Loading...
HomeMy WebLinkAbout1635 BASSWOOD AVE; ; CB153502; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 12-18-2015 Residential Permit Permit No: CB153502 Buildin~~ Inspection Request Line (760) 602-2725 Job Address: Permit Type: 1635 BASSWOOD AV CBAD RESDNTL Sub Type: RAD Lot#: 0 Constuction Type: 58 Reference #: Status: ISSUED Applied: 10/16/2015 Entered By: JMA Parcel No: Valuation: 2051306100 $75,231.00 Occupancy Group: # Dwelling Units: 0 0 Structure Type: Plan Approved: 12/18/2015 Issued: 12/18/2015 Bedrooms: Bathrooms: 0 Orig PC#: Inspect Area: Plan Check#: Project Title: BENSEN: 451 SF ADDITON OF NEW BEDROOM I ADD BAY WINDOW TO KITCHEN Applicant: BENSEN DANIEL&HEATHER 1635 BASSWOOD AVE CARLSBAD CA 92008 760-429-5586 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee $520.74 $0.00 $364.52 $62.02 $0.00 $9.78 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $4.00 $0.00 Owner: BENSEN DANIEL&HEATHER 1635 BASSWOOD AVE CARLSBAD CA 92008 Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (31 04193) License Tax ( 4304193) Traffic Impact Fee (31 05541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES Total Fees: $1,130.76 Total Payments to Date: $1,130.76 Balance Due: Inspector: FINAL A~PROVAL Date· . ("" .;._t, · /? . """""" Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $67.00 $46.00 $56.70 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1,130.76 $0.00 NOllCE: Please take NOTICE that approval of your prqect includes the "I!TfJCSition'' c:i fees, dedications, reservations, or other exactions hereafter rolectively referred to as "fees/exactions." You have 00 days from the date this pemit was issued to protest irrposition of these fees/exactions. If you protest them, you rrust fallON the protest procedures set forth in Government Cede Section 66020(a), ard file the protest and any other re::JUired infiJITTB!ion \Mth the Oty Manager for JXocessirg in acrordance \Mth Carlsbad M..Jnidpal Cede Section 3.32.030. Failure to tirrely fallON that JXored.ire \Mil bar any subsequent legal action to attack, review, set aside, void, or annul their irrposition. You are hereby FURn-ER NOTlRED that your ri(lht to protest the specified fees/exactions IXlES NOT APR. Y to water and sewer oonnection fees and capadty chan(les, nor plannirg, zoning, gradirg or other sinilar application JXocessirg or service fees in oonnection \Mth this project. NOR IXlES IT APR. Y to any fees/exactions of vvhch have 'ousl been ·vena NOllCE sinilar to this or as to which the statute of !irritations · ·see ired. City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 12-18-2015 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW150411 Job Address: Permit Type: Parcel No: Reference #: CB#: Project Title: Applicant: 1635 BASSWOOD AV CBAD SWPPP 2051306100 CB153502 BENSEN: 538 SF ADDITION BENSEN DANIEL&HEATHER 1635 BASSWOOD AVE CARLSBAD CA 92008 760-429-5586 Emergency Contact: JOE BARILLE 760-802-2307 SWPPP Plan Check SWPPP Inspections Additional Fees TOTAL PERMIT FEES Status: Lot#: 0 Applied: Entered By: Issued: Inspect Area: Tier: Priority: Owner: BENSEN DANIEL&HEATHER 1635 BASSWOOD AVE CARLSBAD CA 92008 ISSUED 10/16/2015 JMA 12/18/2015 1 M $54.00 $228.00 $0.00 $282.00 Total Fees: $282.00 Total Payments To Date: $282.00 Balance Due: l $0.00 'I THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING D ENGINEERING 0BU!LDING OFIRE 0HEALTH 0HAZMATIAPCD Cicyof Eluilding Permit Application Plan Check No. CB ( 5". 3 5 02 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value'~ q, 1 tf Lf Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit Carlsbad email: building@carlsbadca.gov www.carlsbadca.gov Date ;o. fro ·I C lswPPP tS-Lf-1 I JOB ADDRESS l {o ~ Bas&torool. Jk SUITE#/SPACE#/UNIT# IAPN zo5 -too -lD \ -00 CT/PROJECT # I LOT# I PHASE# I# OF UNITS I# BEDROOMS #BATHROOMS I TENANT BUSINESS NAME I CONSTR. TYPE I occ. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected A1•ea(s) 4 31.~1 $Ff .. "Bet 8' b' ~\.~ . . € fot>ffi1 . 4..-~1 ~~\; 6re-e ~r o Bet~ uJ ,'v)tlbw ,Acl~ 111{ sQ -rr ~ ~~ fJ /V''d.s"\etf BeJcmr~\f\ wii.)A')eline~-t-I DO. sv S0 Fr EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE lAIR CONDITIONING I FIRE SPRINKLERS YESO NO~ YES0Noi8J YESONo~ APPLICANT NAME H-ea::H 'B. Prinarv contact '\(1 ("' ;.0V) f:e .V'\ PROPERTY OWNER NAM6DtJJt{e/ cf. 1-k~ &v1~eJ'l ADDRESS I (o 35 1S asswo-uJ Av"e_ ADDRESS IIP3r;-·sassw~ Ave_ CITY~ STATE ZIP CITY L-Ml skx:d_ STATE c(1-oo~ lsloe<ol CA t'l'~& ~A PHONE 100· 42-"t.ss-t>t.P IF~-PHONE . , '"1(90,42-~, s-s-~(p IFAX ~ EMAIL . V\-e.a~~loe.J~tseA\_@(..:n~~lfle:td., C:hvlll"' EMAIL · \t1e~\Q£»L~-~ YVlai) . ~ DESIGN PROFESSIONAL coNTRACTOR Bus. NAME Po.et~G \{ :evJ ''BLLL \da;f ..s:' ADDRESS ADDRESS •• 3 C1vf ls.\0cd V1Uos;e_ Df. :i= f77 D'(J CITY STATE ZIP CITY Cail>loo,~ CJt ZIP 9.2-Df)~ PHONE I FAX PHONE '?t;_f;; l1 'S. '--1 -s 3]:, 2-I FAX EMAIL p~ci-h ·o11ew \ou l \defs ~ h.L+«ta) I. lfWlA I STATE uc. # STATE LIC.# ICLA~ I Cl72..3c~z_ l 0 '-/ 1s-1~1> (Sec. 7031.5 Busmess and Profess1ons Code. Any C1ty or County wh1ch requ1res a perm1t to construct, alter, Improve, demolish or repa1r any structure, pnor to 1ts Issuance, also reqUJres the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civii penalty of not more than five hundred dollars {$500}). Workers' Compensation Declaration: I hereby affirm under penalty of perjur; one of the following declarations: D I have and will maintain a certificate of consent to self-insurE! for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. Policy No. Expiration Date _________ _ hi ection need not be completed if the permit is for one hundred dollars ($1 00) or less. Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, as provided for in1 Section 3706 of the Labor code, interest and attorney's fees. JE5 CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor's License Law for the> following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered ior sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am excl~sively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement DYes 0No 2. I (have I have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work): JE5 PROPERTY OWNER SIGNATURE 0AGENT DATE I certifythatl have read the application and state that the above information is co;rectand that the information on the plans is accurate. I agree to comply with all City ordinances and State lav.s relating to building construction. I hereby authorize representative of the City of Cansbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolttion or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and beccme null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code) . . .--· ~APPLICANT'S DATE /b I pecti n List Permit#: CB153502 Type: RESDNTL RAD Date ~. __ _Inspection Item Inspector 05/26/2016 89 Final Combo 05/26/2016 89 Final Combo PD 04/22/2016 89 Final Combo PD 03/14/2016 17 Interior Lath/Drywall PD 03/14/2016 18 Exterior Lath/Drywall PD 03/11/2016 84 Rough Combo PD 03/10/2016 13 Shear Panels/HD's PD 03/09/2016 13 Shear Panels/HD's PD 03/09/2016 13 Shear Panels/HD's PD 01/21/2016 15 Roof/Reroof PD 12/21/2015 11 Ftg/Foundation/Piers PD 12/21/2015 21 Underground/Under Floor PD Act Rl AP CA AP AP AP AP co NR AP AP AP BENSEN: 451 SF ADDITON OF NEW BEDROOM I ADD BAY WINDOW TO KITC Comments City of Carlsbad SPECIAL INSPECTION AGREEMENT B-45 Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural o'bservation and construction material testing. Project/Permit: 15-3S 02- A. THIS SECTION MUST BE COMPLETED IBY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder CJ. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print}-) _ _,_\,~--'--"'.eL=-t=k'-'-'---''\t'-Q""';"-( ________________ t3"""'--'e ..... ,.,""-V\---'-""fJZ=~'-'--='----- (First) Mailing Address: \ \e3s-Bt;t..S5W ocd.. IV£ Email· het1:1\ner \oeilSBtll @_()) fflt;l , tQvV\ "" (M.I.) <Lastl '1' .. ""' L: " q -~s-q. l '' Phone: tv~· l t:-, S -o v:; I am: )ii'Property Owner OProperty Owner's Agent of Record OArchitect of Record OEngineer of Record State of California Registration Numbe · Expiration Date: _______ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signature:~;.~-Date: /ojdvj;.!>- B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder I owner-builder. Contractor's Company Name:_Pcae:lh· c ~ \} i f<.AJ ~BLLll der .S Please check if you are Owner-Builder CJ Name: (Please print) _ _,.j"""OS=-',=-' _...(-T~'i'-'-:'--""-\, _____________ 1)-"'' '-"'Ci""'{f"-"-'\ \,_,\.__,e__-"'"-----------~st) (M.I.) (Last) Mailing Address: 3oo Caf~>byL VUk~~e !:>r. :.j: \]] 1 Q-:sJtSia<c,CU\ J Email: pau '-h~;...~ \ 6t\l \oJ~ \deA'S @_ btrbYXI .i ( • CotV' State of California Contractor's License Number: '1511-\ 5"' Phone: lto. Lf~4, 333 2- Expiration Date: ~ /Je {tr,.:, ~ I • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and tlhe distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final inspection. Signature: : · {7 tU.J Date: ___,_(tJ~/_3----"_,-+J-'-fL~---r ' B-45 Page 1 of 1 Rev. 08/11 DATE: 11/03/15 JURISDICTION: Carlsbad PLAN CHECK NO.: 15-3502 EsGil Corporation In (]'artnersfiip witfi qovernment for CBuiCaing Safety SET: II PROJECT ADDRESS: 1635 Basswoood Ave. PROJECT NAME: Room Addlitions for Bensen Residence 0 APPLICANT 0 JURIS. 0 PLAN REVIEWER 0 FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted hen~with have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Telephone#: (by: ) Email: Telephone Fax In Person 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 DATE: 10/26/15 JURISDICTION: Carlsbad PLAN CHECK NO.: 15-3502 EsGil Corporation In CFartnersfiip witfi qovernment for CBui(tfing Safety SET: I PROJECT ADDRESS: 1635 Basswoood Ave. PROJECT NAME: Room Additions for Bensen Residence Q APPLICANT ~RIS. Q PLAN REVIEWER Q FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. cg] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. cg] The applicant's copy of the check list has been sent to: Heather Bensen D EsGil Corporation staff did not advise the applicant that the plan check has been completed. ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Heather Bensen Telephone#: (760) 429-5586 ,;Date coptacted: I D/?;J--fbyYfu_ Email: heatherbensen@gmail.com ~Mail ..! Telephone Fax In Person D REMARKS: By: Ray Fuller Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 PC 10/19/15 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ' Carlsbad 15-3502 10/26/15 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 15-3502 JURISDICTION: Carlsbad PROJECT ADDRESS: 16a5 Basswoood Ave. FLOOR AREA: Additions 552 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 10/16/15 DATE INITIAL PLAN REVIEW COMPLETED: 10/26/15 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: 10ft per CRC DATE PLANS RECEIVED BY ESGIL CORPORATION: 10/19/15 PLAN REVIEWER: Ray Fuller This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by th~~ Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. 'Carlsbad 15-3502 10/26/15 1. Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Verify final sets of architectural sheets will be signed by designer and that the structural sheets and any new calculations will be stamped and signed by engineer of record also. Owner/designer to sign the CF1-R forms. 3. The City of Carlsbad requires a soils report when room addition(s) exceed 500 sq ft. Provide a copy of the project soil report. The report shall include foundation design recommendations based on the engineer's findings and shall comply with Section R401.4. Please verify report is current (as most reports expire after one to three years). Provide copies of any updated reports and verify soils report addresses current code parameters (IBC and not UBC) etc. 4. If applies: The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: The building pad was prepared in accordance with the soils report, The utility trenches have been properly backfilled and compacted, and The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." 