Loading...
HomeMy WebLinkAbout1600 FARADAY AVE; ; CB011007; PermitCity of Carlsbad · 1635 Faraday Av Carlsbad, CA 92008 v' 02jt7 3b 05/29/2001 Commercial/Industrial Permit Permit No: CB011007 Building Inspection Request Line (760) 602-2725 Job Address: 1600 FARADAY AV CBAD Permit Type: Tl Sub Type: Parcel No: 2121304200 Lot#: Valuation: $112,500.00 Construction Type: Occupancy Group: Reference #: COMM 0 NEW Status: Applied: Entered By: ISSUED 03/14/2001 CB Project Title: 05/29/2001 INVITROGEN/INTERIOR REMOD-PH 1 Plan Approved: 7500 SF OF MANF. -MANF, WALLS, ELECT,COLUMN Issued: 05/29/2001 Applicant: MICHEAL KINOSHITA 14308 MARIANOPOLIS WY SD 92129 858-484-3613 Total Fees: $1,205.52 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Inspect Area: Owner: CR C PROJECT ONE LP 059~ OE;: ,.,9 '"1 '\/\(•") A•J C/O HAMANN CONSTRUCTION' .u ..:.. 1 v (.'II i..:. '-'-,...,G.-. 475 W BRADLEY AVE "-'· .-·· EL CAJON CA 92020 Total Payments To Date: $381.29 Balance Due: $824.23 $586.60 $0.00 $381.29 $0.00 $0.00 $23.63 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee: Sewer Fee: Redev Parking Fee: Additional Fees: TOTAL PERMIT FEES FINAL APPROVAL Date: / /2'!µ1.---1 Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $97.00 $60.00 $57.00 $0.00 $0.00 $0.00 $0.00 $1,205.52 NOTICE: ase take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. 02 °Jc__ PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 A FOR OFFICE USE ONLY PLAN CHECK No(eci/ {)()] EST. VAL.// :).,J?JO .• -- Plan Ck. Deposit :3~ l I! ':}q Validated ByC:::: Date ·3/ / :1../.£)_ / 3934 03/14/01 0002 Oi Total # of units Telephone# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged e_;5(lmptio91. ~ v;plation of Section 7031.5 by any applicant for_ a permit subjects the a,E>plicant to a civil penalty of not more than five hundred dollars [$500]). ~+~:ed-s: :;:tk.c:.. 2'320 Coev:::,~ er. , chsr-~ c.4-7W/'Sf:8'-74, C4 State License# C/ tp!/1 / :~. :·-woi{&~l'ts'.< ~b-MP.~A:'i(ON-. .. .. . . .,_, .... -~-,, •.. Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ~ave and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carri:r and policy number are: 1 /, / Insurance Company.5fa:fc: Cr:mtp~fia/fl'rcm ~UA Policy No. 333• 'Jt{~ -00 Expiration Date li!Jt/t<!Jf (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars 10 0 , in add' ion to the cost of compensation, damages as provided for in Section 3706 of th~bor code, interest and attorney's fees. SIGNATURE ' DATE s-aw ( -2 .... ~ :t!wNi; ,.1Ivi~P1;:n, oeJ:;i;ARA11or,, . .. . . . . • I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(sl licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 Y.ES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with t_he following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number/ type of work):. _______________________________________________________ _ PROPERTY OWNER SIGNATURE ______________________ _ DATE _________ _ : c~:iMP.(l;T!=)'HI~' $!3Ctiptf1i:9a. l)ioivtflESll:iEN:TIA{.' Bi,lltDIN<f PE,RMIT~.QNL y' .. "' . Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. f~~-~~-:.CONStRUP"flOrf(eNPt~G.AGeNCY n, .. -~ -~ --:~·=-· -_ I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME______________ LENDER'S ADDRESS ________________________ _ :~.. .-A(!PLJQ..l\N.T'(:,E{fflFtCft'.J'!Qtf .· . ' . . · ' ;: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued y the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not co need within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is com,.,,.n.,,m .. ur a period of 180 days (Section 106.4.4 Uniform Building Code). Inspection List Permit#: CB011007 Type: Tl COMM INVITROGEN/INTERIOR REMOD-PH 1 7500 SF OF MANF. -MANF, WALLS, ELEC Date Inspection Item Inspector Act Comments 01/24/2002 89 Final Combo TP AP 01/24/2002 89 Final Combo RI 8:30AM INSPECTION PLEASE 01/07/2002 89 Final Combo TP co 12/11/2001 89 Final Combo TP co 12/03/2001 89 Final Combo TP NS 11/21/2001 89 Final Combo TP CA 08/28/2001 89 Final Combo TP co SEE NOTICE ATTACHED 08/20/2001 89 Final Combo TP NR NOT COMP. 08/17/2001 89 Final Combo TP NR . 08/14/2001 89 Final Combo TP NR 06/26/2001 14 Frame/Steel/Bolting/Weldin TP t\P EXIST. T-CEIL SEISMIC UP-GRADE 06/26/2001 24 Rough/Topout TP WC 06/26/2001 34 Rough Electric TP AP EXIST. LITES 06/26/2001 44 Rough/Ducts/Dampers TP AP EXIST DUCTS 06/21/2001 14 Frame/Steel/Bolting/Weldin TP co T-CEIL 06/21/2001 14 Frame/Steel/Bolting/Weldin TP AP 06/21/2001 17 · Interior Lath/Drywall TP AP SEE CARD 6/21 06/21/2001 24 Rough/Topout TP WC 06/21/2001 34 Rough Electric TP WC 06/21/2001 44 Rough/Ducts/Dampers TP WC 06/11/2001 14 Frame/Steel/Bolting/Weldin TP AP T-BARCEIL 06/11/2001 24 Rough/Topout TP WC 06/11/2001 34 Rough Electric TP AP CEIL LITES 06/11/2001 44 Rough/Ducts/Dampers TP AP DUCTS 06/11/2001 84 Rough Combo TP co 06/01/2001 14 Frame/Steel/Bolting/Weldin TP AP FERM WALLS 06/01/2001 15 Roof/Reroof TP NR NOT PER PLAN 06/01/2001 17 Interior Lath/Drywall TP AP FERM WALLS 06/01/2001 23 Gas/Test/Repairs TP AP MED PSI 06/01/2001 24 Rough/Topout TP AP FERM WALLS 06/01/2001 34 Rough Electric TP AP FERM WALLS 05/31/2001 15 Roof/Reroof TP NS 05/31/2001 23 Gas/Test/Repairs TP NS 05/31/2001 24 Rough/Topout TP NS 05/30/2001 14 Frame/Steel/Bolting/Weldin TP NR NO CONTACT PERSON 05/30/2001 23 Gas/Test/Repairs TP NR 05/30/2001 24 Rough/To pout TP NR Friday, January 25, 2002 Page 1 of 1 CilY of Carlsbad · Final Building Inspection Dept: Building Engineering Planning CMWD St Lite tfr~ Plan Check #: Date: 08/17/2001 Permit#: CB011007 Permit Type: Tl Project Name: INVITROGEN/INTERIOR REMOD-PH 1 Sub Type: COMM 7500 SF OF MANF. -MANF, WALLS, ELECT,COLUMN Address: 1600 FARADAY AV Lot: 0 Contact Person: MIKE Phone: 7604970463 Sewer Dist: CA Water Dist: CA .......................................................................................................................................................... Inspected ~~ Date /)/, .,,,/ ~ By: ~ ,J Inspected: -----,o/._V l:~VO/~,___Approved: ___ Disapproved: __ Inspected Date By: __________ Inspected: ______ Approved: ___ Disapproved: __ Inspected Date By: Inspected: _____ Approved: ___ Disapproved: __ ............................................................................................................................................................ Comments: ______________________________ _ EsGil Corporation In Partnership with Government for Building Safety DATE: 5/24/01 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 01-1007 PROJECT ADDRESS: 1600 Faraday Ave SET:111 PROJECT NAME: lnvitrogen Remodel Phase I -TI f:?~NT ~ D PLAN REVIEWER D FILE 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. D The plans transr:nitted herewith have ·significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicc!lnt's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: iV Date contacted: (by: ) Fa : Mail Telephone Fax In Person / [?3J REMARKS: Applicant to provide note on title page m d in red and provide revised hazardous material report page 7of 47 indicating no use of Gia 1,11 or Ill liquids in the area of the tenant improvement ( to be reviewed and approved by rlsbad Fire Department). By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: LOG trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with Government for Building Safety DATE: 5/ 16/01 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 01-1007 SET: II PROJECT ADDRESS: 1600 ·Faraday Ave PROJECT NAME: Invitrogen Remodel Phase I -TI D~L[fANT ~ D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted he~ewith have significant deficiencies identified on the e"nclosed check list and should be corrected and resubmitted for a complete recheck. rg:j The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [Z] The applicant's copy of the check list has been sent to: Michael Kinoshita 14388 Marianopolis Way, San Diego, Ca. 92129 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Michael Kinoshita -Telephone#: 858-484-3613 Date contacted:..S) I\# lo t (by: FA)<.) Fax #: 858-484-6239 Mail l..A'elephone D REMARKS: Faxv In Person By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 5/8/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 01-1007 II 5/16/01 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 1600 Fa;raday Ave DATE PLAN RECEIVED BY ESG_IL CORPORATION: 5/8/01 REVIEWED BY: Doug Moody FOREWORD (PLEASE·READ): PLAN CHECK NO.: 01-1007 SET: II DATE RECHECK COMPLETED: 5/16/01 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit three new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? OYes DNo City of Carlsbad 01-1007 II 5/16/01 These corrections are ·in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 1. A complete description of the activities and processes that will occur in this tenant space should be provided. Is there an existing hazardous materials report which may be required to be up-dated? Does the tenant improvement change the quantities of hazardous materials. The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 307.1.6. The hazardous material report states that there will be Class 1,11, and Ill liquids used in the area of the tenant improvement and further that all use and transfer shall be done within listed fume hoods. Please show the location of all fume hoods on the mechanical, Electrical and architectural plans. Please provide complete listing information for the fume hoods. 2. Please provide the manufacturers listing information for the new equipment. No Response 4. Please indicate on the plans the types of exhaust from the cold box, the plans show a hood. Are class 1,11 or Ill liquids to be vented? Please clarify the exhaust fan #19 drawing from the cold box and a grill .(listed in your response sheet as exhausting carbon dioxide) is not shown on the roof plan, does this fan exhaust to the exterior? 6. Please indicate on the plans where the make-up air for exhaust fans #20 (outside the cold box) and exhaust fan #19 are provided. Please indicate if the exhaust fan #19 is for a fume hood above equipment #203T? Please show the exhaust and make-up air to be interlocked. l EsGil Corporation In Partnership with Government for Building Safety DATE: 3/22/01 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 01-1007 PROJECT ADDRESS: 1600 Faraday Ave PROJECT NAME: Invitrogen -TI SET:I D~ ~ D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. rg:j The applicant's copy of the check list has been sent to: Michael Kinoshita 14388 Marianopolis Way, San Diego, Ca. 92129 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Michael Kinoshita,......-Telephone#: 858-484-3613 Date contacted: ~:),;;,-(byI5 ) Fax #: 858-484-6239 ..--:: Mail Telephone Fax / In Person D REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 3/15/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 01-1007 3/22/01 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 01-1007 OCCUPANCY: B/Fl/S1 TYPE OF CONSTRUCTION: IIIN ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 3/14/01 DATE INITIAL PLAN REVIEW COMPLETED: 3/22/01 FOREWORD (PLEA~E READ): JURISDICTION: City of Carlsbad USE: Office/Manufacturing ACTUAL AREA: 7500 STORIES: 2 HEIGHT: OCCUPANT LOAD: 36 DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/15/01 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. · To speed up the recheck process. please note on this list (or a copy) where each correction item has been addressed, i.e .• plan sheet number, specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot City of Carlsbad 01-1007 3/22/01 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. A complete description of the activities and processes that will occur in this tenant space should be provided. Is there an existing hazardous materials report which may be required to be up-dated? Does the tenant improvement change the quantities of hazardous materials. The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection from hazardous. materials. Section 307 .1.6. 2. Please provide the manufacturers listing information for the new equipment. 3. Please indicate the method of cooling the cold box, will it be connected to the existing refrigeration system or is a separate system to be provided. Please provide complete plans. 4. Please indicate on the plans the types of exhaust from the cold box, the plans show a hood. Are class 1,11 or Ill liquids to be vented? 5. Please indicate if the relief vent has dampers and show exhaust fan #20 and the relief vent interlocked. 6. Please indicate on the plans where the make-up air for exhaust fans #20 (outside the cold box) and exhaust fan #19 are provided. 7. Please clarify the scope of work under this permit, the electrical sheets show two new Heat Pumps #43, #44 but they are not shown on the Mechanical sheets, the Plumbing plans show new compressed air and DI water lines. 8. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. ~1 / City of Carlsbad 01-1007 3/22/01 • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM FIELD WELDING REQUIRED? REMARKS 9. When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. 10. Please provide calculations to show the combustion air adequate for the new boilers. 11. Complete the plumbing plans, including: a) Provide gas line plans and calculations, showing pipe lengths and gas demands. UPC Section 1217.0 b) Show water heater size, type and location on plans. UPC, Section 501.0 12. Please complete the load summary. 13. Please complete the panel schedules. 14. Please note or show on the plans that all electrical penetration to the cool box shall be sealed per section 300-7 of the NEC. 15. Provide engineering calculations for design of cool box, the support for the cool box roofing panels. Have the engineer stamp seal and sign the calculations. Have the engineer include in the calculations all vertical and lateral loading, insulated panel spans, attachment to the floor and the existing walls. UBC Chapter 16 requirements. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D J 4. City of <;:arlsbad 01-1007 3/22/01 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgll Corporation. Thank you. City of Carlsbad 01-1007 3/22/01 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody BUILDING ADDRESS: 1600 Faraday Ave BUILDING OCCUPANCY: B/F /S BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Tl 7500 CitvValuation Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1994 UBC Building Permit Fee . I • I 1994 UBC Plan Check Fee Type of Review: 0 Complete Review D Other PLAN CHECK NO.: 01-1007 DATE: 3/22/01 TYPE OF CONSTRUCTION: IIIN Reg. VALUE ($) Mod. I D Structural Only D Repetitive Fee =:ERepeats D Hourly .__ ___ ....,I Hour(s) * Esgil Plan Review Fee Comments: 112,500 112,500 $666.581 $433.271 $346.621 Sheet 1 of 1 macvalue.doc PLANNINC/ENCINEERING APPROVALS RESIDENTIAL RESIDENTIAL ADDITION MIN.OR ( < $10,000.00) ... ~~ TENANT IMPROVEMENT PLAZA CAMINO REAL \, ' ., CARLSBAD COMPANY ST:C,RES VILLAO' FAIRE COMPLETE OFFICE BUILDING OTHER __________________ _ DATE ------- Dac:s/Mlsforms/Planning Engineering AOprovals --<::> 9 ii, '1) -. M \J) 2 .!!l .!!l "' "' nl 0 Cl Cl <.!> ~ 0- >, >, >, J:l .0 .0 ;;;; N ~ 'It, -"' .,,_ u .., " 0) Q) Q) .s::: .s:: .s:: (.) (.) (.) C: C: C: "' nl nl a: a: a: '¢0 D ~DD )100 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB O I jOO 7 Planner Paul Godwin APN: ?, \?,-L30-~5-00 Address I (OD l'.=araclt:ty Phone 760-602-4625 0:ve.. Type of Project & Use: :tcdustn'g [ Net Project Density: _____ D __ Ua.;../~A,.a;.C_ Zoning: C (Y) General Plan: P :I.. Facilities Management Zone: ___ _ CFD (in/out) # __ Date of participation: ____ Remaining net dev acres: __ _ Circle One (For non-residential development: Type of land used created by this permit: __________________ ) Legend: [ZI Item Complete D Environmental Review Required: YES Item Incomplete -Needs your action NoXTYPE __ _ DATE OF COMPLETION: _____ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: ______________________ _ Discretionary Action Required: YES __ NO£ TYPE ________ _ APPROVAURESO.NO. ___ DATE __ _ PROJECT NO. ___________ _ OTHER RELATED CASES: _________________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: _____________________ _ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES __ No£ CA Coastal Commission Authority? YES__ NO __ If California Coastal Commission Authority: Contact them at -7575 Metropolitan Dr, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES__ NO __ If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. H:\ADMIN\COUNTER\BldgPlnchkRevChklst i : \ii ,D, ._ -__ , · D , -·lnc:lu$ionary Housing. Fee required: YES ___ NO ¼_ ~-· (~ffective 9ate·of lncl!,Jsipn?ry·H9using Orgihance ~ May·21, 1993.), · · · .·:•_--_:o·-o -~---'' ----o--:o· o--. '. -_ ' : ·_ '.' :_ . ' ' ., . Dat? l;n~r_y C~mpl_eted? Y~S_, __ · -: NO~ .• 1 . _ . , : _ . ·_ _- -,(NP/Ds,.Act1v.1,ty MaInteni;).nce, enter CB4t,·toolbar; Scr~ens,H9,us1ng•Fees, Cqn,struct Housing Y/N, Enter f_ee, UPDATE!) Site Jllan: '. · 1., Provide· a fuliy dimensiorial· site· plan orawn to scale. -Show:. -North arrow,. property lines, : 98.§enients, , existing· and proposed . structures, streets, exi$tirig street irnptovement$, right;.of-wqy Width,. dimensional $etbacks and existing top>ogr:aphical .-line_s; · · · ·. · 2. Provkie legar·gl35cripti:o'n :of f2)roperiy atid assessor's parcel number.. · Zoning:. . 1 ., .Setpacks-: . Front: . . Interior S'ioe: Street Side: Rear: Re~fui red.-----'--,-'----,--.----,---Shown --'--,----,-,---- .Required __________ Shown------"---'-'---'---''-- ,Req ~ired ;_;.: .__ '----,--'------,---Shown .:....· --'--,---,.,---'-----,------,- Heq u i req_ Shown----'---,----,---,--- D D 0: .2. A9cessory-structure setbacks: \ I L 'I' • I I ' I, ,· I·_ ·D·O'D ,·.~DD a10 ' I, I . I. Front Interior Slde: Stteet Side:· Rear:· . Structure separ~~io11: 3. Lot Cover?ge, 4. -Height 'R~quired .. ----"'-'-'----'--"---,--~"'""'" Shown--...;;,.;---,,-;,---,.,-- , ·i=teqLfired _,: Shown---___,.-,---- Hequ'ired. Shown --,----,----'--- . Required . Shown ----,----:---,--- :Required .. · Shown __ __,,.-,---,,...--- -Reqoi red:~-----,-,---,---,-----,--Shown ----,---,---+ ', ' Requ'ired -,-----'-'-'-----Shown ----,-----_,_ 5. Par!<inf;F Spaces _Requ1red__,._-_ ______,.:l,_c./ ____ .-__ ____, Shown _ _,_J x..,{£."-,-. _--,---- Gu-est.Spaces ·Required· Shown: _ _____..--'--_,__ __ _ Additiona1·oorm;rtent$ _ (y p leo , C ~-ho \ct?· __ . e le ,; et {;: Qn 5 : ,of :@,·>op a· s ~ d too+' · oK rn 1ssvEAND APPRovA~ ENTERED 1NT0 coMPLJtEROavOJMm, ' , , oATESit,foJ . .bl:\AD.MIN\COUNTER\B!dgPlnchkRevChklst - .9,arltbad Fire Department 011007 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: ,Building Plan Reviewed by: Date of Report: _os_1_10_12_0_0_1 _______ _ Name: MJK Architecture Address: 14388 Marianopolis Way City, State: San Diego CA 92129 Plan Checker: Job #: 011007 ------- Job Name: lnvitrogen Bldg #: CB011007 -------------------"-- Job Address: 1600 Faraday Avenue Ste. or Bldg. No. IZI Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this rep·ort can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. \ The item you have submitted for review is incomplete. At this·time, this office _cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 011007 2nd FD File# 3rd Other Agency ID ., Carl~bad Fire Department w_ 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Date of Report: . _o_5/_10_12_0_0_1 _______ _ Name: MJK Architecture Address: 14388 Marianopolis Way City, State: San Diego CA 92129 Plan Checker: Job Name: lnvitrogen Job Address: 1600 Faraday Avenue Reviewed by: 011007 011007 Fire Prevention (760) 602-4660 Ste. or Bldg. No. Plans to be design per technical report. Directional exit signs may be required. Carfsbad Fire Department 011007 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Fire Prevention (760) 602-4660 Date of Report: _0_31_20_1_20_0_1 _______ _ Building Plan Reviewed by: Name: MJK Architecture Address: 14388 Marianopolis Way City, State: San Diego CA 92129 Plan Checker: Job #: 011007 ------- Job Name: lnvitrogen .Bldg #: CB011007', ------------------ Job Address: 1600 Faraday Avenue Ste. or Bldg. No. D Approved D Approved Subject to ~ Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 011007 2nd FD File# 3rd Other Agency ID Req'u-irements Category: Building Plan "~-----------------------------------------~ Requirement: Pending 05.14 Provide Technical Report To determine the acceptability of technologies, processes, products, facilities, materials and uses attending the design, operation or use of a building or premises subject to the inspection of the department, the Chief is authorized to require the owner or the person in possession or control of the building or premises to provide, without charge to the jurisdiction, a technical opinion and report. The opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety properties of the design, operation or use of the building or premises and the facilities and appurtances situated thereon, to recommend necessary changes. Provide tech report for all new areas. You may want to design the tech report for phase I and phase II. Requirement: Pending 05.25 Exit Signs Section 1013.1 Where Required. When two or more exits from a story are required by Section 1013.4, exit signs shall be installed at stair enclosure doors, horizontal exits and other required exits from the story. When two or more exits are required from a room or area, exit signs shall be installed at the required exits from the room or area and where otherwise necessary to clearly indicate the direction of egress. EXCEPTIONS: 1. Main exterior exit doors which obviously and clearly are identifiable as exits need not be signed when approved by the building official. 2. Group R, Division 3, and individual units of Group R, Division 1 Occupancies. 3. Exits from rooms or areas with an occupant load of less than 50 when located within a Group I, Division 1.1, 1.2 or 2 occupancy or a Group E, Division 3 Day-Care occupancy. Illumination: Signs shall be internally or externally illuminated by two electric lamps or shall be of an approved self-luminous type. Power Supply: Current supply to one of the lamps for exit signs shall be provided by the premises' wiring system. Power to the other lamp shall be from storage batteries or an on-site generator set. Show existing exit signs and add new signs if needed. Requirement: Pending 05.32 Additional Requirements or Comments Provide comment on plans stating seperate plans for all fixed & mobile fire protection equipment & all fire alarms shall be submitted to the fire marshal for approval prior to installation. Requirement: Pending 05.33 Plan Revision$' Page 1 Please submit 3 sets of corrected plans directly to the Building Department for routing to the appropriate departments. 03/20/01 ' . JOSEPH F. MONTAGNA Consulting Engineer 1315 Cordova Ave. • Glendale, California 91207 • (818) 244-0681 ~ . eKJ.f.o\~ee~\ ~<'6 P.. ~ A. ~ses U0 f.1.LK-' t-.J C'..i.::,O(-.~_ ~ -\;-{. ~~<o:a~-c-t r<:..eF~\<:ae ~~ T\C:N $~~· bdS. G C J. 0 P\ ..... fo,e.. ~-~~\O~f\.Lr GOO~~t~, ~~~\~. '2.CaJ o.oe> \ . 1:>'ITA I . ····-~-----.. +--' . . . ~\~~\C '1..C\Q5 4 C.; 4-\N·\.P.t\k,~ 0.-S-1~1ce.\tJ~ t..o~h~ ?t~JS$$..OR.:~ CpPSF -F~~fSL -cr~\C..X~, . '$~~ V:-~~ .. };(Q~ P\$\f\l\ ~-b.$3 G.s;. ~ .. ~'ZO ~\ ~R, ~.A.l),D . (~a,~,..,"t--·.0\9 (ty J ~~ l-\.,Ue ~\ ~~ ~\\~ b-~, te.z-,ro. L')tv\t W\t).T~ ·Ve;~~ 4 ~5. Lt~~ Cf\.M ~~ tz., 1"~ -e' (.Q.~r.+ ~-ei.~ \J)~L~ ~-~~t.. ~t> \{,v·--A \qu '"P?V b.~?-t\ ~~(J ~ \C~( ~-u~~-P~Na~ . . L~-~ \ ~~-... GL~~r~ oo-..;. '2' t;:,.L + \·O LL-,.,, , '3· -psp C--~ .. C":;,-\t--~ f\A,-; ..l.~\.?:., ~ ~l~ ~ t r1 'Ft-LB·.S e .. ~ ~--.l'i:). ·· ~-~Jl. f \ "'2... ~ Co~S1o P6'i 0 \<.. b bG* \~,S~~,,D\~ Z, t V~, )~ ~ ~ l~Gv, Ll5.:, 1-:f::., .. t?~ · --:.. 'Z-d ~I < W,, L\ CK : g:~~s 1 \Z. · h f,g1~ t.v 1_;'1(. D&b'i '· D) D.-.. l+ .. .. -D L12 , Gs, C G '2 t; . . 5.,,-5_? I .D~ Es--L ~ ":.. 'Z'i X /0 I .. 619 J / "2.. -:: g .. ~? X 101_ JOSEPH F. MONTAGNA Consulting Engineer 1315 Cordova Ave. • Glendale, California 91207 • (818) 244-0681 A_-.. Y( , s~~et '2 Of: 4 ~~9,7c:;,,\':3_t62( \,t ,Q~f,l.•~,'"2:to"\D ) ~,'::>~ ~ f b(;;, . , '2..l~ 1, 1,~Q I '::> A'$~ _ . ~ \. ; . "2...li\2:~ , •. •': o\<... ~ .9~. t~--4-,~·o ~ ~-~"'\'° Ci.f5\L.t~~ ?~~~t-6,~ ·-: .. _ : t ' ' ' .. ,. :· ••• ~-Oh--·-~--~---, ... -·~·-· --,--. .. -... h....:.:.:~~ ''f5==·--"J· '"Zf, \.\D~LL . ?~~at,.. . . . . ' . -b ',_,_ l 2.01"' l~ -:. t 3 f-WsS ...... L\ 11 ¼ ~ \ .. .. ...... r" · . ... ~ . C. · 1;;>.., 'aq x co'-, ,o l°l . 4 )/"l., ~-4 .40~ 'P.. lti~· I ~>.. l t._, r · · 1-vv--~· ~ ~ \·O -~ "-0<;;& ,=;,;,,.,.lJ3,.S · ~"' 1~:4'\; ,\l· -s. e?:Z ~sr OK. • V~6 L2 ..._ ~~ ~B-5 (,) 2 .. 1J' "..--..... ? :, ~ (:), i~ f:75 \ 0 l<"'- U... du Gc\l\fi,to t "'~D. LO·P...,,O i "'~ <i::tz:'"L ·\ 3 ~ · ..... -. -t· -. ~ b7,;l ~ \ t O 0\(.. ~ '2.t:ltl) (.Q 2-4 L~~~~~L Atv~LYS.e:-5 t:o--13 PS~ tO~~-'2(;;,,'DS ?Pl' • '2'6-:. 76S U3S JOSEPH F. MONTAGNA Consulting Engineer 1315 Corq.ova Ave. • Glendale, California 91207 • (818) 244-0681 u~~M,\ C. I ' . s~~~\ 3 OF 4 . v~ <.' '::) ~14L.\: I (, ~ J w .... 13C-w 4,$ . C~ILtNG t::> .. l-,-'2.,l,.~1r" 'c,,'5, ~~(.::"-·\~~ L's.S . ' . . .. ,o ._,, LP~-~~~~L.-1, ~L~bG7t7-.t)J ~ l 3P$'7 ~ t.4CVQ · "?J~-\0 Lf3.S V:-"~~-1 3 ?> (0 e--;.. l ~9 -~R>.S c:.s (L-t~~ ~,~~~.2A~N\ . ~ i~~o~ ,.rz,~ .. LS..5 \ ~ ~ a ~l,~1 ~ l7l ii,-. \ -Z ( ~ \ ~ sa.. ps f 4 ~ '"'2.,~ at:__ . ·7.. _6-f q ~be:,;:i~x ~l ''C-0\0\7 'Tbf=' TRJN\ w/ ~ 't,. \ ~~b (£ ~ 0 I/ 0. r ~( C)~ ~u.~"\<.. .. V -4' ·\,-':f.=>9 ~ c; ~o L-i1·~-s ~ ~-.... ~ -·~ "LJ~ Ooof? ~ 'L.Ut ~ ~ (q ~ OK . 'L.>\t ~ 7 . P~~eL tD ?A~-~L ~6tv1()~tf6N ' % --:. L\. ~s-::-\ ~, \ F.'1',, 'Z..i4 c~t,J\Loc:...K.s @ 4 1 o"c..,, N\A,.~ C\<- c.s,LttvG TO '--0~\-L c.Dtvtv"t;G'"t'\ON '>( ~ \~~ ~ c'.al=t Fl, .3/~-,~ )( ~,, LA<; @ 'Z'"&"I' 6iC: ".6K... JOSEPH F. MONTAGNA Consulting Engineer 1315 Cordova Ave. • Glendale, California 91207 • (818) 244-0681 s \.\-e:erc 4 6F 4- S.4l~~~ U:.,~L.L 1J"~ 52,0 =-~~ ~~ (~i~b7-~) . . . . ' l?;>A.. ~ ~·t-.:) \'.)·~(..:»"'"( \0 tJ > • >R •iR·,----.......... ,MM···-·-··'"·········---·-····-· ..... ~--· -·--~~~~ ·-r,o. \)D~~L ~~1'.J·$t-. ~ -+v ;.-:., \10 -. rt:..;:.._ .· ,.._" · · ~-.. ··-a-cf -!"C'.;_;]' • .......,_: T--'1 .#- ---:-:--: . A,.~(bL\; ~ D -~LOOe,_ ~ ~.. 3~ .. o -.. \ \., 2 ~'--~4 . \.4o\L\\ \IJ\O ~~c,~o{GS (J;· ""Lc/r O,G. 6{<_ (l ~ "B.O' ~'o'-0~ ) ' -M ~--.. ~, . ' ---: ,,."I STRUCTURAL CALCULATIONS for MECHANICAL UNIT SUPPORTS at JNVITROGEN ROOF 1600 Faraday Avenue Carlsbad, CA Prepared for: MJK Architecture & Planning 14388 Marianopolis Way San Diego, CA 92129 Prepared by: Devine Engineering 12316 Oak !<.noll Road, Suite C Poway, California 92064 858-7 48-6168 March 12, 2001 D.E. Job No.: 108.01 ·-_.,_, ... ------·-·· ... ---_________ .. DEVINE ENGINEERING 12316 Oak Knoll Rd., Suite C Poway, CA 92064 (858) 748•6168 .. '· JO!! _11::i~J::tB~~--f:;:oc.::,f w ~ST ___ .l9_S. <:;)~- sHtnNO.. . "l ____ o,_ ··- CHECKEOBY---____ OATF.. SCAL•---·· ·.~ .~ ~,., S. ~ · I · r • DEVINE ENGINEERING l l 884 Springside Rd. San Diego, CA 92128 (858) 748-61$8 i \..oAPl~W~ , ... , . ---1 ?-.OC;;i f!,. . . . CAP. 'SBe.i,; t ,.e~oPl=: -1/n'' o· : · '°SH-r-'r.:. · . :_,c. .. : rl;."IWQQO. . 1 '-1, : rj_ ;.~ ,0 ri'.41~ : : . : ... • _--·,-,( '-Q ,..:;. • 4, . • .f,O, (J • I • : • : 1 • : I tNS"iJl,,,.A,-iotJ .. .,. .... W~n~.K~~~ -s-.... , . ; ' ' . ,· .. ~~-..Jpl'n'S:c?:. f):"·o/· l--tUN~; .C.~H.:.1i--.t(q. i . ' . ':'~ ~~ : e ~'ii:C... ~ \ ~~-.... '.'2..'2 : ... \.? \. \ :. O,».b, t,$.· .. 1 .. 0 ... t'.-f:>, ; .. \:., .l : JtJa_l'b.l.Y1T~.J...1'0<>f: Yt-JJ.J: (2 \C2:,.o ~ _ StlEETNQ,_____ \ CF __ _ CAtCUlATcoe·v M:wP OATF-0$ ~ V2 ·.Q.L... CHECKl;O!W _____ _ DAIi'" ----------- SCALE ·; ~ .·. ' ... . . ! ' •: ·: , .. ; .1·z..o .. :. , . .. ...... ;Qo.b. ~~--(R~ou:~\..Ei) • • l • i .... }·. l • • ~-.. ! .. •: . ,:-. ; ....... :., . ..j., l .. ' ••I ' • ~' "•'~• -•"1,'" i ,}, .. ... ~-; ..... . .. L. • -~ r • • i ., ,. .•. ·: ···-:·· I •• ' •••• +···· ,{,-. . ~ ... f .... •'·· .... '· ,. ' !• I . ~-. . . . ' .; .. ! .•., ... ? .. f'1!))0Cf~lt--lll~t;io,r,1:ii;1 I">-•~: ---·-----··-------- • • • 2 00 I 1c 2: 0 8PM,1 iu:-GOOD & ROBERTS 7 6 0-5 9 8-765 9...ou11 No.7892 P. 1/3 Attention: Mr. d.ll&e Hedrick Date: 12/19/2001 Company: Good & Roberts, Inc. Number of Pages: Fax Number: 1-760~598-7659 Voice Number: From: Mike Devin& Company: Devine Engineering Fax Number: 858-748-6011 Voice Number: 858-7 48-6168 Subject Invitrogen -1600 Faraday~ Comments: Attached please find our detail (SX-101) and calculations for the new location of the roof mounted unit 3 p.Vl • • • \lvtDBC-20. 2001,c 2:08PM1, ,v:iGOOO & ROBERTS 760-598-7659,-ovll No.7892 P. 2/3 p.v.: DEVINE ENGlNEERIN.G, INC • 12316 Oak Knoll ~d., SUi~ C Pow~, CA 92064 (8581 748-(i168 JOB ;LJ111 "t'Ai>(atf,N SHEET NO. S:z':-\ 0 \ _ OF.-------- (1Al-()Ut.ATEOB.Y~..;:,.k:.e_'---~-Oi\iE /'J./!'fh( CtlF.Q(EOtl'l'r_---:..,i,t_b~-----D~iE_J.i/tr/t,J '·· . ...: ~) '6,-"' 40,«_ :r-,4,u;._ ;-. . ' . ' lt. . . . .. ,~) .. v-;. ;_pt.I"~~) : ... ~,,~~:p,OG f LI/'.--.,....--- ; Ro0Fi1t16' 011iA. 1 .. . : , .. -; · . .... .... ~) __ .. J.x.~ ,~~:,,; ; ~ 'lll-~ () c) .J.'. ~. ~:-Li.._...;.:-:..-.... -:_-_ ... _--.:..~_-..;;.J.A,...J ... po-_;~~-~ ..;,..._s~_, -_ ~ ..... -':."'"~~lf:-~~~~-~-:f\ .. : . . .• ·; :-· -·' . - 4'e"'-. ~6--, ... , .hrtA¥~ C, 1b ( ; . '. J~ (~1'5;,-~ ·~ . ; . ; -, --..\o--f---- _,J.f11-A)j6.,_~llS~ .. : '. .... . . . (¢i i ~~ -~~ ~:~ .. '. ~-.. ~::::::t:::t::d~Z~~:.:t:~:z:t :.. -· ~ .... , ···:··· ! .. .. : . ' ----~~;--·Ai4. ~~:,r"/ h ls~: : .. (~ ti/111'(' . ~t; /~:l!f .. -~~ ... ~-:JO,() /Jin . .,! .. ; __ A ! . ~EP. ~ ! ! i A!s ~ :• : ., .•. -.. ,~~-.. ., . .. : "),.."f'l ; . ; ! . . : . i --~ ' . .. ' ; t .; •• ' .. t·· "! ..... . __ , .. ~~~?~~~). i -.• .. ~; ....•.. :~~\~L: ~Qi::)~ ~t.At-f : .... . W i. i i· ---i -{ .... ;.\~ ~~4Pb~ A¥(:: --~~~-~ >$~, .. -, \Q \( ! .••. ! ·i··· ,__..i.,_.....___,..;_.,........, ff : . . ·_'._ ••. it,-..--i-.... ' ri... . . i ' ' . ' ' t-7"-"' ~'°} .>~A~;... ..1 ••• ~ .• .... ,._: I.. ...~ ~ • ,;. • i ' ! ! i·-· : -: ... . . ~ : '· .. _ .. , .. : . ;. .. i ___ _ . . ; ,( ..... I • ' . °I .... : ' •• J . ; : . . ~ ...... •. ! : ~ ..... ~ . ! ....... i . ; . • • • v111Dec.20. 2001,~ 2:08PM,. ,v:,GOOD & ROBERTS 760-598-7659,-ov11 No.7892 P · 3/3 p.v,> F---·--· DEVINE ENGINEERING, INC. 12316 Oak Knoll Rd •• $uib: C Pow&V, CA 92064 (858) 748-6168 1.oa•.o{_ l \ 5'-1£ETW0, ____ ,;;._ ____ OF ______ _ CJ\lCtJtA.TElH!Y:--J'""c_......._____ tJAlf._1.,;f:Z.:::;.}1.,;l:.,.;'t,,:-Vf'~f'--_ <;1<ECl(\:(J9Y __ _,l'l\:.....=.b::..i-----DA"tl:i_4j..:,3,'l-/ .... (~1,1:½.,._('/~''-""- ' : ®. :2-.-.··· 0 ............ -<:--: -1.·-;.. s•· o·~ 2-i(~p(i+:.o:~) ~ .~ (iifi'_:· . .., ·: : ·. ,n~~~-~ : 1.: -964:l';?~ : -.16i _;,~_)[.~ : : '.. . .,. (f.~~:,~ .. ; ._ """· . . . . . .. i~ /1cto/4. ~i i 1i¢~~ . ·_ \ ' • ·i· :•· -!·· "! .. :•• !·· ... ; ....... . ....: ..,_ \ O~f ~ii;J / .'. /7? ~ :-~~j,r. . -. · .. , ' .. ,V~.-:; .. : .• ! I . ' :-.. ~·;· -~·:··; . I I• •• i J~;·~. . . . ' ~ ~ .:. • .t.~ ' ...... !, •• ; ! ; .. .t --! . · ... ;· .. ! . ·' ~-··· .. . ..,. : I .. •. ~ .. --:, ... ·:--... ; ·; ., .. ~ .. ~-.l ·: .. - -.;. !-. ; ...... . l --; -· .. ' .... , ~ -.. : ... :. i' '®·,., . •:'"· : .l.. :. : . . -! -~-. : .. ;: L . : ! • •r: ........ ! ~-... { ..... ! . : ... : .. ' . . ..• .. . ... : ~.. . :" ' '" ' I•• .• .. I -~ .... l -; . .... +- i-··-· ···' ! ., .... 1 •• i.. . ,r, ... ! t ©-- ©-------'I 101.Q11 ~ CF-2 .J, .J, .J, .J, J, (N) COLD BOX # 1 139 COOLING FAN MOUNTED BELOW CEILING. TYP. FOR 4 ttt CF-2 CF-1 28'- 50'-011 = co _., N 7 /8" ID INSULATED COPPER RETURN LINE 1/2" ID INSULATED COPPER SUPPLY LINE 1 1/8" ID INSULATED COPPER RETURN LINE 1/2" ID INSULATED COPPER SUPPLY LINE COMPRESSORS LOCATED ON ROOF, TYP. FOR 2 NOTES: MARK MANUFACTURER PIPE SIZE IN OUT VOLTS PH HZ 'HP I REMARKS 1. REFRIGERATION-SEPARATE SYSTEM. CP-1 CP-2 2. REFRIGERANT -R-22 CF-1 CF-2 ,©--7 q_' .. ---= 'REFRIGERATION PLAN 1/8" = 1'-011 HEATCRAFT MOH030D73 7/8" 1/2" [208-230 3 50/60 1/3 HEATCRAFT MOZ060M63 l l/8" 1;2• 1208-230 3 50/60 1/3 I LCA 6-135 I I j208-230 1/15 I 3 FANS I LCA 6-260 I I j208-230 1/15 I 5FANS INVITROGEN -PHASE 1 TENANT IMPROVEMENT 1600 FARADAY AVENUE CARLSBAD, CA 92008 PLAN FILE NO.: CB 01-1007 ~ RF-1 ©-- N 1©-- ~ 101-0" ! 501-011 ~ ©--I I ~ I' --· ·-lJgg!J ~9 I CF-1 I I CF-2 .J, .J, .J, .J, .J, .J, .J, .J, (N) COLD BOX # 1 I 139 I co -' COOLING FAN ,- N 7 /8" ID INSULATED·COPPER = MOUNTED BELOW «v RETURN LINE CEILING. TYP. FOR 4 V 1/2" ID INSULATED COPPER I SUPPLYUNE - ttttt,1 ttt I I I CF-2 I 1 CF-1 I I 1/ 11/8'1DINSULATEDCOPPER I I I ~ RETURN l!N1' I I I / \., 1 , .C-1/2" ID INSULATED COPPER I ,_ SUPPLY LINE I I ·~ ., ~11 I C)C) ~ COMPRESSORS r~ 281-C .; J;~ ~~ LOCATEDONROOF, . CP-2 TYP. FOR 2 t_::.._:J OTES: MARK MANUFACTURER PIPE SIZE IN OUT VOLTS PH HZ HP REMARKS REFRIGERATION-SEPARATE SYSTEM. CP-1 ~ CP-2 REFRIGERANT -R-22 CF-1 CF-2 -PG 71<EFRI~ ~ATION PLAN l/811 = 11-0" HEATCRAFT MOH030D73 7/8" 1/2" ~08-230 3 50/60 1/3 HEATCRAFT MOZ060M63 1 1/8" 1/2" ~08-230 3 50/60 1/3 LCA 6-135 208-230 1/15 3 FANS LCA 6-260 208-230 1/15 5FANS ~ INVITROGEN -PHASE 1 TENANT IMPROVEMENT 1600 FARADAY AVENUE CARLSBAD, CA 92008 PLAN FILE NO.: CB 01-1007 RF-1 . I ~ , . . , I I Mar 2S 01 12:34p Sent By: NATIONAL COOt..F:f,; HAGGERTY REFRIGERATION 619 670 Mar-28-0t 3:~4~Mi 6690 9095924839; ''-'':1 ... CtTY OF Los ANGELES /"_.·:5 \ I.__._£.} WA'ITi\1fllTOI' BUtU)tNG AND &AFf!TY .l\)I NOii~ F~ ~l,T Wl$ i.~S.CA llC1012 MAE!E\..Ct<II-NG Pf\li'.~ .JO~~-J~P~ CORINA R. A!.ARCON ilODNEV I.. OIAMOND 811.l f;'HRllCH National Cooler Corporati<m 420 East Arrow H1"''Y· San Dimas, CA 91701 Attn: Chun Lee (909) 592~8830 CALIFORNIA RICHARO J. RIOROA M"VQR RECEIVEO .] !ANO t 2001 . ~AT!ONt'.L C0Ot£R ANDRfiW A . .AOEIJAAN ~L W.HA4!1R WAL 1Ei:t R. iCRUKOW l:l(B;1JTM; l;ll'l"Qlfi RESEARCH REPORT: RR 24553 (CSl #13030) Expires: February 1, 2003 GE.'l\iERAL APPROVAL -Renewal -National Cooler Cotporation Prefabricated Model 200 Refrigeration Panels for Walk-In Cooler:. ond Freezers. J)ETAU,S The panels consist of 3 ½" to 6" thick soft foam or wood.en frames with foamed-in-place rigid poly- Ul'¢thane insulation manufactured by Unh'~rsa.1 Polymer Corp. and designated as Maxccl 7 50. The skins are fabricated from 26-gage galvanixed steel with a minimum yield strensth 33 ksi. The panels are held together by use of cam-locking devices alor.g the e-dgc::i of the panels. Access holes for thesl! devices are cover1:d with metal p!ugs. Ffame Spre&d aod Smoke Density ratings per ASTM E84 are 25 and 395, 1,espe,;.'tively, for the foru11 (tested alone) and 15 and 70, respecti"ely, for the foam with the skin described abo\'e. Density of the foam is 2.5 pcf. The ponels may bi;, w.ed as toad beatj.ng walls, roof pan~is, shear walls, and diaphragms. However, fasteners for shear 111wl uplift. anchorage loads pm:p~ndkular to the w.a!!~ at fo-t: wp and bottom, and other toads not specified shall be designed for each job. National Cooler Corpontion freestanding w»lk•m coolers ~mi fn:ezen coostruded of vaods described it.bovt &tie approved subject to the following conditions: L Use oftlle panels shall bl.l limitl;ld LO locarlons where ·combustible construction is permitted by the 1999 Los Anieles City Building Code. 2. The panels shaU be fabricated in a shop ofa licensed fabricator app1vvtd by the Los Angeles Cily Building Department. F'.11brication in unHoense<l shopi will i.'1valida~e this_approva.l. 3. The panel fow11 shall be separated froari 1M fO(Jffi .in which it is Joci\.ted· and from the interior of the cooler and freezer by ½dinch thick gypsum wallboard or other approvtd thermal battier mateniru havrng a.n index of 15 wh~n tested in accordanee with UBC RR 24553 P~gl-' l of4 p.13 Mar 28 01 12:35p Sent By-: NATION.AL COOLER; HAGGERTY REFRIGERATION 619 670 Mar-28·01 3:25PM; 6690 9095924839; Nllltional Cooler Coiporation RE: ~ii£ioillli Coo\~r Coqi..tfition Prelilbrlcaled Model 200 Refriseniio1\ Paneli ror Wu!k-ln Coolcn am! Pro~ ri1Ht: , ..,, , v Standard No., 26-2. Exceplio1111 land 5 of the 1996 Los Angeles City Building Code, Section 2602.4 may be udlized where applicable. 4. Compiete plans and calculations, signed aoo stamped by a civil or structural engineer or arcbilect registereu in the Stat= of California, shall be submitted to tbe Structural Plan Check for their approval for each jot,. . 5. An approved fire retardant roof covering (Class O Au ur ''B"} shall be placed over the r,,mels wilen used as exterior roor panels. 6. A sep1m1te approval from the BlectricaJ Testing Laboratory shall be required for electrical installations wi1hin the paneJs. 1. Oesign of building utilizing the p;me:ts shall be in $Ccordance whb the n,quirem1:nls of the 1992 Los Angele$ City Building Code and tJw design data specified below; A. ~Panel Height Limitation (feet) and Matlmum Concentric Axial Loads (PLF); 'Nlk!inesv lt11wi..~ lb11t1 ... l'loncb Pllstll I {241 iblfl'i )~ Ill' !O' : 4•• 16' l:t' ~ , . . :,• lll' 16' ~-)¼" n· It\' o· 24' :20' B. Maximum Allowable Loads for Roof or Celling Panels lilil!!I l • 3.Stn. 10' 16.6 11' )i,!', 14' 5.5 Ui' 6.3 1~·-S. I 20' 4l I ,.4i.,, IB.St 13.l 9,7 7.4 ,.s 4.8 i • Sin. 'll.7 111,, 12,1 ll:t 1.1. 6.0 RR 24;'§$3 Page 2 of 4 Mulmalal As&,11-d lPl,11\ ,00 ,00 500 SOIi -- 300 I., !.5ln. 16.0 :to.a . ll,l 10.:1 8,1) D,6 , .. ,tin 1U IU 14.S 11.J a.s ,.1 p. 14 Mar 29 01 12:3?p sent By: NATIONiU COOLER; i ; HAGGERTY REFRIGERATION 618 670 6690 p,15 9095924839; Mar-28-01 3:25PM; Pagl! 15/16 (i) ' ti .. •• ;,, Nal1011al Cooler CorpQf&tion Ril: National Cooler Corpoia1loo Prdabric.slted Modi:! 200 ReJrigera,ion Panels for Walk-In Cooh:ro 1111d Fieeur, C. Ma;ii.imum Allowable Shear Load of Wall Panels (PLF); .[ D. Maximum allowable diaphragm shear shall be limited to 80 lbfn with the rnai.imum diaphragm span lo depth ratio of 2: l. The panels shall be continuous between exterior shear walls and shall not contain any openings or holc.s. E. Ceiling p11~I to wall panel connections are made with"~· dia. lag screws, 24 ga. galv. continuace cap angles, and ¼ • dia. x. I • long screws (see attached drawing). Panel to concrete slab connections arc made with 1 'h" x HP l( 16 ga. galv. continuace aagle with WI K diameter K l 1h " long screws-to panel and !4 dia. drive (expan&lon) anchors to concu:to, Spacing of conneccions shall be calculaaed for each job but not less 11'1.an two per width of panel. (Widi~ of panel= 46½"). Accurate alignment of adjacent panels is required for satisfactory workability, F. Ma.ti~um Allowable Loading for 1hc: Cam-Locking Device~; Tension 01ralld to 001111 IB,,. Sheu Blunt lenalrudllllll l'dan of ,....,.J tn J1"c1lon om,{l;l 111 Jlllnel ~M. 8. Locations of conn~tors must be detailed on approved plans. 9. Allowable loadt: for shearr walls and diaphraims are not applicable to buildings incorporating structural steel framing. 10. No increase in allowable stre11sc:1 is allowed tor the values indicated above for short duration of lomds due to wind or seismic forces. 11. All design values and methods not included in this report shall be in accordance with requirements of the l996 Los A11geles City Building Code. RR 24553 Page3n(4 618 670 6690 Mar 29 0 1 12: 3Sp .,,s~rit By: NATIONAL COOLERi HAGGERTY REFRIGERATION 9095924839; Mar-28·01 3:25PM; Page 16/16 National Coolea-Corporation RB: Nalkm! Cooler Carporlitlva PatMricated Model 200 Re!lip11.tlou hAWz 1br Wftlk·la Coolon mt Plm'.ffl DISCUSSION The clerir:a! modification is to change 1he eontact pmon. The appnmal le ba11Cd 011 cescs on the foam per requirement# of Sec. 91.2602 of the 1996 lA1 Angele. City Bullding Codev uw ooncructed ln accordlmre with ASTM E-84 oo ~ ~d paneillw and load tem conducted In~ with ASTM E-Tl. Addre&!leC to whom ttots Rcseaiich Report is Issued lm mpooaib~ for providing ooples of itr OO~J!letei with 'ID.I' ai.r.wmmenta l9dlcau,g, u, ~i~o englDtil!lll'B ud lruHdm l.lJ!Jins Items approved hereJn En ~ip or eoa1stnledon whldl must be appmmi by Depanm11mt of BuUdiiii end Safety Engineers and Jnip~wrs. Thill pnend ,wrowi uf w ~lm1i al=mete ro 1.hc Code lsoo!y vdld wbere m cngtneer amllor i~r of ihts Dep:anrmmt has determined that all condidoM of this Appmnl have bes.m n~t in the project Jn which Jc is w ~ used. VEUAN CHOV I Chief Er11ineering Ra,garch Secaion ~iuc:Ull ~,.o llMt-ff 1"!1~.lnitlll.,,_,,UHl2.~.f Attachments: Panel Connection Detail ( I Pase). RR 24553 PllP!'! 4 af-4 p. 16 ., . 6690 Mar 29 O 1 1 2: 14p HAGGERTY REFRIGERATION 9095924839; 619 670 Mar-28-01 3:21PM; t·«ye " Sent By: NAflONAL COOLER; \'()T11,,~,,d1xmln,,<',/,,111.\f1kF~C70Rl \II T/.HS)'if(\I ,.,, ,,,,1,, lf./ \T ----. APPROVAL REPORT MAXIMUM 5-1/2 in. (140 mm) THICK ·NATIONAL COOLER INSULA.TED _WOOD FRAME WALK-IN COOLER PANELS PRODUCED WI.TH MINIMUM 26 GA. GALVANIZED STEEL FACERS AND VULTAFOAM XR-1149-S POLYURETHANE FOAM SYSTEM Prepared For: NATIONAL COOLER CORPORATION 420 EAST ARROW HIGHWAY SAN DIMAS, CALIFORNIA 91773 3006483 Class 4880 Date: June 5. 2000 FACTORY f\.1UTUAL \ - Factory Mutual Re11earch i 15\ Br>Ston,Providence Turnpike P.0 80)( 9102 Nor.11000. MA 02062 IT'; l_',./ p.2 ? • _Mar 2S 01 l2:l 4 p:;, Sent By: NA f1 ONAL COOLEJl j HAGGERTY REFRIGERATION 619 670 Mar-28-01 3:21PM; F:i.C'TORY l\,1UTlJ.\L Factory Mutual Re5earcn ns, 8os101'\-Pro111dencc Turnp1~e p O 8011 9102 Norwood. MA 02062 9095924839; 6690 Yage .., 3006483 (Class 4880) June 5, 2000 MAXIMUM 5-1/2 in. (140 mm} ThJCK NATIONAL COOLER lNSULA TED WOOD FRAME WALK-IN COOLER PANELS PRODUCED W!TH MINIMUM 2$ GA. GALVANIZED STEEL FACERS AND VUL TAFOAM XR-1149-S POLYURETHANE FOAM SYSTEM INTRODUCTION FROM NATiONAL COOLER CORPORA T10N 420 EAST ARROW HIGHWAY SAN DiMAS. CALIFORNIA 91773 1. 1 Na1ional Cooler Corporation submittea their m~ulated wood frame wa!k-1n cooler panels with minimum 26 ga. {minimum 0.0172 in. (0.44 mm} base steel thickness] pttmted (optional} galvanized steel facers and max1mum5•1/5 in. (140 mm> thick polyurethane foam cores produced with General latex Vultafoam XR-1149-S polyurethane foam 1nsul~tion system to determine if they meet Facto1y Mutual Resaarch Standard 4880 (1994) Approval requirements for Class 1 tire cla:.sification to a maximum height of 30 ft (9.1 m) i. 2 Examination mc!uded flammability characterization using the Factory Mutual Research SO kW Scale Flarnrnab1l1ty Apparatus and small scale foam iosulation characteritatIon testing (ASTM 0482, ASTM 01622. ASiM D'l929, ASTh1 E84 and ASTM E.711} of polyurethane loam core specimens removed from sample insulated walk-in cooler panels and a 'Uniform 8uilolng Code Stand~rd No. 26-3 formerly (17-5} room tire test of finished insulated walk-111 cooler panels. 1.3 Tests ~howth~t ma:.c:imum 5.112 in. (140 mm) thick N'3tional Coolerrnsulated wood frame walk-in cooler panels with minimum 26 9a. {minimum 0.0172 in. (0.44 mm) base st~el thic!mess) pain1ed (optional) galvanized steel facers produced using the Vultafoam XR-1149-S polyurethane foam insulallon system. as tested, maetthe Factory Mutual Rese;lrch Standard 4880 (1994) Approval requiremi::Mts for Class 1 fire classification to a maximum height of 30 ft (9.1 rn) when installed as specified in the CONCLUSIONS of this report. It MATERIALS TESTED 2.1 Sample insulated wall and celling panels were 5-1/2 in. (140 mm) thick National Cooler wood frame walk-in cooler panels with 26 ga. (base steel 0.0179 in. (0.45 mm) thick} galvanized steel facers painted white with three cam locks per 8 ft (2.4 m) panel edge. Sample panels were fabricated using General Latex Vultafoam XR-1149-S polyurethane foam insulation system and nominal 2 by 6 I 1-1/2 by 5·· 112 in. (38 by 140 mm) wood ra!ls. Sample panel fabrication was wi'lnessed by a representative of Factory Mutual Research on February 7, 2000 at the National Cooler Corporation manufacturing facility In San Dimas., CA. Where required for testing. the galv.rniZed steel facers wera removed from the sample panels and the foam cores cut to size by National Cooler Corporation personnel. p.3 Mar 29 01 12:15p Sent ay: NATIO•-IAL COOLER; Page 2 of 10 HAGGERTY REFRIGERATION 61S 670 Mar-28-01 3:22PM; 9095924839; 3005483 2.2 •Jultafoam XR-1149-S polyurethane foam 1nsuia11on sy!.tem consists of a polyol :s component) and an isocyanate {A component) wl11ch are mixed together at 1_he ma_r.ufactunng faciiity of Na11orial Cooler Corporahon to produce the polyurethane foam insulating core of Approved Netiol'\31 Cooler insulated wood frame wa)k .. m cooler panels. 2.2.1 The 1se<:yanate (A component) 1s a polymenc oiphenylmetnane diisocyanate (MDI). The identity and specifications are 011 file at Factory Mutual Rese~rct1 2.2.2 The poiyol (8 cornponen1) Is a mixture of polyols, fire re1ardants, surfactant catalysts. s.t.abiltz:er and blowh,g agents. The 8 component was manufactured under the Factory Mutual Re3earch Facilities a.no Procedures Audit program as evidenced by a Factory Mutual Research Approval iabel. ihe formulation is on file at Factory Mutual Research, Ill TESTS AND PROCEDURES 3.1 Tes!s conducted were as re::iuired to qualify maximum 5-112 in (140 mm) thicK i1sulaied wan and ceiling panels with rnin1rnum 26 ga. [minimum G.0172 in. (0.44 mm) base steel thicl<1,essJ p.i1inted (optional} galvanized steel fac~rs aM polyurethane foam cores for Class 1 fire r;fassification to a maximum height of 30 ft (9 1 m) under Factory Mutual Research Standard 4880 (1994) 3.2, 1 A series of measurements wai;made in the Factory Mutual Research 50 kW Scale Flammabiiity Apparatus to determine the materiai ftarnm$tlility propertie::; "Of pol>·urethane: foam panel cores produced with tne Vultafoam XR-1149-.S polyurethane foam insulation system. 3.2.2 The eritieal heat flux for ignition (q",.,) and the thermal response parameter {TRP) were determined by e>tposing the coated surfaces. of.several 5pec1mens to known radiant ti~at fh.a,-es and recording the time to piloted ignition. The irwer$e square root of th~ time to ignition was plotted against the applied external radi9nt heat flux. "The intercept on rrie applied heat t!u)( axis is defined as the c1·it1cal heat flux for 1gnifo1n (the value of the exmmal heat flux at or below wh1c~1 the sampl-& c~n no longer achieve piloted igr1itkm during the 15 min.ite exposure}, The inv&rse of the slope at large external heat fluxes i11r tile thermal re$ponse param$t&r {a measure of (he, thermal inertia Qf the material). 3.2:3 The c:hemical Meat of combustion (c.H111} and Che effective heal of 9asifieat1on (l~) were determ1ne0 by meG1surlng the sample mass loss and heat generation rate history duong exposure ot a specimen to an extt.rnaf heat flux of 50 !t.W/m1. The chemical heat of combustion was ootained oy measuring the chemic~! heat release rate by CO/CO2 generation al the appiied external heat f!Ul<, time Integrating 10 obtain the to\af energy released and dividing by 1he total mass lost The ~ff~ctive heat of gasificaiion was obtained from the chemical heat release rate, me chemical. heat of combustion and ~he net heat flux which was assumed to ~e the difference between e"Xtamal heat tl1;x and the critical heat flux for ignition. 