HomeMy WebLinkAbout1635 FARADAY AVE; ; CB984150; Structural CalculationsFirouzi
Consulting
Engineers, Inc.
a structural analysis end design company
STRUCTURAL CALCULATIONS
PROJECT NAME:
REVISED DATE:
LOT 106
DECEMBER 15,1998
ENGINEER OF RECORD: FIROUZI CONSULT
TABLE OF CONTENTS
Design Loads
Design Values
Vertical Design
Tilt-up walls
Foundation Design
Lateral Design
Page 17 - 49
Page 50 - 58
Page 59 - 9 1
16959 Bemardo Center Drive, Suite 201, San Diego, CA 92128 (619)485-6227 (6 4
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 92128
16559 Bernard0 Center Drive, Suite 201
Phone (619) 4858227, Fax (619) 4856x)l
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page 1
DESIGN LOADS
Roof Beams & Purlins
Above Warehouse: Dead Load
Above Office: Dead Load
Roof Sub-purlins Dead Load
Roof Members Live Load
Floor Members Office
Light Storage
Heavy Storage
Roofing
Framing
Plywood
Insulation
Misc
TOTAL
Roofing
Framing
Plywood
Insulation
Ceiling
Misc
TOTAL
Roofing
Framing
Plywood
Insulation
Misc
TOTAL
0 - 200 sq. fl
Over 600 sq. ft.
Dead Load
Partition Load
Live Load
Concentrated Load
Dead Load
Live Load
Concentrated Load
Dead Load
Live Load
Concentrated Load
201 - 600 Sq. fl
6.0 psf
3.5
1.5
0.5
1.5
13.0 psf
6.0 psf
3.5
1.5
0.5
2.0
1.5
15.0 psf
6.0 psf
1.5
1.5
0.5
1.5
11.0 psf
20 psf
12 psf
45 psf
20 psf
80 psf
per usage
45 psf
125 psf
per usage
45 psf
250 psf
per usage
16 psf
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego. California 92128
16959 Bemardo Center Drive. Suite 201
Phone (61 9) 4856227, Fax (61 9) -1
Project: Lot 106 Redesign
Job# 98244 By:
Date: Nov '98 Paae 2 "
DESIGN VALUES
WOOD MEMBERS
DOUGLAS FIR-LARCH
2" to 4" thick, 2" and wider
No. I Fb = 1000 PSI
F, = 1450 psi
No. 2 Fb = 875 psi
F, = 1300 psi
5" thick and larger
No.1 B&S Fb = 1350 psi
F, = 625 psi
No.1 P&T Fb = 1200 psi
F, = 1000 psi
Grades Width
No.1 and better
10
12
Stud
I14 and widel I 2,3, and 4 I 5and6
GLULAM BEAMS
24F-V4 Bending:
Axial:
24F-V8 Bending:
Axial:
F, = 675 psi
F,, I = 625 psi
F1 = 575 psi
F, I = 625 psi
F, = 675 psi
F, I = 625 psi
F, = 825 psi
F,, I = 625 psi
F, = 95 psi
E = I700000 psi
F, = 95 psi
E = 1600000 Dsi
F, = 85 psi
E = 1600000 psi
F, = 85 psi
E = 1600000 psi
Size Factor, C,
Fh I 1 "
Thickness F, Ft
2"& 3" I 4"
1.5 I 1.5 1.15 1.5
1.4
1 .o 1 .o 1 .I 1 .o 1 .o 1.1 1.2 1.1
1.05 1.2 1.3 1.2
1 .I 1.3 1.3 1.3
1 .I 1.4 1.4
0.9 I I .o 1 0.Q I 0.9
1.1 1.1 I 1 .I I 1.05
I .o I I .o 1.0 I 1 .o
Fb (l in T) = 2400 psi
Fb (l in C) = 1200 psi
E = 1 800000 psi
Fl=1150psi
Fb (T in T) = 2400 psi
Fb (l in C) = 2400 psi
E = I800000 psi
F1 = 1100 psi
F, I = 650 psi
F, = 165 psi
F, = 1650 psi E = 1600000 psi
F, I = 650 psi
F, 165 psi
F, = 1650 psi E = I600000 psi
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, Califwnia 92128
16959 Bemardo Center Drlva. Suite 201
Phone (619) 4858227. Fa (619) 4858201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page 9
DESIGN VALUES, continued
Soils Report By: Medall, Aragon, Higley Geotechnical. Inc.
Job NO.: 3630-SF
Allowable Bearing Pressure = 3000 psf Allowable Passive Pressure = 300 pcf
Minimum Footing Depth = 18 in. (continuous) Friction Coefficient = 0.4
Minimum Footing Width = 12 in. (continuous)
= 18 in (isolated)
= 24 in. (isolated)
Active Pressure = 35 pcf (cantilever wall)
= 55 pcf (restrained wall)
Expansion Potential = Low
STEEL
Pipe Columns: ASTM A53 Grade 8, Fy=35 ksi, Fp60 ksi
Tube Columns: ASTM A500 Grade B, Fy=46 ksi, F,=58 ksi
Other Shapes: ASTM A36, Fy=36 ksi
CONCRETE
Foundation, Slab, 8 Tilt-up Walls: fc = 3000 psi
CODE 8 PUBLICATIONS
UBC 1994 Edition
AISC, Ninth Edition
PC1 Design Handbook, Fourth Edition
Nelson Stud Welding Handbook for Non-Residential Construction
Simpson Strong-Tie Connectors
WOOD SHEARWALLS
denotes double-sided shearwall (plywood shall be staggered on each side)
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 92128
16959 Bernard0 Center Drive, Suite 201
Phone (619) 485-6277, Fax (619) 4855ZJI
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page 4
DESIGN VALUES, continued
I HORIZONTAL DIAPHRAGM
112" Thick Structural I rated plywood
A// edges supported (except at "e")
Nailed at: a) 2" O.C. EN 8 BN, FN at 12" O.C. (3x members req'd)
b) 2 1/2" O.C. EN 8 BN, FN at 12" O.C. (3x members req'd)
c) 4" O.C. EN 8 BN. FN at 12" O.C.
d) 6" O.C. EN 8 BN, FN at 12" O.C.
e) 6 O.C. EN 8 BN. FN at 12" O.C.
5/8" Thick Structural I rated plywood
All edges supported (excepf at "e")
Nailed at: a) 2" O.C. EN 8 BN, FN at 12" O.C. (3x members req'd)
b) 2 1/2" O.C. EN 8 BN, FN at 12" O.C. (3x members req'd)
d) 6" O.C. EN 8 BN, FN at 12" O.C.
e) 6 O.C. EN 8 BN. FN at 12" O.C.
C) 4" O.C. EN & BN, FN at 12" O.C.
CAPACITY OF HOLDDOWNS FOR
CONCRETE TILT-UP PANELS
v = 820 #/fl
v = 720 #/fl
v = 320 #/fl
v = 215 #/ft
v = 425 #In
v = 820 #/fl
v = 720 #/ft
v = 425 #/ft
v = 320 #/fl
v = 215 #/fl
Detail # SED-1
A
B
C
D
E
Cap. bar = (1.33)(0.442 in2)(24000 psi)
Cap. weld = (2)(4")(1/4'~(0.7)(0.3)(70,000 psi)
Cap. bar = (1.33)(0.601 in2)(24000 psi)
Cap. weld = (2)(4")(1/4")(0.7)(0.3)(70,000 psi)
Cap. bar = (1.33)(0.786 h2)(24000 psi)
Cap. weld = (2)(5.5")(1/4")(0.7)(0.3)(70,000 psi)
Cap. bar (1.33)(1.0 in2)(24000 psi)
Cap. weld = (2)(6'~(1/4")(0.7)(0.3)(70,000 psi)
Cap. bar = (1.33)(1.23 in2)(24000 psi)
Cap. weld = (2)(6.")(1/4")(0.7)(0.3)(70,000 psi)
Detail # 1.3E.D-
C
D
E
.I
Cap. bar = (2)(1.33)(0.786 in2)(24000 psi)
Cap. weld = (4)(5.5")(1/4")(0.7)(0.3)(70,000 psi)
Cap. bar = (2)(1.33)(1 .O in2)(24000 psi)
Cap. weld = (4)(6")(1/4")(0.7)(0.3)(70,000 psi)
Cap. bar = (2)(1.33)(1.23 in2)(24000 psi)
Cap. weld = (4)(6.5")(1/4")(0.7)(0.3)(70,000 psi)
= 14,108 Ibs = 29,400 Ibs
= 19,183 Ibs
= 29,400 Ibs
= 25,089 Ibs
= 40,425 Ibs
= 31,920 Ibs = 44,100 Ibs
= 39,261 Ibs
= 47,775 Ibs
= 50,178 Ibs = 80,850 Ibs
= 63,840 Ibs = 88,200 Ibs
= 78,522 Ibs
= 95,550 Ibs
FlROUZl
CONSULTING
ENGINEERS, INC.