5. Provide a letter from the soils engineer confirming that the foundation plan, and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report) . 6. If applies: Where expansive or collapsible soils are known to exit, show on the plans a controlled method of water disposal from roofs that will collect and discharge roof drainage to the ground surface at least 5' from the foundation. Section R801.~3 7. Show or note that exterior doors may swing outward only if the exterior landing is not more than 1% inches lower than the top of the threshold. R311.3.1 ' Carlsbad 15-3502 10/26/15 8. Please clearly iindicate on the cover sheet of the plans whether the existing residence has a fire sprinkler system installed or not and or if proposing to be fire sprinklered. If existing structure is fire sprinklered then provide a note stating that any additions/alterations will also be provided with an automatic residential fire sprinkler system. Section R313.2. 9. Please clearly indicate on the cover sheet of the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994 please add the following note on the cover sheet of the plans " All existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407 1 0. Electrical plan did not address the lighting and required exhaust fan in bathroom on sheet 1 0? Bathrooms shall be mechanically ventilated in accordance with the mechanical code (openable windows are no longer acceptable). In bathrooms, at least one fixture shall be high efficacy and all remaining fixtures shall be high efficacy or be controlled by a vacancy sensor. 11. Recheck plans for tempered window locations i.e. within 2 ft of exterior doors, shower/tub areas within 5 ft radius of tubs (unless 5 ft above). See 2030 at bath as within !:i ft radius the tub ands 2040 adjacent to 3068 patio door. • CITY of CARLSBAD REQUIREMENTS 12. All new residential buildings, including additions, require a soils report. An update letter is required if the report is more than 3 years old. If a room addition is less than 500 sq. ft. in area and only one story, then a soils report is not required. The maximum allowable soil bearing value used in any design must be 1000 psf for this exception. 13. If special inspection is required, the designer shall complete the city's "Special Inspection Agreement". • Note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, n~ote or detail number, calculation page, etc. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have chan~1es been made to the plans not resulting from this correction list? Please indicate: Yes ( ) No ( ) • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ray Fuller at Esgil Corporation. Thank you. ' Carlsbad 15-3502 10/26/15 [DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 15-3502 PREPARED BY: Ray Full1er DATE: 10/26/15 BUILDING ADDRESS: 16:35 Basswoood Ave. BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION VB BUILDING AREAJ Valuation PORTION (Sq. Ft.) Multiplier Additions t)52 166.81 Air Conditioning !)52 5.31 Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance --------------~l Bldg. Permit Fee by Ordinance ~-~,_j ~-n C_h_ec~ee by Ordin_an_ce__ ~J Type of Review: 0 Complete Review 0 Repetitive Fee __ ··•] Repeats 0 Other 0 Hourly EsGil Fee Reg. VALUE Mod. 0 Structural Only 1----------11 H r @ • ($) 92,079 2,931 95,010 $604.88j $393.171 A $338.731 Comments: ___ _ In additionto the. above fee, an add.itibnal fee of $:43 is :due {,.5-hour @ $86/hr.) for the CaiGreenreview. Sheet 1 of 1 macvalue.doc + City of Carlsbad PLAN CHECK REVIEW TRANSMITTAL DATE: 10~26~15 PROJECT NA,ME: BENSEN RESIDENCE ADDITION PLAN CHECK NO: SET#: 1 ADDRESS: 1635 AVE. VALUATION: SC:OPE OF WORK: ADDITION 551 FT. Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov PROJECT ID:CB153502 APN: 205-130-61 This plan check review is complete and has been APPROVED by: D LAND DEVELOPMENT ENGINEERING DIVISION Final Inspection by Construction Management & Inspection Division is required: Yes No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached chec~(list. Please resubmit amended plans as required. Plan Check Comments have been sent to: Linda Ontiveros 760-602-2773 VaiRay Nelson 760-602-27 41 Remarks: BENSEN RESIDENCE ADDITION PLAN CHECK NO# 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: North arrow i Existing & proposed structures ' Existing street improvements Property lines (show all dimensions) Easements Right-of-way width & adjacent streets Show on site plan: Driveway widths : Existing or proposed sewer lateral Existing or proposed water service Submit on signed approved plans: DWG No. Drainage patterns and proposed site elevations. Show all high points. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". Existing & proposed slopes and topography :Size, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: Site address Assessor's parcel number i Legal de1scription/lot number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showin~J square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show atll existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No.: LOT #7, MAl~ #5757 Subdivision/Tract: SANDALEWOOD DALE Reference No(s): E-36 Page 2 of 6 REV 6/01112 BENSEN RESIDENCE ADDITION PLAN CHECK NO# E-36 5. GRADING PIERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. jlnadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" Grading Permit required. NOTE: The grading permit must be issued and rough grading approval obtained prior to issuance of a building permit. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector The inspector will then provide the engineering counter with a release for the building permit. No grading permit required. Minor Grading Permit required. See additional comments for project-specific requirements. 