3.2.4 The convective flame spread perameter (fSF\) was dete1min@d from the chemical heal Of combustion, effective heat of 9asif1eation. net heat flux and the thermal response parameter. Mar 29 01 12:18p Sent By: NATIONAL COOLER; 300648~ HAGGERTY REFRIGERATION 619 670 Mar-28·01 3:22PM; 9095924639; ~ACTORY MU1UAL RESEARCH Page:, of 10 :J.2.5 Performance in the Factory M1.1tua1 Research 50 kW Scale Flammability Apparatus is acceptabie if the convect1ve fiarne spread parameti,r (FSP,) for the thermoset plastie foam core of an msutated wall and ceiling panel i$ less than or equal to O 39 s·111. A FSP" of O 39 s· 112 ~r less for t11e thermoset plastic foam cores of insulated steel clad wall and ceiling panels ~1as been found to correlate with the successful performance of ttiermoset plastic insulated steel clad waf! and ceiling panels m the Facto"ry Mutual Researcl'l 25 ft (7.6 m) High Corner Test 3.3 Room Fire Test 3.3, 1 ~ room fire test was condu<;ted in accordance with Uniform Building Corle Standard No. 26-J (torrnerfy 17-5) "Room Fire Test Standard for !ntenor of Foam Plastic Systems" 3.3.2 The room fire te1St was conducted 10 a room sneathed on the ceiling and all tour walls with glass fiber faced gyps4m board secured to wood framing. A2ft61n. (760 mm) wide by 7 ft o in. (2135 mm) high door was located ii'\ one 8 by 8 ft (2440 ':JY 2440 mm) wall (front). Sample wall panels were installed vertically on the 8 by 8 ft (~440 by 2440 mm) wall opposite the door (back) and the first 8 ft (2440 mm) of the adjacent ,2 by 8 ft (3660 by 2440 mm) wail (left). Sample ceiling panels were inst~lfed on the first e ft (2440 mm) of the 8 ft (2440 mm) high ceiling adjacent to the ieft and back walls parallel to the 6 ft (2440 mm) dimension. Test panels were bolted ttirough both facers to the wood framing behirn:l the !jiypsum sheathing with 3/8 in. (~.5 mm} steel lag bolts as il'ldiceted in 4.2. Panel side joints were cam lock but\ joints with plastic gaskets, The finished interior of the room after sample installation was 12 ft (3660 mrn) long by 8 ft {2440 mm) wide by 6 ft (2440 rnm) high, All test panels were ir.stailed by Factory Mutual Research personnel. 3.3.3 The exposure fire was a 15 by 15in. {3SOby 380mm} 32.0 lb. {14 5 kg) crib of 1-1/2 in. (38 mrn) square Douglas fir sticks conditioned to a moisture content of 6.8% placed at the intersection of the sample co\lered walls 1 in. (25 mm} from the interior of the sample panels and J in. (76 mm} above the noncomtiustible floor. The exposure fire was ignited using "I lb. (0.45 kg) of shredded wood excelsior and 4 oz. (0., 2 r) of ethanol. 3.3.4 The exposure fire was removed from the corner locat:on 15 minutes afrer 1gnit1on and extinguished with water. Flaming on sample panel surfaces or at sample panel joints was extiriguished witn a fine water spray after the exposure fire was exttn9uis11ed. 3.3.5 A videc tepe of the room fire test was taken through the door oppos:te the exposure fire. Temperature readings were taken at 1 second intervals us:ng thermocouples located 3, 5 and 7 ft {915, 1525 and 2135 mm) above the flopr 3 in. (76 mm) from the adjacent interior wall surfaces above the e)(posure fire and 1 in. below the ceiling at the center of the 8 by 6 tt (2440 by 2440 mm) sample ceiling area. 3. 3.5 Performance in the ,oom fire test is satisfactory if charring of the foam plastic panel core does not extend to the outer extremities of the test area within 15 minutes of the ignition of the excelsior and smoke levels generated during the lest are not exr.:essive. Oiscotoralion exten<iing up to i/4 in (8.4 1nm) into the foam plastic ls net considered to be charnrig. 3.4 SYrfice Burning Characteri§.tics The surface bumin9 characteriatics of polyurethane foam panel cores produced from the Vultatoam XR-1149-S polyurethane foam 111:&ulation system were determined in accordance with AS1"M E84-99, Stat'\dard Test Metnod for Surface Burning Characteristics of Building Materials, p.5 _Mar 28 01 12:20p Sent By: NA1IONAJ. COOLER; HAGGERTY REFRIGERATION 619 670 Uar-28 01 3:23PM; 6690 .,.,.~ Page 4 of 10 fA::1·of1Y MUTlJAI. 11!:SEARC~ /(c:,. 3006483 '::;_'...? 3,5 Heat of Combustion The heat of combu:.-tion of polyurethane foam panel corf:s produced from tne Vt:!latoam XR-1149-S polyurethane foam insulation system was determmed 111 a:.~cordance 1111th ASTM Eii 1-87(1992), Standard Test Metnod for Gross Calorific Value of Refuse Oerivec Fuel by the Bomb Calorimeter 3.6 LgniliQD ProQef!ies The ignition properties of polyurethane foam panel cores produced from the \/u!tafoam XR-1149-S polyurethane foam insuiariori sy$ten, wl$ra. determined in ac1;ordance with ASTM 01929-96, Standard Test Method for Determining Ignition Properties of Plastics, 3.7 !fIDition Residue The ,gnition residue of po!yurelhi:l!1e foam panei cores prodvced from the Vultafoam XR-1 14 9-S polyurethane foam insulation system was determined in accordance with AS TM 0482 · 95. Standard Test Meu,od for ~sh from Petroleum Products. 3.8 &Jparen1 Density The apparent density of polyuretnane foam panel cores pro~uced trom the Vultafoam XR-1149-S polyurethane foam insulation system was det~rmmed in lilccordance with t\STM D1622-Sl8. Standard Test Method for Apparent Oensrty of Rigid Cellular Plastics. IV TEST SAMPLES 4. 1 Flammability_Cl-Js~~-n Test Specimen~ A foam coue sample wlth fcicer-s remo11ed produced 1ising the Vultafoarn XR-1149 polyurethane foam system under ,H 1X5A3.AM was cut into 4 by 4 in. (102 by 102 mm) tesr specimens. Each specimen was coated.with a high absorptivity seieelive black coating pr:or to placement in rhe sample holder of the Factory Mutual Research 50 kW Seate Flarnniabihly Apparatus. 4.2 BQQ.m.Flre Test Samples 4.:2.1 Two 47 by 95 in. (1195 by 2440 mm), t11,10 24 by 96 (610 by 2440 mm}. one 23 by 96 (58!:-by 2440 mm) and one 32 by 96 (815 by 2440 mm) ffabneat&d into a corner panel with one mtenor 1 ,n. (25 mm) and one intenor Z6 in. (660 mm} leg} sample wall panels and one 47 by 101-1/2 in {1195 by2580 mm,, one 32 by 101-112 in. (615 by 2580 mm) and one 23 by 101- 112 in. (585 by 2580 mm} sample ceiling panels produced with the Vultafoam XR-1149-S polyurethane foam insulation system as described in 2.1 above were supplied. 4.2.2 The fabricated corner panel (4 bolts}, one 47 in. {1195 mm) wide wall panel (6 bolts) arid the Z3 in. (585 mm) wide watt panit! (4 bolts) were inst.tiled vertically fn::irn left to right along the back wall of the test room and secured to each oth~r wlth the three cam locks in each WQOd side rrail at each vertical panel joint. The other47 in, (1195 mm)widawall panel (6 bolts) and !he two 24 in. (610 mm) wide wall panels {4 bolts each) were installed vertically from back to frot'lt cm thEi left wall of the te:Jt room end sei:1.1red to esc:h olher with the three cam locks in aaoh wood side rail st each vertical panel joint. Mar 2S Dl 12:23p Sent By: NATlONAL COOLER; H9GGERTY REPRIGERATION 9,)95924839 i FACTO~V MVTlJAL ReSEARCH 819 670 Mar-28-01 3:Z3~M; 66S0 f "\.4 .... Page 5 of 10 4 2.3 The 32 in (815 mm) wide-ceiling panel (4 bo1tsj. the 47 111 (1195 mm1 wide ceiling pane! (6 bolts} and the 23 In. (585 mm) wide ce1l1ng panel (4 bolts) were installed fron-' back to front on (he ceiling of 1he test room parallel to the 8 ft (2.4 m) 1es1 room dimension Three lag noits :hro;,;gh each end and side rail of the ceiling panels into the to~ rails of the wall panels secured ,he ee•.ling panels to the wall par.els. 4.3 ~,!!llilCe Burning Characteristics Test §P§'.C:.,tn1ens Three 23 1n, (585 rnr,1) by 24 ft. {7.3 m) test specimens were prepareo. Each consist.ed of three 4 in. (102 mm) Uiick by 2~ in. (585 mm) wide by 8 ft. (2.44 m) long poiyurethane .. ~ore foam samples with tacers removed produeM wfth the Vultafoam XR-i 149-$ polyurethane ioam insulatio" system. Each spr:icimen was conditioned to constant mass at 73.4;:.;S.0°F (23. 0±2 .8"'C) and 50:t5% relative humidi1y pnor to installation on the ledges of the ASTM ES4 lunne! furnace 4.4 H.~~l,.9f Cqn;~us-tion Test Specimens Test specimens were removed from a4 tn. ('102 mm) !hick by 2:3 m (585 mm) w,de by S ft (2.44 m) iong polyurethane mre foam sample with facers removed pmduceo witl1 the Vultafoam XR-1149-S polyurethane foam insulation system .. 4.5 lgni!ion P'rogerties Test Sg~dm~ns iest specimens were removed from the $ame polyurethaM core loam sarrple described 1n 4 4 .above and sent to VTEC l..abOratorias, Inc .. Test specimens were removed from the same polyuretl'lane core foam sample c!e1:,ciibed in 4.-4 above. One of the test specimens described in 4.3 above was measured and weighed to aetermine apparent density, ~ V RESULTS 5.1 fls_immaoiu.tY. Char~terizjtion (from J.!. 1X5A3.AM witt1 perm1ss1on; The materi<l!l flammability properties of the tesf specimens described in 4. 1 above are given below along with the C!eas 1 limits. aH!',/1 L~ q"<t TRP f:'SPC (kJ/g) (kJ/g) (l<W/m?) (kW/m2s·112} (s·'/2) \::'ultgf,oa.rn M..--.11~ 16.0 49 20 100 0 21 0.39 p.7 (I'. ~- .l''lar 2.9 01 12: 24p Sent By: NAHONAL COOLER; HAGGERTY REFRIGERATION 619 670 Mar-28-01 3:23~M; 9095924839j Page t3 of 10 FACTOl'lY Ml.iTIJA. RESEARCH 5 2 ,Bgom Fm? TeM 5 2. 1 Visual observations during the test pen11d were as follows. _rime\mll":sec.} Obwv~Qn 0:00 lgri1!ion of exposure f1:e. 6890 )006483 1 :25 exµosure flarn$s to approi-:. 5 ft t 1500 mm) above floor 1 :45 Exoosure flames fo approx. 7 ft (2 i 00 mm) above floor i :55 Some buckling of panel facers 1mmedi3tely behmd exposure fire to approx 6 fl {1800 mm above floor. 2: 10 !;rposvre flames licking to ceiling. 2.20 Cori!inuect buckling of panel f.acers immediately b@hmd exposure fire. 3:00 Ce1l1ng panel lacers immediately abov~ exposure fire $tan1ng to buck.le. 3 1t) Flaming to 1 to 2 ft {300 to 600 mm_l along botn eaves. 3:45 Flaming to t to 2 ft {300 lo 600 mm) along both eaves, very light smoKe lo approx. 1 ft (300 mm) below the lop of tne door frame, 5-15 Flaming to 2 to 3 ft {800 to 900 mm) along both eaves, very light smoke to approx. 1-1/2 ft (450 mm) below the top orn,e door frame. 5:50 Wall board iacir'lg 1mmed1ately to tne right of exposure fire ignites. 6:30 Flaming to approx. 3 ft (900 mm) along both eave!, light smoke to approx. 1-1/2 fl (450 mm} below the top ot the door frame. flaming at bottom of wall panels at back wall at the edge of the wall board on the floor continues intermittently. 8' 15 Fiamir19 to 2 to 3 ft (600 to $00 mm} along both eaves. light to moderate smoke to approx. 1~ 112 ft (450 mm) below the rop of the door frame. 9:30 Flaming to 2 to 3 ft (600 to 900 mm} along botl'l eaves, light to moderate smoke to approx. 1. 112 ft {-450 mm) below the top of the door frame. g:45 Flaming at 1 ft (300 mm) shove fie-or in first ioint past exposcire fire on back waif. $Om~ flames at wall/floor intersection on left wall in tron1 or exposure fire, some naming a wall/floor intersection 3 to 4 ft (900 to 1200 mm) from exposure fire on back wall. 1 'i: 10 Flaming to approx 3 ft (900 mm} along both eaves. some sagging ot ce,11n9 pane! face rs immeaiateiy above exposure fire, ligl'lt to medium smoke to approx. 1-112 ft (450 mm) below the top of1he door frame. 12: 1 o Flaming to approx. 3 ft (900 mmj along both eave,, light to medium smoke to approit 1·1/2 ft (450 mm) below the top of the ooor frame 13.15 Flaming to approx. 3 f1 (900 mm} aiong both eaves. s,;,me flaming m the comer joint near the ceiling, light to medium smoke to approx. 1-1/2 ft ( 450 mm) below the top of the door frame. 14: 15 Flaming to approx. 3 ft (900 mm) along both eaves, light to medium smoke to approx. '1¥1/2 ft {450 rnm} below the top of trte door frame, small areas of flaming at walUfloor intersection along both wal(s 10 1 to 1-112 ft (300 to 450 mm) out from exposure fire. flaming at lowest eamlock hole at the first jomt on the back wall from the comer. 15:00 Test terminaled, expos•.J(e fire and sample panels extinguished with water. 5.2.2 Upon examination of tne test panels after the room fire test. no ~harring of the polyuretharn:i foam core was observed at the extremities of the test panel area. 5,2.3 Smoke levels generated by the test pa1,els. during the test period were not considered excessive. p.8 (i Mar 29 Sent Gy: 01 12:2Sp HAGGERTY REFRIGERATION 819 670 8690 NA TI ONAL COOLER; 9095924839; r,1ar-2s-01 3:24PM; P-age 3006483 FAC,:TORY MUTtJAL. AF!~F.AR('";l't Page 7 ot 10 S. 2.4 See Appendix A for a record of temperatures recorded a! the !her mocouple locations outlined 1n 3.3.5 above. 5.2.5 A v;deolape (8 mm format) is on file 1n the Technical lnformauon Csnte1 al Factory Mutual Research under J_l 3006483. 5 3 Surfc:ce Burning Characteristics• The surface burning characteristics of1he test specimens descnbed in 4.3 above were as fellows Specimen 1 2 3 Average Flame Spreag Index" 22.9 20.3 20.0 20 S!]Oke Density Index· 245 151 133 180 · l hese numerical Flame Spread and Smoke Density indexes do not def me tl'le hazard present¢d'by this ar any otl"ier matertal under actual fire conditions. 5.4 Heat of Comb!,ls(mn• The heat of combustion of t~e test specimen described 1n 4.4 above was 10,C.50 Btu!lb (23 4 MJ/kg) 5 5 l9n1tiM Progerties' (from VTEC # 100-1133. April 1 o. 2000) The ignition properties ot the test specimens described 1n -4. 5 above were as follow$: Flash-ignition temperature Self-;gnition temperature 5.6 !.rul[tion Residue~ 851 °F \ 455°C) 923°F (4~5QC) The r~sidue left afterigmhon of the test specimen described in 4.6 above was 0.4% by weight. 5. / Apparent Den§it)t The apparent density of the test specimen described in 4.7 above was 2.3 lb/W (37 ~ These tests are conducted 10 sati5fy code requirementa or for identification purposes_ Factory Mutual Research places no limits on the values obtained_ VI CONCLUSIONS 6.1 Test results indicate that National Coolerins1.ilatedwood frame wa1k-in cooler panels with minimum 26 ga. [m1t1imum 0.0172 in. (0.44 mm} base steel thickness) painted (optional) galvanized steel fec:ers and ma}(imum 5-1 /2 in. ( 140 mm) thick polyurethane foam cores prod1Jced p.S 9/16 ~ bi .,/ Mar 29 Cl l2:2Bp sent By: NAT:ONAL COOLER, HAGGERTY REFRIGERATION 619 670 Mt~l'-20·Oi 3:24PMi 6690 9095924839; I lol";::1'"" Page 8 ,,t 10 FACTDFlV MUTUAL RESf..AflCH 3006483 with the Vultafoam XR,1149-S polyurethane foam 1nsutat1on system meet the Factor/ M~t~al Researcn St.mdard 4880 (1994) requirements for Class 1 Approval of ins1Jlated wall and ca,hng panels to the maxin1um installed heignt of 30 ft (9 1 m} 6.2 Panel joints are to be sealed with silicone sealant as the panels are installed 6 3 Tests show 1) that the panels in and of themselves would not c:reate a need to·· automatic sprinklers and 2) that the panels would be acceptable rn a combustible occupar,cy protected by aulomatic sprinklers as defined by FM Global Property Loss Prevention Stan<:l~rds 6.4 The tested constructions meet the Factory Mutual Re!ie~rcn Approval cn\eria and when Approval 1s effective will be listed in tne Faciory Mutual Research Approval Guide 6.S Approvai is effective when the Approval AgrMm6=nt is signed and received by Factory Mutual Research. 6. 6 Continued Approval will depend upon satisfactory field experience and per:odic Quality Audit Inspections. 6. 7 Polyurethane foam produced from the Vultafoam XR-1149-S polyurethane foam insulation system has not been evtJluated for the toxicity of tht:l' product::. of combustion. VII MARKING 7.1 The manufacture, shall ma1k each panel or shipping unit with 1he manufacturer's name and produd trade name. In atldition, the panel or shipping unit mus! be marked With the Factory Mutual Research Approval Mark and tne words "Subject to the conditions of Approval as a Class 1 insulated wall and ceiling panel when used as described In the current edition of the Factory Mutual Research Approv~I Guide". 7.2 Markings denoting Factory Mutual ~esearch Approval shal! be applied by the manufactwreronfy within and on the premises of maniJfacturing locations that are under the Factory Mutual Research Facilities and Procedures Audit Program. 7 .3 The manufacturer agrees 1hat use of the Factory Mutual Research name or Approval Mark is sub1ect to _the conditions and limitations of lhe F'aetory Mutual Research Approval. Suoh conditions and limitations must be included in all references to Factory Mutual Research Approval. VIII MANUf::ACTURER'S RESPONS!61LIT!ES 8.1 To assure i:ompliancewith the CONCLUSiONS of this report, the manufacturer shall supply to the ,nstalle, of building owner such necessary instructions or assistance required to produce the desired performance acf11evec1 in the tests. 8 2 The manufacturer shall notify Factory Mutual Research cf any planned change in the Approved irisulated wood frame walli.-in cool et panels. prior to general sale or distribution. using Form 797. Approved Product Revision Rer;ort. '1;\ ( I . '-,/' p.10 f'! ar 2S O 1 1 2: 30f) Sent By: NA";IQNAL COOLER; 300(;483 HAGGERTY REFRIGERATION 619 670 Mar·28-01 3:24PM; 9095924839; FACTOR'/ MUTUAL RtSE'ARCH !X QUALITY AUDIT INSPECTION AND RE-EXAMINATION 6690 :-'age 11, ,1., Page 9 ot '0 ·@~. 9. 1 Re-exarniriation and m:anufact1,1ring 1nspect101'\S wilt be conducted periodically on the Approved insu!Qted wall and ceiling panels at the National Cooler Corporation manufacturing facility in San Dimas, CA to determine that the quality and uniformity of the panels 1s Ming maintained and will provide the same level of performance as or19111ally Approved. 9.2 Re-ex~mination of the Approved insulated wall and ceiling panels may be required to assess formulation changes to the fQam insulation system, panel configura!ion ch~mges or changes in field installation procedures or end-use. TECHNICAL SUPER\l!SION OF CONSTRUCTION, FIRE TESTS ANb REPORT BY: Attachment: Appendix A (1 p~ge) REPOFff REVIE.W!;O 9Y: . Gould, P.E tstant Manager, Materials Section p. l 1 ru ..... . Q_ ©Q § Test #01 National Cooler Corp. 832-6232-66 03-28-2000 ~ Job Index# 30064.83 0 (]) CD CD 0... Cl ~ !:'--~ CD •• t') Cl) -.... ~ CD a:, z: 0 H I--er: (\j L <.<; ;;;; ai: -~ lJ.J OJ t.!) ~ 1-1 '<I" 0::: Sl LL. y') w Ol !l'. g )- I- O!: w (!) (!) a: I 1169 Scans 20001 Tempe·rature Data l 1750 1500 1250 JI-< 1000 750 500 a: w IL --' ru 8 250 C') '·' -l C\J ~ ..... 0 ,__, ---------~ jrc9078_ TC:00001 -jrc907B_TC00002 -jrc9078_TC00003 ...-.. jrt907B_ TCOOOD4 "'() Ql i .... 0 s. _._ 0 .,, l> Cl ..... 0 :n ~ -< -0 !l: 1' C Ci) -! ;:, -.:: Q. l> -· .... X :i:, ):, IOI "' ,., }> JO Q 1--,.., -<l'. oz Q -t,-rr ~, i I i t it 'f~ Y i rm I I 5 -t i i I i I 1 i I f'" • !i I I i i Y 1 T I I I ft U i I f f I i i .9 11 ¼ i i , I a f I 'i i i :t "3 (;.I 0 0 (Jl l>-co (,.) en "" (\J .:0 .... ~] E L .. A -t 0 ·j 2 3 4 5 7 8 9 10 1 1 12 13 14 ·15 Minutes I I I I I -1 I I ·I I I I I I I I I I I ., ., ., ., ., ., ., ., ., ., ., V "' ,, 'ff ,,. ,- lnvitrogen Corporation 1600 Faraday Avenue·-Carlsbad, California Technical Report Code Conditions & Requirements Uniform/California Codes Analysis Hazardous Materials & Storage Operations 11 May 2001 [Rev. 1] TECHNICAL CONSULTANTS FOR COD FIRE/BUILD 4719 Palm Avenue., Lo·· Mesa, CA 91941 Tel. 619.466,6285 Tfox 619,4'66,6233 f 1 .. P-H~t 1 ~1.. .. PLui~t 1. l t )· ~l'6flN li V .I I I I I I I ·1 ·: .. I I I I I :I I I I I --1 INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS lnvitrogen Corporation 1600 Faraday Avenue -Carlsbad, California Technical Report Code Conditions & Requirements Uniform/California Codes Analysis Hazardous Materials & Storage Operations 11 May 2001 [Rev. 1] Prepa~ed by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California _ Telephone 619.466.6285 FAX 619.466.6233 EMAIL.. MaryRattan@thecoderesource.com or MaryRattan@covad.net This report is the property of Eriksen-Rattan Associates Inc. and was prepared exclusively for use by lnvitrogen Corporation for the operations described in this report. Copies of this report retained by lnvitrogen Corporation shall be utilized only by them for occupancy classification and the Uniform/California Code conditions addressed in this report. This report shall not be used for the purpose of construction for this project or any other project or for any other purpose. I ,\l\h~ I I I I- I I I I :I :I I -I -'.:] I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS TECHNICAL REPORT -OVERVIEW Eriksen-Rattan Associates Inc. · prepared this ''Technical Report" for the exclusive use of lnvitrogen Corporation [IC]. The report was prepared for tenant improvements to IC's existing operations located in an existing, fully sprinklered building at 1600 Faraday Avenue in Carlsbad, California.1 The report addresses Uniform/California Code requirements and conditions applicable to the following hazardous materials and storage operations: 2 • Hazardous Materials Operations -Control Areas 1, 2, 3: Use, storage and handling of both new and residual/waste hazardous materials associated with the manufacture of molecular biology products for gene discovery, gene cloning, gene expression and protein separation and purification, with the building divided into three [3] hazardous materials B/F1/S1 Occupancy Control Areas. • Shipping & Receiving/General Storage Conditions-Room 125: General rack and floor star.age conditions for Class I-IV non:-hazardous materials commodities and floor/palletized storage of bulk solutions manufactured on-site, with rack storage at <12' above the finished· floor and floor/palletized storage at <6' above the finished floor. 1 Existing Opera~ions: The following operations/areas are existing, previously approved conditions to which no tenant improvement changes are planned. These operations/areas are not intended to be addressed in this report as existing conditions are presumed to comply. Hazardous materials information/conditions for these areas are provided for information/reference only. ~ 103 -Facilities • 104, 105, 106, 157, 158 -Offices • 109, 112& 152-T.C. Rooms • 110 & 111 -Men's & Women's Rooms • 125 -Shipping & Receiving • 128 -Chemical Storage Room • 130 -Boiler Room • 140 & 151 -Telephone Rooms • 151 -Electrical Room • 154 -DNA Synthesis • 155 -Micro Array • 156-Lab • 160 -Janitor Closet • 163-Shop • 165-[Operations not identified on plans] • 2nd Floor, except new 342 sf 2nd floor area 2Applicable Codes: The 1997 Uniform/1998 California Codes have been used as the baseline for requirements and conditions applicable to this project. · This report is the property of Eriksen-Rattan Associates Inc. and was prepared exclusively for use by lnvitrogen Corporation for the operations described in this report. Copies of this report retained by lnvitrogen Corporation shall be utilized only by them for occupancy classification and the Uniform/California Code co.nditions addressed in this report. This report shall not be used for the purpose of construction for this project or any other project or for any other purpose. ii I I ~·I.id .1 I I I I I I I I I I I I I I I - INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS TECHNICAL REPORT -OVERVIEW The format of the report is as follows: 2.0 3.0 4.0 5.0 1 2 3 Building & Site Conditions lnvitrogen Hazardous Materials & Sto~ge Qperations .. Exhaust Ventilation/Class I, II & Ill-A Liquids -·control Area 3 [Alternate Method of Compliance] Code Analysis Attachments Hazardous Mate'rials Inventory Analysis -: .. Supplemental Information Site & Building Plans -Overview Building plans and construction docu·ments will be provided separately through MJK Architecture & Planning. Review of such plans and documents for the conditions and requirements addressed herein is outside the scope of this report. Conditions other than the hazardous materials and storage operations addressed in this report are outside the scope of this report. iii :I ;I I I I :I I \I ~~ I I ·1 . \ :,\\' I 'I ' ' ~lhol ' :I ,, I ;I ·I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS TECHNICAL REPORT -INFORMATION Questions concerning the project, plans and construction documents for this project should be directed to: MJK Architecture & Planning Michael J. Kinoshita 14388 Marianopolis Way San Diego, California 92129 Telephone 858.484.3613 FAX 858.484.6239 EMAIL mjkino@flash.net Questions concerning lnvitrogen Corporation operations should be directed to: lnvitrogen Corporation Douglas Taniguchi or Ric Longo 1600 Faraday Avenue Carlsbad, California 92008 Telephone 760.476.6820 FAX 760.476.6867 EMAIL dtaniguchi@invitrogen.com rlongo@invitrogen.com Questions concerning this report should be directed to: T Eriksen-Rattan Associates Inc. Mary Eriksen-Rattan 4179 Palm Avenue La Mesa, California 91941 Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com Discrepancies between this_ report and actual plan and field conditions are the sole responsibility of the lnvitrogen Corporation and MJK Architecture & Planning. iv I I ·I I I I I I I :1 I I I ii I '~ .. , -:I ,!:,,.J :I ii ., INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 1.0 2.0 3.0 4.0 5.0 Table3.0 1 2 3 4 5 6 7 8 9 10 11 12 13' 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 TECHNICAL REPORT / CODE REQUIREMENTS & CONDITIONS ' TABLE OF CONTENTS Scope Building & Site Conditions lnvitrogen Hazardous Materials .& Storage Conditions Exhaust Ventilation/Class I, II & 11!-A Liquids -Control Areas·1 & 3 Code Analysis Hazardous Materials & Storage Operations Occupancy & Control Area Conditions Occupancy & Control Area Separations Draft Curtains Smoke & Heat Venting Separation of Incompatible Hazardous Materials & Conditions. General Area Ventilation System Exhaust Ventilation System & Explosion Control -Class I, II & Ill-A Liquids Class 1 Product Conveying Exhaust Duct Systems -Class I, II & Ill-A Liquids Class 5 Product Conveying Exhaust Duct Systems -Corrosives -Exhausted Hoods/ Exhausted Enclosures Exhausted Hoods/Enclosures Electrical Classified Areas -Class I Flammable Liquids in Use & Transfer Egress System Liquid Transfer Operations -Hazard Ranking 3 & 4 Liquids -Control Areas 1 & 3 Piping, Valves & Fittings -Hazardous Materials & Compressed Gases Limit Controls -Hazardous Materials Spill Control, Drainage & Containment -Hazardous Materials Lighting Ignition Source Control Compressed Gases [Inert/Nonhazardous] Equipment, Machinery, Containers, Tanks, Vessels & Processes-Hazardous Materials Fire Extinguishing System Protection Portable Fire Extinguishers Material Handling & Transportation in Building -Hazardous Materials Storage Arrangements -Hazardous Materials & General Storage Approved StoraAe Cabinets -Hazardous Materials Premises Identification Water supply for Fire Sprinkler system & Fire Flow Fire Department Access Hazard Identification Signs Emergency Response, Training & Procedures Special Use Fire Department Permits &. Plans V 1-2 3 4-10· 11-12 13-47 14-47 14 15 16 16 17 18 19-20 20-23 24 24 25 26 26-27 27-29 30 30 31 31 32-33 33 34-36 37 38 3941 41-42 42 42 43 44 45-46 47 I I I I I· I I I I I I I I I I I ' I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 18 1B-1 1B-2 1C 1C-1 1C-2 10 1E 2A 28 2C 2D A-1 A-2 A-3 A-4 TECHNICAL REPORT/ CODE REQUIREMENTS & CONDITIONS· TABLE OF CONTENTS Control Area 1-RoQm 128/R~i,;iduat-Waste C_h~n:iipat Stol';;lge .. Summary & Exempt Amounts 1-5 Inventory Itemization -Alphabetical. l;ly L9catio_n & Materi~I N~ITl.e 1 Control Area 2 -RoolTl 1·40/RaW ,V,~tericll,. $to~gfJ · -.·. Summary_ & Exempt Amounts 1-14 Inventory Itemization-Alphabetical by Lo.c;:ition & Materi_al Name 1-12 Control Area 3. -_All Building-Areas~ ExcepfRoonis 128 & 140_ Summary & Exempt Amounts 1-11 Inventory Itemization-Alphabetical by L9cation & Materi!:!1. N~me_ 1-13 Building lnventory-Con~rol Arec1s.1-3 . Inventory Itemization -Alphabetical by Location & Material _Nan:ie 1-25 Definitions for Abbreviations Definitions 1 Storage Commodity Classifications 1-4 Definitions for Terms -Specific to lnvitrogen Operations 1 OSHA Regulations -Battery Charging Operations 1 1-2- Site Plan 1 Demolition Plan 1 1 s Floor Plan/Area of Tl Work 1 2n Floor Plan/Area of Tl Work 1 vi INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS TECHNICAL REPORT -TENANT IMPROVEMENTS HAZARDOUS MATERIALS & STORAGE OPERATIONS TECHNICAL REPORT -CODE REQUIREMENTS & CONDITIONS 1.0 SCOPE Eriksen-Rattan Associates Inc. prepared this "Technical Report'' for the exclusive use· of lnvitrogen Corporation [IC]. The report. was prepared for tenant improvements to IC's existing operations located in an existing, fully sprinklered building at 1600 Faraday Avenue in Carlsbad, California.1 The report addresses Uniform/California Code requirements and conditions applicable to the following hazardous materials and storage operations: 2 • Hazardous Materials Operations -Control Areas 1, 2, 3: Use, storage and handling of both new and residual/waste hazardous materials associated with the manufacture of molecular biology products for gene discovery, gene cloning, gene expression and protein separation and purification, with the building divided into three [3] hazardous materials B/F-1/S1 Occupancy Control Areas. • Shipping & Receiving/General Storage Conditions -Room 125: General rack and floor storage conditions for Class I-IV non-hazardous materials commodities and floor/palletized storage of bulk solutions manufactured on-site, with rack storage at <12' above the finished floor and floor/palletized storage at <6' above the finished floor. 1 Existing Operations: The following operations/areas are existing, previously approved conditions to which no tenant improvement changes are planned. These operations/areas are not intended to be addressed in this report as existing conditions are presumed to comply. Hazardous materials information/conditions for these areas are provided for information/reference only. • 103-Facilities • 104, 105, 106, 157, 158-Offices • 109, 112 & 152-T.C. Rooms • 11 o & 111 -Men's & Women's Rooms • 125 -Shipping & Receiving • 128 -Chemical Storage Room • -130 -Boiler Room • 140 & 151 -Telephone Rooms • 151 -Electrical Room • 154 -DNA Synthesis • 155 -Micro Array • 156-Lab • 160 -Janitor Closet • 163-Shop • 165-[Operations not identified on plans] • 2nd Floor, except new 342 sf 2nd floor area 2Applicable Codes: The 1997 Unifonn/1998 California Codes have been used as the baseline for requirements and conditions applicable to this project. This report is the property of Eriksen-Rattan Associates Inc. and was prepared exclusively for use by lnvitrogen Corporation for the operations described in this report. Copies of this report retained by lnvitrogen Corporation ,shall be utilized only by them for · occupancy classification and the Uniform/Ca/ifomia Code conditions addressed in this report. This report shall not be used' for the purpose of construction for this project or any other project or for any other purpose. TEriksen-Rattan Associates Inc. Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations 4719 Palm Avenue, La Mesa CA 91941 Cod7 Requirements & Provisions-5/11/01 [Rev.1]-Page 1 of47 I :I I I I I I I I I I I I I .I ·1 ,,:,~I -I ... , I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES A.NAL YSIS The format of the report is as follows: • Building and site conditions are described in Section 2.0. • Hazardous materials and storage operations are described in Section 3.0. • An alternate method of compliance for exhaust ventilation in some areas where Class I,, II or Ill-A Liquids are used is discussed in Section 4.0. • Code conditions and requirements are addressed Section 5.0. • Hazardous materials inventory information for both existing and tenant improvement conditions are provided in Attachment 1. · • Supplemental information is provided as Attachment 2. • Building and site plans are provided as Attachment 3. Building plans and construction documents will be provided separately through MJK Architecture & Planning. Review of such plans and documents for the conditions and requirements addressed herein is outside the scope of this report. Conditions other than the hazardous materials and storage operations addressed in this report are outside the scope of this report. TEriksen-Rattan Associates Inc. Technical Reportrrenant Improvements -Hazardous Materials & Storage Operations 4719 Palm Avenue, La Mesa CA 91941 Code Requirements & Provisions-5/11/01 [Rev. 1]-Page 2 of 47 I I I I I I 1: I I I I I I I I I . I I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 2.0 BUILDING & SITE CONDITIONS 1. Building Construction [Existing/Previously Approved] 2. Stories [Existing/Previously Approved] 3. Occupancy [Partially Existing/Previously Approved] 4. Control Areas -Hazardous Materials 5. Building Area ·[Partially Existing/Previously Approved] 6. Side Yards [Existing/Previously Approved] 7. Fire Department Vehicle Access [Existing/Previously Approved] 8. Water Supply [Existing/Previously Approved] 9. Fire Protection [Existing/Previously Approved] 10. Plans & Tl Construction Documents [Existing/Previously Approved & Tl] "f Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 + Type: 111-N +Number: 2 + Major Use: B, F1 & S1 + Minor Accessory Use: A3 [< 10% of building area and < A3 basic · allowable building area] +Number: 3 + Details: See Section 3.0. + Total: 60,553 sf • Existing: 60,233 sf • Tl Addition: 320 sf + 1st Floor: 49,598 sf +2nd Floor: • Existing: 11,635 sf • Tl Addition: 320 sf + North: >/=60' + East: >/=60' + South: >/=60' + West: >/=60' + On-Site Access Roadway: • Width: >/=20' • Unobstructed Height: >/=13.5' • Surface: Asphalt • Location: Around perimeter of building, with driveway access from Faraday Avenue at 2 locations. + Public Streets: Faraday Avenue. + On-Site Fire Hydrants: [Details not provided to ERAI.] + Public Fire Hydrants: [Details not provided to ERAI.] + Fire Department Connection: • Type: [Details not provided to ERAI.] • Location: [Details not provided to ERAI.J + Fire Sprinkler System: • Fully sprinklered building. • System design of 0.45 gpm over 3,000 sf design ~rea. +Fire Hydrants: See Item 7 . +Standpipes: None-not applicable to IC conditions. +See Attachment 3 for overview. + Refer plans submitted separately by MJK Architecture & Planning for details. Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11 /01 (Rev. 1] -Page 3 of 47 ·'I j \,~'\J ·1 ' ~ ~ l\l I ·1 1' ~ ..,\.I I ,' L'" ·1 I I ' •• u !I I. I ·I I I I I I I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 3.0 INVITROGEN HAZARDOUS MATERIALS & STORAGE OPERATIONS · lnvitrogen will use the 1600 Faraday facility for the manufacture molecular biology products [kits} for gene discovery, gene cloning, gene expression and protein separation and purification, with the nature of the kits as described below. Each kit will contain products [i.e.: solutions] that will be manufactured at the facility, with the manufacturing operations involving a combination of both hazardous and nonhazardous materials. . • Gene Discovery kits will be manufactured using isolation of RNA synthesis of cDNA, cloning of genes and the expression of proteins. • Gene Cloning kits will be manufactured to manipulate recombinant genes and plasma isolation and purification: Gene Expression kits may also include kits for bacterial transformation and the production and characterization of recombinant proteins from bacterial yeast, insect and mammalian cells. · • Gene Expression kits will contain DNA and viral vectors to express genes, with the viral vectors derived from n_ovel bacterial strains (non-pathogenic) and insect and mammalian cell lines. • Protein Separation kits will corytain reagents for detection and separation of protections, stains that detect proteins and fluorescent or chemiluminescent reagents for protein visualization of polymer membranes. The building will be divided into three [3] B/F11,S1 Occupancy hazardous materials Control Areas as listed below, with the operations within each Control Area described in Table 3.0. A min(?_r accessory-use area [A-3 Occupancy lunch room] will be located within Control Area 3. • Control Area 1: Room 128 -Residual/Waste Chemical Storage [S-1 Occupancy] PVl t:.'11! 'l,.. • Control Area 2: Room 140 -Raw Material Storage [S-1 Occupancy] PJ4A'6t 'L • Control Area 3: Balance of Building -Manufacturing, General Storage, Shipping & Receiving and Support Operations [B, F-1, S-1 Occupancy] TEriksen-Rattan Associates Inc. Technical Reportrrenant Improvements -Hazardous Materials & Storage Operations 4719 Palm Avenue, La Mesa CA 91941 Code Requirements & Provisions -5/11/01 [Rev. 1]-Page 4 of 47 :I :I !'.:\\:I !I I :I 1~·-...IJ I ,!,. I ' ' 'M' I 'I I I, I I I I , .. ,I ... •·\- . ,, I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 1. Building Use Conditions [Partially Existing/Previously Approved] 2. Control Area 1 -Room 128 • Occupancy: • Major Uses: B, F1 & S1 • Minor Accessory Use: A3 [Lunch Room 101] • Hazardous Materials Control Areas: Three [3]. • Operations: * Offices; administrative, employee areas. * Facilities and ·site support utilities/operations * Manufacturing and manufacturing support operations. * Miscellaneous & general storage -no high-piled combustible storage conditions. • Hazardous Materials: See Items 2-4. · • General Storage: See Item 5. • Occupancy: S-1 • Location: Room 128 -Existing Chemical Storage Room [Residual/Waste Materials Storage] • Hazardous Materials: • Inventory: See Attachment 1A. • Physical Hazard Materials: * Flammable Liquids 1-B * Oxidizers 1 • Health Hazard Materials: * Carcinogens * Corrosives * Irritants * Other Health Hazards • Storage Conditions/Methods: * Vessels: 30-60 gallon drums/containers * Floor Storage: 1 drum/container high * Cabinets: Storage in approved c;abinets -either Oxidizers or Flammable Liquids 1-B [separation of incompatible materials]. • Use Conditions: * Transfer: Manual transfer of residual/waste materials into storage/receiver vessels. * l.iquids: </=20 liters [5.3 gallons] transferred at any time. * Solids: </=1 O pounds transferred at any time. • Exhaust Ventilation System -Flammable Liquids 1-B Transfer Operations: • General/area exhaust ventilation at >/=1 cfm per sf of floor area will be provided in the room. • See Attachment 2D for nonflammable vapor exhaust conditions for Class I Flammable Liquids. T Eriksen-Rattan Associates Inc. Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations 4719 Palm Avenue, La Mesa CA 91941 Code Requirements & Provisions -5/11/01 [Rev. 1 J -Page 5 of 47 I I I 1· I 1· I I I I I, .!\,\\I I I 1- 1- .. . I I I - INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 3. Control Area 2 -Room 140 T Eriksen-Rattan Associates Inc. 4719 Palm Avenue; La Mesa CA 91941 + Occupancy: S-1 + Location: Room 140 -New Raw Material Storage Room + Hazardous Materials: • Inventory: See Attachment 1 B. • Physical Hazard Materials: * Combustible Dusts * Combustible Liquids II, Ill-A, 111-8 * Flammable Liquids I-B, I-C * Flammable Solids * Oxidizers 1, 3 * Unstable Reactives 1, 2, 3 * Water Reactives 1, 2 • Health Hazard Materials: * Carcinogens * Corrosives * Highly Toxics * Irritants * Other Health Hazards * Sensitizers * Toxics • ·storage Conditions/Meth~ds: * Liquids: <1-gallon containers to 55-gallon drums. * Solids: <1-pound to 100-pound containers * Floor Storage: 1 drum/1 pallet/1 container high · * Shelf Storage: Individual containers to <8' above the finished · floor * Cabinet Storage: The following materials stored in approved cabinets, with incompatible materials stored in different/separate cabinets: • Combustible Liquids II & Ill-A • Flammable Liquids I-B & I-C • Oxidizers 1 & 3 • Unstable Reactives 2 & 3 • Water Reactives 2 • Use Conditions: None -storage only. Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1] -Page 6 of 47 ~I )I :~ ,\.N . ,, \ .:.~ \I 1- _J INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS Table 3.0 -lnvitrogen Operations :.< .. } .. ::.t:fl .. b •. :.'..(! .. Fgiffl.itfst .. U ..... t.Jl ...... i .. ::: . U) ..... /J'! ....... ,, .. ) .. Vll.':.\}.l(!J -~= JJondit{gµs.;@(l:V ..... f ?.Jtt_:· .... .U.)< :.:::t .... : 4. Control Area 3 -All Building Areas Except Rooms 128/Control Area 1 and 140/Control Area 2 (continued on next page] T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 +Occupancy: B, F-1, S-1 +Location: lb• General: All Building Areas Except Rooms 128/Control Area 1 and r 1. 140/Control Area 2 • Hazardous Materials Operations/Locations: ( 109 -T.C. Room [Existing] [Storage & Use] V) * 118 -Bulk Solution [New] [Ul?e] · r"" * 119 -Clean Room [New] [Use] 121 -Manufacturing [New] [Storage & Use] Pl * 135 -Compcell Production Lab [New] [Storage & Use] · PL * 125 -Shipping & Receiving [Existing & New] [Finished Product Storage] 1 /*.137 -Fermentation [New] [Storage & Use] f-"-* 138-Custom Services Production Lab [New] [Storage Only] ( ~.J * 154 -DNA Synthesis [Existing] [Storage & Use] + Hazardous Materials: • Inventory: See Attachment 1 C. • Physical Hazard Materials: * Combustible Liquids II, Ill-A, 111-B * Flammable Liquids 1-8, 1-C * Flammable Solids * Inert/Nonhazardous Compressed Gases * Unstable Reactives 2, 3 * Water Reactives 1, 2 * Bulk Solution Mixtures/Room 118: May also include small amounts of Flammable Solids, Oxidizers 1, Oxidizers 3, Unstable Reactives 1] . • Health Hazard Materials: * Carcinogens * Corrosives * Highly Toxics * Irritants * Other Health Hazards * Sensitizers * Toxics • Storage Conditions/Methods: * Locations: As indicated above. See Item 5 for Room 125/Shipping & Receiving conditions/methods. * Liquids: <1-gallon to 5-gallon containers * Solids: <1-pound to 100-pound containers . * Gases: </=150-pound cylinders -upright storage on floor. * Floor Storage: 1 drum/1 pallet/1 container high * Shelf Storage: Individual containers to </=8' above the finished floor * Cabinet Storage: The following materials stored in approved cabinets, with incompatible materials stored in different/separate cabinets: . • Combustible Liquids II & Ill-A • Flammable Liquids 1-8 & 1-C • Oxidizers • Unstable Reactives 2 & 3 • Water Reactives 2 Technical Reportffenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11 /01 (Rev. 1] -Page 7 of 47 I I I ~, I I !I ;1 ii ,:;e\J I I :1 I ,, ., .. , ~·-~) . , INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS Table 3.0 -lnvitrogen Operations 4. Control Area 3 -All Building Areas Except Rooms 128/Control Area 1 and 140/Control Area 2 (continued) (continued on next page) T Eriksen-Rattan Associates Inc . 4719 Palm Avenue, La Mesa CA 91941 + Hazardous M terials.[c ntinue ]: • Use Condi · & · ns: ( * Rooms 09, 12 , tl35 137 154: t°J • Genera : ombination of closed and open system use conditions. • • Class I, II & Ill-A Liquids: Locations and use conditions for Class I, II, Ill-A Liquids as follows: p'L * 109 -T.C. Room [Existing]: * Flammable Liquids 1-8 * Closed and open system use conditions. * </=0.25 gallon in use at any time. . * Use within exhausted enclosure or exhausted fume hood. f'-*. 121 -Manufacturing [New]: * Combustible Liquids II & Ill-A, Flammable Liquids 1-8 & I-C * Closed and open system use conditions. * </=0.002 to </=1.06 gallons in use at any time. · * Use within exhausted enclosures, exhausted fume hoods and walk-in exhausted enclosures/hqods. l Ii" j * 154 -DNA Synthesis [Existing]: * Flammable Liquids 1-8 * Closed system use conditions. * </=5.3 gallons in use at any time. * Use within exhausted enclosure, exhausted fume hood or walk-in exhausted hood/enclosure. * See Attachment 20 for nonflammable vapor exhaust conditions. Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11 /01 [Rev. 1] -Page a of 47 .I I I I I !I I I I I I I I I I I .,:.!~) INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 4. Control Area 3 -All Building Areas Except Rooms 128/Control Area 1 and 140/Control Area 2 [continued] • Hazardous Materials [continued]: • Use Conditions & Operations [continued]: . n * Room 118-Bulk Solutions [Mixing/Blending Operations]: r'l, • Room 118 will be usec:l.,to mix/blend bulk solutions involving a combination of closed and open system use conditions. • Solutions will be made by mixing/blending raw materials in mixing/blending vessels, with individual batch sizes ranging from 22.5 liters [6 gallons] to 600 liters [159 gallons]. • There will be 17 different solutions made, with only 1-4 different solutions made at any time. Hazard classifications for the different' • solutions will be as follows, with the 3 solutions that will contain Class I, II or Ill-A Liquids indicated in bold print. * Gel Clear: Combustible Liquid Ill-A, Corrosive * Gel Drying: Flammable Liquid I-C, Irritant Other Health Hazard * IEF Anode Buffer: Corrosive * IEF Cathode Buffer {2 different solutions]: Irritant, Toxic * Native TriGly Running Buffer: Nonhazardous * NuPage Antioxidant: Corrosive * NuPage LDS Sample Buffer: Nonhazardous * NuPage MES SDS Running Buffer.· Nonhazardous * NuPage MOPS SDS Running Buffer: Nonhazardous * NuPage Transfer Buffer: Nonhazardous · * Simply Blue Safe Stain: Combustible Liquid 111-8, Irritant * Tricine SOS Running Buffer: Irritant * TrisGly SDS Running Buffer: Nonhazardous * TrisGly Transfer Buffer: Nonhazardous * Zymogram Developing Buffer: Nonhazardous * Zymogram Renaturing Buffer: Irritant • Raw materials will be transferred into mixing/blending vessels as follows, with the vessel open during the transfer operation: * Water will .be transferred into the vessel. * Liquids will then be manually added from </=4-liter [</=1.06-gallon] bottles. * Solids will then be manually added. • Once the raw materials have been added, the vessel will be closed and the solution will be mixed using an electric mixer. • After mixing, a peristaltic pump will pump the mixed solution through a closed tubing system into filling machine in Room 119 where the solution will be bottled. Pres~ure within the tubing will be </::;5 psig. • General/area exhaust ventilation at >/=1 cfrn per sf of floor area wil be provided in the room. See Attachment 2D for nonflammable vapor exhaust conditions. ,a,,* Room 119-Clean Room.[Filling/Bottling Operations]: r v • Room 119 will be will be an uncertified 100,000 particle clean room used for bottle filling of the solutions piped from Room 118. • There will be four [4] filing machines in the room, with one machine used only for the Gel Drying solution. • 0.5-liter [0.13-gallon] and 1-liter [0.26-gallon] bottles will be filled, with </=6 bottles filled at any time. • The maximum number of bottles that will be open [uncapped] within the enclosed machine wfll be 12 [6 liters (1.6 gallons] to 12 liters [3.2 gallons]. • Machine used for Gel Drying solution will be ventilated and exhausted, with exhaust to the exterior of the building. • General/area exhaust ventilation at >/=1 cfm per sf of floor area wil be provided in the room. See Attachment 20 for nonflammable vapor exhaust conditions. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions-5/11/01 [Rev. 11 -Page 9 of 47 'Ii Is 11 h .. ii f ,~ ,. :I' I ii I ;I I ;1 I I, .: .. , I " INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS Table 3.0 -lnvitrogen Operations 5. Shipping & Receiving/Room 125 - General Storage +Area-Entire Room: </=8,500 sf • Storage Conditions: General/ordinary storage conditions -no high- piled combustible storage conditions. 6. Plans & Tl Construction Documents 'f' Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 + Commodities: • Class I-IV and finished product bulk solutions, with one [1] of the solutions classified as a Flammable Liquid I-C and one [1] classified as a Combustible Liquids Ill-A. • No hazardous materials, except for the 2 finished product bulk solutions indicated above •. • No high hazard commodities, as described in Attachment 2. + Rack Storage: • Racks: * Single-row. * Steel construction. * Dimensions: • 4' deep x 8' long x </=1 O' high • 3' deep x 8' long x </=1 O' high * </=5,storage levels/tiers. • Class I-IV commodities -no hazardous materials. • Storage to <12' above the finished floor. • Cartoned & uncartoned products -no palletized storage. + Floor/Palletized Storage: • Palletized. • Cartoned. • Includes finished product bulk solutions, with largest individual container= 1-liter [0.26-gallon]. • Storage to <6' above the finished floor. + Supplemental Information: See Attachment 2 -supplemental UFCICFC information re commodity classification and storage methods/conditions/types. , +See Attachment 3 fQr overview. + Refer plans submitted separately by MJK Architecture & Planning for details. Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations · Code Requirements & Provisions -5/11/01 [Rev. 1] -Page 10 of 47 i., \ t :.\': ,., .• J,~ ti' 11 •\ \u\•' ~, ~ ,\ ,\\\.\\ ·I ,· \.\ ·;I .,. ' ' \ .~,; .. :I "·I . ., INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 4.0 EXHAUST VENTILATION -CLASS I, II & Ill-A LIQUIDS - CONTROL AREAS 1 & 3 . . Class I, II and Ill-A Liquids will be used in Control Area 1 and Control Area 3, with material, use and exhaust ventilation system conditions as indicated in Table 4.0. See Table 3.0 for additional information for the use conditions listed in Table 4.0. Table 4.0 -Class I, II & Ill-A Liquids Use Conditions -~~-Control Area 1 128 -Residual/ Flammable Liquids I-B Manual transfer froni </=20-General/area exhaust ventilation at Waste Chemical . liters [</=5.3-gallon] >/=1 cfm per sf of floor area. Stora·ge ri containers into storage vessels drums/containers . 