16959 Bernard0 Center Drhre, SuLZUl
San Diego, California 92128
Phone (619) 4858227. FaX (619) 4858201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page
DESIGN VALUES, continued
CHORD CAPACITY
Capacity = Area x f. x 1.33
Assumed weld size = 114"
Capacity of 114" fillet weld = 3710 Ibs
f 46
2-#5
2-#6
2-#7
2"
L5x3xla
ClOx15.3
Capacity = (.44)(24000)(1.33) = 14044 LBS
Weld length required = (.44)(60000)(1.25) I ((2)(3710)) = 4.5 in
Capacity = 2(.30)(24000)(1.33) = 19152 LBS
Weld length required = (.30)(60000)(1.25) / ((2)(3710)) = 3.0 in
Capacity = 2(.44)(24000)(1.33) = 28090 LBS
Weld length required = (.44)(60000)(1.25) / ((2)(3710)) = 4.5 in
Capacity = 2(.60)(24000)(1.33) = 38304 LBS
Weld length required = (.60)(60000)(1.25) I ((2)(3710)) = 6.0 in
Capacity = 2(.78)(24000)(1.33) = 49795 LBS
Weld length required = (.78)(60000)(1.25) I ((2)(3710)) = 8.0 in
Capacity = (3.75)(24000)(1.33) = 119,700 LBS
Splice plate capacity = (4 in)(.875 in)(24000)(1.33) = 11 1,720 LBS
Splice weld capacity = (15 in)(5570 Ibs) = 83,550 LBS
Capacity = (4.49)(24000)(1.33) = 143,320 LBS
Splice plate capacity = (8 in)(.625 in)(24000)(1.33) = 159,600 LBS
Splice weld capacity = (27.5 in)(5570 Ibs) = 153,175 LBS
CAPACITY OF 8" CONCRETE WALL
Section 1911.1.1 Vu<+Vn vn = V" + v,
V"<+W"+VJ
Section 1911.10.3 Shear strength V, at any horizontal section for shear in plane of wall shall
not be taken greater than:
V, < 10 (f,J0.5 hd
< (10)(3000 psi)0.5(8n)(12")(0.8)
< 42065 Wfl
Section 1911.10.4 For design for horizontal shear forces in plane of wail, d = I,
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 92128
16959 Bernard0 Center Drive, Suite 201
Phone (619) 4858227, Fax (619) 4858201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov ‘98 Page 8
Section 1911.10.5
Section 1921.2.7
Section 1921.6.5.1
Section 1909.3
Section 1921 B.2.1
Section 1921.6.2.2
Section 1921.6.2.3
Unless a more detailed calculation is made, shear strength V, shall not
be taken greater than:
V, = 2 (fJ’.’ hd
= (2)(3000 psi)’~’(8’~(12”) = 10516 #/R
If Vu > +Va / 2, sheanvall reinforcing shall be per Section 1911.10.9
If V, > +Vu the value of V,=A,fyd/s2
For earthquake loading, the load factors shall be modified to:
U=1.4(D+L+E)
U = 0.9D + 1.4E
The shear strength reduction factor +, shall be per Section 1909.3
Shear strength reduction factor +, shall be 0.85 for shear and torsion
Minimum reinforcing ratio = 0.0025
A. (0.0025)(8”)(12”)
= 0.24 in2 (#5 at 14“ O.C. each way minimum)
Provide two curtains of reinforcement if the in-plane factored shear
exceeds 2A cv (PC) 0.5
For one layer of reinforcing:
Va,h, = (2)(8”/2 x 12”)(3000 psi)’.’(O.S) = 4207 Ib/ft
When Vu in the plane of the wall exceeds Acv(Pc) horizontal reinforcement
terminating at the edges of sheaf walls shall have a standard hook engaging
the edge reinforcement.
Vdh, = (8”/2 x 12”)(3000 psi)’.’ = 2629 IbMt
Special transverse reinforcement for shearwalls is not required if maximum
extreme fiber stress < 0.2 PC
F, = (9)(10516 #/fl)(1’)2/[(12”)(8”)2]
= 123 psi
0.2 f, = 0.2 (3000 psi)
= 600 psi > 123 psi OK, No boundary member required
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 92128
16959 Bernard0 Center Drive, Suite 201
Phone (619) 4856227. ax (619) 4856201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page 1-
ROOF FRAMING I Sub Purlins Above Office
Tributary area (ft') 16
w (Ib I ft) 70
Reaction (lb) 280
Moment (Ib-ft) 560
8'-0" Span
Allow Defl. I I )30(
Dead Load (ps9
Live Load (ps9
C,
CD
CF
I .25
Allow Defl. (in) 0.40 s req (in3) 3.60
A req (in') 3.54
I req (in") 9.49
Use 2x6 DFL #l at 24" O.C. (Use 4x4 DFL #l at Stram)
10°C)" SDan
Span (ft) Fl
AIIOW D;; I lxxx
Joist Spacing (in) Dead Load (ps9
fb (Psi) Live Load (ps9 f', (psi) 1.15
E (Psi) 1.7E+O6 CF 1.3
CD 1.25
Tributary area (fl') 20
w (Ib I fl) 70
Reaction (lb) 350
Moment (Ib-ft) 875
Allow Defl. (in) 0.50 s req (in3 5.62
A req (in') 4.42
I req (in") 18.53
Use 2x6 DFL #l at 24" O.C. (Use 4x6 DFL #l at Stram)
FlROUZl
CONSULTING
ENGINEERS, INC.
16959 Bernardo Center Drive. Suite 201
San Dkgo, California 52128
Phone (619) 4856227, Fax (619) 4856231
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov ‘98 Page
Purlins
P-I)
P-2)
P-3)
P-4)
P-5)
P-6)
ROOF FRAMING
Span (fl) Dead Load @sf)
Spacing (fl) Live Load (psf)
Trib Area (fl’) 412 w, (Ib I fl) 248
W, (Ib I fl) 128
Use: 32LH open web steel joists
Dead Load (psf)
Live Load (psf)
590 %(Ib/ft) 310
w, (Ib I fl) 160
Use: 32LH open web steel joists
1
Use: 18LH open web steel joists
Span (fl)
Spacing (fl)
Dead Load (psf)
Live Load (psf)
Trib Area (fl’) 285 wn (Ib 1 ft) 31 0
Use: 18LH open web steel joists
Span (ft)
Spacing (fl)
Dead Load (psf)
Live Load (psf)
Trib Area (fl’) 384 w, (Ib 1 fi) 248
WL, (Ib I ft) 128
Use: 28LH open web steel joists
Span (ft)
Spacing (ft)
Trib Area (ft’) 480 W, (lb 1 ft) 310
Dead Load (psf)
Live Load (psf)
w, (Ib I fl) 160
Use: 28LH open web steel joists
FlROUZl
CONSULTING
ENGINEERS, INC.
15959 Bernardo Center Drlve, Sub 201
San Diepo, Califomla 92128
Phone (619) 4858227, Fax (61s) u)58201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page &r
FRA MlNG
FlROUZl
CONSULTING
ENGINEERS, INC.
SIln Diego. Califomla 92128
IW C~IN DW, SUB MI
Plwm (619) 4858227, Fax (6lB) 4858201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov ’98 Page
~
Revised: Dec ‘98
ROOF FRAMING, continued
Girders
G-I)
G-2)
G-3)
G-4)
G-5)
G-5)
Trib width (fl)
Joist Spacing
Trib Area (ft’)
Span (fl)
30.25
1989
Use: 480 6N 10.4K Joist Girder
Trib Length (A)
Trib width (fl) 43.15
Joist Spacing
Trib Area (A2) 2215
I%]
Use: 52G 6N 12.OK Joist Girder
Trib width (fl)
Trib Length (fl)
43.15
Joist Spacing
Trib Area (ft’) 11 31.5
m
Use: 28G 3N 12.OK Joist Girder
Trib width (fl)
Trib Length (fl)
43.15
Joist Spacing
Trib Area (ft’) 1481.5
i]
Use: 32G 4N 12.OK Joist Girder
Trib width (ft)
Trib Length (fl)
43.15
Joist Spacing
Trib Area (fl’) 1925
l=iq
Use: 48G 5N 12.OK Joist Girder
Trib width (fl)
Trib Length (A)
Joist Spacing
Trib Area (f12) 1925
Dead Load (psf)
Live Load (psf)
# of Joist Soaces 6
Nodal Load (Ibs) 10328
Dead Load (psf)
Live Load (psf)
# of Joist Spaces 6
Nodal Load (Ibs) 11813
Dead Load @sf)
Live Load (psf)
# of Joist Spaces 3
Nodal Load (Ibs) 11 81 3
Dead Load (psf)
Live Load (psf)
# of Joist Spaces 4
Nodal Load (Ibs) 10631
Dead Load (psf)
Live Load (psf)
# of Joist Spaces 5
Nodal Load (Ibs) 10631
Dead Load @sf)
Live Load @sf)
# of Joist Spaces 8
Nodal Load (Ibs) 9450
Use: 52G 8N 12.OK Joist Girder
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego. Califcfnh 92128
18959 Bemardo Centef Driw. Sulte 201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page
~~
Revised: Dec '98
Phone (619) 485-5227. Fax (619) 4856201
ROOF FRAMING, continued
Beams
B-1) Along Line 3.5
Trib Width (fl) Span (fl)
Trib Area (fl') 228
8-2) Along Line 4.7
Trib Width (fl)
Trib Area (fl') 135
Span (fi)
8-3) Along Line 5.6
Span (fl) Trib Width (fl)
Trib Area (fl') 290
8-4) Along Line F.8
Trib Width (fl)
Trib Area (fl') 440
Span (fi)
8-5) Along Line 6
Span (fl) Trib Width (fl)
Trib Area (fl') 92
Dead Load @sf)
Live Load (psf)
% (Ib I fi)
wu (Ib I fl)
Dead Load (psf)
Live Load (psf)
'h (Ib I fl)
WLL (Ib I fi)
Dead Load (psf)
Live Load (psf)
h(Ib/fl)
w, (Ib I fl)
Dead Load (psf)
Live Load (psf)
w, (Ib I fl)
wu (Ib I fl)
Dead Load (psf)
Live Load (psf)
w,(IbIfl)
W, (Ib I fl)
248
128
F]
31 5
180
225
116
620
320
280
160
Firouzi Consulting Engineers, Inc Title : Ld 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201 Dsgnr: Date:
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Dercriptlon :
Scope :
Multi-Span Steel Beam I/
LGeneral Information t
Description Roof Beams: 6-1 thru 5
Fy - Yield Stress 36.00 lai Load Duration Factor 1 .00
Ail Spans Considered as Individual Beams
lsoan Information
End Fixity I Pin-Pin Pin.Pi0 Pin-Pin Pin-Pin Pin-Pi0
Loads I
Dead Load wn I 0.25 0.32 0.23 0.20 0.28