6. MISCELLANEOUS PERMITS . RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work ·adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. :., Right-o1f-way permit required for: Page 4 of 6 REV 6/01/12 E-36 RESIDENCE ADDITION PlAN CHECK NO# 7. STORM WATER Construction Compliance Proje:ct Threat Assessment Form complete. Enclosed Project Threat Assessment Form incomplete. Requires Tier 1 Storm Water Pollution Prevention Plan (E-29). Please complete attached form and return ) Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Develo·pment (SUSMP) Compliance Storm Water Standards Questionnaire. Proj1act is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. Indicate areas of impervious surfaces (patios,walkway, etc. ) and pervious areas (landscaping). ·j Proj1act needs to incorporate low impact development strategies throughout in one or more of the following ways: j Rainwater harvesting (rain barrels or cistern) Vegetated Roof Sic-retentions cell/rain garden : Pervious pavernenUpavers Flow-through planter/vegetated or rock drip line ' Vegetated swales or rock infiltration swales Downspouts disconnect and discharge over landscape Other: Page 5 of 6 REV 6/01/12 RESIDENCE ADDITION PlAN CHECK NO# Attachments: E-36 8. WATER METER REVIEW 9. FEES Domestic (potable) Use What size meter is required? Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. For residential units the minimum size meter shall be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger than one quarter (1/4) acre where the meter size shall be%". Required fees have been entered in building permit. Drainage fee applicable Added square feet Added square footage in last two years? Permit No. Permit No. Project built after 1980 Impervious surface > 50% Impact unconstructed facility yes yes yes yes no no no Fire sprinklers required Upgrade No fees required yes no (is addition over 150' from center line) ino 10. ADDITIONAL COMMENTS Engineering Application Storm Water Form Right-of-Way Application/Info. Reference Documents Page 6 of 6 REV 6/01/12 STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP E-29 STORM WATER COMPLIANCE CERTIFICATE V' My project is not in a category of permit types exempt from the Construction SWPPP requirements V' My project is not located inside or within 200 feet of an environmentally sensitive area with a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). V' My project does not require a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code) V' My project will not result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets one or more of the additional following criteria: • located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or, • disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or • disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or • construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS. I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSBAD. ~..e.cd'ra£ ·~...e.,V\ 9(_;{'1 OWNER(S)/9WNER'S AGENT NAME (PRINT) tobta/1~ DAfE I OWNER(S)/OWNER'S AGENT NAME (SIGNATURE) E-29 STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPS WHEN RAIN IS EMINENT. 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 5. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. SPECIAL NOTES Page 1 of 3 Development Services land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov PROJECT INFORMATION Site Address: Uo3>5 'Bc?s.Sih'Vut Ave.. Assessor's Parcel Number: 205-1'30-((l \ ~ProjectiD: C0\5 ~502 ~ Construction Permit No.0W \ 504 \ l Estimated Construction Start Date ____ _ Project Duration Months o•.J" Emergency Contact: Name: _J~ lS~;'l (,q 24 hour Phone: I ~ 0 -eo 2.-23 0 7 Perceived Threat to Storm Water Quality ~Medium D Low If medium box is checked, must attach a site plan 1 ~;-;;~;~~;~P~~r~~~~~a~e:~·~o:k area and location 1 For City Use Only CITY OF CARLSBAD STANDARD TIER 1 SWPPP c_(,. Approved By:--------- Date: [ 0 -2 ~ -l :S REV 4/30/10 Erosion Control Tracking Non-Storm Water Waste Management and Materials Sediment Control BMPs Control BMPs BMPs Management BMPs Pollution Control BMPs c c c "E "E 0 0 0 "'C ~ Ql "'C Ql c u t5 c Ol E c E "'C c "* ttl 2 2 0 '6 Ol c. ttl Ql c 2 Vl ~ E Ql ~ .E ·:; 1!"-ttl Ol (i) u;Vl iii c Ol Vl 2 2 Ol "'CQ) 'E ttl c Best Management Practice c c-c. Ql c ·;:: c c Vl c ~ ~ 0" Ql c 0 ~ Vl oi:S :c ttl ttl Vl ~ CD ·a. ro -0 Ql 0 Ql ~ UJ .2: ttl ~ ~ Vl :;: Ql (BMP) Description ~ Vl u c I-E Ol alg' CD c u~ (.) Vl !j "'C Cii Vl 2 2 Ql(IJ Vl "iii c ~~ c c Ql Vl Ql ""5 -~ Ql ttl ttl "'C>. 0 ::::> > Vl ~ ~Ql "E 0 :;: ·-0 Vl ~-~ .!!1 ~ ~ ~ 2 u 0 CD (IJE Ol ~ 0 Ql ttl '2 -~ IJ i~ 0 OOl 0 c Ql 0::: ttl 0:;:::: N Vl ~~ Ql (ij ·a. "E ttl Ql E -" Cii -~ .c E ~ :=tl) :0 ·;:: 2 "'C .s=c Ql lL u (i) > Ql ~ "'C :E~ $~ ~! u c * -" "'C ttl u 0 0 t::: ·-c. '6 Ql ~ u c 00 .cttl ttl ·-ttl u ~~ c Ql ~ ttl~ 0 -Ql .s= .c ~ ttl ttlO) c75& ~a: 0 -'=w c7l ~~ 0 -ttl -~ -c ~u 0 UJO 1i5 en (/) (.) u:: 0 (/)> (/) (/)0... (/)_ a.. 2 (.)..; CASQA Designation ~ I'-co Cl) ~ ~ '? -.r ll) (0 I'-co 0 ~ ~ ~ ("") I'-co ~ ~ ("") ""i "? (0 co u u u ~ uJ uJ uJ uJ uJ uJ ~ r:r. ch ch ch ch ~ ~ ~ ~ u UJ uJ 0::: 2 2 2 UJ UJ UJ (/) (/) (/) (/) (/) (/) (/) I-I-z z z z s s s s s s s Construction Activity UJ (/) Grading/Soil Disturbance I~ ;;>< Trenching/Excavation IX.. Stockpiling 1.