Loading...
HomeMy WebLinkAbout1607 NEW CREST CT; ; CB152810; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 09-09-2015 Pool Permit Permit No: CB 152810 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC #: Project Title: 1607 NEW CREST CTCBAD POOL 2159505300 Lot #: 0 $34,952.00 Construction Type: NEW DERTSAKIAN RES- 656 SF POOL 256 SF PATIO COVER, GAS TO BBQ & FIRE PIT, ELECT Status: ISSUED Applied: 08/28/2015 Entered By: RMA Plan Approved: 09/09/2015 Issued: 09/09/2015 Inspect Area: Applicant: Owner: BACKYARD VACATIONS 206 CALGARY CT - VISTA CA 92083 619-921-1412 Building Permit . $310.09 Addi Building Permit Fee . $0.00 Plan Check $217.06 Add'l Plan Check Fee . $0.00 ElectricalFee $33.00 Plumbing Fee . $33.00 Strong Motion Fee . $4.54 Green Bldg'Standards (5B1473) Fee $2.00 Renewal Fee . $0.00 -' Add'l Renewal Fee • $0.00 Other Building Fee . $0.00 Additional Fees $0.00 TOTAL PERMIT FEES . $599.69 Total Fees: $599.69 Total Payments To Date: . $599.69 Balance Due: $0.00 FINAL Inspector: k' . Date:/2P/ 7A5/ Clearance. NOTICE: Please take NOTICE th/approval of your project includes the Irrlpositior/' f fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." Yoti have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a), and file the pretest and any other required information with the City Manager for processing in accordance with Carlsbad Murridpal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capadty changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this pred. NOR DOES IT APPLY to any fees/exactions of which you have oreviousiy been civen a NOTICE similar to this, or as to which the statute of limitations has rxeviouslv otherwise exared. City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit 09-092015 Permit No:SW150336 Job Address: 1607 NEW CREST CT CBAD Permit Type: SWPPP Status: ISSUED Parcel No: 2159505300 Lot #: 0 Applied: 08/28/2015 Reference #: Entered By: RMA CB#: CB152810 Issued: 09/09/2015 Inspect Area: Project Title: DERTSAKIAN POOL Tier: 1 Priority: L Applicant: Owner: BACKYARD VACATIONS N P Y.UCAIPA ACQUISITION L P 1067 YONGE ST 206 CALGARY CT TORONTO ONTARIO VISTA CA 92083 CANADA M4W 21-2 00000 619-921-1412 Emergency Contact: JUSTIN CUMMINGS [WI'45W SWPPP Plan Check $48.00 SWPPP Inspections $58.00 Additional Fees $0.00 TOTAL PERMIT FEES $106.00 Total Fees: $106.00 Total Payments To Date: $106.00 Balance Due: $0.00 FINAL APP DATE12&EARA SIGNATUREfkj I THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPLANNING'-, 0 ENGINEERING 0 BUILDING 0 FIRE 0 HEALTH DHAzMATIAPcD I ' Building Permit. Application RIO City' of 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558j email: buiIdingcarlsbadcagov p , CC rl S b a d www.carlsbadca.gov J V' Plan Check 'Nor /5 6010 Est. Value 7L/ ' Plan Ck.ePo I, Date F' clswppp I JOB ADDRESS tj2 ol (!;;I- SUrrE#/SPACE#/UNITe c 4cL 53 OJ' CT/PROJECT #. •, , - LOT ' PHASE #. TFUNITS #BEDROOMS' A BATHROOMS TENANT BUSINESS NAME ' " CONSTR. TYPE 0CC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area Ds Ck1 SIC) 40 L 'C, : 'Do\' EXISTI G1JI ' PROPOSED USE , ]GARAGE (SF). PATIOS (SF) DECKS (SF) FIREPLACE YESA. NOJ AIR CONDITIONING ' YES I:INo , FIRE SPRINKLERS YES NoII APPLICANT NAME ' PROPERTY OWNER NA Prtnaryeo at ADDRESS • . ' ' ADDRESS (.fl \- CITY ' , STATE ZIP CITY TA' C ZIP PHO4 ç 3ç4 FAX PHONE FAX EMAIL ' EMAIL '- DESIGN PROFESSIONAL I ' ' , ' ' ' - . ' CONTRACTOR BUS. t11k .izO ADDRESS ADD (') CITY . STATE ZIP CITY TE . PHONE ' FAX c~k L4(FI EMAIL ' ' - . - E A , ISTATE LIC # ' . Idi,c permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the the provisions of the Contractor's License Law jChapter 9, commending with Section 7000 of Division 3 of the the alleged exemption. Any violation of Section 7031.5 by any applicant for apermit subjects the applicant to a oiø Workers' Compensation Declaration: hereby affinn under penalty of pe4uiy one of the following declarations: I havà and will maIntaIn a certificate of consent to self.lnsure for workers' compensation as provided by Section 3700 of the Labor Code, for the perfonnance of the work for which this permit is issued. I have and will maintain workers' compensation, as quired by Section 3700 of the Labor Co e, for the performance the wo for which this rmitls issued. My rkers' compensation! surance4rrte d policy number are: Insurance Co. w'UA.