Loading...
HomeMy WebLinkAbout1600 BUENA VISTA WAY; ; CB131414; Permit02-18-2014 Job Ad(dress: Permit Type: Parcel No; Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CBI 31414 Building Inspection Request Line (760) 602-2725 1600 BUENA VISTA WY CBAD RESDNTL Sub Type: RAD 1561424000 Lot#: 0 $200,000.00 Constuction Type: 5B Reference #: 0 Structure Type: 0 Bathrooms: 0 Orig PC #: KING TRUST-CONVERT 482 SF OF EXISTING GARAGE TO FAMILY ROOM, BUILD NEW 515 SF GARAGE, REMOVE 190 SF OF EXISTING HABITABLE @ 2ND STORY, ADD 100 SF TO VARIOUS AREAS OF HOME, REMODEL REMAINDER OF HOME (APPROX 3441 SF) Status: ISSUED Applied: 06/07/2013 Entered By: RMA Plan Approved: 02/18/2014 Issued: 02/18/2014 Inspect Area: Plan Check #: 543 Applicant: COHN & ASSOCIATES ATTN: GARY COHN STE 208 512 VIA DE LA VALLE 92075 858 755-7308 Owner: KING COMMUNITY TRUST STE 10-0 5120 AVENIDA ENCINAS CARLSBAD CA 92008 760 438-8850 Building Permit $1,087.62 Meter Size Add'l Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00 Plan Check $761.33 Meter Fee $0.00 Add'l Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $20.00 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PFF (4305540) $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $213.00 Renewal Fee $0.00 ELECTRICAL TOTAL $57.00 Add'l Renewal Fee $0.00 MECHANICAL TOTAL $100.89 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green BIdg Stands (SB1473) Fee $8.00 Fire Sprinkler Fees $0.00 Green BIdg Stands Plan Chk Fee $0.00 Green BIdg Stands Plan Chk Fee TOTAL PERMIT FEES $2,247.84 Total Fees: $2,247.84 Total Payments to Date $2,247.84 Balance Due: $0.00 Inspector: FINAL APPROVAL Date: . ArrKj^'VAL / Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refemed to as "fees/exactions." You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Govemment Code Section 66020(a), and file the protest and any other required infonnation with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previouslv othenyise expired. 02-18-2014 City of Carlsbad 1635 Faraday Av Carlsbad.CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW130211 Job Address: Permit Type: Parcel No: Reference #: CB#: Project Title: Applicant: GARY COHN 1600 BUENA VISTA WY CBAD SWPPP 1561424000 Lot#: CB131414 KING TRUST-ADDITION & REMODEL Owner: DIX KAREN F Status: Applied: Entered By: Issued: Inspect Area: Tier: Priority: ISSUED 06/07/2013 RMA 02/18/2014 1 M 858 755-7308 Emergency Contact: BILL KING 760-438-8850 647 STH ST HERMOSA BEACH CA 90254 SWPPP Plan Check SWPPP Inspections Additional Fees $51.00 $216.00 $0.00 TOTAL PERMIT FEES $267.00 Total Fees: $267.00 Total Payments To Date: $267.00 Balance Due: $0.00 FINAL APPROVAL DATE l'l^j^^ixmmQ,E_ SIGNATURE THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMfT ISSUANCE: PLANNING lENGINEERING BUILDING • FIRE HEALTH HAZMAT/APCD 77 CITY OF CARLSBAD Building Pennit Appiication 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax:760-602-8558 email: building@carlsbadca.gov email: Duilding@cansDaaca.gov « . , '—— / SUITE«/5f>/ICE«/UNir# ' APN ' _V Plan Check No. Est. Value (P(PD Plan Ck. Deposit 7^ ^/. -7;^ SWPPP JOBADDRESS i600^irisHwI-RodcLH.-|5b - IM'^ - CT/PR0JECT# # BEDROOMS # BATHROOMS TENANT BUSIfKSS NAME CONSTR.TYPE V-B occ. GROUP DESCRIPTION OF WORK: Inc/ude Souare Feet of Affected Areafs) Remodel of existing $0k sqft residence, total sqft of residence will beSffU sqft. EXISTING USE I 7 " ^ IPROPOSED USE ^ GAffAG'E (SF) PATIOS (SF) DECKS (SFf FIREPUCE AIR CONOmONlNG FIRESPRINKLtRS SFR SFR 515 ^ YES[7]# NOQ YEs[7]Non YES[JNO[7] FIREPUCE YEsFTlff N0| I AIR CONOmONlNG YESrTlNol I APPLICANT NAME (Primary Contact) Gary Cohn (Cohn + Assoc.) APPLICANT NAME ^Secondary Contact) ADDRESS 512 Via De La Valle Ste 208 ADDRESS crrv Solana Beach STATE CA ZIP 92075 cnY STATE ZIP PHONE 858-755-7308 FAX 858-755-5669 PHONE FAX EMAIL gary @cohn-arch.com EMAIL PROPERTYOWNER NAME CONTRACTOR BUS. NAME ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP 92^"? ^ PHONE FAX ^bo. ^& ^3o3 PHONE _, „ FAX ^ ._ EMAIL EMAIL ARCH/DESieNER NAME & ADDRESS STATE UC.# CLASS CITY BUS. UC.# (Sec. 7031.5 Business and Professions Code: Any Cily or County which requires a permit to constmct, alter, improve, demolish or repair any structure, priorto its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7(X)0 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the aiieged exemption. Any violation of Section 7031.5 by any applicant for a pennit subjects the applicant to a civil penalty of not more than five hundred doiiars ($500)). Wf O RK ERS' COMPENSATIO N Workers' Compensation Declaration: I hereby affinn under penatty ofpeijury oned the Mkiwing dedarations: SI hav« and will maintain a certificate of content to self-insure for workers' compensation as provkled by Sectkin 3700 of the Labor Code, for the peiformance of the work for whkdi this permit is Issued. I have and wiU maintain workers' compensalion, as required by Sectkxi 3700 of the L^xir Code, fbr the perfbmiance of the work for whkh this pennit is issued. My workers' compensatkxi Insurance canier and policy number are: Insurance Co. CC ''^ '"^^el-C •^^ 4^S(» CXLf <• IS ^ Policy No. Spli (oCL<S>/ 77jitfO 2- Expiration Date f-Z5»/ >/ Bsectlan need not be completed if the pemiit is for one hundred dollars ($100) or fess. Certified of Exemption: I certify that in the performance of the work for which tliis pernilt is Issued, I shall not empfoy any person in any manner so as to become subject to the Workers' Compensatkxi Laws of California. WARNING: Faikiie to secure woilcen' compensation coverage is unlawful, and shall subject an employer to crinwial penaWes and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 ofthe Labor code, interest and attomey's fees. ^eiT CONTRACTOR SIGNATURE , 5' ""^^ . RAGENT DATE 2.tf - 2-/«/ OWNER-BUILOER DECLARATION / herefcy aflftm (haf / am eimifil from (MractoTs License Law for the foUomng reason: I I I, as owner of the property or my employees with wages as their sole compensation, will do the worit and the structure is not intended or offered fbr sale (Sec. 7044, Business and Professkxis Code: The Contractor's License Law does not apply to an owner of property who buiUs or Improves thereon, and who does such work Nmself or th^ sate. If, however, the building <x improvement is sold within one year of complelion, the owner-builder will have the bunlen of proving that he dkf not buiW or improve fbr the purpose of sale). I I I. as owner of the property, am exclusively contracting with licensed contiactors to constmct the project (Sec. 7044, Business and Professkxis Code: The Contractor's Ucense Law does not apply to an owner of property who buikis or Improves thereon, and contracts for such projects with contractor(s) licensed puisuant to the Contracfor's License Law). j I I am exempt under Sectton, .Business and Professkxis Code for this reason: 1.1 personally plan to provkle the major labor and materials fbr constiuctkHi of the proposed property Improvement 2.1 (have / have not) signed an applicatkm fbr a buikiing pemiit tbr tiie proposed worft. 