109-T.C. Flammable Liquids I-B + Closed and open system Existing/previously approved/ Room [Existing] use conditions. permitted conditions -use/transfer . ~i + </=0.25 gallon in within exhausted enclosure or use/transfer at an time. exhausted fume hood. 118-Bulk + Combustible Liquids + Transfer of raw material General/area exhaust ventilation at Solution -Gel II & Ill-A liquids in ~n open system >/=1 cfm per sf of floor area. Clear, Gel Drying + Flammable Liquids condition, with transfer & NuPage I-B & I-C limited to </=4 liters Antioxidant [Additives for Gel [</=1.06 gallons] at any Solutions Clear, Gel Drying & time. ~ NuPage Antioxidant + Mixing operations and Solutions] transfer of finished product in closed s stem condition. 119-Clean + Combustible Liquids + Closed and open system General/area exhaust ventilation at Room Bottling/ Ill-A use conditions. >/=1 cfm per sf of floor area. Filling + Flammable Liquids +</=12 liters[</= 3.02 Operations -Gel I-C gallons] open at any time. Drying & Gel :\,.- Clear Solutio s 121-+ Combustible Liquigs + Closed and open ~ystem Use within exhausted enclosures, Manufacturing II & Ill-A use conditions. exhausted fume hoods .and walk-in fl,_ + Flammable Liquids +</=0.002 to </=1.06 gallons exhausted enclosures/hoods. I-B & I-C in use/transfer at an time. 154-DNA Flammable Liquids I-B + Closed system use Existing/previously approved/ Synthesis conditions. permitted conditions -use/transfer · [Existing] Gf) +</=5.03 gallons in within exhausted enclosure or use/transfer at any time. exhausted fume hood. l' Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1]-Page 11 of 47 '.I ll I I I I I 11 ,I \. . 1 \I L., ;I t. ii 'u /I \ }, ,\Is. ii ·1 ·'. INVITROGEN CORP.ORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS UBCICBC Section 1202.2.2 requires general/area mechanical exhaust ventilation in B, F & S Occupancy areas in locations where Class I, II or Ill-A Liquids are used, with the exhaust ventilation sufficient to produce six [6] air changes per hour, with exhaust taken from a point at or near the floor level [within 12" of the lowest point in the room]. lnvitrogen Corporation proposes to use local exhaust ventilation as an alternate method of compliance to general/area ex~aust ventilation in the .locations identified io Table 4.0 in bold print [109/T.C. Room [existing previously approved/permitted conditions], 121/Manufacturing, 154/DNA Synthesis [existing previously approved/permitted conditions] for which general/area mechanical exhaust ventilation i!> not indicated. As indicated in Table 4.0, local mechanical exhaust ventilation will be provided at locations where Class I, II or Ill-A 'Liquids are transferred in open system through one [1] or more of the following methods: • Use/transfer of CJass-I, II or Ill-A Liquids within exhausted laboratory fume hoods. • Use/transfer of Class I, II or Ill-A Liquids within exhausted enclosures. • Lise/transfer of Class I, II or Ill-A Liquids under exhausted hoods . • Use/transfer of Class I, II or Ill-A Liquids within exhausted walk-in hoods/enclosures. The use of local mechanical exhaust ventilation is an alternate method of compliance to the general/area exhaust ventilation of 6 air changes per hour addressed in UBC/CBC 1202.2.2. Local mechanical exhaust ventilation, designed and installed to capture vapors at their point of generation, will provide a more effective method for control of flammable and combustible liquid vapors than will general/area exhaust ventilation. This alternate method of compliance is hereby submitted and requested by lnvitrogen Corp~ration in_ accordance. with the provisions set forth in UBCJCBC 104.2.8. NOTE: See Attachment 2D for nonflammable vapor exhaust conditions for Class I Flammable Liquids. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue; i.a Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1 J -Page 12 of 47 I I ·I I I I I I :I :I I I 11 .1 I I 'I I :I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS . 5.0 CODE ANALYSIS The Code analysis that follows on pages 14-47 addresses applicable Uniform/California Building Code and Uniform/California Fire Code conditions and requirements for IC hazardous materials conditions and operations.3'4 Attachments to this report related to the code analysis are as fo!lows: ..... :~1:~1~1NJ,)tJ~ll1:t1~ ~I~ltt!ltl~~?:J:~~1;:fi_~iit1t:~~~V~i1.fili~tt:~~~i~~~~~i¾~~i~~~~l:It.lf;1ij~:.@J 1 Hazardous Materials Inventory Analysis .1A Control Area 1 -Room 128-S1 Occupancy 1 B Control Area 2 -Room 140 -S1 Occupancy 1 C Control Area 3 -Balance of Building -B/F.1/S 1 Occupancy 1 D Building Inventory -Control Areas 1-3. 1 E Definitions for Abbreviations 2 Supplemental Information 2A Storage Commodity Classifications. 28 Definitions for Terms -Specific to lnvitrogen Operations 2C OSHA Regulations -Battery Charging Operations 20 Nonflammable Vapor Exhaust Conditions -Class I Flammable Liquids 3 Site & Building Plans -Over.view A-1 Site Plan A-2 Demolition Plan A-3 '! s Floor Plan/Area of Tl Work A-4 2n Floor Plan/Area of Tl Work Conditions other than the conditions specifically addressed or described herein are outside the scope of this report. Discrepancies between the information presented herein and actual conditions and conditions presented on plans are the sole responsibility of lnvitrogen Corporation. Verification of compliance with the Code requirements and provision~ addressed herein is outside the scope of this report. 3Applicable Codes: The 1997. Uniforrn/1998 California Codes have been used as the baseline for requirements and conditions applicable to thi~ project. 4Existing Operations: The following operations/areas are existing, previously approved conditions to which no tenant improvement changes are planned. These operations/areas ·are not intended to be addressed in this report as existing conditions are presumed to comply. Hazardous materials information/conditions for these areas are provided for information/reference only .. • 103 -Facilities • 104, 105, 106, 157, 158-Offices • 109,112, 152-T.C. Rooms. • 11 O & 111 -Men's & Women's Rooms • 125 -Shipping & Receiving · • 128 -Chemical Storage Room • 130 -Boiler Room • 140 &-151 -Telephone Rooms • 151 -Electrical Room • 154 -DNA Synthesis • 155 -Micro Array •156-Lab . • 160 ~ Janitor Closet • 163-Shop • 165 -[Operations not identified on plans] • 2nd Floor, except new 342 sf 2nd floor area TEriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1] -Page 13 of 47 ............ i-----------------INVITR.OGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS + UBC/CBC 204 1. Occupancy & Control Area Conditions + Occupancy: I Same as IC conditions. + UBC/CBC 307 . + UBC/CBC Table 3-B • Major Use: B, F1, S1 • Minor Accessory Use: A3 + Control Areas: • Number: 3 • Locations & Occupancy Conditions: * Control Area 1: • Location: Room 128 • Operations: Residual/Waste Chemical Storage • Occupancy: S~ 1 • Hazardous Materials Inventory: Attachment 1A + Control Area 2: • Location: Room 140 • Operations: Raw Material Storage • Occupancy: S-1 • Hazardous Materials Inventory: Attachment 1 B * Control Area 3: -• Location: Building areas not included in Rooms 128 & 140 • Operations: Manufacturing,·shipping/receiving & general storage and support operations. •·Occupancy: B, F-1, S-1, with minor accessory A- 3 use area [lunch room] • .Hazardous Materials Inventory: Attachment 1 C +Plans: 'f Eriksen-Rattan Associates Inc. • See plans provided through MJK Architecture & Planning. • See Attachment 3 for overview. 4719 Palm Avenue, La Mesa CA 91941 + UBC/CBC Tables 3-D & E + UFC/CFC 204 + UFC/CFC 209 + UFC/CFC 7901.1 + UFC/CFC 7902.5 + UFC/CFC Table 7902.5-A + UFC/CFC 8001.1 + UFC/CFC 8001.8 + UFC/CFC 8001.15 + UFC/CFC Tables 8001.15-B & B Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1) -Page 14 of 47 _. .. aii .. ~--0-----1 T-l -W -:--r-·---·_ ------ INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 2. Occupancy & Control Area Separations • Occupancy Separations: See Control Area separations · • Control Area Separations: 1 -hour fire-resistive occupancy separation between Control Areas, as follows: • Control Area 1-Room 128: Separated from Control Area 3 Rooms 125 & 130. • Control Area 2 -Room 154: Separated from Control Area 1 Rooms 139 & 144. • Control Area 3: * Rooms 139 & 144: Separated from Control Area 2/Room 154. * Rooms 124 & 139: Separated from Control Area 1 Room 128. + Hazardous Materials Inventory: See Attachment 1. +Plans: • See plans provided through MJK Architecture & Planning. • See Attachment 3 for overview. TEriksen-Ratlan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 • Occupancy Separations: Same as IC conditions - none required. • Control Area Separations: Same as IC conditions, with 1-hour fire-resistive occupancy separations complying with the following conditions: • Vertical Separation -Walls: * 1-hour fire-resistive construction. * 1st floor, extending to 2nd floor. , * 2nd floor, extending to roof. • Horizontal Separation -Floor between 1st & 2nd Floors: ' * 1-hour fire-resistive construction. * Includes structural members supporting the, separation. · · • Openings: * Doors: • 60-minute labeled self or automatic closing assemblies. • Glazing limited to 100 square inches, with a minimum dimension of 4 inches. * Duct Penetrations: • Smoke Dampers: * At penetrations of occupancy/Control Area separation walls; or * Ducts located in 1-hour fire-resistive shaft; or * Alternate method of compliance acceptable to the Building Department. • Fire Dampers: * At duct penetrations of occupancy/Control Area separation walls and floors; or ' * Ducts located in 1-hour fire-resistive shaft; or * Alternate method compliance acceptable to the Building Department. · * Windows: 60-minute labeled assemblies. Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1}-Page 15 of 47 ·:---., ......... ...... c.alllllllll~'· ~ "~ ~ il~ ... -'lf'L .. ' ·-····· -er-, ' ,--... ·-·---" ' INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 3. Draft Curtains 4. Smoke & Heat Venting + Undivided Building Area >50,000 sf: Not applicable I + Same as IC conditions --not applicable. to IC conditions --no undivided building area >50,000 sf. + High-Piled Combustible Storage: Not applicable to IC conditions --no high-piled combustible stqrage. +H Occupancies >15,000 sf: Not applicable to IC Conditions --no H occupancy conditions in the building. + Undivided Building Area >50,000 sf: Not applicable I + Same as 1c; conditions -not applicable. to IC conditions -no undivided building area >50,000 sf. + High-Piled Combustible Storage: Not applicable to JC conditions -no high-piled combustible storage. + H Occupancies: Not applicable to IC conditions --no H occupancy conditicms in the building. -:····-· ..... - + UFC/CFC 8102.6 + UFC/CFC Table 81-A + UFC/CFC Std 81-2 + UBC/CBC 906 + UFC/CFC 8003 + UFC/CFC 8102.6 + UFC/CFC Table 81-A + UFC/CFC Std 81-1 + UBC/CBC 906 - T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions-5/1.1/01 [Rev. 1]-Page 16 of 47 .. }-~ .. ... .. .. ---.. ,, .. ... .. -. .. -INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 5. Separation of . · Incompatible Hazar~ous Materials& Conditions NOTE: Not specifically related to building construction conditions. +Incompatible Hazardous Materials: • Acids & Bases: Strong Acids [pH: <4] and strong Bases [pH: >10) will be separated from each other. • Class I, II & Ill-A Liquids will be separ~ted from: * Oxidizers * Water Reactives 2 • Oxidizers will be separated from: * Class I, II & Ill-A Liquids . * Flammable Solids • Unstable Reactive 3 materials will be separated from: * All other physical hazard materials. • Water Reactives 2 will be separated from: * All liquids. • Separation of incompatible materials from each other will be by one [1] or combination of the following conditions: * Storage in separate approved cabinets. * Storage in separate rooms. * Isolating incompatible materials storage by a noncombustible partition extending >/=18" above and to the sides of the storage. * Segregating incompatible materials storage by a distance of >/=20'. * Special Conditions -Water Reactives: Water Reactives 2, if located in the same room with Class I, II or Ill-A Liquids, will be stored in an approved storage cabinet. • Powered lhdustrial Trucks/Forklifts: Powered industrial trucks/forklifts, if used within the building, will be located as follows': • Battery Powered: >/=5' from combustible materials. • LPG Powered: >/=20' from combustible materials. +Incompatible Hazardous Materials: Same as IC conditions. · • Powered lndu_strial Trucks/Forklifts: Same as IC conditions. -.. .. • UFC/CFC 103.1.2 • UFC/CFC 210 • UFC/CFC 1108 • UFC/CFC 7902.5.4 • UFC/CFC 8001.11.8 •OSHA: • CFR 1910.178 • CFR 1926.403 - Y Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1] -Page 17 of 47 ~-... i--------.. , •. --... .. --;-· .-.. ... --... INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA . . UNIFORM/CALIFORNIA CODES ANALYSIS 6. General Area • Types: Mechanical ventilation or combination of Ventilation System mechanical & natural ventilation. • Mechanical Ventilation: • Capable of supplying >/=15 cfm of outside air per occupant in all portions of the building during the time the building is occupied. • Registers located >8' above the floor where the air velocity is >10 fps. • Natural Ventilation: • Openable exterior openings -area >/=1/20 of total floor area. • Exterior openings will open directly onto a yard. • Plans: See architectural & mechanical plans provided through MJK Architecture & Plannii:ig. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Same as IC conditions. + UBC/CBC 1202.2.1 Technical Reportrrenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1)-Page 18 of 47 ~ Llllill .a ._ .,."ii \f.ilfl ''if& (:i"'II tlr··i ~Ill ,-,---, flfit <firll !.fe'I f'f~"I. :ifMJ "fli ~-.·-·-·a .. i·--··t INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 7. Exhaust Ventilation System & Explosion Control -Class I, II & Ill-A Liquid$ [continued on next page] + Use & Transfer Conditions: See Table 3.0, Items. 3- 4 and Table 4.0. + Exhaust Ventilation System Conditions: • General: See Tabl_e 3.0, Items 2-4 and Section 4.0. • General/Area Exhaust Ventilation: * Tl Locations: ~ / • Control Area 1 ..,_ Room 128 f ""-• Control Area 3 -Rooms 118 & 119 · * Conditions: ~ • Control Area 1 -Room 128: >/=1 cfm per sf of floor area and >/=6 air changes per hour. • Control Area 3 --Room 118: >/=1 cfm per sf of floor area and >/=6 air changes per hour. • Control Area 3-Room 119: * Clean room supply and exhaust air conditions. * >/=15 air changes per hour [>2 cfm per sf of floor area]. - • Local Exhaust Ventilation Systems -Alternate Method of Compliance: * Tl Locations: • Control Area 3 -Existing Previously "f'L .. Approvjd/Permitted Conditions: Rooms 109 & 154 c.,f) v.\. • Control Afea 3-New Conditions: Room 121 * Proposed Exhaust Ventilation System Conditions -New/Tl Locations: • Local exhaust ventilation to capture and exhaust Flammable Liquids I and Combustible Liquids II & Ill-A vapors at their points of generation, as described in Tables 3.0 & 4.0, is proposed to be used. • See Section 4.0 for request to allow use of local exhaust ventilation as an alternate method of compliance in new Room 121 ... t(}"'\., • Application & Alternate Method of Compliance: • Either general/area exhaust ventilation or local exhaust ventilation required in rooms/areas were Class I Flammable, Class II Combustible or Class 111- A Combustible Liquids are used in a "use-open" condition, unless it can be demonstrat~d that there will be no flammable vapor-air concentrations. • Use of local exhaust ventilation is considered to be an alternate to general/area exhaust ventilation and requires specific acceptance/approval of the Building Official. + Local Exhaust Ventilation: Same as IC conditions, provided the Building Official accepts local exhaust ventilation. + General/Area Exhaust Ventilation: The following requirements will apply if local exhaust ventilation is not accepted by the Building Official: • Mechanical system. • 6 air changes per hour. • Exhaust taken from a pint at or near [within 12"] of the lowest point of the room/area. • System designed and installed as Class 1 Product Conveying Exhaust Duct System --see Item 8. l' Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1]-Page 19 of 47 + UBC/CBC 104.2.8 + UBC/CBC 1202.2.2 + UFC/CFC 207 + UFC/CFC 7902.1.5 + UMC502 +UMC506 .. ..... .. .. .. --.,,.,., -· ~ --1··· ---,,-·----•. ~ .. -.--r, , .. < .. INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA - UNIFORM/CALIFORNIA CODES ANALYSIS 7. Exhaust Ventilation System & Explosion Control - Class I, II & Ill-A Liquids [continued] 8. Class 1 Product Conveying Exhaust Duct Systems - Class I, II & Ill-A Liquids [continued on next page) + Explosion Control: Not applicable to 1.C Conditions: • No use of Class I liquids in amounts >Exempt Amounts. • No explosive vapor-air mixtures under normal operating conditions. . • Use conditions will be provided with local mechanical exhaust ventilation. + Nonflammable Vapor Exhaust Conditions -Class I Flammable Liquids: • See Attachment 2D for both new and existing operations. • Nonflammable vapor-air mixtures and exhaust conditions can be maintained, if the exhaust ventilation rates/conditions indicated in Attachment 2D are provided. + Plans: See mechanical & architectural plans provided through MJK Architecture & Planning. + IC Locathms & Conditions: • See Table 3.0/ltems 2-4 and Section 4.0. • See Item 7. +General: ·• Systems will be designed & installed to control, capture &· remove emissions generated. • Emissions will be confined to the area in which they are generated by air currents, hoods or enclosures and exhausted through a duct system to a safe location or treated by removing contaminants. • Exhaust through ducts will be nonflammab_le. • Exhaust ducts will not to extend into/through ducts & plenums. + Incompatible Vapors: Not applicable to IC conditions -no incompatible Class I, U or 111-P, Liquid vapors. + Explosion·control: Same as IC condition~ -not ~pplicable. + Nonflammable Vapor Exhaust Conditions -Class I Flammable Liquids: Same as Tl conditions -exhaust ventilation conditions addressed in Attachment 2D, If provided, will allow exhaust be addressed as nonflammable. +Class 1 Product Conveying Exhaust Duct System: • Ducts conveying nonabrasives, such as smoke, spray, mists, fogs, noncorrosive fumes & gases, light fine dusts or powders. • Includes hoods/enclosures connected to the system. + Hoods/Enclosures: • Sheet metal/steel -->/=0.033 inch [20 gage] base metal thickness, or other approved materials. • Approved nonmetallic hoods/enclosures can be used for nonflammable materials. + Recirculation of Exhaust Air: No recirculation of contaminated air to occupied areas. + UBC/CBC 104.2.8 + UBC/CBC 1202.2.2 + UFC/CFC 207 + UFC/CFC 7902.1.5 +UMC502 +UMC506 + UBC/CBC 713.10 + UBC/CBC 713.11 + UBC/CBC 1202.2.3 + UMC/CMC 402.4 + UMC/CI\/IC 502 + UMC/CMC 505 + UMC/CMC 506 + UMC/CMC 609 + UFC/CFC 7902.5.11.4 + UFC/CFC 7903.2.3.5.3 + NFPA 91/2-1 thru 2-6 - T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1) -Page 20 of 47 ._ lllil ~ ~ Itri; Vil'(g ::'j(:i; ~li-,:,.ii. ?'ff"lt ,;,,,--. "'.k'~I! ffffl; ?(fl INVITROGE~ CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS .. ;' . .,.,,~, -'I1r1 .. :r··u 8. Class 1 Product Conveying Exhaust Duct Systems - Class I, II & Ill-A Liquids [continued) [continued on next page] T Eriksen-Rattan Associates Inc. + Fire Protection in Exhaust Ducts: • Class I Flammable Liquid Use Locations & Exhaust Conditions: * Control Area 1: fL • Room 128 -general/area exhaust ventilation. * Control Area 3: th\..• Rooms 118 & 119-gen~l/area exhaust r .-.llr.eAUI. at·iafr.-. .....-lf J fL • Rooms 09*, 121 154* -local exhaust ventilation ro gh exhausted hoods and exhausted enclosures. [*Existing previously approved/permitted operations/conditions.] * Conditions Required to Maintain Nonflammable Vapor-Air Concentrations: • Nonflammable vapor exhaust [flammable vapors </=10% of LFL] through exhaust ducts can be achieved .if exhaust ventilation conditions indicated in Attachment 2D· are provided. • Also, see Table 3.0/ltems 3-4, Section 4.0 and Attachment 2D. · NOTE: Refer to Mechanical Plans -specific exhaust ventilation conditions were not available at the time this report was prepared. • Other Locations/Conditions: * No use of Class I Flammable Liquids ·based on materials, amounts and use conditions identified in Table 3.0/ltems 2-4 & Section 4.0. * No flammable particulate accumulation in exhaust ducts based on materials, amounts and use conditions identified in Table 3.0/ltems 2-4 & Section 4.0. + Elevated Temperatures: Not applicable to IC conditions -no elevated temperature exhaust air. + Explosion Venting: Not applicable to IC conditions - no explosive vapor/air concentrations in exhaust ducts. + Plans: See mechanical plans & construction documents provided through MJK Architecture & Planning. + Minimum Velocities & Circulation: • Contaminated captured by an air stream at the area where emissions are generated and conveyed into a product-conveying duct system. • Vapors from Flammable Liquids diluted to </=25% of their LEULFL with air that does not contain other contaminants. • Vapors generated from Flammable Liquids to be diluted </=10% of their LEULFL for application of nonflammable vapor exhaust conditions. + Makeup Air: • Makeup air provided to replenish air exhausted by the exhaust system. · • Makeup air electrically interlocked with exhaust systems. • Makeup air intakes located so as to avoid recirculation of contaminated air within enclosures. + Exhaust Ducts: • Through Building: * Extend directly to the exterior of the building without entering other spaces. * Cannot extend into through ducts/plenums not associated with the Class 1 exhaust duct system. • Construction: * Sheet metal/steel or other materials approved/listed for use with Flammable & Combustible Liquids. * Flexible metallic duct may be used for connecting ductwork to equipment. * Approved nonmetallic hoodsiducts allowed to be used for nonflammable corrosive vapors. * Metal hoods/ducts used for exhaust of corrosives to be protected with corrosion-resistant material. • Thickness: Depends on pressure, type & size of duct -refer to UMC/CMC Tables 5-B & 6-A. • Fittings: * >/=2 gages thicker than thickness required for straight runs. * Branches to connect to main duct(s) at the large end of transitions at >45o angle. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions-5/11/01 [Rev. 1]-Page 21 of 47 + UBC/CBC 713.10 + UBC/CBC 713.11 + UBC/CBC 1202.2.3 + UMC/CMC 402.4 + UMC/CMC 502 + UMC/CMC 505 + UMC/CMC 506 + UMC/CMC 609 + UFC/CFC 7902.5.11.4 + UFC/CFC 7903.2.3.5.3 + NFPA 91/2-1 thru 2-6 ,,.flk ,_.. [9111 ,--··:c-:_.... ~ r.-.-.. ~ .. f~ :::-.. -, __ ~ [-.;,~ ~ ti-·-· .,. .... ,_ : .... ::..... rr-·1 'Ill .. .. .. INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 8. Class 1 Product I [See previous page.] Conveying Exhaust Duct Systems - Class I, II & _Ill-A Liquids [continued] [continued on next page) 'Y Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 + Exhaust Ducts -continued: • Cleanouts -Corrosive Vapors & Vapors with Particulate: Accessible cleanouts at 1 0' intervals and at changes in direction. • Fire Protection: * Locations: See IC locations/conditions. * Sprinklers or other fire-protection devices to be installed in duds having a cross-sectional dimension >10" when the duct conveys flammable vapors or flammable gases. [Flammable vapors are the concentration of flammable constituents >/=10% of the lower flammability limit (LFL).] * Sprinklers, when provided, to be installed as follows: • Horizontal Ducts: 12' intervals and at changes in direction. • Vertical Runs: Top and at alternate floor levels. * See Item 21 for fire sprinkler design conditions. • Access Openings for Sprinklers: Access openings provided for access to sprinklers located in ducts. • Access Openings for Equipment: Access openings provided for equipment located in ducts that requires servicing. • Supports: * </=8" Ducts: </=12' intervals. * >8" Ducts: </=20' intervals. * Design: Assume 50% of duct is full of the vapors being conveyed. • Protection from Physical Damage: Protected by guards when installed in locations where they may be subiec!_phy~lcal damage. · + UBC/CBC 713.10 + UBC/CBC 713.11 + UBC/CBC 1202.2.3 + UMC/CMC 402.4 + UMC/CMC 502 + UMC/CMC 505 + UMC/CMC 506 + UMC/CMC 609 + UFC/CFC 7902.5.11.4 + UFO/CFC 7903.2.3.5.3 + NFPA 91/2-1 thru 2-6 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions-5/11/01 [Rev. 1]-Page 22 of 47 :.JIii .. ... .. .. -.. .. -···: ;._ ' t-·-· C -INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS -----.. .. f .. .. - tir' :,";i··,t,r""..:i"·'.·-t>'··,»,~·t· .,.ii;;?.'' ·,·r:-cJ! f"fC'0f~··{·~""-"'''~'~'""""'.v~~"'"""i~..r:.cs.i~--""K;'i;'~:ll.rt£~·~ :"&!'(> ~·--;, 11.ft,:;·H'A'-ib'l''.;;jW•.'t:t"'iP''"'"'"'"m-;.t.;iil,.,W,(A'J.!l·i~-.r"'';;'">'~.)~~·'ti-P~~·· .c·,;~.if•f-i:09'"ifj;iif\08V~1';;.;..;,f*@~3:'i ?.,;-;;;t;;:~.Q.y~:~..QP~!.!9!J.:'.:v~~r ~~in;•.!l.Jm!.qg9.llJ1!..@!t!!-!IM-'~,.,,..:i~,,,JJ~mg,~1!.i:?i!,&~~Vr.it; },if,1tEZ~~::.~(~9~A:U~--M!',Jr&u~~,~;,~¼,iJl...,~,dtt~!t~1!tJ,_Yi:;?feylftt~ 1.w..Ji~--P",!1i',j'-i?~r~R¥~-~~J:~ · · · · + Exhaust Ducts -continued: 8. Class 1 Product [See previous page.] • Exhaust Outlet Termination: Conveying Exhaust * Nonflammable Vapor Exhaust: Duct Systems -• >/=1 0' from the following conditions: Cla~s I II & Ill-A * Prop~rty li~es . . . . . . L"qu·d~ * Openings mtc;, burldmg which are m direction of I I exhaust discharge. . * Above grade. [continued] I I • >/=3' from exterior walls & roofs. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 * Flammable Vapor Exhaust: • >/=~o· from the following conditions: * Property lines. . * Combustible walls or openings into building located in the direction of exhaust discharge. • >/=10' above adjoining grade. • >/=6' from exterior walls or roofs. • Clearance from Combustible Construction: >/=18" or protected with approved construction [i.e.: insulation]. • Elevated Temperatures: Same as IC conditions -- not applicable. • Explosion Venting: Same as Same as IC conditions --not applicable. • Dampers: * Fire/Smoke Dampers: Not allowed, except for the following conditions: • Through fire walls/floors. • Collection system at. end of system protected by fire sprinkler system. • Duct system protected by fire sprinkler system. • NOTE: Supply air to be interlocked with exhaust air to insure adequate supply/make-up air for exhaust system to operate properly. * Volume/Balancing Dampers: · • Allowed only for weather or back-draft protection, located only on clean-air side of-filtration system. • Balancing devices secured to prevent inadvertent adjustment or loss of transport velocity. Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1) -Page 23 of 47 ( ... ftllil ; .. .. .,,--£. i .. ••• ' ... .. .. -,·-----. .. ... n-~ • .. .. INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 9. Class 5 Product Conveying Exhaust Duct Systems -· Corrosives - Exhausted Hoods/ Exhausted Enclosures 10. Exhausted Hoods/ Enclosures NOTE: Owner furnished/ installed equipment not specifically related to building construction conditions. + IC Conditions: Corrosive liquids may be used within exhausted hoods/enclosures in the following Control Area 3 locations where local exhaust ventilation systems are provided: • Room 121 -Manufacturing f 'v • Room 137 -Fermentation ,f \ · • Room 154 -DNA Synthesis [Existing previous€£) approved/permitted operations/conditions.] NOTE: Exhaust ventilation for liquids other than Class I, II & Ill-A is not specifically required because materials will be used in amounts <Exempt Amounts. Refer to plans/equipment documents provided separately by others. * Maintain negative pressure in enclosure/under hood with respect to room, with air currents created by exhaust system to c~pture contaminants and transport them directly to/through an exhaust duct system -see Item 8. * >/=100 fpm average ventilation velocity at face/front · opening. . * >/=70 fpm minimum ventilation velocity at any point of face/front opening. • Electrical: See Item 11 for electrically classified locations. + Exhausted Enclosures: • Construction: * Compatible with· materials located therein. * Noncombustible when used for the following conditions: • Increase in exempt am.aunts. • Storage/use of Toxic or Highly Toxic gases. • Ventilation: Same as exhausted hoods hoods. • Electrical: See Item 11 for electrically classified locations. .. ;···1• - + UBC/CBC 713.10 + UBC/CBC 713.11 + UBC/CBC 1202.2.3 + UMC/CMC 402.4 + UMC/CMC 502 + UMC/CMC 505 + UMC/CMC 506 + UMC/CMC 609 + UFC/CFC 7902.5.11.4 + UFC/CFC 7903.2.3.5.3 + NFPA 91/2-1 thru 2-6 + UFC/CFC 206 + UFC/CFC 8001.10.4 • UMC/CMC 505.7 - TEriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions-5/11/01 [Rev. 1)-Page 24 of 47 [~ .. ~ \• .... ~ .. .. ,,_ ~ !,--~ all MU$ ~ ~ ... -.. t-., ~ ~ i ...... ~ .. -' INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA-CODES ANALYSIS 11. Electrically Classified Areas - Class I Flammable Liquids in Use.& Transfer + Class I Flammable Liquid Use or Transfer Operations: • Locations: * Cc;>ntrol Area 1: Storage Room. * Control Area 3: ,pt.· 128 -Residual/Waste Chemical . • New/Tl Operations: _ pt, * 118 -Bulk Solution (Gel Drying Solution] f~ * 119 -Clean Room [Gel Drying Solution Bottling] pi\, * 121 -Manufacturing (Various-Locations] • Existing Previously Approved/Permitted Operations: }?'\.. * 109 -T.C. Room ( f;) * 154 -DNA Synthesis NOTE: , Pt..• Control Area 1 -Room 128 will-have electrically _ classified areas, but may not necessarily have electrical wiring/equipment/devices within such areas. • Control Area 3: l'1, * Room 118 will have co,:iditions where flammable vapor/air mixtures could exist under normal operating conditions during fill operations before the mixing vessel is closed · for the Gel Drying solution. f"L * Room 119 bottling machine for Gel Drying solution will be a piece of equipment in which flammable vapor/air mixtures could exist under normal operations. • Conditions: '* Mechanical exhaust ventilation -all locations. * See Table 3.0/ltems 2-4 and ~ection 4.0 for use, transfer and exhaust ventilation conditions. +Plans: • See electrical plans & construction documents provided through MJK Architecture & Planning. • No pits or recessed floor areas. + Application: • "Classified electrical" equipment, wiring & devices are required in the locations described below and on the following page, if such equipment, wiring & devices are located within the boundaries of the areas indicated. • If the conditions described on the·following page do not exist, "classified electrical" is not required to be provided + Class 1, Division 1-Group D Electrical Locations: • Open Ends of Vents: Within 3' of open end(s) of vent(s), extending in all directions. • Vents & FIii Openings: Within 3' of vent(s) and fill openings(s), extending in-all directions. • Equipment Where Flammable Vapor/Air Mixtures Could Exist Under Normal Operations: Area within 5' of any edge of such equipment, extending in all directions. • Class 1, Division 2-Group D Electrical Locations: • Open Ends of Vents: Area between 3' & 5' of open end(s) ofvent(s), extending in all directions. • .Vents & Fill Openings: Area between 3' & 5' from vent(s) & fill opening(s), extending in all directions. Also, up to 18" above floor within a horizontal radius of 1 O' from such openings. • Pumps, Bleeders, Withdrawal Fittings, Meters, Etc.: Within 5' of any edg_e of pumps, bleeders, withdrawal fittings, meters, etc., extending in all directions. Also, up 3' above floor level & within 25' horizontally from any edge of such devices. • Equipment Where Flammable Vapor/Air Mixtures Could Exist Under Normal Operations: * Area between 5' & 8' of any edge of such equipment, extending in all directions. * Also, area up to 3' above floor within 5'-25' horizontally from any edge of such equipment. • Areas Outside of Openings in Electrically Classified Area within 50' Horizontally of Flammable Vapor Source: Area within 10' horizontally of opening(s), up to 3' above the floor for a 5' radius. + UFC/CFC 7901.4 + UFC/CFC 7901.10 + UFC/CFC Table 7901.4-A + UFC/CFC 7903.2.2 + UFC/CFC 8001.9 + NEC 500-3 +NFPA • 30 • 325 • 491 • 497A • 497B .. V Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Reportffenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 (Rev. 1] -Page 25 of 47 ,._ .... '~ ; __ ~ ~ ... ~ f-t,......, [ .. ,i,---~ ... :.----------r: ~ I !,----~ §[--~ -er-. ~ &aliiiili;;-... '. .. --~-I~/~ ., ,_ E:: INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CO_DES ANALYSIS 12. Egress System 13. Liquid Transfer Operations - Hazard Ranking 3 & 4 Liquids -Control Areas 1 & 3 · (continued on next page] NOTE: Not specifically related to building construction conditions. Piping systems will be submitted for separate plan check/permit. • See plans provided through MJK Architecture & Planning. • See Attachment 4 -identification of applicable Code requirements and conditions is outside the scope of this report. + Control Area 3: • General: * Individual Container Sizes: • Hazard Ranking 3 Liquids: </=5.3 gallons [</=20 liters]. • Hazard Ranking 4 Liquids: <1.06 gallons [<4 liters]. * Maximum Transfer Amounts: • Class I Liquids: </=1.06 gallons [<4 liters]. • Class II & Ill-A Liquids: </=5.3 gallons [</=20 liters] * Liquid Transfer Me,hods: • Manual transfer. • Transfer operations will occur with local exhaust ventilation, as described in Items 7. & 8, Table 3.0/ltems 2-4 and Section 4.0. • Room 118/Bulk'Solution & Room 119/Clean Room [Bottling] -Gel Dry Solution: * Room 118: • Manual transfer of </=10 liters [2.6 gallons] at any time, with local exhaust or general area exhaust ventilation, as described in Items 7. & 8, Table 3.0/ltem 4 and Section 4.0. • Low pressure [<5 psig] peristaltic pump transfer ·through closed piping/tubing system to bottling machine in Room 119. ~'b-Room-119: • Ventilated, exhausted machine filling operation, as described in Items 7. & 8, Table 3.0/ltem 4 and Section 4.0. • 0.5-liter [0.13-gallon] and 1-liter [0.26-gallon] bottles filled, with </=6 bottles filled at any time. • Low pressur(:}J<5 J)Sig] filling operation. [Identification of applicable Code requirements and conditions is outside the scope of this report.] + Class I, II & Ill-A Liquids: • Positive Displacement Pumps: * Provided with pressure relief discharging back to the vessel, pump suction or other approved location; or * Interlocks provided to prevent overpressure. • Pressurized Systems: * Gases Used for Pressurization: Inert gases only - no air or oxygen. * Controls: Pressure-relief devices to limit pressure to </=maximum working pressure of vessels and piping systems. • Class I, II & Ill-A Liquids: Transfer by any of the following methods: * </=20-liter [</=5.3-gallon] containers. * Safety cans. * Approved closed piping system. * Vessels by an approved pump taking suction through an opening in the top of the vessel. • Gravity Tran~fer -Class 18, IC & Ill-A Liquids - Vessels >20-Liter [>5.3-Gallon]: Gravity transfer ,OK under the following conditions: * Approved self or automatic closing valve. * Spill control & containment provided [as required for H Occupancy conditions-see Item 17]. • Class I Liquids -Prevention of Static Accumulations: Bonding/grounding provided for Class I Flammable Liquid transfer systems/conditions to prevent static accumulations where differences of potential could be created. + UBC/CBC 302.3 + UBC/CBC 713.7 + UBC/CBC 1003 + UBC/CBC 1004 + UBC/CBC 1005 + UBC/CBC 1007 + UBC/CBC Table 10-A + UFC/CFC 7903.1.3 + UFC/CFC 8004.1.15 - T Eriksen-Rattan Associates Inc. Technical Reportrrenant Improvements -Hazardous Materials & Storage Operations 4719 Palm Avenue, La Mesa CA 91941 · Code Requirements & Provisions-5/11/01 [Rev. 1)-Page 26 of 47 ~. ~ .. £11111 ....... -L~ ~---~ ~ ~--~,-··111! .,._. ~ ~ ~- : __ _ ' f ~ ~ ~ ~ ~~,. ....• cr·-·11.., v,--...• ~, ----I .. T ···1 INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 13. Liquid Transfer Operations - Hazard Ranking 3 & 4 Liquids -Control Areas 1 & 3 [continued] NOTE: Not specifically related to building construction conditions. Pipingftubing systems will be submitted for separate plan checkfpermit. 14. Piping; Valves & Fittings.:. Hazardous ,,.. Materials & Compressed Gases [continued on next page) NOTE: Not specifically related to building construction conditions. Piping/tubing systems will be submitted for separate plan checkfpermit. + IC Conditions: • 118/Bulk Solution & 119/Clean Room: ' ~1-Transfer of solutions by peristaltic pump through closed piping/ tubing system from Room 118 to 119. * Solutions -Material Hazard Classes: • Combustible Liquid Ill-A • Combustible Liquid 111-B • Corrosive · • Flammable Liquid 1-C • Irritant • Nonhazardous • Other Health Hazard • Toxic • 121/Manufacturing: Inert/nonhazardous ~compressed gases -transfer through closed piping/tubing systems from cylinders to use locations. • Plans: Not intended to be part of this plan check/permit package -plans will be su~mitted . separately by others for separate plan check/permit. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 • Hazard Ranking 3 & 4 Liquids: • Class I, II & Ill-A Liquids: See above requirements. • Hazard Ranking 4 -Containers </=4 Liters [</=1.1 Gallon]: No specific requirements. • Hazard Ranking 3 -Containers </=20 Liters [</=5.3 Gallons]: No specific requirements. • Non-Gravity Transfer: Same as indicated for Class I, II & Ill-A Liquids. • Gravity Transfer: Same as indicated for Class I, II & Ill-A Liquids, except not allowed for Highly Toxic liquids. +Inert Compressed Gases: See ltein 19. +Design: Designed andfabricated from Materials compatible with material to be contained. + Strength: Adequate strength and durability to withstand pressure, structural & seismic stress, and · exposure to which subjected. +Standard·: General compliance with ANSI B31.3 • Low Melting Point Materials -Class I Flammable, Class Ill-A Combustible Liquids: If used, low melting point materials [i.e.: aluminum, copper:, brass, nonmetallic Materials, nonductile Materials] to comply with the following conditions: • Suitably protected against fire exposure. • located such that leakage resulting from failure will not present an exposure hazard. • located such that leakage can be controlled by operation of accessible remotely located valve(s). · + Locatio·n Limitations -Corrosive or Toxic Liquids: Cannot be installed in the following indoor locations: • Within any portion of an exit corridor. • Within any portion of a means of egress required to be enclosed in fire-resistive construction. • In concealed spaces in or above areas not classified as . H Occue_ancies. + UFC/CFC 7903.1.3 + UFC/CFC 8004.1.15 + UFC/CFC 7901.11 + UFC/CFC 8001.4.3 +ANSI A13.1 +ANSI B31.3 Technical Reportffenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1) -Page 27 of 47 ( .... .. ~ ,:.-· f:.. ... .. a::ai.a ~ .. ... --~ ; .. . ... .. ''°-illiiiila ---f~ ~~ ... ... .. .. INVITROGEN CORPORATION: 1600 Faraday Avenue, ~.arlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 14. Piping, Valves & Fittings - Hazardous Materials & Compressed Gases [continued] [continued on next page] NOTE: Not specifically related to building construction conditions. Piping/tubing systems will be submltt~d for separate plan check/permit. [See previous page.] T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 • General: * Piping system(s) to contain a sufficient number of manual control valves & check valves to operate system properly and to protect the area under both normal & emergency conditions. * Piping in connection with pumps to contain sufficient number of valves to control liquid flow in normal operation and in the event of physical damage or fire exposure. • Emergency Shutoff Valves: * Required for Corrosive, Highly Toxic & Toxic liquid supply piping/tubing in the follov,,ing locations: • At the point of use; and • At the tank or bulk source. * Identified and location visible and indicated by a sign. • Backflow Prevention/Check Valves: Provided when backflow could create a· hazardous condition or cause unauthorized discharge. • Drainage Control Valves: Manual drainage-control valves to be located remote from containment area/drainage system such that they can be operated in a fire condition. + Pipe Joints: • Liquid-tight. • Welded, flanged or threaded --welded required only when located in concealed spaces inside the building. • Nonmetallic joints to be approved. • Pipe joints dependent on friction characteristics or resilience of combustible Materials for mechanical continuity or liquid tightness of piping allowed only outside of building. + Pipe Bends: </=90o or at a radius less than 5 diameters of the nominal trade size of the pipe/tube [radius mE:?f!flUred from insidE:? edge of pipe/tube]. + UFC/CFC 7901.11 · + UFC/CFC 8001.4.3 +ANSIA13.1 +ANSI B31.3 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1) -Page 28 of 47 JIii, tall .. ~ ... !;'-~ 'it ... -~ ~ "-~ t-~ ~ ~ )' ..... crrl ~--Plil i'ft ... , .• q-·>--'ll ,., ·-··· ... .. tililil INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 14. Piping, Valves & · I (See previous page.] Fittings - Hazardous Materials & Compressed Gases [continued] NOTE: Not specifically ,:elated to building construction conditions. Piping/tubing systems will be submitted for separate plan check/permit. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 t' + Testing: One [1] of the following, prior piping system being enclosed or placed in use --no leakage or permanent distortion for >/=10 minutes: • Hydrostatically tested to >/=150% of maximum anticipated system pressure. • Pneumatically tested to >/=110% of maximum anticipated system. pressure, but not less than 5 psig at highest point of the system. + Identification -Piping/Tubing: Piping/tubing identified to indicate material conveyed with directional arrows--per ANSI A13.1 -as follows: • Each valve. • Each wall, floor, ceiling penetration. • Each change in direction. . • Every 20' or fraction thereof throughout piping runs. + Supports: Adequately supported & seismically braced, with bracing/support in accordance with the following_: · 3/4"=1" </=8' >/=1-1/4" -Horizontal </=10' >/=1-1/4" -Vertical Every Floor Level + UFC/CFC 7901.11 + UFC/CFC 8001.4.3 +ANSI A13.1 +ANSI 831.3 Technical ReporVTenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1]-Page 29 of 47 JIii , __ _ c.: ~--..... ,,. , f; ,_ .. i-.. ~ .. -~----..... .. ,_.... ~ --: f .. , ______ _ ,. t."_ INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 15. Limit Controls - Hazardous Materials NOTE: Not specifically related to building construction conditions. 16. Spill Control, Drainage& Containment - Hazardous Materials + Pressure Controls: Not applicable to IC conditions --I Same as IC conditions -not applicable. no stationary tanks or equipment containing materials which can generate pressures exceeding the tank or equipment design limits due to exposure fires or internal reaction. + Temperature Control: Not applicable to IC conditions --no hazardous materials conditions or processes involving hazardous materials requiring temperature control. + Liquid Level Limit Controls: Not applicable to IC conditions:· • Liquids manually added to open vessels in Room 118 -</=10 liters [</=2.6 gallons] at a time. • No open vessels in which hazardous materials are heated. • No tanks [mixing vessels only]. + Process & Piping System Controls: As described in Items 13-14. + Plans': Not intended to be part of this plan · check/permit package -plans will be submitted separately by others for separate plan check/permit. Not applicable to IC conditions --i.e.: I Same as IC conditions -not applicable. • No use/storage >Exempt Amounts. + No gravity transfer of Class I & II Liquids from containers having a capacity >5.3 gallons [20 liters]. &liiiiiliiL -.,,....,-~----· ~· ... .. ... .. • UFC/CFC Table 7902.5-A + UFC/CFC Table 7903.2-B + UFC/CFC Tables 8001.15-1 & B • UFC/CFC 8003.1.9 • UFC/CFC 8004.1.5 • UBC/CBC 307.2 • UFC/CFC 7901.8 + UFC/CFC Table 7902.5-A + UFC/CFC Table 7903.2-B + UFC/CFC 7903.1.3.5 • UFC/CFC Tables 8001.15-B & B 'f'Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1)-Page 30 of 47 ~.! tlJIII ,.-...:..~ ,;-· ~:;..~ , .... t~ r_.'§..._ ·t-~ i~ ;:~ :.I. I .. , ..... "~ ~ -..... -~--~ -~ .. INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNiA CODES ANALYSIS 17. Lighting 18. Ignition Source Control · NOTE: Owner furnished/ installed-equipment & conditions -not specifically related to building construction conditions. +Plans: • See electrical plans provided through MJK Architecture & Planning. • Adequate lighting by natural and/or artificial means will be provided. · • Artificial lighting will be in .accordance with the IES Lighting Handbook and applicable energy standards. • Means of Egress Illumination: Outside the scope of this report. • Exit Sign Illumination: Outside the scope of this reeort. • General: Same as IC conditions. • Means of Egress Illumination: Outside the scope of this report. • Exit Sign Illumination: Outside the scope of this· report. • General: Control of ignition sources, including I Same as IC conditions. electrical equipment, wiring and devices, will be in accordance with applicable Code conditions and requirements. · +Open Flames & High Temperature Devices: None-- not applicaple to IC conditions. + Electrically Classified Areas/Conditions: See Item 11. + Prevention of Static Electricity -Class I Flammable Liquids: Precautions will be taken to prevent the accumulation of static electricity. See Items 11 & 13. + No Smoking & Signage: "No Smoking" signs will be posted as required by the Fire Department. [State law prohibits smoking inside the building, essentially making signage both redundant & unnecessary.] .. t-'<:,-~ t UBC/CBC 1003.2.8 t UBC/CBC 1003.2.9 t UFC/CFC 8004.1.9 t UFC/CFC 7901.4 t UFC/CFC 7901.10 t UFC/CFC 8001.9 .. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements·-Hazardous Materials & Storage Operations Code Requirements & Provisions~ 5/11/01 [Rev. 1] -Page 31 of 47 .. ..... ?JIii.:" r: ' ,:. ' --• I ... t---~ ,. .... ~ .. ·~-\ .. ...... }lit -, lilaiiliiat ~ :;---· ;j .. ~ .... i.-.. ,,_ L ,_ 2 -.. ft .. INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 19. Compressed Gases [Inert/ Nonhazardous] [continued on next page] ' NOTE: Owner furnished/installed equipment -not specifically related to building construction conditions Piping/tubing systems will be submitted for separate plan check/permit. + Inert/nonhazardous compressed gases will be used in the Manufacturing area [Room 121]. + Product will be transferred through closed piping systems to use locations. + Vessels, piping, systems, location, design and installation will be in accordance with applicable Code requirements. · T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 +General: • Stored upright. • Valves protected from physical damage by means of protective caps, collars or similar devices, • Caps & plugs in place. • Secured to prevent falling due to contact, vibration or seismic activity by one or combination of the following methods: * Cylinders secured ,o a fixed object with 1 or more restraints. * Cylinders secured on a ·cart or other mobile device designed for the movement of compressed gas cylinders. * Cylinders secured within a rack, framework, cabinet or similar designed for such use. • Surface area beneath containers to be constructed of materials compatible with the cryogens/compressed gases. • Containers: DOT approved containers. • Labeling/Marking: Containers marked/labeled identifying contents. · + Pressure Relief Devices: • Provided ta prevent rupture in the event of overpressure. • Per CGA standards. + UFC/CFC 7401 + UFC/CFC 7402 + UFC/CFC 7403 + UFC/CFC75 + OFC/CFC 90: • ANSI A13.1 • ANSI B31.3 • CGAC-7 • CGA P-1 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1]-Page 32 of 47 .. ):-·' ; ... , ; ... ; ... -.