& (3\JJ.fj)LA.. () 1GNS'V ' C) ' "piraion Date _ This section need not be completed if the permit is for one hundred doIIar$100) or Ie [] Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner seas to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secu.F.-Ilvirs, compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, da ~elsprovidedforl~le~nll,of the Labor code, Interest and attorney's fees AT CONTRACTOR SIGNATURE .S'.Q_.') - ENT • DATE •, DOOGD (?O®1) I hereby affirm that lam exempt from Contractor's License LaW for the following reason: ' ' '- [] I, as owner of the property or my employees with wages as their sole compensation, will dojp.wor1rSliS1Fe structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereonjnd'ffifio does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of comonthe owner-builder will have the burden of proving that he did not build or improve'for the purpose of sale). [J I, as owner of the property, am exclusively contracting with licensed coj(fadt'rs to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply loan owner of property who builds or improves thereon, and contracts for sucl , jects with contractor(s) licensed pursuant to the Contractor's License Law). - [] I am exempt under Secti1.on - Business and P,Iessions Code for this reason:1 11 - - - 7 ' 1. I personally plan to provide the major labor- and materials for construction of the proposed property improvement. Dyes I]No ' • - 2.1 (have! have not) signed an application fofrbling permit for the proposed work. • . ' - I have contracted with the following pepn (firm) to provide the proposed construction (include name address phone lcontractors' license number): ' I plan to provide portions ó the wo ut I have hired the following person to coordinate, supervise and provide the major work (include name! address! phone !contractors' license number): 5.! will provide some of the work, Ihave contracted (hired) the following persons to provide the work indicated (include name! address! phone !type of work): 'PROPERTY OWNER SIGN LiRE • (tk'\.k .__,1)ç'" •' ' [:]AGENT DATE • - - - (Sec. 7031.5 Business and Professions Code: Any City or County which requires a applicant for such permit to file a signed statement that he is licensed pursuant ti Business and Professions Code) or that he is exempt therefrom, and the basis for civil penalty of not more than five hundred dollars ($500)).' Is the applicant or future building occupant tequired to submit a business plan, acutely hazardous materials registration fonn'or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? CI Yes CI No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTiFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY-SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. . wow hereby affirm that there is a construction.Iendirig agency for the performance f thework this permit is issued (Sec. 3097 (I) Civil Code). Lender's Name Lender's Address oc IceilIfythatI have read the application and statethattheabove Information Is coffectandth the Information on the plans Isaccurate. I agreeto complywith all City ordinances and Slate lanvis relatingtobuiIdlngconsbvctlon. I hreby authorize representativie of theCityof Caitthad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THECFTY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMrr: OSHA An OSHA permit isrequired for excavations over 50' deep and demolition or construction of structures over 3stories in height. EXPIRATION: Everypermit issued by the Building OffidaIuer the provisions of this Code shall expire by limitation and become null and void it the building or work authorized by such permit is not commenced within 180daYshom thedaeofsthPenmtorffthebu9frauthorizedbYsuohrm" su dedorabandoned at any time after the woikismmenosd for apedodof 180 days (Sedion 106.4.4 Uniform Building Code). LAPPLICANT'S SIGNATURE --- ( Inspection List Permit#: CB152810 Type: POOL DERTSAKIAN RES- 656 SF POOL 256 SF PATIO COVER, GAS TO BBQ & Fl Date Inspection Item Inspector. Act Comments 03/18/2016 59 Final Pool - RI 03/17/2016 59 Final Pool - RI 03/17/2016 59 Final Pool PY AP 03/11/2016 19 Final Structural - RI PATIO COVER 03/11/2016 59 Final Pool - RI POOL 03/10/2016 19 Final Structural PY CO 02/04/2016 55 Fence/Pre-Plaster PB AP 02/04/2016 59 Final Pool PB NR 02/03/2016 55 Fence/Pre-Plaster PB NR 09/21/2015 21 Underground/Under Floor PB AP 09/21/2015 31 Underground/Conduit-Wirin PB AP 09/21/2015 51 Excav/Steel/Bonding/Fence PB AP . 