HomeMy WebLinkAbout1600 FRAZIER AVE; ; CBR2020-1931; PermitBuilding Permit Finaled
Print Date: 10/14/2020
Job Address:
Permit Type:
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Project Title:
1600 FRAZIER AVE,
BLDG-Residential
1562125000
$2,761.92
Residential Permit
CARLSBAD, CA 92008-1102
Work Class:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check#:
Patio
Description: 224 SF ATTACHED PATIO COVER
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Property Owner:
NARAYANAN PADMAKUMAR AND USHASREE
1600 FRAZIER AVE
CARLSBAD, CA 92008
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $91.38 Total Payments To Date: $91.38
{city of
Carlsbad
Permit No: CBR2020-1931
Status:
Applied:
Issued:
Fina led Close Out:
Inspector:
Final Inspection:
Contractor:
CUSTOM BUILT INC
2521 ANTLERS WAY
Closed -Fina led
08/18/2020
09/15/2020
PBurn
10/14/2020
SAN MARCOS, CA 92078-2134
(760) 518-1623
Balance Due:
AMOUNT
$52.87
$37.01
$1.00
$0.50
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
{cicyof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Checkeffi20?0-l93il
Est. Value 2 , ,lJl 2 -
PC Deposit --------
Date Pr \'o-fD
Job Address I <coo Fo;,.,.~,:t'! ~ Ave . Suite: _-__ APN: _\_.,5:...,~:.,d-:;._..;I J.;...5-v ____ o_o __
CT/Project#:: ______________ :::;::-lot#:. __ _
Fire Sprinklers: YES G0 Air Conditioning: YES @ Electrical Panel Upgrade: YES ®
BRIEF DESCRIPTION OF WORK:
~ Addltlon/New: ____ LivingSF, ~4
Is this to create an Accessory Dwelling Unit? Y
Beck SF, Patio SF, ___ Garage SF
® New Fireplace? Y @it yes how many? __
O Remodel: ____ SF of affected area Is the area a conversion or change of use ? Y N
O Pool/Spa: ____ SF Additional Gas or Electrical Features? __________ _
QSolar: ___ KW, ___ Modules, Mounted: Roof Ground, Tilt: Y N, RMA: Y N,
Battery: Y N, Panel Upgrade: Y N
D Reroof: ____________________________ _
D Plumbing/Mechanical/Electrical Only: _____________________ _
D Other: _____________________________ _
DESIGN PROFESSIONAL CONTRACTOR BUSINESS;., , ! -,.
Name: NI,._ Name: C..us~ bu• I,: ANC.. •
Address: Address: @$:3,.\ At.,-\\~5 \JJ.,.._"f
City: ______ State:. ____ Zlp: ___ Oty: ~ MN:<,oS State:C..P,.. Zip: C{'a,o'::l-'Q
Phone: Phone: =1so<:? -$: I 8--I p e:-3
Email: Email:(c;:ti;AQ<M.~1 \t-,neorp@. ~~'· COM
Architect State License: State License: I 04qt;'-1'4 Bus. License: J3'fo~?f
(Sec. 7031,S Business and Profess tons Code: ArYf City or County which requires a permit to construd, alter, improve. demolish or repair any structure. prior to JU
Issuance, also requires the applicant for such permit to file a signed statement that he/she Is licensed pursuant to the provisJons of the Contractor's Uce:nse Law
{Chapter 9, commending with section 7000 of Division 3 Qf the Business and Professions COde} or that he/she Is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
PAnP.1 of? Rev. 03/20
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I heorby affirm under penalty of perjury Q!1§. of the fallowing dee/orations:
□ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
worl< Which this permit is issued.
l)G. have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for t.ti.e perform•~• of th~k for which this permit is issued.
My .. workers' C9tT'P..eryaV~-nJlffrance carri!( and policy number are: Insurance Compa_ny Name: ( ~ l JWtA .-SJ $.JfQ..O ( I
Policy No. L \J,...\t' L, \%l-,aa, Expiration Date: C¼:(ril ,' olcm,
□ Certificate of Exemption: I certify that In t rformance oft r ch this permit is issued, I shall not empJoy any person in any manner so as to be come
subject to the workers' compensation of ca · to re worbrs compensation mverap Is unlawful, and shaU subject an empto,fer to
criminal penalties and dvll ftnes up 100 compensation, damoges as provided for In Se<tfon 3706 of the Labor Code,
Interest and attorney's fees.
coNTRACTORSIGNATURE: ~=~'----\:::-:PJ-~'---..,._. _____ □AGENT DATE: B jloj J>oao
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License law far the /allowing reason:
□ I, as owner of the property or my employees with wases as their sole compensation, will do the work and the stnicture Is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who buHds or Improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement Is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale).
0 I, as owner of the property, am exclusively contractin, with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's Ucense Law).