3.1 have contiacted with the fblkiwing peison (fimi) to provkle the proposed constmctkm (Include name address / phone / contractors' lk»nse number): 4.1 plan to provkte portfons of the work, but I have hired the folkiwing person to coordinate, supervise and provide the major worit (inchide name / addiess / phone / contractois' icense number): S. I will provkle some of the worit, but I have contracted (hired) the folfowing persons to provide the work indicated (include name / addross / phone / type of worft): ^PROPERTY OWNER SIGNATURE •AGENT DATE Is the applicant or futuro building occupant requrod to submit a business plan, acutely hazaidous matenals registration fonn or risk management and prevention program under Sectfons 25505,25533 or 25534 of the Prestey-Tanner HazanJous Substance Account Act? OYes ONo Is the applicant or future building occupant required to obtain a pemtit from the air pollution control district or air quality management district? • Yes • No Is the fecility to be constructed within 1,000 feet of the outer boundary of a school site? OYes ONo IF ANY OF THE ANSWERS ARE YES, A FiNAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPUCANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTKMI CONTROL DISTRICT 7 I tiereby affirm that there is a construction lending agency for the perfbmrance of the work this pennit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address lcertify thati have road the applk£itkm and state that the atMKeinkxmatxxi is conect and th^ I heieby authorize lepresentative of the Clly of Carisbad to enter upon the above men^^ AGAINST ALL UABILfTIES. JUDGMENTS, OSHA An OSHA pennit is requied fbr EXRRATION: Eveiy pemiit issued by the 180 days fom *« date of such pent* or if >eS'APPUCANrS SIGNATURE ANDEXPEN: over S'O' OfSdal undeTj or woik ICH MAY IN ANY WAY ACCRUE AGAINST SAID CfTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMfT. or constiuctkxi of sfeuctunes over 3 sfories n heigit 'of Ihis Code shall expie by Imitalkxi and become nul and vokl if the buiUjng or worit aulhori is suspended or abandoned at any tine afler the vnik Is oommenoed far a period of 180 days (SecSon 1064 DATE Inspection List Permit*: CB131414 Type: RESDNTL RAD KING TRUST-CONVERT 482 SF OF EXISTING GARAGE TO FAMILY ROOM, B Date Inspection Item Inspector Act 10/28/2014 19 Final Structural -Rl 10/28/2014 89 Final Combo PY AP 10/28/2014 89 Final Combo PY CO 10/21/2014 39 Final Electrical PY PA 10/21/2014 39 Final Electrical PY PA 09/04/2014 23 Gas/Test/Repairs PY AP 08/27/2014 18 Exterior Lath/Drywall PY AP 08/08/2014 17 Interior Lath/Drywall PB AP 07/29/2014 84 Rough Combo PY AP 07/28/2014 84 Rough Combo PY PA 06/05/2014 13 Shear Panels/HD's PY AP 06/05/2014 15 Roof/Reroof PY AP 03/26/2014 11 Ftg/Foundation/Piers PY AP Comments Wednesday, November 05, 2014 Page 1 of 1 Inspection Report Project Name: r- tJ Page:. of Report #:_ Project Address: ^ U C t. /^i^ j »" / j Architect: Engineer: Permit #:£_ File #: •J Coritractor: 5 • DSA#:. Other: INSPECTION MATERIAL SAMPLING Structural Steel H.S. Bolts Masonry Prisms Concrete Mortar/Grout Fireproofins Cone. Cylinders '''^Doxy Fireproof Other: Other: Other: Other- Other: Other: Other: Other: QTY MATERIAL DESCRIPTION INSPECTION CHECKLIST H.S. Bolts Cone. PSI Grout PSI X Mortar PSI <^ Steel Elect/Wire Fireproof Other: X '/^ Other: ^1/^ / 3^ " jig'^Plans/Spees Clearances Positions . .«»^ Sizes ^nsolidation * Ttirque Ft Lbs: Other: Other: r A A) //' -•L0../^<H-i —— CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control. I hereby certify that I have observed to the best of my knowledge all of the above reported wbrk unless otherwise noted. I have found this work to comnll' with the apppayed^lans, specifications, and applicable sections of the goveming building laws. f t ing laws. ^ ^ / / Signature Date i Insp. Date: i Time Stare Day I: Day 2: IDay 3: \ Day 4: iDay 5: \ Time Stop: Approved By:. Project Superintendent EsGil Corporation In PartnersHip witH government for (BuiCding Safety DATE: 11/13/2013 • APPLICANT a^juRis. JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLANCHECKNO.: 13-1414 SET: II PROJECT ADDRESS: 1600 Buena Vista Way PROJECT NAME: King Residence Remodel 8B Addition XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. F] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. [~1 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: Gary Cohn EsGil Corporation staff did not advise the applicant that the plan check has been completed. i I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Gary Cohn Telephone #: 858-755-7308 Date contacted: (by: ) Email: gary@cohn-arch.com Fax #: Mail Telephone Fax In Person • REMARKS: By: ALI SADRE, S.E. (FOR D.Y.) Enclosures: EsGil Corporation • GA • EJ • PC 11/13 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 1 EsGil Corporation In PartnersHip witH government for (BuiCding Safety DATE: 6/19/2013 •/.PPLICANT ^ JURIS. JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLANCHECKNO.: 13-1414 SET: I PROJECT ADDRESS: 1600 Buena Vista Way PROJECT NAME: King Residence Remodel & Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. • The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Gary Cohn I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IX EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Gary Cohn Telephone #: 858-755-7308 Date contacted: Email: gary(gcohn-arch.com Fax #: ^^Mail /T.elephorte Fax In Person • REMARKS: By: David Yao Enclosures: EsGil Corporation • GA • EJ • PC 6/11 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 City ofCarlsbad 13-1414 6/19/2013 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLANCHECKNO.: 13-1414 JURISDICTION: City ofCarlsbad PROJECT ADDRESS: 1600 Buena Vista Way FLOOR AREA: Add new living 923 sf New garage 515 sf STORIES: 2 HEIGHT: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE PLANS RECEIVED BY ESGIL CORPORATION: 6/11 DATE INITIAL PLAN REVIEW COMPLETED: 6/19/2013 PLANREVIEWER: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2010 edition ofthe California Code of Regulations (Title 24), which adopts the following model codes: 2009 IRC, 2009 IBC, 2009 UPC, 2009 UMC and 2008 NEC. The above regulations apply, regardless ofthe code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copv) vyhere each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. City ofCarlsbad 13-1414 6/19/2013 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Window schedule on sheet A7 shows two L window and no T window. Please revise the window schedule. 2. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4 (see exceptions): a) Glazing in doors. b) Glazing in the walls/doors surrounding hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers where the bottom exposed edge of the glazing is less than 60 inches above the standing surface.(window L and M at master bath) 3. Guards (Section R312): a) Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". b) Shall be detailed to show capability to resist a concentrated load of 200 pounds in any direction along the top rail. Table R301.5. 4. Specify minimum % inch per foot roof slope for drainage. Section R905.9.1 and ICC report.(C for note 22 on sheet A2.1 shows 1/8" per foot.) 5. Show a self-closing door, either 1-3/8" solid core or a listed 20 minute assembly, for openings between garage and dwelling. Section R302.5.1. 6. Provide calculation to show the 51/4x117/8 and 51/4x91/2 header at master bedroom and entry at upper roof framing is adequate. City of Carlsbad 13-1414 6/19/2013 7. Provide calculation to show the roof framing above the deck outside master bedroom is adequate. 8. Provide calculation to show the roof framing for new porch outside dining is adequate. 9. Note that passageway to the mechanical equipment in the attic shall be unobstructed, have continuous solid flooring not less than 24 inches wide, and be not more than 20 feet in length from the access opening to the appliance. CMC Section 904.11. 10. Specify on the plans the following information for the fireplace(s): a) Manufacturer's name and model number, ICC approval number, or equal. b) Note on the plans that approved spark arrestors shall be installed on all chimneys. CBC Section 2802.1. c) Decorative shrouds shall not be installed at the termination of chimneys for factory-built fireplaces, except where such shrouds are listed and labeled for use with the specific system and installed in accordance with the manufacturer's installation instructions. Section Rl 004.3. 11. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52(A). 12. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(B): Family, living, bedrooms, dining, halls, etc. c) GFCI protected outlets for locations described in NEC 210.8: Kitchen, outdoors. 13. A balcony, deck, or porch that is greater in area than 20 square feet and is accessible from the interior ofthe dwelling will require a minimum of one receptacle outlet. CEC 210.52(E). This receptacle must be GFCI protected. 14. Per CEC Article 210.11(C)3, note on the plans that bathroom circuiting shall be either: a) A 20 ampere circuit dedicated to each bathroom, or b) At least one 20 ampere circuit supplying only bathroom receptacle outlets. 15. Dimension on the plans the 30" clear width required for the water closet compartment and the 24" clearance required in front ofthe water closet. CPC 407.5. City of Carlsbad 13-1414 6/19/2013 16. Provide a note on the plans: The control valves in bathtubs, whirlpool bathtubs, showers and tub-shower combinations must be pressure balanced or thermostatic mixing valves. CPC Section 414.5 and 418.0. 17. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, lavatories and kitchen faucets may not exceed 2.2 GPM, and showers may not exceed 2.5 GPM of flow. CPC Section 402.0. 18. Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement): a) In the kitchen at least one-half of the wattage rating of the fixtures must be high efficacy with non-high efficacy fixtures switched separately. Note: Approximately % of the fixtures will be reauired to be of the high efficacv variety. Note: Generally a high efficacy style of fixture is fluorescent, complete with electronic ballasts. Regular incandescent, quartz halogen and halogen MR lamps do not comply. 19. Specify on the plans: "The return air plenum serving the mechanical equipment must be fully ducted from the equipment to the conditioned space. Drop ceilings, wall cavities and equipment platforms may not be used as plenums." 20. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 21. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • 22. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at EsGil Corporation. Thank you. City of Carlsbad 13-1414 6/19/2013 [DO NOT PAY- THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLANCHECKNO.: 13-1414 PREPARED BY: David Yao DATE: 6/19/2013 BUILDING ADDRESS: 1600 Buena Vista Way BUILDING OCCUPANCY: R3/U TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA ( Sq. FL) Valuation Multiplier Reg. Mod. VALUE ($) add 923 garage 515 per city 200,000 Air Conditioning Fire Sprinklers TOTAL VALUE 200,000 Jurisdiction Code cb By Ordinance BIdg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: _J~1 Repetitive Fee ^ Repeats • Complete Review • Other |—I Hourly EsGil Fee • Structural Only Hr. @ $1,087.62 $706.95 $609.07 Comments: Sheet 1 of 1 macvalue.doc + PLAN CHECK PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 FaradayAvenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 w/w/w.carlsbadca.gov DATE: 2/13/14 PROJECT NAIVIE: KING PROPERTY (FORMERLY DIX MINOR SUB) PROJECT ID:MS 13-02 PLAN CHECK NO: CB131414 SET#: ill ADDRESS: 1600 BUENA VISTA WY APN: 156-142-40-00 VALUATION: $200,000 SCOPE OF WORK: REMODEL AND EXPANSION OF EXISTING SINGLE FAMILY HOME X This plan check review is complete and has been approved by the Land Development Engineering division. A Final Inspection by the Construction IVIanagement & Inspection Division is required: Yes No To determine status by a division not marked below, please call 760-602-2719. This plan check review is NOTCOMPLETE. Items missing or incorrect are listed on the attached checklist with the symbol X . Please resubmit amended plans as required. Plan Check Comments have been sent to: gary@cohn arch.com PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 i./ : . . , . . _ ..f .... ; ,^ ... \/ Linda Ontiveros /\ 760-602-2773 Linda.Ontiveros@carlsbadca.gov Cindy Wong 760'€i(}2'-4662 Cynthia.Wosig«it;arlsbaclca,go\' Dominic Fieri 76(>60?