09/16/2015 51 Excav/Steel/Bonding/Fence PB NR Tuesday, March 22, 2016 Page 1 of 1 4.1 caty of Carlsbad PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 09/08/2015 PROJECT NAME: DERKSAKIAN POOL AND SPA PROJECT ID: CB152810 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 1607 NEW CREST CT APN: 2159505300 VALUATION: $34,952 SCOPE OF WORK: POOL AND SPA, GAS BBQ AND FIREPIT This plan check review is complete and has been APPROVED by: LAND DEVELOPMENT ENGINEERING DIVISION r IT Final Inspection by Construction Management & Inspection Division is required: Yes L:l No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: CARIEJONES@HOTMAIL.COM To determine status by one of the divisions listed below, please contact 760-602-2719. LAND DEVELOPMENT1 760-602-2750 j BOW fl Chris Sexton Chris Glàssen 71 Greg Ryan L .1 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christopher.Glassen@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov ri 7] VaiRay Nelson [ Dominic Fieri VN 760-602-2741 L_J 760-602-4664 ValRay.Marshall@carlsbadca.gov Dominic.Fjeri@carlsbadca.gov Remarks: AJQid3 LO DERKSAKIAN POOL AND SPA PLAN CHECK NO# 1 Outstanding issues are marked with VN . Items that conform to permit nnIrrsrusii. requirements are marked with L?.J or have intentionally been left blank. 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: EJ F,71 North arrow j IJ Driveway widths L:J . i:z:i Existing & proposed structures EJ Existing or proposed sewer lateral Existing street improvements LJ EJ Existing or proposed water service EJ LJ Property lines (show all dimensions) EJ Submit on signed approved plans: ci Easements DWG No. LJ I LZJ Right-of-way width & adjacent. streets Show on site plan: EJ [73 Drainage patterns and proposed site elevations. Show all high points. E3 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". 13 Existing & proposed slopes and topography• =Size, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. Lj EJ Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: F-71 Site address [73 Assessor's parcel number 123 Legal description/lot number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show all existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No. LOT 15 MAP 15521 Subdivision/Tract: Cr 0306 Reference No(s): E-36 Page 2 of 6 REV 6/01/12 DERKSAKIAN POOL AND SPA PLAN CHECK NO# 1 DISCRETIONARY APPROVAL COMPLIANCE • N/A I I Project does not comply with the following engineering conditions of approval for project no.: DEDICATION REQUIREMENTS N/A Dedication for all street rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all flew buildings and for remodels with a value at or exceeding I24.000.O0 , pursuant to Carlsbad Municipal Code Section 18.40.030: i::i Dedication required as follows: IMPROVEMENT REQUIREMENTS N/A =,=All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $120,000.00, pursuant to Carlsbad Municipal Code Section 18.40.040. I = Public improvements required as follows: Construction of the public improvements must be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee, so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the city prior to issuance of a building permit. = Future public improvements required as follows: E-36 Pae 3 of 6 REV 6101112 DERKSAKIAN POOL AND SPA PLAN CHECK NO# 1 GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. I- Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING' Grading Permit required. NOTE: The grading permit must be issued and rough grading approval obtained prior to issuance of a building permit. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector The inspector will then provide the engineering counter with a release for the building permit. No grading permit required. =1= Minor Grading Permit required. See additional comments for project- speciflc requirements. 