□ I am exempt under Section _______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. YES NO
2. I (have/ have not) signed an application for a buildlns permit for the proposed work.
3. I have contracted with the follow ins person (firm) to provide the proposed constructlon (indude name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the followfnc person to coordinate, supervise and provide the major work (indude name/ address/ phone/
contractors' license number):
5. I will provide some of the work. but I have contracted (hired) the followlng persons to provide the work Indicated (include name/ address/ phone/ type of work):
OWNER SIGNATURE: □ AGENT DATE: _____ _ ----------------------
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction fending asencv for the performance of the work this permit Is Issued (Sec. 3097 (i) Civil Code).
Lendet'sName: ___________________ lender'sAddress: __________________ _
ONLY COMPLETE THE FOUOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future bulldln, occupant required to submit a business plan, acutely hazardous materials registration fonn or rJsk manaeement and prevention
program under Sections 25505, 25533 or 25S34 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes O No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE Of OCCUPANCY MAY NOT BE ISSUED' UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICf Of EMERGENCY SERVICES AND THE AIR POLUm0N CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information Is correct and that the Information on the plans is accurate. J agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE 0JY OF CARIS8AD AGAINST AU. UABIUTIES, JUDGMENTS, COSISAND EXl>ENSES WHICH MAY IN Am WAY ACCRUE AGAINSTSAID 01Y IN CONSEQUENCE OF
THE GRANTING OFTHIS PERMIT.OSHA: An OSHA permit Is required fore><aNal!ons over!lrf deep and demolition or coostruction of structures over 3 stories in height
EXPIRATION: Every permit Issued by
by such permit is not commenced
the work is CXllTVT1eind for a perlodbl11an,<,.,.
1635 Faraday Ave Carlsbad, CA 92008
B-1
shaR expire by limitation and become null and void ff the building or work authorized
buildirg or \NOl'k authorized by such permit Is suspended or abandoned at any time after
Ph: 760-602-2719 Fax: 760-602-8558
Page2of2
Email: Building@carlsbadca.gov
Rev. 03/20
Building Permit Inspection History Finaled
(City of
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2020-1931)
Permit Type: BLDG-Residential Application Date: 08/18/2020 Owner: COOWNER NARAYANAN
PADMAKUMAR AND USHASREE
Work Class: Patio Issue Date: 09/15/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 04/12/2021
IVR Number: 28091
Scheduled Actual Inspection Type Inspection No.
Date Start Date
10/14/2020 10/14/2020 BLDG-14 140777-2020
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item
BLDG-Building Deficiency
COMMENTS
BLDG-Final Inspection 140778-2020
Wednesday, October 14, 2020
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Inspection
Status
Passed
Passed
Address: 1600 FRAZIER AVE
CARLSBAD, CA 92008-1102
Primary Inspector Reinspection
Paul Burnette
Passed
Yes
Paul Burnette
Passed
Yes
No
No
Yes
No
Inspection
Complete
Complete
Page 1 of 1
L
j
(_ OV~J'o.~ o
?~i'~D\A
::. ;;l. 3 ~lo
~ ..
~'J,c../ 't> F-
/J~
f 4-~o UJ
-.... ---.
, I
J,....t') ~ :c -,1.f' ( .. ·CIP'4 ~+
City of Garlsbad
Building tDivision
J.+=====~· I m 0
I I~ C IC I I (t) 1 II'\ :) ;-====: 1 E,' ,It m ~
-+-----
T oeo3 "°'?"'i : •
Lc.1"'\~ ~f\.~~ 1-----
~{\~"':., o-.1-€..f i
~I'~ ~o~\, .t-=. --
l -
7
c.,~'i . ,\..~~
5~
C\4\!-(
fe,d2_L~t
~~,}f-'A~
\
.. --
: l
?t'O()?>-"e d ?e-1c;ol l)_ ~
:= lb' :><l~'; ~y~'
T'o o.!.. '?t"\~,.s\-= ;;) .. :!:> %
L
= l) ::, , N
(D O a,
(D •
I
L-----
~
4 :::.. \<ft=t-()
:: c)o,!}_0 ,~
City of Carlsbad
Building Division
SEP 1 5 2020
ISSUED BY: _.i__:J~...,,,::=....----
3\
fl
!
• #3 Lot coverage calc~lations: Lot size 9,806 sq feet
i
o House foo ri' t Ground Level 1,977 sq feet
o Footprint 20. %
i
o Proposed per~ola coverage 224 Sq Feet (14'X16')
o Footprint 2.3° o of property.
o Existin Per la covera e 256 Sq Feet (16'Xl6')
o Footprint 2.6° o of property.
• TOTAL ground lev 1 footprint= 25.1 %
!
• #4 Height: Pergola stucture will be approximately 96" height
o Flat/No Pitch rpen style lattice top.
• Distances from posts/to property lines:
o Approx. 24 ftt from Property line
• Indicate the dimensi~ns of the patio/pergola cover and the total
roofed area. . 1
o Proposed per ola coverage 224 Sq Feet (14'Xl6')
approx. 2.3% of property.
• Any easements on th property.
o City easemen located in the front yard of property.
o No impact wi proposed Pergola.
• Show slopes or topoJraphy of the lot:
o Land is grass-bver soil that is flat to lightly graded away from
house. I
!