-.• ~ ' . ~ ' -' . -~-.. ~ ~ f.lliiilllillil ~· .... f .. , .. ~. Tlt ;rr1 'lli '@Ua r@c·; r---_ INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 19. Compressed Gases I [See previous page.] [Inert/ . Nonhazardous] [continued] NOTE: Owner furnished/installed equipment -not specifically related to building . construction conditions Piping/tubing systems will be submitted for separate plan check/permit 20. Equipment, . Machinery, Containers, Tanks, Vessels & Processes - Hazardous Materials NOTE: Owner furnished/installed equipment -not specifically related to build.Ing construction conditions. + IC Conditions: • General: Owner furnished/installed equipment, machinery, containers, tanks, vessels, processes. • Locations: * Refer to Table 3.0/ltems 2-4, Section 4.0 and · Attachment 1. * Refer to plans submitted separately by others. + Plans: Not intended to be part of this plan check/permit package -plans will be submitted separately by others for separate plan check/permit.. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 +Valves: • General: * Piping system(s) to contain a sufficient number of manual control valves & check valves to operate system properly and to protect the area under both normal & emergency conditions. * Piping in conneetion with pumps to contain sufficient number of valves to control liquid flow in normal · operation and in the event of physical damage or fire exposure. • Backflow Prevention/Check Valves: Provided when · backflow could. create a hazardous condition or cause unauthorized discharge. • Emergency Shut-Off Valves: Identified with a sign/tag. • PiJ!illg Systems: As indicated in Item 14. • General: Equipment, machinery, containers, tanks, vessels &·processes to be approved, listed or otherwise designed and constructed in accordance with approved standards for the intended use. • Plastic Containers -Class I, II & Ill-A Liquids: Containers used for storage of Class I, II & Ill-A Liquids to comply with the following conditions: • Class I & II Liquids: Plastic containers used for storage ·of Class I or II Liquids to be limited to the following conditions: * Containers listed & approved for such storage having the following volume limitations: • 1A Liquids: </=1 gallon • 1B, IC & II Liquids: </=5 gallons * Containers having a capacity of </=16-ounces, as allowed by the Fire Department. • Class Ill-A Liquids: </=5-gallon containers listed & approved for such storage. + UFC/CFC 7401 + UFC/CFC 7402 + UFC/CFC 7403 +UFC/CFC75 t UFC/CFC 90: • ANSIA13.1 • ANSI B31.3 • CGAC-7 • CGAP-1 t .UFC/CFC 7902.1.8 + UFC/CFC 7902.1.11 + UFC/CFC 7902.2.5.10.2.2 t UFC/CFC Table 7902.1-A t UFC/CFC 8001.4.5 Technical Reportrrenant Improvements~ Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 11 -Page 33 of 47 :.-·· L-~ ~-, :.--. ',i_ ~-~ i .. "-~ .. f--~ Qllillaa., ~ ~-~ .. .. INVITROGEN CORPORATION: , 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS -,,liililliiiii --·· ... ~·::.# u-· f:'. ,;-~ .. illliiiiill ~ 21. Fire Extinguishing System Protection • Existing Building/Fire Sprinkler System I • Existing !3uilding/Fire Sprinkler System Conditions: Conditions: Same as IC conditions. + UFC/CFC 1003 + UFC/CFC Table 7902.5-F + UBC/CBC Chapter 9 (904) [continued on next page] T Eriksen-Rattan Associates Inc. • Sprinkler System Design: * Design Density: 0.45 gpm * Design Area: 3,oqo sf • System Size per Floor: <52,000 sf 11st Floor: 48,598 sf; 2nd Floor: 11,975 sf (includes new area)] • Number of Systems in Building: 1. • Waterflow Alarmsr * Outside Building: Waterflow alarm bell or watermotor gong provided outside the building adjacent to system riser. * Inside Building: Audible & visual waterflow alarms provided inside building at a normally occupied location. • Waterflow & Control Valve Monitoring & Trouble Signals: * Waterflow alarm signal transmitted to an approved constantly attended off-site location [i.e.: approved central station], as required by the fire department. * Sprinkler system control valves chained/locked open and supervised/monitored in, in the open position, with trouble signals transmitted to an approved constantly attended off-site location ~.e.: approved central station]. • Emergency Power: Emergency power for waterflow alarms and system monitoring/supervision provided through on-site storage batteries. . • Fire Department Connection: Existing conditions are presumed to com®'. 4719 Palm Avenue, La Mesa CA 91941 + UBC/CBC Std 9-1 [NFPA 13] + UMC/CMC 609.7 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1) -Page 34 of 47 t!III· L_ .. ·-· :... ·/ .... ~ ~ ~--.. ,,_ ~ -UI-.D ., ..... ~ ;:-~ {--~ INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS -,,. ..... <~ r. ..... ~- 21. Fire Extinguishing System Protection + IC E~isting & Tl Conditions:. I t IC ~xisting & Tl Conditions: Same as IC conditions. • General: . [continued] [continued on next page] * Fire sprinkler system design conditions required for tenant improvements and existing areas are as described on the next page. Verification of compliance with the conditions indicated is outside the scope of this report -refer to plans submitted separately by others. * Existing fire sprinkler system design appears to exceed applicable Code requirements for IC's conditions. • Control Area 1 -128/Residual-Waste Chemical P,, Storage: · * Worst Case Design Hazard: • Flammable Liquids 1-B • >5-gallons containers -1 high * Minimum Required System Design: • Design Density: 0.3 gpm • Design Area: 3,000 sf or area of room, whichever is less. • Sprinklers: High temperature -</=1 oo sf per head. .,,. Control Area 2 -140/Raw Material Storage: Same I' ~ as Control Area 1. *II fllll ;;-~ + UFC/CFC 1003 + UFC/CFC Table 7902.5-F + UBC/CBC Chapter 9 [904] 'iliilllillla lalllll!J + UBC/CBC Std 9-1 [NFPA 13] • UMC/CMC 609.7 l' Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1] -Page 35 of 47 :__ ~ ~--~-,., ... I T. 'l 9-·-··g ' l ttilli t --T~-~1 ~ ' .. .. ~ TTL .. i1iiiliiiiiii ~ .. INVITROGEN CORPORATION: 1·soo Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 21. Fire Extinguishing System Protection [continued] l' Eriksen-Rattan Associates Inc. +IC.Existing & Tl Conditions -cor,tinued: • Control Area 3: !I< Class I, II or Ill-A Liquid Storage/Use Areas: • Locations: * Exi~ting Operations: * 109-T.C. Room * 154 -DNA Synthesis * Newm Operations: * 118 -Bulk Solution * 119-Clean Room * 121 -Manufacturing * 138-Custom Services Production Lab • Minimum Required System Design: Same as Control Area 1.. * Other Control Area 3 Areas: • Worst Case Design Hazard: Ordinary Hazard - Group 1. • Design Density: 0.3 gpm • Design Are~: 1,500 sf. • Sprinklers: Ordinary temperature -</=130 sf per head. • Inside & Outside Hose Stream Allowance: 500 gpm -2-hour duration. + Class 1 Product Conveying Exhaust Duct System(s) -Flammabte Vapors: Sprinklers will be installed in exhaust ducts that convey flammable vapors i! the ducts have a cross-sectional dimension >10". Locations where flammable vapors may be present in exhaust ducts are as listed below. The size of exhaust ducts and exhaust ventilation system conditions for these areas is unknown to ERAI. Refer to Attachment 2D for nonflammable vapor exhaust conditions for the areas listed below. • Existing Previously Permitted/Approved Locations: , * 109-T.C. Room * 154 -DNA Synthesis • New Tl Locations: * 1 18 -Bulk Solution/Gel Drying Solution * 119 -Clean Room Bottling/Gel Drying Solution * 128 -Residual/Waste Chemical Storage Room + IC Existing & Tl Conditions: Same as IC conditions. + Class 1 Product Conveying Exhaust Duct System(s) -Flammable Vapors: • Application to IC Conditions: Locations/conditions as indicated in Tl conditions !f the exhaust ventilation conditions addressed in Attachment 2D are not met and exhaust ducts have a cross-sectional dimension >10". [NOTE: Flammable Vapors= Vapor-air mixtures that exceed 10% of LEULFL.] • System Design: * System hydraulically designed to provide 0.5 gpm over an area derived by multiplying the distance between the sprinklers in a horizontal duct by the width of the duct. · * >/=20 gpm discharge per sprinkler from the 5 hydraulically most remote sprinklers. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1] -Page 36 of 47 --.. .. + UFC/CFC 1003 + UFC/CFC Table 7902.5-F + UBC/CBC Chapter 9 [904] + UBC/CBC Std 9-1 [NFPA 13] + UMC/CMC 609.7 ~-- ·-l1!!II ,_ ,. : f' r. f.t;' ---·---"' ··-l.1111!!!!!!!!!19 ~-~~ .. '< ij-,,_ ~ f; .. --... -I -----\ INVITROGEN CORPORATION: 1600 Faraday Avenue, ·Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 22. Portable Fire Extinguishers NOTE: Owner furnished/installed equipment -not specifically related to building construction ~onditions. • General: Dry Chemical [ABC] or CO2 •portable fire extinguishers will be provided throughout the facility. tSize & location: • Class I, II & Ill-A liquids Storage/Use Areas: * locations: . · rD1 _ • Control Area 1: 128/Residual-Waste Chemical r" Storage . Ilk • Control Area 2: Room 140/Raw Material r" Storage • Control Area 3: P1J 118/Bulk Solution ( 109/f.C. Room * 119/Clean Room 121/Manufacturing 11 \ <* 135/Compcell Production r * 137/Fermentation 1-!" * 138/Custom Services Production Lab f ~) * 154/DNA Synthesis \ * Conditions: 4A40BC within 30' of travel, and as follows: ;. Extinguishers located inside each room adjacent to each exit from each room. • Extinguishers located outside each room, . immediately adjacent to exits from each room. • Office, Administrative Emp!oyee Areas :-light Hazard: 2A 1 0BC within 75' of travel. • Other Building Areas: 2A20BC within 50' of travel. t Plans: Refer to plans provided through MJK Architecture & Planning. Same as IC conditions. .. .. r - " - -ziillllliii ~ !i' ~ ... ----•• f,., +UFC/CFC 1002 + UFC/CFC Std 10-1 .. TEriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical ReportlTenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1] -Page 37 of 47 ~ ~ ::--;;; .... ..,. ~ ~---,~ @-~~ -- INVITROGEN -CORPORATION: ;&-~ . -. ·v---~ 7 .. "" , ... -.. ~ , ,, ...... ~ \i;---~· 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS nr ;.,iliilllilliiiia ~ ..... rn~ -. ffa ~-~ J r:-· ¼ - ~tf?,,';_;;,oaai~~oi\aitioif.-;;:0J,;t it~:~11N· ti,fn·~rtnHri'\tfiati' 'ri'Jtton~,tia~1f1,;;,5;~1r,;, Yff:~-i-;:\~;;.'.'.Q'rlf:f~~uWli~ent~"~Go~w..1f.~,~~.;; z,~~:f.>tb0~i'i'oaig:i;,"',:,:,;,rr,rit~ -'-~ ' ~-:1-i-_-,,,:.,--<,,·,• 1 ~-,., ,,,! J.,,,. ...... ,Aw ,,,A~ .,.:;.:,;t;_4,';t, ,·A}'l.'"'':t if)'\ ,J#N,f<J~ i ~ .... ~~!,...$..,i"<M"~ ~~.,~~ ,,. ,.....,w'-!,,,',..-.,, ,.._ "'""' -~· .!J~J,:yt,t"),">,,.,t·lifl;\. , ~_,-.;y~'f~i;L\,..:::.•,_,..~,:...,,_. '1,...,il~~t ..,."'-N·'"°!.U.'1,_.A,~,,;..'liiJp~,;,,_..._"W,,.'".',\™~J!~!J.,..,:.r;,t.,'"· >•'/A%<'· 't~ ,, ,,.,,...,A~ ~~~J~V;~f.JJJ~~~~, -v~Jl~~AA~-i->..s,,., 23. Material Handling & Transportation in Building - Hazardous Materials NOTE: Owner installed/ furnished equipment & conditions --not specifically related to building construction conditions. + Transport of Hazardous Materials in Means of Egress Corridors/Exit Enclosures: Not applicable to IC conditions -no transport of hazardous materials through means of egress corridors or exjt enclosures. • Powered Industrial Trucks/Forklifts: [Conditions unknown to the report preparer.] T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 + Transport of Hazardous Materials In Means of · Egress Corridors/Exit Enclosures: Same as IC conditions· -not applicable. + Powered Industrial Trucks: Powered industrial trucks [forklifts] if used/located inside the building to comply with the following conditions: • General: Powered industrial trucks used to transport Flammable/Combustible to be listed & labeled for use with transport of such liquids. • LPG Powered: * Refueling/exchange of removable fuel containers and repairs done outside the building. * </=2 fuel containers per forklift. * Total water capacity of fuel containers per forklift not to exceed 105 pounds [nominal 45 pound LP-Gas capacity]. * No parking of or unattended forklifts in areas accessible to the public. * No parking of or unattended forklifts in areas of excessive heat or near sources of ignition. * Forklifts not in use to be separated from combustible storage in the warehouse by >/=20' distance. • Battery Powered: * >/=5' to be maintained between battery chargers ar.td combustible storage. · * Battery-charging areas to be conducted in areas in not accessible to the public. * Ventilation to be provided in battery-charging areas to prevent accumulation of flammable gases. * Provide calculations in accordance with OSHA 1910.178 to determine ventilation requirements. [NOTE: Frequently the general volume of the space in which battery-charging areas are located is adequate to maintain vapors from battery-charging operations below their flammable limits.] [Copy of OSHA regulations provided in Attachment 2.] • Repairs: Repairs to be done outside the building, or in an area inside the building specifically approved by the Fire Department. + UFC/CFC 1108 + UFC/CFC 7901.12 + UFC/CFC 8001.12 + UFC/CFC 8203.2.2 +OSHA: • CFR 1910.178 • CFR 1926.403 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 (Rev. 1]-Page 38 of 47 ·..:_· L-tall 15-~--. ,:ma ~-g ..... ~ ~-,: ...... ~ ~ J :. ..... ~ ~ ~ INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad GA. UNIFORM/CALIFORNIA CODES ANALYSIS 24. Storage · Arrangements - Hazardous Materials & General Storage [continued on next page] NOTE: Owner furnished/installed equipment --not specifically . related to building construction conditions. • Hazardous Materials: • General: * Combination of shelf, laboratory cabinet & flammable liquids/hazardous materials cabinet storage. * Lips/guards provided on shelves where individual containers are outside approved flammable liquids/hazardous materials storage cabinets. * Ordinary storage conditions -storage @ </=8' above finished floor. * Approved Storage Cabinets: See Item 27. &I * No high-piled combustible storage conditions. r· ... Room 125 -Shipping & Receiving: See below. ~ Room 128 -Residual/Waste Chemical Storage: * Floor storage -1 drum/container high. * >/=44" aisle to exit access door. pt, Room 140 -Raw Material Storage: * Liquids: <1.-gallon containers to 55-gallon drums. * Solids: <1-pound to 100-pound containers * Floor Storage: 1 drum/1 palleU1 container high * Shelf Storage: Individual containers to <8' above the finished floor * Cabinet Storage: The following materials stored in approved cabinets, with incompatible materials stored in differenUseparate cabinets: • Combustible Liquids II & Ill-A • Flammable Liquids I-B & I-C • Oxidizers 1 & 3 • Unstable Reactives 2 & 3 • Water Reactives 2 * Aisles: As described for 125/Shipping & Receiving on the next page. Sam_e as IC conditions. , s~-,. ~---_ --· flif" 1-'·· .. ·-t .-. -,. 1#---··:· + UFC/CFC 1210.3 + UFC/CFC 8104 + UFC/CFC Table 8104.3-A ~-- TEriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Repo~enant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions-5/11/01 [Rev. 1] -Page 39 of 47 ··-;-:-,;_ ;·.--=----. , J...._ ~ ;_ t .. -~ ~ .. f--~ . -.· ~ .. - . --7---_, --- ~ .. , .. .. ...... ;: 0 ·-· ,_ INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 24. Storage Arrangements - Hazardous Materials & General Storage [continued] :[continued on next page] NOTE: Owner furnished/installed equipment -not specifically related to building construction conditions. +125/Shipping & Receiving: P,..• General: See Table 3.0/ltem 5 -no high-piled combustible storage conditions. • Rack Storage: * Racks: • Single-row. • Steel construction. • Dimensions: * 4' deep x 8' long x </=1 O' high * 3' deep x 8' long x </=10' high • </=5 storage levels/tiers. * Commodities: • Class I-IV commodities -no hazardous materials. • Cartoned & uncartoned products -no palletized storage. * Storage Height: Storage to <12' above the finished floor. ·*Aisles: • Main Aisles: >/=44" • Cross Aisles: >/=24" • Dead-Ends: </=20' • Floor/Palletized Storage: * Commodities: • Class I-IV commodities and finished bulk product bulk solutions. [Largest bulk solutions individual container -1-liter (0.26-gallon)). [NOTE: Finished Product bulk solutions includes one (1) solution classified as a Flammable Liquid I-C and one (1) solutin classified as a Combustible Liquid · 111-A.J • Palletized. • Cartoned. * Storage Height: Storage to <6' above the finished -floor. * Aisles: As described for rack storage above. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Same as IC conditions. + UFC/CFC 1210.3 + UFC/CFC 8104 + UFC/CFC Table 8104.3-A Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code RequirE:ments & Provisions -5/11/01 [Rev. 11 -Page 40 of 47 .. til!I .. tallll ;;·:'--· r··--·-·--r--T (, ]fTt n--w--,., .. ,,iiliiililiiill ---r,r-1 r··-·-·1 ,------f; -f1illiiillilla ...... .. ---. "' INVITROGEN CORPORATION: ~600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 24. Storage Arrangements - Hazardous Materials & General Storage [continued] NOTE: Owner · furnished/installed equipment -not specifically related to building construction conditions. 25. Approv~d Storage Cabinets- Hazardous Materials [continued on next page] NOTE: Owner furnished/installed equipment --not specifically related to bu_ilding construction conditions. + Other/General Storage: • General laboratory, office and building maintenance storage. • Ordinary storage conditions --</=8' high. • Shelf, cabinet, floor storage conditions. • No high-piled combustible storage conditions. + Storage Under Stairs: None -not applicable to IC conditions. + Clearances to Sprinkler Deflectors: >/=18" from top of storage to sprinkler deflectors. + Hazardous materials required by Code to be stored in approved cabinets used for the storage of hazardous materials will be in accordance with applicable Code requirements. +See Item 5, Table 3.0/ltems 2-4 and Attachment 1. ) T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Same as IC conditions. + Flammable Liquids Storage Cabinets: • General: * Signs: FLAMMABLE -KEEP FIRE AWAY -red letters on contrasting background. * Maximum Quantity per Cabinet: </=120 gallons per cabinet. * Doors: Self-closing & equipped with a latch. * Bottom: Liquid tight to a height >/=2". * Type: Cabinets either listed or constructed as described below. • Unlisted Steel Cabinets: * Construction: • Steel -->/=18 gage. • Double walled Pncluding door], with 1-1/2" airspace between ·walls. * Joints: Riveted or welded. • Unlisted Wood Cabinets: * Construction: >/=1" exterior grade plywood. * Joints: Rabbited and fastened in 2 tlirections with wood screws. * Door Hinges: Steel or brass. • Paint: Cabinets painted with intumescent-type paint. + UFC/CFC 1210.3 + l,JFC/CFC 8104 + UFC/CFC Table 8104.3-A + UFC/CFC 7902.5.9 + UFC/CFC 8001.10.6 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions-5/11/01 [Rev. 1)-Page 41 of47 -... :.11111 ..... : ____ ., __ .. v·"'""'·· :rw .. tflil T .. ,, r··-T ~,--,.. 1··''"'· ffe,·1·1 r1u1 "f""l ;lflil -INVIT~OGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 25. Approved Storage Cabinets-· Hazardous Materials [continued] NOTE: Owner furnished/installed equipment -not specifically related to building construction conditions. 26. Premises Identification NOTE: Not specifically related to building construction conditions. 27. Water Supply for Fire Sprinkler System & Fire Flow [See previous page.] Existing previously approved premises identification are presumed to comply. Existing previously approved conditions are presumed to comply. • Hazar~ous Materials Storage Cabinets: • General: * Signs: HAZARDOUS MATERIALS -KEEP FIRE AWAY -red letters on contrasting background. * Construction: Metal construction. * Interiors: Interior treated, coated or constructed of . materials nonreactive with materials stored therein. * Type: Cabinets either listed or constructed as described below. · • Unlisted Cabinets: '* Construction: • Steel -->/=18 gage. • Double walled [including door), with 1-1/2" airspace between walls. * Joints: Riveted or welded. * Doors: Self-closing & self-latching. * Bottom: Liquid tight to a height >/=2". Existing previously approved premises identification are presumed to comply. Existing previously approved conditions are presumed to comply. + UFC/CFC 7902.5.9 + UFC/CFC 8001.10.6 + UFC/CFC 901.4.4 + UFC/CFC 903.2 + UFC/CFC 903.3 + UFC/CFC Appendix Ill-A + UFC/CFC Appendix 111-B ····--·· . T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 _Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1] -Page 42 of 47 ·-·~ tam, .. ·--:··· -· ·--··· ', ~ --.. .. .. -3,---, ....... ~ -. :"] ... .. ... ~ £-.. INVITROGEN CORPORATION: 1600 Faraday Avenue1 Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 28. Fire Department Access NOTE: Some conditions existing & previously approved. Other conditions not specifically related to building construction. ' • Access Roadways for Fire Department Apparatus:' Existing previously approved conditions are presumed to comply. • Access to Exterior Building Doors: Existing previously approved conditions are presumed to comply. • Access to & Access Doors -· High-Piled Combustible Storage: Not applicable to IC conditions -no high-piled combustible storage. • Key Box [Knox Box]: • Key box (Knox Box] will be provided and located as required by the Fire Department. . • Box will contain keys to gain necessary access and . other information as required by the Fire Department. • Document Vault [Knox Vault]: • Document vault [Knox Vault] will be provided and · located as required by the Fire Department. • Vault will contain plans, hazardous materials information and other information as required by the Fire De_eartment. l' Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 • Access Roadways for Fire Department Apparatus: Existing previously approved conditions are presumed to comply. • Access to Exterior Building Doors: Existing previously approved conditions are presumed to comply. • Access to & Acces~ Doors -High-Piled Combustible Storage: Same as IC conditions -not applicable. • Key Box [Knox Box]: Same as IC conditions· __ as r~quired and approved by the Fire Department. • Document Vault [Knox Vault]: Same as IC conditions -as required and approved by the Fire Department. + UFC/CFC 901.4 · + UFC/CFC 902.2 + UFC/CFC 902.3 + UFC/CFC 902.4 + UFC/CFC 8102.6 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1]-Page 43 of 47 .. ·::iiiliia ,__... t..... : ... -,_;...._ . ~ ··,ra ~ 'i:111111 :1f"~. q--·-... tfT ~ ---;,-,,-. ~ .. tl-'"l ,-n-Y·, c·t'-"•O• { ... , .• .. INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS ,,·,._,,j,;'.-~t(.Qc,(fe;~Q~OdicJ'IDlZ,'f,§":. aI:~'7,;i,1Ji~ftr,o~e~fr'.f*i!~Q.l,af15"rifQhri'fj1':i01i~i·:~~,°:;:} Jt:::'f-~:l;.'.nfi';iji:f@Dtf!=q· ll1tef"~ "T°sfR:\"·~ .. ri'.lSfliO~~{cj';,N~';~ff: }}(;'~~fijflli'ii1IIJ?hjftpi~+7'->1_;:.'$ ,.-~'';'i$i'}{~\.' !< .,,.. -:,,.,,..,.....,,_,..,,.,,.,, ,,,.~-7.-~~-$?;¼.-..~8~, ~-P,,,; =-~,v..i ~~-fl~,,,~ ...... ', "%9,l/!ts~~~-,;t"~vf8;)J .... ~f} ~,-,}M-,.~~N_,,,~!,\!,!~~b~,.~~-.s~;) ffi,_,:h{?°:¥;:,TJ~~ ,-., N .ti!-1\ ... ,, .. ,,. ~-' .... ..;f\,. ~-~ -,.~~--ltt.,___...e:-~;..{""').~i;"".¼-¼''-""/4;-,,:I.I, ::~f.,j~1~.,t1{t~~ ~~, ,._r ...... ~~~J,,:;;{i 29. Hazard Identification Signs NOTE: Owner furnished/installed equipment -not specifically · related to building construction conditions. Hazard identification signs will be provided in · accordance with applicable Fire Department requirements. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 +General: · • Hazard identification signage may be required by the • UFC/CFC 8001.7 Fire Department. •. Signs, if required, are normally required to be placed in the following locations: . * At entrances to and within each area where hazardous materials are located. * On vessels involved with liquid transfer operations. • Signs are generally required to be in accordance with the following: ' * Measure 15-inches on each side. . * Have white reflective letters/numbers on blue or red backgrounds and black reflective letters/numbers on white and yellow backgrounds. + Hazard Identification: • General/Building Hazard Identification: .* Health: 4 * Flammability: 3 * Reactivity: 3 * Special: COR OX WR • Control Area 1 Hazard Identification: * ·Health: 3 * Flammability: 3 * Reactivity: 0 * Special: COR • Control Area 2 Hazard Identification: * Health: 4 * Flammability: 3 * Reactivity: 3 * Special: COR OX WR • Control Area 3 Hazard Identification: * Health: 4 * Flammability: 3 * Reactivity: 2 * Special: COR OX WR • Material Specific Hazard Identification: Refer to Attachment 1. • Compressed Gases: Areas where compressed gases are located to have signage outside & inside the areas indicating "COMPRESSED GASES". Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions-5/11/01 [Rev. 1)-Page 44 of 47 ;_.. r----~ ::-;r,-.. -.-~---· .. ,,1··--i :1···--, 11., .. ,.. TS"'~I ···r·ra -t ..... , .. -? ..... T rr·---, ., ... 'ii ,..._ ~ .,,. ..... --INVITROGEN CORPORATION: 1600 Faraday-Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS (;;;,;;-;;-:::;~it~;t-:;l'.Srun~m-;-oY~~j\;q>!;,£>: J:,:;,,·,;;&~Pr'n";itHr;g" drf.'ri~~,__o~,t~~~n"'tilit~~~¾;,y;jof~flt.;''-t>,'-5£~,\;;.£<(;'-,~~ri'.i.'ii'ie"t."Bf/i';{~<·1·r~m-·e·~t""' -~cr~~gi11~lis·'(,;.tf;j¢::.,i,;,:.~;1:;,1;,;;,,,i;rs.,~QOltlW91g.(' ~7-1.!tiJ&~~~~~-~,.bt~*:.~d¼ ~411~&~,No/~,,--~~~~ !!!'.,!!!P.~~t..-:-<",i~ ~-,,0~~~0:!-:wi,,N~,~'<; t.:4~..t~ 1$; .. ~.Jt>::i:~ :~¾·'i~~~J~~~--,~=-~,:e;t~ , ? 4-;_,~v .... !Jd'_... ... ,~%~.:i~&:i,tJ~ ~-JfM'2t.fi~r ~--~ - 30. Emergency Response, Training & Procedures · [continued on next page) NOTE: Owner furnished/installed equipment, etc. -not specifically related to building construction conditions. + Materials Safety Data Sheets [MSDS]: MSDS will be maintained on-site in a location acceptable to the Fire Department. + Hazardous Materials Inventory Statements [HMIS]: Inventory information provided in Attachment 1. + Personnel Training & Written Procedures: • Employees will be trained to be familiar with the . chemical nature of the materials and appropriate mitigating actions necessary in the vent Qf fire, leak or spill. • Persons will be designated & trained to be liaison personnel for the Fire Department as determined to be necessary by the Fire Department -i.e.: aid Fire Department in preplanning emergency responses & identification of hazardous materials locations/conditions. + Emergency Equipment: Provisions will be made for controlling/mitigation leaks/spills [i.e.: clean-up materials, disposal procedures, etc.]. + Hazardous Materials Management Plan [HMMP]: Hazardous Materials Management Plan, if required, will be provided in accordance with applicable Code requirements. +.Materials Safety Data Sheets [MSDS]: Same as IC conditions --location to be approved by Fire Department. + Hazardous Materials Inventory Statements [HMIS]: Same as IC conditions. • Personnel Training & Written Procedures: Same as IC-conditions, as required by the Fire Department. + Emergency Equipment: Same as IC ,conditions. +Hazardous Materials Management Plan [HMMP]: To be provided as required by the Fire Department and and/or other agencies. Plan to include the following . information, in addition to other information that may be required by the authorities having jurisdiction: • General Information: Business name, address, emergency contacts, business activity, owner or operator, SIC code, number of employees & hours., signature of designated representativ~. • Site Plan: * Drawn to scale. * Location of location of building, exterior storage facilities, permanent access ways & evacuation routes, parking iots, internal roads, chemical loading & loading areas, equipment cleaning areas, storm & sanitary sewer accesses, emergency equipment & adjacent property lines. ·• Building Floor Plan: * Drawn to scale. * Hazardous materials storage & use areas, rooms, doorways, corridors, means of egress and evacuation routes. * Contents of storage areas identified. + UFC/CFC 8001 .3 + UFC/CFC App. 11-E +OSHA: • CFR 1910.178 • CFR 1926.403 ,.l • T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 Technical Report/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1)-Page 45 of 47 clllll Laa ,··---·-=-,,_ ~ ... -~-, ... ~ ?ffl'J tr·----, .. :J_--.. ~ ~ ... u··--'l""""' " -c:,__. ~ ;:liliiiiila ~ ~ ,_ '}ti INVITROGEN CORPORATION: 1600 Faraday Avenue, Carl~bad CA . . UNIFORM/CALIFORNIA CODES ANALYSIS 30. Emergency I [See previous page.] Response, Training & Procedures [continued] NOTE: Owner furnished/installed equipment, etc. -not specifically related to building construction conditions. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA 91941 • Hazardous Materials Management Plan [HMMP] - continued: • Hazardous Materials Handling: * Description of ~ctivities involving handling of hazardous materials between storage & manufacturing areas. * Information showing how such operations are conducted to prevent accidental release of hazardous materials. • Material Compatibility & Separation: Identification of controls used to ensure separation of materials & conditions incompatible with each other. • Monitoring Program: Description of monitoring methods used re types and amounts of hazardous· materials on-site. • Inspection & Record Keeping: Written procedures for schedules & procedures for inspecting· safety & monitoring and emergency equipment. • Employee Trai11ing: Written procedures for employee training to prepare employees to safely handling hazardous materials on a daily basis and during emergencies --i.e.: * Instructions in safe storage & handling of hazardous materials, including maintenance of monitoring records. * Instructions in emergency procedures for leaks, spills, 'fires or explosions, including shutdown of operations & evacuation procedures. * Record-keeping procedures for documenting employee training. • Emergency Response: Written description of facility emergency respQ__nse procedures. + UFC/CFC 8001 .3 + UFC/CFC App. 11-E +OSHA: • CFR 1910.178 • CFR 1926.403 Technical Repc;irt/Tenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 (Rev. 1)-Page 46 of 47 ·_.... 1 ,-0·---r· · 1 I~~~'"'• slllliliiill ~ Xf ''·-. · :1·1··--1 --.. -~r-·• ~;('"tt r, ...... ,_ 1rr, ~ t .. -.. i··-c,-~-• .. INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 31. Special Use Fire Department Permits & Plans NOTE: Not specifically related to building construction conditions. + Special use Fire Department permits will be ·obtained as required by the Fire Department. T Eriksen-Rattan Associates Inc. 4719 Palm Avenue, La Mesa CA.91941 +Hazardous Materials Conditions: Permits and plans may•be required by the Fire Department. If required, the following information is generally required to be · provided: • Building floor & outdoor plans showing locations of hazardous and conditions of operations involving hazardous materials. • Locations of emergency isolation and mitigation valves & devices. • Product conveying piping containing hazardous materials liquids or gases. • On & off positions of valves for valves which are of the , self-indiqating type. · • Type and design of fire-extinguishing systems. • Location of valves· controlling water supply of sprinklers. · • Storage Conditions: Permits and plans may be required by the Fire Department. + 1;:gress Plans: Fire Department may require that approved egress plans be posted throughout the building_. + UFC/CFC 4501.3 + UFC/CFC 6202 + UFC/CFC 7901.3 + UFC/CFC 8001.3 + UFC/CFC 8101.3 Technical ReporVfenant Improvements -Hazardous Materials & Storage Operations Code Requirements & Provisions -5/11/01 [Rev. 1) -Page 47 of 47 Ii IJ Ill I IJ -I\ 11· I. ·1· I I II 1·· I I I I I Ii INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 11 May 2001 [Rev.1] Prepared· by Y Eriksen-Rattan Associates Inc. 4719 Palm Avenue · La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net This report is the property of Eriksen-Rattan Associates Inc. and wa~ prepared exclusively for use by lnvitrogen Corporation for the operations described in this report. Copies of this report retained by lnvitrogen Corporation shall be utilized only by them for occupancy classification and the Uniform/California Code conditions addressed in this report. This report shall not be used for the purpose of construction for.this project or any other project or for any other purpose. -I I I I I. I I I I I I :I I ·I I I I I l1 INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA . UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net I I I I I I I I I .I ;I 1 :1 \ 1.-· '.I :I .I I I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by T Eriksen-Rattan Associates Inc. -.... 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net . , __ l .. , ... :, ... ~ :-----~ {. -----, ,. q.N .• -u--~a ·- HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS 'ffTI ~ ' I...._ ~ ... ~ ~ UBC/CBC TABLE 3-D -UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY • PHYSICAL H~ZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 1 -Room 128/Residual-Waste Chemical Storage STORAGE USE CLOSED Solids Liquid Gas Solid Liquid Material Lbs Gins Cf Lbs Gins Flammable Liquids I-B 90.0000 --- Oxidizers 1 30.0000 r~-,, • .. .. Gas Solid Cf Lbs 1997/1998 CODES-CONTROL AREA 1: .Bl OCCUPANCY CONDITIONS BASED ON THE USE and STORAGE OF PHYSICAL HAZARD MATERIALS. Liquids: Transfer from </=20-llter vessels into storage vessels. Solids: Transfer of </=1 O pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. . .• ---·-··, .•... ,.. USE OPEN Liquid Gins 2.0000 1.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 1 r·--·1 rr·- Gas Cf - . i -:-.a ,;; ... -' lallaa ~ ~ ; ____ ~ ~ -·-.-. ,:······· ~--ti ,,-~. ,:--. ~ ~ ~l ·'·; t Jfiil .. .. l ~,, .. ~; ,., r·1 511it f---,r, -. HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-D • UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY· PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA.· Control Area 1 -Room 128/Residual-Waste Chemical Storage fllimfli ;,.,,_, .. , • .., ... a:.11;, ~"'-,,. , ·-,g .. ,.,,, -1 .,. ,;y,-,,,,r7'!Jl',,,,!/'IF""· -,.,,,ii'l"lf!.'7' ~l'!,Ji~M~~lt~9Y,J~7~ ~~ifl!'~:t'~it~-~1R ~~~T~?.0.::~~~ ¾St;.;P"'"ei' [-,;-~~\!f~~ ~ ~ TOTAL Flammable Liquids 1-B [LIQUIDS] AGGREGATE TOTAL Flammable Liquids 1-B [LIQUIDS]: 90.0000 Gins 92.0000 GALLONS LIQUIDS HAVING FIRE POINTS -1997 UBC TABLE 3-D/UFC TABLE 7902,5-a EXEMPT AMOUNTS PER CONTROL AREA: STORAGE & USE CLOSED • H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. USE OPEN·& PRESSURIZED SYSTEMS >15 PSIG • H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: 120 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT· WITH CABINETS: 240 GALLONS USE CLOSED EXEMPT AMOUNT: 120 GALLONS USE OPEN EXEMPT AMOUNT: 30 GALLONS LIQUIDS WITHOUT FIRE POINTS • 1997 UBC TABLE 30D/UFC TABLE 7902.5-A, 7901.1.1/Exceplion 9 EXEMPT AMOUNTS PER CONTROL AREA: STORAGE: UNLIMITED USE CLOSED EXEMPT AMOUNT: 120 GALLONS USE OPEN EXEMPT AMOUNT: 30 GALLONS MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1/EXCEPTION 3: </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS <1=4 LITERS: UNLIMITED GROUP M OCCUPANCY· MAXIMUM QUANTITIES PER CONTROL AijEA • UFC TABLE 7902.5-B • COMBINATION 1-B, 1-C, II, Ill-A: CEILINGS </=18' HIGH -</==6'. SHELF STORAGE, </==4.5' OTHER STORAGE: 7,500 GALLONS SPECIAL SPRINKLER SYSTEM PROTECTION: 15,000 GALLONS ) ,,N,.,.,EW,;t\l,c'.\,Xb',e1¥,,t.-.,,:s-_,,,_¾i f:\ll:totst•e, f:'Rti•tsli ~~;rt.l 'o/oiR-1u .. ~ , 11~1 r-.,,.f "'"f"'I· -,~·.,.;;:.-...... _,~.s,:~,·»;-:-,l'¼'' ·· ··,;,,, '" ~~--~_£~-i~2l\i:~:i~::~~q~-¥~J7;,ttf]JV~fK~1f:gf3;~1:?(~~~iJ TOTAL Oxidizers 1 [LIQUIDS] AGGREGATE TOTAL Oxidizers 1 [LIQUIDS]: 30.0000 Gins 31.0000 GALLONS 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA• H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: 8,000 POUNDS+ 800 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT· WITH CABINETS: 16,000 POUNDS+ 1,600 GALLONS USE CLOSED EXEMPT AMOUNT: 8,000 POUNDS+ 800 GALLONS USE OPEN EXEMPT AMOUNT: 2,000 POUNDS+ 200 GALLONS 1¥,;ir,lh·-t·ffl r•-.1~1 t-i)~~~~~ ~,,J,)_1,~; 0.0000 Gins -~1 &fJlil 0.0000 Gins. 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY· EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 36,000 POUNDS+ 3,600 GALLONS 1999 UFC SUPPLEMENT· RETAIN/WHOLESALE STORAGE/DISPLAY· EXEMPT AMOUNTS PER M/S OCCUPANCY CONTROL AREA: SAME AS 1997 UFC 1999 UFC SUPPLEMENT -S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 36,000 POUNDS + 3,600 GALLONS CONTROL AREA 1: 51 Occupancy Conditions. Building is protected thr01,1ghout by an automatic fire sprinkler system. Liquids: Transfer from </=20-liter vessels into storaQe vessels. Solids: Transfer of </=10 pounds into storage vessels. 1::::·~-.,,{;ji,i.l·m P)~j~,, ~-a;fi; . .,l)gl.,~· 2.0000 1.0000 Gins ~ ~ Gins SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC.· 04/223/2001 -PAGE 2 '{'"1 __ L_:_... ...... ------·----~---------- HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E -UFC/CFC TABLE 8001.15-B SUMMARY· HEALTH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 1 -Room 128/Resldual-Waste Chemical Storage Material Carcinogens Corrosives Irritants Other Health l;f azards Solids Lbs 300.0000 300.0000 300.0000 STORAGE Liquid Gins 60.0000 -- 90.0000 --- 60.0000 --- 90.0000 Gas Cf Solid Lbs USE CLOSED Liquid Gins Gas Cf Solid Lbs 1.0000 1.0000 1.0000 1997/1998 CODES -CONTROL AREA 1: S1 OCCUPANCY CONDITIONS BASED ON THE USE and STORAGE OF HEALTH HAZARD MATERIALS. Liquids: Transfer from </=20-liter vessels Into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. USE OPEN Liquid Gins 2.0000 - 3.0000 -- 1.0000 -- 3.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 • PAGE 3 Gas Cf ...... L ...... .. --y-u .. ·rt II 1 ..... ~ :;.---,-, 1rT·1 ~rru ,,.r, ,., .. -,.: _. ~-----,--, TTi HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E -UFC/CFC TABLE 8001.15-8 SUMMARY -HEAL TH HAZARD .MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 1 -Room 128/Residual-Waste Chemical Storage TOTAL Carcinogens [SOLIOS] AGGREGATE TOTAL Carcinogens .[SOLIDS): TOTAL Carcinogens [LIQUIDS] AGGREGATE TOTAL Carcinogens [LIQUIDS): CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE 8001.15..S: 1997 UBC TABLE 3-E/U,FC TABLE 8001.15-B EXEMPT AMOUNTS: ~~tt~~!i!~§~~~ft~~1r~Iz~~~Zft4I$:~~ TOTAL Corrosives !LIQUIDS) AGGREGATE,TOTAL Corrosives [LIQUIDS]: UNLIMITED G~•g1·~~ t~I ;{~:rml: ~,'<V , ' 300.0000 301.0000 POUNDS Lbs 60.0000 Gins 62.0000 GALLONS UNLIMITED -WITH SPECIAL CONTROLS ~~ ~,S,.,,; "'!,I~. l'tcw~r·,,1 Mrrl;, 90.0000 Gins 93.0000 GALLONS 1997 UBC TABLE 3-E/UFC TABLE 8001.15·B EXEMPT AMOUNTS PER CONTROL AREA -H-7 OCCUPANCY REQURIED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 10,000 POUNDS+ 1,000 GALLONS & 1,620 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 20,000, POUNDS+ 2,000 GALLONS & 3,240 CUBIC FEET USE CLOSED EXEMPT AMOUNT: 10,000 POUNDS+ 1,000 GALLONS & 1,620 CUBIC FEET USE OPEN EXEMPT AMOUNT: 2,000 POUNDS + 200 GALLONS r-::0'fir,;;::,;,,..;, I ~t&~~lOT~-: 0.0000 0.0000 ~,~~~ 0.0000 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 19,500 POUNDS+ 1,950 GALLONS 1999 UFC SUPPLEMENT -RETAIL/WHOLESALE STORAGE/DISPLAY· EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 20,000 POUNDS+ 2,000 GALLONS 1999 UFC CUPPLEMENT -S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 20,000 POUNDS+ 2,000 GALLONS CONTROL AREA 1: 51 Occupancy Conditions. Building is protected throug~out by an automatic fire sprinkler system. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. ~ ,;, ii'''''•t!G'i"~';i ,<"~~-.& !..~ , ,..fi:i.\~ Lbs 1.0000 Gins 2.0000 ~ ' 1r11~·~, ~1i5 --~~ Gins 3.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 4 ~ ' Lbs Gins Fiwffl Gins ~--!'.-· ~ JIii .. JIii· .. ..,. . ) .. HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS i,illllilllii ~ f .. 71·1 ,_ r7r; . r·--,·ua UBC/CBC TABLE 3-E -UFC/CFC TABLE 8001.15-B SUMMARY -HEALTH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 1-Room 128/Resldual-Waste Chemical Storage ·1m-;;.-,•i.!J/Po'~t'-,~1~J/$\?4'9~~:~i:;:-§PtJ/'-J~o/~,¥~·1i'VJ,zJ~-~v~~~...,.,/!l~~~ ,_, --,i~ .. ~'S&i"Et:$.i~-b,:~-~.~;:,~1,~,1¾;'!,~\~;:_7:,.~~~i:-)·~1€~~~~.~-it~~~f;tf,;~k TOTAL Irritants [SOLIDS] AGGREGATE TOTAL Irritants [SOLIDS]: TOTAL Irritants !LIQUIDS] AGGREGATE TOTAL Irritants (LIQUIDS]: CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE 8001.15-B: 1997 UBC TABLE 3-E/UFCTABLE 8001.15-8 EXEMPT AMOUNTS: STORAGE/AGGREGATE EXEMPT AMOUNT: USE CLOSED EXEMPT AMOUNT: USE OPEN EXEMPT AMOUNT: TOTAL Other Health Hazards [SOLIDS] AGGREGATE TOTAL other Health Hazards [SOLIDS]: TOTAL Other Health Hazards [LIQUIDS] AGGREGATE TOTAL Other Health Hazards [LIQUIDS]: CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE'8001.15-B: 1997 UBC TABLE 3-E/UFC TABLE 8001.15-8 EXEMPT AMOUNTS: STORAGE/AGGREGATE EXEMPT AMOUNT: USE CLOSED EXEMPT AMOUNT: USE OPEN EXEMPT AMOUNT: CONTROL AREA 1: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. UNLIMITED UNLIMITED UNLIMITED f1!~Jjl} 300.0000 301.0000 POUNDS ~ ~ Lbs 60.0000 Gins 61.0000 GALLONS UNLIMITED -WITH SPECIAL CONTROLS UNLIMITED UNLIMITED UNLIMITED 1 · Stlir"'"''''I s-=.,id~.9.~ l\9Ji1~1 300.0000 Lbs 301.0000 POUNDS 90.0000 Gins 93.0000 GALLONS UNLIMITED -WITH SPECIAL CONTROLS Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. TTJ ~ . ·.: ' -rr · ~,,,."-• <--~ 11t,q~1 !~tig:~ 0.0000 Lbs 1.0000 0.0000 Gins 1.0000 $i1FiJMGtt"',, r,(~:'~~-""~'!j·~.'b~ 1;9!t~i -i ~zU,i~!l 0.0000 Lbs 1.0000 0.0000 Gins 3.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 5 .. .. Lbs Gins II!!) . . Lbs Gins I I I I I I I I I I I ·,1 I I 1: I I ,, I' INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by "Y Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net : __ : .... ' ~ ,,_ ~ ... i:.111 ~-. ~ .. ,, ...... ~· "-~ .. .. ---..... ,~· .. .. .. . ;;-~ lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 1 -Room 128/Residual-Waste Chemical Storage: Hazardous Materials Inventory 1 2001-000-132 " 100 Residual/Waste Halogenated Liquids CA, CR, OHH, P65 30,0000 Gins 0.0000 Gins 1.0000 Gins CA 1-128/Chemical [Dichloromethane/75-09-2, Storage [Existing] Trichloroacetic Acid/76-03-9) - 2 2001-000-133 L 100 Residual/Waste Nickel Chloride/Silver CA,CR,OHH, 30.0000 Gins 0,0000 Gins 1.0000 Gins CA 1-128/Chemical Nitrate Liquids [Nickel Chloride/7791-20-OX1,P65 Storage [Existing] O; Silver Nitrate/7761-88-8; Solvents] [FP: None 3 2001-000-131 L 100 Residual/Waste Non-Halogenated High FL1B, IR 60.0000 Gins 0.0000 Gins 1.0000 Gins FLV CA1-128/Chemlcal BTU Liquids [Acetonttrile/75-05-8, Storage [Existing] Tetrahydrofuran/109-99-9, Pyridine/110- 86-1, et al] [HR: H2 F3] 4 2001-000-135 s 100 Residual/Waste Non-RCRA Dry Waste CA,IR,OHH 300.0000 Lbs 0.0000 Lbs 1.0000 Lbs CA 1-128/Chemical [Solids contaminated with Phenol/108-95-Storage [Existing) 2, Chloroform/67-66-3, Ethidlum Bromide/ti39-45-8, el al] [HR:H2] 5 2001-000-134 L 100 Residual/Waste Organic Low BTU CR, FL1B, OHH 30.0000 Gins 0.0000 Gins 1.0000 Gins FLV CA 1-128/Chemlcal Solvents [EthanoV64-17-5, Methanol/67-Storage [Existing] 56-1, AceticAcid/64-19-7, etal](HR: H3 F3] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLY-Combustible Liquid Vapor. FLY-Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS • ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 • PAGE 1 - -1 I I I 1· ,, I I ·1· I I I t 1- I I I 'I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net I :I I '.I I I I I :I f I ,·, I I I I I I I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX-619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net ; ' ~--j_ .I ,:·-,, =· Ll!W tl!!!!!II .. .. ' HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS 1:-~ ~ '.-'-~ - UBC/CBC TABLE 3-D -UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY -PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage STORAGE USE CLOSED Solids Liquid Gas Solid Liquid Material Lbs Gins Cf Lbs Gins Combustible Dusts 0.5304 Combustible Liquids II 26.9620 --- Combustible Liquids Ill-A 0.3170 --Combustible Liquids 111-B 39.2500 - Flammable Liquids 1-B 142.5709 Flammable Liquids 1-C 1.0567 Flammable Solids 0.4420 -Oxidizers 1 28.7300 0.2641 Oxidizers 3 1.6575 Unstable Reactives 1 0.0066 liaalli --.. Gas Cf ,-:.-~ .. Solid Lbs .. .. USE OPEN Liquid Gins to...-~ Gas Cf • .. ··- ------------------------------------------------------------------------------------------------Unstable Reactives 2 0.4420 0.4755 Unstable Reactives 3 1.1603 Water Reactives 1 19.2270 5.4227 Water Reactives 2 2.0443 1.0567 1997/1998 CODES -CONTROL AREA 2: S1 OCCUPANCY CONDITIONS BASED ON THE STORAGE OF PHYSICAL HAZARD MATERIALS. Storage only -no use conditions. Building is protected throughout by an automatic fire sprinkler system. SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 1 r_. . · r I ~.11111 ·--[ ~ ~-i,--~ ~ 3 j 3 f ,I ii-·;:,~ ~~ u ]·--- HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3,D-UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY-PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage i",j:)ffi!}jjjt161l..lpW$'i..~;',;~~l'.;~;%frl$f§j;:;§.)l"~'jS:)1J;~\<\w;,::;fl ~ ,, • ~ ....... ,.,~si-ss ,~·: ,.,..~. tJ!~t,; 1>:7;l;~t1'i\~<~J.v.¾';i., ~•J-:8..,4isY·{,~~'k'Y-cr-.b~ 'f:¢. ,.,,.,# ,i1>-''-.o:: fisSlli'¢.iB~~1 u. ·~-~.rg~:-ey; l!gm~ TOTAL Combustible Dusts [SOLIDS] AGGREGATE TOTAL Combustible Dusts (SOLIDS]: 0.5304 0.5304 POUNDS Lbs H OCCUPANCY NOT APPLICABLE -NO FIRE/EXPLOSION HAZARD POTENTIAL ASSOCIATED WITH USE/STORAGE CONDITIONS. 1~i' T'~ f'~qtj ~ij~}?~9,J !~llL,.v: TOTAL Combustible Liquids II (LIQUIDS] AGGREGATE TOTAL Combustible Liquids II (LIQUIDS]: 26.9620 26.9620 GALLONS LIQUIDS HAVING FIRE POINTS -1997 UBC TABLE 3-D/UFC TABLE 7902.5-A EXEMPT AMOUNTS PER CONTROL AREA: STORAGE & USE CLOSED -H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. USE OPEN & PRESSURIZED SYSTEMS >15 PSIG • H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 240 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 480 GALLONS USE CLOSED EXEMPT AMOUNT: 240 GALLONS USE OPEN EXEMPT AMOUNT: 60 GALLONS LIQUIDS WITHOUT FIRE POINTS -1997 UBC TABLE 30D/UFC TABLE 7902.5-A, 7901.1.1/Exception 9 EXEMPT AMOUNTS PER CONTROL AREA: STORAGE: UNLIMITED USE CLOSED EXEMPT AMOUNT: 240 GALLONS USE OPEN EXEMPT AMOUNT: 60 GALLONS MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1.1/EXCEPTION 3: </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED GROUP M OCCUPANCY -MAXIMUM QUANTITIES PER CONTROL AREA -1997 UFC TABLE 7902.5-B • COMBINATION 1-B, 1-C, II, Ill-A: CEILINGS </=18' HIGH -</=6' SHELF STORAGE, </=4.5' OTHER STORAGE: 7,500 GALLONS SPECIAL SPRINKLER SYSTEM PROTECTION: 15,000 GALLONS CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only --no use conditions. Gins * ... •• --·:1·· · · ~r···1 ,;---·--··· :£ 'r~". C~'ilii f;ttwlffl _,.v,,~,'lr.).."M""'-i, . ~V', ', ... :-i ~~~J{t1:: ml) - 0.0000 Lbs 0.0000 Lbs r~.$:fl~->!,1 ~ ~-w$:M1.?'1i,~-~~ ~ )>cj";n-ffii~ ~ ,;~~1'!--fr..,1,#·f ~ 0.0000 Gins 0.0000 Gins SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS-ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 • PAGE 2 ~---.• ··-,, ~-;._ = -~ &1111 i_-~-"'!§,-~ 'To!!!! , ,,._ ~ le-%-t4!!!1111111 ~--~ l -- HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-D-UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY -PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2-Room 140/Raw Material Storage sitrfl[Q.ii~im!1~9!f@t!m~~~;~~ID'feifk?;{¥11 m~rtifQ1I 11''"iUI ,~ ..... % .... 9.5'.Ll ,!"".M .• TOTAL Combustible Liquids Ill-A [LIQUIDS] 0.3170 Gins AGGREGATE TOTAL Combustible Liquids Ill-A [LIQUIDS): 0.3170 GALLONS LIQUIDS HAVING FIRE POINTS -1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA: STORAGE & USE CLOSED. H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. USE OPEN & PRESSURIZED SYSTEMS >15 PSIG • H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 660 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: . 