Live Load Point X1 DL 0.13 0.18 0.12 0.10 0.16
4.50
LL
Point #2 DL LL
@X n k
7.500
2.32
k
k
4.50
@X 14.500 fl
2.32
Results
Mmax @ Cntr k-R
fb : Actual
0.0
0.0 0.0
0.0 MW @ Right End k-fl
0.0 0.0
11.00 5.75
0.0 Max @ Len End k-fl
7.3
14.25 7.50 20.00 @X= n 38.2 13.9 68.2 69.3
0.0 0.0 0.0
psl 4,971.2 2,961.9 8,662.2 14,354.4 3,013.3 Fb : Aiiowable psi 23,760.0 23,760.0 23,760.0 23,760.0 23,780.0 hdiwOK Bending OK &odiopOK BcndinpOK hwOK
I
keactions & Deflections I Shear @ Lefl Shear @ Right k
k
5.36
5.36
3.71
3.71
6.82
6.82
10.12 2.53
10.12 Reactions ... 2.53
DL @ Len
LL @ Len
k
k
3.53 2.36 4.50
1 82 1.35
6.70 1.61
Total @ Len k 5.36 3.71 6.82
2.32 3.42
DL @ Right k
0.92
3.53 2.36
10.12 2.53
LL @ Right k 1.82 1.35
4.50 6.70
Total @ Right
1.61
5.36 k
2.32
Max. Deflection in
3.71 6.82
3.42 0.92
10.12 2.53
-0.301 -0.043 -0.688 -0.410 -0.030
5.75 @X= R 14.25 7.50 20.00 11.00
(C) 1983-97 ENERCALC c:!enercalc~otl06.ecw KW0602755, V5.0.2, 1 Jun-1997
FlROUZl Project: Lot 106 - Revised
CONSULTING Job #: 98244 By:
ENGINEERS, INC. Date: Nov '98 Page &
16959 Bemardo Center Drive, Sub MI
San Oio, California 92128
Phone (619) 485-6'227, Fax (619) 485-6201
FLOOR FRAMING
Floor Purlins
Span (fl) Spacing (fl) LL (psf) DL (psf) WTL Ob I fl) WLL (IbIfl) USE
943 520
943
1219
943
761
520
420
1918 1625
761 420 32LH
761 420 24LH
I Floor Girders
Trib Joist
Floor Beams
Trib
Span (fl) width (fl) Area (f12)
Trib
185
312
126
186
170
60
610
Joist Nodal
Load (klps)
22.6
22.6
22.6
46.5
24.7
24.7
20.0
18.3
34.1
36.6
18.9
15.2
~
32
WLL (PI9
0.520
0.960
0.420
0.960
0.400
0.680
1.600
wM (PI9
0.423
0.780
0.341
0.780
0.325
0.553
1.300
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227 Fax: 619) 485-6201
Title : Lot 106 Redesign Dognr: Date: Description :
Scope :
Job # 98244
~ ~~~.. .---, --- L Multi-Span Steel Beam 13
LGeneral Information 1
Description Floor Beams
Fy - Yield Stress 38.00 hi Load Duration Factor
Ail Spans Considered as individual Beams
1 .OO
I Span Information
Span Steel Shape 28.50 W16X40
26.00 wl4xss 24.00 15.50 12.00 20.00 30.50 15.50
W16XZ6 W18X35 WlOXll WL4X30 wl7X84 End Fixity Pin-Pin Pin-Pin Pin-pin Pn-Pin Pin-Pin Pin-Pm Pin.Pin Pin-F?n
WLOXZ6
Loads
Dead Load kJfl Live Load 0.52 0.96 0.42 0.96 0.40 0.68 1.60 0.27
Point#l DL 0.42 0.78 0.34 0.78 0.33 0.55 1.30 WR 0.60 k LL k 5.04 4.09
@X fl 1o.m
Mmax @ Cntr k-fl 95.7 147.0 54.8 77.6 13.0 61.6 337.2
14.25 13.00 12.00 26.1
Max @ Len End
9.40
k-fl 0.0 0.0 Max @ Right End
6.00 10.00 15.25 7.75
0.0
0.0
0.0 0.0 0.0
0.0 0.0 k-R
0.0 0.0
BmdlopOK BRldin.OK RmdinpOK RmdinpOK Beding OK BmdinpOK BmdiopOK Beading OK 23,760.0 23.760.0 23,760.0 23.760.0 23.760.0 23.760.0 23.760.0 23,760.0 Fb: Allowable
0.0 0.0 0.0 0.0
17,755.1 15,504.0 17,138.6 16.067.5 14,364.7 17,678.7 18,962.2 11,245.6 fb : Actual psi 0.0
@X= n
Shear a LeR k 22.62 9.13 16.43
13.44 Shear @ Right k
13.44
4.35 12.33 19.67 4.35
22.62 9.13
12.00 7.96 6.00 10.00 15.25 7.75 -0.271 13.00 4.683 14.25 -0.528 fl
-0.460 -0.651 -0.221 -0.217 6.74 -0.932 in
9.13 19.67 4.35 12.33 44.22
Max. Deflection
1.95 5.53 19.62 4.65
22.62
8.82
13.44 k
4.09 Total @ Right 10.14 2.40 6.80 24.40 2.09
6.03 LL @ Right k
10.85
12.33
5.04
9.13 16.43 4.35 44.22 6.74
7.41 12.48 DL @ Righl k
5.53 19.82 4.65 1 .% 13.44 22.62 Total @ Left k
7.36 2.09 10.14 4.09 6.03
5.04 9.07 2.40 6.80 24.40 LL @ Lefl k
7.41 12.48 DL @ Lefl k
12.33 44.22 6.74 Reactions ...
44.22 6.74
@X=
(c) 198597 ENERCALC c:bnercaicVotl06.ecw KW-0602755, V5.0.2. 1-Jun-1997
FlROUZl
CONSULTING
ENGINEERS, INC.
16959 Bernard0 Center Drive, Suite 201
San Diego. California 92128
Phone (619) 4856227. Fax (619) 485.6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page &
COLUMNS
Column Size
Height of Column
Load
Section Modulus
Area
Modulus of Elasticity
r
188.8
38.3
17.4
153
2.96
Maximum Deflection (IN) 0.96 e (IN) 2.88 Moment (IN-K) 440.64
fb (KSb 13.39
fa (W 10.63
0.96
2.88
543.744
14.20
10.85
Kllr 63.37 64.86
Fb 21.6 21.6
H 3 Ad L I
417
I 6 I
0.96
2.88
721.728
13.32
13.62
50.00
21.6
59.67 piZ"l
1.7 OK 1.54 < 1.7 OK
Tile : Lo1 106 Redesign
Description :
Scope :
16959 Bernard0 Center Drive #201 Dsgnr: Dale:
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Job # 98244
L Steel Column Base Plate 15
I 1 General Information
Description TSlOxlOx1/2 Columns
Axial Load 250.60 k
X-X Axis Moment 0.00 k-ft
Plate Height 18.000 in
Plate Width 18.000 in
Pier Height
Pier Width
72.000 in
72.000 in
fc
FY
3,000.0 psi
LDF
36.00 ksi
1.000
Plate Design
Analysis Type Min. Req'd Plate Thick 1.466 in
Tension Force per Bolt 0.000 k
Bearing Stress 773.46 psi
Max Plate Capacity for
3
Allow. Bearing 680.40k
Steel Section TS10x10x1/2
Section Depth
Section Width
10.000 in
10,000 in
Flange Thick 0.500 in
Web Thick 0.500 in
Anchor Bolt Data
Dist. from Plate Edge 1.500 in
Tension Capacity
Bolt Count per Side 2
2.750 k
Bolt Area 0.442 in2
Allow Concrete Bearing
PerACI 10.15
Per AlSC J9 2,100.0 psi
3,570.0 psi
Plate Thickness 1.5000 in
Max Allow Plate Fb 27,000.0 psi
Actual fb 25.761.9 Dsi
Plate Analysis for Specified Thickness
(c) 1983-97 ENERCALC C:\ENERCALC\LOT106,ECW KW-0602755, V5.0.2, I-Jun-1997
16959 Bernard0 Center Drive #201
San Diego, California 92128
Title : Lot 106 Redesign Jab # 98244 Drgnr: Deseriptlon : Date:
Phone: (619) 485-6227 scone !
Fax: (619) 485-6201 "-8".
Steel Column Base Plate
Description TS8x8x1/2 Columns
Axial Load 153.00 k
X-X Axis Moment 0.00 k-ft
Plate Height 16.000 in
Plate Width 16.000 in
Pier Height
Pier Width
72.000 in
72.000 in
fc 3,000.0 psi
LDF
36.00 ksi
1.000
FY
Plate Design
Analysis Type
Min. Req'd Plate Thick 1.237 in
Tension Force per Bolt 0.000 k
Bearing Stress 597.66 psi
Max Plate Capacity for
3
Ailow. Bearing 537.60k
Steel Section
Section Depth
Section Width
8.000 in
8.000 in
Flange Thick 0.500 in
Web Thick 0.500 in
TS8xEx112
Anchor Bolt Data
Dist. from Plate Edge 1.500 in
Tension Capacity
Bolt Count per Side 2
2.750 k
Bolt Area 0.442 in2
Ailow Concrete Bearing
PerACi 10.15
Per AlSC J9 2,100.0 psi
3,570.0 psi
Plate Thickness 1.5000 in
Max Allow Piate Fb 27.000.0 psi
Actual fb 18.360.0 osi
Piate Analysis for Specified Thickness
(C) 1983-97 ENERCALC C:\ENERCALC\LOTI06,ECW KW-0602755, V5.0.2. 1-Jun-1997
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 92128
16959 Bernard0 Center Drive. Suite 201
Phone (619) 485-6227, Fax (619) 485-8201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page
PANEL DESIGN
Wind Load: c,= 1.19
c, = 1.2
q,= 12.6
I = 1.0
Panel Dafa:
Panel Designation: Line A, Roof No Openings
Parapet Height = ~"~~ - Data Wall Heioht = 14.5 fl Wall Thickness = 8 in
Purlinspan= 48 n
Ledgerwidth = 3.5 in
Reveal Thickness = 0.75 in
Roof Dead Load = 15 psf Opening Width = 0 n Roof Live Load = 16 psf Opening Height = 0 n Wall Dead Load = 97 psf
1.5 n Distance to Rebar = 3.625 in
Leg Width = 1 ft
Calculation e = 7.5 in
POL = 360 plf
PLL = 384 plf
Panel Designation: Line A, Roof: 2"O" Leg
Data Wall Height = 14.5 ft
Parapet Height
Purlin Span
Ledger Width
Opening Width
Opening Height = 0
Leg Width = 2
..
= 1.5
= 48
= 3.5 - 18 -
Addt'l. Lateral = 0.0 psf
VDL = 0 Plf
VLL = 0 Plf
Wall Thickness = 8
Distance to Rebar 5.75 in
in
Reveal Thickness = 0.75 in
Roof Dead Load = 15 psf
Wall Dead Load =
Roof Live Load = 16 psf
97 psf
Calculation e = 7.5 in Addt'l. Lateral = 130.5 psf
POL = 360 plf VDL 4665 plf
PLL = 384 plf VLL= 1728 plf
Panel Designation: Line A, Roof 4-0" Leg
Data Wall Height = 14.5 ft Wall Thickness = 8 in - Parapet Height = 1 .f
Purlin Span = 48
Ledger Width = 3.:
Opening Width = 9
Opening Height = 9
Leg Width = 4
- - - - -
I,
- in ~ ~~~~ ~
Distance to Rebar = 5.75 in
ift Reveal Thickness = 0.75 in
~~~ - - i in Roof Dead Load = 15 psf
16 psf - - n Roof Live Load = n - Wall Dead Load = 97 psf
H
Calculation e = 7.5 in Addt'l. Lateral = 32.6 psf
PDL= 360 plf V~L= 1166 plf
PLL = 384 plf VLL= 432 plf
FlROUZl Project: Lot 106 Redesign
CONSULTING
ENGINEERS, INC.