Minimum Rafter Sizes
Rafter Rafter Spacina -Center to Center (in inches)
Span
6
7
8
9
1.0
11
b,~-./=7) 12
1.3
/y_~•· -)
\2.-a+iel' ~
/' 14)
·~
16
17
18
19
20
~ f 9 ',1 ~ ('I•
\...A ' 1'---y v • • N
12" (5/16" ply-
wood sheathing)
2x4
2x4
2x4
2x4
2x6
2x6
2x6
2x6
2x6
2x6
2x8
2x8
2x8
2x8
2x8
16" (1/2" ply-24" (1/2" ply-
wood sheathinal wood sheathina)
I 2x4 2x4 , 2x4 2x4
l 2x4 2x6
2x6 2x6
I 2x6 2x6
2x6 2x6
I 2x6 2x6
I 2x6 2x8
I 2x6 /" 2x8
I 2x8 -ZX8
I 2x8 2x8
I 2x8 2 X 10
I 2x8 2 X 10
2 X 10 2 X 10
I 2 X 10 2 X 10
Minimum Beam Sizes
Post Rafter Span (in feet)
Spaclni 4 6 8 10 12 14 16
4 4x4 4x4 4 xl4 4x4 4x4 4x4 4x4
8 4x4 4x4 4x4 4x4 4x4 4x4 4x4
8 4x4 4x4 4 x16 4x6 4X6 4x6 4x6
10 4x4 4x6 4x6 4x6 4x6 4x6 4x8
12 4x6 4x6 4xr 4x8 4x8 4x8 4x8
6x8 6x8
14 4x6 4x8 4X8 4x8 4x8 4 X 10 4 X 10
6x8 RV s:l 6 X 10
'3-,.\..'f ;;>. ., -'',do''
--. (la) 4x8 4x8 4x; 4 X 10 4 X 10 \ 4 X 1Q_.} 4 X 12
,/ 6x 6x8 6x8 6x 10 6 X 10
or, 7_0l"t"I ----4x8 4x8 4 X 10 4 X 10 4 X 10 4 X 12 4 X 12 18 6x8 6x8 6x8 6 X 10 6 X 10 6 X 10 .e. 1/>1)1' c.,.
20 4X8 4 X 10 4 X 10 4 X 12 4 X 12 4x 14 4 X 14
6x8 6x8 6 X 0 6 X 10 6 X 10 6 X 12 6 X 12
B-2 Page 3 of 8
32" (5/8" ply-
wood sheathinal
2x4
2x4
2x6
2x6
2x6
2x8
2x8
2x8 -
:l X 0 ?
2 X 10
2 X 10
2 X 10
2 X 10
2 X 12
2 X 12
18 20
4x4 4x4
4x4 4x6
4x6 4x6
4x8 4x8
4X8 4 X 10
6x8 6x8
4 X 10 4 X 10
6 X 10 6 X 10
4 X 12 4 X 14
6 X 10 6 X 10
4 X 14 4 X 14
6 X 12 6 X 12
6x 12 6x 14
Rev. 05/12
:>e.\-o~.
l--)·vet
TYPICAL R-1 PLOT PLAN
I
I I I I I LI-_-_____ .,..,--~
. .
---,-. f'·,.
' ..........,_ ·I
·--··--. ---,
(
10%
20%ofLOT
REAR YARD V't()TH TO A
MAX.~20'
PR0POSB)
AL'CX1IOH
EXISTfllORESllENCE
\
j LOT~TH IIEASURED 20'
FROM 2fJ BACK OF
FRONT PROPERTY LN:
------· I -~~':!.---..ti ..
I-
STREET
Setbacks shown are for R-1 parcels. Front Yard= 20' from the front property line. Interior side yard=
10% of lot width up to a maximum of 10'. (Min. 5'). Street side yard= 10'. Rear yard-20% of lot
width up to a maximum of 20' (Min. 10').
Maximum lot coverage= 40%. Include solid roof patios, attached or detached in the calculation.
Contact the Planning Division {760-602-4610) for information on corner lots, lots with unusual
configurations, lots within Planned Communities, accessory structures and building heights.
Solid Roof Patios -If roofing to be applied is TILE use the next, larger span/spacing on the following
tables.
Minimum Square Footing Sizes (inches)1·2
I
Post Rafter Span (in feet)
Spacing 6 8 1.0 12 1.4 1.8 1.8 20
4 12 12 12 12 12 12 12 12
6 12 12 12 12 12 12 12 14
8 12 12 12 12 12 14 14 14
10 12 12 12 14 14 14 16 16
1.2 12 12 14 14 16 16 18 18
1A 12 12 14 16 16 18 18 20
/ 16 J 12 14 14 16 18~ 18 20 20
-u 12 14 16 18 1\ 18 20 20 22
20 14 14 16 18 20 20 22 24
1. Assumes 1,000 psf soil bearing capacity <'., u-i'tl Ni~ E~c:.ea.cJ +SOL\?..~
2. The minimum depth for all footings Is 12 Inches Into natural grade Lo°'v c;
I V ~ ?,ar µo~" i ~ ::,.S ::> ~ ~n 51~
Page 2 of 8 -,s S...\ b s4 i +\J-kJ ror ~ I NJ ' B-2