6. MISCELLANEOUS PERMITS J RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work ALL WORK adjacent to the public right-of-way. Types of work include, but are nOt limited to: street WILL REMAIN improvements, tree trimming, driveway construction, tying into public storm drain, sewer and OUT OF PUBLIC water utilities. RIGHT OF WAY AS PER PLAN IEI Right-of-way permit required for: E-36 Page 4of6 REV 6/01/12 DERKSAKIAN POOL AND SPA PLAN CHECK NO # 1 7. STORM WATER Construction Compliance i::i LZJ Project Threat Assessment Form complete. E:J LJ Enclosed Project Threat Assessment Form incomplete. LZJ Requires Tier 1 Storm Water Pollution Prevention Plan (E-29). Please complete attached form and return (SW15-336 EJ Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSMP) Compliance EJ Storm Water Standards Questionnaire. Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. EJ Indicate areas of impervious surfaces (patios,walkway, etc. ) and pervious areas (landscaping). EJ Project needs to incorporate low impact development strategies throughout in one or more of the following ways: EJ Rainwater harvesting (rain barrels or cistern) J Vegetated Roof EJ Bio-retentions cell/rain garden EJ Pervious pavement/pavers EJ Flow-through planter/vegetated or rock drip line J Vegetated swales or rock infiltration swales EJ Downspouts disconnect and discharge over landscape J Other: E-36 Page 5of6 REV 6/01/12 DERKSAKIAN POOL AND SPA PLAN CHECK NO # 1 WATER METER REVIEW Domestic (potable) Use N/A EJ =What size meter is reqtiired? EJ i1 Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the. meter necessary to meet the water use requirements. ffl For residential units the minimum size meter '.shal! be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger, than one quarter (1/4) acre where the meter size shall be 3h". FEES i EJ Required fees have been entered in building permit. LJ L:J Drainage fee applicable Added square feet Added square footage in last two years? U yes LI no Permit No. Permit No. Project built after 1980 yes Eno Impervious surface> 50% ayes E:1 no Impact unconstructed facility ayes Elno EJ Fire sprinklers required Jyes Uno (is addition Upgrade El yes UJno over 150' from centerline) No fees required , ADDITIONAL COMMENTS Attachments U Engineering Application L Storm Water Form Li Right-of-Way Application/ Into. Cl Reference Documents E-36 Page 6of6 ' REV 6/01/12 4 IN> CITY OF CAR LSBAD STORM WATER COMPLIANCE ASSESSMENT B-24 Develonment Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov I am applying to the City of Carlsbad for the following type(s) of construction permit: Building Permit U Right-of-Way Permit U My project is categorically EXEMPT from Electrical Patio/Deck the requirement to prepare a storm water Fire Additional Photo Voltaic pollution prevention plan (SWPPP) because it issuance the only requires of one or more of Fire Alarm Fixed Systems Re-Roofing Sign Mechanical Spa-Factory following permit types: Mobile Home Sprinkler Plumbing Water Discharge Project Storm Water Threat Assessment Criteria* No Threat Assessment Criteria O My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the no threat' assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level. My project does not meet any of the High, Moderate or Low Threat criteria described below. Tie M4.Low Threat Assessment Criteria project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more-of the following criteria: Results in some soil disturbance; and/or I Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). Tier 2 - Moderate Threat Assessment Criteria 0 My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or, Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). Tier 3 - Significant Threat Assessment Criteria 0 My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or O My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or. O My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). ciS -°c3-00 Project Address: Assessor Parcel No. tL2o Authorized Agent Name: Title: M Owner/Owner's Authorized Agent Signature: —z,Th Date: City Concurrence: YESDNO By: J Date: () P777RO I certify to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards. 