Loading...
HomeMy WebLinkAbout1608 MARITIME DR; ; CB162962; Permit10-20-2016 Job Address: Permit Type: Parcel No: Reference #: PC#: Project Title: Applicant: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plumbing/Mechanical/Electrical (PME) Permit Permit No: CB162962 Building Inspection Request Line (760) 602-2725 1608 MARITIME DR CBAD PME 2150821900 KLENNER: REPLACE FURNACE I ADDNC Lot#: 0 Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 08/02/2016 JMA 08/02/2016 08/02/2016 MAUZY HEATING & AIR KLENNER Plumbing Fees Electrical Fees Mechanical Fees Other PME Fees TOTAL PERMIT FEES 1608 MARITIME DR CARLSBAD CA 92011 $0.00 $0.00 $163.00 $0.00 $163.00 Total Fees: $163.00 Total Payments To Date: $163.00 Balance Due: Inspector: Clearance: $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. THE FOLLOWING A'PPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0ENGINEERING 0BUILDING OFIRE OHEALTH OHAZMAT/APCD I (City of Carlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov Plan Check No. (6/ b. ZP( (pl.--- Est. Value Plan Ck. Dep9sit Date g / -z.--/ lb lsWPPP SUITE#/SPACE#/UNIT# I APN CT/PROJECT # I LOT# I PHASE# I# OF UNITS I# BEDROOMS #BATHROOMS I TENANT BUSINESS NAME I CONSTR. TYPE I occ. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) ~ kv ~C 6"'-cb{~ ~ -to<' C.lo u EXISTING USE PROPOSED USE I GARAGE (SF) PATIOS (SF) !DECKS (SF) FIREPIJ\CE lAIR CONDITIONING ' I FIRE SPRINKLERS YEsQt_ NoD YES DNa D 1 YESO NoD APPLICANT NAME , " , L , a , Primary Contact t' \. ]...,.-(_\---.. U \ IA.-rl\(),y-, CITY , \ _ L. v -.lr J. 0 STATE ZIP? I We~ -c. ~'~~~e. CJ>. ~I .)fb L EMAIL EMAIL DESIGN PROFESSIONAL ADDRESS CITY ZIP ZIP t:\20 'l l STATE cn~J c~or-STATE cl\ PHONE EMAIL EMAIL I STATE LIC. # ' CLASS ,, I CITY BUS. LIC.# Clo/C1.ol fJ , 1. 3! 'S lO (Sec. 7031.5 Bus1ness and Professions Code: Any C1ty or County wh1ch requires a perm1t to construct, alter, 1mprove, demoliSh or repair any structure, pnor to 1ts 1ssuance, also requires the applicant for such permit to file a sig;ned statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0.J.have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ~I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work or whici)Jhis p rmit is issued. My workers' compensaliiJn · suran carrier and policy number are: Insurance Co. ~ ~ Policy No. M tJv L 2-'\\. ~ Expiration Dale r cH This section need not be completed i e permit is for one hundred dollars ($1 00) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subjec1 to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000}, in addition to the cost of compensation, damages as 3706 of the Labor code, interest and attorney's fees. Ji5 CONTRACTOR SIGNATURE 12(AGENT I hereby affinn that I am exempt from Contractor's Ucense Law for the following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale}. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's LicE,nse Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law}. I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes 0No 2. I (have I have not} signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number}: 5. I will provide some of the work, but I have contracted (hired} the following persons to provide the work indicated (include name I address I phone I type of work}: Ji5 PROPERTY OWNER SIGNATURE DATE I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all CH;y ordinances and State lav.s relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentklned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEf' HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA perm~ is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and vokl if the buik:ling or v.ork authorized by such permit is not commenced within 180 days from the date of such permit or if the building orv.ork authorized by such permit is suspended or abandoned at any time after the v.ork is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). ~APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. (Office Use Only) STATE ZIP ZIP CA PHONE FAX DELIVERY OPTIONS PICK UP: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) o ASSOCIATED CB#---------·---MAIL TO: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) o NO CHANGE IN USE/ NO CONSTRUCTION MAIL/ FAX TO OTHER:-----------------o CHANGE OF USE/ NO CONSTRUCTION ~APPLICANT'S SIGNATURE DATE PERMIT INSPECTION HISTORY REPORT (CB162962) BLDG-Residential 08/02/2016Application Date:Permit Type:Owner: Subdivision:P/M/E 08/02/2016Work Class:Issue Date: 1608 Maritime Dr Carlsbad, CA Address:Issued - Active 01/30/2017Expiration Date:Status: IVR Number: 716154 Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection CompleteActual Start Date 12/06/2016 12/06/2016 BLDG-43 Air Cond./Furnace Set 004281-2016 Passed Andy Krogh Complete BLDG-Final Inspection 004280-2016 Passed Andy Krogh Complete COMMENTS PassedChecklist Item BLDG-Mechanical Final Yes BLDG-Electrical Final Yes December 15, 2016 Page 1 of 1 CERTIFICATE OF COMPLIANCE CFlR-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) (Page 1 of3) Project Name: _ JEFF KLENNER