1,320 GALLONS USE CLOSED EXEMPT AMOUNT: 660 GALLONS USE OPEN EXEMPT AMOUNT: 160 GALLONS LIQUIDS WITHOUT FIRE POINTS -1997 UBC TABLE 30D/UFC TABLE 7902.5-A, 7901.1.1/Exceplion 9 EXEMPT AMOUNTS PER CONTROL AREA: STORAGE: UNLIMITED USE CLOSED EXEMPT AMOUNT: 660 GALLONS USE OPEN EXEMPT AMOUNT: 160 GALLONS MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1.1/EXCEPTION 3: </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED GROUP M OCCUPANCY. MAXIMUM QUANTITIES PER CONTROL AREA -1997 UFC TABLE 7902.5-B • COMBINATION I-B, I-C, II, Ill-A: CEILINGS </=18' HIGH-</=6' SHELF STORAGE, </=4.5' OTHER STORAGE: 7,500 GALLONS SPECIAL SPRINKLER SYSTEM PROTECTION: . 15,000 GALLONS ·---~"······*·· ""--.. .,_,_,.,¾,·,•~~«·-,A,,~n~~n.o·-"-"H"-·"" -,~$-f-. .,~-.,,,e-·it (1u,ai.,J :,l...,-,?.~.IL.J ld.11!':t, TOTAL Combustible Liquids 111-B [LIQUIDS] AGGREGATE TOTAL Combustible Liquids 111-B [LIQUIDS]: 39.2500 Gins 39.2500 G_ALLONS 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA-H OCCUPANCY NOT REQUIRED IN SPRINKLERED BUILDING. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: UNLIMITED STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: UNLIMITED USE_ CLOSED EXEMPT AMOUNT: UNLIMITED USE OPEN EXEMPT AMOUNT: UNLIMITED MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1/EXCEPTION 3 • . </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only --no use conditions. ·····- , ... --. <,: ~-. _--· ~r:·_- ~'i~-u~~ ,~, wl\,o;_,. ,...1tll:1!i:: 1111 = t'"*':·~~v~lf :~--=-,~ +12:A: 0.0000 Gins 0.0000 ~kle'~'il -~-w•i ,,:;.:~ ;-, ~ , 1~1i9Jl{iel 0.0000 Gin~ 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 3 \§ ..... . ~ . Gins mmll - Gins $'--~ ;_,, __ :_ ~-~~ -,;;-~ '.--,:-~---~ ... r,--~ HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS t-~ Ii--~~ l-<:::_:;.;---.. UBC/CBC TABLE 3-D -UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY· PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage ~,~g[l!i~!!![Alm~@~~~~,?~i~~~~~~-~~, TOTAL Flammable Liquids 1-B [LIQUIDS] ~to'""'~ &'~,-,,.J1~~,, 142.5709 --1 ~ ~ Gins AGGREGATE TOTAL Flammable Liquids 1-B [LIQUIDS]: 142.5709 GALLONS LIQUIDS HAVING FIRE POINTS -1997 UBC TABLE 3-D/UFC TABLE 7902.5-a EXEMPT AMOUNTS PER CONTROL AREA: STORAGE & USE CLOSED -H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. USE OPEN & PRESSURIZED SYSTEMS >15 PSIG -H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 120 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT-WITH CABINETS: 240 GALLONS USE CLOSED EXEMPT AMOUNT: 120 GALLONS USE OPEN EXEMPT AMOUNT: 30 GALLONS LIQUIDS WITHOUT FIRE POINTS -1997 UBC TABLE 30D/UFC TABLE 7902.5-A, 7901.1.1/Exceplion 9 EXEMPT AMOUNTS PER CONTROL AREA: STORAGE: UNLIMITED USE CLOSED EXEMPT AMOUNT: 120 GALLONS USE OPEN EXEMPT AMOUNT: . 30 GALLONS MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1/EXCEPTION 3: </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED GROUP M OCCUPANCY-MAXIMUM QUANTITIES PER CONTROLAREA-UFC TABLE 7902.5-B-COMBINATION 1-B, 1-C, II, Ill-A: CEILINGS </=18' HIGH -</=6' SHELF STORAGE, </=4.5' OTHER STORAGE: 7,500 GALLONS SPECIAL SPRINKLER SYSTEM PROTECTION: 15,000 GALLONS {'.,:_.,.,._~,,,.n~-,,J.,.(,'~,..~{,'1':t,-i.~,:,£-:-.~.iZ'-f:.:--~f---,~ff.f~-:,.:a·"'·«qft~,,..,JJ_,,t;,.~J:.½) -;1-Y{~,·.~1h ;1y,; ,<,,/,, .. ~: ....,.-i,.,1'.w~~ lffamma!,i!e"1"(l'i'r•i8s/l~"ffr1"7~;,.;i;,: .. :,c,'k---cr"'-"~;;;,':;;,;,;,,E.;1.f¥,'.:'i'>.,.-;,, ·, IJSfgflfH~J ri!liliffi'f TOTAL-Flammable Liquids 1-C (LIQUIDS] AGGREGATE TOTAL Flammable Liquids 1-C [LIQUIDS]: 1.0567 Gins 1.0567 GALLONS LIQUIDS HAVING FIRE POINTS -1997 UBC TABLE 3-D/UFC TABLE 7902.5-A EXEMPT AMOUNTS PER CONTROL AREA: STORAGE & USE CLOSED -H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. USE OPEN & PRESSURIZED SYSTEMS >15 PSIG -H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: · 180 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 360 GALLONS USE CLOSED EXEMPT AMOUNT: 180 GALLONS USE OPEN EXEMPT AMOUNT: 40 GALLONS LIQUIDS WITHOUT FIRE POINTS-1997 UBC TABLE 30D/UFC TABLE 7902.5-A, 7901.1.1/Exceplion 9 EXEMPT AMOUNTS PER CONTROL AREA: STORAGE: UNLIMITED USE CLOSED EXEMPT AMOUNT: 180 GALLONS USE OPEN EXEMPT AMOUNT: 40 GALLONS MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1/EXCEPTION 3: . </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED GROUP M OCCUPANCY -MAXIMUM QUANTITIES PER CONTROL AREA• UFC TABLE 7902.5-B • COMBINATION 1-B, 1-C, II, Ill-A: CEILINGS </=18' HIGH -</=6' SHELF STORAGE, </=4.5' OTHER STORAGE: 7,500 GALLONS SPECIAL SPRINKLER SYSTEM PROTECTION: 15,000 GALLONS CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only -· no use conditions. .. ,-···· c; 1---.. ,_ r···· · ·t-,~_,,~.%'-·i:r'*', 12°:E·ief''ifj 0.0000 Gins :ii -'l:fm,J1;,l ~ ~tJ2~~1,.f;!1 ~ 0.0000 Gins J'"~·~ r,~, t1}Z-f~ittfu \:J-'t~i 0.0000 Gins 0.0000 ~ ~ Gins SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC.· 04/23/2001 -PAGE 4 1 .. L1111111 lllllil Laa1 W _.. _. m---f'TI ;-----< ---- r, .. f ___ ,n lllil r:n --.. HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-D -UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY -PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage 1!:I''-<",--,,.,mr· ·-,::e .. ,if~-) ,,, 'h)i;f'?"F's'"'7'=7,F,j"V9pv ~""";~k'.~(-<:tc ':!ir~ ~.:emm~~~i~)!~~;;,,.~~i~~~:;1}11:~~k-~:~~~tr.f~·~l7f~::;rMW;·~-~; fi!D"''W] ,, 11.P.,eii ~ ~ m~u~4~'1 Fwm~11 ~-», __ , ,:r,,P -~,--., TOTAL Flammable Solids [SOLIDS] AGGREGATE TOTAL Flammable Solids [SOLIDS]: 0.4420 0.4420 POUNDS Lbs 1997 UBC'TABLE 3-0/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA· H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT-NO CABINETS: 250 POUNDS STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 500 POUNDS 0.0000 USE CLOSED EXEMPT AMOUNT: NOT APPLICABLE -NO FIRE/EXPLOSION HAZARD POTENTIAL USE OPEN EXEMPT AMOUNT: NOT APPLICABLE-NO FIRE/EXPLOSION HAZARD POTENTIAL ~~JgJ.~~~~}~k~;~~~~;~:?,;!/;:Z~I~ij/~1~:;~H!~f~~~]!~ti~j TOTAL Oxidizers 1 [SOLIDS] AGGREGATE TOTAL Oxidizers 1 [SOLIDS): TOTAL Oxidizers 1 {LIQUIDS] AGGREGATE TOTAL Oxidizers 1 [LIQUIDS]: j!:sur-111 :~.,,,:-~~: 28.7300 -Lbs 28.7300 POUNDS 0.2641 Gins 0.2641 GAL!.-QNS 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA -H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: 8;000 POUNDS+ 800 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT-WITH CABINETS: 16,000 POUNDS+ 1,600 GALLONS USE CLOSED EXEMPT AMOUNT: 8,000 POUNDS+ 800 GALLONS USE OPEN EXEMPT AMOUNT: 2,000 POUNDS+ 200 GALLONS 0.0000 0.0000 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY-EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 36,000 POUNDS+ 3,600 GALLONS 1999 UFC SUPPLEMENT -RETAIN/WHOl£SALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: SAME AS 1997 UFC 1999 UFC SUPPLEMENT -S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 36,000 POUNDS+ 3,600 GALLONS CONTROL AREA 2/Room 140: 51 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only --no use conditions. Lbs. lliiJ . Lbs Gins 0.0000 l~':1'tire-•zr,I :>i::A~'l.,_,...,-':--;~o/',i,~: 0.0000 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 5 .. .. Lbs JL~_wtl Lbs Gins ~~~-~r~-,--,,----,---~~q-·snt-51-g __ www- HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-D -UFC/CFC TABLES 7902,5-A, 7903.2-B, 8001.15-A SUMMARY· PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw IV!aterial Storage ~f{g~t~~~f~~~1~f,rf{;~:~:~fajJ~~~~~~~1ff~f~~J!~~~ TOTAL Oxidizers 3 [SOLIDS) AGGREGATE TOTAL Oxidizers 3 [SOLIDS): f mt.<ft~~~I 1.6575 1.6575 POUNDS Lbs 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA-H-2 OCCUPANCY REQUIRED ONL V FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: 20 POUNDS+ 2 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT· WITH CABINETS: 40 POUNDS+ 4 GALLONS USE CLOSED EXEMPT AMOUNT: 4 POUNDS+ 0.40 GALLON USE OPEN EXEMPT AMOUNT: 4 POUNDS + 0.40 GALLON ~ . 0.0000 Lbs 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY· EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 2,250 POUNDS+ 225 GALLONS 1999 UFC SUPPLEMENT· RETAILNVHOLESALE STORG/DISPLAY • EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 2,300 POUNDS+ 230 GALLONS 1997 UBC TABLE 3-G/UFC TABLE 8003.1-B • MAXIMUM AMOUNT PER BUILDING WITHOUT DETACHED STORAGE: 1,200 TONS 1999 UFC SUPPLEMENT· S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 2,300 POUNDS+ 230 GALLONS UifC.ffifil~DAa"~tl~es'-sf?,;lr!'_E'!,~;;;,~;,S"¾-,\ tz•t+~~-?,l.':,u.;;e,'1;'1:-";.l :,, , ,tr:,, ',' -~ ... , ~?~n-cr, ,,!:,,,~;,;-/',,~411.:;'<i ,M,, <t&~iC-a.vi5-~~t"0~ "¼'./ ... i..~.lf.·,,r¥""¥>-~,t,Ri,tK"~ TOTAL Unstable Reactives 1 [LIQUIDS) AGGREGATE TOTAL Unstable Reactives 1 [LIQUIDS): ft'\Stb'>¾rl'A'.11 @nil t,l>,,;,",:;~ ..... SI~,& ~ ... :.-~~~ , , I 0.0066 Gins 0,0066 GALLONS 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA· H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: UNLIMITED STORAGE/AGGREGATE EXEMPT AMOUNT· WITH CABINETS: UNLIMITED USE CLOSED EXEMPT AMOUNT: UNLIMITED USE OPEN EXEMPT AMOUNT: UNLIMITED · NOTE: PUBLICATION ERROR -ERRATA TO UBC & UFC TO CORRECT GASES TO UNLIMITED. CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only -· no use conditions. r"''.HPAS111:~1 &Y:;.1lf§lf ?.?Ly ,,p;-;;,.'-'_:, -, ><z ~ ~ 0.0000 Gins t~~~~~ 0.0000 C~U91PI ',f, 7&-, :;; ,__t;.f 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 6 lffl1 - Lbs 1Bm[i1 Gins Lall tlllll .. ..... , ......... .. .. ~ ---~i-······ ... 1 ... -·-· ~! _., .... -lllir 'fMt t ---··1 -... -. --' .. HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-D-UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY -PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 2-Room 140/Raw Material Storage !J~~~l\~!i~J~ic.2),{i:,3:YJit1;;;;,½;~}1~~,J!¼~i TOTAL Unstable Reactives 2 [SOLIDS) AGGREGATE TOTAL Unstable Reactives 2 [SOLIDS]: :i1ls!~i.9!1 0.4420 0.4420 POUNDS 0.4755 1:9-.ttJ.t!'.I Lbs Gins TOTAL Unstable Reactives 2 [LIQUIDS) AGGREGATE TOTAL Unstable Reactives 2 [LIQUIDS): 0.4755 GALLONS 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA· H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT-NO CABINETS: 100 POUNDS+ 10 GALLONS & 1,500 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 200 POUNDS + 20 GALLONS & 3,000 CUBIC FEET USE CLOSED EXEMPT AMOUNT: 100 POUNDS+ 10 GALLONS & 1,500 CUBIC FEET USE OPEN EXEMPT AMOUNT: 20 POUNDS + 2 GALLONS 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY. EXEMPT AMOUNTS PER MJS OCCUPANCY CONTROL AREA: 900 POUNDS+ 90 GALLONS i;,~J~ 0.0000 0.0000 1999 UFC SUPPLEMENT-RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 1,300 POUNDS+ 230 GALLONS 1997 UBC TABLE 3-G/UFC TABLE 8003.1-B • MAXIMUM AMOUNT PER BUILDING WITHOUT DETACHED STORAGE: GASES-10,000 CUBIC FEET ' LIQUIDS & SOLIDS -25 TONS 1999 UFC SUPPLEMENT-GROUPS OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 2,300 POUNDS+ 230 GALLONS 1-ir·i:.1,1 r ;o"' '"'•ftfi""''"''q*""''7<>,'fr'••.''Y'f:'' .. ,"i/,!,1if,'f,K,',7)~:-1r' '""'"' ~l',!~~-tJ4.tlJ!~~~~~yi.i~~)fC&;,:iJrt.f:t;;f:¢A:~'M},£ff~1f~'{t~r.Z1t1:ii~~;;;~~~; j;~jtiflmrl 'J.1/m ;,-,4>-,., N -~, [Mm~;) 'TOTAL Unstable Reactives 3 [SOLIDS) AGGREGATE TOTAL Unstable Reactives 3 [SOLIDS): 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA. NONDETONATABLE -H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. DETONATABLE -H-1 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. 1.1603 1.1603 POUNDS STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: 10 POUNDS+ 1 GALLON & 100 CUBIC FEET Lbs STORAGE/AGGREGATE EXEMPT AMOUNT· WITH CABINETS: 20 POUNDS+ 2 GALLONS & 200 CUBIC FEET USE CLOSED EXEMPT AMOUNT: 2 POUNDS+ 0.20 GALLON & 20 CUBIC FEET USE OPEN EXEMPT AMOUNT: 2 POUNDS + 0.20 GALLON · r: ~: !le'-"·'~ ~t.;.i~;,_ ~l e!f~·! 0.0000 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MJS OCCUPANCY CONTROL AREA: 1,125 POUNDS+ 112.5 GALLONS 1997 UBC TABLE 3-G/UFC 80.03.1-B -MAXIMUM AMOUNTS PER BUILDING WITHOUT DETACHED STORAGE: GASES· 2,000 CUBIC FEET LIQUIDS & SOLIDS -1 TON 1999 UFC SUPPLEMENT. S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 1,100 POUNDS+ 110 GALLONS CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only -no use conditions. ~ ' r''k~Wd'-h~~j ~-,..-:~-i;'.,.(<-fn Lbs 0.0000 Gins 0.0000 ~ JJEY~li· Lbs 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 7 - Lbs Gins ~ ~ Lbs - ~ ;-]illliilia ~ ·-· "' Uall .. --r···~ .. ,--·-·- HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS r,-,,. ::-~ --..· ., -.. .. UBC/CBC TABLE 3-D-UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY-PHYSICAL HAZARD MATERIALS lnvltrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 2 -Room 140/Raw Material Storage :w.~~tfttJ§:~v~~a~tflt~~~r~tt~:;~ffi::Jfii~~~¾~~~f~~~: TOTAL Water Reactives 1 [SOLIDS] AGGREGATE TOTAL Water Reactives 1 [SOLIDS]: TOTAL Water Reactives 1 [LIQUIDS] AGGREGATE TOTAL Water Reactives 1 · [LIQUIDS): ~~~if§~ 19.2270 Lbs 19.2270 POUNDS 5.4227 Gins 5.4227 GALLONS 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA· H OCCUPANCY NOT REQUIRED IN SPRINKLERED BUILDING. STORAGE/AGGREGATE EXEMPT AMOUNT-NO CABINETS: UNLIMITED STORAGE/AGGREGATE EXEMPT AMOUNT-WITH CABINETS: UNLIMITED USE CLOSED EXEMPT AMOUNT: UNLIMITED USE OPEN EXEMPT AMOUNT: UNLIMITED CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only -no use conditions. '{. _,, r r~--, ----, ~ ....... '~ t?i~gJ;fiZ ~ . ~iP!}A~::- 0.0000 Lbs 0.0000 0.0000 Gins 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 8 , ..... s , ... , .. .. ~ ' Lbs Gins ·--, . ..-:-·-··--.. ,,--.. !-aalllllll C..... ~ !:. L ·r r · ~ -·-···-, ~r,---, ;:· .. ·-; ·f-a r· -71~11 r· ····--:-p<··--1 'Ill ---:·· a HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS USC/CBC TABLE 3-D-UFC/CFC TABLES 7902,5-A, 7903.2-8, 8001.15-A SUMMARY-PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage Wt>~r,ir>e'-"·a" ctrve~ ... .,Yi(:.,:,,y.fr:m4S!M:f,' ,,i·,'j/'{:faJit:'it;:,,,-r;·; .... "'~1*.::J;cttii;;\~' ,i/A·~-~~ .. }~~-~,:,,~,,frl'A.,,~::::;r2. .. :<:I6:-.~Jj1.~:£D1:~~/):-:?-Jlli:~~;.;;.~:u?:-~~~:d.t"1>t~1 ~.,trjl}.!1 l1ml~I 11e~m1ffll ~ ~t::-i= ~Wn?,),l, TOTAL Water Reactives 2 [SOLIDS] AGGREGATE TOTAL Water Reactives 2 (SOLIDS): TOTAL Water Reactives 2 [LIQUIDS] AGGREGATE TOTAL Water Reactives 2 [LIQUIDS]: 2.0443 2.0443 POUNDS 1.0567 1.0567 gALLONS Lbs Gins 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA· H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: -100 POUNDS+ 10 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT· WITH CABINETS: 200 POUNDS+ 20 GALLONS USE CLOSED EXEMPT AMOUNT: 100 POUNDS+ 10 GALLONS USE OPEN EXEMPT AMOUNT: 20 POUNDS+ 2 GALLONS 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY· EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 900 POUNDS+ 90 GALLONS 1999 UFC SUPPLEMENT-RETAIL/WHOLE STORAGE/DISPLAY· EXEMPT AMOUNTS PER M/S OCCUPANCY CONTROL AREA: 2,300 POUNDS+ 230 GALLONS 1997 UBC TABLE 3-G/UFC TALBE 8003.1-B • MAXIMUM AMOUNTS PER BUILDING WITHOUT DETACHED STORAGE: GASES -10,000 CUBIC FEET ' . SOLIDS & LIQUIDS -25 TONS 1999 UFC SUPPLEMENT -S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 1,300 POUNDS+ 230 GALLONS CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only -no use conditions. 0.0000 Lbs 0.0000 Gins r-~~·1 ~~-... ,· ~~ ~..... ,,;;,,; ,,.., 0.0000 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RA TIAN ASSOCIATES INC. • 04/23/2001 -PAGE 9 --·· g .. ~ , Lbs Gins ·-,·-:..:. ~ ~-.. t-.... ----.. l_l-.1 --_. rn·1 HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E -UFC/CFC TABLE 8001.15-B SUMMARY -HEALTH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage Solids Material Lbs Carcinogens 3.9117 Corrosives 270.7800 Highly Toxics 1.1603 Irritants 5492.7778 - Irritants-Consumer Products 0.2210 Other Health Hazards 466.1941 Sensitizers 7.0720 Toxics 218.3254 STORAGE Liquid Gins 14.4917 86.1411 187.9524 149.7367 30.2731 21.1740 Gas Cf Solid Lbs USE CLOSED Liquid Gins Gas Cf 1997/1998 CODES -CONTROL AREA 2: 51 OCCUPANCY CONDITIONS BASED ON THE STORAGE OF HEALTH HAZARD MATERIALS. Storage only -no use-conditions. Building is protected throughout by an automatic fire sprinkler system. Solid Lbs ::--·-.. [- USE OPEN Liquid Gins SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RA TT AN ASSOCIATES INC. -04/23/2001 -PAGE 10 ;,-· ·-· - Gas Cf .... ·, ,.__. r .. .._ ~~ ;_11111 ,,;' .... , ... {""-·"; E '; ---~-, :r·-·· .. r·--z t' ., ... -·1 rr"Tt ,_ '.:.-,~,,-, ?·-rn ' r,~-, ·:,--,-. r·····-·-- HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E-UFC/CFC TABLE 8001.15-B SUMMARY -HEALTH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage ,~m ... ,t ~ ~t,: , n19~~ !'.~.tu!tM J1r->i~ llflte!] ...., -~· · ·-· !IL . .:-: TOTAL Carcinogens [SOLIDS) AGGREGATE TOTAL Carcinogens [SOLIDS]: TOTAL Carcinogens [LIQUIDS) AGGREGATE TOTAL Carcinogens [LIQUIDS): CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE 8001.15-B: 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS: TOTAL Corrosives [SOLIDS] AGGREGATE TOTAL Corrosives [SOLIDS): TOTAL Corrosives [LIQUIDS] AGGREGATE TOTAL Corrosives [LIQUIDS): 3.9117 Lbs 3.9117 POUNDS 14.4917 Gins 14.4917 GALLONS UNLIMITED UNLIMITED -WITH SPECIAL CONTROLS l~@DJil~I ,~~!!i11 270.7800 Lbs 270.7800 · POUNDS 86.1411 Gins 86.1411 GALl.Q_N$ 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS PER CONTROL AREA -H-7 OCCUPANCY REQURIED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT-NO CABINETS: 10,000 POUNDS+ 1,000 GALLONS & 1,620 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 20,000 POUNDS+ 2,000 GALLONS & 3,240 CUBIC FEET USE CLOSED EXEMPT AMOUNT: 10,000 POUNDS+ 1,000 GALLONS & 1,620 CUBIC FEET USE OPEN EXEMPT AMOUNT: 2,000 POUNDS+ 200 GALLONS 0.0000 0.0000 0.0000 0.0000 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 19,500 POUNDS + 1,950 GALLONS 1999 UFC SUPPLEMENT-RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 20,000 POUNDS+ 2,000 GALLONS 1999 UFC CUPPLEMENT -S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 20,000 POUNDS+ 2,000 GALLONS CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only -no use conditions. Lbs Gins ~ ' Lbs Gins li$I!Wi~I 0.0000 0.0000 lf~lU'l"Jtl • ,cs,wij_4 0.0000 0.0000 SUMMARY-HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS-ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 11 -... ~ " Lbs Gins ~ ;; Lbs Gins ;__. r . .-... l..-.~ ··-(: r ..... ~ ':aliaia ~ if,. ..• .. f ----1 m·-·• t4liiiillillla ~ ·r ·1 --.. " -,. ____ _ r.._. ~ HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E-UFC/CFC TABLE 8001.15-B SUMMARY-HEALTH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage TOTAL Highly Toxics [SOLIDS] AGGREGATE TOTAL Highly Toxics [SOLIDS]: r~a .. ~.ib¼I ;~,J~J-r!.~~; ,½ 1.1603 1.1603 POUNDS ~ ~ Lbs 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS PER CONTROL AREA· H-7 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: 20 POUNDS+ 2 GALLONS & 0 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 40 POUNDS+ 4 GALLONS & 40 CUBIC FEET . w.r,-fi~~-; 6;\y:,,~~;~'f 0.0000 ~ ~ Lbs USE CLOSED EXEMPT AMOUNT: 20 POUNDS+ 2 GALLONS & 40 CUBIC FEET [CAB/EXHAUSTED ENCL REQD) USE OPEN EXEMPT AMOUNT: 6 POUNDS+ 0.6 GALLON 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 39 POUNDS+ 3.9 GALLONS 1999 UFC SUPPLEMENT· RETAIL/WHOLESALE STORAGE/DISPLAY· EXEMPT AMUNTS PER MIS OCCUPANCY CONTROL AREA: 40 POUNDS+ 4 GALLONS 1999 UFC SUPPLEMENT-$ OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 40 POUNDS+ 4 GALLONS ... 0.0000 twtiill~~P4~~~~~~r~jteff;J~(fif~4i~4iJl,~-~:-~1:,~~~~ J.£<:im.."'=€fJ t~(ffJ.lfs! ~~:-!t"Dw~ m. ~ , ... ~; ~ . ,;:;t,f'.:,1'!,,:-,:,,)1:f:-,t r·'7'l\lllf~'·\u~ TOTAL Irritants [SOLIDS] AGGREGATE TOTAL Irritants [SOLIDS]: TOTAL Irritants [LIQUIDS] AGGREGATE TOTAL Irritants {LIQUIDS): CONSUMER PRODUCTS-1997 UBC TABLE 3-E/UFC TABLE 8001.15-B: 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS: STORAGE/AGGREGATE EXEMPT AMOUNT: USE CLOSED EXEMPT AMOUNT: USE OPEN EXEMPT AMOUNT: CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only -no use conditions. UNLIMITED UNLIMITED UNLIMITED 5492.7778 Lbs 5492.7778 POUNDS 187.9524 Gins 187.9524 GALLONS UNLIMITED • WITH SPECIAL CONTROLS 0.0000 Lbs 0.0000 0.0000 Gins 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 12 ----· ?' ,---' Lbs ~ . Lbs Gins tai i:1111111 .. ~-._ f-----f, -·--:a ._ JrT1 .. , ____ _ -. FfT -llll -.... HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E-UFC/CFC TABLE 8001.15-B SUMMARY -HEALTH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage ®~~~oo.f~rt-~~q,1llltlj'.!f~ft4-~?Jil½iiftf~gr~~f.~:i¥) l0$t4fj§eij l~YW!iil x. .. -~ . .,..4h , ~lo' TOTAL Irritants-Consumer Products [SOLIDS] 0.2210 Lbs AGGREGATE TOTAL Irritants-Consumer Products [SOLIDS): 0.2210 POUNDS CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE 8001.15-B FOOTNOTE 7 EXEMPT AMOUNTS: UNLIMITED ;@Mt~~ffli#~~t~~~~l:~:J:l&t~~?~~~~?if~tftl~\~£: TOTAL Other Health Hazards [SOLIDS] AGGREGATE TOTAL Other Health Hazards [SOLIDS): TOTAL Other Health Hazards [LIQUIDS) AGGREGATE TOTAL Other Health Hazards (LIQUIDS]: CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE 8001.15-B: 1997 UBC TABLE 3-E/UFC TABLE 8001.15-8 EXEMPT AMOUNTS: STORAGE/AGGREGATE EXEMPT AMOUNT: USE CLOSED EXEMPT AMOUNT: USE OPEN EXEMPT AMOUNT: CONTRc;:>L AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only -no use conditions .. J}~la ~~r.. ' { i1Pll1'1 466.1941 Lbs 466.1941 POUNDS 149.7367 Gins 149.7367 GALLONS UNLIMITED UNLIMITED UNLIMITED UNLIMITED -WITH SPECIAL CONTROLS ~ue-,~r-~1 f.-OfiltsJ : ~,'M ic'..-f,f,M~ ~jff', ,,,-J,,r.;~ ll~~}tii) 0.0000 Lbs 0.0000 ,~,J?(jjf!!f-A) ~.~=~· ;::...:--mBl i}1,.0Q.J½ h·= ,;z 0.00OQ Lbs 0.0000 0.0000 Gins 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 13 ,.---r-' fflmf?j Lbs ~ ' Lbs Gins - Lllllit~ ~-~;--~ .. .. f,i-----. ~ -f-iliiiiiiill. ,........ HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS qr. --, -' r-·· ., '- UBC/CBC TABLE 3-E -UFC/CFC TABLE 8001.15-B SUMMARY -HEAL TH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2-Room 140/Raw Material Storage ~-tg~1ff*~iir.~~~~~~u~,~Y~~~~~;i; TOTAL Sensitizers [SOLIDS] AGGREGATE TOTAL Sensitizers [SOLIDS]: TOTAL Sensitizers (LIQUIDS] AGGREGATE TOTAL Sensitizers (LIQUIDS): CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE 8001.15-B: 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS: STORAGE/AG~REGATE EXEMPT AMOUNT: UNLIMITED UNLIMITED .. r··Ts - ;,..,w:~lil p::s1rra,q1 ~ - 7.0720 Lbs 7.0720 POUNDS 30.2731 Gins 30.2731 GALLONS USE CLOSED EXEMPT AMOUNT: UNLIMITED . USE OPEN EXEMPT AMOUNT: !9~t[~~~1?:;~~,~;;j_0,::~~E~#ff~4~-~;~S~!l¼:f$SfZ'-t~~~~ TOTAL Toxics [SOLIDS] AGGREGATE TOTAL Toxics [SOLIDS]: TOTAL Toxics {LIQUIDS) AGGREGATE TOTAL Toxics [LIQUIDS]: UNLIMITED -WITH SPECIAL CONTROLS r~me~I ~;;~~, ,M ~ ~ 218.3254 Lbs 218.3254 POUNDS 21.1740 Gins 21.1740 GALLONS 1997 USC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS PER CONTROL AREA -H-7 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 1,000 POUNDS+ 100 GALLONS & 1,620 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 2,000 POUNDS+ 200 GALLONS & 3,240 CUBIC FEET USE CLOSED EXEMPT AMOUNT: 1,000 POUNDS+ 100 GALLONS & 1,620CUBIC FEET USE OPEN EXEMPT AMOUNT: 250 POUNDS+ 25 GALLONS '---·-i '.."---~ 5-..... ~ 191 i~[~~ -~~~~;;: ~ J\~~:tl IT"O.§f''~ n:qurl 1r,{t1~~1 0.0000 Lbs 0.0000 0.0000 Gins 0.0000 t~i?tJQ·":,#1 i-;,;~'""1.frra f®lY~~ 0.0000 Lbs 0.0000 0.0000 Gins 0.0000 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY • EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 1,950 POUNDS + 195 GALLONS + 3,160 CF 1999 UFC SUPPLEMENT -RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 2,000 POUNDS+ 200 GALLONS 1999 UFC SUPPLEMENT -S OCCUPANCY STORAGE WITH UFC 8001.14 STORGE CONDITIONS: 2,000 POUNDS+ 200 GALLONS. CONTROL AREA 2/Room 140: S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Storage only --no use conditions. SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04i23/2001 -PAGE 14 _,_ ·-~ -f._ mMl , Lbs ·Gins llmll ' Lbs Gins 11 IJ 11 IJ 11 I I I I I I I I ;I ... \' ' \ I I I :I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net ~ ~ ··--. -~----~ , ....... ~ r ·-r I ''iiiiliiilll t~ ........... f .. ,,. . " -:<liiiilllll ~ r_·· ···-; o-·--·l ·-~ nrr.1 ~---~ ~ ·-----c., ru i-, ..... .. r··r-- 04-23-01 Page1 lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage: Hazardous Materials Inventory 64-19-7 L >80 Acetic Acid (Glacial) [BP: 118.1o; FP: CL2,CR 17.4618 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material 104-109oF] [LEL: 5.4%; UEL: 15%] (pH: Storage [New) 2.4) [LD50-0ral: 3,310 mg/kg; LD50-Skin: 1,060 mg/kg) [HR: H3 F2 COR) 2 108-24-7 L 100 Acetic Anhydride [Acetic Oxide) [Acetyl CL2,CR, WR1 5.0000 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material Oxide) [MP: -730; BP: 1380; FP: 130oF) Storage [New) [HR: H3 F2 R1 COR) 3 75-05-8 L >/=50 Acetonitrile [Amidite Diluent] [FP: 42oF; FL1B, IR 3.1791 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material BP: 81oF) [lEL: 3; UEL: 16) [HR: H2 F3) Storage [New) 4 9031-72-5 s 100 Alcohol Dehydrqgenase [HR: H1) SN 4.0000 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Storage [New) 5 1336-21-6 L >50 Ammonium Hydroxide [Aqua Ammonia) CR,TX 13.0237 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material [NH40H) [pH >13) [Base) [LD50-0ral: Storage [New] 350 mg/kg) [HR: H3 CORJ -·-··-- 6 7727-54-0 s 100 Ammonium Persulfate [Ammonium CR,OX1,SN 6.6300 Lbs 0.0000 Lbs 0.0000 Lbs y 140/Raw Material Peroxydisulfate] [RTECS# SE0350000J Storage [New) [HR: H3 COR OX) 7 7783-20-2· L </=90 Ammonium Sulfate [HR: OJ NH 46.5205 Gins 0.0000 GJns 0.0000 Gins 140/Raw Material Storage [New] 8 74-79-3 s 100 Arginine (L-} [MP: 236oCJ [RTECS# NH 100.0000 Lbs Lbs Lbs 140/Raw Material CF1934200) [HR: OJ Storage [New] 9 150-25-4 s 100 Bicine [N,N-Bis(2-Hydroxyethyl)Glycine] CR 10.3870 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [Protein Assay Kit-Bicinchonic Acid] Storage [New) [HR:H3COR] 10 150-25-4 s 100 Bicine [N,N-Bis(2-Hydroxyethyl}Glycine) CR 198.9000 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [Protein Assay Kit -Bicinchonic Acid) Storage [New) [HR:H3COR) 11 6976-37-0 s 100 Bis(Hydroxymethyl)-2,2' ,2"-IR,OHH 442.0000 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Nitrilotriethanol (2,2-) [Bis-Tris] [Bis(2-Storage [New] Hydroxyethyf) lminotris (Hydroxymethyl) Methane) [HR: H2) 12 10043-35-3 s 100 Boric Acid [RTECS# ED4550000] [HR: IR 47.5150 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material H1) Storage [New] -------···· LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLY-Combustible Liquid Vapor. FLY-Flammable Liquid Vapor. Storage only -no use conditions. Building is protected throughout by an automatic fire sprinkler system. ;:--L1111 "... .-··: --~·: c·--,-: ~rr: r-~~-T .rn---~_r,,.~ r-·--,,,-: r-'Tl 1111,: r----l rrr~,1 'fma r····"J ,y·---··1 ~ -- 04-23-01 Page2 lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage: Hazardous Materials Inventory i~fff1~1i{2i::'.sif~~m:.irmr,,a1lz;5-i~rrr~t~i~!i'.' ::J.-i;;·: ,l!~., ·~~h~~w~W;~{~::~i:e5~~~~4:A ~.:'°~~1~ffl .:¼-PAJ.$~f~f!E0~5£1!!l1:tt~J'¥ 5t~1-9~ t 13 71-36-3 L 100 Bulanol (1-) (Butyl Alcohol] [MPA 1075] FL1C, IR ' 1.0567 Gins 0.0000 · Gins 0.0000 Gins y 140/Raw Material (MPA 1075) (FP: 95oF; BP: 244oF) [SG: Storage (New) 0.81; VD: 2.6; VP: 7] [LFL: 1.4; UFL: 11.2](FVperGlnd: 2410 cO [HR: H2 F3] 14 75-60-5 s 100 Cacodylic Acid [Hydroxydimethylarsine CA, IR, OHH, P65 0.0442 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Oxide] (Dimethylhydroxyarsine Oxide] Storage (New] (LD50-0: 644 mg/kg] (RTECS# CH7525000) [HR: H2] 15 10035-04-8 s 100 Calcium Chloride [Calcium Chloride IR 2.2100 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Oihydrate] [RTECS# EV9800000] [HR: • Storage [New] H2] ------· 16 10101-41-4 s 100 Calcium(!!) Sulfate Dihydrate (Gypsum] IR-CP 0.2210 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material (Plaster of Paris] [Kellys Gypsum] Storage (New] (Recycle~ Earth Sheetrock) [Agri Gypsum) (Ben Franklin Gypsum) [Soil Buster Gypsun] [HR: H1] 17 616-17-7 L 100 Cap B Solution [Cap B Solution Mix] [1-CR,FL1B 0.1585 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material Methylimidazole/616-47-7; Storage [New] Tetrahydrofuran/109-99-9; Pyridlne/110- 86-1) [FP: 1oF; BP: 133oF] [LEL: 2.6%; UEL: 12.8%] [HR: H3 F3 COR] 16 65072-00-6 s 100 Casein [Enzymatic Hydrolysate Casein) NH 22.1000 Lbs 0.0000 Lbs 0,0000 Lbs 140/Raw Material [Z-Amine A Milk Protein] [HR: OJ Storage [New] 19 7647-17-6 s 100 Cesium Chloride [MP: 6450) [RTECS# IR 0.2210 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material FK9625000) (HR: H2) Storage (New] 20 57-15-6 s 100 Chlorobutanol (Acetone Chloroform] TX 10.0000 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [1, 1, 1-Trichloro-2-Methyl-2-Propanol] Storage [New] [LD50-0: 213 mg/kg] [RTECS# VC0175000] [HR: H3] ------ 21 67-66-3 L 100 Chloroform [Trichloromethane] [LD50-CA, IR, OHH, P65, 0.1321 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material Oral: 906 mg/kg] [MP: -630; BP: 61oC; RMP-T1, RMP-T3 Storage (New] FP: None] [HR: H3] 22 7758-99-6 s 100 Copper(II) Sulfate Penlahydrale [Cupric 'IR,TX 0.4862 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Sulfate Pentahydrale] [LD50-0ral: 300 Storage (New] mg/kg] [RTECS# GL8900000] [HR: H2] -·--·----·-·· LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Llquic:f Vapor. FLY-Flammable Liquid Vapor. Storage only -no use conditions. Building is protected throughout by an automatic fire sprinkler system. :.am llll .. ~ ~ ?--~ ~ -.. (,-~ ~--~ --P--cf--::: --~---" --·- r~ ',liililliill ~ T,lllliillilla ~ Tl"' 04-23-01 Page3 lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2-Room 140/Raw Material Storage: Hazardous Materials Inventory ~~-,.,ti J"'4/'Y' ~-c<>.,,.,,,.z:t~f''<>""~ "'"~~..f'!:!~<.<~-,...,,...,.,...,.,,;,,t):_¥r--""--,..-ct hg:~"'-'f{t;f'f,'-~-.4-Jsr,:-1 ,~ 1lfmf ~ffl,~ffini(il.-'\'.,Yi,'>,• j;?,~k '1"'~,,,t·,s¾i!'.iJftiilffa~i'lt ru~i;(;,'l§q~sr&riis (;\~r},.&.t:/,,.tltf-,y~,;ti~;l}<ii'jJt}f~~:,-~~:~~~~4Jl{~J½r~Z~~~i-,',µ.l'it&J~i~-~~::;-f:e 23 57 407-08-6* L 100 DEAE Sepharose [Dlethylaminoelhyl FL 1B, IR, OHH 1.5850 Gins 0.0000· Gins 0.0000 -Gins y 140/Raw Material Sepharose) [Suspension in 20% Ethanol) Storage [New] [HR: H2F1) 24 2001-000-19 L 100 Deblock Solution [50% Methylene CA, CR, OHH, TX, 1.1888 . Gins 0.0000 Gins 0.0000 Gins 140/Raw Material Chloridell5-09-2; 50% Dichloroacetic P65 Storage [New] Acidll9-43-6] [LC50: >5,000 ppm; LD50- S: 1,111 mg/kg] [FP: None] [HR: H3 COR) ------ 25 79-43-6 L 100 Dichloroacetic Acid [BP: 1940; FP: None] CA, CR, OHH, TX, 5.0000 Gins 0.0000 Gins. 0.0000 Gins 140/Raw Material (LD50-0: 2820 mg/kg; LD50-S: 510 P65 Storage [New] mg/kg) [HR: H3 COR] 26 75-09-2 L >/=70 Oichloromethane (Methylene Chloride) CA, CR, OHH, P65 3.1701 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material [Methane Dichloride) [Freon 30) [BP: Storage [New] 104oF; FP: None] [HR: H3 COR] 27 1609-47-8 L 100 Dielhylpyrocarbonate (Diethyl CL3A,IR 0.3170 Gins . 0.0000 Gins 0.0000 Gins y 140/Raw Material Oxydiformate] (Diethyl Pyrocarbonate] Storage [New] [DEPC] [DEP] [RTECS# LQ9350000] [BP: 93o/18mm; FP: 157oF] [LD50-0: 850 mg/kg] [HR: H2 F2] 28 67-68-5 L 100 Dimethyl Sulfoxide [DMSO] (Methyl CL3B,IR,SN 0.0240 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material Sulfoxide] [RlboGreen-Component B Storage (New) [PicoGreen-Compon~nt A] [PicoGreen] [FP: 203oF; BP: 3720F) [LD50-0: 14,500 mg/kg) [RTECS# PV6210000] [HR: H2 F1] 29 68-12-2 L 100 Dimethylfonnamide (N,N-) [DMF) [pH: 8) CA,CL2,IR 4.1554 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material [FP: 126oF; BP: 153oF] [RTECS# Storage [New] LQ2100000) [HR: H3 F2) 30 27565-41-9 s 100 Dithlothreitol [Cleland's Reagent] [OTT) IR,OHH 1.3260 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [dl-DTT] [Threo-1,4-Dimercapto-2,3-Storage [New) Butanediol] [DTT] (Luciferase Assay Substrate] [HR: H2] -- 31 60-00-4 s 100 EDTA (Ethylenedlamlnetetraacetlc Acid] IR 27.4040 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [EDTA Free Acid] [ACS Reagent] [MP: Storage [New) 2500] [RTECS# AH4025000) [HR: H1] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustib!e Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only -no use conditions. Building Is protected throughout by an automatic fire sprinkler system. :--r,;_ ~ Jal ,"-~ f .... ~ -" [,lillllliil ~ ~ ~ I .. u-. ::.-~ --l ~ ,;----~ .. i ..... ~ .. l ',, 04-23-01 Page4 lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 2-Room 140/Raw Material_Storage: Hazardous Materials Inventory ~:r;~i~j:<--t:~*'~fl}~::£~~~,,.-~:;4J,', ;_, (= ~i<trfl!t fl-;;;, 'Qt~--:tf ""t*'~:f.,,i ... "' "*i-,!~-· ·r , "h)i,k) $' .. -:,•; ¼-2 '·t ry/4"'-~-~;' '5., 1i1'h~ ,!!$.t,i~--~t, ': ,>,)\" ,, ••• , ~""" ~!{;'fo"if~iffl~1,rl">~ ~;.~-,, ' --"''")jjffi'f''r ff'V""'-'"'Ymljf"'r "'l!iffl'' b'z'fi0'!'f,!lt~';/"""',s'i),B'ib\''~fr~1rar~[j ~~llt~ii/Jli~t:'.Y.Alf.ltta:lfl,s1~ifi1~!£&::.vi ~1,;,,J~ffl1$Jc.fflJt.,,;,::~ 1 -,t~2~4;.>;Z\~JI~11ilf::s:\~~f-;'l~'-G$i0v.1 32 64-17-5 , L >/=70 Ethanol [Ethyl Alcohol) (Reagent Alcohol) FL 18, IR, OHH 19.9979 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material (Molasses Alcohol] (Aromatic Elixir) Storage (New) (ETOH] [Polyamide Rinse] (FP:55.6oF; BP: 78.32oC) [LEL: 3.3%; UEL: 19%] [FV per Gin: 1630) [HR: H3 F3) 33 64-17-5 L >/=70 Ethanol [Ethyl Alcohol] [Reagent Alcohol) FL1B,IR,OHH 7.9252 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material (Molasses Alcohol) [Aromatic EUxir] Storage [New) [ETOH] [Polyamide Rinse) [FP:55.6oF; BP: 78.32oC) (LEL: 3.3%; UEL: 19%) [FV per Gin: 1630) [HR: H3 F3) 34 64-17-5 L >/=70 Ethanol [Ethyl Alcoholl[ReagentAlcohol) FL1B, IR, OHH 79.2519 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material [Molasses Alcohol) [Aromatic Elixir) Storage [New) [ETOHJ [Polyamide Rinse] [FP:55.6oF; BP: 78.32oC] (LEL: 3.3%; UEL: 19%) [FV per Gin: 1630) [HR: H3 F3] 35 2002-24-6 s 100 Ethanolamine Hydrochloride (2-IR,OHH 1.0000 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Aminoethanol] [MP: 84oC) (RTECS# Storage [New] KJ6370000) [HR: H2] 36 107-21-1 L 100 Ethylene Glycol [1,2-Ethanediol] [EG] CL3B, IR, OHH 0.0774 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material [MACuDizer 9221-SJ [MacDermid 19227] Storage (New] [Dowtherm 4000] [Red Devil Onetime Spackllng] [FP: 232oF] [HR: H2 F1] 37 26873-S5-8 s 100 Ficoll 400 [Nonionic Synthetic Polymer of NH 0.0707 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Sucrose) (HR: OJ Storage [New) --- 38 26873-85-8 s 100 Ficoll 400 [Nonionic Synthetic Polymer of NH 0.8840 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Sucrose) [HR: OJ Storage [New] - 39 50-00-0* L 10-40 Formaldehyde [Formalin] [Cuposit Y) (10-CA, CL3B, IR, 0.7925 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material 40% Solution in Water] [Cuposit Y) OHH, TX, PSM, Storage (New] [Formalex] [pH: 6-6.5] [BP: 212oF; FP: P65, RMP-T1, >200oF) [LD50-0: 1250 mg/kg; LD50-S: RMP-T3 675 mg/kg] (HR: H3] 40 75-12-7 L 100 Formamide (BP: 210oC; FP: 310oF] CL38, IR, OHH 0.6851 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material [RTECS# LQ0525000) [HR: H2 F1] Storage [N~w] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only -no use conditions. Building is protected throughout by an automatic fire sprinkler system. t:-.. ~ (,..-. ~ .. tai [,;-~ !silillilill ~ ----t~ .. _-·-J -~[[] r··-·y -srr1 eilliiila ~---::--·---~-"t ~ C• -...----·-· ;;'" . -·--- 04-23-01 Page 5 lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 2 -Room 140/Raw Material Storage: Hazardous Materials Inventory /~::Zavl."~, ,, ~·-,t~.'ttlf0~,glitf.;;:0;~t"1"1:'·tt;;;!~~,i~;?,;;ff,;,::..~s~,.:,.'!~.@t'<f~n;b;;i;-.,;,;,'~C::'i'.w.~;;.r '•'t ::.,m_,,,,Un-1\ ,~,V.t-Kt:1;:;~c.:,t~·~,.-:;;,,,,';!;.,;tzJ2,'i'i:,,'Bti;J "''"ii" fi!::Py'1WM~~:,'k;;1%-1'if>.K?-!Ji~q,:ci;t,;f'~,t~---:P:::::ff':-rl-F!Ji't,(;~::J.i •B~,f,,;!_1-'l;f>~vy{Y~'M~ta.tet,;,~Quc.,~,~M~t~tiil"~L ~ x-~~.'rt~'-~-~~ , Q'-:,.ft,:-'1J:,~ t_:f]c:Uc2[<l~~,as~':;t:J''f/v -·t~Stor::iOQ}\4 olt$<'+':~~·Q$eu.d:11Q(JS:,t""u~~ '<-,,':? .. , wc,~w-<!..,~10~ {i:Pi;v)~. y;;~l.f~fiu .. ~-~~ ,2;2,:::;'f.~1'·,~;: }'J:1/i;,~ rr,;; .1 ,:. :,j·,-,:. -':k,,,;,c;-.;:•'.<)";::; ;;:-;,, ::';.. ,""::1f::~~,;,.l';;,;);',.':-,.~,,;r&-:ifl,4-::"rf'14;~," ,\1;,.,}"':,~.~~:M'i>li'BJ;f-::6'\;i:x.,:,:-::~"n.~.:1!?'.li£x~1v, ;,,6~•,,::,~~u:·i'.~,;v"'t't:'c2il?, ,r,:,,,:, ;'l,,;,.,;;,"''f>';r:,J;i,,;~ "/rJ;. ~"1'R-£;¼Ji.:.B:¥-':6.r'0t:;;,,, 'f£.-Jf~. ~,r;~~aA·0{;:,:i§; 41 111-30-8 L 50 Glutaric Dialdehyde [Microbiocide) CR, SN 30.1421 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material [f rident 7 420) [1,5-Pentanedial] Storage [New] (Glutaraldehyde] [Cidex] (Omnicide 28) (NALCO 2838) (25-50% Solution in Water) [BP: 212oF; FP: None] [pH: 4.1][HR: H3 COR) 42 56-81-5 L 100 Glycerin [Glycerol) [1,2,3-Propanelrlol] CL3B, IR, OHH 29.8515 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material (Laemmuli Sample Buffer) (FP: 320oF; Storage (New] BP: 1820] [HR: H1 F1) 43 56-40-6 S 100 Glycine[AminoaceticAcid)[L-Glycine) NH 906.1000 Lbs 0.0000 Lbs 0.0000 Lbs 140/RawMaterial [RTECS# MB7600000) [HR: OJ Storage (New) 44 593-84-0 S 100 Guanidine lsolhiocyanate [Guanldine IR 2.2100 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Thiocyanate) (MP: 120oC] (RTCS# Storage (New) XL 1225000J[HR: H2) ------------------------------------------------------------------ 45 50-01-1 S 100 GuanidineMonohydrochloride[Guanidine IR,TX 131.4950 Lbs 0.0000 Lbs 0.0000 Lbs 140/RawMaterial Hydrochloride) [MP: 1850] [LD50-0: 475 Storage (New) mg/kg) (RTECS# MF4300000) [HR: H3J -------~-·-·----------------------------------------''----------------- 46 7365-45-9 S 100 HEPES (4-(2-Hydroxyethyl)-1-IR 2.8730 Lbs 0.0000 ' Lbs 0.0000 Lbs 140/Raw Material Piperazineelhane Sulfonic Acid) [N-2-Storage (New) Hydroxyelhylpiperazine-N'-2- Elhanesulfoni_c Acid) [MP: 2340) (RTECS# TL6809000) [HR: H1) 47 10534-89-1 S 100 Hexaminecobalt(III) Chlorkle [MP: 2170) IR, OHH 0.276_3 Lbs 0.0000 Lbs 0.0000 , Lbs 140/Raw Material [HR: H2J Storage (New) 48 7647-01-0 L >/=50-100 Hydrogen Chloride (Hydrochloric Acid) CR, PSM, RMP-T1 4.1211 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material [Muriatic Acid] [50-100%] [HCIJ [Acid)[pH: Storage [New) <1} [LD50-0: 900 mg/kg; LC50: 3,124 -ppm) [HR: H3 CORJ 49 123-31-9 S 100 Hydroquinone [Dihydroxybenzene) IR, OHH, TX, RMP-0.1989 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [Hydroquinol) [Quinol) [LD50-0ral: 320 T3 Storage [New) mg/kg) [HR: H3) 50 5470-11-1 S 100 Hydroxylamine Hydrochloride [Stabilized) CR, OHH, SN, UR2 0.4420 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [Reducing Agent, Catalyst) (RTECS# Storage [New) NC3765000) [HR: H3 R2 COR] ---------····-···------------------------------------------------------- 51 288-32-4 S 100 lmidazole [MP: 89oC; BP: 256oCJ [HR: CR 13.2600 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material H3 COR] Storage [New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only -no use conditions. Building is protected throughout by an automatic fire sprinkler system. ~--~ .. "·-~ ~ ,_ ~--tllllllllll!I. ~ -.. .. -;r··-TTJ r--·T 2.--"·-·· > -y····· r·T-.. 04-23-01 Page6 lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2-Room 140/Raw Material Storage: Hazardous Materials Inventory 11"~tit!·ft,.;1iiri'i~r1ttJ:tt:t~~<~~>w.1;r,;ti-i . ~1~11;1i.;'~isJ"Y,:i{itu:,;t~t;Ul~)ai1i::.ttm~0l~l'*"Zivfif~~c" iti'ljr§th1?r~(iif:lf~l~·;11 ID~~ -,:,Jf/21::.7~~:,,,;±;~:i~;;~Ji'JZ? rt\:t1\~~$ir:f:..y,;-~~~~'fl r)Jf~)-X:k-~i!~tf-;~:.:Rt~~hW..iif)].!fi~,::,..\-i'"Y,,'IJl-Zf4~llh:..~~~£~~~i£'Jt1v~,-Wr.:?:%x~:!t,,kl ··~tt·d:diStJ 52 305-53-3 s 100 lodoacetlc Acid Sodium Salt (HR: H3] IR,TX 0.6188 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Storage (New) 53 · 123-51-3 L 100 lsoamyl Alcohol (Methyl-1-Butanol (3-)) CL2,IR,SN 0.0740 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material (lsopentyl Alcohol) [FP: 114oF; BP: Storage [New] 130oF] [LEL: 1.2; UEL: 9.0) (HR: HZ F2) 54 67-63-0 L >/=70 lsopropanol (lsopropyl AlcohoO (2-FL1B,IR 7.3968 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material Propanol) (Alcohol) [Alpha 870-25 Solder Storage [New) Flux) (Omega Meter Test Solution) [425 Thinner] [LD50-0: 5,840 mg/kg; LD50-S: 13,000 mg/kg) [FP: 53oF; BP: 82.5oC) (LEL: 2.5%; UEL: 12%] (HR: H2 F3) 55 25389-94-0 s 100 Kanamycin Monosulfate (HR: H1] OHH 0.0111 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Storage [New) -·----··-·- 56 56-87-1 s 100 Lysine (L-) [L-Lysine Monohydrate] [L-NH 100.0000 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Lysine Hydrate) [2,6-Diaminohexanoic Storage [New] Acid) (RTECS# OL5540000) [HR: OJ 57 7791-18-6 s 100 Magnesium Chloride Hexahydrate (LD50-IR 7.9560 Lbs 0.0000 . Lbs 0.0000 Lbs 140/Raw Material 0: 8100 mg/kg) [RTECS# OM2975000] Storage [New) (HR:H1] --·---- 58 10034-99-8 s 100 Magnesium Sulfate Heptahydrate (Epsom NH 1.1713 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Salts] [RTECS# OM4508000) [HR: OJ Storage [New] 59 13446-34-9 s 100 Manganese(II) Chloride Tetrahydrate IR,OHH 0.6630 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material (Manganese Chelazome] [LD50-0: 1484 Storage [New] mg/kg) [RTECS# 009625000) (HR: H2) 60 18598-63-5 s 100 Mecysteine Hydrochloride (Zeolin] [MP: OHH 5.5250 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material 14op] (LD50-0ral: 30 g/kg) [HR: H1] Storage [New] 61 4420-74-0 L 100 Mertapcopropyllrimethoxysilane CL2,IR,WR1 0.2642 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material [frimethoxysilyl Propanethiol] [BP: 19&o; Storage [New] FP: 120oF) (RTECS# TZ7800000) (HR: H2 F2 R1] 62 145224-94-8 s 100 MES Monohydrate [4-IR 132.6000 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Morpholineethanesulfonic Acid) [MP: Storage {New) >300oF) [HR: H1) ---~----· LEV: Lacal or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only -no use conditions. Building is protected throughout by an automatic fire sprinkler system. ·----' [:--,,_ (, __ ~ ~ tllal z.... ~ ~ (;-~-; ~ ~ ~ y-~ '~ ~ r_··--.. -w ~ ~ ~ ; ,. ... 04-23-01 Page7 lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage: Hazardous Materials Inventory ~~"flW{ij~-~G~l-·1:.#j~~'i!,¥if~ttr,J~~r:E,;;J'1tJ::;,:,;;~tf::&~~,!Q~f~,~f'f:1fft'-1~Y~~r~s:oi!i@1'tt~i -·:~tito"~~i1,:P:if~~~~'!~1f1lf{i:,i'.WfaH ~ :.-:~~i{~~'S~%¼:--Y-:1@;~~~ -~',:~i~t~f._~~~t,t-4Eli4/1f~¥0:tf?,:~1:il~-¥i~tf;{~~q,~41-f-:-:'0.~~ p?f~~rff¥P~J!l1..+v-tt.;;::ti•r-~'f..~?,;._;:,iJ.-.:.r~i ~;.?·:,-r~r~i~R0_J¥.0s.a.~~J~:~ t~~~~~S'i ~ rc->!;.1r.i2:~ -,, --; iJ,,;};;~i -Jt~~~,~--!· 63 67-56-1 L >/=50 Methyl Alcohol [Methanol] [Wood Sealer] FL18, IR 11.6236 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material [Pen Fix] [Reagent Alcohol] [Blue Blox] Storage [New) [FP: 52oF; BP: 64.7oC/148oF) (LEL: 6%; UEL: 36.5%] [Autoignition: 878oF] (Vapor Pressure: 100mm @21.2oC] [FV per Gin: 1270] [HR: H2 F3] 64 617-04-9 s . 100 Methyl-a-D-Mannopyranoside [a-OHH 0.4420 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Methylmannoside] [Methyl-a-D-Storage [New] Mannoside) [HR: H1] 65 110-26-9 s 100 Methylene(bis)Acrylamide (N,N'-) (Bis-) IR,TX 53.0400 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [Electrophoresis Reagent) [BIS] [HR: H3) Storage [New] 66 1132-61-2 s 100 MOPS (4-MorphoDno-Propanesulfonic IR 1240.4730 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Acid] [MP: 277oCJ [RTECS# Storage [New] QE91045330] [HR: H1] 67 1132-61-2 s 100 MOPS (4-Morpholino-Propanesulfonic IR 105.1960 Lbs 0.0000 'Lbs 0.0000 Lbs 140/Raw Material Acid] [MP: 277oC] [RTECS# Storage [New] QE91045330] [HR: H1) 68 7791-20-0 s 100 Nickel(!!) Chloride Hexahydrate [RTECS# CA, IR, OHH, P65 2.2100 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material QR6475000] [HR: H2) Storage [New] 69 2001-000-20 L 100 Oxidizer SoluUon (0.2M Iodine Solution In FL1B, IR 0.1585 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material Tetrhydrofuran/109-99-9, Pyridine/110-86-Storage [New) 1) [HR: H2 F3] 70 00-01-608 L 100 Penicillin-Streptomycin Sulfate Solution IR,OHH,SN 0.0264 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material [FP: None] [HR: H2] Storage [New] 71 108-95-2 s 100 Phenol [Carbolic Acid] [LD50-0: 317 CR, FS, OHH, TX, 0.4420 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material mg/kg; LD50-S: 669 mg/kg; LC50: 316 RMP-T3 Storage [New] mg/m3] [HR: H3 F2 COR] 72 15593-04-9 L 100 Phenol Chlorofonn lsoamyl Alcohol [BP: CL3B,CR, TX 0.1057 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material 2290; FP: 240oF] [HR: H3 F1 CR] Storage [New) ---~-----· 73 13822-28-1 L 50 Phenol Red [1,4'-(3H-2, 1-Benoxathiole-NH 5.0000 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material 3,3-Diyl)Diphenol,S,S-Dioxide] [pH 6.8-Storage [New) 8.2] [FP: None] (HR: OJ LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only --no use conditions. Building is protected throughout by an automatic fire sprinkler system. :__ ~-:JIii 04-23-01 ;;-~ .. ~---,-· ,. ··-~ -~ r·-·-"· er·· ~ ...... ~ r··-----... lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2 -Room 140/Raw Material Storage: Hazardous Materials Inventory 74 7664-38-2* L >50 Phosphoric Acid [H3PO4] [Portein Assay] CR 4.6230 Gins 0.0000 0.0000 Gins [BP: 232oF) [Acid-Inorganic] [LD50-O: >4,400 mg/kg; Lp50-S: >3,260 mg/kg] [pH: 1.5) [RTECS# TB6300000) [HR: H3 COR] ----· 75 9002-89-5 s 100 Poly(Vinyl Alcohol) [Mowiol 40-88] CD 0.5304 Lbs 0.0000 Lbs 0.0000 Lbs (Gelvatol) [Polyvinyl Alcohol Resin) [RTECS# TR8100000] (PVA] [HR: F2) 76 25322-68-3** s 100 Polyethylene Glycol [PEG) [Poly(Ethylene IR 852.3970 Lbs 0.0000 Lbs 0.0000 Lbs Oxide)] [Carbowax] (Polyox] [Pluracol P- 410) (HR: H1] 77 9002-92-0 s 100 Polyoxyethylene Sorbitan Monolaurate IR 100.0000 Lbs 0.0000 Lbs 0.0000 Lbs (Laury! Ether] [fhesit] (a-Dedecyl-a- Hydroxy-Polyoxyethylene) (Brij 35] [Polidocanol] [Lubrol) [HR: H2] 78 2001-000-154 s 100 Ponasterone A (Analog of Ecydsome) IR 1.1050 Lbs 0.0000 Lbs 0.0000 Lbs [lnvitrogen H101-01; H101-03) [HR: H1) 79 127-08-2 s 100 Potassium Acetate [Acetic Acid, IR 4.0664 Lbs 0.0000 Lbs 0.0000 Lbs Potassium Sall] [RTEDS# AJ3325_000] [HR:H2] 80 7758-01-2 s 100 Potassium Bromate [BromicAcid, CA, OHH, OX3, 1.6575 Lbs 0.0000 Lbs 0.0000 Lbs y Potassium Sall) [MW: 167.01) [LD50-O: TX,P65 321 mg/kg] [HR: H3 OX3) ---------- 81 584-08-7 s 100 Potassium Carbonate [MP: 891oC) IR 24.3100 Lbs 0.0000 Lbs 0.0000 Lbs (RTECS# TS7750000) [HR: H2] 82 7447-40-7 s 100 Potassium Chloride [Potash) [f urf IR 2.2100 Lbs 0.0000 Lbs 0.0000 Lbs Supreme w/Bestcote 15-5-7; 20-0-20; 6- 20-20) [Ultra King Greens Cote 18-4-10) [with </=2% Iron Oxide) [pH 9.2) [HR: H1] 83 14459-95-1 s 100 Potassium Ferrocyanide(II) Trihydrale IR,TX 1.7680 Lbs 0.0000 Lbs 0.0000 Lbs [Potassium Hexacyanoferrate(II)) [MP: 70oC] (HR: H2] 84 1310-58-3 s >/=85 Potassium Hydroxide [Caustic Potash] CR, TX, WR2 0.8840 Lbs 0.0000 Lbs 0.0000 Lbs y [Caustic-Base] [LD50-Oral: 365 mg/kg] (KOH) (RTECS# TT2100000] (pH: 12] [HR: H3 R2 COR WR] --------· ·-·-··--·- ~------.. .. fiiil Page8 140/Raw Material Storage [New) 140/Raw Material Storage [New) 140/Raw Material Storage [New) 140/Raw Material Storage [New) 140/Raw Material Storage [New] 140/Raw Material Storage (New) 140/Raw Material Storage [New] 140/Raw Material Storage [New] 140/Raw Material Storage [New] 140/Raw Material Storage [New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only -no use conditions. Building is protected throughout by an automatic fire sprinkler system. ,--~--;·-:)-_, _ _ ., -'-'------ i ' - • 04-23-01 -;,aaa ~ .. -,_ --.. -,,_ ~ lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 2-Room 140/Raw Material Storage: Hazardous Materials Inventory ~~~~¼i~~~t~~11~J!J~1if~:i~~~1~~i~~7?.~~~~~~t~~,~ai~~-l!