Job #: 98244 By:
Date: Nov '98 Page &
16959 Bernard0 Center Drive, Suite 201
San Diego, California 92128
Phone (61 9) 485-6227, Fax (61 9) 465-6201
- PANEL DESIGN, continued
Panel Designation: Line A, Floor: 4'-0 Leg
Data
Calculation
Wall Height
Parapet Height
Floor Framing Span
Roof Framing Span
Ledger Width
Opening Width
Opening Height
Leg Width
Wall Thickness = 8
Distance to Rebar = 5.75 in
in
Reveal Thickness = 0.75 in
Roof Dead Load = 15 psf
Roof Live Load =
Floor Dead Load = 65 psf
16 psf
Floor Live Load = 80 psf
Wall Dead Load = 97 psf
e = 7.5 in Addt'l. Lateral = 72.5 psf
PLL = 1344 plf VLL= 3360 plf
POL = 1140 plf VDL = 4300 plf
Panel Designation: Line 1 & 6, Roof: 2-0 Leg
Data
Calculation
Wall Height = 14 ft
Roof Framing Span = 10 ft
Parapet Height = 1.5 ft
Floor Framing Span = 0 n
Ledgerwidth = 3.5 in
Opening Width 18 fl
Opening Height = 9 fl
Leg Width = 2 n
e = 7.5 in Addt'l. Lateral = 130.5 psf
PDL = 75 plf VDL= 3165 plf PLL = 100 plf VLL= 450 plf
Calculation
Wall Thickness = 8
Distance to Rebar = 5.75 in
in
Reveal Thickness = 0.75 in
Roof Dead Load = 15 psf
Roof Live Load =
Floor Dead Load = 20 psf
0 PSf
Floor Live Load = 0 PSf
Wall Dead Load = 97 psf
Panel Designation: Line 1 & 6. Floor: 4'-0" Leg
Data Wall Height = 16 ff
Parapet Height = 0 n
Roof Framing Span = 10 ft
Floor Framing Span = 6.5 ft
Ledger Width = 2.6 in
Opening Width = 20 fl Opening Height = 10 fl
Leg Width = 4 n
Wall Thickness = 8
Distance Io Rebar 5.75 in
in
Reveal Thickness = 0.75 in
Roof Dead Load = 15 psf Roof Live Load = 20 osf ~~
Floor Dead Load = 65 psf
Wall Dead Load = Floor Live Load = 80 psf
97 psf
r-.
e = 6.6 in Addt'l. Lateral = 72.5 psf
POL 286 plf VDL= 2166 plf
PLL= 360 plf VLL = 900 plf
FlROUZl
CONSULTING
ENGINEERS, INC.
16959 Bernard0 Center Drive, Suite 201
San Diego. California 92128
Phone (619) 485-6227. Fax (619) 485-6201
Project: Lot 106 Redesign
Job #: 98244
Date: Nov '98 Page Lf
PANEL DESIGN, continued
I Panel Designation: Lines 1 & 6, Floor: No Openings
I
Data
Calculatlon
Wall Height
Roof Framing Span
Parapet Height
Floor Framing Span
Ledger Width
Opening Width
Opening Height
Leg Width
Wall Thickness = a in
Distance to Rebar
Reveal Thickness
Roof Dead Load
Roof Live Load = 20 psf
Floor Dead Load
Floor Live Load
Wall Dead Load
~ ~ ~~ ~~
.. r-.
. .- - 3.625 in
,- - 0.75 in - 15 osf
.. .
-
- - 65 psf - 80 psf - 97 psf
- -
e = 7.5 in Addt'l. Lateral =
POL' 286 plf
PLL= 360 plf VLL 0 Plf
0.0 psf
VDL = 0 Plf
Panel Designation: Line G. Roof: No Openings
Data Wall Heioht = 13 A fl Wall Thickness 8
Distance to Rebar = 3.625 in
in
Reveal Thickness = 0.75 in
Roof Dead Load = 15 osf
Roof Live Load = 16 psf Floor Dead Load = 0 Psf
r ~.
Floor Live Load = 0 PSf Wall Dead Load = 97 psf
Calculation e = 7.5 in Addt'l. Lateral = 0.0 psf
PDL = 439 plf VDL = 0 Plf
PLL = 468 plf VLL = 0 Plf
Panel Designation: Line G, Roof: 2"O" Leg
Data Wall Height = 13.8 fl Wall Thickness = a
Parapet Height = 2.2 ft Distance to Rebar 5.75 in
in
Roof Framing Span = 58.5 ft
Floor Framing Span = 0
Reveal Thickness = 0.75 in
ft
Ledger Width = 3.5 in
Roof Dead Load = 15 psf
Roof Live Load =
Opening Width = 18 ft
16 psf
Floor Dead Load =
Opening Height = 9 ft
0
Floor Live Load = PSf
Leg Width = 2
0
ft Wall Dead Load = 97 psf PSf
Calculation e = 7.5 in Addt'l. Lateral = 130.5 psf
PDL = 439 plf v,, = 5019 plf
PLL = 468 plf VLL = 2106 plf
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 92128
16959 Bernard0 Center Drive, Suite 201
Phone (619) 485-6227, Fax (619) 4856201
Project: Lot 106 Redesign
Job #: 98244 Bv:
Date: Nov '98 Page 20
PANEL DESIGN, continued
I Panel Designation: Line G, Roof: 4-0" Leg
Data
Calculation
Wall Height 13.8 fl
Parapet Height = 2.2 fl
Roof Framing Span = 58.5 fl
Floor Framing Span = 0 fl
Ledger Width = 3.5 in
Opening Width = 9 fl
Opening Height = 9 fl
Leg Width = 4 fl
Wall Thickness = a in
Distance to Rebar
Reveal Thickness
Roof Dead Load
Floor Dead Load
Roof Live Load
Wall Dead Load
Floor Live Load
~.~~. ~ . .- - 5.75 in
, = 0.75 in - 15 psf 16 psf
0 PSf
Psf 97 psf
.. .
-
- - - - 0 - -
e = 7.5 in Addt'l. Lateral = 32.6 psf
PDL 439 plf VDL 1255 plf
PLL= 468 plf VLL 527 plf
Panel Designation: Line G. Floor: 4'-0 Leg (1)
Data Wall Height
Parapet Height
Roof Framing Span
Floor Framing Span
Ledger Width
Opening Width
Opening Height
Leg Width
= 16 fl - - n fl
= 20 fl - In ft - - - 4 fl
Wall Thickness = 8
Distance to Rebar = 3.625 in
in
Reveal Thickness = 0.75 in
Roof Dead Load = 15 psf Roof Live Load = 16 psf Floor Dead Load = 65 psf Floor Live Load = 80 psf Wall Dead Load = 97 psf
Calculation e= 7 in Addt'l. Lateral 72.5 psf
PDL= 1089 plf VDL 4172 plf
PLL' 1268 plf VLL= 3170 plf
Panel Designation: Line G, Floor: 4-0" Leg (2)
Data
Calculation
Wall Height 16 fl
Parapet Height = 0 fl
Roof Framing Span = 58.5 ft
Floor Framing Span = 58.5 fl
Ledger Width = 3
Opening Width = 20 ft
in
Opening Height = 10 fl
Leg Width = 4 fl
Wall Thickness
Distance to Rebar
Reveal Thickness
Roof Dead Load
Floor Dead Load
Roof Live Load
Wall Dead Load
Floor Live Load
- - 17 in .-
,- - 9.75 in
...
= 0~75 in - - - 15 psf .. .
= 87.5 psf
- 16 psf
- - 100 psf
-
= 145 psf
e= 9 in Addt'l. Lateral = 108.8 psf
POL= 2998 plf VDL= 9670 plf
PLL= 3393 plf VLL= 8483 plf
FlROUZl
CONSULTING
ENGINEERS, INC.
16959 Bernard0 Center Drive, Suite 201
San Diego, California 92128
Phone (619) 4856227, Fax (619) 485-6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page
PANEL DESIGN, continued
Panel Designation: Line 8.2, Floor: 2-0 Leg
Data
Calculation
Wall Height = 16 fl
Parapet Height = 0 fl
Floor Framing Span = 20 ft
Roof Framing Span = 20 fl
Ledger Width = 3
Opening Width = 8
in
fl
Opening Height = 12.5 ft
Leg Width = 2 n
Wall Thickness
Distance to Rebar
Reveal Thickness
Roof Dead Load
Roof Live Load
Floor Dead Load
Floor Live Load
Wall Dead Load
- - 8 in
= 5.75 in
= 0.75 in - 15 psf - 16 psf - 65 psf - 80 psf - 97 PSf
- - - - -
e= 7 in Addt'l. Lateral = 58.0 psf PDL = 800 plf VDL 2277 plf PLL = 960 plf VLL= 1920 plf
Panel Designation: Line 8.2, Floor: 8"0 Leg
Data
Calculation
Wall Height
Parapet Height
Floor Framing Span
Roof Framing Span
Ledger Width
Opening Width
Opening Height
Leg Width
- - 16 ft - 0 ft
= 20 ft
- 3 in - 8 fl
= 12.5 fl - 8 n
-
= 20 n - -
-
Wall Thickness = 8
Distance to Rebar = 5.75
in
Reveal Thickness = 0.75
Roof Dead Load = 15
Roof Live Load = 16
Floor Dead Load = 65
Floor Live Load = 80
Wall Dead Load = 97
in
in -
e= 7 in Addt'l. Lateral = 14.5 psf
POL 800 plf VDL = 569 plf
PLL= 960 plf VLL= 480 plf
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Tltle : Lot 106 Redesign Drgnr: Date: Description :
Job # 08244
SCODe ! Fax: (619) 485-6201
Tilt-Up Wall Panel Design 72 L . "
LGeneral Information 1
Description Line A, Roof: No Openings
Clear Height
Thickness
Parapet Height
Bar Size
Bar Spacing Bar Depth
Max Defl. Ratio
Concrete Weight
14.500 ft 1.500 ft
8.000 in Phi
PC 3,000.0 psi Seismic Zone 4
FY 60,000.0 psi 0.900 Min Vert Steel % 0.0020
Min Horiz Steel %
5
0.0012
Width 12.000 in Base Fixity
14.000 in 3.625 in Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000 Parapet Seismic Factor 0.3000
150.0
145.00 pcf Using: UBC Sec. 1914.0 method ... Exact. Non-Iterated
LL 8 ST Together
0%
. 1 Loads i
Lateral Loads
~~
Wind Load 18.000 psf
Point Load Ibs ... height ... load type Seismic
Lateral Load #/It ... distance to top ft ... distance to bot R
n
Vertical Loads Uniform DL
Uniform LL ... eccentricity
~~ ~~
360.00 #lft
384.00 #/ft 7.500 in
Concentric DL
Concentric LL
Seismic"1" Maanifier 1.000
Wft
Wfl
... load type Seismic Wind "I" Magnker 1.000 ~~
[ Wall Analysis 1
Basic Defl wlo P-Delta
For Factored Load Stresses For Service Load Deflections Seismic Wind Seismic Wind 0.029 0.022 in 0.024 0 018 in
Basic M wlo P-Delta 14,467.5 10,666.6 in# Moment Excess of Mcr 0.0 0.0 0.0 in# 0.0 in#
8,658.7 in#
Max. P-Delta Deflection
Max P-Delta Moment 19,723.6 14,770.8 in# 13,737.4 10,423.9 in#
Maximum Allow Vertical Bar Spacing
Maximum Allow Horizontal Bar Spacing 18.000 in
18.000 in Parapet Bar Spacing Req'd : SEISMIC 18,000 in
Parapet Bar Spacing Req'd : WIND 18.000 in
Wall Design OK
14.50ft clear height, 1.50n parapet, 8.00in thick with #5 bars at 14.00in on center, d= 3.63in, fc = 3,000.0ps
Using: UBC Sec. 1914.0 method ... Exact, Non-iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
. . . . . . .