~ Drilling/Boring Concrete/Asphalt Saw cutting Concrete flatwork IV Paving Conduit/Pipe Installation Stucco/Mortar Work lX'" Waste Disposal Staging/Lay Down Area Equipment Maintenance and Fueling Hazardous Substance Use/Storage Dewatering Site Access Across Dirt Other (list): I I I I I I I I I I I I I I I I I I -___ _l_ I I I I _ _ __j______l______ I I I ___ l__j I I I I I I II I I I I I I I II I I I I I --1 I I I I -1 I I I --I I Instructions: Begin by reviewing the list of construction activities and checking the box to the left of any activity that will occur during the proposed construction. Add any other activity descriptions in the blank activity description boxes provided for that purpose and place a check in the box immediately to the left of the added activity description. For each activity descrribed, pick one or more best management practices (BMPs) from the list located along the top of the form. Then place an X in the box at the place where the activity row intersects with the BMP column. Do this for each activity that was checked off and for each of the selected BMPs selected from the list. For Example-If the project includes site access across dirt, then check the box to the left of "Site Access Across Dirt". Then review the list for something that applies such as "Stabilized Construction Ingress/Egress" under Tracking Control. Follow along the "Site Access Across Dirt" row until you get to the "Stabilized Construction Ingress/Egress" column and place an X in the box where the two meet. As another example say the project included a stockpile that you intend to cover with a plastic sheet. Since plastic sheeting is not on the list of BMPs, then write in "Cover with Plastic" in the blank column under the heading Erosion Control BMPs. Then place an X in the box where the "Stockpiling" row intersects the new "Cover with Plastic" column. To learn more about what each BMP description means, you may wish to review the BMP Reference Handout prepared to assist applicants in the selection of appropriate Best Management Practice measures. The reference also explains the California Stormwater Quality Association (CASQA) designation and how to apply the various selected BMPs to a project. E-29 Page 2 of 3 REV 4/30/10 '·'<~ C !TY 0 F CARLSBAD STORM WATER COMPLIANCE ASSESSMENT B-24 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov I am applying to the City of Carlsbad for the following type(s) of construction permit: i( Building Permit 0 Right-of-Way Permit 0 My project is categorically EXEMPT from the requirement to pre~pare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types: Patio/Deck Photo Voltaic Re-Roofing Sign Spa-Factory Sprinkler Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Water Discharge Project Storm Water Threat Assessment Criteria* No Threat Assessment Criteria D My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level. My project does not mee:t any of the High, Moderate or Low Threat criteria described below. Tier 1 -Low Threat Assessment Criteria )( My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria: • Results in some soil disturbance; and/or • Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). Tier 2 -Moderate Threat Assessment Criteria D My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: • Located within 200 fe,at of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is loca1ted along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). Tier 3 -Significant Threat Assessment Criteria 0 My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or D My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or, 0 My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). I certify to the best of my knowledge that the above checked statements are true and correct. I understand and acknowledge that even though this p•roject does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check abe~ve comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards. Project Address: Assessor Parcel No. 'The Cily Engineer may aulhorize minor variances from the Storm Water Threat Assessment Criteria in special circumslances where it can be shown that a lesser or higher Construction SVVPPP Tier Level is warranted. B-24 I {" 3 §.-'Bccs.Svvot:d Av--e_ Owner!Owner's Authorized Agent Name: t\-ect\\r\Qr ''B-eAt\ se.,;0 Owner/Owner's Authorized Agent Signature: cJ..J/1S __ .... City Concurrence: By: Date: lA YES Cl NO CG-(()-lb-15 Page 1 of 1 Title: Date: lojltpjp Project ID: CB 15·5~o.;t. Rev.03/09 ''""" . ,, ~-CITY OF RLSB STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov To address post-development pollutants that may be generated from development projects, the City requires that new development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMP's) into the project design per the City's Standard Urban Stormwater Management Plan (SUSMP). To view the SUSMP, refer to the Engineering Standards (Volume 4, Chapter 2) at www.carlsbadca.gov/standards. Initially this questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to 'Standard Stormwater Requirements' or be subject to additional criteria called 'Priority Development Project Requirements'. Many aspects of project site design are dependent upon the storm water standards applied to a project. Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by you, this will result in the return of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the City. If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, please seek assistance from Land Development Engineering staff. A separate completed and signed questionnaire must be submitted for each new development application submission. Only one completed and signed questionnaire is relquired when multiple development applications for the same project are submitted concurrently. In addition to this questionnaire, you must also complete, sign and submit a Project Threat Assessment Form with construction permits for the project. Please start by completing Step 1 and follow the instructions. When completed, sign the form at the end and submit this with your application to the city. s your project new or paved bicycle lanes or trails that meet the following criteria: (1) Designed and constructed to direct storm water runoff to adjacent vegetated areas, or other non-erodible permeable areas; OR (2) designed and constructed to be hydraulically disconnected from paved streets or roads; OR (3) designed and constructed with permeable pavements or surfaces in ::.r.t~nnrt::.rlr.Fl with USEPA Green ance? 2. project LIMITED TO retrofitting or redeveloping existing paved al or roads that are and constructed in accordance with the US EPA Green YES NO If you answered "yes" to one or more of the above