~i~g~1r~!lml~~111~~~~~~J~~j~j 65 7758-11-4 s 100 Potassium Phosphate Dibasic [HR: OJ NH 22.3210 Lbs 0.0000 Lbs 0.0000 Lbs -- 66 7778-77-0 s 100 Potassium Phosphate Monobasic IR 4.4200 Lbs 0.0000 Lbs 0.0000 Lbs [Potassium Dihydrogen Phosphate] [HR: H1)· 67 110-86-1 L 100 Pyridine [Azabenzene) [Azine) [FP: 68oF; FL1B, tR 5.0000 Gins 0.0000 Gins 0.0000 Gins y BP: 115oF] [LD50-0: 691 mg/kg; LD50- S: 9010 mg/kg) [HR: H2 F3) 68 7761-68-6 s 100 Silver(I) NitrateJMP: 2120) [RTECS# CR,OX1 22.1000 Lbs 0.0000 Lbs 0.0000 Lbs y VW4725000] [HR: H3 COR OX] --------- 69 6131-90-4 s 100 Sodium Acetate Trihydrate [Acetic Acid IR 1.1050 Lbs 0.0000 Lbs 0.0000 Lbs Sodium Salt Trihydrate) [MP: 3240) [RTECS# AJ4300010) [HR: H2) 90 26626-22-6 s 100 Sodium Azide [Nondetonatable] [LD50-HT, UR3, WR2, 1.1603 Lbs 0.0000 Lbs 0.0000 Lbs y Oral: 27 mg/kg; LD50-Skin: 20 mg/kg) RMP-T3 [HR: H4 R3 WR) --- 91 7661-14-5 s 100 Sodium Bisulrate [Sodium Acid Sulfate) IR 100.0000 Lbs 0.0000 Lbs 0.0000 Lbs [HR:H2 IR] 92 7631-90-5 s 100 Sodium Bisulrite [Sodium Hydrogen IR 77.3500 Lbs 0.0000 Lbs 0.0000 Lbs Sulfite) [RTECS# VZ200000) [HR: H2)' 93 497-19-8 s 100 Sodium Carbonate [Soda Ash) [Disodium IR 3.3150 Lbs 0.0000 Lbs 0.0000 Lbs Carbonate] (Carbonic Acid, Disodium Salt] [Crystal Carbonate] [pH: 11.2) [LOSO- O: 4,090 mg/kg] [RTECS# VZ4050000] [HR:H1) 94 7647-14-5 s 100 Sodium Chloride [Salt] [Normal Saline] IR 192.7120 Lbs 0.0000 Lbs 0.0000 Lbs [Isotonic Sall) [RTCS# VZ4725000) [HR: H1] 95 55049-46-4 s 100 Sodium Citrate [Potassium Citrate] [Citric IR 1.9006 Lbs 0.0000 Lbs 0.0000 Lbs Acid] [HR: H1] ------- 96 151-21-3 s 100 Sodium Dodecyl Sulfate [Dodecyl Sulfate IR 117.5720 Lbs 0.0000 Lbs 0.0000 Lbs Sodium Salt] Sodium [Laury! Sulfate) [SDS) [Sigma L6026) [RTECS# WT1050000] [HR: H1] --------~- f;-,_ ... .. Page9 140/Raw Material Storage [New] 140/Raw Material Storage [New] 140/Raw Material Storage [New) · 140/Raw Material Storage [New) 140/Raw Material Storage [New) 140/Raw Material Storage [New) 140/Raw Material Storage [New) 140/Raw Material Storage [New] 140/Raw Material Storage [New] 140/Raw Material Storage [New] 140/Raw Material Storage [New) 140/Raw Material Storage [New) LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLY-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only -no use conditions. Building Is protected throughout by an automatic fire sprinkler system. .· .. lllllll'._lllli!lllll&.1111111 :,_ ~ ... {; -] . •. ~ -,.--. " --,--···----.. .. -.. . 04-23-01 Page 10 lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 2-Room 140/Raw Material Storage: Hazardous Materials Inventory ~I···· :,tf~~~l;;·,;;:tit"'ii~~ · ~1;:. ,j,.""~,·1:tlff&=1i;;;:-""h'it{ij~'r," :11Ie :':'E.~miUi'~! s'/4¾r:-.:;s:.f;'w., , .::v.~ i;;ti~,z'-'-~!:.,;, .-s..l:k:',Li~~~:a~S?'¼i~J.{,i;..'."i.JW.fu1~u,:e,· x.' J,,t,.ifQ:'ffe.ff!; 97 68915-31-1 s 100 Sodium Hexametaphosphate [Sodium IR 13.2600 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Hexamelaphosphate] (Base] [HR: H1] Storage [New) 98 1310:73.2 s >50 Sodium Hydroxide [Caustic Soda) [Base] CR,TX, WR1 3.3150 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [Lewis Red DeVil Lye Drain Opener) [APC Causllc Alkaline Cleaner] [APC 500 Storage [New] Heavy Duly Caustic Cleaner] [Cycle AL- 100] [LOSO-Oral: 140-280 mg/kg} [NAOH] [HR: H3 R1 COR WR] 99 7681-52-9* L >/=12.5 Sodium Hypochlorite [Aqueous Solullon] CR,OX1 0.2641 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material [>/=12.5% Solution] [Autoclean) (Bleach] Storage [New) (Cycle SH-100] [SB-Chlorinate] [BP: 111oC; FP: None] [RTECS# NH3486300] [HR: H3 COR OX] 100 7681-82-5 s 100 Sodium Iodide [RTECS# WB6475000] IR,WR1 15.9120 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [HR:H2R1] Storage [New) 101 7558-79-4 s 100 Sodium Phosphate Dibasic (Sodium IR 5.9670 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Dihydrogen Phosphate) [Disodium Storage [New] Phosphate) [Sodium Hydrogen Phosphate] [Disodium Hydrogen Phosphate] [Na2HPO4) [HR: H1] 102 7558-79-4 s 100 Sodium Phosphate Dibasic (Sodium IR 8.1770 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Dihydrogen Phosphate) [Disodium Storage [New} Phosphate] (Sodium Hydrogen Phosphate] [Diso~ium Hydrogen Phosphate) [Na2HP04) [HR: H1) 103 7757-83-7 s 100 Sodium Sulfrte [LD50-O: >2,825 mg/kg] IR 0.2210 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [RTECS# WE2150000) [HR: H1] Storage (New) 104 7772-98-7* L </=50 Sodium Thiosulfate [Sodium Hyposulfite] IR 1.1888 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material [Aqueous Solution) [FP: None) [RTECS# Storage [New] XN6476000) [HR: H1) 105 2001-000-130 L 100 Solvent Mixture (AceticAnhydride/108-24-CR, FL1B, WR1 0.1585 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material 7; Pyridine/110-86-1; Storage [New) Tetrahydrofuran/109-99-9] [HR: H3 F3 R1 CORJ 106 21736-83-4 s 100 Spectinomycin Hydrchorlde [LOSO-Oral: IR 0.0663 Lbs 0.0000 · Lbs 0.0000 Lbs 140/Raw Material >5 g/kg) [HR: H1] Storage [New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only -n.o use conditions. Building is protected throughout by an automatic fire sprinkler system. ~~~-~~-wwwwrn-as·,,-··1-~-~-na 04-23-01 Page 11 lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2-Room 140/Raw Material Storage: Hazardous Materials Inventory ,;;;~~t«.;;,yt.;nf;iJ}f~;'e;'§:;,,tf tJl'E"i'.eZ-+S·:"·iii~<ii,"'[l l6fil'i ,m•t~l~·";Jt\Y f/K'Pi"'P~ftt· :;a~ir.-mt\ij':;Uf;:,,ty"",S :'¥t,_lf'lt-' {j;,;,, 'lll!'.lf.1 ~.1;JJ~~!~~li~r~t~~~<Ii~ii1;,4t,jt:~~~~. :1:~~~~fift~~~-~,:J~}~i1tt~t?ML~MQJ!;1W~l:M~]~~5µ~4:•J,, 11~~,~~ :}t~~!tj.fil&~11~<-~{~i!}1i/ty-r: ;~'t y_;i~l 107 7664-93-9 L 67-100 Sulfuric Acid [H2SO4] [Acid] [LC50-CR,TX,WR2, 1.0567 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material Inhalation: 254 ppm] [LD50-0ral: 2,140 RMP-T3 Storage [New] mg/kg] [pH: 0.3] [DOT Class 8]/PG II) [HR: H3 R2 COR WR) 108 110-18-9 L 100 TEMED [N,N,N',N'-CR, FL1B 0.6604 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material Tetramelhylelhylenediamlne] [BP: 1200; Storage [New] FP: 50oF] [RTECS# KV7175000] [HR: H3F3COR] 109 60-54-8 s 100 Tetracycline Free Base [HR: H1] IR,OHH,P65 0.0111 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Storage [New] ----- 110 109-99-9 L 100 Telrahydrofuran [FP: 1oF; BP: 69oC) FL1B,IR 5.0000 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material [I.EL: 1.8; UEL: 11.8) [l.050-0: 2,8156 Storage [New] mg/kg) [RTECS# LU5950000) [HR: H2 F3] 111 288-94-8*, L 10 Tetrazole (1-H-) [10% in Acetonilrilell5-FL18, IR, UR2 0.4755 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material 05-8) [HR: H2 F2 R2) Storage [New) 112 67-03-8 s 100 Thiamine Hydrochloride [Vitamin B1 IR 1.3260 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Hydrochloride) [Aneurine] [MP: 248oC] Storage [New] [RTECS# X1735000) [HR: H1J 113 1326-12-1 s 100 Thioflavln S [Cl 49010) [Direct Yellow 7) NH 0.2431 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [RTECS# TV1050000J [HR: OJ Storage [New] 114 6001-64-5 s 100 Trichloro-2-Melhyl-2.Propanol Hydrate IR 1.1050 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material (1,1,1-) [Chlorobutanol](HR: H1] Storage [New] 115 76-03-9 s ' 100 Trichloroacetic Acid [LD50-0: 400 mg/kg] CR, TX 10.0000 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [RTECS# AJ7875000] [HR: H3 COR] Storage [New] 116 5704-04-1 s 100 Tricine [Tris(Hydroxymethyl)Melhyl IR 375.7000 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material Glycine) [pH 7.6-8.8) [HR: H1] Storage [New) 117 9002-93-1 L 100 Triton X-100 (Octylphenoxypolyethanol) CL3B,IR 7.6610 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material (Octoxynol 40] [FP: >550oF] [pH: 6-8) Storage [New] [L050-O: 1,800 mg/kg] [HR: H2 F1] 118 77-86-1 s 100 Trizma Base [THAM) JR 1151.6300 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [Tris(Hydroxymelhyl)Aminomelhane) (2-Storage [New] Amino-2-(Hydroxymethyl)-1,3- PropanedlolJ [TRIS] [Tromethane] [HR: H1] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only -no use conditions. Building is protected throughout by an automatic fire sprinkler system. ::.______ :· :--~-,_ ~ "-r.:....._ t -[-.. ~-~ . .. --... -. t -.. --.. , 04-23-01 Page 12 lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 2-Room 140/Raw Material Storage: Hazardous Materials Inventory 119 72-57-1* L Trypan Blue [Aqueous Solution] [Cl CA,OHH,P65 0.0528 Gins 0.0000 0.0000 Gins 23850] [Direct Blue 14] [Nlagra Blue 3B] . (Aqueous Solution] (FP: None] [RTECS# QJ6475000] (HR: H2] 120 9005-64-5 L 100 Tween 20 [Polyoxyelhylene (20) Sorbitan CL3B, IR 0.0528 Gins 0.0000 Gins 0.0000 Gins 140/Raw Material Monolaurate] [FP: >200oF) [HR: F1 H1] Storage (New] 121 57-13-6 s 100 Urea (Urea Prilij [Carbamidic Acid] (MP: IR 233.1550 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material 133oC] (LD50-0: 14,300 mg/kg] Storage [New] [RTECS# YR6250000] [HR: H1] 122 100-43-6 L 100 Vinylpyridlne (4-) [4-Ethenylpyridine] [FP: CL2, CR, SN, TX, 0.0066 Gins 0.0000 Gins 0.0000 Gins y 140/Raw Material 125oF; BP: 62oF] [RTECS# UU1045000) UR1 Storage [New] [HR: H3 F2 R1 COR] 123 2001-000-155 s 100 Zeocin [Cayla ZEOCP0001, 0005) OHH 5.5250 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [Phleomycin D1/Bleomycin Antibiotic] Storage [New] [HR:H1] 124 7646-85-7 s 100 Zinc Chloride (LOSO-Oral: 350 mg/kg) CR,OHH, TX 3.3150 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [RTECS# ZH1400000] [HR: H3 COR] Storage (New] 125 7646-85-7 s 100 Zinc Chloride (LOSO-Oral: 350 mg/kg) CR,OHH,TX 1.1050 Lbs 0.0000 Lbs 0.0000 Lbs 140/Raw Material [RTECS# ZH1400000] [HR: H3 COR] Storage [New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combui;;tible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage only -no use conditions. Building is protected throughout by an automatic fire sprinkler system. -~ 11 ll "'"'1 I~ IJ ll IJ I 11, ll I I II .11 II I Ii I! I ll INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 11 May 2001 [Rev.1] Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue L!:! Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net I I I II I I I \I I I I ,,,. ,. ! I i ~I ;I I I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 11 May 2001 [Rev. 1] Prepared by 'f' Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net ·-,..... ~----,.,. .. ']Iii.. ;,.... ~ tiliiiliill. ,;iliiiliia ~--------l.... L..-. .. ~ ~ ~ ------~ HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS \iilifilliiill ~ ••-• ;-a--·1 · -r --· · ff· ··1 UBC/CBC TABLE 3-D-UFC/CFC TABLES 7902.S~A, 7903.2-B, 8001.15-A SUMMARY -PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3 STORAGE USE CLOSED Solids Liquid Gas Solid Liquid Gas Solid Material Lbs Gins Cf Lbs Gins Cf Lbs Combustible Liquids II ·2.5330 Combustible Liquids Ill-A 20.6055 ••w• Combustible Liquids 111-B 111.3728 Flammable Liquids 1-B 70,2252 Flammable Liquids 1-C 40.2097 Flammable Solids 0.0664 Unstable Reactives 2 3.0116 Unstable Reactives 3 0.7735 Water Reactives 1 3,9890 Water Reactives 2 1.2155 1997/1998 CODES -CONTROL AREA 3: B/ F1/S1 OCCUPANCY CONDITIONS BASED ON THE USE and STORAGE OF PHYSICAL HAZARD MATERIALS. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic; fire sprinkler system. --,·····: .. USE OPEN Liquid Gins 21.1603 --19.8130 --105.6691 3.6984 ---39.6259 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 1 t-'lliiililiia ~ Gas Cf - .. ·-·-·· :-·,.~ r..:.-U ~~ ~----~ r·-·-·· ',:,···1 ft.aiilliiiill t....._ r1·---·, 1:.·-~ .. r-1·~-. ,, rr~-, HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-D -UFC/CFC TABLES 7902.5-A, 7903.2-8, 8001.15-A SUMMARY -PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3 ~-o···,..t.:: .. s-t'"J:.l''ref#-1,•i:,,""'t~~·c,r·?'l1-'.iz -,,::,,~ l%··e-~w.;i;y,: ~·-,;,-,, r ~::,J,~~t~ -,:~M ~-~~9.:~~~~~J;,t,:;!£1(~;£1~;-~¢;?~~?,ht,4lJ!{J::]-~~~:v~¥~ ~iif: l~J!trtil) tMdtfs:\I 2.5330 TOTAL Combustible Liquids II (LIQUIDS] AGGREGATE TOTAL Combustible Liquids II JLIQUIDSJ: ~ GALLONS LIQUIDS HAVING FIRE POINTS -1997 UBC TABLE 3-D/UFC TABLE 7902.5-A EXEMPT AMOUNTS PER CONTROL AREA: STORAGE & USE CLOSED -H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. USE OPEN & PRESSURIZED SYSTEMS >15 PSIG -H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 240 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: . 480 GALLONS, USE CLOSED EXEMPT AMOUNT: 240 GALLONS USE OPEN EXEMPT AMOUNT: 60 GALLONS LIQUIDS WITHOUT FIRE POINTS -1997 UBC TABLE 30D/UFC TABLE 7902.5-A, 7901.1.1/Exception 9 EXEMPT AMOUNTS PER CONTROL AREA: STORAGE: UNLIMITED . USE CLOSED EXEMPT AMOUNT: 240 GALLONS USE OPEN EXEMPT AMOUNT: 60 GALLONS MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1.1/EXCEPTION 3: </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED GROUP M OCCUPANCY. MAXIMUM QUANTITIES PER CONTROL AREA-1997 UFC TABLE 7902.5-B -COMBINATION 1-B, 1-C, II, Ill-A: CEILINGS </=18' HIGH· </=6' SHELF STORAGE, </=4.5' OTHER STORAGE: 7,500 GALLONS SPECIAL SPRINKLER SYSTEM PROTECTION: 15,000 GALLONS Gins ,., , "¼J;i,#if.1€,)ih,t,)P,,.=-,,.,, •• ,,.,.,~,,,.,, ""IMi ... ij .... in-,t'.~lt""·~-··,..,;1 1'~111 J:~:.t-rr,,;;t~!-t!,' '>f, { · ,, · ,,,, "-'-•l-4fiii"''t:'ft'' ,i,aS!Jrtt:11.,;i· ,t~aE. ·rs ... _m, . .,"'~::¼1t . . . -,-,g,9im~~,,~. ~?t,.:-:. ,,q,,,-i ~..-r/y_t,•~:,#t~%t?¼~Zt/4t~r zi~ .. .-:.;f:i~J '•~~~~-: TOTAL Combustible Liquids Ill-A [LIQUIDS) AGGREGATE TOTAL Combustible Liquids Ill-A (LIQUIDS]: 20.6055 40.4185 GALLONS LIQUIDS HAVING FIRE POINTS -1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA: STORAGE & USE CLOSED -H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. USE OPEN & PRESSURIZED SYSTEMS >15 PSIG -H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 660 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 1,320 GALLONS USE CLOSED EXEMPT AMOUNT: 660 GALLONS USE OPEN EXEMPT AMOUNT: 160 GALLONS LIQUIDS WITHOUT FIRE POINTS-1997 UBC TABLE 30D/UFC TABLE 7902.5-A, 7901.1.1/Exception 9 EXEMPT AMOUNTS PER CONTROL AREA: STORAGE: UNLIMITED USE CLOSED EXEMPT AMOUNT: 660 GALLONS USE OPEN EXEMPT AMOUNT: 160 GALLONS MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1.1/EXCEPTION 3: </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED GROUP M OCCUPANCY -MAXIMUM QUANTITIES PER CONTROL AREA-1997 UFC TABLE 7902.5-B • COMBINATION 1-B, 1-C, II, Ill-A: CEILINGS </=18' HIGH· </=6' SHELF STORAGE, </=4.5' OTHER STORAGE: 7,500 GALLONS . SPECIAL SPRINKLER SYSTEM PROTECTION: 15,000 GALLONS CONTROL AREA 3: B/F1/S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds Into storage vessels. Gins t.r-·-1 rr··n ., ....... ] ?ff ··1 er· ·1 ,~m~ 0.0000 Gins 21.1603 Gins Wnfill UIMP-2J litttli:I 0.0000 Gins 19.8130 Gins SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/223/2001 -PAGE 2 9---==--- .. .. :'-~ ,--·-· l .. 'fl" .. .. HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS :,-~---. I --··· ... ,,,----. ;1-[ra UBC/CBC·TABLE 3-D • UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY-PHYSICAL HAZARD MATERIALS lnvitrogen -1'600 Faraday Avenue, Carlsbad CA-Control Area 3 "'"·",:at,F·t·6i''"*s•··r.1a··,,.,,··1·5,r::i''"'J!.iZ-~"'·'', ·:-;,,;:-,,r,--, .• ,_,.,,;:'J."'''''''•¾' ~9l~:,L~,t,~-,J~i~~~-!1\~s~h®;r~1:%~;?~~1liB'SL4:-½}~fUf½'~i~A'tt~ TOTAL Combustible Liquids 111-8 [LIQUIDS) AGGREGATE TOTAL Combustible Liquids 111-B (LIQUIDS): '-'Si :J: l'ffij ~ ,"'>:' ?;JgJJ~~ 111.3728 217.0419 GALLONS Gins .. :r· .. -·, ·1T···a .. - t~MitW~ ~ ' fk:,'.~~~I :~Tu~,:.-,.~~~-3 ,,t: mill , 0.0000 Gins 105.6691 Gins 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA· H OCCUPANCY NOT REQUIRED IN SPRINKLERED BUILDING. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: UNLIMITED STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: UNLIMITED USE CLOSED EXEMPT AMOUNT: UNLIMITED ·use OPEN EXEMPT AMOUNT: UNLIMITED MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1/EXCEPTION 3 • . </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED ~~ofagei tim1~-..'I 'Y, ~~1Jtf'.. .,,.,,.,~;:: ~-m ltYni~it ;.;o:2t,:~"""I 1·omfi;I fJkll¼•":;. ,..~~ }~..t~~f TOTAL Flammable Liquids I-B (LIQUIDS] 70.2252 Gins 0.0000 Gins 3.6984 Gins AGGREGATE TOTAL Flammable Liquids I-B (LIQUIDS): 73.9236 GALLONS LIQUIDS HAVING FIRE POINTS -1997 UBC TABLE 3-D/UFC TABLE 7902.5-a EXEMPT AMOUNTS PER CONTROL AREA: STORAGE & USE CLOSED -H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. USE OPEN & PRESSURIZED SYSTEMS >15 PSIG • H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: 120 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 240 GALLONS USE CLOSED EXEMPT AMOUNT: 120 GALLONS USE OPEN EXEMPT AMOUNT: 30 GALLONS LIQUIDS WITHOUT FIRE POINTS -1997 UBC TABLE 30D/UFC TABLE 7902.5-A, 7901.1.1/Exception 9 EXEMPT AMOUNTS PER CONTROL AREA: STORAGE: UNLIMITED' USE CLOSED EXEMPT AMOUNT: 120 GALLONS USE OPEN EXEMPT AMOUNT: 30 GALLONS MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1/EXCEPTION 3: </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED GROUP M OCCUPANCY· MAXIMUM QUANTITIES PER CONTROL AREA· UFC TABLE 7902.5-B • COMBINATION I-B, I-C, II, Ill-A: CEILINGS </=18' HIGH -</=6' SHELF STORAGE, </=4.5' OTHER STORAGE: 7,500 GALLONS SPECIAL SPRINKLER SYSTEM PROTECTIOtf 15,000 GALLONS CONTROL AREA 3: B/F1/S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Liquids: Transfer from </=20-liter vessels Into storage vessels. Solids: Transfer of </=10 pounds Into storage vessels. SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC.· 04/223/2001 -PAGE 3 .. ~~--~~--,~--·---,---·vsa~·--·•-~n1r-·:1n1~~·--·--~--~--t.alalll f, .' t4. r, f : ~ L ' • • : :. • : : . . HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-D -UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY -PHYSICAL HA~RD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3 l~!to -~"'e~4 .. _,,;ffl!L.-. ~ ~ TOTAL Flammable Liquids I-C (LIQUIDS] AGGREGATE TOTAL Flammable Liquids I-C {LIQUIDS]: 40.2097 79.8356 GALLONS LIQUIDS HAVING FIRE POINTS a 1997 UBC TABLE 3-D/UFC TABLE 7902.5-A EXEMPT AMOUNTS PER CONTROL AREA: STORAGE & USE CLOSED -H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. USE OPEN & PRESSURIZED SYSTEMS >15 PSIG • H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT-NO CABINETS: 180 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 360 GALLONS USE CLOSED EXEMPT AMOUNT: 180 GALLONS USE OPEN EXEMPT AMOUNT: 40 GALLONS LIQUIDS WITHOUT FIRE POINTS -1997 UBC TABLE 30D/UFC TABLE 7902.5-A, 7901.1.1/Exceplion 9 EXEMPT AMOUNTS PER CONTROL AREA: STORAGE: UNLIMITED USE CLOSED EXEMPT AMOUNT: 180 GALLONS USE OPEN EXEMPT AMOUNT: 40 GALLONS MEDICINES, FOOD, COSMETICS, ETC. -1997 UFC 7901.1/EXCEPTION 3: </= 50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=4 LITERS: UNLIMITED GROUP M OCCUPANCY-MAXIMUM QUANTITIES PER CONTROLAREA-UFC TABLE 7902.5-B-COMBINATION 1-B, 1-C, II, Ill-A: CEILINGS </=18' HIGH -</=6' SHELF STORAGE, </=4.5' OTHER STORAGE: 7,500 GALLONS Gins SPECIAL SPRINKLER SYSTEM PROTECTION: 15,000 GALLONS s::•filffmiii.,'ltiS"i>l[d<>¥'l::~'1z:,., "'!<-&-::~:;.,: ;4Jr;!f£;1"'\;'"<:ti'~,..:7,:,,,. ·· ,~-5~ :11![wrieeT fnn1~j ~t•,,.'~;,, '">,r.::~.,-~.._,,...:,,<.!~,,,,~<<?!!('s;-,~,::«,,:1'>.1'<",A :,");...,..,,:";; ",•".;'';..i!,;,.~!,\f;";ff'.,+~-:1-r.-.,,Y-<1'"1:1~/. t"'t" Y>l"¼-~~---~ ~,;;.;;, TOTAL Flammable Solids [SOLIDS] AGGREGATE TOTAL Flammable Solids [SOLIDS]: 0.0664 Lbs 0.0664 POUNDS 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA· H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 250 POUNDS STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 500 POUNDS 0.0000 'Ci.?j,l'fO'i"'/~¼, lf.1:t~<}:i,'l?~ 0.0000 USE CLOSED EXEMPT AMOUNT: NOT APPLICABLE -NO FIRE/EXPLOSION HAZARD POTENTIAL USE OPEN EXEMPT AMOUNT: NOT APPLICABLE -NO FIRE/EXPLOSION HAZARD POTENTIAL CONTROL AREA 3: B/F1/S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Liquids: Transfer from </=20-llter vessels into storage vessels. Solids: Transfer of </=10 · pounds into storage vessels. lll"il ' Gins 11m.~1 Lbs ,"..:~UJifif' ~ ... <;-tt;:'.4;;f),.'-,, --~ 39.6259 ~f{l'f(!Y4$\'"'9 ~-twr11.:;mff>~:~ 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/223/2001 • PAGE 4 lmll . Gins l!tml~~, Lbs ~~~~~~r-,m1,s,~~-•~~w~-~~ HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-D -UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY -PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3 Y!X~J~r~1~~~I~Jr!l~l~~~Z,};}l\~~f~:i~~~~~~~~ TOTAL Unstable Reactives 2 (LIQUIDS] AGGREGATE TOTAL Unstable Reactives 2 [LIQUIDS): r·o+ffe''·'~f B~sl,~~ .. !iffiffl 3.0116 Gins 3.0116 GALLONS 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA -H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT-NO CABINETS: 100 POUNDS+ 10 GALLONS & 1,500 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 200 POUNDS+ 20 GALLONS & 3,000 CUBIC FEET USE CLOSED EXEMPT AMOUNT: 100 POUNDS+ 10 GALLONS & 1,500 CUBIC FEET USE OPEN EXEMPT AMOUNT: 20 POUNDS+ 2 GALLONS 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY-EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 900 POUNDS+ 90 GALLONS pc 'h~-. ~~·,, tf.½t~{~ ' T,. ~-...,Ja:'f "i.. ' 0.0000 1999 UFC SUPPLEMENT-RETAIL/WHOLESALE STORAGE/DISPLAY-EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 1,300 POUNDS+ 230 GALLONS 1997 UBC TABLE 3-G/UFC TABLE 8003.1-B -MAXIMUM AMOUNT PER BUILDING WITHOUT DETACHED STORAGE: GASES-10,000 CUBIC FEET ' LIQUIDS & SOLIDS -25 TONS 1999 UFC SUPPLEMENT -GROUP S OC~UPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 2,300 POUND$ + 230 GALLONS TOTAL Unstable Reactives 3 (SOLIDS) AGGREGATE TOTAL Unstable Reactives 3 (SOLIDS): 1997 UBC TABLE 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA. NONDETONATABLE -H-2 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. DETONATABLE-H-1 OCCUPANCY. REQUIRED ONLY FOR >EXEMPT AMOUNTS. ra~ttr'·;.ltil ~ :m-~!~~ ~ 0.7735 Lbs 0.7735 POUNDS STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 10 POUNDS+ 1 GALLON & 100 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 20 POUNDS.+ 2 GALLONS & 200 CUBIC FEET USE CLOSED EXEMPT AMOUNT: 2 POUNDS + 0.20 GALLON & 20 CUBIC FEET USE OPEN EXEMPT AMOUNT: 2 POUNDS + 0.20 GALLON FllyeJMiJI 0.0000 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 1,125 POUNDS+ 112.5 GALLONS 1997 UBC TABLE 3-GIUFC 8003.1-B-MAXIMUM AMOUNTS PER BUILDING WITHOUT DETACHED STORAGE: GASES-2,000 CUBIC FEET LIQUIDS & SOLIDS -1 TON 1999 UFC SUPPLEMENT-S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 1,100 POUNDS+ 110 GALLONS CONTROL AREA 3: B/F1/S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. ~ ~ Gins ~ ' Lbs .. :J;?~~~! 0.0000 iti!J~~~~ 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/223/2001 -PAGE 5 ~ ~ Gins ~ ' Lbs ~ -~-.. >;--. :.! ... iTtr; <'lr·1: ·r··-,: .. t .. {"Cl "ill 1th ·f---t~ .. .. ;:; ..... i .. HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-D • UFC/CFC TABLES 7902.5-A, 7903.2-B, 8001.15-A SUMMARY -PHYSICAL HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3 l¼S~"~ e;;1 lrn .. lffi ;,_.;t,~~~j)M<-;;< ~~A, ,,;,_r TOTAL Water Reactives 1 [LIQUIDS) AGGREGATE TOTAL Water Reactives 1 [LIQUIDS]: 3.9890 3.9890 GALLONS Gins 1997 UBC TABt.E 3-D/UFC TABLE 8001.15-A EXEMPT AMOUNTS PER CONTROL AREA· H OCCUPANCY NOT REQUIRED IN SPRINKLERED BUILDING. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: UNLIMITED STORAGE/AGGREGATE EXEMPT AMOUNT-WITH CABINETS: UNLIMITED USE CLOSED EXEMPT AMOUNT: UNLIMITED USE OPEN EXEMPT AMOUNT: UNLIMITED WiT'~r:is-;--~tw· ~~176'-!it/''*"' l' "''"":-'*'"''"!'JJmW1'~ "'':;';'j,t' .,,,:rr;' 1'< •.. l}~JiJ.,SiJ9----~~,;~;,~~~gf£:::·C~;~_$:--,~7.:t-~1f.i;~P-w~~;~~J.¥-!~i>~ 1,J3>JiJ1r~1 1:~m§lt 1.2155 Lbs TOTAL Water Reactives 2 (SOLIDS] AGGREGATE TOTAL Water Reactives 2 (SOLIDS]: 1.2155 POUNDS 1997 UBC TABLE 3-D/UFC TABLE 8001,15-A EXEMPT AMOUNTS PER CONTROL AREA· H-3 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. ·' STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: 100 POUNDS+ 10 GALLONS STORAGE/AGGREGATE EXEMPT AMOUNT· WITH CABINETS: 200 POUNDS+ 20 GALLONS USE CLOSED EXEMPT AMOUNT: 100 POUNDS+ 10 GALLONS USE OPEN EXEMPT AMOUNT: 20 POUNDS+ 2 GALLONS 1~:n~·-1,iJ, IM.rl'J h,$j"N~'~/4;;,;,>i. ,A-,~~ ~ 0.0000 Gins ~>n~g,E4t ~ ;:~;~Efil ~ 0.0000 Lbs 1997 UFC 8001.14 RETAIUWHOLESALE STORAGE/DISPLAY· EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 900 POUNDS+ 90 GALLONS 1999 UFC SUPPLEMENT -RETAIL/WHOLE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 2,300 POUNDS+ 230 GALLONS 1997 UBC TABLE 3-G/UFC TALBE 8003.1-B • MAXIMUM AMOUNTS PER BUILDING WITHOUT DETACHED STORAGE: GASES. 10,000 CUBIC FEET SOLIDS & LIQUIDS • 25 TONS 1999 UFC SUPPLEMENT· S OCCUPANCY STORAGE WITH 8001.14 STORAGE CON,DITIONS: 1,300 POUNDS + 230 GALLONS . CONTROL AREA 3: B/F1/S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Liquids: Transfer from <1=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds Into storage vessels. 0.0000 Gins ~,,,ga~· 11pn!i) \-%t.t~~7-~~i; ~ ,,,. A~ , < 0.0000 Lbs SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/223/2001 -PAGE 6 .. .. t-~--f .. '] ...... , - , .. .... . f-lliiiill .. ~ l.T .. t .... .. .. . .. ,.,-----, .. HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E • UFC/CFC TABLE 8001.15-B SUMMARY -HEAL TH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3 STORAGE USE CLOSED Solids Liquid Gas Solid Liquid Gas Solid Material Lbs Gins Cf Lbs Gins Cf Lbs Carcinogens 0.0884 1"0.2664 19.8900 -·- Corrosives 10.8533 186.9709 0.5283 Highly Toxics 0.7735 0.0264 Irritants 499.8049 345.9510 19.8900 Other Health Hazards 30.6638 69.4855 44.6317 Sensitizers 0.6844 Toxics 0.4663 28.3326 0.5283 1997/1998 CODES. CONTROL AREA 3: B/F1/S1 OCCUPANCY CONDITIONS BASED ON THE USE and STORAGE OF HEALTH HAZARD MATERIALS. Liquids: Transfer from </=20-liter .vessels into storage vessels. Solids: Transfer of </=10 pounds Into storage vessels. Building is protected throughout by an automatic fire sprinkler system. -.. USE OPEN Liquid Gins 1.3473 174.7504 279.1250 42.2676 23.1151 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 7 0 ·---··· - Gas Cf .... ~--.. L .. l . i --·"--v--. ~ 'fr--; 1·-n -~~ ··· --i TT"l ;f-Tt 't ··a·n q ·-···-g --.. , '· HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E -UFC/CFC TABLE 8001.15-B SUMMARY -HEALTH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3 TOTAL Carcinogens [SOUDSJ AGGREGATE TOTAL Carcinogens [SOLIDS]: TOTAL Carcinogens (LIQUIDS} AGGREGATE TOTAL Carcinogens [LIQUIDS]: UNLIMITED l~q;,;.w:.'"'g rcm1w1 i~A\!~,; ~~n-f-W-4~' 0.0884 Lbs 19.9784 POUNDS 10.2664 Gins .1.1§fil GALLONS CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE 8001.15-B: 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS: UNLIMITED • WITH SPECIAL CONTROLS lf~".t.n:i;jyesi~~'./t'"\'l,i,';'"'·"4;:1,:'i :'.X 1'.J:7 :~"?'.M,.:;7;~-;,~.~~f,-f,~ ,'z ,;:,;rt ~~, ~h..-.,:~ :c~ i,.~;-;;,.,.,,2~~ ... .:¾-·;.';t/'l~r>l? /_:kl\''.·f,,,\¢,f.-:$...~,)!\~v~~)"'~;~':¢t:;?.-~~ ~t TOTAL Corrosives [SOLIDS] AGGREGATE TOTAL Corrosives [SOLIDS]: TOTAL Corrosives (LIQUIDS] AGGREGATE TOTAL Corrosives (LIQUIDS]: ( :ce .. :,.¥fl,,;: (''§~tri?i.i~I 10.8533 lbs 10.8533 POUNDS 186.9709 Gins 362.2496 GALLONS 1997 UBC TABLE 3·E/UFC TABLE 8001.15-B EXEMPT AMOUNTS PER CONTROLAREA-H-7 OCCUPANCY REQURIED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT· NO CABINETS: 10,000 POUNDS+ 1,000 GALLONS & 1,620 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 20,000 POUNDS+ 2,000 GALLONS & 3,240 CUBIC FEET USE CLOSED EXEMPT AMOUNT: 10,000 POUNDS + 1,000 GALLONS & 1,620 CUBIC FEET USE OPEN EXEMPT AMOUNT: 2,000 POUNDS+ 200 GALLONS @f.('':ttit'l®t l~''-"i~I ,~e~--"-~,, ~ 0.0000 Lbs 0.0000 Gins ;~,!~:A~n~ ~Jl ,t' l~TJ,}Qifflf fftn~1 0.0000 Lbs 0.5283 Gins 1997 UFC 8001.14 RETAIIJWHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 19,500 POUNDS+ 1,950 GALLONS 1999 UFC SUPPLEMENT· RETAIL/WHOLESALE STORAGE/DISPLAY· EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 20,000 POUNDS+ 2,000 GALLONS 1999 UFC CUPPLEMENT • S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 20,000 POUNDS+ 2,000 GALLONS CONTROL AREA 3: B/F1/S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. 19.8900 1.3473 ~~~,1 0.0000 174.7504 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS-ERIKSEN-RATTAN ASSOCIATES INC.· 04/23/2001 • PAGE 8 --- ~ ~ Lbs Gins liVfflil Lbs Gins (ia '. ...... ~ ~--!~~--. I ~-;,.,,. J ... .. r·-·--,.--1 .. Tl~; tJlit rrro .. .. ... .. r-~·-·: HAZARDOUS MATERIALS a_nd OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E -UFC/CFC TABLE 8001.15-B SUMMARY -HEAL TH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3 ffi9~1y;:nim~~i3Y¥~t~t§5_Jf7~il§#!t1if~~+:~~~ I:~~ tWJJt®l TOTAL Highly Toxics [SOLIDS] AGGREGATE TOTAL Highly Toxics [SOLIDS]: TOTAL Highly Toxics (LIQUIDS] AGGREGATE TOTAL Highly Toxics· [LIQUIDS]: 0.7735 0.7735 POUNDS 0.0264 0.0264 GALLONS Lbs Gins 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS PER CONTROL AREA· H-7 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS. STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 20 POUNDS+ 2 GALLONS & 0 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: 40 POUNDS+ 4 GALLONS & 40 CUBIC FEET < f!iOO 0.0000 Lbs 0.0000 Gins USE CLOSED EXEMPT AMOUNT: 20 POUNDS+ 2 GALLONS & 40 CUBIC FEET [CAB/EXHAUSTED ENCL REQD] USE OPEN EXEMPT AMOUNT: ' 6 POUNDS+ 0.6 GALLON 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 39 POUNDS+ 3.9 GALLONS 1999 UFC SUPPLEMENT-RETAIL/WHOLESALE STORAGE/DISPLAY -EXEMPT AMUNTS PER MIS OCCUPANCY CONTROL AREA: 40 POUNDS+ 4 GALLONS 1999 UFC SUPPLEMENT -S OCCUPANCY STORAGE WITH 8001.14 STORAGE CONDITIONS: 40 POUNDS+ 4 GALLONS mimtt~~hJ1~~~t~~~'~*~f&~~~Sl,J,~~~} lliffi:tfa ~ ~ lir1dd?lf tiPMf4\J ·$l!r...,,~,,it'.~ . , __ ,.. . TOTAL Irritants [SOLIDS) AGGREGATE TOTAL Irritants (SOLIDS): TOTAL Irritants (LIQUIDS] AGGREGATE TOTAL Irritants [LIQUIDS]: CONSUMER PRODUCTS -1997 UBC TABlE 3-E/UFC TABLE 8001.15-B: 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS: STORAGE/AGGREGATE EXEMPT AMOUNT: USE CLOSED EXEMPT AMOUNT: USE OPEN EXEMPT AMOUNT: CONTROL AREA 3: B/F1/S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. !-JNLIMITED UNLIMITED UNLIMITED 499.8049 519.6949 POUNDS 345.9510 625.0760 . GALLONS UNLIMITED -WITH SPECIAL CONTROLS Liquids: Transfer from </=20-liter vessels into storage vessels. Solid~: Transfer of </=10 pounds Into storage vessels. Lbs 0.0000 Lbs Gins 0.0000 Gins 0.0000 0.0000 BW®ffl 19.8900 279.1250 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 9 .. ... li@I Lbs Gins f:{Pi[~J Lbs Gins ~---~--~--~ \,ililiilla ~ ry---g fiilliiaail --r --t ~ ~ {.aililii} ~ t-lillilllil ~ .. -,_____ .... --~: ---· ' ,s ' --.. ~-~ ~----~ i:lliiiaill ~~ HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS UBC/CBC TABLE 3-E -UFC/CFC TABLE 8001.15-B SUMMARY -HEALTH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -·control Area 3 0tneH1ea1ffi;,u:ii-'a ·-~i~~~~~'~,;1f ff~J110;,1:~~;;,~::.lt~t;!{~:~ ,..,,~,,-,1,r.;,.,,-J(«~~~-~-,,,~11-,v,,d .,,.,...,~~." ~r, .. 'i.,t,rn>r ,! ,,,,'(" "\l._ .., ,._ , TOTAL Other Health Hazards [SOLIDS) AGGREGATE TOTAL Other Health Hazards [SOLIDS): TOTAL Other Health Hazards [LIQUIDS) AGGREGATE TOTAL Other Health Hazards [LIQUIDS): CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE 8001.15-B: 1997 UBC TABLE 3-E/UFC TABLE 8001.15-8 EXEMPT AMOUNTS: STORAGE/AGGREGATE EXEMPT AMOUNT: USE CLOSED EXEMPT AMOUNT: USE OPEN EXEMPT AMOUNT: $ensiti~e~r-·f;?f1¥W,"f;t};ff'Jj/''!:ji.~~}-;r,~--·':'riS,;""l!~""¾~I;;,, • --~~·/~ , .~~ll-~?-),-';ijfF.:.i-.:!,~0~-,'t,/iVJ~?'f,:~'J~}~'yt1'fi¼ (l°~;~~?51;,;{1:'l,Jf¾W-R TOTAL Sensitizers [LIQUIDS) AGGREGATE TOTAL Sensitizers [LIQUIDS]: CONSUMER PRODUCTS -1997 UBC TABLE 3-E/UFC TABLE 8001.15-B: 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS: . STORAGE/AGGREGATE EXEMPT AMOUNT: USE CLOSED EXEMPT AMOUNT: USE OPEN EXEMPT AMOUNT: CONTROL AREA 3: B/F1/S1 Occupancy Conditions. Building is protected throughout by an automatic fire sprinkler system. UNLIMITED UNLIMITED UNLIMITED lllWffl' -;~1 r·ffif•&.t ~ Q 'f ~-'J!t~.1 30.6638 Lbs 75.2955 POUNDS 69.4855 Gins 111.7531 GALLONS UNLIMITED -WITH SPECIAL CONTROLS 1($Jgfflh'11 J;ymm UNLIMITED UNLIMITED UNLIMITED 0.6844 0.6844 GALLONS UNLIMITED • WITH SPECIAL CONTROLS Gins Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. ~ . l.t?~JPJ;~ 0.0000 Lbs 44.6317 0.0000 Gins 42.2676 s?J;filIJ~~, :;:~,>!'%¼¥-'= ~ . rtJJ!!~ 0.0000 Gins 0.0000 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 10 i.-(=--.1 ~ . Lbs Gins ~ Gins f -... L-·u··H ·.:. .. ,,., ...... ~ ::-llillila ~ ~ . ~'J ------~---C"l HAZARDOUS MATERIALS and OCCUPANCY CLASSIFICATION ANALYSIS ralllia ~ i',illllliilliiil ~ UBC/CBC TABLE 3-E-UFC/CFC TABLE 8001.15-B SUMMARY -HEALTH HAZARD MATERIALS lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3 \?---~ ;iiliiliilliili-····· 1·· ~ ' _., ,-'iiiaii) &lllallll ~---~ I .. ~<i~ffi! Imm a:.\ t~I l!lAit~ N¥~1 ti!',.-,.,, ) ~ " TOTAL Toxics (SOLIDS} AGGREGATE TOTAL Toxics (SOLIDS}: TOTAL Toxics (LIQUIDS} AGGREGATE TOTAL Toxics !LIQUIDS]: 0.4663 0.4663 POUNDS 28.3326 51.9760 GALLONS Lbs Gins 1997 UBC TABLE 3-E/UFC TABLE 8001.15-B EXEMPT AMOUNTS PER CONTROL AREA -H-7 OCCUPANCY REQUIRED ONLY FOR >EXEMPT AMOUNTS STORAGE/AGGREGATE EXEMPT AMOUNT -NO CABINETS: 1,000 POUNDS+ 100 GALLONS & 1,620 CUBIC FEET STORAGE/AGGREGATE EXEMPT AMOUNT -WITH CABINETS: . 2,000 POUNDS+ 200 GALl,.ONS & 3,240 CUBIC FEET USE CLOSED EXEMPT AMOUNT: 1,000 POUNDS+ 100 GALLONS & 1.620 CUBIC FEET USE OPEN EXEMPT AMOUNT: 250 POUNDS+ 25 GALLONS 0.0000 0.5283 1997 UFC 8001.14 RETAIL/WHOLESALE STORAGE/DISPLAY. EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 1,950 POUNDS+ 195 GALLONS+ 3,160 CF 1999 UFC SUPPLEMENT -RETAILJWHOLESALE STORAGE/DISPLAY· EXEMPT AMOUNTS PER MIS OCCUPANCY CONTROL AREA: 2,000 POUNDS+ 200 GALLONS 1999 UFC SUPPLEMENT-S OCCUPANCY STORAGE WITH UFC 8001.14 STORGE C(?NDITIONS: 2,000 POUNDS+ 200 GALLONS. CONTROL AREA 3: B/F1/S1 Occupancy Conditions. Building Is protected throughout by an automatic fire sprinkler system. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Lbs 0.0000 Gins 23.1151 SUMMARY -HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 1 ·1 .. , .... -, ffflll "' Lbs Gins I I I I I I I ,, I I 1· I I ii ;I ·1 :1. :I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 11 May 2001 [Rev. 1] Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net t·---L...-t.111111 :.:-~---. 2 ·r--~ J( · --iJl ff ,, ~ ~ ::·o··--. "1 sr · LI -:,Jiliaili -: ~ @iiliiiill ~ fffTJ 1'.oiilillliia ~ ~ -·--·----g·· T. r'j "'--. ;_:; f- lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3: Hazardous Materials Inventory j~z;3/,j1;J.l,~f--~;~~[}t0?~'~l,~F~-~~~;!firi;~i:ef~t'-'?J~~~tfYV':o --'!';$~f~1i'dii~~;r~°lJBhf01~uH~ic~bf1~f{f~~iWJ'ii~~,tilfu&1«±~ )'l!!l··--e *' -,"'-'"'.);i:'-""·'¼f·'1-v, ·l'il· . za , ~~._, -i~Jl 5i . -~, s mi'· o -.1-:: , •• ,r,:.,";...,,·O a ,,., .. ,) t.M~,~4~-:r:.; ,, jf,i~~..&:&~A.(.:;~ .... -,:-... t;J{:L~-:~-t-~, ~<;;;i..4t-:r:tr~1,:ftt'Jfi!k~''4,:-w...u.; -"--', • ~~? .. ~.-:~_ ... ~,>t1,.:t,.'o/.ft:«filip:2.~i-'*'t-..... "7~:-~~~~ :,.,.,;.~.4,?s:t};:.~/tf:lff3iT.:r.;.;f:!. j:~,l:;t:~,t,; ,-;.p,::[;.(~;::~~5&Z%1~~*;,.~-:a:~ 67-63--0 L , >/=70 lsopropanol [lsopropyl Alcohol] (2-FL1B, IR 1.0567 Gins 0.0000 Gins 0.0000 Gins y FLV CA3-109/T.C. Room Propanol] [Alcohol] [Alpha 870-25 Sqlder [Existing] Flux] [Omega Meter Test Solution] [425 Thinner) [LD50-0: 5,840 mg/kg; LD50-S: 13,000 mg/kg) [FP: 53oF; BP: 82.5oC) [LEL: 2.5%; U~L: 12%] [HR: H2 F3] 2 72-57-1' L </=50 Trypan Blue [Aqueous Solution] [Cl CA,OHH,P65 0.0264 Gins 0.0000 Gins 0.0000 Gins CA3-109/T.C. Room 23850) [Direct Blue 14] [Niagra Blue 3B) [Existing) [Aqueous Solution) [FP: None) [RTECS# QJ6475000] [HR: H2) 3 64-19-7 L >80 AcelicAcid (Glacial) [BP: 118.10; FP: CL2,CR 0.0000 Gins 0.0000 Gins 19.8130 Gins CLV CA3-118/Bulk 104-109oF] (LEL: 5.4%; UEL: 15%) [pH: Solulion & 119/Clean 2.4) [LD50-0ral: 3,310 mg/kg; LD50-Skln: Room[New] 1,060 mg/kg] [HR: H3 F2 COR) 4 2001-000-153 L 100 Collodlal Blue Staining Reagent [62% CR 0.0000 Gins 0.0000 Gins. 105.6691 Gins CA3-118/Bulk Waler; 8% Phosporic Acid; 30% Solution & 119/Clean Ammonium Sulfate) [pH: 1) [FP: None) Room[New] [HR:H3COR) 5 64-17-5 L >/=70 Ethanol [Ethyl Alcohol) [Reagent Alcohol) FL 1B, IR, OHH 0.0000 Gins 0.0000 Gins 2.6417 Gins FLV CA3-118/Bulk [Molasses Alcohol) (Aromalic Elixir) Solution & 119/Clean [ETOH] (Polyamlde Rinse) [FP:55.GoF; Room[New) BP: 78.32oC) [LEL: 3.3%; UEL: 19%] [FV per Gin: 1630] [HR: H3 F3) 6 2001-000-136 L 100 Gel Drying [25% Reagent Alcohol; 75% FL1C, IR, OHH 0.0000 Gins 0.0000 Gins 39.6259 Gins FLV CA3-118/Bulk Water] [FP: 88oF; BP: >100oF) [HR: H2 Solulion & 119/Clean F3] Room[New) 7 2001-000-146 L 100 IEF Cathode Buffer [93% Water; 1% IR,TX 0.0000 Gins 0.0000 Gins 9.9065 Gins CA3-118/Bulk Sodium Azide/26628-22-8; 6% L-Lyslne Solution & 119/Clean Monohydrale) [pH: 10.2] [FP: None] . Room[New) [L:C50-S: 2,000 mg/kg) [HR: H2) 8 2001-000-145 L 100 IEF Cathode Buffer [94% Water; 1% IR,TX 0.0000 Gins 0.0000 Gins 13.2086 Gins CA3-118/Bulk Sodium Azide/26628-22-8; 3.4% L-Lysine Solution & 119/Clean Monohydrate; 3.4% L-Arglnlne) [pH: 10.3) Room[New) [FP: None) [L:C50-S: 2,000 mg/kg) [HR: H2] --- 9 2001-000-141 L 100 Native TrisGly Running Buffer [88% NH 0.0000 Gins 0.0000 Gins 79.2519 Gins CA3-118/Butk Water; <3% Tris Base; >14% Glycine) Solulion & 119/Clean (pH: 8.5) [FP: None) [HR: OJ Room[New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustlble Liquid Vapor. FLY-Flammable Liquid Vapor. Liquids: Transfer from </=20-llter vessels Into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. BuiJding is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RA TT AN ASSOCIATES INC. -04/23/2001 -PAGE 1 ~--I_..,., ~, L..lllil g-····· -,-·t ,-: tr, .. ,,. nr .. -: 0r·--: --~T'UE rt ~,-··· ~ ~--:rr ~,., :-: lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: Hazardous Materials Inventory 'f , .. ,!, · {'jj(_$#,"""' ;,· :;;'!".!f: ls"' .. ,.,."'~"''rf o/J:'~Ml~iflff"". · ',·, '._.,. ~;{~· :;:;~,:i:1r4;·z;\:~ -::+:.,li.. ". :,-~. ,1c iut"'''~'~" { · ~iT:%' ·431 -,~~ ''""'"!j,."'""'""""''·~ '·(l:;-~,E) ' .,~--w~'"'""';:,.t'P"'-' ~"'·····-,;;··-~,,c; .. ~~ro·•1·.l re•·•rt•'''i\'''·-~~rr.t"''.S)'.'i>>·;,;/,''""""'""'"'"ST''.1""~--,Pl"'tT'"""" =m , ~!IJ!~1:;\}S~;-~,:1!~i{f~:J};\x;!t ~\t~;~t-l~:,,c~~i~~~ ~;t~t;~~~~7-X}ii1:~:§~;i~J~'.f ~t:ts•i~!mt~~~ ¼r;ft1,~ii'<£1~~!}~ bt~v h~~~n;. ~A~ti¢~J~:~(::.:t ~ 10 . 2001-000-147 L 100 NuPage Antioxidant [75% Water; 18% CR 0.0000 Gins 0.0000 Gins 13.6049 Sodium Bisulfate; 9% Dimelhylfonnamide: <1% ETDA] [pH: 2] [HR: H3 Cor) ' ' 11 2001-000-151 L 100 NuPage LOS Sample Buffer[8% Water; NH 0.0000 Gins 0.0000 Gins 5.9439 40% Glycerol; 32% Triclne Gel Buffer; <2% EOTA, Lithium Oodecyl Suflate & Phenol Red] (pH: 7.2] [Flash Point None] [HR:O] 12 2001-000-149 L 100 NuPage MES SOS Running Buffer (53% NH 0.0000 Gins 0.0000 Gins 158.5037 Water; 20% MES; 12% Tris Base; 15% SDS; <1% EDTA & NuPage Antioxidant] [pH: 5-6] [Ff:>: None] [HR: OJ 13 2001-000-148 L 100 NuPage MOPS SOS Running Buffer NH 0.0000 Gins 0.0000 Gins 158.5037 (53% Water; 20% MOPS; 12% Tris Base; 15% SDS; <1% EOTA & NuPage Antioxidant] [pH: 5-6] (FP: None] [HR: O] 14 2001-000-150 L 100 NuPage Transfer Buffer (83% Water; 8% NH 0.0000 Gins 0.0000 Gins 79.2519 Bicine; 10% Bis Tris; <1% EOTA & Ghlorobutanol] [pH: 7.2] [FP: None] [HR: OJ 15 2001-000-152 L 100 Simply Blue Safe Stain [94.5% Water; CL3B,IR 0.0000 Gins 0.0000 ,Gins 105.6691 2% Citric Acid; 5% EthanoU64-17-5] [pH: 2.1] [FP: >200oF] [HR: F1 H2] 16 2001-000-138 L 100 Tricine SDS Running Buffer [>68% IR 0.0000 Gins 0.0000 Gins 79.2519 Water; 12% Tris Base, 18% Tricine; >10% Sodium Dodecyl Sulfate] [FP: None] [pH: 8.25] [HR: H1] 17 2001-000-142 L 100 TrisGly SDS Running Buffer [>78% NH 0.0000 Gins 0.0000 Gins 158.5037 Water; 3% Tris Base; 14.5% Glycine; 10.3% Sodium Dodecyl Sulfate] (pH: 8.6) [FP: None] [HR: OJ 18 2001-000-143 L 100 TrisGly Transfer Buffer [85.3% Water; NH 0.0000 Gins 0.0000 Gins 79.2519 3.67% Tris Base; 18% Glycine] (pH: 8.6) [FP: None] (HR: OJ [Jf& t ..... Gins Gins Gins Gins Gins Gins Gins Gins Gins ~r· -~--~ CA3-118/Bulk ~T Solution & 119/Clean Room[New] CA3-118/Bulk Solution & 119/Clean Room[New] CA3-118/Bulk Solution & 119/Clean Room[New] CA3-118/Bulk Solution & 119/Clean Room[New] CA3-118/Bulk Solutlon & 119/Clean Room[New] CA3-118/Buik Solution & 119/Clean Room[New] CA3-118/Bulk Solution & 119/Clean Room[New] CA3-118/Buik Solution & 119/Clean Room(New] CA3-118/Bulk Solution & 119/Clean Room[New] LEV: Local or general/area exhaust ventilation required for Class I, II ~nd Ill-A Liquids use-open conditions. CLV-Combustlble Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-llter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 2 ·-lJalll :_-ii '··-~ ~ . •,;! ~ r§-~ fl - lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: ~"l?~t·rrvi!l':J' ,, ,,J-.,,1,i,,.;, '-o ' ,_ • tetr-f'c-.:< ,,~:,:,:s1 ~5~,~~~/4:~~ i~r1:J,tt~ 19 2001-000-140 L 100 Zymograni Developing Buffer (84% NH Water; <1% Calcium Chloride; 11.7% Sodium Chloride; 6% Tris Base; 7.3% 6N HCL; 0.1% Brij-35) (FP: None] [pH: 7.5] (HR:0) 20 2001-000-139 L 100 Zymogram Renaturing Buffer (27% IR Water; 75% Triton X-100/9002-93-1) [FP: >200oF) [HR: H1) 21 2001-000-137 L 100 Gel Clear [84% Acetic Acid/64-19-7; 16% CL3A,CR Water] [FP: >140bF) [HR: H3 F2] 22 2001-000-144 L 100 IEF Anode Buffer (4% Water; 96% CR Phosphoric Acid/7664-38-2] [pH: 1.1) [FP: None) (HR: H3 COR) 23 64-19-7 L >80 -Acetic Acid (Glacial) (BP: 118.10; FP: CL2,CR 104-109oFJ (LEL: 5.4%; UEL: 15%] [pH: 2.4] (LD50-0ral: 3,310 mg/kg; LD50-Skin: 1,060 mg/kg] (HR: H3 F2 COR] 24 4787-93-3 ·S 100 Acid Red 8 [Cl 14900] [HR: H1J IR 25 631-61-8* L </=90 Ammonium Acetate (Aqueous Solution] IR (Ammonia Acetate Soil Extractant Concentrate] [HR: H2] 26 7783-20-2 s 100 Ammonium Sulfate [Viking Ship NH Ammonium Sulfate 21-0-0] [HR: OJ 27 7440-37-1 CG 100 Argon (Ar] (aw: 39.94] (9.7 cf/lb] (HR: OJ NH 28 150-25-4 s 100 Bicine [N,N-Bis(2-Hydroxyethyl)Glycine] CR [Protein Assay Kit-Bicinchonic Acid] (HR:H3COR] 29 6976-37-0 s 10D Bis(Hydroxymethyl)-2,2' ,2"-IR,OHH Nilrilolriethanol (2,2-) [Bis-Tris] [Bls(2- Hydroxyethyl) lminotris (Hydroxymethyl} Methane] (HR: H2] r,') ··-[?. -~ :,, __ ~ -. ~ ~ Hazardous Materials Inventory 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.8920 Gins 0.0000 Gins 0.0309 Lbs 0.0000 Lbs 0.0053 Gins 0.0000 Gins 0.6630 Lbs 0.0000 Lbs 1344.0000 Cf 0.0000 Cf 10.3870 Lbs 0.0000 Lbs 30.0560 Lbs 0.000D Lbs ~-~ ~ 26.4173 Gins 26.4173 Gins 19.8130 Gins 1~.8504 Gins 0.0000 Gins y 0.0000 Lbs 0.0000 Gins 0.0000 Lbs 0.0000 Cf 0.0000 Lbs 0.000D Lbs fl L CLV. ~-~ CA3-118/Bulk ,j-__ ~ Solution & 119/Clean Room[New] CA3-118/Bulk Solution & 119/Clean Room(New) CA3-119/10K Clean Room(New] CA3-119/10K Clean Room(New) CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room(New) CA3- 121/Manufacturing Room(New) CA3- 121/Manufacturing Room(New] CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room(New) CA3- 121/Manufacturing Room[New) LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-llter vessels into storage vessels. Solids: Transfer of </=10 pounds Into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 3 L-~ ~; 2-lill f;") £ %-I fi--f'L t;: ~y-; -'tt -~-'.slJf <T-~ ~ lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: Hazardous Materials Inventory 30 10043-35-3 s 100 Boric Acid (RTECS# ED4550000J (HR: IR 2.0553 lbs 0.0000 lbs 0.0000 Lbs CA3- H1J 121/Manufacturing Room[New] 31 115-39-9 s 100 Bromophenol Blue NH 0.0221 lbs 0.0000 Lbs 0.0000 Lbs CA3- [3',3"5' ,5"Tetrabromophenolsulfonephthal 121/Manufacturing eln] (RTECS# SJ745300J (HR: OJ Room[NewJ 32 71-36-3 L 100 Butanol (1-) [Butyl Alcohol] [MPA 1075J FL1C, IR · 0.5838 Gins 0.0000 Gins 0.0000 Gins y FLV CA3- [MPA 1075] [FP: 95oF; BP: 244oF] [SG: 121/Manufacturing 0.81; VD: 2.6; VP: 7) [LFL: l4; UFL: Room[New] 11.2]lFV per Gin: 2410 cf] [HR: H2 F3] 33 10043-52-4 s 100 Calcium Chloride [RTECS# EV9800000) IR 0.4641 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [HR:H2] 121/Manufacturing Room[New] 34 10043-52-4 s 100 Calcium Chloride [RTECS# EV9800000) IR 7.0720 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [HR:H2) 121/Manufacturing Room[New) 35 4800-94-6 s 100 Carbenicillin Disodlum Salt (a-IR,OHH 0.0111 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Carboxybenzylpencillin) (Pyopene) [HR: 121/Manufacluring H1] Room[New] 36 65072-00-6 s 100 Casein [Enzymatic Hydrolysate Casein] NH 4.8620 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [Z-Amine A Milk Protein] [HR: OJ 121/Manufacturing Room(New] 37 67-66-3 L 100 Chlorofonn [rrichloromethane) [LD50-CA, IR, OHH, P65, 0.0793 Gins 0.0000 Gins 0.0000 Gins CA3- Oral: 908 mg/kg] [MP: -630; BP: 61oC; RMP-T1, RMP-T3 121/Manufacturing FP: None] [HR: H3) Room[New] · 38 67-66-3 L 100 Chlorofonn [rrichloromelhane] [LD50-CA, IR, OHH, P65, 0.1321 Gins 0.0000 Gins 0.0000 Gins CA3- Oral: 908 mg/kg] [MP: -630; BP: 61oC; RMP-T1, RMP-T3 121/Manufacluring FP: None] [HR: H3] Room[New] 39 5949-29-1 s 100 Citric Acid Monohydrale (HR: H1J IR 192.2700 Lbs 0.0000 Lbs 0.0000 Lbs CA3- 121/Manufacluring Room[NewJ 40 548-62-9* L 50 Crystal Violet [Methyl Violet] [Gentian FL 18, IR, OHH 0.0264 Gins 0.0000 Gins 0.0000 Gins y FLV CA3- Violet] [11% MelhanoU64-17-5J [LD50-0: 121/Manufaciuring 840 mg/kg] [HR: H2 F3J Room(NewJ LEV: L.ocal or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLY-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. · · HAZARDO\IS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 • PAGE 4 ::aa L11i1 411a ;t -· r·'· 1 "i"---· ~~---·-tt-·r· if·rr tT .. );iiiliiiiia ~ r1r--: _w. ;r r :r --1 %'.... r(.---~ . ·: ~ ~ ~ --~-& lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: Hazardous Materials Inventory . ':,,1;,~""1f~,t.:::{::~;"". ~·""'':!*ft'~Gf½~·-:;;~~1:J)//.1;.1;·fr::,\:%0ff':".'¾i.·~?,m'i'l',~1:1-.• ~-irt.;~~~'fjJ~~:lit'iJt r!·"foo'..l~filil~ ;;t,t"~~1K.·'{,fl~·~~:: . 1~tf"·1¥r·1~ ,·· ~;; ~m~£1?.~di;d~t~f2fil~~;~~~i~MMI~iffi.\i~~~~}£:'J~~1 i;t'. -~~,~:(~ .. ·r1t!~ ,~·.kt,-r;.f ~~W..~4!>~'.i,ii!;~~\~~IL~1l\:, ~l:.Z~l~.£!~.'~ 41 68-12-2 L 100 Dimethylfonnamide (N,N-) [DM~J [pH: 8) CA,CL2,IR 1.5089 Gins 0.0000 Gins 0.0000 Gins y CLV CA3- [FP: 126oF; BP: 153oF) [RTECS# 121/Manufacturing LQ2100000] [HR:H3 F2] Room[New] 42 68-12-2 L 100 Dimethylfonnamide (N,N-) [DMF] [pH: 8) CA,CL2,IR 0.0000 Gins 0.0000 Gins 1.3473 Gins y CLV CA3- (FP: 126oF; BP: 153oF) [RTECS# 121/f\1anufacluring LQ2100000] [HR: H3 F2] Room[New] 43 2044-56-6 s 100 Dodecyl Sulfate Lithium Sall [Dodecyl lR 45.3050 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Lithium Sulfate] [Lithium Dodecyl Sulfate] 121/Manufacluring [Laury! Sulfate] [Lithium Laury! Sulfate] Room[New] [LOS) [MP: 79oC] [HR: H2] 44 60-00-4 s 100 EDTA [Ethylened!aminetetraacetic Acid] IR 2.0443 Lbs 0.0000 Lbs 0.0000 Lbs CA3- . [EDTA Free Acid] [ACS Reagent] (MP: 121/Manufacluring 2500) (RTECS# AH4025000] [HR: H1] Room[New] 45 64-17-5 L >/=70 Ethanol [Ethyl Alcohol] [Reagent Alcohol) FL1B, IR, OHH 1.7779 Gins 0.0000 Gins 0.0000 Gins y FLV CA3- [Molasses Alcohol) [Aromatic Elixir] 121/Manufacturing [ETOH] [Polyamide Rinse] (FP:55.6oF; BP: 78.32oC] [LEL: 3.3%; UEL: 19%] [FV Room[New] per Gin: 1630] [HR: H3 F3] 46 64-17-5 L >/=70 Ethanol [Ethyl Alcohol) [Reagent Alcohol] FL1 B, IR, OHH 9.7744 Gins 0.0000 Gins 0.0000 Gins y FLV CA3- [Molasses Alcohol! [Aromatic Elixir] 121/Manufacturing [ETOH] [Polyamide Rinse] [FP:55.6oF; Room(New] BP: 78.32oCJ [LEL: 3.3%; UEL: 19%] [FV per Gin: 1630) [HR: H3 F3] 47 64-17-5 . L >/=70 Ethanol [Ethyl Alcohoq [Reagent Alcohol] FL 1 B, IR, OHH 5.2835 Gins 0.0000 Gins 0.0000 Gins y FLV CA3- [Molasses Alcohol] [Aromatic Elixir] 121/Manofacturing [ETOH] [Polyam!de Rinse] [FP:55.6oF; Room[New] BP: 78.32oC] [LEL: 3.3%; UEL: 19%] [FV per Gin: 1630] [HR: H3 F3] 48 1239-45-8 s 100 Ethidium Bromide [Homidium Bromide! IR,OHH 0.0221 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [MP: 260oj [RTECS# SF7950000] [HR: 121/Manufacturing H2J Room[New] 49 50-00-0* L 10-40 Formaldehyde (Formalin] [Cuposil YJ [10-CA, CL3B, IR, 0.0925 Gins 0.0000 Gins 0.0000 Gins CA3- 40% Solution in Water] (Cuposil Y] OHH, TX, PSM, 121/Manufacturing [Formalex] [pH: 6-6.5] [BP: 212oF; FP: P65, RMP-T1, Room[New] >200oFJ (LD50-0: 1250 mg/kg; LD50-S: RMP-T3 675 rng/kgJ [HR: H3] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 5 i . . -1-,-. _,_ .... · ----r.,:i1ilillia (!,ttiiiiiia e::iliiiiiiilll ,-'f.__.. ?.<imia ·-r-• ---?Jrl ~--T-~ .. --.----~---·-·7 -d--··-~--T'"g ,;:· --. ·::-·T · '._..... ~ ~ llialll ~ ~ ~ ~ ~ ~ :-:~ ~ .. ~ ff.. ·ff eJ ~i-if! lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3: Hazardous Materials Inventory ¥,~,>,/ "r"......,>V-/:'',('5<Y"Y"'1/'~l'<'lo-";:,~~.1%i!. cy;;.2w(~t:'•~ "-~~-a-.a~.;;;.,../r.:<-1:JZ9;-~wcr·i",;-r...,~z-;q),'..;-:,):-f*»-~.r.:,t.:.1;.;ffif>,t¥.zr~w,:v";!';"'"% .... R,~l~~ Ci ,-w ~":1t1ii·. ,:-A:\:i/-.:·.,<.re·>.:.,"' .1',:~>;;Y!,';r~X-'-,:u~ "' '.'if":~~\. c-~1 cf' -. ' tiff tit'Os:"~I ~~J~Jf~~ ~ Jj)~i~ty{ti?Yi1~if~~i~it~Ji~i,, ~, !.