11,921.1
2.367 2.408 in 0.024 0.018 in
Maximum Iterated Moment : Mu
Moment Capacity
35,480.64 in#
58,944.25 in#
Maximum iterated Deflection
Deflection Limit
0.038 in
1.160 in
Mn * Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @ Top of Wall
Max Iterated Service Load Deflection
Actual Deflection Ratio
Seismic 53,669.54 in-#
19,723.64 in-#
8,360.10 in-#
7,186 : 1
0.02 in
I Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 * Rho Bal 0.0061
0,0128
52,542.60 in-#
14,770.81 in-#
6,816.82 in-#
Wind
9,907 : 1
0.02 in
0.0081
0.0128
Allowable Axial Stress = 0.4 fm
Actual Axial Stress : (Pw + Po ) IAg 120.00 psi
16.56 psi 16.56 psi
120.00 psi J
(c) 198597 ENERCALC c:\enercalcVotl06.ecw kW0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201 Dsgnr: Date:
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Description :
Scope :
Tilt-Up Wall Panel Design
1 Analysis Data
E 3,122,018.6 psi n = Es I Ec 9.29
Fr = 273.86 psi Ht I Thk Ratio 21.75
Sgross 128.000 in3
Mcr = S Fr
Rho: Bar Reinf Pct 35,054.2 in# 0.0214
Values for Mn Calculation...
As:eff= [Pu:tot + AsFyYFy 0.303 in Wind
a : (AsFy + Pu)1(.85 PC b) 0.594 in
0.295 in
0.578 in c=a1.85 0.699 in
512.000 in4
0.680 in
lcracked 512.00 in4 25.45 in4 25.02 in4 I-eff (ACI methods only) 0.00 in4 Phi: Capacity Reduction 0.00 in4 0.900
Mn = As:eff Fy (d - an) 59.632.82 in# 0.900
58,380.66 in#
Seismic
tgross
[Additional Values 1 Loads used for analysis
Wall Weight 96.667 psf
Wall Wt *Wall Seismic Factor 29.000 psf
Seismic
Applied Axial Load 1,041.60
Wind
Wall Wt * Parapet Seismic Factor 29,000 psf 867.60 #/ft
Lateral Wall Weight 1,184.17 Service Applied Axial Load 744.00 #In Total Lateral Loads 2,225.77 1,755.72#1ft 888.12 #/ft
Service Wt @ Max Mom 845.83 #In
Total Service Axial Loads 1,589.83 #In
Factored Loads
ACI 9-1 a 9-2 DL
ACi 9-1 8 9-2 LL
1.400
1.700
ACI 9-2 Group Factor
ACI 9-3 Dead Load Factor
0.750 UBC 1921.2.7"1.4" Factor 1.400
0.900 UBC 1921.2.7"O.Q'Factor 0~900 ACI 9-1 a 9-2 ST .... seismic = ST* : 1.100
1.700 ACI 9-3 Shoe Term Factor 1.300
(c) 1983-97 ENERCALC c:knercalcUotl06.ecw KW4602755, V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Title : Lot io6 Redesign Dsgnr: Date: Description :
Job # 98244
Smnn. Fax: (619) 485-6201 "_r_.
L Tilt-Up Wall Panel Design 24
[General Information I
Description Line A, Roof: 2-0 Leg
Clear Height 14.500 n rC 3,000.0 psi Seismic Zone
Parapet Height 4
Thickness 8.000 in Phi 0.900
0.0020
Min Horiz Steel % Bar Size 5 Width Base Fixity 0% 0.0012
Bar Spacing 12.000 in
11.000 in
Bar Depth 5.750 in Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000
Max Defl. Ratio Parapet Seismic Factor 0.3000 150.0 Concrete Weight 145.00 PCf LL 8 ST Together
Usina: UBC Sec. 1914.0 method ... Exact. Non-Iterated
1.500 n FY 60,000.0 psi Min Vert Steel %
LLoads I
Lateral Loads Vertical Loads Wind Load 18.000 psf Uniform DL 360.00 #/fl
Uniform LL 384.00 Wn Point Load ... height ... load type Seismic Concentric DL 4,665.00 wt
Concentric LL 1,728.00 #In
Ibs ... eccentricity 7.500 in n
Lateral Load 130.50 ... distance to top 9.000 n ... distance to bot ... load type Seismic n
Wind "111 Magnifier
Seismic "111 Magnifier 1.000
1.000 I Wall Analysis t
For Factored Load Stresses For Service Load Deflections Seismic
Basic Defl w/o P-Delta 0.107
Basic M w/o P-Delta
0.022 in
Moment Excess of Mcr
Seismic Wind
56,240.7 10,666.6 in# 41,471.6 0,658.7 in#
36.302.0 0.0 in# 15.618.2 0.0 in#
0.080 0.018 in
Max. P-Delta Deflection 1.364 1.433 in
Max P-Delta Moment
.~ ~~~ ..~ ..
0.251
71,356.3 23,151.2 in# 50,672.4 17,723.2 in#
Maximum Allow Vertical Bar Spacing 18.000 in Parapet Bar Spacing Req'd : SEISMIC 18,000 in Maximum Allow Horizontal Bar Spacing 18,000 in Parapet Bar Spacing Req'd : WIND 18.000 in
0.018 in
Summary
14.50fl clear height, 1.50fl parapet, 6.00in thick with #5 bars at 11.00in on center, d= 5.75in, fc = 3,000.0ps
Using: UBC Sec. 1914.0 method ... Exact. Non-Iterated
1 Wall Design OK
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Maximum Iterated Moment : Mu
Moment Capacity
35,480.64 in#
56,944.25 in#
Maximum Iterated Deflection
Deflection Limit
0.038 in
1.160 in
Mn *Phi : Moment Capacity
Applied: Mu @ Mid-Span Applied: Mu @Top of Wall
130.677.66 in-# Seismfc
71,356.25 in-# 8,360.10 in-#
~~
Max Iterated Service Load Deflection 0.25 in
Actual Deflection Ratio 692 : 1
Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 Rho Bal 0.0049
0.0128
124.397.00 in-# Wind
23,151.15 in-#
6,816.82 in-#
.. . ..
9,907 : 1
0.02 in
0.0049
0.0128
Actual Axial Stress : (Pw + Po ) /Ag
Allowable Axial Stress = 0.4 fm 120.00 psi 83.15 psi
120.00 psi
83.15 psi
-
(c) 198597 ENERCALC c:\enercaicVotl06.ecw KW-0602755, V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
I6959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Fax: (619) 485-6201
Title : Lot 106 Redesign
Dsgnr: Date: Description :
Scope :
Job # 98244
.. L Tilt-Up Wall Panel Design I Analysis Data
n=Es/Ec
Fr =
Ht / Thk Ratio
Values for Mn Calculation... As:eff= [Pu:tot + AsFy]/Fy
a : (AsFy + Pu)/(.85 PC b) c = a I.85
lgross 512.000 in4
lcracked 107.50 in4
I-eff (ACI methods only) 0.00 in4
Phi: Capacity Reduction Mn = As:eff Fy (d - aQ) 145,197.43 in-#
I
E 3,122,018.6 psi Sgross
9.29 Mcr = S * Fr
128.000 in3
35,054.2 in#
273.86 psi Rho: Bar Reinf Pct 0.0214
21.75
Seismic Wind
0.524 in 0.486 in
1.028 in 0.953 in
1,210 in
512.00 in4
1.121 in
102.34 in4
0.00 in4
138,218.09 in# 0.900 0.900
LAdditional Values I Loads used for analysis
Wall Weight 96.667 psf
Wall Wt 'Wall Seismic Factor 29,000 psf Applied Axial Load 9,991.80 7,969.05 #/ft
Wall Wt * Parapet Seismic Factor 29,000 psf Lateral Wall Weight 1,184.17
Service Applied Axial Load 888.12 #/ft
Service Wt @ Max Mom 7,137.00 #/ft Total Lateral Loads 11.175.96 8,857.17#/ft
845.83 #/ft
Total Service Axial Loads 7,982.83 #/R
Factored Loads Seismic Wind
[ ACI Factors (per ACi, applied internally to entered loads)
ACI 9-1 a 9-2 DL
ACI 9-1 a 9-2 LL 1.700
ACI 9-1 a 9-2 ST
I 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4"Factor 1.400
ACi 9-3 Dead Load Factor 0.900 UBC 1921.2.7"O.Q Factor 0,900
1.700 .... seismic ST *: 1.100
ACI 9-3 Short Term Factor 1.300
(C) 1983-97 ENERCALC c:knercalc\oiEG.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Title : Lot 106 Redesign Dsgnr: Date: Description :
Job # 98244
SC""C ! Fax: (619) 485-6201 "-8".
