carlsbad (PCR12-109) VALUATION AND PLAN CHECK FEE PLAN CHECK NO.: 12-737 revl DATE: 12/7/2012 PREPARED BY: Glen Adamek BUILDING ADDRESS: 1580 Cannon Road BUILDING OCCUPANCY: A3/B TYPE OF CONSTRUCTION: V-B BUILDING PORTION AREA (Sq. Ft.) Valuation Multip Her Reg. Mod. VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdction Code cb By Ordinance Bldg. Permit Fee by Ordinance • Plan Check Fee by Ordinance • Type of Review: • Complete Review •Repetitive Fee ^ Repeats Based on hourly rate • Other ^ Hourlv EsGil Fee $250.00 • Structural Only $100.00 Hrs. @ $200.00 Comments: Sheet 1 of 1 macvalue.doc + Plumbing Design Review Connment Responses PROJECTTITLE: Agua Hedionda Lagoon Discovery Center Expansion PLAN CHECKER: Glen Adamek ABBOTT JOB NUMBER: 11-240 Oesign Review Comments: 3. Please correct the new water line sizing calculations of sheet Pl.l: a. Correct the total water demand for the existing plus new water demands. i. The fixture unit calculations do not include required water stub-out for waterless urinal. (4 flush valve fixture units.) Response: Water stub-out requirement for waterless urinals has been waived per Architect's correspondence with Will Foss. ii. The fixture unit calculations include only one of the two drinking fountains. Response: Fixture unit calculation revised to include both drinl<ing fountains. See sheet Pl.l. b. The existing 1 inch line from the public water meter to the point of connection of the new piping for the new fixtures is way undersized. The minimum size as per the revised water line sizing calculations is a 11/2 inch water main. Please correct the only 1 inch water main shown. Response: A 1" line can handle a total of 30 fixture units for a flush tank system based on the water pressure analysis. The total cold water fixture units required for this entire system is 22.5 fixture units. c. The new % inch cold water line supplying water to a new hose bib, two lavatories, and three new flush tank water closets is undersized. The minimum size as per the revised water line sizing calculations is a 1 inch water line. Response: Based on the water pressure analysis, a %" pipe size can handle up to 16 fixture units. The line is supplying 3 water closets, 2-lavatories, and 1 hose bib at a total of 12 fixture units. d. As per the revised water line sizing calculations the minimum size water line serving the required urinal stub-out is a 1 X inch water line. Response: Water stub-out requirement for waterless urinals has been waived per Architect's correspondence with Will Foss. 2145 Newcastle Ave, Cardiff, California 92007 • P [760] 487-1396 F [760] 487-1439 • www.abbotteng.com Agua IHedionda Lagoon Discovery Center Page 2 July 24, 2013 Please correct the water line sizing calculations and water line plans. Response: Water line sizing has been corrected. Louis Abbott, P.E. ABBOTT Engineering, inc. Desk: 760 487 1396 Fax: 760 487 1439 www.abbotteng.com 2145 Newcastle Ave, Cardiff by the Sea, California 92007 • P [760] 487-1396 F [760] 487-1439 Page 1 of 1 Bart M Smith From: "Will Foss" <WiII.Foss@carJsbadca.gov> Date: Tuesday, July 23,2013 10:43 AM To: "Bart M Smith" <b.smith@dznpartners.com> Cc: "Al Cerda" <cerda04fam@cox.net>; "Louis Abbott" <labbott@abbotteng.com> Subject: RE: CB 12-737-PCR 12-109_Agua Hedionda Lagoon Discovery Center Bart. So only item 3.b is waived. You will make the other corrections on the plans; correct? Will From: Bart M Smith [mailto:b.smith@dznpartners.com] Sent: Tuesday, July 23, 2013 9:18 AM To: Will Foss Cc: Al Cerda; Louis Abbo\t Subject: CB 12-737-PCR 12-109_Agua Hedionda Lagoon Discovery Center Will, The plumbing engineer has written a letter asking for relief from a plumbing code requirement. See attached letter and supporting documents. If the relief is granted the project can continue to use the existing 1" water supply line. If not they will have to upgrade the water supply line. The cost of upgrading the water supply line is so significant that the lagoon discovery center would be forced to abandon the bathroom upgrade project. Please review and get back to me with your analysis. Thanks! Regards, Bart Bart McRitchie Smith Architect • AIA • LEEDap Principal DZN Partners 682 2nd St • Encinitas, CA 92024 • USA p • 760-753-2464 7/29/2013 July 17,2013 Su bject: Water M eter SIzi ng Agua Hedionda Lagoon Discovery Center Code Variance Request To whom it may concern, At the existing AHLF Lagoon Discovery Center, they are proposing to add new restrooms to accommodate the guests properly. There is an existing 1" cold water line that feeds the building. Code will allow us to use the one inch water line for the proposed fixtures as long as we do not account for a future connection to the new waterless urinal. This is due to the fact that the waterless urinal will force us to use the flush valve fixture pipe sizing table. We do not anticipate having any flush valve type fixtures on this project. Section 402.3.4 ofthe California Plumbing Code States, "Where nonwater urinals are installed they shall have a water distribution line rough-in to the urinal location to allow for the installation of an approved backflow prevention device in the event of a retrofit." For this project only, may the requirement of section 402.3.4 be waived? We believe that waterless urinal technology has improved since the code was written. There should be no reason that the waterless urinal should ever have to be updated or "retrofitted". Sincerely, Louis E. Abbott, P.E., LEED® AP ABBOTT Engineering, Inc. Desk: 760 487 1396 Cell: 760 717 0680 Fax: 760 487 1439 www.abbottenq.com 2145 Newcastle Ave, Cardiff, California 92007 • P [760] 487-1396 F [760] 487-1439 • www.abbotteng.com 05-Z o CO I