>4664 Domhiic.Fleriacartebadca.gov Remarks: Per discussion with Senior engineer, Jason Geldert - once security is accepted for improvement plan, DWG 479-3 -- okay to release. KING PROPERTY (FORMERLY DIX MINOR SUB) PUN CHECK NO # CB131414 Please Read lnstruc$ic^st Outstanding issues are marked with X • Once necessory corrections for compUance are made, re-submit to the Building division. Items that conform to permit requirements are marked with / or have intentionaliy been left blank. **Securlty** accepted OK TO RELEASE 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: North arrow Existing & proposed structures Existing street improvements Property lines (show all dimensions) Easements Right-of-way width & adjacent streets X Driveway widths Existing or proposed sewer lateral Existing or proposed water service Submit on signed approved plans: DWG No. 479-3 Show on site plan: Drainage patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". Existing & proposed slopes and topography Size, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. Sewer and water laterals should not be located within proposed dhveways, per standards. Include on title sheet: / Site address • Assessor's parcel number / Legal description/lot number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show all existinq use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No.: IV12169 Subdivision/Tract: (Wilsonia Tract) Reference No(s): E-36 Page 2 of 6 REV 6/01/12 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB131414 2. DISCRETIONARY APPROVAL COMPLIANCE Project does not comply with the following engineering conditions of approval for project no. **PR 13-41** 3- DEDICATION REQUIREMENTS Dedication for all street rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 20,000.00 , pursuant to Carlsbad Municipal Code Section 18.40.030. For single family residence, easement dedication will be completed by the City of Carlsbad, cost $605.00. / Dedication required as follows: James Drive shall be dedicated by Owner along the project frontage based on a center line to right of-way width of 28 feet and in conformance with City of Carlsbad Standards. Arland Road and Buena Vista Way shall be dedicated by Owner along the project frontage based on a center line to right of-way width of 30 feet and in conformance with City of Carlsbad Standards. 4. IMPROVEMENT REQUIREMENTS **DWG 479-3** / All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $100,000.00, pursuant to Carlsbad Municipal Code Section 18.40.040. / Public improvements required, but not limited to: Construction of concrete curb and gutter and 5' concrete sidewalk along James Drive, with transitional improvements at Buena Vista Drive as generally shown on the Tentative IVIap, IV1S 13-02. Completion ofthe cross gutter and installation ofa pedestrian ramp at the intersection of James Drive and Buena Vista Way. Removal of existing AC berm and widening of James Drive to 18 feet from centerline to curb face Property owner to enter into a Neighborhood Improvement Agreement with the City for the future public improvement of Arland Road along the subdivision frontage for a half street width of 30 feet. E-36 Page 3 of 6 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB131414 5. GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. / Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" Grading Permit required. NOTE: The qrading permit must be issued and rouqh qradinq approval obtained prior to issuance of a buildinq permit. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector . The inspector will then provide the engineering counter with a release for the building permit No grading permit required. Minor Grading Permit required. See attached marked-up submittal checklist for project- specific requirements. 6. MISCELLANEOUS PERMITS / RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into pubiic storm drain, sewer and water utilities. Right-of-way permit required for: E-36 Page 4 of 6 REV 6/01/12 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB131414 7. STORM WATER Construction Compliance Project Threat Assessment Form complete. Enclosed Project Threat Assessment Form incomplete. **SW13-286*'^ IN PROCESS WITH CIVIL PLAN CHECK REVIEW Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form and return (SW ) Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSIVIP) Compliance Storm Water Standards Questionnaire complete. Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign the questionnaire and resubmit with next submittal. Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Pian (SUSMP) for reference. http://www.carlsbadca.qov/business/buildinq/Documents/EnqStandsw-stds-vDl4-ch2.pdf Project needs to incorporate low impact development strategies throughout in one or more of the following ways: Rainwater harvesting (rain barrels or cistern) Vegetated Roof Bio-retentions cell/rain garden Pervious pavement/pavers Flow-through planter/vegetated or rock drip line Vegetated swales or rock infiltration swales Downspouts disconnect and discharge over landscape Other: E-36 Page 5 of 6 REV 6/01/12 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO » CB131414 8. WATER METER REVIEW FY! Domestic (potable) Use What size meter is required? Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. For residential units the minimum size meter shall be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger than one quarter (1/4) acre where the meter size shall be FY! 9. FEES Required fees have been entered in building permit Drainage fee applicable Added square feet Added square footage in last two years? Permit No. Permit No. Project built after 1980 Impervious surface > 50% Impact unconstructed facility Fire sprinklers required yes Upgrade yes No fees required yes yes yes yes no no no no no (is addition over 150' from center line) no 10. Additional Comments Attachments: Engineering Application Storm Water Form RIght-of-Way Applicatlon/lnfo. / Reference Documents E-36 Page 6 of 6 REV 6/01/12 *** Fee Calculation Worksheet *** ENGINEERING DIVISION Prepared by: Date: GEO DATA: LFMZ: / B&T: Address: BIdg. Permit #: Fees Update by: Date: Fees Update by: Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units EDU's Types of Use: Sq.Ft./Units EDU's Types of Use: Sq.Ft./Units EDU's Types of Use: Sq.Ft./Units EDU's ADT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units ADT's Types of Use: Sq.Ft./Units ADT's Types of Use: Sq.Ft./Units ADTs Types of Use: Sq.Ft./Units ADT's FEES REQUIRED: Within CFD: YES (no bridge & thorougtifare fee in District #1, reduces Traffic Impact Fee) NO 1. PARK-IN-LIEU FEE: NWQUADRANT NE QUADRANT SE QUADRANT ;W QUADRANT ADT'S/UNITS: X FEE/ADT: =$ 2.TRAFFIC IMPACT FEE: ADTS/UNITS: X FEE/ADT: =$ 3. BRIDGE & THOROUGHFARE FEE: DIST#1 DIST.#2 DIST.