I Date Prepared: 2016-07-26 A. General Information CFlR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CFlR-ALT-02 document for each dwelling unit. 01 Project Name JEFF KLENNER 02 Date Prepared 2016-07-26 03 Project Location 1608 MARITIME DRIVE 04 Building Type Single family OS CACity Carlsbad 06 Dwelling Unit Name JEFF KLENNER 07 Zip Code 92011 08 Dwelling Unit Conditioned 2691 Floor Area (ft2) Number of space conditioning 09 Climate Zone 7 10 (SC) systems in this dwelling 1 unit. ---------- B. Space Conditioning (SC) System Information 01 02 03 04 OS 06 07 08 09 10 Is the SC Installing a SCSystem SCSystem CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SCsystem? Alteration Type System 1 Location 1 2691 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib) This section does not apply to this project. Registration Number: 216-A0279591A-OOOOOOOOO-OOOO Registration Date/Time: 2016-07-26 22:23:59 HERS Provider: CaiCERTS CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version: 2013 Rev 1.007 Schema Version: O.SSSSDD Report Generated: 2016-07-26 22:23:44 CERTIFICATE OF COMPLIANCE CFlR-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) 01 02 03 04 OS 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R-Value Central gas All new Central split All new This field or This field or System 1 heating AFUE 80 cooling SEER 25 Setback section is not section is not furnace components AC components applicable applicable B!lguired Dgcumentation: CF2R-MCH-Ol-E-Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF3R-MCH-20-H-Duct Leakage testing required when heating or cooling components are installed inducted systems, or when more than 40ft of duct length is replaced. -Leakage rate compliance: S 15%, or s 10% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow~ 300 CFM/ton required when MCH-25 is required. Exce(!tiQn~: -Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements. -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2{b)1Diia and 150.2{b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) Registration Number: 216-A0279591A-OOOOOOOOO-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance This section does not apply to this project. Registration Date/Time: 2016-07-26 22:23:59 Report Version: 2013 Rev 1.007 Schema Version: 0.55SSDD HERS Provider: CaiCERTS Report Generated: 2016-07-26 22:23:44 CERTIFICATE OF COMPLIANCE CFlR-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-lR-ALT-HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: c..A1atthew L/11auz3 Mauzy, Matthew Company: Signature Date: M N MAUZY MECHANICAL INC 2016-07-26 22:23:59 Address: CEA/ HERS Certification Identification (if applicable): 1551 N CUYAMACA STREET City/State/Zip: Phone: EL CAJON CA 92020 619-583-9545 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: c..A1atthew L/11auz3 Mauzy, Matthew Company: Date Signed: M N MAUZY MECHANICAL INC 2016-07-26 22:23:59 Address: License: 1551 N CUYAMACA STREET 759171 City/State/Zip: Phone: EL CAJON CA 92020 619-583-9545 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0279591A-OOOOOOOOO-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance Registration Date/Time: 2016-07-26 22:23:59 Report Version: 2013 Rev 1.007 Schema Version: O.SSSSDD HERS Provider: CaiCERTS Report Generated: 2016-07-26 22:23:44 . CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Jeff Klenner Enforcement Agency: City of Permit Number: CB162962 Carlsbad Dwelling Address: 1608 Maritime Drive City: Carlsbad Zip Code: 92011 [HOUSE] A. System Information 01 Space Conditioning System Identification or Name SYSTEM 1 02 Space Conditioning System Location or Area Served WHOLE HOUSE 03 Building Type from CF-1R Single family 04 Verified Low Leakage Ducts in Conditioned Space No, credit is not taken (VLLDCS) Credit from CF1R? OS Verified Low Leakage Air Handling Unit Credit from No, credit is not taken CF1R? 06 Duct System Compliance Category Alteration MCH-20d -Complete Replacement or Altered Duct System B. Duct Leakage Diagnostic Test 01 Condenser Nominal Cooling Capacity (ton) s.o 02 Heating Capacity (kBtu/h) 110 03 Conditioned Floor Area served by this HVAC system (ft2) 2691 04 Duct Leakage Test Condition Test final OS Duct Leakage Test Method Total leakage 06 Leakage Factor 0.1S 07 Air Handling Unit Airflow (AHUAirflow) Determination Cooling system method Method 08 Measured AHUAirflow 0.0 09 Calculated Target Allowable Duct Leakage Rate (cfm) 300.00 10 Actual duct leakage rate from leakage test measurement 190.0 (cfm) 11 Compliance Statement: System passes leakage test Registration Number: 416-A0003702A-M2000002A-M20A Registration Date/Time: 2016-08-29 14:17:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 Report Generated: 2016-08-29 14:17:16 . CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) B. Duct Leakage Diagnostic Test 12 I Notes: C. Additional Requirements for Compliance 01 System was tested in its normal operation condition. No temporary taping allowed. Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage 02 testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 03 If a complete replacement, all supply and return register boots were sealed to the drywall. 04 Building cavities were not used as plenums or platform returns in lieu of ducts. OS If cloth backed tape was used it was covered with Mastic and draw bands. 06 All connection points between the air handler and the supply and return plenums are completely sealed. If the system complies using the Smoke Test method, the smoke test was conducted in accordance with the requirements 07 of Reference Residential Appendix RA3.1.4.3.6. Systems that comply using smoke test shall not be included in sample groups for HERS verification compliance. 08 Verification Status Pass-all applicable requirements are met 09 Correction Notes for this table The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 I Complies: All specified verification protocol requirements on this document are met. Registration Number: 416-A0003702A-M2000002A-M20A CA Building Energy Efficiency Standards Registration Date/Time: 2016-08-29 14:17:09 HERS Provider: CHEERS 2013 Residential Compliance Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 Report Generated: 2016-08-29 14:17:16 CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Timothy Ceausu Tlnnothyc~ Company: Date Signed: I Permit E Raters 2016-08-29 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive City/State/Zip: Phone: Westlake Village CA 93291 818-735-7886 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Mauzy Heating, Air & Solar Responsible Builder or Installer Name: Matt Mauzy HERS Provider Data Registry Information Sample Group Number (if applicable): HERS Rater Information HERS Rater Company Name: I Permit E Raters Responsible Rater Name: Timothy Ceausu Responsible Rater Certification Number w/ this HERS Provider: RCN13063 Registration Number: 416-A0003702A-M2000002A-M20A CA Building Energy Efficiency Standards 2013 Residential Compliance CSLB License: 759171 Dwelling Test Status in Sample Group (if applicable) N/A Responsible Rater Signature: Tlnnothyc~ Date Signed: 2016-08-29 Digitally signed by CHEERSrr". This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Date/Time: 2016-08-29 14:17:09 HERS Provider: CHEERS Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 Report Generated: 2016-08-29 14:17:16 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of 7) Project Name: Jeff Klenner Enforcement Agency: City of Carlsbad Permit Number: CB162962 Dwelling Address: 1608 Maritime Drive [HOUSE] City: Carlsbad Zip Code: A. General Information 01 Dwelling Unit Name HOUSE 02 Climate Zone 03 Dwelling Unit Total Conditioned Floor 2691 04 Number of Space Conditioning Area (ft2) Systems in this Dwelling Unit. OS Certificate of Compliance Type Prescriptive alterations (CF1R-ALT) 06 Method used to Calculate HVAC Loads 07 Calculated Dwelling Unit Sensible This field or section is not applicable 08 Calculated Dwelling Unit Heating Load Cooling Load (Btuh) (Btuh) 09 Dwelling Unit Number of Bedrooms 3 MCH-Olb Prescriptive Alterations -Space Conditioning Systems Ducts and Fans B. Space Conditioning (SC) System Information 01 02 03 04 SC System SC System CFA served Is the SC Identification or Location or Area by this SC system a Name Served System (ft2) ducted system? SYSTEM 1 WHOLE HOUSE 2691 Yes Registration Number: 416-A0003702A-M0100001A-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance OS 06 07 Installing a Installing new SC Installing more refrigerant system than 40 feet of containing components? ducts? component? Yes Yes No Registration Date/Time: 2016-08-29 02:10:36 Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 08 Installing entirely new duct system? No 92011 7 1 NotApplicableEquipmentChangeout This field or section is not applicable 09 10 Installing entirely new SC Alteration Type system? Altered space No conditioning system HERS Provider: CHEERS Report Generated: 2016-08-29 14:10:40 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans C. Space Conditioning (SC) System Alterations Compliance Information 01 02 03 04 OS 06 07 08 09 Heating Cooling System Altered Heating Minimum Altered Cooling Minimum Identification Heating Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency or Name System Type Component Type Value System Type Components Type Value All new All new SYSTEM 1 Central gas heating AFUE 0.80 Central cooling SEER 25 furnace componen split AC ts components D. Installed Heating Equipment Information 01 02 03 04 OS System Identification or Heating Efficiency Heating Unit Heating Unit Name Heating Efficiency Type Value Manufacturer Model Number SYSTEM 1 AFUE 80.0 LENNOX SL280UH110V60C -04 Notes: ----------- Registration Number: 416-A0003702A-M0100001A-OOOO Registration Date/Time: 2016-08-29 02:10:36 CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 CF2R-MCH-01-E (Page 2 of 7) 10 11 12 13 Central Fan Integrated New or (CFI) Required Replaced New Ventilation Thermostat Duct Duct System Type Length R-Value Status This field N/A-no or Setback ducts sectio Not a CFI n is system replaced not applic able 06 07 