questions, then your project is NOT a priority development project and therefore is NOT subject to the storm water criteria required for priority development projects. Go to step 4, mark the last box stating "my project does not meet PDP requiremtmts" and complete applicant information. answered "no" to both 2. E-34 Page 1 of 3 Effective 6/27/13 C !TY 0 F STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov determine if your project is a priority development project, please answer the following questions: 1. Is your project a new development that creates 10,000 square feet or more of impervious surfaces collectively over the entire project site? This includes commercial, industrial, residential, mixed-use, and public nrn,tP.r.r.c:: on 2. Is your project creating or replacing 5,000 square feet or more of impervious surface collectively over the entire project site on an existing site of 10,000 square feet or more of impervious surface? This includes commercial, ~d 00 ~~ 3. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface collectively over the entire project site and supports a restaurant? A restaurant is a facility that sells prepared foods and drinks for consumption, including stationary lunch counters and refreshment stands selling prepared foods and drinks for immediate 4. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface collectively over the entire project si1te and supports a hillside development project? A hillside development project includes development on any natural slope that is twenty-five percent or greater. 5. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface collectively over the entire project site and supports a parking lot. A parking lot is a land area or facility for the of motor vehicles used for business or for commerce. 6. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface collectively over the entire project site and supports a street, road, highway freeway or driveway? A street, road, highway, freeway or driveway is any paved impervious surface used for the transportation of rrJTI:Vt:'IR.'< and other Vehicles. 7. Is your project a new or redevelopment project that creates or replaces 2,500 square feet or more of impervious surface collectively ove~r the entire site, and discharges directly to an Environmentally Sensitive Area (ESA)? "Discharging Directly to" includes flow that is conveyed overland a distance of 200 feet or less from the project to the ESA, or conveyed in a pipe or open channel any distance as an isolated flow from the to the ESA .e. not with flows from * 8. Is your project a new development that supports an automotive repair shop? An automotive repair shop is a facility that is categorized in any one of the following Standard Industrial Classification (SIC) codes: 5013, 501 5541 or 7536-7539. 9. Is your project a new development that supports a retail gasoline outlet (RGO)? This category includes RGO's that meet the following criteria: (a) 5,000 square feet or more or (b) a project Average Daily Traffic (ADT) of 100 or more vehicles 10.1s your project a new or redevelopment project that results in the disturbance of one or more acres of land and are expected to generate pollutants post construction? Pacific Ocean 2,500 square feet or more of i surface on the than 10%? •XJ you answered "yes" to one or more of the above questions, you ARE a priority development project and are therefore subject to plementing structural Best Management Practices (BMP's) in addition to implementing Standard Storm Water Requirements such source control and low impact dev13lopment BMP's. A Storm Water Management Plan (SWMP) must be submitted with your ) for development. Go to step 3 for redevelopment projects. For new projects, go to step 4 at the end of this estionnaire, check the "my project: meets PDP requirements" box and complete applicant information. you answered "no" to all of the above questions, you ARE NOT a priority development project and are therefore subject lementing only Standard Storm Water Requirements such as source control and low impact development BMP's required for projects. A Storm Water Management Plan (SWMP) is not required with your application(s) for development. Go to the end of this questionnaire, check the "my project does not meet PDP requirements" box and complete ap,pm;anlll rmation. E-34 Page 2 of 3 Effective 6/27113 STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ent of impervious surface in an amount of less than If you answered "yes," the structural BMP's required for Priority Development Projects apply only to the creation or replacement impervious surface and not the entire development. Go to step 4, check the "my project meets PDP requirements" box and complete applicant information. If you answered "no," the structural BMP's required for Priority Development Projects apply to the entire development. Go to step 4, check the meets PDP uirements" box and information. D My project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stormwater criteria per the SUSMP and I understand I must prepare a Storm Water Management Plan for submittal at time of application. I understand flow control (hydromodification) requirements may apply to my project. Refer to SUSMP for details. My project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per the SUSMP. As part of these requirements, I will incorporate low impact development strategies throughout my project. Applicant Information and Signature Box Accessor's Parcel Number(s): Applicant ~m!:-, 1 11 •.• h r B =u..;t"v \IJ..)\ \3eN\ S ~:_.;'(\. Applicant Title: Date: This Box for City Use Only City Concurrence: I YES I NO I ;< I By: e-t- Date: I o -~ b ·/5 Project ID: (_~IS-350~ • Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies; areas designated as Areas of Special Biological! Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their quivalent under the Multi Species Conservation Program within the Cities and County of San Diego; and any other equivalent environmentally sensitive areas which have been identified by the Copermittees. E-34 Page 3 of 3 Effective 6/27113 PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 10/19/15 PROJECT NAME: ADDITION PROJECT ID: Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.eov PLAN CHECK NO: CB15~~502 SET#: ADDRESS: 1635 BASSWOOD AV APN: [g] This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required Yes ~No You may also have corre~ctions from one or more divisions listed below. Approval from these divisions may be required to the of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: HEATHERBENSEN@GMAIL.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 D Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov Veronica Morones 760-602-4619 Veronica.Morones@carlsbadca.gov ENGINEERING 760-602-2750 'FIRE PREVENTION 760~602-4665 Remarks: SETBACKS: FY=20' (20' REQ'D) SY=7.2' & 10' (7.1' & 10' REQ'D) RY=16.1' (14.2' REQ"D) COVERAGE=30.5% (40% MAX)HEIGHT=17.5' (30' MAX) PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET B-18 Project,Address: lt.D'&5 ~~~'NODO Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Building@carlsbadca.gov Permit No.:C,6 \ 5"311502_ Information provided below refers to wor~ being done on the above mentioned permit only. This form must be completed and returned to the Building Division before the permit can be issued. Building Dept. Fax: (760) 602-8558 Number of new or re!located fixtures, traps, or floor drains ....................................................... ~ New building sewer lline? ........ ~;o£.~ .. t:P. ... :c.6.l.?.:bM ...................... Yes __ No __ Number of new roof drains? ............................................................................................................... __Q__ Install/alter water line? ......................................................................................................................... ll.fO Number of new wat1er heaters? ....................................................................................................... .. (') Number of new, relocated or replaced gas outlets? .................................................................... _Q_ Number of new hose: bibs?.................................................................................................................. \ Residential Permits;: New/expanded servke: Number of new amps: _______ _ ,. Minor Remodel only;-Yes-X--No Commercial/Industrial: Tenant Improvement: Number of existing amps involved in this project: Number of new amps involved in this project: New Construdion: Amps per Panel: Single Phase ............................................................... Number of new amperes _______ _ Three Phase ................................................................. Number of new amperes _______ _ Three Phase 480 ........................................................ Number of new amperes _______ _ Number of new furnaces, A/C, or heat pumps? ............................................................................ _Q__ New or relocated duct worl::l? .......................................................................... Yes ,/ No __ _ Number of new fireplaces? ................................................................................................................. _Q__ Number of new exhaust fans? ............................................................................................................ j__ Relocate/install vent:? ............................................................................................................................ yt$,~} Number of new exhaust hoods? ........................................................................................................ _Q__ Number of new boilers or compressors? ........................................................... Number of HP {) B-18 Page 1 of 1 Rev. 03/09 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 12-18-2015 Plan Check Revision Permit No:PCR15132 Buildin~~ Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC#: 1635 BASSWOOD AV CBAD PCR 2051306100 Lot#: 0 $0.00 Construction Type: 58 Status: Applied: Entered By: Plan Approved: Issued: Project Title: BENSON: DECREASE SIZE OF ADD. Inspect Area: REMOVE ADDITION TO MASTER BED (DECREASE OF 87 SF) Applicant: BENSEN DANIEL&HEATHER 1635 BASSWOOD AVE CARLSBAD CA 92008 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees Total Fees: $107.50 Inspector: Owner: BENSEN DANIEL&HEATHER 1635 BASSWOOD AVE CARLSBAD CA 92008 $107.50 $0.00 $0.00 Total Payments To Date: $107.50 Balance Due: FINAL APPROVAL Date: Clearance: ISSUED 11/30/2015 SLE 12/18/2015 12/18/2015 $0.00 NOTl CE: Please take NOTlCE that approval of your project indudes the "Imposition" of fees, dedications, reservations, <ir other exactions hereafter oollectively referred to as "fees/exactions." You have 90 days from the date this pemit was issued to protest imposition of these fees/exactions. If you protest them, you rrust follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information wth the Oty rv1anager for processing in a=rdance wth Carlsbad Munidpal Code Section 3.32.030. Failure to tirrelyfollowthat procedure wll bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby AJRTHER NOTIFIED that your rigl1t to protest the spedfied fees! exactions DOES NOT APPLY to water and 5e'Mlr connection fees and capadty changes, nor planning, zoning, grading or other sirrilar application processing or service fees in connection wth this project. NOR DOES IT APPLY to any fees/exactions of \Mlich vou have oreviousl been c iven a NOTlCE sirrilar to this or as to \Mlich the statute of !irritations has__Q[eviou!lk other\Mse exoired. PLAN CHECK REVISION APPLICATION B-15 Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Plan Check Revision No. f}2g t 5132.,; Project Address It~; 35 Bt? st::urr:cl /4v~ Original Plan Check No. Cb \J:S 3502.. Date II /Jcju;- Contact J ~e Ba yi I( e Ph ']t.4). gvJ '• <~ 3o 7 Fax ________ _ 17 . I". ' , L r , I .I ,.,. c £.' L ,.,h. . I II II;~ Email rCt(l ~Lie\) ltl.'