#3 (USE SANDAG)ADT'S/UNITS X FEE/ADT: =$ 4. FACILITIES MANAGEMENT FEE ZONE: ADT'S/UNITS: X FEE/SQ.FT./UNIT: =$ 5. SEWER FEE EDU's X FEE/EDU: =$ BENEFIT AREA: EDU's X FEE/EDU: =$ 6. DRAINAGE FEES PLDA: HIGH MED UM LOW ACRES: X FEE/AC: =$ 7. POTABLE WATER FEES: UNITS CODE CONN. FEE METER FEE SDCWA FEE TOTAL ***TMs may not represent a comprehensive list of fees due for this project. Please contact the Building division at (760] 602-2719 for a complete listing of fees*** ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carisbadca.gov PROJECTID:MS 13 02 APN: 156-142-40-00 SCOPE OF WORK: REMODEL AND EXPANSION OF EXISTING SINGLE FAMILY HOME DATE: 11/19/2013 PROJECT NAME: KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO: CB131414 SET#^ ADDRESS: 1600 BUENA VISTA WY VALUATION: $200,000 This plan check review is complete and has been approved by the Land Development Engineering division. A Final Inspection by the Construction IVIanagement & Inspection Division Is required: Yes No To determine status by a division not marked below, please call 760-602-2719. X This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist with the symbol X . Please resubmit amended plans as required. Plan Check Comments have been sent to:gary@cohn-arch.com PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 |\/] Linda Ontiveros IAJ 760-602-2773 Linda.Ontiveros@carlsbadca.gov Remarl<s: KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB1314X4 ***STOP*** Please Read Instructions: Outstanding issues are marked with X • Once necessary corrections for compliance are made, re-submit to the Building division. Items thot conform to permit requirements are marked with / or have intentionally been left blank. **CIV[L PLANS** CURRENTLY IN PROCESS ************** 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: North arrow Existing & proposed structures Existing street improvements Property lines (show all dimensions) Easements Right-of-way width & adjacent streets X ; Driveway widths Existing or proposed sewer lateral : Existing or proposed water service Submit on signed approved plans: DWG No. 479-3 Show on site plan: Drainage patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". ; Existing & proposed slopes and topography :Size, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. : Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: / Site address / Assessor's parcel number / Legal description/lot number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show all existinq use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No.: IV12169 Subdivision/Tract: (Wilsonia Tract) Reference No(s): E-36 Page 2 of 6 REV 6/01/12 KING PROPERTY (FORMERLY DIX MINOR SUBj PLAN CHECK NO # CB131414 2. DISCRETIONARY APPROVAL COMPLIANCE Project does not comply with the following engineering conditions of approval for project no. **PR 13-41** ^ IN PROCESS X 3. DEDICATION REQUIREMENTS Dedication for all street rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 20,000.00 , pursuant to Carlsbad Municipal Code Section 18.40.030. For single family residence, easement dedication will be completed by the City of Carlsbad, j cost $605.00. Dedication required as follows: James Drive shall be dedicated by Owner along the project frontage based on a center line to right of-way width of 28 feet and in conformance with City of Carlsbad Standards. Arland Road and Buena Vista Way shall be dedicated by Owner along the project frontage based on a center line to right of-way width of 30 feet and in conformance with City of Carlsbad Standards. 4. IMPROVEMENT REQUIREMENTS **DWG 479-3** X IN PROCESS ***********%** X All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $100.000.00. pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required, but not limited to: Construction of concrete curb and gutter and 5' concrete sidewalk along James Drive, with transitional improvements at Buena Vista Drive as generally shown on the Tentative Map, MS 13-02. Completion of the cross gutter and installation of a pedestrian ramp at the intersection of James Drive and Buena Vista Way. Removal of existing AC berm and widening of James Drive to 18 feet from centerline to curb face Property owner to enter into a Neighborhood Improvement Agreement with the City for the future public improvement of Arland Road along the subdivision frontage for a half street width of 30 feet. E-36 Page 3 of 6 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB13X414 5. GRADING PERMIT REQUIREMENTS **FYI** DISCUSSIONS OF X POSSIBLE STOCKPILE ***************** The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" Grading Permit required. NOTE: The qradinq permit must be issued and rouqh qradinq approval obtained prior to issuance of a buildinq permit. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector . The inspector will then provide the engineering counter with a release for the building permit. No grading permit required. Minor Grading Permit required. See attached marked-up submittal checklist for project- specific requirements. 6. MISCELLANEOUS PERMITS / RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-way permit required for: E-36 Page 4 of 6 REV 6/01/12 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB131414 7. STORM WATER Construction Compliance Project Threat Assessment Form complete. Enclosed Project Threat Assessment Form incomplete. **SW13-286** IN PROCESS WITH CIVIL PLAN CHECK REVIEW **************** Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form and return (SW ) Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSMP) Compliance Storm Water Standards Questionnaire complete. ; Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign the questionnaire and resubmit with next submittal. Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. http://www.carlsbadca.qov/business/buildinq/Documents/EnqStandsw-stds-vol4-ch2.pdf Project needs to incorporate low impact development strategies throughout in one or more of the following ways: ^ Rainwater harvesting (rain barrels or cistern) Vegetated Roof Bio-retentions cell/rain garden Pervious pavement/pavers Flow-through planter/vegetated or rock drip line Vegetated swales or rock infiltration swales Downspouts disconnect and discharge over landscape Other: E-36 Page 5 of 6 REV 6/01/12 KING PROPERTY (FORMERLY DIX IVIINOR SUB) PLAN CHECK NO # CB131414 8. WATER METER REVIEW Domestic (potable) Use / What size meter is required? FYI Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. FYI For residential units the minimum size meter shall be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger than one quarter (1/4) acre where the meter size shall be 9. FEES Required fees have been entered in building permit. Drainage fee applicable Added square feet Added square footage in last two years? Permit No. Permit No. Project built after 1980 Impervious surface > 50% Impact unconstructed facility Fire sprinklers required yes Upgrade yes No fees required yes yes yes yes no no no no no (Is addition over 150' from center line) no 10, Additional Comments Attachments: Engineering Application Storni Water Form Right-of-Way Application/Info. / Reference Documents E-36 Page 6 of 6 REV 6/01/12 CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community 8i Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carisbadca.gov DATE: 6/24/2013 PROJECT NAME: KING PROPERTY (FOR/^ERLY DIX /vAINOR SUB) PROJECT ID:MS 13-02 PLAN CHECK NO: CB131414 SET#: ! ADDRESS: 1600 