Heating Unit serial Rated Heating Capacity, number Output (BTUH) 5916G01533 110000 HERS Provider: CHEERS Report Generated: 2016-08-29 14:10:40 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans E. Installed Cooling Equipment information 01 02 03 04 OS 06 Condenser or Package Unit Condenser or Condenser or Condenser or System Identification Cooling Efficiency Cooling Efficiency Package Unit Package Unit Package Unit or Name Type Value SYSTEM 1 SEER 25.0 Notes: F. Extension of Existing Duct System, Greater Than 40 Feet G. Installed Duct System information H. Installed Air Filter Device Information I. Air Filter Device Requirements Registration Number: 416-A0003702A-M0100001A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance Manufacturer Model Number Serial Number LENNOX XC25-060-230-5816018596 02 This section does not apply to this project. This section does not apply to this project. This section does not apply to this project. This section does not apply to this project. Registration Date/Time: 2016-08-29 02:10:36 Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 CF2R-MCH-01-E (Page 3 of 7) 07 08 System Rated Cooling Condenser Rated Capacity at Design Nominal Capacity Conditions (BTUH) (ton) I 60000 5.0 HERS Provider: CHEERS Report Generated: 2016-08-29 14:10:40 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans J. HERS Verification Requirements 01 02 03 04 MCH20 Exemption System SC System From Duct Duct Identification or Location or Area Leakage Leakage Name Served Requirements Test SYSTEM 1 WHOLE HOUSE No Yes exemptions Notes: Registration Number: 416-A0003702A-M0100001A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance OS 06 07 MCH21 MCH22 Exemption from Minimum R-Value for Ducts In Ducts Located AHU Fan Conditioned In Cond Space Efficacy Space Verification (W/cfm) This field or section is No No not applicable ------- Registration Date/Time: 2016-08-29 02:10:36 Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 CF2R-MCH-01-E (Page 4 of 7) 08 09 10 MCH23 MCH25 MCH28 AHU Airflow Rate Refrigerant Return Duct Design (cfm/ton) Charge Table 150.0-C or D No No No ----- HERS Provider: CHEERS Report Generated: 2016-08-29 14:10:40 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of 7) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment 01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b). 03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 150.0(h)l and 2). 04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet-to-outlet temperature rise specification. See Section 150.0(h)4. OS Standby Losses and Pilot Lights: Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d). Cooling Equipment 06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3, and Section 150.0(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A. 09 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 150.0(h)l and 2. Air Distribution System Ducts, Plenums and Fans 10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section 150.0(m)l. Registration Number: 416-A0003702A-M0100001A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance Registration Date/Time: 2016-08-29 02:10:36 Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 HERS Provider: CHEERS Report Generated: 2016-08-29 14:10:40 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 6 of 7) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 11 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 12 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 13 The thermostat shall be installed in accordance with the manufacturers published installation specifications 14 First stage of heating shall be assigned to heat pump heating. 15 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met. The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 416-A0003702A-M0100001A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance Registration Date/Time: 2016-08-29 02:10:36 Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 HERS Provider: CHEERS Report Generated: 2016-08-29 14:10:40 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of 7) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Matt Mauzy ~ cU:t ~ CI.-U%.Y Company: Signature Date: Mauzy Heating, Air & Solar 2016-08-29 Address: CEA/ HERS Certification Identification (if applicable): 9411 Bond Avenue City/State/Zip: Phone: El Cajon CA 92021 619-448-9545 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Matt Mauzy Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Mauzy Heating, Air & Solar Address: 9411 Bond Avenue City/State/Zip: El Cajon CA 92021 Registration Number: 416-A0003702A-M0100001A-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance Responsible Builder/Installer Signature: ~cd:t~CI.-U%.Y Position With Company (Title): Contractor/Installer CSLB License: 759171 Phone: I Date Signed: 619-448-9545 2016-08-29 Digitally signed by CHEERS'M. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Date/Time: 2016-08-29 02:10:36 Report Version: 2013 Rev 1.007 Schema Version: 2013.1.007 HERS Provider: CHEERS Report Generated: 2016-08-29 14:10:40 I I