Tilt-Up Wall Panel Design 26 h L - "
\General Information 1
Description Line A, Roof: 4'-0 Leg
Clear Height
Thickness
Parapet Height
Bar Size
Bar Spacing
Max Defl. Ratio
Bar Depth
Concrete Weight
14.500 n
1.500 n
8.000 in
14.000 in 3.625 in
150.0
5
145.00 DCf
PC 3,000.0 psi
FY 60,000.0 psi Min Vert Steel 56 0.0020
Seismic Zone 4
Width
Phi 0.900 Min Horiz Steel Oh 0.0012
Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000
12.000 in Base Fixity 0%
Parapet Seismic Factor 0.3000
Usina: UBC Sec. 1914.0 method ... Exact. Non-Iterated
LL 8 ST Together
I Loads I
Lateral Loads Vertical Loads Wind Load 18.000 psf Uniform DL
Uniform LL Point Load Ibs ... eccentricity
360.00 #/n
384.00 #In
1,168.00 #In
... height n ... load type Seismic Concentric DL
Concentric LL
7.500 in
Lateral Load 432.00 #/a
... distance to top 9.000 n ... distance to bot ... load type Seismic
32.60 #In
n Seismic "111 Magnifier 1.000
Wind 'Io( Magnifier 1.000 I Wall Analysis I
For Factored Load Stresses For Service Load Deflections
Basic Defl w/o P-Delta
Basic M wlo P-Delta
- Seismic Wind Seismic Wind 0.049 0.022 in
24.729.6 10.666.6 in# 19.062.9 8 658 7 in4
0.038 0,018 in
Moment Excess of Mcr 426.4 0.0 in# Max. P-Delta Deflection 2.413 0.0 0.0 in#
Max P-Delta Moment 2.485 in
35,480.6 19,256.9 in#
0.038 22,760.8 0.018 in
12,230.1 in#
Maximum Allow Horizontal Bar Spacing 18.000 in
Maximum Allow Vertical Bar Spacing 18.000 in Parapet Bar Spacing Req'd : SEISMIC 18,000 in
Parapet Bar Spacing Req'd :WIND 18.000 in
Wall Design OK
14.50ft clear height, 1 Soft parapet, 8.00in thick with #5 bars at 14.00in on center, d= 3.63in, fc = 3,000.0ps
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
.~ ~~~ ... ..
Maximum Iterated Moment : Mu
Moment Capacity 35,480.64 in#
58,944.25 in#
Maximum Iterated Deflection 0.038 in
Deflection Limit 1.160 in
Mn ' Phi : Moment Capacity
Applied: Mu @I Mid-Span Applied: Mu @Top of Wall
Max iterated Service Load Deflection
Actual Deflection Ratio
Seismic 58,944.25 in-#
35,480.64 in-#
8,360.10 in-#
4,565 : 1
0.04 in I Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 Rho Bal 0.0061
0.0128
56,764.40 in-#
19,256.90 in#
6,816.82 in-#
9,907 : 1
0.02 in
Wind
0.0061
0.0128
Actual Axial Stress : (Pw + Po ) / Ag 33.21 psi
Allowable Axial Stress = 0.4 * fm 120.00 psi 33.21 psi
120.00 psi
" J
(c) 1983-97 ENERCALC __ c:\enercalcUott06.ecw KW-0602755, V5.0.2, 1-Jun.1997
Firouzi Consulting Engineers, Inc
San Dieao. California 92128
16959 Bernard0 Center Drive #201
Title : Lot 106 Redesign Job # 98244 Drgnr: Description : Date:
Phone: {SiS) 485-6227
Fax: (619) 485-6201 Scope :
Tilt-Up Wall Panel Design
LAnalysis Data
E n=Es/Ec
Fr = 273.86 psi Rho: Bar Reinf Pct 0.0214
Ht / Thk Ratio
1
3,122,018.6 psi Sgross 9.29 Mcr = S * Fr 128.000 in3
35,054.2 in#
21.75
Values for Mn Calculation ... As:eff= [Pu:tot + AsFy]/Fy Seismic
0.340 in
0.687 in 0.785 in
Wind
0.325 in
0.636 in
0 749 in
...
lgross 512.000 in4
lcracked 27.42 in4
I-eff (ACi methods only) 0.00 in4
Phi: Capacity Reduction 0.900
Mn = As:eff Fy (d -an)
. . . . - . . . 512.00 in4
26.62 in4 0.00 in4
0.900
65,493.61 in-# 63,071.56 in#
Wall Weight 96.667 psf
Wall Wt * Wall Seismic Factor 29,000 psf Applied Axial Load 3,278.80 2,642.70 #/ft Wall Wt * Parapet Seismic Factor 29.000 psf Service Applied Axial Load Lateral Wall Weight 1,184.17 888.12 #/ft
Service Wt @ Max Mom
Total Selvlce Axial Loads 3.187.83 #/ft [ ACI Factors (per ACI, applied internally to entered loads)
Factored Loads Seismic Wind
2,342.00 #In Total Lateral Loads 4,462.97 3,530.82#/ft 845.83 #In
ACI 9-1 8 9-2 DL 1.400
ACI 9-1 8 9-2 LL
ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4" Factor 1.400
1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7"O.Q Factor 0.900
ACI 9-1 8 9-2 ST 1.700 ACi 9-3 Short Term Factor 1.300
I
.... seismic= ST': 1.100
(C) 1983-97 ENERCALC c:\enercalcUotlOS.ecw KW-0602755, V5.0.2, 1Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Title : Lot 106 Redesign Dsgnr: Date: Description :
scam !
Job # 98244
Fax: (619) 485-6201 . .. ," -
L Tilt-Up Wall Panel Design 28
LGeneral Information 1
Description Line A, Floor: 4'-0" Leg
Clear Height Parapet Height
16.000 R
Thickness
0.000 n 8.000 in
Bar Size 5 Bar Spacing Bar Depth 11.000 in 5.750 in
Max Defl. Ratio Concrete Weight 150.0
145.00 DCf
PC 3,000.0 psi Seismic Zone
FY
4
Phi
60,000.0 psi
0.900
Min Vert Steel % 0.0020
Min Horiz Steel %
Width 12.000 in 0.0012 Base Fixity
Parapet Weight Counteracts Midd Wail Seismio Factor 0.3000 Parapet Seismic Factor 0.3000
Using: UBC Sec. 1914.0 method ... Exact. Non-Iterated
LL 8 ST Together
0%
1 Loads 1
Lateral Loads Vertical Loads Wind Load 18.000 psf Uniform DL 1,140.00 #In
Point Load ... height ... load type Seismic Concentric DL 4,300.00 wn
Concentric LL 3,360.00 #/ft
Uniform LL
Ibs ... eccentricity 1,344.00 #/a
7.000 in a
Lateral Load ... distance to top ... distance to bot ... load type Seismic
72.50 #/ft 10.0oo n n
Wind "1" Magnifier
Seismic "I" Magnifier 1.000
1.000 1 Wall Analysis t
For Factored Load Stresses For Service Load Deflections Seismic Basic Defl wlo P-Deita
Basic M w/o P-Delta
Moment Excess of Mcr
- Wind Seismic Wind ~~
0.118 0.051 in 0.098 0.042 in 49,318.1 21,941.0 in# 39,840.0
39.687.5 6.714.7 in# 18.759.9 18.339.0 in#
0.0 in# Max. P-Deita Deflection 1.666 1.751 in Max P-Deita Moment 74,741.7 41.768.9 in# 53,814.2 0.325
30,483.5 in#
0.042 in
Maximum Allow Vertical Bar Spacing 18.000 in
Maximum Ailow Horizontal Bar Spacing 18,000 in Parapet Bar Spacing Req'd : SEISMIC 18,000 in
Parapet Bar Spacing Req'd : WIND 18,000 in
Wall Design OK
16.00fl clear height, O.OOA parapet, 8.00in thick with #5 bars at 11 .OOin on center, d= 5.75in, fc = 3,OOO.Ops
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
~
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Maximum Iterated Moment : Mu 35,480.64 in#
Moment Capacity 58,944.25 in#
Maximum Iterated Deflection
Deflection Limit
0.038 in
1.160 in
Mn * Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @Top of Wall
141,417.14 in-# Seismic
134,249.96 in-#
74,741.73 in-# 41,768.94 in-#
24,343.19 in-# 20,374.19 in-#
Wind
Max Iterated Service Load Deflection 0.33 in Actual Deflection Ratio 590 : 1
Actual Reinforcing Percentage Allowable Max. Reinf. Percent = 0.5 *Rho Bal 0.0049
0.0128
4,568 : 1
0.04 in
0.0049
0.0128
Actual Axial Stress : (Pw + Po ) I Ag
Allowable Axial Stress = 0.4 * fm 113.72 psi 113.72 psi
120.00 psi 120.00 psi
(C) 1963-97 ENERCALC c:!enercalcUotlO6.ecw KW-0602755, V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Title: Lot 106 Redesign Dsgnr: Date: Description :
Job # 98244
RP""P.
Fax: (619) 485-6201 "-r_.
Tilt-Up Wall Panel Design 24 h
E 3,122,018.6 psi n = Es I Ec 9.29
Fr = 273.86 psi Ht / Thk Ratio 24.00
Values for Mn Calculation...