BUENA ViSTA WY APN: 156-142-40-00 VALUATION: $200,000 SCOPE OF WORK: REMODEL AND EXPANSION OF EXISTING SINGLE FAMILY HOME ^ You may have corrections from one or more of the divisions listed in the table below. To determine status by one or more of these divisions, please contact 760-602-2719. This plan check review is complete and has been APPROVED by: LAND DEVELOPIVIENT ENGINEERING DIVISION A Final Inspection by the Construction Mgmt & inspection Division is required Yes No X This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist with the symbol X • Please resubmit amended plans as required. Plan Check Comments have been sent to: GARY@COHN ARCH.COM PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 \/ Linda Ontiveros /\ 760-602-2773 Linda.Ontiveros@carlsbadca.gov Remarks: ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 FaradayAvenue Carlsbad CA 92008 www.carisbadca.gov DATE: 6/24/2013 PROJECT NAME: KING PROPERTY (FORMERLY DIX MINOR SUB) PROJECT ID:MS 13-02 PLAN CHECK NO: CBI 31414 SET#: I ADDRESS: 1600 BUENA VISTA WY APN: 156-142-40-00 VALUATION: $200,000 SCOPE OF WORK: REMODEL AND EXPANSION OF EXISTING SINGLE FAMILY HOME This plan check review is complete and has been APPROVED by: LAND DEVELOPMENT ENGINEERING DIVISION A Final Inspection by the Construction IVIanagement & Inspection Division is required: Yes No To determine status by a division not marked below, please call 760-602-2719. X This plan check review is NOT COIVIPLETE. Items missing or incorrect are listed on the attached checklist with the symbol X . Please resubmit amended plans as required. Plan Check Comments have been sent to:GARY@COHN-ARCH.COM PLANNING 760-602-4610 ENGINEERING 760.602-2750 FIRE PREVENTION 760-602-4665 idca.gov ^, Kalhleen ' " • ...•"ca.gov 76CV602-466,3 Gregory J5yan(?)caiisbacJca.gov 760-602-4675 j G i il a. R Lli Z'@ c a r Ls b a d c a, g 0 V ' Linda Ontiveros |/X| 760-602-2773 Linda.Ontiveros@carlsbadca.gov Cindy Wong 760-602^4662 Cynthia.WoiigQcailsbadca.gov D c Fieri F3omiriic.Fieri@car!sbadca,gov Remarks: KING PROPERTY (FORMERLY DIX IVIINOR SUB) PLAN CHECK NO # CB1314X4 ***STOP*** Please Read Instructions: Outstanding issues ore marked with X • Once necessory corrections for compliance ore made, re-submit to the Building division. Items that conform to permit requirements are marked with / or have intentionally been left blank. SEE 10. "ADDITIONAL COMIVIENTS" 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: X X X X North arrow Existing & proposed structures Existing street improvements Property lines (show/ all dimensions) Easements Right-of-way width & adjacent streets X X X Driveway widths Existing or proposed sewer lateral Existing or proposed water service Submit on signed approved plans: DWG No. XXX-X Show on site plan: X X X Drainage patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". Existing & proposed slopes and topography Size, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: X Site address Assessor's parcel number Legal description/lot number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show all existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/IVlap No.: Subdivision/TracL Reference No(s): E-36 Page 2 of 6 REV 6/01/12 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB131414 2. DISCRETIONARY APPROVAL COMPLIANCE X Project does not comply with the foilowing engineering conditions of approval for project no. MS 13-02, Status: INCOMPLETE 3. DEDICATION REQUIREMENTS Dedication for all street rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 20,000.00 , pursuant to Carlsbad Municipal Code Section 18.40.030. For single family residence, easement dedication will be completed by the City of Carlsbad, cost $605.00. X X Dedication required as follows: James Drive shall be dedicated by Owner along the project frontage based on a center line to right of-way width of 28 feet and In conformance with City of Carlsbad Standards. Arland Road and Buena Vista Way shall be dedicated by Owner along the praject frontage based on a center line to right of-way width of 30 feet and in conformance with City of Carlsbad Standards. ** Download engineering submittal checklist, E-5 ** 4. IMPROVEMENT REQUIREMENTS X; All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $100,000.00, pursuant to Carisbad IVIunicipal Code Section 18.40.040. X Public improvements required, but not limited to: Construction of concrete curb and gutter and 5' concrete sidewalk along James Drive, with transitional improvements at Buena Vista Drive as generally shown on the Tentative Map, MS 13-02. Completion ofthe cross gutter and installation of a pedestrian ramp at the intersection of James Drive and Buena Vista Way. Removal of existing AC berm and widening of James Drive to 18 feet from centerline to curb face Property owner to enter into a Neighborhood Improvement Agreement with the City for the future public improvement of Arland Road along the subdivision frontage for a half street width of 30 feet. ** Download engineering submittal checklist, E-9 ** E-36 Page 3 of 6 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB131414 5. GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. X Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans, if no grading is proposed write: "NO GRADING" Grading Permit required. NOTE: The grading permit must be issued and rouqh qradinq approval obtained prior to issuance of a buildinq permit Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Gonstruction Inspector . The inspector will then provide the engineering counter with a release for the building permit No grading permit required. Minor Grading Permit required. See attached marked-up submittal checklist for project- specific requirements. 6. MISCELLANEOUS PERMITS X RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into pubiic storm drain, sewer and water utilities. Right-of-way permit required for: E-36 Page 4 of 6 REV 6/01/12 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB131414 7. STORM WATER Construction Compliance Project Threat Assessment Form complete. ' Enclosed Project Threat Assessment Form incomplete. Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form and return (SW ) This section to be reviewed after submittal of Improvement plans and dedication documents Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSMP) Compliance Storm Water Standards Questionnaire complete. Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign the questionnaire and resubmit with next submittal. Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. http://www.carlsbadca.qov/business/building/Documents/EngStandsw-stds-vol4-ch2.pdf Project needs to incorporate low impact development strategies throughout in one or more of the following ways: ' Rainwater harvesting (rain barrels or cistern) Vegetated Roof Bio-retentions cell/rain garden Pervious pavement/pavers Flow-through planter/vegetated or rock drip line Vegetated swales or rock infiltration swales Downspouts disconnect and discharge over landscape Other: E-36 Page 5 of 6 REV 6/01/12 KING PROPERTY (FORMERLY DIX MINOR SUB) PLAN CHECK NO # CB131414 8. WATER METER REVIEW Domestic (potable) Use / What size meter is required? FYI FYI Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. For residential units the minimum size meter shall be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger than one quarter (1/4) acre where the meter size shall be %". 9. FEES Required fees have been entered in building permiL Drainage fee applicable Added square feet Added square footage in last two years? Permit No. Permit No. Project built after 1980 Impervious surface > 50% Impact unconstructed facility Fire sprinklers required yes Upgrade yes No fees required yes yes yes yes no no no no no (is addition over 150' from center line) no 10. Additional Comments a) The property lines depicted on the plans assume completion of the parcel map. The tentative map is still in process and should not show the assumed property lines of parcels 1-4. b) Plot stopping and intersection vertical and horizontal sight distance for the driveway c) Tentative map attached for reference. Attachments: Engineering Application Storm Water Form Right-of-Way Application/Info. / Reference Documents E-36 Page 6 of 6 REV 6/01/12 CITY OF CARLSBAD STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP £-29 Development Services Land Deveiopment Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov STORM WATER COMPUANCE CERTIRCATE My project is not in a categoty of permft types exetnpt from the Corstmction SWPPP requirements My project is not located Inside or vvittiln 200 feet of an envirorunentaUy sensitive area with a significant potential for contributing pollutants to nearby recriving waters bf way of storm water runoff or nort-storm water disctwge(s). V My project does not require a grading plan pursuant to the Carlsbad Grading Ordinance (Chapier 15.16 ofthe Cartsbad Municipai Code) My project ^11 rwt resutt in 2,500 square feet or rnore of soils disturtance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets one or more ofttie additional following ciit«ta: • located within 200 feet of an environmentally sensitive area or the PacHic Ocean; and/or, • distul>ed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or • disturbed area is located alorig or wittiin 30 feet of a storm drain inlet, an open drainage ctiannel or watercouise; and/or • consfruction wHI be initiated during ttie rainy season or wiii extend into the rainy season (Oct. 1 through April 30). I CERTIFY TO THE BEST OF m KNOWLEDGE THAT AU. OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMrPriNG FOR crrr APPROVAL A TIER I CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WTTH THE REQUIREMENTS OF CrrV STANDARDS. I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVTHES TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND, C2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS cmr APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVmES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CrTY OF CARLSBAO. STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACIUTATE RAPID INSTALLATION OF EROSION AND SEDIMEhfT CONTROL BMPS WHEN RAIN IS EMINENT. 2. THE CWNER/COMTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKINQ ORDER TO THE SATISFACTION OF THE CfTY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL 3. THE OWNER/CONTRACTOR SHALL INSTALL ADDrriONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CTTY ENGINEERING OR BUILOING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABIUTY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL 5. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. SPEQAL NOTES PROJECT IWFORMATIOW SiteAddress: ItaOO ?>\iBH^ VUVTA VU/^y Assessor's Parcel Nisnber. ProlectID: «^ fS Q^l I Construction Permtt No. Cist^ IHIH- Estimated Construction Start Date Project Duration ^tt€> Months Emergency Contact: Name: 24 hour Phone: Perceived Threat to Storm Water Quality ^r'^Medium • Low If medium box is clieciced, must attach a site plan sheet stiowing proposed worl< area and location of proposed structural BMPs For City Use Only CFTY OF CARLSBAD STANDARD TIER 1 SWPPP Approved By:. E-29 Page 1 of 3 REV4A3Q/iO Erosion Control BMPs Sediment Control BMPs Trackbig Control BMPs Non-stonn Water Manaoemant BMPs Waste Managemant and Matarlals Pollution Control BMPs Best ManaganMnt Practice (BMP) Description I m I f a I CASQA Dosignation Constniction Activity 3 3 Ui (0 •9 IU to i Grading/SoB Dl«tt«t>ance TrancNnfl/EXcavailon StocMIng z: DrlHnfl/Borii«" ConcreleMsphalt Saw cutting Concreie flatworic Condult/Pipe Installation Stucco/Mortar Work W^ Dispoaal Staging/La! Equipinent ig/Lay Down Area Maintenance' 1^ widFUeftTg nHazardouB Substance' Use/Storage Dewatering 8»f Accew Across Dirt Other fliBt): manaoernart B*^SimiS*^*^?«!^ check In the box immediateiy tothe left ofthe added adhrtty descripUon. Fbr each activity descnibed pkA one or more best tha lst tor something that iSSeTSS?*^ Ingress/Egrasr cohrin andSoaaTx in^hr^^Sh^!!^^ "^"^ TracWt^Conlrol. Folkwv atong the "Site Access Across Dirt" row is4ll you get to the 'Stabifeed Constiuction E-29 Page 2 of 3 REV4/3(yiO ^ CITY OF CARLSBAD PLANNING DiVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 Development Services Planning Division 1635 FaradayAvenue (760) 602-4610 www.carlsbadca.eov DATE: 6/11/13 PROJECT NAME: King Property PROJECT ID: MS 13-02 PLAN CHECK NO: CB 13-1414 SET#: n/a ADDRESS: 1600 Buena Vista Way APN: 156-142-40-00 ^ This plan checl< review Is complete and has been APPROVED by the Planning Division. By: Chris Garcia A Final Inspection by the Planning Division Is required • Yes ^ No You may also have corrections from one or more of the divisions Usted below. Approval from these divisions may be required prior to the issuance ofa building permit Resubmitted plans should Include corrections from all divisions. This plan check review Is NOT COMPLETE. Items missing or Incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: Gary Cohn For questions or clarifications on the attached checklist please contact the following reviewer as markeci: PLANNING 760^02-4610 ENGINEERING 760-602-2750 IIRipREVE • ••760-^2^665/' 1 1 Chris Sexton 760-602-4624 Chrls.Sexton@carlsbadca.gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov Q Greg Ryan 760-602-4663 Gregory.