~ii¥1~ilz~ n1f,{~JX~ :_~·ffl\l~,lji:;/4:~:.lt~!:!'it::~ 50 75-12-7 L 100 Fonnamide (BP: 210oC; FP: 310oF] Ct3B, IR, OHH 0.1981 Gins 0.0000 Gins 0.0000 Gins CA3- (RTECS# LQ0525000] (HR: H2 F1] 121/Manufacturing Room(New) 51 64-18-6 L 100 Fannie Acid (BP: 1000; FP: 156oF] (LD50-CL3A, CR 0.7661 Gins 0.0000 Gins 0.0000 Gins y CLV CA3- O: 1,076 mg/kg; LC50: 15,000 ppm) (pH: 121/Manufacturing 2] (RTECS# LQ4900000] [HR: H3 F2 Room(New] COR) 52 111-30-8 L 50 Glutaric Dialdehyde [Microbiocide] CR,SN 0.6340 Gins 0.0000 Gins 0.0000 Gins CA3- [Trident 7420] (1,5-Pentanedlal] 121/Manufacturing [Glutaraldehyde] (Cidex] (Omnicide 28) Room[New] (NALCO 2838] [25-50% Solution in Water] (BP: 212oF; FP: None] [pH: 4.1][HR: H3 COR] 53 56-81-5 L 100 Glycerin [GlyceroQ [1,2,3-Propan!3triol] CL3B, IR, OHH 3.0908 Gins 0.0000 Gins 0.0000 Gins CA3-. [Laemmuli Sample Buffer] [FP: 320oF; 121/Manuracturing BP: 1820] [HR: H1 F1] Room[New] 54 56-40-6 s 100 Glycine [AminoaceticAcid] [L-Glycine] NH 8.3980 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [RTECS# MB7600000] [HR: OJ 121/Manufacturing Room[New] 55 7440-59-7 CG 100 Helium [He] (aw: 4.00] (96.71 crnb] [HR: NH 488.0000 Cf 0.0000 Cf 0.0000 Cf CA3- 0) 121/Manufacturing Room[New] 56 7647-01-0 L >/=50-100 Hydrogen Chloride [Hydrochloric Acid] CR, PSM, RMP-T1 11.0688 Gins 0.0000 Gins 0.0000 Gins CA3- [Muriatic Acid] [50-100%] [HCI] [Acid] [pH: 121/Manufacturing <1] [L050-0: 900 mg/kg; LC50: 3,124 . Room[New) ppm] [HR: H3 COR] 57 10025-77-1 s 100 lron(III) Chloride Hexahy_drate [Ferric CR,TX 0.0243 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Chloride Hexahydrate] [MP: 303Q] [L050-121/Manufacturing 0: 450 mg/kg] (DOT Label 8] [RTECS# Room[New] N052525000] [HR: H3 CORI 58 367-93-1 s 100 lsopropyl-b-0-Thiogalactopyranoside CA,IR,OHH 0.0884 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [IPTG] [MP: 120oC; FP: >230oF] [HR: H2] 121/Manufacturing Room(New] 59 55965-84-9 L 100 Kathori LX Biocide [FP: None] [HR: H3 CR 0.1012 Gins 0.0000 Gins 0.0000 Gins CA3- CORI 121/Manufacturing Room[New) LEV: Local or general/area exhaust ventilation required for Class I, II and ·111-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels into storage vessel~. Solids: Transfer of </=10 pounds Into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 6 , -' --, . ---, . . ---··,:---<g' , .. , it.... ¼~ ~----;;,.._. ~ rr-· . ,:----,-&....-"'---.--. ·-'if-{~ , __ ~ ::..... ~ :illll ~----~ ~ ~ ~ ~ ~ =-~ ~ ~ )1:I I ~ ~ lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: Hazar(Jous Materials Inventory 7;:t fllj ~ 7791-18-6 s 100 Magnesium Chloride Hexahydrate [LD50-IR 4.4200 Lbs · 0.0000 Lbs 0.0000 Lbs CA3- 0: 8100 mg/kg] (RTECS# OM2975000] 121/Manufacturing (HR:H1) Room[New) 61 13446-34-9 s 100 Manganese(II) Chloride Tetrahydrate IR,OHH 0.4862 Lbs 0.0000 Lbs · 0.0000 Lbs CA3- (Manganese Chelazome) (LD50-0: 1484 121/Manufacturing mg/kg) [RTECS# 009625000) [HR: H2) Room[New] 62 18598-63-5 s 100 Mecysteine Hydrochloride (Zeotin) [MP: OHH 0.0000 Lbs 0.0000 Lbs 22.1000 Lbs CA3- 14op) [LD50-0ral: 30 g/kg) (HR: H1) 121/Manufacturing Room[New) 63 60-24-2 L 100 Mercaptoethanol (2-) (2-CL3A,HT,IR 0.0264 Gins 0.0000 Gins 0.0000 Gins y CLV CA3- Hydroxyethylm'ercaptan] [FP: 165oF; BP: 121/Manufacturing 157oF) (LD50-0ral: 244 mg/kg; LOSO-Room[New) Skin: 150 mg/kg) [HR: H4 F2] 64 145224-94-8 s 100 MES Monohydrate [4-IR 7.7350 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Morpholineethanesulfonic Acid) [MP: 121/Manufacturing >300oF] [HR: H1] Room(New) 65 67-56-1 L >/=50 Methyl Alcohol [Methanol) [Wood Sealer] FL1B,IR 1.2152 Gins 0.0000 Gins 0.0000 Gins y FLV CA3- [Pen Fix) [Reagent Alcohol) [Blue Blox) 121/Manufacturing (FP: 52oF; BP: 64.7oC/148oF] (LEL: 6%; Room[New) UEL: 36.5%] [Autoignition: 878oF] [Vapor Pressure: 100mm @21.2oCJ [FV per Gin: 1270) [HR: H2 F3) 66 67-56-1 L >/=50 Methyl Alcohol [Methanol) [Wood Sealer] FL1B, IR 0.0000 Gins 0.0000 Gins 1.0567 Gins y FLV CA3- (Pen Fix] [Reagent Alcohol] [Blue Blox) 121/Manufacturing [FP: 52oF; BP: 64.7oC/14BoF] (LEL: 6%; Room[New) UEL: 36.5%) [Autoignition: 878oF) [Vapor Pressure: 100mm @21.2oC][FV per Gin: 1270) [HR: H2 F3) 67 99-000-631 CG 100 Mixed Gas [Argon + Helium or Argon + NH 264.0000 Cf 0.0000 Cf 0.0000 Cf CA3- Neon) [Argomix) [HR: OJ 121/Manufacturing Room(New) 68 1132-61-2 s 100 MOPS (4-Morpholino-Propanesulfonic IR 105.1960 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Acid) [MP: 277oC) (RTECS# 121/Manufacturing QE91045330] (HR: H1) Room[New] 69 7791-20-0 s 100 Nickel(II) Chloride Hexahydrate [RTECS# CA, IR, OHH, P65 0.0000 Lbs 0.0000 Lbs 19.8900 Lbs CA3- QR6475000) [HR: H2) 121/Manufacturing Room[New) LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RA TT AN ASSOCIATES INC. • 04/23/2001 • PAGE 7 ;__.. Lall ~ 71 , -JIii :;a·-1 ~--lliu--. ~s -. ~--GIIIII o· a -:'.•-• ffn·n r1 lB &:d ·1 ~-a n lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: Hazardous Materials Inventory !f,8/F~lG'alfl)~.JZ:'i-i ~t~;;j1\W~?~:;1}ll iwmrtt~;:'ii1'-"f::::fi~~bftjft;~t,j~1$-4~~ ?2,5,.~c -._ ~lli,;tS1.;-iJft~r:1:i,Jt;;,,f.;"'tJ~ri;f:0f' · ~t:'--l..: !l21-'.'¥.,iL,,;~~~f.i~--__ ,¾,_.,k:,t;;:.w~Ji-;1,;zli:· 70 00-01-608 ·L 100 Penicillin-Streptomycin Sulfate Soluffon IR,OHH,SN 0.0264 Gins 0.0000 Gins 0.0000 Gins CA3- [FP: None] [HR: H2] 121/Manufacturing Room[New] 71 143-74-8 s 100 Phenol Red [RTECS# SJ7490000] [HR: IR 0.1127 Lbs 0.0000 Lbs 0.0000 Lbs CA3- H2] 121/Manufacturing Room[New] 72 7664-38-2* L >50 Phosphoric Acid [H3P04] [Porteln Assay] CR 3.1172 Gins . 0.0000 Gins 0.0000 Gins CA3- [BP: 232oF] [Acid-Inorganic] [LD50-0: 121/Manufacturing >4,400 mg/kg; LD50-S: >3,260 mg/kg] Room[New] [pH: 1.5) [RTECS# TB6300000] [HR: H3 COR] 73 9003-11-6* L 100 Polyether Diol [Pluronic] [Polyethylene-CL3B 0.1321 . Gins 0.0000 Gins 0.0000 Gins CA3- Polypropylene Glycol Pluronic] [Pluronic 121/Manufacturing F] [Poypro Block Polymer) [Macol 1] Room[New] [Macol 4] [Macol 43] [Poloxyalkylene Glycol] [Poly-G) [FP: >300oF; BP: >250of; SG: 1.05) [HR: F1) 74 25322-68-3** s 100 Polyethylene Glycol [PEG) [Poly(E!hylene IR 16.7960 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Oxide)) [Carbowax] [Polyox] [Pluracol P-121/Manufacturing 410) [HR: H1) Room[New) 75 2001-000-154 s 100 Ponasterone A [Analog of Ecydsome] IR 1.1050 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [lnvitrogen H101-01; H101-03] [HR: H1] 121/Manufacturing Room[New] 76 127-08-2 s 100 Potassium Acetate [Acetic Acid, IR 0.2652 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Potassium Salt] [RTEDS# AJ3325000) 121/Manufacturing [HR:H2] Room[New] 77 584-08-7 s 100 Potassium Carbonate [MP: 891 oC) IR 16.7960 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [RTECS# TS7750000] [HR: H2] 121/Manufacturing Room[New) 78 1310-58-3 s >/=85 Potassium Hydroxide [Caustic Potash] CR,TX,WR2 0.4420 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [Caustic-Base] [LOSO-Oral: 365 mg/kg] 121/Manufacturing [KOH] [RTECS# TT2100000] [pH: 12] Room[New) [HR: H3 R2 COR WR] 79 26628-22-8 s 100 Sodium Azide [Nondetonatable) [LD50-HT, UR3, WR2, 0.7735 Lbs 0.0000 Lbs 0.0000 Lbs y CA3- Oral: 27 mg/kg; LD50-Skin: 20 mg/kg) RMP-T3 121/Manufacturing [HR: H4 R3 WR] Room[New] -----· · LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLY-Combustible Liquid Vapor. FLV~Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels Into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 8 ,_-__ ~:... l;911 ..... (.·1' .: rw•• ,:.! ;··· cl,,. I ?---~ 0·1 ----, .~~ ,, .• ---·· f.-~. '.¥:······· ~, 1/.-lfliiiliiill ~ ,---.• ?11-··; lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Control Area 3: Hazardous Materials Inventory 80 7631-90-5* L </=50 So_dium Bisulfite [Sodium Hydrogen IR 0.7397 Gins · 0.0000 Gins Sulfite) [NALCO 2548) [Aqueous Solution) [FP: None] [ph: 3.5-4.5) [HR: H2) 81 7647-14-5 s 100 · Sodium Chloride [Salt) [Normal Saline] IR 73.5930 Lbs 0.0000 Lbs [Isotonic Salt] [RTCS# VZ4725000] [HR: H1] 82 68915-3'1-1 s 100 Sodium Hexametaphosphate [Sodium IR 4.4200 Lbs 0.0000 Lbs Hexametaphosphate] (Base] [HR: H1] 83 13472-36-1 s 100 Sodium Pyrophosphate Oecahydrate IR 1.1050 Lbs 0.0000 Lbs [RTECS# UX7350000] [HR: H2] 84 13472-36-1 s 100 Sodium Pyrophosphate Oecahydrate IR 1.9006 Lbs 0.0000 Lbs [RTECS# UX7350000] [HR: H2] 85 7757-83-7 s 100 Sodium Sulfite [LD50-0: >2,825 mg/kg] IR 0.0022 Lbs 0.0000 Lbs [RTECS# WE2150000] [HR: H1] 86 6001-64-5 s 100 Trichloro-2-Methyl-2-Propanol Hydrate IR 0.0884 Lbs 0.0000 Lbs (1, 1, 1-} [Chlorobutanol] [HR: H1] 87 5704-04-1 s 100 Tricine [Tris(Hydroxymethyl)Methyl IR 14.3650 Lbs 0.0000 Lbs Glycine] [pH 7.6-8.8] [HR: H1] 88 9002-93-1 L 100 Triton X-100 [Octylphenoxypolyethanol) CL3B, IR 0.4755 Gins 0.0000 Gins [Octoxynol 40) [FP: >550oF] [pH: 6-8] [L050-0: 1,800 mg/kg] [HR: H2 F1] 89 77-86-1 s 100 Trizma Base [THAM] IR 12.8180 Lbs 0.0000 Lbs [Tris(Hydroxymethyl}Aminomethane] [2- Amino-2-(Hydroxymethyl)-1,3- Propanediol) [TRIS] [Tromethane] [HR: H1] 90 1185-53-1 s 100 Trizma Hydrochloride IR 1.1050 Lbs 0.0000 Lbs [Tris(Hydroxymelhyl} Aminomethane Hydrochloride] [TRIS-HCL] [Tris Hydrochloride] [HR: H2] 01···· fiiliiiiiia ·~ 0.0000 Gins 0.0000 Lbs 0.0000 Lbs 0.0000 Lbs 0.0000 'Lbs 0.0000 Lbs 0.0000 Lbs 0.0000 Lbs 0.0000 Gins 0.0000 Lbs . 0.0000 Lbs :1· --, t- CA3- e{--~ 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustlble Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-llter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 9 ---.----- ~--Lillll ~-*iii --.-~. ~-,-.. ,-. "·1r··1 :~,---, ·f•• "1··-·• f-T ··1 ri--ur1 s,-------rr1r1 nrrn ··1··-·-·1 ~1··--·1 r1 ·: 1 e,-illiliiiila ... lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: Hazardous Materials Inventory v-.r&#;k~,7~~.;jii;p,1;,i.,,tj ,%~~'1tr~o¥ 1,.. 8$,;$_,.., "''~_:_J . Q Fif!!Jt _.;,, -~. ,c: .. ~--··,~}!, ~?ftr_,Q,i.J,!_4',,"J<,{,{":,;.;,n '"i%'4' ~-,Jt.,.,4/-..~'<,j~-~Z!"" ..,i;1'"'l~f~3!'t't'...::'!! 91 9005-64-5 L 100 Tween 20 [Polyoxyelhylene (20) Sorbitan CL3B, IR 0.6340 Gins 0.0000 Gins 0.0000 Gins· CA3- Monolaurate] [FP: >200oF] [HR: F1 H1] 121/Manufacturing Room[New] 92 2650-17-1 s 100 Xylene Cyanole FF [Acid Blue] [Cl 42135] FS, IR 0.0332 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [MP: 295oC] [HR: H2 F2] 121/Manufacturing Room[New] 93 2001-000-156 s 100 Zeocin [Cayla ZEOCL0001, 0005] OHH 0.0000 Lbs 0.0000 Lbs 2.6417 Lbs CA3- [Phleomycin 01/Bleomycln Antibiotic] 121/Manufacturing [Aqueous Solution] [FP: None] [HR: H1] Room[New] 94 2001-000-153 L 100 Collodial Blue Staining Reagent (62% CR 105.6691 Gins 0.0000 Gins 0.0000 Gins CA3-125/Shipping & Water; 8% Phosparic Acid; 30% Receiving [New & Ammonium Sulfate] (pH: 1] (FP: None] Existing] (HR:H3COR] 95 2001-000-137 L 100 Gel Clear (84% Acetic Acid/64-19-7; 16% CL3A,CR 19.8130 Gins 0.0000 Gins 0.0000 Gins CA3-125/Shlpping & Water] [FP: >140oF)lHR: H3 F2] Receiving (New & Existing] 96 2001-000-136 L 100 Gel Drying (25% Reagent Alcohol; 75% FL 1C, IR, OHH 39.6259 Gins 0.0000 Gins 0.0000 Gins CA3-125/Shipping & Water] [FP: 88oF; BP: >100oF] [HR: H2 Receiving [New & F3] Existing] 97 2001-000-144 L 100 IEF Anode Buffer (4% Water; 96% CR 15.8504 Gins 0.0000 Gins 0.0000 Gins CA3-125/Shipping & PhosphoricAcid/7664-38-2] (pH: 1.1] [FP: Receiving [New & None] [HR: H3 COR] Existing] 98 2001-000-146 L 100 IEF Cathode Buffer (93% Water; 1 % IR,TX 9.9065 Gins 0.0000 Gins 0.0000 Gins CA3-125/Shipping & Sodium Azlde/26628-22-8; 6% L-Lysine Receiving (New & Monohydrate] [pH: 10.2] [FP: None] Existing] [L:C50-S: 2,000 mg/kg] [HR: H2] 99 2001-000-145 L 100 IEF Cathode Buffer[94% Water; 1% IR,TX 13.2086 Gins 0.0000 Gins 0.0000 Gins CA3-125/Shipping & Sodium Azide/26628-22-8; 3.4% L-Lysine Receiving [New & Monohydrate; 3.4% L-Arginine] [pH: 10.3] Existing] [FP: None] [L:C50-S: 2,000 mg/kg] [HR: H2] 100 2001-000-141 L 100 Native TrisGly Running Buffer [88% NH 79.2519 Gins 0.0000 Gins 0.0000 Gins CA3-125/Shipping & Water; <3% Tris Base; >14% Glycine] Receiving [New & [pH: 8.5] [f P: None] [HR: OJ Existing] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=1 O pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC.· 04/23/2001 -PAGE 10 '·-.a .a ''.~1-ia ;:1··,·11 .. 'Jr-1 ,. ifi __ , __ .. .• , . ¥£····· -.. lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: Hazardous Materials Inventory 't_).,.,p h¢,0'cc:.i,1,~l"'"'"i,:i#J;,,:•:-) : 'S#~,-r,,+}7;;,f,f -· e:S~ ~J, ,;<-r,::,U,/"'t,;.r;_,/;,,_'~-"-¥ .. "<.I-~~ ,,, /.~k 'I.' ''t'<-.. ~ ..... :..a.,. _;f',l!:•~.. ~ ' , 101 2001-000-147 L 100 NuPage Antioxidant (75% Water; 18% CR 13.6049 Gins 0.0000 Gins Sodium Bisulfate; 9% Dimethylformamlde; <1% ETDA] [pH: 2] [HR:H3 Cor] 102 2001-000-151 L 100 NuPage LDS Sample Buffer [8% Water; NH 5.9439 Gins 0.0000 Gins 40% Glycerol; 32% Triclne Gel Buffer; <2% EDTA, Lithium Dodecyl Suflate & Phenol Red] [pH: 7.2) [Flash Point: None] [HR: OJ 103 2001-000-149 L 100 NuPage MES SDS Running Buffer[53% NH 158.5037 Gins 0.0000 Gins Water; 20% MES; 12% Tris Base; 15% SDS; <1% EDTA & NuPage Antioxidant) [pH: 5-6) [FP: None] [HR: OJ 104 2001-000-148 L 100 NuPage MOPS SDS Running Buffer NH 158.5037 Gins 0.0000 Gins [53% Water; 20% MOPS; 12% Tris Base; 15% SDS; <1% EDTA & NuPage Antioxidant] [pH: 5-6) [FP: None) [HR: OJ 105 2001-000-150 L 100 NuPage Transfer Buffer [83% Water; 8% NH 79.2519 Gins 0.0000 Gins Bicine; 10%BisTris; <1%EDTA&: Chlorobutanol) [pH: 7.2) [FP: None) [HR: OJ 106 2001-000-152 L 100 Simply Blue Safe Slain [94.5% Water; CL3B,IR 105.6691 Gins 0.0000 Gins 2% Citric Acid; 5% ElhanoU64-17-5) [pH: 2.1][FP: >200oF] [HR: F1 H2) . 107 2001-000-138 L 100 Tricine SDS Running Buffer (>68% IR 79.2519 Gins 0.0000 Gins Water; 12% Tris Base, 18% Tricine; >10% Sodium Dodecyl Sulfate] [FP:' None) [pH: 8.25] [HR: H1] 108 2001-000-142 L 100 TrisGly SDS Running Buffer[> 78% NH 158.5037 Gins 0.0000 Gins Water; 3% Tris Base; 14.5% Glycine; 10.3% Sodium Dodecyl Sulfate] [pH: 8.6) [FP: None) [HR: OJ 109 2001-000-143 L 100 TrisGly Transfer Buffer [85.3% Water; NH 79.2519 Gins 0.0000 Gins 3.67% Tris Base; 18% Glycine] [pH: 8.6) [FP: None} [HR: OJ ---------- 1illliiiiiill .... "----~ 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins 0.0000 Gins i-~1-· ...• f .... I T·--·1 CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipplng & Receiving [New & Existing] CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing] CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shlpping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing) LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RA TT AN ASSOCIATES INC. -04/23/2001 -PAGE 11 ,. .. :-----~ --.. '.:alll ... -;.--· . .. G-,;:; ;;--. ~ ~ ~ '0-ti ~ -11---, ~----~ !/-~ ;;---~ ------· !;. f--~ -.. ' lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: Hazardous Materials Inventory 110 2001-000-140 L 100 Zymogram Developing Buffer [84% NH 26.4173 Gins 0.0000. · Gins 0.0000 . Gins CA3-125/Shipping & Water; <1% Calcium Chloride; 11.7% Receiving [New & Sodium Chloride; 6% Tris Base; 7.3% 6N Existing) HCL; 0.1% Brij-35) [FP: None) [pH: 7.5) [HR: OJ 111 2001-000-139 L 100 Zymogram Renaturing Buffer [27% IR 26.4173 Gins 0.0000 Gins 0.0000 Gins CA3-125/Shipping & Water; 75% Triton X-100/9002-93-1) [FP: Receiving [New & >200oF] [HR: H1] Existing] 112 1336-21-6 L >50 Ammonium Hydroxide [Aqua Ammonia] CR.TX 0.0000 Gins 0.5283 Gins 0.0000 Gins CA3- [NH40H] [pH >13) [Base] [LD50-0ral: 137/Fermentation 350 mg/kg) (HR: H3 CORJ [New] 113 5949-29-1 s 100 Citric Acid Monohydrate [HR: H1) IR 3.3150 Lbs 0.0000 Lbs 0.0000 Lbs CA3-138/Custom Services Production Lab[New] 114 67-68-5 · L 100 Dimethyl Sulfoxide [DMSO] [Methyl . CL3B,IR,SN 0.0240 Gins 0.0000 Gins 0.0000 Gins CA3-138/Custom Sulfoxide] [RiboGreen-Component B Services Production (PicoGreen-Component A] (PicoGreen] Lab[New] [FP: 203oF; BP: 3720F] (LD50-0: 14,500 mg/kg] [RTECS# PV6210000) [HR: H2 F1] 115 68-12-2 L 100 Oimethylformamide (N,N-) [DMF] [pH: 8] CA,CL2,IR 0.1321 Gins 0.0000 Gins 0.0000 Gins y CLV CA3-13B/Custom !FP: 126oF; BP: 153oF] (RTECS# Services Productlon LQ2100000] (HR: H3 F2} Lab[New] 116 56-81-5 L 100 Glycerin (GlyceroQ (1,2,3-Propanetriol) CL3B, IR, OHH 1.0567 Gins 0.0000 Gins 0.0000 Gins CA3-138/Custom (Laemmuli Sample Buffer} (FP: 320oF; Services Production BP: 1820] [HR: H1 F1) Lab[New) 117 2650-17-1 s 100 Xylene Cyanole FF [Acid Blue] [Cl 42135] FS, IR 0.0332 Lbs 0.0000 Lbs 0.0000 Lbs CA3-138/Custom [MP: 295oC) [HR: H2 F2} Services Production Lab(New) 118 75-05-8 L >/=50 Acetonitrile [Amidite Diluent] [FP: 42oF; FL1B, IR 39.0976 Gins · 0.0000 Gins 0.0000 Gins y FLV CA3-154/DNA BP: 81oF) [LEL: 3; UEL: 16) [HR: H2 f3] Synthesis [ExlsUng) 119 616-17-7 L 100 Cap B Solution [Gap B Solution Mix) [1-CR, FL1B 3.1701 Gins 0.0000 Gins 0.0000 Gins y FLV CA3-154/DNA Methylimidazole/616-47-7; Synthesis [Existing] Tetrahydrofuran/109-99-9; Pyridine/110- 86-1] [FP: 1oF; BP: 133oF] (LEL: 2.6%; UEL: 12.8%] [HR: H3 F3 COR] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLY-Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels Into storage vessels. Solids: Transfer of </=10 pounds into storage vessels. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCJATES INC.· 04/23/2001 -PAGE 12 , __ _ :----"" --;,,;---~ ~ ~ tial'•' ? il'llliila ~ ... ;······ -.,., ,. ·r1·· - lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Control Area 3: Hazardous Materials Inventory --~ ~~ .. ·-· , .. f.- ils¥f~,it~:Jti1;.i~~;,~9'tr~o/l¾f:Mit~ftiJ;,:;:sittI;,~t1~~;,;:i)tatYiI!ftKJ';;J ··~i.tiis~;%t-:,,~_.mm· 'imif ·· :;'tll~i~~~ffiif'~m:lffl:!lnitit;;(g,~~~J.jses1r~lfi~%t-ii:.ll:ffllB~~ ~t.z;;~0-.:'.;i.7:.r1i~~k'-!~J.r;;;F:.~~-: ~~~~;,;~~~~~~~:,~~:111)-;:flki-~,~;;~~"tt~i-~~:.~'.-¼125~~:.t'fil~~~:t:1: ¥ci,£1\zii~S:~1f~\N'.--4:f 7/tl Y.-:'~/,:2~ ttt. ; :t. ~: ~,._,,*, bJ~~~E:JtJi~.~,.i~:-tt&~~~~~~~§+J.:tVt~~-~4'~~,.a;~~~ 1 ;:.~ 120 2001-000-19 L 100 Oeblock Solution [50% Methylene CA, CR, OHH, TX, 5.1250 Gins 0.0000 Gins 0.0000 Gins CA3-154/DNA Chloridell5-09-2; 50% Dichloroa<;etic P65 Synthesis [Existing) Acid/79-43-6) (LC50: >5,000 ppmj LD50- S: 1,111 mg/kg] [FP: None)(HR: 1:13COR] 121 75-09-2 L >/=70 Dichloromethane [Methylene Chlqride) CA, CR, OHH, P65 3.1701 Gins 0.0000 Gins 0.0000 Gins CA3-154/DNA [Methane Dichloride) [Freon 30] [BP: Synthesis [Exisfing] 104oF; FP: None] [HR: H3 COR) 122 2001-000-20 L 100 Oxidizer Solution [0.2M Iodine Solution In FL1B, IR 1.8228 Gins 0.0000 Gins 0.0000 Gins FLV CA3-154/DNA Telrhydrofuran/109-99-9, Pyridine/110-86-Synthesis [Existing] 1) [HR: H2 F3) 123 2001-000-130 L 100 Solvent Mixture [Acetic Anhydride/108-24-CR, FL 1B, WR1 3.9890 Gins 0.0000 Gins 0.0000 Gins y FLV CA3-154/DNA 7; Pyridine/110-86-1; Synthesis [Existing} Tetrahydrofuran/109-99-9) (HR: H3 F3 R1 COR] 124 288-94-8* L .10 Tetrazole (1-H-) [10% in Acetonitrilell.5-FL1B, IR,-UR2 3.0116 Gins 0.0000 Gins 0.0000 Gins y FLV CA3-154/DNA 05-8] [HR: H2 F2 R2) Synthesis [Existing} LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Liquids: Transfer from </=20-liter vessels into storage vessels. Solids: Tra~sfer of </=10 pounds into storage vessels. Building Is protected throughout by an automatic fire sprinkler system~ HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 13 . 'Jl" I Ii ll I 11 I I I -11 j -I.- I ,, I II I .. , I I I INVITROGEN CORPORATION: 1600 Faraday Avenue, C·arlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California . Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net '..tllil [1111 :_. :-.-r l ·• ,-,-·, :r~;.--, T--·--1_ ... c .... rj,,,~I; .. ~w--,,. Tl-ft WWl ":ff'~l 1fi'1 lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory 1 2001-000-132 l 100 Residual/Waste Halogenated liquids CA, CR, OHH, P65 30.0000 Gins 0.0000 Gins 1.0000 Gins [Dichloromethane/75-09-2, Trichloroacetic Acid/76-03-9] 2 2001-000-133 l 100 Residual/Waste Nickel Chloride/Silver CA,CR,OHH, 30.0000 Gins 0.0000 Gins 1.0000 Gins Nitrate liquids [Nickel Chloride/7791-20-OX1,P65 O; Silver Nitrate/7761-88-8; Solvenls] [FP: None 3 2001-000-131 l 100 Residual/Waste Non-Halogenated High Fl1B, IR 60.0000 Gins 0.0000 Gins 1.0_000 Gins BTU liquids [Acetonilrile/75-05-8, Tetrahydrofuran/109-99-9, Pyridine/110- 86-1, et al] [HR: H2 F3] 4 2001-000-135 s 100 Residual/Waste Non-RCRA D,y Waste CA,IR,OHH 300.0000 lbs 0.0000 lbs 1.0000 lbs [Solids contaminated with Phenol/108-95- 2, Chloroform/67-66-3, Elhidium Bromide/1239-45-8, et al] [HR:H2] 5 2001-000-134 l 100 Residual/Waste Organic Low BTU CR,Fl1B,OHH 30.0000 Gins 0.0000 Gins ·1.0000 Gins Solvents [EthanoU64-17-5, Melhanol/67- 56-1, AcetfcAcld/64-19-7, etal] [HR: H3 . F3] 6 64-19-7 L >80 Acetic Acid (Glacial) [BP: 118.10; FP: CL2,CR 17.4618 Gins 0.0000 Gins 0.0000 Gins y 104-109oF] [LEL: 5.4%; UEL: 15%] [pH: 2.4] [LD50-0ral: 3,310 mg/kg; LD50-Skin: 1,060 mg/kg] [HR: H3 F2 COR] 7 108-24-7 L 100 -Acetic Anhydride [Acetic Oxide] [Acetyl CL2,CR, WR1 5.0000 Gins 0.0000 Gins 0.0000 Gins y Oxide] [MP:-730; BP: 1380; FP: 130oF] [HR: H3 F2 R1 COR] 8 75-05-8 L >/=50 Acetonllrile [Amidite Diluent] [FP: 42oF; FL1B, IR 3.1791 Gins 0.0000 Gins 0.0000 Gins y BP: 81oF] [LEL: 3; UEL: 16] [HR: H2 F3] 9 9031-72-5 s 100 Alcohol Dehydrogenase [HR: H1] SN 4.0000 Lbs 0.0000 Lbs 0.0000 Lbs 10 1336-21-6 L >50 Ammonium Hydroxide [Aqua Ammonia] CR,TX 13.0237 Gins 0.0000 Gins 0.0000 Gins [NH4OH) [pH >13] [Base] [LD50-Oral: 350 mg/kg] [HR: H3 COR] -.,,., ir·=-1 .,,,.,--., CA1-128/Chemical Storage [Existing] CA1-128/Chemical Storage [ExisUng] FlV CA1-128/Chemical Storage [Existing] CA 1-128/Chemical Storage [Existing) FLV CA 1-128/Chemical Storage [Existing] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Sto~ge [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV~Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <1Q% in use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 • PAGE 1 1r~-, .. ~ ... ½--~-.. '1 '"' -' ,' -....... ·:a·r, 1-lliliiiiia ~ f-!'{-_--.---11nt1 ,------·--.g . , .. I ... lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory ·------- c C .-;-·· ., C. f'11(ftYif·i:.,;\ii~~;~tt5~;(it~~j,c;\~\.~~1!;,:~~ii,,lisiffi1rc·ia?umii~lft".itij-bti{i'i~1~tffiim)~;1tfti'if~'iM'f)~'~~~1>'{;?7jl :J.~ h~~::~#.,~~li\?;t/[-;ff-7{fJ:%tH~~if~+::':!fJi~i~:~~, ,~ £ifi ~s(fj~;¾:J;!2~%¼ wf~· ! }~-~Ji :~~ .. JZ; N~--~11;r4t>~*fiG;~'½1,f,t,~,._~,¾{"-:tff?' -:r;.fi';¾.;~~~;&,;__~~:;;~~~21~ ¥~-,1¼¼_.~Jt-zt~?'~;'f~ 11 7727-54-0 s 100 Ammonium Persulfate (Ammonium CR,OX1,SN 6.6300 Lbs 0.0000 Lbs 0.0000 Lbs y CA2-140/Raw Peroxydisulfate] (RTECS# SE0350000] Material Storage [HR: H3 COR OX) [New] 12 7783-20-2* L </=90 Ammonium Sulfate [HR: OJ NH 46.5205 Gins 0.0000 Gins 0.0000 Gins CA2-140/Raw Material Storage [New] 13 74-79-3 s 100 Arginine (L-) [MP: 236oC) [RTECS# NH 100.0000 Lbs Lbs Lbs CA2-140/Raw CF1934200) [HR: OJ Material Storage [New] 14 150-25-4 s 100 Bicine [N,N-Bis(2-Hydroxyethyl)Giycine) CR 10.3870 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw (Protein Assay Kit -Bicinchonic Acid] Material Storage [HR:H3COR] [New] 15 150-25-4 s 100 Bicine [N,N-Bls(2-Hydroxyethyl)Glyclne] CR 198.9000 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw [Protein Assay Kit -Blcinchonlc Acid] Material Storage [HR: H~ COR] . [New] 16 6976-37-0 s 100 Bis(Hydroxymethyl)-2,2' ,'l'-IR,OHH 442.0000 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw Nitrilotriethanol (2,2-) (Bis-Tris] (Bis(2-Material Storage Hydroxyethyl) lminolris (Hydroxymethyl) [New) Methane] [HR: H2] 17 10043-35-3 s 100 Boric Acid [RTECS# ED4550000) (HR: IR 47.5150 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw H1] Material Storage [New] 18 71-36-3 L 100 Butanol (1-) [Butyl A,lcohoq [MPA 1075) FL1C,IR 1.0567 Gins 0.0000 Gins 0.0000 Gins y CA2-140/Raw [MPA 1075] [FP: 9~oF; BP: 244oF] [SG: Material Storage 0.81; VD: 2.6; VP: 7] [LFL: 1.4; UFL: [New) 11.2] [FV per Gin: 2410 cij [HR: H2 F3] 19 75-60-5 s 100 CacodyllcAcld [Hydroxydimethylarslne CA, IR, OHH, P65 0.0442 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw Oxide] [Dlmelhylhydroxyarsine Oxide) Material Storage [LD50-0: 644 mg/kg) [RTECS# [New] CH7525000] [HR: H2] 20 10035-04-8 s 100 Calcium Chloride [Calcium Chloride IR 2.2100 Lbs . 0.0000 Lbs 0.0000 Lbs CA2-140/Raw Dihydrate] [RTECS# EV9800000] [HR: Material Storage H2] [New] . LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS-ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 2 ' .. -;,··-· ,:_--Llllll .. i!--... ~ --k'illiiiiiia ----~ ~ ~--·--l. ~ ... , __ e . <1:Jf I .... 1 .. , ... --~ 0 • YI{\ cliilililiill ~ . ~ f,iliililila ·~ lnvitrogen -1600 Faraday Avenue, Carlsbad CA ~.Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory ~~~'ffi~Arw~:·Y,fj1<}1lM!iJ~~~r-'.2::fa~tfr~Q~~-0i"tiff'.\'f.j~ifl~r~+'J'\1fiJ!~1~~~~;~~ii'11\~\'. "if ~fle',i,J ,n, :•)ii S,E! . 088 -!·· P • $~' ~O • ' 1,l t5':i! 'f,' ' ,if;•Co • a O ' '.~?.'.-.it: t.&~:;'->-l t~'0ii'{J.:i r~t<~,n¼ .~ i;~-~t'fr:li'i?;'?" ·,;:J<~ ~ ~,"1"i:i ~-::~~ :~f£,:~r1,:-;1~ti1~1.~§.;i!<"~·, ,.:~(-'.~t::r,,i:·"':~·Kf? .. :£r }f,t ;lr~-~~¼~ • , /f,, ·'?Ji§;f,\-:L\.-~c$.M ~~~~:13 21 10101-41-4 s 100 Calcium(II) Sulfate Dihydrate [Gypsum]' IR-CP 0.2210 lbs 0.0000 Lbs 0.0000 lbs CA2-140/Raw [Plaster of Paris) [Kellys Gypsum] Material Storage (Recycled Earth Sheetrock) (Agri (New] Gypsum) [Ben Franklin Gypsuml[Soll Buster Gypsun) [HR: H1] 22 616-17-7 L 100 Cap B Solution (Cap 8 Solution Mix) (1-CR, FL18 0.1585 Gins . 0.0000 Gins 0.0000 Gins y CA2-140/Raw Methylimidazole/616-47-7; Material Storage Tetrahydrofuran/109-99-9; Pyridine/110-[New] 86-1) (FP: 1oF; BP: 133oF] (LEl: 2.6%; UEl: 12.8%) [HR: H3 F3 CORI 23 65072-00-6 s 100 Casein (Enzymatic Hydrolysate Casein] NH 22.1000 Lbs 0.0000 lbs 0.0000 lbs CA2-140/Raw (.Z-Amine A Milk Protein) [HR: OJ Material Storage [New) '24 7647-17-8 s 100 Cesium Chloride (MP: 6450) (RTECS# IR 0.2210 lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw FK9625000] [HR: H2) Material Storage [New) 25 57-15-8 s 100 Chlorobulanol (Acetone Chloroform) TX 10.0000 Lbs 0.0000 lbs 0.0000 lbs CA2-140/Raw (1, 1, 1-Tlichloro-2-Methyl-2-Propanol] Material Storage [LD50-0: 213 mg/kg) [RTECS# [New] VC0175000) [HR: H3] 26 67-66-3 L 100 Chloroform [Trichloromethane) [L050-CA, IR, OHH, P65, 0.1321 Gins 0.0000 Gins 0.0000 Gins CA2-140/Raw Oral: 908 mg/kg] [MP: -630; BP: 61oC; RMP-T1, RMP-T3 Material Storage FP: None] (HR: H3) [New) 27 7758-99-8 s 100 Copper(II) Sulfate Pentahydrate [Cupric IR,TX 0.4862 Lbs 0.0000 Lbs 0.0000 Lbs CA2°140/Raw Sulfate Penlahydrate] [LOSO-Oral: 300 Material Storage mg/kg) [RTECS# GL8900000) [HR: H2) (New) 28 57 407--08-6· L 100 OEAE Sepharose [Diethylaminoethyl F~ 18, IR, OHH 1.5850 Gins 0.0000 Gins 0.0000 Gins y CA2-140/Raw Sepharose) (Suspension in 20% Ethanol] Material Storage (HR:H2F1) [New) 29 2001--000-19 l 100 Deblock Solution [50% Methylene CA, CR, OHH, TX, 1.1888 Gins 0.0000 Gins 0.0000 Gins CA2-140/Raw , Chloride/75--09-2; 50% Dichloroacetic P65 Material Storage Acid/79-43-6) (LC50: >5,000 ppm; LOSO-[New] S: 1,111 mg/kg) [FP: None] [HR: H3 COR] 30 79-43-6 L 100 DichloroaceficAcld (BP: 1940; FP: None) CA, CR, OHH, TX, 5.0000 Gins 0.0000 ~Ins 0.0000 Gins CA2-140/Raw [LD50-0: 2820 mg/kg; LD50-S: 510 P65 Material Storage mg/kg) [HR: H3 COR) [New] ----·-· ··------~ LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLY-Combustible Liquid Vapor. FLY-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 3 ll I ;----,__.... -~-.. r~ iiiiailll ~ ~ ~lliiiila. ~\ ,:;tillllaiilil ~ .. r:'llilililai ~ ,,..,,.._ ~...-.. ~ -·:-11f1 ,.. rr1··1 '.<----··· ~ ': < lnvitrogen -1600 Faraday.Avenue, Carlsbad-CA -Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory 3 ~;,,-,ii;'.Oi.!o"S;Z·, !;,?~iJfl ff'~:;:-., 1:-;,;'~:i~;,::!iW·i' ~~';!/~'{t",t_ ,:,. ~-It.,· \~l~ ,:. 'a ·-1~.Q~n".;;;;PMi "·· , tr ut> ~,;-,-,,§¾f)f,;...;:E.,~ :·-1,;L~l~~+fiitti1-&t1~~;, ~~1~iif'fli£:,Jj,;;:x .~,&'&J~,:ctf:lt!f.-1& 31 75-09-2 L >/=70 Dichloromethane [Methylene Chloride] CA, CR, OHH, P65 3.1701 Gins 0.0000. Gins 0.0000 Gins (Methane Dichloride] [Freon 30] [BP: 104oF; FP: None] [HR: H3 COR] 32 1609-47-8 L 100 Oiethytpyrocarbonate {Diethyl CL3A,IR 0.3170 Gins 0.0000 Gins 0.0000 Gins y Oxydiformate] [Diethyl Pyrocarbonate] [DEPC] [DEP] [RTECS# LQ9350000] [BP: 93o/18mm; FP: 157of] [LD5p-O: 850 mg/kg) [HR: H2 F2] --· 33 67-68-5 L 100 Dimethyl Sulfoxide [DMSO) [Methyl CL3B,IR,SN 0.0240 Gins 0.0000 Gins 0.0000 Gins Sulfoxide) [RiboGreen-Component B [PicoGreen-Component A) [PicoGreen) [FP: 203oF; BP: 3720F] [LD50-0: 14,500 mg/kg] [RTECS# PV6210000] [HR: H2 F1] 34 68-12-2 L 100 Dlmethylformamide (N,N-) [DMF] [pH: 8] CA,CL2,IR 4.1554 Gins 0.0000 Gins 0.0000 Gins y [FP: 126oF; BP: 153oF] [RTECS# LQ2100000] [HR: H3 F2] 35 27565-41-9 s· 100 Dithiothreitol [Cleland's ReagenQ [OTT] IR,OHH , 1.3260 Lbs 0.0000 Lbs 0.0000 Lbs [di-OTT] ff hreo-1,4-Olmercapto-2,3- Butanedlol] [OTT] [Luciferase Assay Substrate) [HR: H2) 36 60-Q0-4 s 100 EOTA [Ethylenediaminetetraacetic Acid] IR 27.4040 Lbs 0.0000 Lbs 0.0000 Lbs [EOTA Free Acid) [ACS Reagent) [MP: 2500) [RTECS# AH4025000) [HR: H1) 37 64-17-5 L >/=70 Ethanol [Ethyl Alcohol) [Reagent Alcohol] FL 18, IR, OHH 7.925_2 Gins 0.0000 Gins 0.0000 Gins y (Molasses Alcohol) [Aromatic Elixir) · [ETOH) [Polyamide Rinse] [FP:55.6oF; BP: 78.32oC] [L.EL: 3.3%; UEL: 19%) [FV per Gin: 1630) [HR: H3 F3) 38 64-17-5 L >/=70 Ethanol [Ethyl Alcohol] [Reagent Alcohol) FL 18, IR, OHH 79.2519 Gins 0.0000 Gins 0.0000 Gins y [Molasses Alcohol) [Aromatic Elixir) [ETOH] [Polyamide Rinse] [FP:55.6oF; . BP: 78.32oC) [LEL: 3.3%; UEL: 19%] [FV per Gin: 1630] [HR: H3 F3] 39 64-17-5 L >/=70 Ethanol [Ethyl Alcohol] [Reagent Alcohol] FL18,IR,OHH 19.9979 Gins 0.0000 Gins 0.0000 Gins y (Molasses Alcohol] [Aromatic Elixir] [ETOHJ [Polyamide Rinse] [FP:55.6oF; BP: 78.32oC] [LEL: 3.3%; UEL: 19%] [FV. per Gin: 1630] [HR: H3 F3] ... ···--'•. £-liiiiiilill ~ CA2-140/Raw Material Storage (New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage {New] CA2-140/Raw Material Storage [New) CA2-140/Raw Material Storage [New) CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount = Maximum amount in use and storage, unless otherwise noted. Not all materials are In use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 4 ~-- ~ --....... ,,..._. \:J.!!!!!111111 ~ ~ .. ralll .. ,i_ -t:iJ qt JI,) -. ~-~ : & ,,, lnvitrog~n -1600 Faraday Avenue, Carlsbad CA -Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory ii,\[~~}1r1J~f40<tf;~;-;o/i"?tlti'Fr'f"''f~;sfj;)::;;~l~·~t-;t';,•ifi)J;'.,,~}':~",0f~t~~i'jfti~:~~i~f~~i£§tf'''~ni111!'"ifi'P1f<:r~1~~)?71]'w:-r:~i,f'.~ ,,q,:,,·,i+f· etJ · Qnc 9,'t, e a ill"''·';--/,, ·p1·,l'·.·,,,--,,,-.;,A,.,.-~,"' as :, .. ,,ft ge. n " ~~-· ase .,,, m .}.1 • • • ~ fa·, "'"' a "' ; tJtiJ:~~--.:/4:,/~~-, -:!: {., ~e:~" !\~J' ;!V,;!:f':i,Wst'::r-~7<N''«tke--;~~:J\~J~i~-:~futV;E-:t·:;%>~'"-if.t.. }tt,:.-;*'}/~l~~~!1~fuj,,1:.,~~~-:', ~ /\ fa-:..~-~~ "",t£i.'&--=, s_,.-t N~iix'J!t ,:Al?t~it~NA:,.., ·/ ~1;',$:>;),,V,>¢<\'~¾.~-14?;,. (~\i~:-':/~'',.; w, ,,:...:-:.~--7~;.:z~: 40 2002-24:6 s 100 Elhanolamine Hydrochloride (2-IR,OHH 1.0000 Lbs -0.0000 Lbs 0.0000 Lbs Aminoethanol) [MP: 84oC) (RTECS# KJ6370000) (HR: H2] - 41 107-21-1 L 100 Ethylene Glycol (1,2-Ethanediol) (EG] CL3B, IR, OHH 0.0774 Gins 0.0000 Gins 0.0000 Gins [MACuDizer 9221-S) [MacDermid 19227) (Dowtherm 4000} (Red Devil Onetime Spackllng) (FP: 232oF) [HR: H2 F1). 42 26873-85-8 ·S 100 Ficoll 400 [Nonionic Synthetic Polymer of NH 0.8840 Lbs 0.0000 Lbs 0.0000 Lbs Sucrose) [HR: OJ 43 26873-85-8 s 100 Ficoll 400 (Nonionic Synthetic Polymer of NH 0.0707 Lbs 0.0000 Lbs 0.0000 Lbs Sucrose) [HR: OJ 44 50-00-0• L 10-40 Formaldehyde (Formalin) (Cuposit VJ (10-CA, CL3B, IR, 0.7925 Gins 0.0000 Gins 0.0000 Gins 40% Solution in Water] (Cuposit VJ OHH, TX, PSM, [Formalex] [pH: 6-6.5] (BP: 212oF; FP: P65, RMP-T1, >200oF] [LD50-O: 1250 mg/kg; LD50•S: RMP-T3 675 mg/kg) [HR: H3) 45 75-12-7 L 100 Formamide (BP: 210oC; FP: 310oF] CL3B, IR, OHH 0.6851 Gins 0.0000 Gins 0.0000 Gins (RTECS# LQ0525000] [HR: H2 F1) -..._ 46 111-30-8 L 50 Glutaric Dialdehyde (Microbiocide) CR,SN 30.1421 Gins 0.0000 Gins 0.0000 Gins [Trident 7420) [1,5-Pentanedial] (Glutaraldehyde] (Cidex) (Omniclde 28) [NALCO 2838) (25-50% Solution in Water) (BP: 212oF; FP: None) [pH: 4.11[HR: H3 COR) 47 56-81-5 L · 100 Glycerin [Glycerol) (1,2,3-Propanetriol) CL3B, IR, OHH 29.8515 Gins 0.0000 Gins 0.0000 Gins [Laemmuli Sample Bulfer) [FP: 320oF; BP: 1820] (HR: H1 F1] 48 56-40-6 s 100 Glycine (AminoaceticAcid] [L-Glycine] NH 906.1000 Lbs 0.0000 Lbs 0.0000 Lbs (RTECS# MB7600000] [HR: OJ 49 593-84-0 s 100 Guanidine lsothiocyanate (Guanidine IR 2.2100 Lbs 0.0000 Lbs 0.0000 Lbs Thiocyanate] [MP: 120oC) [RTCS# XL 1225000) [HR: H2) .. .,., ..... . ~ CA2-140/Raw Material Storage (New) CA2-140/Raw Material Storage [New}- CA2-140/Raw Material Storage [New) CA2-140/Raw Material Storage (New) CA2-140/Raw Material Storage [New) CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New) CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% In use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RA TT AN ASSOCIATES INC. -04/23/2001 -PAGE 5 .. ,.., --tllll t .. ._, ..... -~ q----l T-···1 ;, J, .. ----··- r.: ,_, r.: ... . ' . .. ·1· j k .. - . _,_ -;-Mlliliiii ~~ },__ ~-¼-~ .. ;,:illllillllia ~ \ lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory ~i:J§:.'.j!,~,ffili~-~,,6fl1"fcl~~?~1}lt·I:.i':~;i:zs7.~~"1{iz1~·0~ZJ~~ln:-irif~itr~:,,~1Ihi·'ruiiti~~,;~\a· ,;~~~~ ,. .-,:,,-*',··, --~ ci ae ,-,,,,_,,_,,.,,?,f,,"1i-,4-.-i~.Ji!2Ji ,. •:>;;Yjf -·,. 1 A o _,,. ,; . , .!M/!:d:{~1!;;1,'VA..t'-.&!ff;/i;;Y..<.• :tif', ~ -~~d<it~11~2,,;;,~~,:;ti~¾ ~t~~~~ ', -Y"''. 'n--:,t'_.;!Jt!ppy4lS1,\i:!,,t'll¾.~~i 9U$.M~~,t~ff-¼hl>t0~ ~# ,,~-ttft.i-t ·.~~!&B!Jr.~tyr,, ~ 50 50-01-1 s 100 Guanidine Monohydrochloride [Guanldine IR, TX 131.4950 Lbs 0.0000. Lbs 0.0000 ·Lbs CA2-140/Raw Hydrochloride] [MP: 1850] [LD50-0: 475 Material Storage mg/kg) [RTECS# MF4300000] [HR: H3] [New] 51 7365-45-9 s 100 HEPES [4-{2-Hydroxyethyl)-1-IR 2.8730 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw Piperazineethane Sulfonic Acid] [N-2-Material Storage Hydroxyethyipiperazlne-N'-2-[New] Ethanesulfonic Acid] [MP: 2340] [RTECS# TL6809000] [HR: H1] 52 10534-89-1 s 100 Hexaminecobalt(III) Chloride [MP: 2170] IR,OHH 02763 Lbs ·0.0000 Lbs 0.0000 Lbs CA2-140/Raw [HR:H2] Material Storage [New] 53 7647-01-0 L >/=50-100 Hydrogen Chloride [Hydrochloric Acid] CR, PSM, RMP-T1 4.1211 Gins 0.0000 Gins 0.0000 Gins CA2-140/Raw (Muriatic Acid] [50-100%] (HCIJ (Acid] (pH: Material Storage <1] [LD50-0: 900 mg/kg; LC50: 3,124 [New] ppm] [HR: H3 COR) 54 123-31-9 s 100 Hydroquinone (Dihydroxybenzene] IR, OHH, TX, RMP-0.1989 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw (Hydroquinol] [Quinol) [LD50-0ral: 320, T3 Material Storage mg/kg)(HR: H3] [New] 55 5470-11-1 s 100 Hydroxylamine Hydrochloride' (Stabilized] CR, OHH, SN, UR2 0.4420 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw [Reducing Agent, Catalyst] [RTECS# Material Storage NC3765000] [HR: H3 R2 COR] [New] 56 288-32-4 s 100 lmidazole (MP: 89oC; BP: 256oC] [HR: CR 13.2600 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw H3COR] Material Storage [New] 57 305-53-3 s 100 lodoacetic Acid Sodium Salt (HR: H3] IR,TX 0.6188 Lbs 0.0000 Lbs 0.0000 Lbs CA2-140/Raw Material Storage (New] · 58 123-51-3 L 100 lsoamyl Alcohol [Methyl-1-Butanol (3-)] CL2,IR,SN 0.0740 Gins 0.0000 Gins 0.0000 Gins y CA2-140/Raw [lsopentyl Alcohol) (FP: 114oF; BP: Material Storage 130oF) (LEL: 1.2; UEL: 9.0) (HR: H2 F2] [New] 59 67-63-0 L >/=70 lsopropanol [lsopropyl Alcohol) (2-FL1B, IR 7.3968 Gins 0.0000 Gins 0.0000 Gins y CA2-140/Raw Propanol] [Alcohol] (Alpha 870-25 Solder Material Storage Flux] (Omega MeterTestSolution)[425 [New] Thinner) [LD50-0: 5,840 mg/kg; LD50-S: 13,000 mg/kg] [FP: 53oF; BP: 82.5oC) [LEL: 2.5%; UEL: 12%] (HR: H2 F3] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustlble Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building Is protected throughout by an automatic fire sprinkler system. · HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS-ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 6 §-~ :~ "Llill : .. :r I! '.liiiilia ~ ·a·l I ,g;-··· --" ~ ~1lliliilliliii .e-;:iiiliiia ~~-c.... /;,liillililii ~·~ ... 11·r; .... 'r . ~ ~ .. l!lvitrogen -1600 Faraday Avenue, Carlsbad CA -Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory rtiiif~if~rli·JF,~;;,'¥t::rttr;,wl#.r~fJ'wf1lfiJ~"§i;~??z~{l~~¥J54f@f#fcl9,~;1JJ!iJ\tlrif<y:i1 ·,~4tt~»"ftll/r·«fWif'ifi::;~.,,J;=l«,~~Q'i+;ttJ :.--::~·,;; ,, • .:?;,;~ .. J:ti~.:.,~-'."":'lt~\'f>:fl'-:icwWi:;; bf'--;l':1xt0.:\A'.~-'([~J'tt :,;.~:.~\'-');)'s:\1":vs .t,'l.-~~S';1i:{ 'f;1,.;J)Jl,.:\'&\ ~! !w~J:r-::tt •. i,.,..:. ',.;_ ,.;%Jl1:,?l.'!Wx·"~:::l'.-·.~ .. t5&m.'*'~J~ 60 25389-94-0 s 100 Kanamycin Monosulfate [HR: H1] OHH 0.0111 Lbs 0.0000 Lbs 0.0000 Lbs 61 56-87-1 s 100 Lysine (L-) [L-Lysine Monohydrate] [L-NH 100.0000 Lbs 0.0000 Lbs 0.0000 . _Lbs Lysine Hydrate] [2,6-Dfaminohexanoic Acid] [RTECS# OL5540000] [HR: OJ 62 7791-18-6 s 100 Magnesium Chloride Hexahydrate [LD50-IR 7.9560 Lbs 0.0000 Lbs 0.0009 Lbs O: 8100 mg/kg] [RTECS# OM2975000] (HR: H1] 63 10034-99-8 s 100 Magnesium Sulfate Heptahydrate (Epsom NH 1.1713 Lbs 0.0000 Lbs 0.0000 Lbs Salts] [RTECS# OM4508000) [HR: OJ 64 13446-34-9 s 100 Manganese(II) Chloride Tetrahydrate IR,OHH 0.6630 Lbs 0.0000 Lbs 0.0000 Lbs [Manganese Chelazome] [LD50-0: 1484 mg/kg) [RTECS# 009625000] [HR: H2] 65 18598-63-5 s 100 Mecysteine Hydrochloride [Zeotin] [MP: OHH 5.5250 Lbs 0.0000 Lbs 0.0000 Lbs 14op) [LD50-0ral: 30 g/kg] [HR: H1] 66 4420-74-0 L 100 Mertapcopropyltrimethoxysilane CL2,IR, WR1 0.2642 Gins 0.0000 · Gins 0.0000 Gins y [Trimethoxysilyl Propanethiol] [BP: 1980; FP: 120oF] [RTECS# TZ7800000] [HR: H2F2R1] 67 145224-94-8 s 100 !J1ES Monohydrate (4-IR 132.6000 Lbs 0.0000 Lbs 0.0000 Lbs Morpholineethanesulfonic Acid] [MP: >300of) [HR: H1] 68 67-56-1 L >/=50 Methyl Alcohol [Methanol] [Wood Sealer] FL1B, IR 11.6236 Gins 0.0000 Gins 0.0000 Gins y ·(Pen Fix] (Reagent Alcohol] [Blue Blox] [FP: 52oF; BP: 64.7oC/148oF] [LEL: 6%; UEL: 36.5%] [Autoignition: 878oF] [Vapor Pressure: 100mm@21.2oC] [FV per Gin: 1270) [HR: H2 F3] 69 617-04-9 s 100 Methyl-a-D-Mannopyranoside [a-OHH 0.4420 Lbs 0.0000 Lbs 0.0000 Lbs Methylmannoside] [Methyl-a-D- Mannoside] [HR: H1] 70 110-26-9 s 100 Methylene(bis)Acrylamide (N,N'-) (Bis-) IR,TX 53.0400 Lbs 0.0000 Lbs 0.0000 Lbs [Electrophoresis Reagent] [BIS] [HR: H3] I .. ·;--·--i . CA2-140/Raw Material Storage (New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [Newj CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor: FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in ·use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 7 (lliiiiila ~ r~ -, ..... ~~ ;--;:..a,, .... ~~-~~ ... r_ J ?.~ ~ rn~ 1 I .. ~ ·---,.... -·---... --~--.. ,· _., £~ r..: .. ---._ - lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Building ·inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory ~i;;~::.!~t1'1;fdfl~m;~wt~~1trtrf~trtm~;.@.l'~1Jf:ii,"1i;1tr~~J~ ~'U£#!J,· }! ·<'"· .~"' ':~ i'i! -~·',,J! ,f· ,. ~J,.,,,T,ml;,ir:,;:c.rJe · ~IJl~"~R !¾.!"!_,.,_..,,.; £ ._,p, w~,~-,.<;:o., 'l,;,.,,o--vJ.$n,;,.d',,., ,t",..._1' ,t;./h~ ,< -.::~u. if":;;i f.'0•:.W,~ l~ ,« ,,,nc~~ ,\.r4~v~ 71 1132-61-2 s 100 MOPS (4-Morphollno-Propanesulfonic IR 105.1960 Lbs o.oorio Lbs 0.0000 Lbs Acid] [MP: 277oC) (RTECS# QE91045330] [HR: H1] 72 1132-61-2 s 100 MOPS (4-Morpholino-Propanesulfonlc IR 1240.4730 Lbs 0.0000 Lbs 0.0000 Lbs Acid] [MP: 277oC] [RTECS# QE91045330] [HR: H1] 73 7791-20-0 s· 100 Nickel(II) Chloride Hexahydrate (RTECS# CA, IR, OHH, P65 2.2100 Lbs 0.0000 Lbs 0.0000 Lbs QR6475000] [HR: H2] ' 74 2001-000-20 L 100 Oxidizer Solution [0.2M Iodine Solution in FL 18, IR 0.1585 Gins 0.0000 Gins 0.0000 Gins y Tetrhydrofuran/109-99-9, Pyridlne/110-86- 1) [HR: H2 F3] 75 00-01-608 L . 100 Penlclllln-Streptomycin Sulfate Solution IR,OHH,SN 0.0264 Gins 0.0000 Gins 0.0000 Gins [FP: None] [HR: H2] 76 108-95-2 s 100 Phenol [Carbolic Acid] [LD50-0: 317 CR, FS, OHH, TX, 0.4420 Lbs 0.0000 Lbs 0.0000 Lbs mg/kg; LD50-S: 669 mg/kg; lC50: 316 RMP-T3 mg/m3] [HR: H3 F2 COR] 77 15593-04-9 L 100 Phenol Chlorofonn lsoamyl Alcohol [BP: CL38,CR, TX 0.1057 Gins 0.0000 Gins 0.0000 Gins 2290; FP: 240oF] [HR: H3 F1 CR] 78 13822-28-1 L 50 Phenol Red [1,4'-(3H-2, 1-Benoxathiole-NH 5.0000 Gins 0.0000 Gins 0.0000 Gins 3,3-Diyl)Diphenol,S,S-Dioxide] [pH 6.8- 8.2) [FP: None] [HR: OJ 79 7664-38-2* L >50 Phosphoric Acid (H3P04] (Porteln Assay) CR 4.6230 Gins 0.0000 Gins 0.0000 Gins [BP: 232oF) [Acid:lnorganic] (1.050-0: >4,400 mg/kg; LD50-S.: >3,260 mg/kg] [pH: 1.5) [RTECS# TB6300000) [HR: H3 CORI BO 9002-89-5 s 100 Poly(Vinyl Alcohol) [Mowiol 40-88) CD 0.5304 Lbs 0.0000 Lbs 0.0000 Lbs [Gelvatol] [Polyvinyl Alcohol Resin] (RTECS# TR8100000) [PVA} (HR: F2] 81 25322-68-3 .. s 100 Polyethylene Glycol [PEG] (Poly(Ethylene IR 852.3970 Lbs 0.0000 Lbs 0.0000 Lbs Oxide)) [Carbowax) [Polyox] [Pluracol P- 410) [HR: H1] ,--~ ;,:_ ;;:-~ --- CA2-140/Raw Material Storage [New) CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New) CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New) CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New) CA2-140/Raw Material Storage [New] CA2-140/Raw Material Storage [New] LEV: Local or general/area exhaust ventilation required for Class I, II' and 111-A'Liqulds use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are In use at the same time, with <10% In use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS-ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 8 ~--. ~ .~ .... ·Ja111~r·· • I ;. ;-.ji••• v.-.. ,----r:rcr a ~ "Cf. ~ ~ o··-----, l·-·u ,;_ ~J'il f;; rn-1 ... --rTu ~..---n .. ;¥----~ lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Building Inventory [Control Areas 1, 2, 3]: ~azardous Material~ Inventory 152 2001-000-144 l 100 IEF Anode Buffer [4% Water; 96% CR 0.0000 Gins 0.0000 Gins 15.8504 Gins PhosphoricAcid/7664-38-2) (pH: 1.1] [FP: None] [HR: H3 COR] 153 64-19-7 l >80 Acetic Acid (Glacial) [BP: 118.10; FP: Cl2,CR 0.8920 Gins 0.0000 Gins 0.0000 Gins y 104-109oF] [LEL: 5.4%; UEl: 15%] [pH: 2.4J [LD50-0ral: 3,310 mg/kg; lD50-Skln: 1,060 mg/kg] [HR: H3 F2 COR] 154 4787-93-3 s 100 Acid Red 8 [Cl 14900] [HR: H1J IR 0.0309 lbs 0.0000 Lbs 0.0000 lbs 155 631-61-8* L </=90 Ammonium Acetate [Aqueous Solution] IR 0.0053 Gins 0.0000 Gins 0.0000 Gins [Ammonia Acetate Soil Extractant Concentrate) [HR: H2) 156 7783-20-2 s 100 Ammonium Sulfate [Viking Ship NH 0.6630 lbs 0.0000 lbs 0.0000 lbs Ammonium Sulfate 21-0-0] [HR: OJ 157 7440-37-1 CG 100 Argon [Ar] [aw: 39.94] [9.7 ctnb] [HR: OJ NH 1344.0000 Cf 0.0000, Cf 0.0000 Cf 158 150-25-4 s 100 Bicine [N,N-Bis(2-Hydroxyethyl)Glycine) CR 10.3870 Lbs 0.0000 Lbs 0.0000 lbs [Protein Assay Kit-Biclnchonlc Acid] [HR:H3CORJ 159 6976-37-0 s 100 Bls(Hydroxymethyl)-2,2' ,'l'-IR,OHH 30.0560 Lbs 0.0000 Lbs 0.0000 Lbs Nilrilotriethanol (2,2-) [Bis-Tris] [Bis(2- Hydroxyethyl) lminotris (Hydroxymethyl) Methane] [HR: H2J 160 10043-35-3 s 100 Boric Acid [RTECS# ED4550000J [HR: IR 2.0553 lbs 0.0000 Lbs 0.0000 Lbs H1) 161 115-39-9 s 100 Bromophenol Blue NH 0.0221 Lbs . 0.0000 Lbs 0.0000 lbs (3' ,3"5' ,5"T elrabromophenolsulfonephthal ein] [RTECS# SJ745300] [HR: O] 162 71-36-3 l 100 Butanol (1-) [Butyl Alcohol) [MPA 1075) Fl1C, IR 0.5838 Gins 0.0000 Gins 0.0000 Gins y [MPA 1075] [FP: 95oF; BP: 244oFJ [SG: 0.81; VD: 2.6; VP: 7] [LFL: 1.4; UFL: 11.2) [FV per Gin: 2410 cl] [HR: H2 F3] ff_ .... , re···, CA3-119/10K Clean Room[New] ClV CA3- 121/Manufacturing Room[New] CA3- 121/Manufacluring Room[New] -- CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[NewJ CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[New] CA3- 121/Manufacluring Room[New] FLV CA3- 121/Manufacturing Room[New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid yapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 16 ~ ... .,_.. ~ :_ .. 'Jlill '~.: -. ·r -_-,::i ,._ .. r•-m --.::: f' ... ~TT t er-J .:w• r;--~11 -;:-f-. c--~,.~ r ~ir ··-1 ~'OiJ fC"'"T 'Jta rr·,-• \ lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory ~nt~,tjf5f);J:;;,1r~Vffcfr1¾·if',,~pjy':'.tr;·)t';,'.i~;t:;?-';,-'t2;;~,,~~~:~.l1i~f,;;-TT);i,,1'f,1JAt"'~Jt'1~1-~~-~.;:;:~if:;,;ll;;;r;:.~~.'.9;?,~~(fk•~¼~>~r"'~~§:'P,f'4'tA"~~~:t'.fliS ~;1:?:\\:t:: ·,. ,~;;:,o -~,.i'fJ·,, ct. .1 ~r{::1\1..fi~-~Jt;:.;J_ .. _~£~;f1ft'r:Ji:·.,{ ~-:-'-,1 ',/ ,f~~itr~~, i',9 •·,,~-~~~ .. .,,.·,~,7, ~. /,. ~·J. ,,· · .. ,$! :s, ..... U:i'.:t1,J1! .,~_; __ .,.JJ;:;,, .. {';, .. J ,,,,, ... ;~,~;;)~~ ,r,V,,1,,.1:~,.'1'~ ';.M',1;:,,,,ruu,,,r,0::··; ,r .• ,.,,,·;.;;;~,.. 11(,.\~.t4'.lf/1J,;~ .i:;?.L,,;;,,J',fl.:'Ji .,,·½-'!':} .,.'L1, ;. ·;,,·~-11'¥/40,e '"" ;.·,; ·• '"" .-,cia:!i i i:f-* · a ""~·'" r-'! .,i,;;),,r,i'§l~,J~_etL~-·· ':s:,·.'1t.;<'j:-.,;•<R't ff"'-~~;.;~~'i!.~ifl:,,,.,1,-;,;,,.; 163 10043-52-4 s 100 . Calcium Chloride [RTECS# EV9800000) lR 0.4641 lbs 0.0000 Lbs 0.0000 Lbs CA3- [HR:H2] 121/Manufacturing Room[New] 164 10043-52-4 s 100 Calcium Chloride [RTECS# EV9800000] IR 7.0720 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [HR:H2] 121/Manulacturing Room[New) 165 4800-94-6 s 100 Carbenicillin Disodium Salt [a-IR,OHH 0.0111 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Carboxybenzylpencillin] [Pyopene] [HR: 121/Manufacturing H1] Room[New] 166 65072--00-6 s 100 Casein [Enzymatic Hydrolysate Ca~ein] · NH 4.8620 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [Z-Amine A Milk Protein] [HR: OJ 121/Manufacturing Room[New] 167 67-66-3 L 100 Chlorofonn [Trichloromelhane] [LOSO-CA, IR, OHH, P65, 0.1321 Gins 0.0000 Gins 0.0000 Gins CA3- Oral: 908 mg/kg] IMP: -630; BP: 61oC; RMP-T1, RMP-T3 121/Manufacturing FP: None] [HR: H3] Room[New] 168 67-66-3 L 100 Chlorofonn [Trichloromelhane) (LOSO-CA, IR, OHH, P65, 0.0793 Gins 0.0000 Gins . 0.0000 Gins CA3- Oral: 908 mg/kg] [MP: -630; BP: 61oC; RMP-T1, RMP-T3 121/Manufacturing. FP: None) [HR: H3] Room[New] 169 5949-29-1 s 100 Citric Acid Monohydrate [HR: H1] IR 192.2700 Lbs 0.0000 Lbs 0.0000 Lbs CA3- 121/Manufacturing Room[New] 170 548-62-9* L 50 Crystal Violet !Methyl Violet] [Gentian FL 18, IR, OHH 0.0264 Gins 0.0000 Gins 0.0000 Gins y FLV CA3- Violet] [11% Methanol/64-17-5) [L050-0: 121/Manufacturlng 840 mg/kg] [HR: H2 F3] Room[New] _ 171 68-12-2 L 100 Dimethylformamide (N,N-) (DMF] [pH: 8) CA,CL2,IR 0.0000 Gins 0.0000 Gins 1.3473 Gins y CLV CA3- [FP: 126oF; BP: 153oFJ [RTECS# 121/Manufacturing LQ2100000] [HR: H3 F2] Room[New] 172 68-12-2 L 100 Dimethylformamide (N,N-) [DMF] [pH: 8) CA,CL2,IR 1.5089 Gins 0.0000 Gins 0.0000 Gins y CLV CA3- [FP: 126oF; BP: 153oF] [RTECS# 121/Manufacturing LQ2100000] [HR: H3 F2) Room[New) 173 2044-56-6 s 100 Dodecyl Sulfate Lithium Sall (Dqdecyl IR 45.3050 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Lithium Sulfate] [Lithium Dodecyl Sulfate] 121/Manufacturing [Laury! Sulfate] [Lithium Laury( Sulfate] Room(New] (LOS] IMP: 79oC] [HR: H2] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLN-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount = Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building Is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES l~C. • 04/23/2001 • PAGE 17 rrr "--.. ~ ..... Uli [ -i(IIII ti -1 1l lJ IE.-a.ilil ~ ~;--~ ~,....a ~ 89111 ~ff ·g ~1 :·~ -·:·wa tR11 rug1 ··; . ~--~11 ·• ... lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Building Inventory [Control Areas 1, 2, 3): Hazardous Materials Inventory ii1;·~-~~~&'1~·~'j!; ~:~"i~w/;£1~~'~icfMYJ1fll'4ffi·1\~{~-e-"!!>~~~~1'<¼ii,' -i,li"';' '·;:"•<;· 11' ·emtf!J,',-~~1tfa11}fwd.b}itlf i\:tt, 7"',M!lf~mf~-~-"!t'~fi''i~fttt"',;!~J$,:1'g~nzrttlt~ ff. ~;;_-¥';,/;:-'," --l r1 [(!: c-'•,M et ~.;:n, ; ~~--:,'f..;,,,,,, ,.,{,:.,,¥-. ,, .. f.,,;:>...._, : ~ $ -~:.,,n .: ( , $ :..:,4 y " n-?t~-!: J "" ---a (+, -$ • , ,,-. ~-Vf _.; ~-JfilJ:::»:.~.~.dk?~~~-1f' ~,~7J;'.;~-iffittt:;.,_...,, ~1£~~r:f111¾it~&., :~h~~ -~~ ~;~:ir.io/~r~~f ~~~~.t, .,!~~~A.aZS0t~i7f P&-~4'.