\.l l-\. l G\eA J e n (;Jt'Y)t:tl I t_('l/h Contact Address ill ~7~ 6a s,s c Unr.>c( Av~ Gene~IScope~Wo~ ~~~~l~d~e~I~UH~~~~l~t~'l-4~~=e~th~~~1~~----------------~ Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: ~ Plans D Calculations D Soils D Energy D Other ___________ _ 2. Describe revisions in detail \Z ef11 r \.! t.:t t r:~ Ntt1 S'te( be&Jnml"Jl ocf &i~h 't:rvt ore~\ ou'? ~ddmc)f\ -= '538 6f. \ odd .. tnew\ 45\4. ~'~a - 5. 6. Does this revision, in any way, alter the exterior of the project? Does this revision add AI\IY new floor area(s)? 7. Does this revision affect any fire related issues? 8. Is this a complete set? ,.-.. ~ Yes D No £5' signature -~:,""'l·/···z.·····/ ~~~ ....... «····"'····-------· ··· t '"j {;,,.__~.~·· DYes DYes 3. List page(s) where each revision is shown aU ~Yes [2] No r8J No 4. List revised sheets that replace existing sheets eLl{ D No 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 7 60-602-2719 Fax: 7 60-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov EsGil Corporation ln (]!artnersliip witli qovernment for c.BuiUing Safety DATE: 12/18/15 JURISDICTION: Carlsbad PLAN CHECK NO.: PCR15-132 (15-3502) PROJECT ADDRESS: 1635 Basswoood Ave. SET: II PROJECT NAME: Plan Change (Delete Master Bedroom Extension) for Bensen I:8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herE~with have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: I:8J EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted:--r-...[) Telephone#: Date contacted:....--(~) Email: Mail Telephone Fax In Person [8 REMARKS: Applicant provided EsGil with three sets of revised Truss layout and the T-24 sheet. Owner set was slipped sheeted and set I became set II. Enclosed sheets to done with set(s) at the City. Previous approved City Sets sent back . By: Ray Fuller Enclosures: LOG EsGil Corporation D GA D EJ D MB D PC (P) 12/17/15 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In (}?artnersliip witfi government for (]Jui{tfing Safety DATE: 12/09/15 JURISDICTION: Carlsbad PLAN CHECK NO.: PCR15-1a2 (15-3502) PROJECT ADDRESS: 1635 Basswoood Ave. SET: I ~PLICANT ~ ~~RIS. D PLAN REVIEWER D FILE PROJECT NAME: Plan ChanJ!~e (Delete Master Bedroom Extension) for Bensen D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. C2J The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. C2J The applicant's copy of the check list has been sent to: Joe Barille D EsGil Corporation staff didl not advise the applicant that the plan check has been completed. C2J EsGil Corporation staff didl advise the applicant that the plan check has been completed. Person contacted: Joe Barille Telephone#: (760) 802-2307 /-.-Date:Jcantacted:\'1/{ 4 (b~c...y Email: pacificviewbuilders@hotmail.com k:Avlail Telephone Fax In Person D REMARKS: By: Ray Fuller Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 PC 12/10/15 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 'Carlsbad PCR15-132 (15-3502) 12/09/15 PLAN REVIEW CORRECTION LIST SINIGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: PCR15-132 (15-3502) JURISDICTION: Carlsbad PROJECT ADDRESS: 1635 Basswoood Ave. FLOOR AREA: Additions ~ 437 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 10/16/15 DATE INITIAL PLAN REVIIEW COMPLETED: 12/09/1l5 FOREWORD (PLEASE R:EAD): STORIES: 1 HEIGHT: 10 ft per CRC DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/10/15 PLAN REVIEWER: Ray Fuller This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad PCR15-132 (15-3502) 12/09/15 1. Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Verify final sets of architectural sheets will be signed by designer and that the structural sheets and any new calculations will be stamped and signed by engineer of record also. 3. Please provide revise energy calculations reflecting proposed change. Owner/designer to sign the CF1-R forms 4. Provide revise truss calculations deleting master bedroom room addtion aswell as revising T sheet on plans. • Note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indiicate: Yes ( ) No ( ) • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ray Fuller at Esgil Corporation. Thank you. Carlsbad PCR15-132 (15~-3502) 12/09/15 [DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Ray Fuller PLAN CHECK NO.: PCR15-132 (15-3502) DATE: 12/09/15 BUILDING ADDRESS: 16:3~5 Basswoood Ave. BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION VB BUILDING AREA J Valuation Reg. VALUE PORTION (Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance ___ , ___ , __ , ___ , ' _____ ,,_, ______ ] Plan Check Fee by Ordinance ..-j -~·----···------~----""""""*"' Type of Review: 0 Complete Review 0 Structural Only 0 Repetitive Fee _ ... J Repeats * Based on hourly rate Comments: 0 Other 0 Hourly EsGil Fee 11Hr.@ * ======$=8=6=.0:0 ($) $107.501 A $86.001 Sheet 1 of 1 macvalue.doc + PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 12/1/15 PROJE~CT NAME: ADDITION PROJECT ID: Development Services Planning Division 1635 Faraday Avenue {760) 602-4610 www.carlsbadca.rmv PLAN CHECK NO: PCR15132 SET#: ADDRESS: 1635 BASSWOOD AV APN: ~ This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required 0 Yes tz1 No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checkJist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: HEATHERBENSEN@GMAIL.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 D Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov [Z;J Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov D Veronica Morones 760-602-4619 Veronica.Morones@carlsbadca.gov ENGINEERING. 760-602-2750 760-602-2773 Unda.Ontiyeros@carlsb<!dca.gov FIRE PREVENTION 760-602-4665 760-602-4664 Remarks: SETBACKS: FY=20' (20' REQ'D) SY=7.2' & 10' (7.1' & 10' REQ'D) RY=16.1' (14.2' REQ'[)) COVERAGE=30.5% (40% MAX) HEIGHT=17.5' (30' MAX)