'The City Engineer may authorize minor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher Construction SWPPP Tier Level is warranted. B-24 Page 1 of 1 Rev.03/09 STORM WATER POLLUTION PREVENTION NOTES ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPS WHEN RAIN IS EMINENT. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. SPECIAL NOTES PROJECT INFORMATION Site Address: 1 1O(fl 4Qii tf C Assessor's Parcel Numb N ICI 'r: Project ID: 5)/5OJ3 Construction Permit No.: Estimated Construction Start Date 1 \S \6 Project Duration Months Emergency Contact: Name: Lk5-M. cLUTN_LLA 24 hour Phone: Gtt4 \(4 Perceived Threat to Storm Water Quality o Medium w If medium box is checked, must attach a site plan sheet showing proposed work area and location of proposed structural BMPs For City Use Only CITY OF CARLSBAD STANDARD TIER 1 SWPPP Approved By: Date: - Z ^,A, tl~llk CITY OF STORM WATER COMPLIANCE FORM TIER I CONSTRUCTION SWPPP E-29 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov STORM WATER COMPLIANCE CERTIFICATE I My project is not in a category of permit types exempt from the Construction SWPPP requirements I My project is not located inside or within 200 feet of an environmentally sensitive area with a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). I My project does not require a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code) I My project will not result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets one or more of the additional following criteria: located within 200 feet of an environmentally sensitive area or the Pacific Ocean: and/or, disturbed area is located on a slope with a grade at or exceeding 5 horizontal to I vertical; and/or disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS. I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS: AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER I CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSB D.\ iDL OWNER(S)/OWNER'S AGENT NAME (PRINT) OWNER(S)/OWNER'S AGENT NAME (SIGNATURE) DA E E-29 Page 1 of 3 REV 4/30/10 CD -3 0CDCOCDC) 3 E MQ 3aO CD U'13 0)CD 10 03 0(0 51 o. CD )CW -a . x9O Q) :3. 256RnRe 2 - _ 2 a CDCD&°a 0)0)co ce D. ! g. x. --to C, 0 CD ..w 2.1go o >0 R. CDDCDCD .(D o oCD CD 0)03 U ncn CD •oo—.•=_• O cncCD0 a CD- 00 Ow (D°Co'' CL .CD — =CflCD0. X(0CDC CD • . -.= U o 0. Cn 107 in ' 0a I CA 0 003 D . 0CD(I)°° 0) — 3CD g' !. Cn CD _2 Or >o =r., c cD2.F8 CD U) 0 An 0 C) — -u 3 a 5. " 0 CD 0 M CO 0) CO CD 0 -'I C) C, — (n 0 ,5. , (00 CO O(D . )C° >Cr 0 . - g' og: Drn CD Cal EC-7 Geotextiles & Mats - EC -8 Wood Mulching EC Earth Dikes and - Drainage Swales CD - - - - - - - - - - - - - EC-1 I Slope Drains SE-1 Silt Fence --- SE-3 Sediment Trap SE-4 Check Dam CA a ---------------- 3 I ) SE-5 Fiber Rolls Gravel Bag Berm --- - - - - - - - - - - - - - - SE -7 Street Sweeping and Vacuuming WE SE-8 Sandbag Barrier -u SE-la Storm Drain Inlet Protection TR-1 Stabilized Construction Ingress/Egress C) - - - - - - - - - - - - - TR-2 Stabilized Construction Roadway " 2. NS-1 Water Conservation Practices NS-3 Paving and Grinding w e 02 Ooerations 02 NS-7 Potable Water/Irrigation Oz t4A SE-6 NS-8 Vehicle and Equipment Cleaning U) ---------- WM-1 Material Delivery and tnrirze WM-2 Material Use o WM-3 Stockpile Management WM-4 Spill Prevention and 03 Control - WM-5 Solid Waste — Mnriement w CL ME WM-6 Hazardous Waste Mnnpment 4I L4 -Ml WM-8 Concrete Waste Mnanement CD 11111 1 CITY OF CAR LSBAD PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division APPROVAL 1635 Faraday Avenue (760) 602-4610 P29 www.carIsbadca.ov DATE: 2-28-15 PROJECT NAME: PROJECT ID: PLAN CHECK NO: CB 15-2810 SET#: I ADDRESS: 1607 New Crest Ct APN: Z This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required Yes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: For questions or clarifications on the attached checklist please contact the following reviewer as marked: , PLANNING ENGINEERING FIRE PREVENTION .... 