&r~~ltt1¼;~1'gL;:;1.:,}J-~~~~fift·r,!;~t\?:Mle:,-}~~~ 174 60-004 s 100 EDTA [Ethylenediaminetetraacetic Acid) IR 2.0443 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [EDTA Free Acid] [ACS Reagent] [MP: 121/Manufacturing 2500) [RTECS# AH4025000) [HR: H1) Room[New) 175 64-17-5 L >/=70 Ethanol [Ethyl Alcohol) [Reagent Alcohol) FL1B,IR, OHH 5.2835 Gins 0.0000 Gins 0.0000 Gins y FLV CA3- [Molasses Alcohol] [Aromatic Elixir] 121/Manufacturing [ETOH] [Polyamide Rinse] [FP:55.6oF; Room[New] BP: 78.32oC) [LEL: 3.3%; UEL: 19%] [FV per Girt 1630) [HR: H3 F3] 176 64-17-5 L >/=70 Ethanol [Ethyl Alcohol] [Reagent Alcohol) FL 18, IR, OHH 9.7744 Gins 0.0000 Gins 0.0000 Gins-y FLV CA3- [Molasses Alcohol) [Aromatic Elixir] 121/Manufacturing ' [ETOH) [Polyamide Rinse) [FP:55.6oF; Room[New) BP: 78.32oC) [LEL: 3.3%; UEL: 19%) [FV per Gin: 1630) [HR: H3 F3] --- 177 64-17-5 L >/=70 Ethanol [Ethyl Alcohol] [Reagent Alcohol) FL1B, IR,.OHH 1.7779 Gins 0.0000 Gins 0.0000 Gins y FLV CA3- [Molasses Alcohol) [Aromatic Elixir) 121/Manufacturing [ETOH] [Polyamide Rinse] [FP:55.6oF; Room[New] BP: 78:32oC) [LEL: 3.3%; UEL: 19%] [FV per Gin: 1630] [HR: H3 F3] 178 123945-8 s 100 Ethidium Bromide [Homidium Bromide] IR,OHH 0.0221 Lbs 0.0000 Lbs 0.0000 Lbs CA3- [MP: 2600) [RTECS# SF7950000] [HR: 121/Manufacturing H2] Room[New] 179 50-00-0* L 1040 Formaldehyde [Formalin) [Cuposit YJ [10-CA, CL3B, IR, 0.0925 Gins 0.0000 Gins 0.0000 Gins CA3- · 40% Solution in Water] [Cuposit Y] OHH, TX, PSM, 121/Manufacturing [Formalex) [pH: 6-6.5) [BP: 212oF; FP: P65, RMP-T1, Room[New] >200oF) [LD50-0: 1250 mg/kg; L050-S: RMP-T3 675 mg/kg) [HR: H3] 180 75-12-7 L 100 Formamide [BP: 210oC; FP: 310oF] CL3B, IR, OHH 0.1981 Gins 0.0000 Gins 0.0000 Gins CA3- [RTECS# LQ0525000) [HR: H2 F1) . 121/Manufacturing Room[New] ... -. --~ 181 64-18-6 L 100 Formic Acid [BP: 1000; FP: 156oF) [LD50-CL3A, CR 0.7661 Gins 0.0000 Gins 0.0000 Gins y CLV CA3- 0: 1,076 mg/kg; LC50: 15,000 ppm) [pH: 121/Manufacturing 2) [RTECS# LQ4900000] [HR: H3 F2 Room[New) CORI 182 111-30-8 L 50 Glutaric Dialdehyde [Microbiocide] CR,SN 0.6340 Gins 0.0000 Gins 0.0000 Gins CA3- [Trident 7 420) [1,5-Pentanedial] 121/Manufacturing [Glutaraldehyde) [Cidex) [Omnicide 28) Room[New] [NALCO 2838) (25-50% SoluUon in Water) [BP: 212oF; FP: None) [pH: 4.1][HR: H3 COR) ------------· ------·--··· LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 18 ·~--.. :-<'.'.iilllillaaa :...-~ . --.. ·1.c··· r·_ ..... , ~ ~ I··: ·£~ Y.iiiiilililli .._' z...... re-·· ~ ~ "&Tl '· «w·-c ,,llllilliiiill ... % .... -·· r ----~ - lnvitrogen -1600 Faraday Avenue, Carlsbad CA. Building Inventory [Control'Areas 1, 2, 3]: Hazardous Materials Inventory ij;s~~~ft.iitrJ,:,;~'tiii:fl;i~t~ai~~(h·::~:;l.~~:Sc~~1/;?~.~f ~iibr~~tt¾];;1sjt~fd'l<f}i~'7!/0,~,a:r·~,ff.D~''i''·}lJm'r6~sti5if~ij~t'.l~~.:~~i3e'%Zl1i&~ffl~q1 > .. SJ.iJ'-':'+F">•• ·-,-~·,!<~ 'tl ~ ... , .... t(~·"!.f'{;;f:tl,1~:r;:,~,•s,,.t;is:·.,.e . .,, '-~@,_ s;fP,} g~41~--'~ ~-~ ~--., -~ ti;,; §'e•.'.,---J¥,;?J. 1,·,~i .{'-:-fl· .. (•,, .. ;;,.,;q ;,,}<-,Z,'-;,,.,¥ tr._,...::;r:._!J'"4i!.,-3,,7'-:f;,-;!f;,,4.l_'>;...,f';)tw }jJ,;..,i'S,;-,.,,~~ ... ¼i~t'l':if-':,11Y~~~~-$,,-t,,',~-,,l)'fJ)7,/f, -~~,,.,,;;i:r~ hl,/, .:.~-.• , -~{4:-i.?"·t~-Pf~y_, ,~r.,;~-".',; ',' -~ :~-",,..:,?,;i!,fi --~-~ ~ ~ ~0},;;~%'".r·~r!';r;,, ~,tf_..i.,lv,f-h; -~;:J/1.'ffit._.;,~1'-....t~ ,s/f.,*-:;:,.,_,;,,~-1.,A"1>'~:'h. 183 56-81-5 L 100 Glycerin [Glycerol] (1,2,3-Propanelriol] CL3B, IR, OHH 3.090~ Gins 0.0000 Gins 0.0000 Gins CA3- ' (Laemmuli Sample Buffer) [FP: 320oF; 121/Manufaciuring BP: 1820) [HR: H1 F1) Room[New) 184 56-40-6 s 100 -Glycine (AminoaceticAcid] [L-Glycine] NH 8.3980 Lbs 0.0000 Lbs 0.0000 Lbs CA3- (RTECS# MB7600000) [HR: OJ 121/Manufacturing Room[New) 185 7440-59-7 CG 100 Helium (He) (aw: 4.00) [~6.71 cf/lb] (HR: NH 488.0000 Cf 0.0000 Cf 0.0000 Cf CA3· OJ 121/Manufacturing Room[New) 186 7647-01-0 L >/=50-100 Hydrogen Chloride [Hydrochloric Acid] CR, PSM, RMP-T1 · 11.0688 Gins 0.0000 Gins 0.0000 Gins CA3- [Muriatic Acid) (50-100%) [HCI) (Acid] [pH: 121/Manufacturing <1) [LD50-O: 900 mg/kg; LC50: 3,124 • Room{New) ppm) [HR: H3 COR] 187 10025-77-1 s 100 lron(III) Chloride Hexahydrate [Ferric CR,TX 0.0243 Lbs 0.0000 Lbs 0.0000 Lbs CA3- Chloride Hexahydrate} (MP: 3030) [LD50-121/Manufacturing O: 450 mg/kg) [DQT label 8) (RTECS# Room(New) NO52525000) [HR: H3 COR) 188 367-93-1 s 100 lsopropyl-b-0: Thiogalactopyranoside CA,IR,OHH 0.0884 Lbs 0.0000 Lbs 0.0000 Lbs CA3- (IPTG) [MP: 120oC; FP: >230oF) [HR: H2] 121/Manufacturing Room(New) 189 55965-84-9 L 100 Kathan LX Biocide [FP: None) [HR: H3 CR 0.1012 Gins 0.0000 Gins 0.0000 Gins CA3- CORJ 121/Manufacturing Room[New) 190 7791-18-6 s 100 Magnesium Chloride Hexahydrate [LD50· IR 4.4200 Lbs 0.0000 Lbs 0.0000 Lbs CA3- O: 8100 mg/kg] (RTECS# OM2975000) 121/Manufacturing [HR:H1) Room[New) 191 13446-34-9 s 100 Manganese(!!) Chloride Tetrahydrate IR,OHH 0.4862 Lbs 0.0000 Lbs 0.0000 Lbs CA3· [Manganese Chelazome) [LD50-O: 1484 121/Manufacluring mg/kg) [RTECS# 009625000) [HR: H2) Room(New) 192 18598-63-5 s 100 Mecysteine Hydrochloride [Zeolln) (MP: OHH 0.0000 Lbs 0.0000 Lbs 22.1000 Lbs CA3- 14op] [LD50-Oral: 30 g/kg) [HR: H1) 121/Manufacturing Room[New} 193 60-24-2 L 100 Mercaptoethanol (2-) (2· CL3A,HT,IR 0.0264 Gins 0.0000 Gins 0.0000 Gins y CLV CA3- Hydroxyethylmercaptan) [FP: 165oF; BP: 121/Manufacturing 157oF) (LD50-Oral: 244 mg/kg; LD50-Room[New) Skin.: 150 mg/kg) [HR: H4 F2) LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials ·are in use at the same time, with <10% in use at any time. Building is protected throughout by _an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 · PAGE 19 tam JIiii )11111 i,,_ ~ ~--{all .... ----, ·----· e ... ~--., rr· g-·---{'_· ----r.-illlliiiiiil ~ -.. lilvitrogen -1600 Faraday Avenue, Carlsbad CA-Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory 194 145224-94-8 s 100 ' MES Monohydrate (4-IR 7.7350 Lbs . . 0.0000 , Lbs 0.0000 Lbs Morpholineethanesulfonic Acid] (MP: >300oF] [HR: H1] 195 67-56-1 L >/=50 Methyl Alcohol [Melhanoij [Wood Sealer] FL1B,IR 1.2152 Gins 0.0000 Gins 0.0000 Gins y [Pen Fix] [Reagent Alcohol] [Blue Blox] [FP: 52oF; BP: 64.7oC/148oF] (LEL: 6%; UEL: 36.5%] [Autoignition: 878oFJ [Vapor Pressure: 100mm @21.2oCJ [FV per Gin: 1270] [HR: H2 F3] 196 67-56-1 L >/=50 Methyl Alcohol [Melhanoij [Wood Sealer] FL1B, IR 0.0000 Gins 0.0000 Gins 1.0567 Gln!l y [Pen Fix) [Reagent Alcohol] [Blue Blox] ~ [FP: 52oF; BP: 64.7oC/148oF] [LEL: 6%; UEL: 36.5%] (Autoignition: 878oF] [Vapor Pressure: 100mm @21.2oC][FV per Gin: 1270] [HR: H2 F3] 197 99-000-631 CG 100 • Mixed Gas [Argon + Helium or Argon + NH 264.0000 Cf 0.0000 Cf 0.0000 Cf Neon] [Argomix] (HR: OJ 198 1132-61-2 s 100 MOPS [4-Morpholino-Propanesulfonic IR' 105.1960 Lbs 0.0000 Lbs 0.0000 Lbs Acid] (MP: 277oC] (RTECS# QE91045330] [HR: H1] 199 7791-20-0 s 100 Nlckel(II) Chloride Hexahydrate [RTECS# CA, IR, OHH, P65 0.0000 Lbs 0.0000 Lbs 19.8900 Lbs QR6475000) (HR: H2) 200 00-01-608 [. 100 Penicillin-S\feptomycln Sulfate Solution IR,OHH,SN 0.0264 Gins 0.0000 Gins 0.0000 Gins [FP: None) [HR: H2) 201 143-74-8 s 100 Phenol Red (RTECS# SJ7 490000) (HR: IR 0.1127 Lbs 0.0000 Lbs 0.0000 Lbs H2) 202 7664-38-2* L >50 Phosphoric Acid [H3P04] (Portein Assay) CR 3.1172 Gins 0.0000 Gins 0.0000 Gins [BP: 232oF] [Acid-Inorganic] [LD50-0: >4,400 mg/kg; LD50-S: >3,260 mg/kg] (pH: 1.5] [RTECS# TB6300000] [HR: H3 COR] ~ ~ ' --- CA3- 121/Manufacturing Room[New] FLV CA3- 121/Manufacturing Room[New] FLV ·CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] CA3· 121/Manufacturing Room[New) CA3- 121/Manufacluring Room[New) CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount = Maximum amount in use and storage, unless otherwise noted. Not all materials are In use at the same time, with <10% In use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARQOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC.· 04/23/2001 • PAGE 20 ,--·--- ·(1111111 '..11111 ..... .. nc .. w··· -_.. ,. , .... ~ ~----~ 1,---·--z.... f -;{. ,,_ ~ - lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory ·'&t f:J£;!i _.,_, 203 1 9003-11-6* L I 100 Polyether Oiol [Pluronic] [Polyethylene-· CL3B 0.1321 Gins 0.0000 Gins 0.0000 Gins Polypropylene Glycol Pluronic] [Pluronlc Fl [Poypro Block-Polymer] [Maco! 1) (Macol 4) [Macol 43] [Poloxyalkylene Glycol] [Poly-G) [FP: >300oF; BP: >250oF~SG: 1.05] [HR: F1] 204 25322-68-3·· s 100 Polyethylene Glycol [PEG] (Poly(Ethylene JR 16.7960 Lbs 0.0000 Lbs 0.0000 Lbs Oxide)) (Carbowax] [Polyox) (Pluracol P- 410] [HR: H1] 205 2001-000-154 s 100 Ponasterone A [Analog of Ecydsome] JR 1.1050 Lbs 0.0000 Lbs 0.0000 Lbs [lnvilrogen H101-01; H101-03] [HR: H1] 206 127-08-2 s 100 Potassium Acetate [Acetic Acid, IR 0.2652 Lbs 0.0000 Lbs 0.0000 Lbs Potassium Salt] [RTEDS# AJ3325000] [HR:H2) 207 584-08-7 s . 100 Potassium Calbonate [MP: 891oC] JR 16.7960 Lbs 0.0000 Lbs 0.0000 Lbs [RTECS# TS7750000] [HR: H2] I 208 1310-58-3' s >/=85 Potassium Hydroxide (Caustic Potash] CR,TX,WR2 0.4420 Lbs 0.0000 Lbs 0.0000 Lbs [Caustic-Base] [LD50-Oral: 365 mg/kg] [KOH] [RTECS# TT2100000) [pH: 12) (HR: H3 R2 COR WR] 209 26628-22-8 s 100 Sodium Azide [Nondetonatable) [LD50-HT, UR3, WR2, 0.7735 Lbs 0.0000 Lbs 0.0000 Lbs y Oral: 27 mg/kg; LD50-Skin: 20 mg/kg) RMP-T3 (HR: H4 R3 WR) 210 7631-90-5* L </=50 Sodium Bisulfite [Sodium Hydrogen IR 0.7397 Gins 0.0000 Gins 0.0000 Gins Sulfite) [NALCO 2548] [Aqueous Solution) [FP: None] [ph: 3.5-4.5) [HR: H2) 211 7647-14-5 s 100 Sodium Chloride [Salli' (Normal Saline] JR 73.5930 Lbs 0.0000 Lbs 0.0000 Lbs [Isotonic Salt] [RTCS# VZ4725000] (HR: H1] 212 68915-31-1 s 100 Sodium Hexametaphosphate [Sodium IR 4.4200 Lbs 0.0000 Lbs 0.0000 Lbs Hexametaphosphale] [Base] [HR: H1] 213 13472-36-1 s 100 Sodium Pyrophosphate Decahydrate IR 1.1050 Lbs 0.0000 Lbs 0.0000 Lbs [RTECS# UX7350000] (HR: H2] -------·- ·,:-~~ CA3- <;:-~ 121/Manufacturlng Room[New] CA3- 121/Manufacturlng Room[New] CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturlng Room[New] CA3- 121/Manufacluring Room[New] CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturlng Room[New] CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturlng Room[New] CA3- 121/Manufacturing Room[New) LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are In use at the same time, with <10% In use at any time. Building Is protected throu·ghout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 • PAGE 21 . - illillllllla; .... , ....... ~ ~ ._...._ ~-... I ~-: .. ,.., .. ,,.r----'f.;. r, ;·-·--, .. 0J"-·g ;; .. , .... -~ ,::~ ~ ~ -----' ~ f."'T en-· «: ., ... ,, ~ lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory 214 13472-36-1 s 100 Sodium Pyrophosphate Decahydrate IR 1.9006 Lbs 0.0000 Lbs 0.0000 Lbs [RTECS# UX7350000) [HR: H2] ~ I 215 7757-83-7 s 100 Sodium Sulfite [LD50-0: >2,825 mg/kg) IR 0.0022 Lbs 0.0000 Lbs 0.0000 Lbs [RTECS# WE2150000] [HR: H1) 216 6001-64-5 s 100 Trichloro-2-Methyl-2-Propanol Hydrate IR 0.0884 Lbs . 0.0000 Lbs 0.0000 Lbs (1, 1, 1-) [Chlorobutanol] [HR: H1] 217 5704-04-1 s 100 Tricine [f ris(Hydroxymelhyl}Melhyl IR 14.3650 Lbs 0.0000 Lbs 0.0000 Lbs Glycine) [pH 7.6-8.8) [HR: H1) 218 9002-93-1 L 100 Triton X-100 [Octylphenoxypolyelhanol) CL38, IR 0.4755 Gins 0.0000 Gins 0.0000 Gins (Octoxynol 40] [FP: >550oF) [pH: 6-8) [LD50-0: 1,800 mg/kg] [HR: H2 F1] ... 219 77-86-1 s 100 TriZITia Base [fHf\M] IR 12.8180 Lbs 0.0000 Lbs 0.0000 Lbs [f ris(Hydroxymelhyl)Amlnomelhane] [2- Amino-2-(Hydroxymelhyl)-f ,3- Propanediol) (TRIS) [Tromelhane) (HR: H1] 220 1185-53-1 s 100 TriZITia Hydrochloride IR 1.1050 Lbs 0.000,0 Lbs 0.0000 Lbs [f ris(Hydroxymelhyl) Aminomelhane Hydrochloride] [fRIS-HCL] [f ris Hydrochloride) [HR: H2] --- 221 9005-64-5 L 100 Tween 20 [Polyoxyethylene (20) Sorbitan CL3B, IR 0.6340 Gins 0.0000 Gins 0.0000 Gins Monolaurate] [FP: >200oF) [HR: F1 H1) 222 2650-17-1 s 100 Xylene Cyanole FF [Acid Blue) [Cl 42135) FS, IR 0.0332 Lbs 0.0000 Lbs 0.0000 Lbs [MP: 295oC] [HR: H2 F2] 223 2001-000-156 s 100 Zeocin [Cayla ZEOCL0001, 0005) OHH 0.0000 Lbs 0.0000 Lbs 2.6417 Lbs [Phleomycin 01/Bleomycin Antibiotic] [Aqueous Solution] [FP: None) [HR: H1) 224 2001-000-153 L 100 Collodial Blue Staining Reagent [62% CR 105.6691 Gins 0.0000 Gins ·0.0000 Gins Water; 8% Phosporic Acid; 30% Ammonium Sulfate) [pH: 1) [FP: None) [HR:H3COR] -- illliiiiiiill ~ CA3- ,r--·. 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[New) CA3- 121/Manufacturing Room[New] CA3- 121/Manuracturing Room[New) CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] CA3- 121/Manufacturing Room[New] CA3- 121/Manuracturing Room[New] - CA3-125/Shipping & Receiving (New·& Existing) LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system .. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 22 ,--,. ,__ :-:-·-~ :---,., ... ,. ~ ~: ~ ,., .. ,._,----,; -----· t vr1 w r:811 .. -'.:....a. ~ f -; I '.E--t lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory :'£ ~ N,i', .. ,,~,"'! ,,.,. ·,t~-::;' /,_,"<':i':..J.,'lvf,;. #~ (;',; '':::,,,;;,> ·i ;•,A•~,;-,,..,4,:n,,,,...,.,,,,., ,,;," . *,.;,,.,. 'w,.v,-,;r,-,,·1:;,,,. ..... ,A,', 'I:', (',-4,.X--~:r,,;,n•;;.:., -~~ ¥, t,.,...;-;,• ; -wy~-~«.;:,·.,.,-,-,··;•w·~·-;,;-r,-·i,.·,-v-.. 225 2001-000-137 L 100 Gel Clear (84% Acetic Acid/64-19-7; 16% CL3A,CR 19.8130 Gins 0.0000 Gins 0.0000 Gins Water) [FP: >140oF) [HR: H3 F2] 226 2001-000-136 L 100 Gel Drying [25% Reagent Alcohol; 75% FL 1C, IR, OHH 39.6259 Gins 0.0000 Gins 0.0000 Gins Water] [FP: 88oF; BP: >100oF] [HR: H2 F3) 227 2001-000-144 L 100 IEF Anode Buffer [4% Water; 96% CR 15.8504 Gins 0.0000 Gins 0.0000 Gins PhosphoricAcid/7664-38-2) [pH: 1.1) (FP: None] [HR: H3 COR] 228 2001-000-146 L 100 IEF Cathode Buffer [93% Water; 1% IR,TX 9.9065 Gins 0.0000 Gins 0.0000 Gins Sodium Azlde/26628-22-8; 6% L-Lysine Monohydrate] [pH: 10.2) [FP: None] [L:C50-S: 2,000 mg/kg] [HR: H2] 229 2001-000-145 L 100 IEF Cathode Buffer [94% Water. 1% IR,TX 13.2086 · Gins 0.0000 Gins 0.0000 Gins Sodium Azide/26628-22-8; 3.4% L-Lysine Monohydrate; 3.4% L-Arginlne] [pH: 10.3) [FP: None) (L:C50-S: 2,000 mg/kg] (HR: H2) 230 2001-000-141 L 100 Native TrisGly Running Buffer [88% NH 79.2519 Gins 0.0000 Gins 0.0009 Gins Water; <3% Tris Base; >14% Glycine) [pH: 8.5) [FP: None) [HR: OJ 231 2001-000-147 L 100 NuPage Antioxidant [75% Water; 18% CR 13.6049 Gins 0.0000 Gins 0.0000 Gins -Sodium Bisulfate; 9% Dimethylformamlde; <1% ETDA] [pH: 2) [HR:H3Cor] 232 2001-000-151 L 100 t:JuPage LOS Sample Buffer [8% Water; NH 5.9439 Gins 0.0000 Gins 0.0000 Gins 40% Glycerol; 32% Tricine Gel Buffer; <2% EDTA, Lithium Oodecyl Suflate & Phenol Red] (pH: 7.2] (Flash Point: None) [HR:O] 233 2001-000-149 L 100 NuPage MES SOS Running Buffer [53% NH 158.5037 · Gins 0.0000 Gins 0.0000 Gins Water; 20% MES; 12% Tris Base; 15% SOS; <1% EOTA & NuPage Antioxidant) [pH: 5-6) [FP: None) (HR: OJ 234 2001-000-148 L 100 NuPage MOPS SOS Running Buffer NH 158.5037 Gins 0.0000 Gins 0.0000 Gins (53% Water; 20% MOPS; 12% Tris Base; 15% SOS; <1 % EDTA & NuPage Antioxidant) [pH: 5-6] [FP: None) [HR: OJ ,-··. "f ·--·-'- ~ .... CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing] CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing] CA3-125/Shipping & Receiving (New & Existing] CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing] CA3-125/Shipping & Receiving [New & Existing] CA3-125/Shipping & Receiving [New & Existing] LEV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount = Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 23 41111 4llilll Lillll \111111 ::.-~,. ?;·"'--"') -~---. ,, gr···1 :~,~·• n·,-· 1 --r1ra ~ ~----~--. ~ ~..,. (.----, .. lnvitrogen -1600 Faraday Avenue, Carlsbad CA -Building Inventory [Control Areas 1, 2, 3]: Hazardous Materials Inventory 235 2001-000-150 L 100 NuPage Transfer Buffer [83% Water, 8% NH 79.2519 Gins 0.0000 Gins 0.0000 Gins Bicine; 10% Bis Tris; <1% EDTA & I Chlorobutanol] [pH: 7.2] [FP: None] [HR: OJ 236 2001-000-152 L 100 Simply Blue Safe Slain [94.5% Water, CL3B,IR 105.6691 Gins 0.0000 Gins 0.0000 Gins 2% Citric Acid; 5% Ethanol/64-17-5) [pH: 2.1)[FP: >200oFJ[HR: F1 H2] 237 2001-000-138 L 100 Tricine SDS Running Buffer[>68% IR 79.2519 Gins 0.0000 Gins 0.0000 Gins Waler, 12% Tris Base, 18% Trk:!ne; >10% Sodium Dodecyl Sulfate] [FP: None] [pH: 8.25] [HR: H1] 238 2001-000-142 L 100 TrisGly SDS Running Buffer (>78% NH 158.5037 Gins 0.0000 Gins 0.0000 Gins Waler, 3% Tris Base; 14.5% Glycine; 10.3% Sodium Dodecyl Sulfate] [pH: 8.6] iFP: None] [HR: OJ 239 2001-000-143 L 100 TrisGly Transfer Buffer [85.3% Water, NH 79.2519 Gins 0.0900 Gins 0:0000 Gins 3.67% Tris ~ase; 18% Glycine] [pH: 8.6] [FP: None] [HR, OJ 240 2001-000-140 L 100 Zymogram Developing Buffer (84% NH 26.4173 Gins 0.0000 Gins 0.0000 Gins Water, <1% Calcium Chloride; 11.7% Sodium Chloride; 6% Tris Base; 7.3% 6N HCL; 0.1% Brij-35) [FP: None] [pH: 7.5) [HR: OJ 241 2001-000°139 L 100 Zymogram Renaturing Buffer [27% IR 26.4173 Gins 0.0000 Gins 0.0000 Gins Waler, 75% Triton X-100/9002-93-1] [FP: >200oF] [HR: H1] 242 1336-21-6 L >50 Ammonium Hydroxide [Aqua Ammonia] CR.TX 0.0000 Gins 0.5283 · Gins 0.0000 Gins [NH40H] [pH >13] [Base] [LD50-0ral: 350 mg/kg] [HR: HJ COR] 243 5949-29-1 s 100 Citric Acid Monohydrale [HR: H1] IR 3.3150 Lbs 0.0000 Lbs 0.0000 Lbs 244 67-68-5 L 100 Dimethyl Sulfoxide [DMSO] [Methyl CL3B, IR,SN 0.0240 Gins 0.0000 Gins 0.0000 Gins Sulfoxide) [RiboGreen-Component B [PicoGreen-Component A] [PicoGreen] [FP: 203oF; BP: 3720F] [LDS0-0: 14,500 mg/kg] [RTECS# PV6210000) [HR: H2 F1] n---··· ~ ..... ~ CA3-125/Shlpping & Receiving [New & Existing] ~,r· -, > :,. CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing] CA3-125/Shipping & Receiving [New & Existing) CA3-125/Shipping & Receiving [New & Existing) CA3- 137/Fermenlation [New] CAJ-138/Custom Services Production Lab[New] CA3-13B/Custom Services Production Lab[New] L_EV: Local or general/area exhaust ventilation required for Class I, II and Ill-A Liquids use•open conditions. CLY-Combustible Liquid Vapor.. FLY-Flammable Liquid Vapor. Storage Amount= Maximum amount In use and storage, unless otherwise noted. Not all m~terials are in use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system. 'HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 24 - ... ·---•.', ·-·. t', .... :~ ~ :_: ~ l·-··--~ r,,.-.... --;•·• fj'J 1··1rn .. , •..• .. C::. r.r; 'ffII :;-r·-,--, .. fffiiiiiliilll E(-.. lnvitrogen -1600 Faraday Avenue, Carlsbad CA-Building Inventory [Control Areas 1, 2, 3]: Hazardous Mat~rials Inventory 245 68-12-2 L 100 Dimethylformamide (N,N-) (DMF) [pH: 8) y (FP: 126oF; BP: 153oFJ (RTECS# LQ210000pJ (HR: H3 F2) 246 56-81-5 L 100 Glycerin [Glycerol] (1,2,3-Propanetriol] CL3B, IR, OHH 1.0567 Gins 0.0000 Gins 0.0000 Gins [Laemmuli Sample Buffer] (FP: 320oF; BP: 1820) (HR: H1 F1] 247 2650-17-1 s 100 Xylene Cyanole FF [Acid Blue) [Cl 42135) FS, IR 0.0332 Lbs 0:0000 Lbs 0.0000 Lbs [MP: 295oC) [HR: H2 F2] 248 75-05-8 L >f::50 Acetonilrile [Amidile Diluent] [FP: 42oF; FL1B,IR 39.0976 Gins 0.0000 Gins 0.0000 Gins y BP: 81oF) [LEL: 3; UEL: 16] [HR: H2 F3) 249 616-17-7 L 100 Cap B Solution [Cap B Solution Mix] [1-CR, FL1B 3.1701 Gins 0.0000 Gins 0.0000. Gins y Methylimidazole/616-47-7; Telrahydrofllran/109-99-9; Pyridine/110- 86-1] [FP: 1oF; BP: 133oF] [LEL: 2.6%; UEL: 12.8%] [HR: H3 F3 CORJ 250 2001-000-19 L 100 Deblock Solution [50% Methylene CA, CR, OHH, TX, 5.1250 Gins 0.0000 Gins 0.0000 Gins Chloride/75-09-2; 50% DichloroaceUc P65 Acid/79-43-6] [LC50: >5,000 ppm; LOSO- S: 1,111 mg/kg] [FP: None] [HR: H3 CORJ 251 75-09-2 L >/=70 Dichloromethane (Methylene Chloride) CA, CR, OHH, P65 3.1701 Gins 0.0000 Gins 0.0000 Gins [Methane Dichloride] [Freon 30] [BP: 104oF; FP: None) (HR: H3 CORI 252 2001-000-20 L 100 Oxidizer Solution [0.2M Iodine Solution in FL 1 B, IR 1.8228 Gins 0.0000 Gins 0.0000 Gins Tetrhydrofuran/109-99-9, Pyridine/110-86- 1) (HR: H2 F3] 253 2001-000-130 L 100 Solvent Mixture (AcelicAnhydride/108-24-CR, FL 1B, WR1 3.9890 Gins 0.0000 Gins 0.0000 Gins y 7; Pyridine/110-86-1; Tetrahydrofuran/109-99-9] [HR: H3 F3 R1 COR) -- 254 288-94-8* L 10 Telrazole (1-H-) (10% in Acetonilrile/75-FL1B,IR,UR2 3.0116 Gins 0.0000 Gins 0.0000 Gins y 05-8] [HR: H2 F2 R2] ;---.·1 CA3-138/Custom Seivices Production Lab(New) CA3-138/Custom Seivlces Production Lab[New] CA3-138/Custom Seivices Production Lab[New] FLV CA3-154/DNA Synthesis [Existing] FLV CA3-154/DNA Synthesis [Existing] CA3-154/DNA Synthesis [Existing) CA3-154/DNA Synthesis [Existing] FLV CA3-154/DNA Synthesis [Existing] FLV CA3-154/DNA Synthesis [Existing] FLV CA3-154/DNA Synthesis [Existing] LEV: Local or general/area exhaust ventilation required for Class 1,.11 and Ill-A Liqui~s use-open conditions. CLV-Combustible Liquid Vapor. FLV-Flammable Liquid Vapor. Storage Amount= Maximum amount in use and storage, unless otherwise noted. Not all materials are in use at the same time, with <10% in use at any time. Building is protected throughout by an automatic fire sprinkler system. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS· ERIKSEN-RATTAN ASSOCIATES INC. -04/23/2001 -PAGE 25 nrt I-! , \I l:J 11 11 11 I 1- 1 I I I I :I :, .... \ I I ~, _I- .I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 -April 2001 Prepared by Y Eriksen-Rattan Associates Inc. -4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or Ma_ryRattan@covad.net DEFINITIONS FOR ABBREVIATIONS HAZARDOUS MATERIALS INVENTORY ANALYSIS A: Aerosols • AL 1 -Aerosol Level 1 • AL2 -Aerosol Level 2 • AL3 -Aerosol Level 3 C: Cryogenics CA: Carcinogens CABS: Safety Cabinets • Approved/listed gas capinets • Approved/listed flammable liquids storage cabinets • Approved/listed hazardous materials storage cabinets CD: Combustible Dusts CF: Combustible Fibers CG: Compressed Gases CL: Combustible Liquids • CL2 -Combustible Liquids II • CL3A -Combustible Liquids Ill-A • CL38 -Combustible Liquids 111-8 CONC %: Concentration CP: Consumer Product -Not Regulated CR or COR: Corrosive CRY: Cryogenics • CRYF -Cryogenic Flammable • CRYO -Cryogenic Oxidizer EX: Explosive FG: Flammable Gas - Gaseous FGL: Flammable Gas - Liquefied FL: Flammable Liquid • FL 1A-Flammable Liquid 1-A • FL 1 B -Flammable Liquid 1-8 • FL 1 C -Flammable Liquid 1-C • Combination -IA + 1 8 + 1 C FS: Flammable Solid G: Gas Haz Class: Hazard Classification HR: Hazard Ranking • F -Flammability • H-Heafth • R -Reactivity HT: Highly Toxics IR: Irritants L: Liquid LG: Liquefied Gas LOC: Location/Control Area Name: • Chemical Name • Material Name • Product Name NFP: No Fire Point NH: Non-hazardous OHH: Other Health Hazards OP -Organic Peroxides • UD -Unclassified Detonable • OPJ -Organic Peroxide I • OP2 -Organic Peroxide If • OP3 -Organic Peroxide Ill • OP4 -Organic Peroxide IV • OPS -Organic Peroxid~ V OX: Oxidizer • OX -Oxidizer Gas • OX1 -Oxidizer 1 • OX2 -Oxidizer 2 • OX3 -Oxidizer 3 • OX4 -Oxidizer 4 PY: Pyrophoric RAD: Radioactive • RADA-Alpha • RADB-Beta • RADG -Gamma S: Solid SN: Sensitizers State: Material/Physical State TX: Toxic UC: Use-Closed System. UO: Use-Open System Units: • Cu-Curies • Cf -Cubic Feet- • Gins -·Gallons • Lbs -Pounds • MCc -Microcuries • MCi -Miflicuries UR: Unstable Reactive • UR1 -Unstable Reactive 1 • UR2 -Unstable Reactive 2 • UR3 -Unstable Reactive 3 • UR4 ,-Unstable Reactive 4 WR: Water Reactive • WR1 -Water Reactive 1 • WR2 -Water Reactive 2 • WR3 -Water Reactive 3 >15 psi: Pressure@>15 psig • CL Pressurized @ >15 psig • FG Pressurized @ >15 psig • FL pressurized @ >15 psig California & Federally Regulated Chemicals, - Materials & Substances: • P65: California Proposition 65 chemicals identified in California as Carcinogens or Reproductive/ Developmental Toxins [OHH] • PSM: OSHA Process Safety Management Acutely Hazardous Materials • RMP-T1: Federal Regulated Substances for Accidental Release Prevention • RMP-T2: Federal Regulated Flammable Substances for Accidental Release Prevention • RMP-T3: California Regulated Substances for Accidental Release Prevention NOTE: • Includes products/ mixtures/ materials containing regulated chemicals, materials & substances . • Includes materials, chemicals & substances identified through CAL- ARP in California. • Reporting/disclosure through CUPRA and/or Local/County/State Health or other agencies may be necessary -i.e.: Business Plan [BP], Risk Management Plan [RMP] or both. 'f'Eriksen-Rattan Associates Inc. 4719 Palm Avenue -La Mesa, California 91941 Telephone 619.466.6285 FAX 619.622.6233 EMAIL MaryRattan@thecoderes~urce.com or MaryRattan@covad.net 1/01 I Ir I I I I I I I I :I :I 'I I I I I INVITROGEN CORPORATION: 1600.Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 11 May 2001-[Rev.1] Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net This report is the property ·of Eriksen-Rattan Associates Inc. and was prepared exclusively for use by lnvitrogen Corporatiqn for the operations described in this report. Copies of this report retained by lnvitrogen Corporation shall be utilized only by them for occupancy classification and the Uniform/Califomia Code conditions addressed in this report. This report shall not be used for the purpose of construction for this project or any other project or for any other purpose. ll ll ll I II ll I I I I I I I I I I I I I INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by Y Eriksen-Rattan Associates Inc. 4719 Palm Avenue · La Mesa, California Telephone 619.466.6285 FAX 619.466.6233, EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net :I ... Uh, I I ' ;I., ... ,,,,, I STORAGE COMMODITY CLASSIFICATIONS UNIFORM/CALIFORNIA CODES ANALYSIS -UFC/CFC Article 81 1 2 3 Storage Commodities -Classification • Essentially noncombustible products on wooden or nonexpanded polyethylene solid deck pallets, in ordinary corrugated cartons with or without single-thickness dividers, or in ordinary paper wrappings with or without pallets. • Can contain a limited amount of Group A plastics [</=10% by weight or volume of . expanded or unexpanded plastic -includes packaging]. +Examples: • Appliances -noncombustible, electrical • Cement in bags • Ceramics • Dry insecticides • Glass • Glycol in metal cans • Gypsum board • Inert materials -bagged • Noncombustible liquids in plastic containers -</=5-gallon capacity • Noncombustible metal products + Class I products in slatted wooden crates, solid wooden boxes, multiple-thickness paperboard cartons or equivalent combustible packaging material with or without pallets. . + Can contain a limited amount of Group A plastics [</=10% by weight or volume of expanded or unexpanded plastic -includes packaging]. +Examples: • Incandescent or fluorescent light bulbs -cartooned • Thinly coated fine wire -reels or cartons + Wood, paper, natural fiber cloth -with or without pallets. + Group C plastics -with or without pallets. + Can contain limited amount of Group A or B plastics [</=10% by weight or volume of expanded or unexpanded plastic -includes packaging]. +Examples: • Aerosols -Level 1 • Combustible fiberboard • Fertilizers -bagged • Furniture -wood, natural fiber, upholstered, nonplastic, wood or metal with plastic- padded and covered arm rests • Glycol @ </=25% • Lubricating or hydraulic fluid in metal cans • Lumber • Noncombustible liquids in plastic containers ->5-gallon capacity • Paints -oil base in metal cans · • Paper -waste, baled • Paper -horizontal storage, or vertical storage that is banded or protected with . approved wrap • Paper in cardboard boxes • Plywood ' • Rags -baled • Wood -baled • Wood doors, frames, cabinets • Yarns-natural fiber & viscose T Eriksen-Rattan Associates Inc. -4719 Palm Avenue, La Mesa CA 91941 Telephone: 619.466.6285 FAX: 619.466.6233 EMAIL: MaryRattan@thecoderesource.com 1/01 -Page 1 of 4 !I :~ -~ I' . ·1 ·:,:··! I I STORAGE COMMODITY CLASSIFICATIONS UNIFORM/CALIFORNIA CODES ANALYSIS -UFC/CFC Article 81 Storage Commodities -Classification i~Nt~?::\,? ~: l§~i ~t:fu.fu.:~};1 !ri~1if.~f~l-~~}Tili~~?vrrtif:)i:Jt~As.ii::i:1'?:&t~-1}}~">k~1tf ., M~--~ 6t-j:;~tlF~~~~:·f.~~tliit':i .. lt~:t:4~l~J~1f :;~i:~~i 4 High-Hazard + Class I, If or Ill products containing Group A plastics in ordinary corrugated cartons - with or without pallets. + Class I, II & Ill products with Group A plastic packaging -with or without pallets. + Group B Plastics. + Free-flowing Group A plastics. + Limited amount of non-free flowing Group A plastics. +Examples: • Aerosols -Level 2 • Combustible metal products • Furniture -plastic upholstered • Furniture -wood or metal with plastic covering & padding • Glycol @ >25% & </=50% in combustible containers • Linoleum products • Paints -oil base in combustible containers • Shingles -asphalt • Thread or yam -synthetic or nonviscose + Products presenting special fire hazards beyond those of Class I-IV Commodities. +Class I, II, Ill or IV Commodities packaged in Group A Plastics where the weight or volume of Group A Plastics exceeds the following: • Unexpanded Plastic Packaging: >15% by weight. • Expanded Plastic Packaging: * >15% by weight; or * >25% by volume. +Examples: • Group A plastics not otherwise classified. • Aerosols -Level 3 • Flammable solids. • Glycol @ >/=50% in combustible containers. • Lacquers. • Lubricating or hydraulic fluids in plastic containers. • Idle combustible pallets & flats. • Paper-asphalt, rolled. • Paper-unbanded, vertical storage or unwrapped. • Pyroxylin • Rubber tires T Eriksen-Rattan Associates Inc. -4719 Palm Avenue, La Mesa CA 91941 Telephone: 619.466.6285 FAX: 619.466.6233 EMAIL: MaryRattan@thecoderesource.com 1/01 -Page 2 of 4 I I I I I I I 'I L,\ I I' I ' , ;:,\, I .,, \\,,,J 1· I ii }~·· ;I I .. :I I ,;,;·J I STORAGE COMMODITY CLASSIFICATIONS UNIFORM/CALIFORNIA CODES ANALYSIS -UFC/CFC Article 81 Storage Commodities -Classification- ~~~fkt~l1~irtt~:,I-~~~ ;_;,t~\{ti1~~f1t~i\f:~1:~rri1\~~~;\(~~yt~;rfl~1't:j~1R~~u~tl;1~~til~:l~~~~~:t~t?iti~~1~:ri~~ai~~~~-t~1t Group A Plastics + Plastic materials having a heat of combustion much higher than that of ordinary combustibles and a burning rate higher than that of Group B plastics. +Examples: • ABS [acrylonitrile-butadient-styrene copolymerj • Acetal [polyformaldehyde] • Acrylic [polymethyl methacrylate] •·Butyl Rubber • EPDM [ethylene-propylene rubber] • FRP [fiberglass-reinforced polyester] • Natural Rubber [expanded] • Nitrile Rubber [acrylonitrile-butadiene rubber] • PET or PETE [polyethylene terephthalateJ • Polybutadiene • Polycarbonate • Polyester Elastomer • Polyethylene • Polypropylene • -Polystyrene • Polyurethane • PVC [polyvinyl chloride >25% plasticized -i.e.: coated fabric unsupported film] • SAN [styrene acrylonitrileJ • SBR [styrene-butadiene rubber] Group B Plastics • Plastic materials having a heat of combustion-and a burning rate higher than ordinary combustibles, but as high as Group A Plastics. + Examples: , . • Cellulosics [cellulose acetate, cellulose acetate butyrate, ethyl cellulose] • Chloropre_ne Rubber • Fluorplastics [ECTFE, ethyelene-chlorotrifluoroethylene copolymer; ETFE, ethylene-tetrafluoroethylene copolymer; FEP, fluorinated ethylene-propylene copolymer] • Natural rubber [nonexpanded] • Nylon • PVC [polyvinyl chloride >5% & </=15% plasticized] • Silicone Rubber Group C Plastics + Plastic materials having a heat of combustion and burning rate similar to those of ordinary combustibles. +Examples: • Fluoroplastics [PCTFE, polychlorotrifluoroethylene; PTFE, polytetrafluoroethylene] • Melamine [melamine formaldehyde] • Phenol • PVC [polyvinyl chloride -rigid or plasticized <5% -i.e.: pipe, pipe fittings] • PVDC [polyvinylidene chloride]- • PVOF [polyvinylidene fluoride] • PVF [polyvinyl fluoride]. • Urea [urea formaldehyde] Encapsulated + Method of packaging consisting of a plastic sheet completely enclosing the sides and top of a pallet load. + Does not apply to banding with either metal or plastic straps, or individual plastic- enclosed items inside a nonplastic container. Nonencapsulated • Packaging that is not encapsul_ated as described above. + Includes a pallet load that is banded with metal or plastic straps, but that is not encapsulated as described above. TEriksen-Rattan Associates Inc. -4719 Palm Avenue, La Mesa CA 91941 Telephone: 619.466.6285 FAX: 619.4?6,6233 EMAIL: MaryRattan@thecoderesource.com 1/01 -Page 3 of 4 STORAGE. COMMODITY CLASSIFICATIONS UNIFORM/CALIFORNIA CODES ANALYSIS -UFC/CFC Article 81 Storage Commodities -Classification ::--J-,v.t,,>,~!t-~~""'::""'PJ)lJ11lff' ·ar,-f'A~~·rlf-::if~~ .re' ~4rr~~~v 'f;';;,.;_/'{,' y'A·~' '"'*' =--i ~~~o.av"")",'A"l-<"o/~~·~?-::' ,.,.~~,-~~rw·-q·1--i\,>,4~v"'.,..~1·~·"'A"""":~·'"""r-:~ ... '/-,A'd-lf..<.~'""""'?"'"~vv:.";.">---vw~M.~" A(-...' ~~'fi'~:tl,t:l~;¼ti ~.: ~ q ___ ~~~-~1:-·~~1: }l?);_;~t~~~lf~3t;:~;;1~:~'.f,~~¥ti;~1~~r'l½;~_ QB ~v t.19Jl~ti~~~!t~t~iffit~J~~::{t~~i·2t~Xl31~~ Binbox Storage Encapsulated High-Piled Combustible Storage Nonencapsulated Palletized Storage - Rack Storage Shelf Storage Shelving -Rack Storage +5-sided container with the open side facing an aisle. + Bin boxes are self-supporting or supported by a structure designed so that little or no horizontal or vertical space exists around the boxes. + Method of packaging consisting of a plastic sheet completely enclosing the sides and top of a pallet load. + Does not apply to banding with either metal or plastic straps, or individual plastic-enclosed items inside a nonplastic container. •Storage.of combustible materials in closely packed piles or combustible materials on pallets, in racks or on shelves where the top of storage exceeds the following conditions: • >/=12' above finished floor: Class I-IV Commodities. • >/=6' above finished floor: * Group A Plastics * High-Hazard Commodities * Flammable Liquids * Idle Combustible Pallets + Packaging that is not encapsulated as described above. + Includes a pallet load that is banded with metal or plastic straps, but that is not encapsulated as described above. +Storage on a material handling aid designed to support a unit load, with openings to provide access for material handling devices. · + Combination of vertical, horizontal and diagonal members that support stored materials. + Racks can be either fixed or portable. + Can including shelving, depending on automatic fire sprinkler system protection, commodities, and storage conditions. + Storage on shelves <30" deep, with the distance between shelves </=3' vertically. · + Storage height limited to </=12;. + Open Shelving: • Mesh, grated; slatted or similar shelves having uniform op~nings </=6" apart, comprising >/=50% of overall shelf area, with flue spaces at all 4 edges of the shelf. • Shelving having an area <32 sf, measured between flue spaces at all 4 edges of the shelf. • Solid Shelving: • Solid, slatted or other types of shelves located within racks that obstruct fire sprinkler water penetration through the racks. -• Shelving not meeting the definition of open shelving. _ T Eriksen-Rattan Associates Inc. -4719 Palm Avenue, La Mesa CA 91941 Telephone: 619.466.6285 FAX: 619.466.6233 EMAIL: MaryRattan@thecoderesource.com 1/01 -Page 4 of 4 11 -I II I I I I I I I I I 1· 1- 1 I I ·1 I. INVITROGEN CORPORA !ION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by T Eriksen-Rattan Asso~iates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net I I I I I I I 0 ·I : ' ' I I I' ' I I I I I ~;i,'.J •• I ·I .· ! DEFINITIONS FOR TERMS UNIFORM/CALIFORNIA CODES ~,'(){f.f-§MiL,<;Ji';«t~!0it!ii,:,.::.IQQ"'l>l!fQC~mJ'~i,ciln~~1~~(ijf~VJfr()'A'on1¢Q~ht:affi')r.iJl~.iie'il<ftf(iij~j?\i.:i\~~tl?{.%:~'1f,t;,j L}t-.~<:~-~'if~f~:,:u'l--t,ff::'i1~4.:":Z:~-·™ .. )!;.11~!'~, .. ,,,1~~ ... ,,,!.-#'Tl!S,.,., • .., ,,l'!r.--:-~~ff-..1..~. t..1;~1,,, f~-tk, . 1. .... ~J-i! ,, ::., ·-~ J>H~ , -~ , . ~ .... ~!-~~ ,, ,._, ,,,,~~-.u-h?~·t::n"'*:w$,:.£.it 0~:t:. Alternate Method of Compliance: · Conditions intended to provide materials or methods equivalent to the literal conditions set forth in the Code, as recognized through UBC/CBC 104.2.8 and/or UFC/CFC 103.1.2. Approved: Approval by/acceptable to the authority having jurisdiction [Fire Chief and/or Building Official, as applicable], as the result of review investigation or tests conducted by the authority having jurisdiction, or by reason of accepted _principles or tests by national authorities or technical or scientific organizations. Control Area: A building or portion of a building within which the exempt amounts of hazardous materials are allowed to be stored, dispensed, used or handled. A Control Area is generally addressed as a non-H Occupancy and classified as a 8, F or S Occupancy, depending on the operations/conditions involved. Each building is allowed to have up to.4 Control Areas. · Exempt Amounts per Control Area -Hazardous Materials: Types and amounts of materials allowed to be storea, dispensed, used or handled without application of H Occupancy or material hazard specific controls. Exempt Amounts are as identified in UBC/CBC Tables 3-D & 3-E_ and UFC/CFC Tables 7902.2-SA, 7903.2-8, 7903.3-A, 8001.15-A, 8001.15-B, 8001.15-C & 8001.15-0, with the amounts and conditions indicated allowed in each Control Area, with each building allowed to have 4 Control Areas. · Exit: The exit is that portion of the means of egress system between the exit access and the exit discharge or the public way. Some of the components that may be selectively included in the exit include exterior exit doors, exit enclosures, exit passageways and horizontal exits. . Exit Access: The exit access is that portion of a means of egress system between any occupied point in a building/structure arid adoor of the exit. Some of the components that may be selectively included in the exit access include aisles, hallways and corridors. Exit Discharge: The exit discharge is that portion of the means of egress system between the exit and the public way. Some of the components that may be selectively included in the exit discharge include exterior exit balconies, exterior exit stairways, exterior exit ramps, exit courts and yards. Exit,Discharge -Safe Dispersal Area: An area on the same property as the building being exited, with the proximity and size of the safe dispersal area based on factors such as the occupant load served, mobility of the oc_cupants, building construction type, building fire-protection features, building height and degree of hazard of the occupancy/use; with the safe dispersal area located >/=50' from the building served. Incompatible Materials: Materials which, when in contact with each other, have the potential to react in a manner that generates heat, fumes, gases or byproducts which are hazardous to life or property. Future: Conditions addressed in this report for work/operations that will be submitted separately for plan review/ permitting, with plans not included as part of the initial plan review/permit documents. Labeled: Equipment or material to which has been attached.a label, symbol or other identifying mark of a nationally recognized testing laboratory, inspection agency or other organization concerned with product evaluation that maintains periodic inspection of production of labeled equipment or Materials, and by whose labeling is indicated compliance with nationally recognized standards or tests to determine suit~ble usage in a specified manner. Listed: Equipment of Materials included on a list published by a nationally recognized testing laboratory, inspection agency or other organization concerned with product evaluation that maintains, periodic inspection of production or listed equipment or Materials, and whose listing states that equipment or Materials meet nationally recognized standards and have been tested and found suitable for use in a specified manner. , Means of Egress: An exit system that provides a continuous, unobstructed and undiminished path of exit travel from any occupied point in a building/structure to a public way. A means of egress system consists of 3 separate and distinct elements: ·exit Access, Exit, Exit Discharge Occupancy -B: Office, employee, administrative areas; labs; ancillary support operations. oc·cupancy-F1: Moderate hazard manufacturing/industrial operations for assembling, disassembling, fabricating, finishing, manufacturing, packaging, repair or processing operations that are not classified as H Occupancies. Occupancy -H2: Building or portion of a building where >Exempt Amounts of Flammable Gases, Organic Peroxides I, Oxidizers 3, Oxidizing Gases, Unstable Reactives 3-Nondetonable, Water Reactives 3 are used, stored or handled. Occupancy -H3: Building or portion of a building where >Exempt Amounts of Combustible Liquids II, Combustible Liquids Ill-A, Cryogens-Flammable or Oxidizing, Flammable Liquids I, Flammable Solids, Organic Peroxides II-IV, Oxidizers 1-2, Pyrophoric Liquids or Solids, Unstable Reactives 2, Water Reactives 2 are used, stored or handled. Occupancy -H7: Building or portion of a building where >Exempt Amounts of Corrosive, Highly Toxic or Toxic materials are used, stored or handled. Occupancy -S1: Moderate hazard storage operations that are not classified as Group H Occupancies. Owner: lnvitrogen Corporation. · · Storage: Product in closed vessels, with vessels not normally connected to piping for liquid transfer operations or not normally connected to systems or equipment involved in use operations. Use-Closed: Product in vessels or systems that are normally closed under conditions where product in the vessels or systems is not normally exposed to the atmosphere of the room or area in which the vessels/systems are located -[.e.: normally closed processes/vessels; liquid transfer into closed processes/vessels through a piping system . Use-Open: Product in processes/vessels where product is exposed to the atmosphere of the room or area where the product is located -i.e.: transfer/dispensing of liquids to/from vessels through other than a closed piping system; open process vessels/tanks. T Eriksen-Rattan Associates Inc. -4719 Palm Avenue, La Mesa CA 91941 Telephone: 619.466.6285 FAX: 619.466.6233 EMAIL: MaryRattan@thecoderesource.com 1/01 ll 11 I 11 ll I I I I I I I I ll I ,, I I .... , I, INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad.net . . . · .... : . I I I I I .I I. I I I I I I I I I. I I I INVITRO'GEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 11 May 2001 [Rev. 1) Prepared by Y Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource:com or MaryRattan@covad.net · -.._ :~_:--....i :--:...-'"'lTl ~illliililiilll ~-iiillia r1-iliiiiililii --,-,.r...._ ~lfililiiia nr-T :r····· ~,I-Tl ·''llliliiiiiilill ·---.. ---'"·"'··-·. ,,-·--:-·,. :_:_ L~~· ~~ ~ ~ ~-~I ~ ~· ~ ¼~ ~ : --~;--f~_ ~19111111j1 ~ ~~a ; :g-lnvitrogen -1600 Faraday Avenue, Carlsbad CA Nonflammable Vapor Exhaust Conditions -Class I Flammable Liquids Cubic Feet of Exhaust Material LFL 10% ofLFL Volumes of Air to Specific Vapor Ventilation Air Needed to Evaporation Time One Volume of Gravity Density Keep @10% LFL Per Gal of Assumed* Vapor Liquid Evaporated (Minutes) Control Area 1 -Room 128/Chemical Storage (Residual/Waste Materials) Acetonitrile (75-05-8) 3 0.30 332.333 0.786 1.42 19873.032 Ethanol [64-17-5) 3.3 0.33 302.030 0.800 1.59 16371.363 Methanol (67-56-1) 6 0.60 165.667 0.800 1.10 12651.830 Pyridine [ 110-86-1 ] 1.8 0.18 554.556 0.982 2.73 21790.504 Tetrahydrofuran [109-99-9) 1.8 0.18 554.556 0.888 2.50 21517.479 Control-Area 3 -Rooms 109, 118, 119, 121, 154 Room 109/T.C. Room (Existing Previously Approved/Permitted Operations] lsopropanol [67-63-0) 2 0.20 499.000 0.800 2.10. 20727.467 Room 118/Bulk Solution Ethanol [64-17-5) 3.3 0.33 302.030 0.800 1.59 16371.363 Gel Drying Solution 3.3 0.33 302.030 0.800 1.59 16371.363 Room 119/Clean Room Ethanol [64-17-5) 3.3 0.33 302,030 o.8po 1.59 16371.363 Gel Drying Solution 3.3 0.33 302.030 0.800 1.59 16371.363 Room 121/Manufacturing Acetonitrile [75-05-8) 3 0.30 332.333 0.786 1.42 19873.032 Butyl Alcohol [71-36-3) 1.4 0.14 713.286 0.800 2.60 24062.734 Ethanol [64-17-5) 3.3 0.33 302.030 0.800 1.59 16371.363 lsopropanol [67-63-0) 2 0.20 499.000 0.800 2.10 20727.467 Methanol [67-56-1) 6 0.60 165.667 0.800 1.fo 12651.830 Pyridine [110-86-1] 1.8 0.18 554.556 0.982 2.73 21790.504 ' Tetrahydrofuran [109-99-9) 1.8 0.18 554.556 0.888 2.50 21517.479 Room 154/DNA Synthesis [Existing Previously Approved/Permitted Operations) Acetonitrile [75-05-8) 3 0.30 332.333 0.786 1.42 19873.032 Ethanol [64-17-5) 3.3 0.33 302.030 0.800 1.59 16371.363 Methanol [67-56-1) 6 0.60 165.667 0.800 1.10 12651.830 Pyridine [110-86-1 J 1.8 0.18 554.556 · 0.982 2.73 21790.504 Tetrahydrofuran [109-99-9) 1.8 0.18 554.556 0.888 2.50 21517.479 "'Evaporation Time: Extremely conservative conditions assumed --complete evaporation: <1.06 gin = 1 o min; 1.06 gin = 20 min; 5.03 gin = 80 min 20 20 20 20 20· 10 20 80 20 20 20 10 20 10 20 10 10 10 10 10 10 10 Spill Scenario (Galloris) 1.06 1.06 1.06 1.06 1.06 0.25 1.06 5.03 1.06 1.06 0.40 0.11 1.06 0.40 1.06 0.40 0.40 0.40 0.40 0.40 0.40 0.40 CFM to Keep Evaporated Liquid at 10% LFL if All of the Liquid is Evaporated 1053 868 671 1155 1140 518 868 1029 868 868 397 265 868 829 671 872 861 795 655 506 872 861 5/11/01 Page 1 of 2 ;_JIii ~ c.. r···a· · q ~~,. ?I.' I . i f/7.-..iiill ~ slllllllial ;; --, ( ' r,_;.,__ ;,"-flilifiliili ~,q ~~ ---=-._-·-,, ... -·-·--·ur, ~ ~ ~ ~ ~ . . if.~ ~ :-...-.. -~ '°.... "lfll i'.'1::. .,._ lnvitr!)gen -1600 Faraday Avenue, Carlsbad CA Nonflammable Vapor Exhaust Conditions -Class I Flammable Liquids Definitions: Calculations: Worst Case Spill: CFM -Cubic Feet of Exhaust Ventilation Needed to Keep Vapors @ 10% LFL per Volume of Liquid Indicated LFL = Lower Flammable Limit Reference: NFPA Fire Protection Handbook [pp. 3-48] & NFPA 86 10% of LFL = 0.1xLFL Volume of Air to One Volume of Vapor= (100-10%LFL)/10%LFL Cubic Feet Exhaust Ventilatipn Needed to Keep@ 10%LFL Gallon of Liquid Evaporated= 10x[(8.382/0.075)]x[(specific gravity/vapor density)] x '[(100-10%LFL)/10%LFL] CFM = [Cubic Feet per Minute Exhaust Ventilation Needed to Keep @ 10% LFL Per Gallon of Liquid Evaporated] x [Gallons per Minute of Evaporated Liquid] Residual/Waste & New Liquids: </=4 liters [</=1.06 gallons]; .Bulk Solution/Room 118: </=20 liters [</=5.03+A12 gallons]. Materials @ <1.06 Gallons: Amount indicated is maximum amount indicated at any single location in the hazardous materials Inventory analysis [see Attachment 1]. . '- *Evaporation Time: Extremely conservative conditions assumed --complete evaporation: <1.06 gin= 10 min; 1.06 gin= 20 min; 5.03 gin= 80 min 5/11/01 Page 2 of2 I I I I I :I I ,1 I .. , I I I I I I I, .: .... I I I. INVITROGEN CORPORATION: 1600 Faraday Avenue, Carlsbad CA UNIFORM/CALIFORNIA CODES ANALYSIS 23 April 2001 Prepared by T Eriksen-Rattan Associates Inc. 4719 Palm Avenue La Mesa, California Telephone 619.466.6285 FAX 619.466.6233 EMAIL MaryRattan@thecoderesource.com or MaryRattan@covad:net This report is the property of Eriksen-Rattan Associates Inc. and was prepared exclusively for use by lnvitrogen Corporation for the operations described in this report. Copies of-this report retained by lnvitrogen Corporation shall be utilized only by them for occupancy classification and the Uniform/California Code conditions addressed in this report. This report shall not be used for the purpose of construction for this project or any other project or for any other purpose. • .. c:i 0 ...... '---' ' I\ . ' • -~ b ...- c:i 0 ' . I\ "h I-. ::c (.!) [jJ ::c _J LLJ :z ct. ~ . 21 '-8" [260] O.D. COOLER ©@@[b~rn3 II ' ,T"" 6' l J'-~' l s·-~· l 3'-4' l PLAN VIEW r!~ I "h IJ.O o.,1 ~ I "h • --I If 1 "h BACK ELEVATION SPECIFICATIONS CONSTRUCTION: 411 WOOD-FRAME WALLS POLYURETHANE FOAMED-IN-PLACE 5 1/211 WOOD-FRAME GEILIN6 POLYURETHANE FOAMED-IN-PLACE FINISH : SMOOTH WHITE INTERIOR SMOOTH WHITE EXTERIOR WALLS STUCCO &AL V. STEEL EXTERIOR GEILIN6 ACCESSORIES : I EA. -1211 X 8411 DOUBLE, LEAF COOLER DOOR I EA. -GANE BOLT AND DUTCH LATCH -SHIP LOOSE 2 EA. -1411 X 14" HEATED VIEW WINDOW I EA. -61 X 31 ANTHONY #ICf60 THREE (3) PANE HEATED VIEW WINDOW NOTE : LA& DOWN GEILIN6 EXTERIOR WALL PANEL KEY WAY----.. 1 / 4 • ANCHOR BOLTS OR HILTI Wl O ANCHORS @ 2J9 o.c. CONT. TOP GAP W,l#t, X 21 TEK t} SCREWS @23110.G. 2X4 HALL PANEL ' ~II X fl L.A6 BOLT AND WASHER @231 0.G. METAL 5~11 GEILIN6 PANEL CEILING TO WALL (WOOD-FRAME) INTERIOR 20 GA 7 ;a· X 7 ;a· CONT. #14 X 2 1/2• TEK SCREWS @ 2;t O.C. CAULKING EXTERIOR SILICONE INTERIOR WALL TO FLOOR (COOLER) WALL TO WALL (WOOD-FRAME) ~ 04/24/01 ADD: 5 1/211 HOOD-FRAME CEILING PETER REV, P.O.#P-282 COOLER CUSTOMER HAGGERTY REF. DATE BART DESCRIPTION BY NATIONAL COOLER MANUFACTURER OF WALK-IN COOLERS, FREEZERS, AND COLD STORAGE DOORS 420 E. ARROW HIGHWAY SAN DIMAS, CALIFORNIA 91773 TEL: (909) 592-8830 FAX: (909) 592-8890 DRAWN BY PETER CUSTOMERS t-------f---------.------1APPROVAL DWG. NO. DATE 04/11/01 t-------t----~---~MTE SCALE 1/4"=1 1-011 201-0498