As:eff= IPu:tot + AsFvVFv
Seismic
0.593 in
Sgross 128.000 in3 Mcr = S Fr
Rho: Bar Reinf Pct
35,054.2 in#
0.0214
Wind
0.547 in
a : (ASFY + PU)I(.~~ PC bj 1.163 in 1.072 in c=a1.85 1.368 in lgross 1.262 in
512.000 in4 512.00 in4 lcracked 116.00 in4
I-eff (ACI methods only)
110.37 in4
0.00 in4 Phi: Capacity Reduction 0.00 in4
Mn = As:eff Fy (d - an) 157,130.15 in-# 0.900
149,166.62 in#
0.900
[Additional Values 1
Loads used for analysis
Wall Weight
Wall Wt *Wall Seismic Factor
96.667 psf
29.000 psf Applied Axial Load 14,201.59 11,709.60 #Ifl Wall Wt Parapet Seismic Factor 29,000 psf
Service Applied Axial Load 10,144.00 #/fl Lateral Wall Weight 1,082.67 812.00 #Ifl
Service Wt @ Max Mom 773.33 #/fl Total Lateral Loads 15,284.26 12,521.60#Ifl
Total Service Axial Loads 10,917.33 #/fl
LAC1 Factors (per ACI. applied internally to entered loads)
Factored Loads Seismic Wind
1 ACI 9-1 a 9-2 DL 1.400 ACI 9-2 Group Factor
ACI 9-1 a 9-2 LL 1.700
ACI 9-1 a 9-2 ST
0.750 UBC 1921.2.7"1.4" Factor 1.400
ACI 9-3 Dead Load Factor
1.700
0.900 UBC 1921.2.7 "0.9 Factor 0,900
.... seismic = ST' : 1.100 ACI 9-3 Short Term Factor 1.300
(c) 1983-97 ENERCALC c:\enercalc~otl06.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201 Dsgnr: Date:
San Diego, California 92128
Phone: (619) 485-6227 Fax: (619) 485-6201
Description :
Scope :
L Tilt-Up Wall Panel Design 30
1 I General Information
Description Line 1 & 6, Roof: 2-0 Leg
Clear Height
Thickness
Parapet Height
Bar Size
Bar Spacing Bar Depth
Max Den. Ratio Concrete Weight
14.500 ft
1.500 ft
PC
FY
3,000.0 psi Seismic Zone 4
60,000.0 psi Min Vert Steel %
8,000 in Phi 0.900
0.0020
Min Horiz Steel %
5
0.0012
Width 12,000 in Base Fixity
11.000 in
5.750 in Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000 Parapet Seismic Factor 0.3000 150.0 LL & ST Together
0 %
145.00 DCf Using: UBC Sec. 1914.0 method ... Exact. Non-Iterated
Lateral Loads Vertical Loads Wind Load 18.000 psf Uniform DL
Uniform LL Point Load ... height ... load type Seismic
75.00 Wft 100.00 Wfi
7.500 in
3,165.00 #/ft
450.00 #/ft
Ibs ... eccentricity
ft
Concentric DL Concentric LL
Lateral Load 130.50 wn ... distance to top ... distance to bot
9.000 ft
ft ... load type Seismic "I" Magnifier 1.000
1.000 Seismic Wind "I" Magnifier I Wall Analysis "" 1
For Factored Load Stresses For Service Load Deflections Seismic Wind
Basic Den w/o P-Delta
Basic M w/o P-Delta
Moment Excess of Mcr
Max. P-Delta Deflection
Max P-Delta Moment
Seismic
0.104 0.016 in 0.075 54,924.0 7,869.5 in-# 0.012 in
39,561.4
28,613.4 6,223.8 in# 0.0 in-# 9,807.3
1.367 1.422 in 0.0 in#
0.201
63,667.6 0.012 in 14,953.7 in# 44,861.6 11,592.8 in#
Maximum Allow Vertical Bar Spacing 18,000 in
Maximum Allow Horizontal Bar Spacing 18,000 in Parapet Bar Spacing Req'd : SEISMIC 18,000 in
Parapet Bar Spacing Req'd : WIND 18,000 in
Wall Design OK
1.50ft parapet, 8.00in thick with #5 bars at 11 .OOin on center, d= 5.75in, fc = 3,OOO.Ops
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Maximum Iterated Moment : Mu 35,480.64 in-#
Moment Capacity Maximum Iterated Deflection
58,944.25 in#
0.038 in
Deflection Limit 1.160 in
Mn * Phi : Moment Capacity
Applied: Mu @ Mid-Span Applied: Mu @ Top of Wall I Max Iterated Service Load Deflection
Actual Deflection Ratio
Seismic 117.822.61 in-# 113,574.49 in-#
63,667.61 in-# 14,953.71 in-#
2,385.60 in-# 1,856.70 in-#
Wind
I Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 Rho Bal 0.0049
0.0128
0.20 in
864 : 1
0.01 in
13,966 : 1
0.0049
0.0128
Actual Axial Stress : (Pw + Po ) / Ag 48.29 psi
Allowable Axial Stress = 0.4 * fm 120.00 psi 46.29 psi
120.00 psi
(c) 1983-97 ENERCALC c:!enercalcUotlO6.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Title : Lot 108 Redesign Dsgnr: Date: Description :
scone !
Job # 98244
Fax: (619) 485-6201 "-r-.
Tilt-Up Wall Panel Design
I Analvsis Data
E n=Es/Ec
Fr =
Ht / Thk Ratio
Values for Mn Calculation ...
As:eff= [Pu:tot + AsFyYFy
a : (AsFy + Pu)/(.85 fc b) c=a/.85 lgross
lcracked
I-eff (ACI methods only)
Phi: Capacity Reduction Mn = As:eff Fy (d - a/2)
3,122,018.6 psi 9.29
273.86 psi
21.75
I Additional Values
Seismic
0.446 in
0.875 in
512.000 in4
1.030 in
96.75 in4
0.00 in4
130,914.01 in#
0.900
Sgross 128.000 in3
Mcr = S * Fr
Rho: Bar Reinf Pct
35,054.2 in#
0.0214
Wind
0.421 in
0.826 in
0.972 in
512.00 in4
93.03 in4
0.900 0.00 in4
126,193.88 in#
t I Loads used for analysis
Wall Weight 96.667 psf Wall Wt * Wail Seismic Factor 29.000 psf Applied Axial Load 5.306.00 4.103.25 Wft
Factored Loads Seismic Wind
Wail Wt Parapet Seismic Factor 29,000 psf Lateral Wall Weight 1i184.17
Service Applied Awial Load 3,790.00 #/ft Total Lateral Loads 6,490.16 4,991.37#/ft
Service Wt @ Max Mom
Total Service Axial Loads 4,635.83 #In 845.03 #/ft
'888.12 Wrt
I ACI Factors (per ACI. applied internally to entered loads)
ACI 9-1 & 9-2 DL 1.400 ACi 9-2 Group Factor 0.750 UBC 1921.2.7"1.4"Factor 1.400
ACI 9-1 8 9-2 LL
ACI 9-1 & 9-2 ST
1.700 ACi 9-3 Dead Load Factor 0.900 UBC 1921.2.7"0.9" Factor 0,900
1.700 ACI 9-3 Short Term Factor 1.300
1
.... seismic=ST': 1,100
(c) 1983-97 ENERCALC c:!enercalcYotl06.ecw KW-0602755, V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Dsgnr: Dale: Descrlplion :
Scope :
Tilt-Up Wall Panel Design 32 \
____ ~ ~~ I General Information
~ ~ ~~~ 1
Description Line 1 & 6, Floor: 4-0 Leg
Clear Height
Parapet Height
Thickness 8.000 in
Bar Size 5 Bar Spacing Bar Depth 11.000 in 5.750 in
Max Defl. Ratio
Concrete Weight
150.0
145.00 pcf
16.000 n
0.000 n PC 3,000.0 psi Seismic Zone
FY
4
Phi
60,000.0 psi
0.900
Min Vert Steel % 0.0020
Min Horiz Steel Oh
Width 12.000 in
0.0012
Base Fixity
Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000
LL 8 ST Together
Parapet Seismic Factor 0.3000
Using: UBC Sec. 1914.0 method ... Exact. Non-Iterated
0%
i Loads 1
Lateral Loads Wind Load
Point Load ... height ... load type
Lateral Load ... distance to top ... distance to bot
~~ ~~~~
Vertical Loads
18.000 psf Uniform DL 286.00 #In
Uniform LL 360.00 #In ... eccentricity 7.000 in ibs n
Seismic Concentric DL 2,168.00 #/ft
Concentric LL 900.00 #/n
72.50 #/n 1o.ooo n n Seismic "111 Magnifier 1.000 ... load type Seismic Wind "111 Magnifier 1.000
Wall Analysis t
For Factored Load Stresses For Service Load Deflections Seismic y.@ - Seismic ~ Wind Basic Defl w/o P-Delta 0.106 0.029 in 0.080 0.023 in Basic M wlo P-Delta 45,421.4 11,669.9 in-#
Moment Excess of Mcr 20,754.2
33,603.1 9,357.8 in#
Max. P-Delta Deflection 0.0 in-# 4,253.3 0.0 in#
Max P-Delta Moment 55,808.5 20,170.1 in-# 39,307.5 15,014.1 in#
Maximum Allow Vertical Bar Spacing
Maximum Ailow Horizontal Bar Spacing 18,000 in
18,000 in Parapet Bar Spacing Req'd : SElSMiC 18,000 in
Parapet Bar Spacing Req'd : WIND 18.000 in
Wall Design OM
~~~ ~
1.665 1.722 in 0.155 0.023 in
0.0Oft parapet, 8.00in thick with #5 bars at 11.00in on center. d= 5.75in. fc = 3,000.0ps
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Maximum Iterated Moment : Mu
Moment Capacity
35,480.64 in#
58,944.25 in-#
Maximum Iterated Deflection
Deflection Limit
0.038 in
1.160 in
Mn * Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @ Top of Wall
Max Iterated Service Load Deflection Actual Deflection Ratio
117,229.40 in-# Seismic
55,808.48 in-#
6,330.80 in-#
1,238 : 1
0.16 in
I Actual Reinforcing Percentage 0.0049
Allowable Max. Reinf. Percent = 0.5 Rho Bal 0.0128 1 Actual Axial Stress : (Pw + Po ) / Ag
Allowable Axial Stress 0.4 * fm 120.00 Dsi
46.72 psi
113,579.42 in4 Wind
20.170.08 in4
5,315.10 in-#
0.02 in
6,291 : 1
0.0049
0.0128
120.00 osi
46.72 psi
(c) 1983-97 ENERCALC c:knercalcVoll06.ecw KW-0602755, V5.0.2, 1 Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201 Drgnr: Dale:
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Description :
Scope :
Tilt-Up Wall Panel Design 21
1 Analysis Data L
E 3,122,018.6 psi
n = Es / Ec 9.29 Sgross 128.000 in3
Mcr = S * Fr 35.054.2 in#
Ht / Thk Ratio
Fr =
Values for Mn Calculation... As:eff= IPu:tot + AsFvVFv
273.86 psi
24.00
Seismic
0.443 in
Rho: Bar Reinf Pct
Wind
0 471 in
0.0214
a : (AsF~. + pu)1(.85 Fi bj 0.868 in c~a1.85 0.828 in
1,022 in 0.972 in
lgross 512.000 in4
lcracked 96.23 in4 512.00 in4
I-eff (ACI methods only) 0.00 in4
93.03 in4
Phi: Capacity Reduction 0.900 0.00 In4
Mn = As:eff Fy (d - an) 130,254.89 in# 126,199.35 in#
0.900
- . . - . . . .
1 Additional Values - 1 Loads used for analysis
Wall Weight 96.667 psf
Wall Wt * Wall Seismic Factor 29,000 psf Applied Axial Load 5,196.80 4,181.10 #/A
Wall Wt Parapet Seismic Factor 29,000 psf
Service Applied Axial Load Lateral Wall Weight 1,082.67
Service Wt @ Max Mom
Total Service Axial Loads 4,485.33 wn
LAC1 Factors (per ACI, applied internally to entered loads)
Factored Loads Seismic Wind
3,712.00 wn Total Lateral Loads 6,279.46 4,993.10wA 812.00 #In
773.33 wn
1 ACI 9-1 8 9-2 DL
ACI 9-1 8 9-2 LL
1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4" Factor 1.400
ACI 9-1 8 9-2 ST
1.700
1.700
ACI 9-3 Dead Load Factor
ACI 9-3 Short Term Factor 1.300
0.900 UBC 1921.2.7 "0.9" Factor 0.900
.... seismic= ST': 1.100
(C) 198597 ENERCALC "" c:\enercalcYotl06.ecw KW-0602755, V5.0.2. 1Jun-I997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Title : Lot 108 Redesign Drgnr: Date: Dercrlpllon :
scnnc !
