HomeMy WebLinkAbout1603 FRAZIER AVE; ; CB150107; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
06-16-2015 Residential Permit Permit No: CB150107
Building Inspection Request Line (760) 602-2725
Job Address:1603 FRAZIER AV CBAD
Permit Type:RESDNTL Sub Type: SFD Status:ISSUED
Parcel No:1562124500 Lot #:13 Applied:12/20/2013
Valuation:$537,382.00 Constuction Type: 5B Entered By: RMA
Occupancy Group:Reference #: 0T120007 Plan Approved: 06/16/2015
# Dwelling Units:1 Structure Type: SFD Issued: 06/16/2015
Bedrooms:5 Bathrooms:4.5 Inspect Area:
Orig PC #: PC130070 Plan Check #:
Project Title:CARLSBAD 17-PLAN 3-PHASE 1
& BUILDOUT, 4356 SF, 652 SF GAR, 137 SF PORCH
Applicant:Owner:
CITY VENTURES
1900 QUAIL ST
NEWPORT BEACH CA 92660
858 248-7010
Building Permit $2,151.26 Meter Size FS3/4
Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00
Plan Check $1,505.88 Meter Fee $317.00
Add'I Plan Check Fee $0.00 SDCWA Fee $4,800.00
Plan Check Discount ($120.47)CFD Payoff Fee $0.00
Strong Motion Fee $69.86 PFF (3105540)$9,780.35
Park in Lieu Fee $0.00 PFF (4305540)$9,028.02
Park Fee $0.00 License Tax (3104193)$0.00
LFM Fee $0.00 License Tax (4304193)$0.00
Bridge Fee $0.00 Traffic Impact Fee (3105541)$3,100.00
Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00
BTD #2 Fee $0.00 Sidewalk Fee $0.00
BTD #3 Fee $0.00 PLUMBING TOTAL $0.00
Renewal Fee $0.00 ELECTRICAL TOTAL $0.00
Add'I Renewal Fee $0.00 MECHANICAL TOTAL $0.00
Other Building Fee $0.00 Housing Impact Fee $0.00
HMP Fee $0.00 Housing InLieu Fee $0.00
Pot. Water Con. Fee $5,604.00 Housing Credit Fee $0.00
Meter Size FS3/4 Master Drainage Fee $0.00
Add'I Pot. Water Con. Fee $0.00 Sewer Fee $842.00
Red. Water Con. Fee $0.00 Additional Fees $0.00
Green Bldg Stands (SB1473) Fee $22.00 Fire Sprinkler Fees $0.00
Green Bldg Stands Plan Chk Fee $0.00
TOTAL PERMIT FEES $37,099.90
Total Fees:$37,099.90 Total Payments to Date:$37,099.90 Balance Due:$0.00
FINAL APPROVAL
Inspector:1)'***/P Date:/21Z -/a Clearance:
NOTICE:Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions."You have 90 days from the date this permit was issued to protest imposition of these fees/exactions.If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030.Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project.NOR DOES IT APPLY to any
fees/exactions of which you have !Previously keen oiven a NOTICE similar to this. or as to which the statute of limitations has previously otherwise expired.
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Storm Water Pollution Prevention Plan (SWPPP) Permit
03-18-2015 Permit No:SW150036
Job Address:1603 FRAZIER AV CBAD
Permit Type:SWPPP Status:PENDING
Parcel No:1562124500 Lot #:13 Applied:12/20/2013
Reference #:CT120007 Entered By:RMA
CB#:Issued:
Inspect Area:
Project Title:CARLSBAD 17 -PHASE 1 & BUILD Tier:1
OUT Priority:M
Applicant:Owner:
CITY VENTURES
858 248-7010
Emergency Contact:
ANDY GERBER
858 248-7010
SWPPP Plan Check $0.00
SWPPP Inspections $224.00
Additional Fees $0.00
TOTAL PERMIT FEES $224.00
Total Fees:$224.00 Total Payments To Date:$0.00 Balance Due:$224.00
FINAL APPROVAL
DATEIzie:RANCE
SIGNATAE_
PERMIT INSPECTION HISTORY REPORT (CB150107)
BLDG-Residential 12/20/2013Application Date:Permit Type:Owner:
Subdivision:Single Family Detached 06/16/2015Work Class:Issue Date:
1603 Frazier Av
Carlsbad, CA
Address:06/19/2017Expiration Date:Status:
IVR Number: 704480
Closed - Finaled
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection CompleteActual
Start Date
12/07/2016 12/07/2016 BLDG-Final
Inspection
004493-2016 Failed Paul Burnette Reinspection Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
12/12/2016 12/12/2016 BLDG-Final
Inspection
005069-2016 Passed Paul Burnette Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