760 602-4610 760-602-2750, 760-602- 4665 Chris Sexton Chris Glassen Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christopher.GIassen@carIsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz VaiRay Marshall Cindy Wong 760-602-4675 760-602-2741 760-602-4662 Gina.Ruiz@carIsbadca.gov VaIRay.MarshaII@carlsbadca.gov Cynthip.WonE@carlsbadca.gov Linda Ontiveros Dominic Fieri 760-602-2773 760-602-4664 Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: NPDES INSPECTION REPORT Building Division Pursuant to CMC 15.12. 100 I Date I //.-/J'-/.STProject# I Inspector 79 ;/(;.. Time 300 Ptf I CBPermit# 152.7/0 Inspection Type $Cohipliance 0 Follow Up Weather I o Heavy Rain 0 Light Rain Xsunny 0 Cloudy I 0 Partly Cloudy 0 Rain Expected at _% chance BMP IMPLEMENTATION AND COMPLIANCE BMP and Compliance ° CORRECTIVE ACTION REQUIRED Activity > Are all inactive slopes properly stabilized? 0 Provide additional erosion control. 0 Repair/replace erosion control BMPs. 0 Replace brokón rock/sand bags. Are areas flatter than 3:1 covered or protected? - X Are gravel bags, waddles, silt fences, and other erosion control BMPs in place and functioning properly? - 0 Desiltation/retention basin(s) requires maintenance. 0 Provide additional perimeter controls. Repair/replace perimeter controls. 0 Impervious surfaces need to be swept. 0 Prevent sediment tracking on to street. 0 Clean in and around storm drains. Do basins appear to be maintained as required? - ) Are perimeter control BMPs maintained? - Is the entrance stabilized to prevent tracking? - - 1S Are storm drain inlets protected and BMPs maintained? - . Are all material and equipment handling, storage and repair areas clean and maintained? 0 Provide additional protection at storm drain inlets. 0 Discard unusable equipment and materials. Remove trash and debris from project site. 0 Properly store hazardous materials. - Immediately clean up spills and leaks. Are dumpsters and trash receptacles covered? - Has trash and debris accumulated throughout the site? - - - Are stockpiles and spoils protected from runoff? Are landscaped areas protected from erosion? - - - Are natural areas and open spaces protected? - - 0 Maintenance required for washout areas. Protect/Cover materials stored outdoors. 0 Provide spill kit(s) in equipment storage areas. Are washout areas maintained and protected? - Were there any discharges observed - during the inspection? 0 Provide cover for dumpster and trash receptacles. 0 Immediately discontinue washing or hosing. 0 Relocate portable restrooms away from storm drains and/or to level areas. Is the SWPPP wall map up to date and accurate? - - Was the SWPPP reviewed during this inspection? - - - Are portable restrooms located away from the storm drain and on level ground? Provide secondary containment for portable restrooms. - Do portable restrooms have secondary containment? - Z.0 Provide additional emergency BMPs. Are BMPs stockpiled for emergency deployment? - - - 0 Train staff on pollution prevention. Other: - 0 Other:_______________________________________ THIS SERVES AS A WARNING NOTICE. Implement corrective actions by /1- Z-0-15 . A City Inspector will return on or after the correction date to verify that corrective actions were completed and/or BMPs implemented as required. If you have - - - any questions or comments, please contact your inspector. Comments: 0 NO VIOLATIONS OBSERVED DURING THE INSPECTION. 0 VIOLATIONS WERE NOTED DURING THE INSPECTION. O 15.12.050 Prohibited Discharge 0 15.16.170 Unlawful Acts O 15.12.080(E) Reduction of Pollutants 0 6.08.030 Receptacles Generally - $ 15.12.090 Storm Water Conveyance System Protection 0 6.08.040 Cleanliness of Solid Waste Receptacles O 15.12.110 Failure to Implement Corrective Actions $. 6.08.050 Solid Waste Receptacles to be Kept Covered O 1512.120 Containment, cleanup, and notification of spills PL 6.08.090 Unlawful Placement of Solid Waste O Other_________________ I Received By - Please Print I Received 0 Mailed I Date Ins nturej W-S*~nat - --- The Notice Serves As: I 0 Verbal Warning 19, Written Warning 'J Field Memo 0 Referred for Action BMP Assessment 5 4 3 2 1 I Knowledge Assessment 4 3 2 1 0 Contact not available (circle one) circle one) ( White: BLDG Yellow: Job Site