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov Q Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gOv X Chris Garcia 760-602-4622 Chris.Garcia@carlsbadca.fiov • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gOv Remarks: Plan Checl< No. CB 13-1414 Address 1600 Buena Vista Wav Date 6/11/13 Review # 1 Planner Chris Garcia Phone (760) 602- 4622 Type of Project & Use: Existinq sinqle familv home remodel Net Project Densitv:n/a DU/AC Zoning: RJ. General Plan: RLIVI Facilities Management Zone: 1 CFD (in/out) #_Date of participation:n/a Remaining net dev acres:pendinq subdivision map (For non-residential development: Type of land use created by this permit: ) REVIEW #: 12 3 Legend: ^ Item Complete • Item Incomplete - Needs your action IEI • • Environmental Review Required: YES • NO IEI TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: IEI • • Discretionary Action Required: YES • NO I3 TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: ^ D n Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES Q NO M CA Coastal Commission Authority? YES • NO JEl If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego. CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): 13 • • Habitat Management Plan Data Entry Completed? YES • NO • If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) IE! • • Inclusionary Housing Fee required: YES • NO |E1 (Effective date of Inclusionary Housing Ordinance - May 21,1993.) Data Entry Completed? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) IEI • • Housing Tracking Form (form P-20) completed: YES • NO • N/A Kl p-28 Page 2 of 3 07/11 Site Plan: K • • Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. City Council Policy 44 - Neighborhood Architectural Design Guidelines • • 1. Applicability: YES • NO IEI • • 2. Project complies: YES • NOn Zoning: • • • • • • • • • • • • 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required Required Required Required Required 2. Accessory structure setbacks: Front: Interior Side: Street Side: Rear: Structure separation: 3. Lot Coverage: 4. Height: Required Required Required Required Required Shown Shown Shown Shown Shown Shown Shown. Shown Shown. Shown Required <40% Shown 20.1% Required <30; Shown <30' 5. Parking: Spaces Required 2 covered Shown 2-car qaraqe (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE 6/11/13 p-28 Page 3 of 3 07/11 CERTIFICATION OF Development Services ^^^^ " ^ CITY OF SCHOOL FEES PAID Building Departnnent 1635 Faraday Avenue CARLSBAD B-34 760-602-2719 www.carlsbadca.gov This form must be completed by tlie City, the applicant, and the appropriate school distiicts and returned to the City prior to issuing a building permit The City will not issue any building permit without a completed school fee form. Project Name Building Permit Plan Check Number: Project Address: A.P.N Project Applicant (Owner Name): Project Desaiption: Building Type Residential: Second Dvi«lling Unit: Residential Additions: Commercial/lndustrial: City Certification of Applicant Infomiation.- KING RESIDENCE Proiect ID: CT/MS: CB131414 1600 BUENA VISTA WY 156-142^0-00 KING COMMUNITY TRUST RESIDENTIAL ADDITION RESIPENHAL NEW DWELLING UNIT(S) 582 Square Feet of Living Area in New Dwelling/s Square Feet of Living Area in SDU Net Square Feet New Area Net Square Feet New Area Date 11/14/2013 SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD 1^ Carlsbad Unified School District 6225 El Camino Real Carlsbad CA 92009 (760-331-5000) Q Encinitas Union School District 101 South Rancho Santa Fe Rd Encinitas. CA 92024 (760-944-4300x1166) n Vista Unified School District 1234 Arcadia Drive Vista CA 92083 (760-726-2170) n San Marcos Unified School District 255 Pico Ave Ste. 100 San Marcos. CA 92069 (760-290-2649) Contact: Nancy Dolce (By Appt. Only) LJ San Dieguito Union High School District-By Appointment Only 684 Requeza Dr. Encinitas, CA 92024 (760-753-6491 x 5514) Certifk^tion of Applicant/Owners. The person executing this dedaration fOwner^ certifies under penatty of perjury that (1) the infonnation provided above is conect and true to the best of the Owner's knowiedge, and that the Owner will file an amended certification of payment and pay the addKional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is Issued or if the initiai determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described pr(4ect(s), or that the person executing this declaration is authorized to sign on behalf of the Owner. Signature: Date: 4 «t o SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(s)) * ** ***************************************4MHIr*^ THIS FORIVI INDICATES THAT THE SCHOOL DISTRICT REQUIREIIENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. SCHOOL DISTRICT: The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project. SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL TITLE ' JAJ^LS§AD UNIFIED SCHOO no SCHOOL DISTRICT NAIVIE OF SCHOOL DISTRICT 5225 EL CAMINO REAL CARLSBAD.CA 92009 DATE PHONE NUMBER B-34 Page 2 of 2 Rev. 03/09 ^ CITY OF CARLSBAD PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET B-18 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carisbadca.gov Project Address: Permit No.: [j^ f ^ ^ ^ ^ Information provided below refen to wort? beng done on the above mentioned pemiit only. This form must be completed and returned to the Buildinq Pivision before the permit can be issued. Building DepL Foc (760) 602-8558 No Number of n»u or relocated ffoctures, traps, or floor drains...................................... New building sewer line? . . ...... ......... ........ ... .... .. Ves_ Number of new roof drains?... Install/alter water line?.. Number of new water heaters?.. Number of new, relocated or replaced gas outlets?. Numi3er of new hose bibs?..... .. .................. ..................... If loo-^f: Residential Pennits: New/expanded service: Number of new amps: Minor Remodel on^* Ves No Commercial/industrial: Tenant Improvement Numiaer of existing amps invoh/edin this project: Number of new amps involved in diis proiect: New Construction: Amps per Panel: Single Phase Three Phase. Three F>hase480. , Number of new amperes, , Number of new amperes_ , Number of new amperes_ Number of new fumaces, A/C, or heat pumps? New or relocated duct worfo? Number of new fireplaces? Number of new exhaust fans?, Relocate/install vent?....... Numi3er of new exhaust hoods? Number of new boilers or compressors? B-18 Page 1 of 1 Rev. 03/09 CB131414 1600 BUENA VISTA WY KING TRUST-CONVERT 482 SF OFEX FXIRTINR OARAGE TO FAMILY ROOM, BUILD NEW 515 Approved / •cv Date BUIU3ING PLANNING ENGINEERtNG FHRE Expedite? Y N Ml 5SL AFS Checked by: HazMat APCO Health Forms/Fees Sent Rec'd Due? Encina Fire HazHealthAPCD PE&M School C'/f^ Sewer Stomnwater Special Inspection CFD: Y N LandUse: By Density: ImpArea: FY: Annex: Factor: PFF: Y N Comments Date Building Plannirjg Engineering Fire Date Date Date miL b3K Meed? )/W BDone I Done (Done '• Done • Done