December 12, 2016 Page 1 of 1
Inspection List
Permit#:C8150107 Type:RESDNTL SFD CARLSBAD 17-PLAN 3-PHASE 1
& BUILDOUT, 4356 SF, 652 SF GAR, 137 S
Date Inspection Item Inspector Act Comments
06/20/2016 17 Interior Lath/Drywall PD AP
06/20/2016 23 Gas/Test/Repairs PD AP
06/14/2016 16 Insulation PD AP
06/14/2016 16 Insulation PD AP
06/09/2016 84 Rough Combo PD AP
05/25/2016 13 Shear Panels/HD's PD AP
05/16/2016 13 Shear Panels/HD's PD NR
05/16/2016 13 Shear Panels/HD's PD NR
05/11/2016 15 Roof/Reroof PD AP
05/10/2016 15 Roof/Reroof PD NR
03/28/2016 11 Ftg/Foundation/Piers PD AP
03/14/2016 21 Underground/Under Floor PD AP
03/14/2016 22 Sewer/Water Service PD AP
Friday, January 06, 2017 Page 1 of 1
CB150107 1603 FRAZIER AV
\,../CITY OF
CARLSBAD INSPECTION RECORDBuildingAC RLSBAD 17 -PLAN 3-PHASE 1
&Filill DOUT, 4356 SF, 652 SF GAR, 137 SF PORCH
Division RESDNTL SFD
1/4'•SPECTION RECORD CARD WITH APPROVED Lot#:13 CITY VENTURES
S MUST BE KEPT ON THE JOB
WI RECALL BEFORE liskpm FOR NEXT WORK DAY INSPECTION ORD COPYEtFOR BUILDING INSPECTION CALL:7604024725 C
OR GO TO: www.Carisbadca.gov/Build[pg AND CLICK ON"Request ns •-tion"
DATE:0 e
IF "YES"IS CHECKED BELOW THAT DIVISION'S APPROVAL IS REQUIRED PRIOR TO REQUESTING A FINAL BUILDING INSPECTION
-
IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW.AFTER
ALL REQUIRED APPROVALS ARE SIGNED OFF—FAX TO 760 602 8560 EMAIL TO BLDGINSPECTIONS_I OR
BRING IN A Copy OF THIS CARD TO:1635 FARADAY AVE.. cARLsBAD CA 92008.BUILDING INSPECTORS CAN BE REACHED
AT 760-602-2700 BETWEEN 7:30 AM —8:00 AM THE DAY OF YOUR INSPECTION.
•
NO Required Prior to Requesting Building Final If Checked YES
CM&I (Engineering Inspections)760 38-3891 Call before 2 pm
(760-944-8463 Allow 48 hours
Date inspector
...-
Notes
Planning/Landscape
...../(it
Fire Prevention
-4
760-602-4660 Allow 48 hours
iZ-6*ZCAt
\1 9114 CA.
A
Type of Inspection Type of Inspection
CODE S BUILDING Date Inspector cooE #ELECTRICAL Date Ap4-pector
ff#11 FOUNDATION /_#31 0 ELECTRIC UNDERGROUND C]-LIFER Uffll -Inlirlr -
#12 REINFORCED STEEL
•#34 ROUGH ELECTRIC
MASONRY PRE GROUT
-,..10 TILT PANELS#
#33 0 ELECTRIC SERVICE 0 TEMPORARY
0 GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC
#39 FINAL
#11 POUR STRIPS co.#MECHANICAL
#11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS &PIPING
#14 SUBFRAME 0 FLOOR 0 CEILING /#44 0 DUCT &PLENUM 0 REF. PIPING
#15 ROOF SHEATHING .3---
•/. /-i #43 HEAT-AIR COND. SYSTEMS
#13 EAT. SHEAR PANELS 71 -
_115.101111:1 %
#16 INSULATION .4-G gra =CODE it COMBO INSPECTION
#18 EXTERIOR LATH /#81 UNDERGROUND (11,12,21,31)
f
#17 .,INTERIOR LATH &DRYWALL (./•O.el #82 DRYWALL,IEXT LATH, GAS TES (17,18,23)
#51 POOL EXCA/STEEL/BOND/FENCE
#83 ROOF SHEATING, EXT SHEAR (13,15)i
#55 PREPIASTER/ FINAL
#84 FRAME ROUGH COMBO (14,24,34,44)=war 4..di
#19 FINAL
#85 T-Bar (14,24,34,44)
cops #PLUMBING Date Inspector #89 FINAL OCCUPANCY (19,29,39,49)
#22 13 SEWER & BL/CO CI PL/CO I .FIRE Date Ins •ector
#21 UNDERGROUND OWASTE (3 WTR
•"Alaid1111.11111111111.111111111111111.111111
#24 TOP OUT 0 WASTE 0 WIR ,
A/S UNDERGROUND VISUAL
#27 TUB &SHOWER PAN /'A/S UNDERGROUND HYDRO
,#23 0 GAS TEST 0 GAS PIPING A/S UNDERGROUND FLUSH
#25 WATER HEATER A/S OVERHEAD VISUAL MT=.•.
-.l'"---
#28 SOLAR WATER A/S OVERHEAD HYDROSTATIC WARM ..-----.---e
#29 FINAL A/S FINAL
'IIIIVIIIIII 0 .
CODE #STORM WATER F/A ROUGH-IN Illalli 4
AI PRE-CONSTRUCTION MEETING F/A FINAL
FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN
17)0145 NOTICE TO CLEAN FIXED MING SYSTEM HYDROSTATIC TEST
#607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL
#609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST MEM
#610 VERBAL WARNING MEDICAL GAS FINAL
OPV 1/1...(11 2 CPC OM'V cno eocemAt utn.rrek