Job # 98244
Fax: (619) 485-6201 "-0".
L Tilt-Up Wall Panel Design 34
I General Information 1
Description Line 1 & 6, Floor: No Openings
Clear Height
Parapet Height
16.000 n fc 3,000.0 psi Seismic Zone
0.000 n 4
Thickness 8.000 in FY 60,000.0 psi Phi 0.900 Min Vert Steel Oh 0.0020 Min Horiz Steel %
Bar Size
0.0012 5 Bar Spacing
Width
14.000 in
12.000 in Base Fixity 0%
Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000 Bar Depth 3.625 in
Max Defl. Ratio 150.0 Parapet Seismic Factor 0.3000
Concrete Weight 145.00 pcf Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated LL & ST Together
1 Loads t
Lateral Loads Wind Load
Point Load Ibs ... height ft ... load type Seismic Concentric DL
Concentric LL
#/ft
Vertical Loads
Uniform LL ... eccentricity 7.000 in
18.000 psf Uniform DL 286.00 #/R
360.00 #In
#/ft
#/R Lateral Load ... distance to too fl ... distance to boi ... load type
~ ~~ ~~
R Seismic "111 Magnifier 1.000
Seismic Wind "111 Magnifier 1.000
[Wall Analysis L
For Factored Load Stresses For Service Load Deflections
Basic Defl w/o P-Delta 0.041 0.029 in Basic M w/o P-Delta 17.022.9 13 sm n 9 1S7 R in2 11.669.9 in-#
Seismic Wind Seismic Wind
0.033 0.023 in
Moment Excess of Mcr
Max. P-Delta Deflection
Max P-Delta Moment
, ~~ ~ 0.0 0.0 in# 0.0 0.0 in#
2.876 2.921 in
22,728.4
0.033
16.188.8 in# 15,311.7 0.023 in 11,135.4 in#
. -, - - -. - -,--..- ~ ....
Maximum Allow Vertical Bar Spacing
Maximum Allow Horizontal Bar Spacing 18,000 in
18.000 in Parapet Bar Spacing Req'd : SEISMIC 18,000 in
Parapet Bar Spacing Req'd : WIND 18.000 in
Wall Design OK -i 16.00ff clear height, O.OOff parapet, 8.00in thick with #5 bars at 14.00in on center, d= 3.63in. f'c = 3,000.0p~
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Maximum Iterated Moment : Mu 35,480.64 in# Maximum Iterated Deflection
Moment Capacity 0.038 in
58,944.25 in# Deflection Limit 1.160 in
Mn * Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @ Top of Wall
Seismic
53,098.06 in-#
22.728.37 in-#
6.330.80 in-#
Max Iterated Service Load Deflection
Actual Deflection Ratio 5,770 : 1 0.03 in
Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 *Rho Bal 0.0061
0.0128
52,098.66 in-#
16,186.75 in-#
5,315.10 in-#
Wind
8,291 : 1
0.02 in
0.0061
0.0128
Actual Axial Stress : (Pw + Po ) I Ag 14.78 psi
Allowable Axial Stress = 0.4 Pm 120.00 psi 14.78 psi 120.00 psi ____ ~. i
(C) 1983-97 ENERCALC c:\enercalcYotl06.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Tltle : Lot 106 Redesign
Drgnr: Date: Description :
Job # 98244
SEOm? :
Fax: (619) 485-6201 ." r- -
" Tilt-Up Wall Panel Design
LAnalysis Data I
E 3,122,018.6 psi n = Es / Ec 9.29
Fr = 273.86 psi Ht / Thk Ratio 24.00
Sgross 128.000 in3 Mcr = S * Fr
Rho: Bar Reinf Pct
35,054.2 in#
0.0214
Values for Mn Calculation...
As:eff= [Pu:tot + AsFy]/Fy
a : (AsFy + Pu)/(.85 fc b)
0.299 in
0.586 in
c=a/.85 0.689 in
Seismic Wind
0.292 in
0.572 in
0.673 in
lgross 512.000 in4 512.00 in4
lcracked
I-eff (ACI methods only)
24.84 in4
Phi: Capacity Reduction 0.900
0.00 in4
Mn = As:eff Fy (d - a/2)
0.900
58,997.85 in# 57,887.40 in#
25.23 in4
0.00 in4
1 Additional Values i
~ ~ ~~ ~~ ~ ~ ~ ~~ ~~~~ ~ ~~ ~~~ ~ ~ Loads used for analysls Factored Loads
Wall Weight 96.667 psf Seismic Wind
Wall Wt *Wall Seismic Factor
Wall Wt * Parapet Seismic Factor 29.000 psf
29.000 psf Applied Axial Load 904.40
Lateral Wall Weight 1,082.67
759.30 #/fl
Service Applied Axial Load
812.00 #/fl
646.00 #/fl Total Lateral Loads 1.987.07 1,571.30#/ft
Service Wt @ Max Mom
Total Service Axial Loads
773.33 #/fl
1.419.33 #/ft
ACI Factors (per ACI, applied internally to entered loads) I ACI 9-1 8 9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4" Factor 1.400
ACI 9-1 8 9-2 LL
ACI 9-1 8 9-2 ST
1.700
1.700
ACI 9-3 Dead Load Factor
ACI 9-3 Short Term Factor
0.900 UBC 1921.2.7 "0.9 Factor 0,900
.... seismic=ST': 1.100
1.300
(e) 1983-97 ENERCALC c:knercalcUotlO6.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Title : Lot log Redesign Drgnr: Date: Description :
scnoe !
Job # 98244
Fax: (619) 485-6201 "-8".
Tilt-Up Wall Panel Design 3L h L - "
LGeneral Information 1
Description Line G, Roof: No Openings
Clear Height
Thickness
Parapet Height
Bar Size
Bar Spacing Bar Depth
Max Defl. Ratio
Concrete Weight
13.800 n 2.200 n
8.000 in
14.000 in
3.625 in
150.0
5
145.00 DCf
PC 3,000.0 psi Seismic Zone
FY
4
Phi
60,000.0 psi
0.900
Min Vert Steel % 0.0020
Min Horii Steel %
Width 12.000 in
0.0012
Base Fixity
Parapet Weight Counteracts Midd Wail Seismic Factor 0.3000 Parapet Seismic Factor 0.3000
Using: UBC Sec. 1914.0 method ... Exact. Non-Iterated LL 8 ST Together
0%
I Loads I
Lateral Loads Vertical Loads Wind Load 18.000 psf Uniform DL 439.00 Hn
Point Load
Uniform LL 468.00 #/it
... height ... load type Seismic Concentric DL #/fl
Ibs ... eccentricity 7.500 in n
#/n
n
Concentric LL
Lateral Load
#/n
... distance to top n ... distance to bot ... load type Seismic Wind "I' Magnifier
Seismic "I" Magnifier 1.000
1.000
[Wall Analysis
Moment Excess of Mcr 0.0
Max. P-Delta Deflection 2.149 0.0 in# 0.0 0.0 in#
2.189 in
Max P-Delta Moment 18,729.2 14,829.1 in# 0.021 13,451.0 0.016 in 10,598.0 in#
Maximum Allow Vertical Bar Spacing 18.000 in Parapet Bar Spacing Req'd : SEISMIC 18.000 in
Maximum Allow Horizontal Bar SDacina 18.000 in Paraoet Bar Soacino Redd : WIND 18.000 in " - I,
Wall Design OK
13.8Oft clear height, 2.20ft parapet, 8.00in thick with #5 bars at 14.00in on center, d= 3.63in, fc = 3.000.0ps
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Maximum Iterated Moment : Mu 35,480.64 in-#
Moment Capacity
Maximum Iterated Deflection
58,944.25 in-#
0.038 in
Deflection Limit 1.160 in
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Mn Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @ Top of Wall
Max Iterated Service Load Deflection
Actual Deflection Ratio
Seismic 54,327.20 in-#
18,729.21 in-#
10,702.52 in-#
7,799 ; 1
0.02 in
I Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 Rho Bai 0.0061
0.0128
53,084.23 in-#
14,829.07 in-#
8.598.84 in-#
10,362 : 1
0.02 in
0.0061
0.0128
Wind
Actual Axial Stress : (Pw + Po ) / Ag 18.61 psi
Allowable Axial Stress 0.4 * fm 120.00 psi 18.61 psi 120.00 psi
(c) 1983-97 ENERCALC c:\enercalcVotl06.ecw KW-0602755, V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Title : Lot 106 Redesign Dsgnr: Date: Description :
scone !
Job # 98244
Fax: (619) 485-6201 ." r-.
L Tilt-Up Wall Panel Design 31
1 Analysis Data 1
E 3.122.018.6 psi n=Es/Ec 9.29 Fr = 273.86 psi Ht / Thk Ratio 20.70
Sgross 128.000 in3
Mcr = S * Fr
Rho: Bar Reinf Pct
35,054.2 in#
0.0214
Values for Mn Calculation ... Seismic
As:eff= [Pu:tot + AsFy]/Fy
a : (AsFy + Pu)/(.85 fc b)
0.307 in 0.299 in
c=a/.85
0.603 in 0.586 in
0.709 in
lgross 512.000 in4 512.00 in4
0.689 in
lcracked
I-eff (ACI methods only)
25.70 in4 25.23 in4
0.00 in4 0.00 in4 Phi: Capacity Reduction 0.900 0.900 Mn = As:eff Fy (d - a/2) 60,363.56 in-# 58,982.48 in#
Wind
[ Additional Values - 1 Loads used for analysis
Wall Weight Factored Loads 96.667 psf Seismic Wail Wt Wall Seismic Factor
Wind
29.000 psf Wall Wt * Parapet Seismic Factor 29,000 psf Applied Axial Load 1,269.80 1,057.65 #In
Lateral Wall Weight 1,231.53
Service Applied Axial Load 907.00 #In 923.65 #/n
Service Wt @ Max Mom 879.67 #/fl Total Lateral Loads 2,501.33 1,981.30#/fl
Total Service Axial Loads 1.786.67 #/n I ACI Factors (per ACI. applied internally to entered loads) ~" 1 ACI 9-1 8 9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4" Factor 1.400
ACI 9-1 8 9-2 LL
ACI 9-1 8 9-2 ST
1.700 ACI 9-3 Dead Load Factor
1.700 ACI 9-3 Short Term Factor 1.300
0.900 UBC 1921.2.7"0.9 Factor 0.900
.... seismic = ST : 1.100
(c) 1983-97 ENERCALC c:\enercalcVoll06.ecw KW-0602755, V5.0.2. 1 Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Dsgnr: Date: Description :
Scope :
L Tilt-Up Wall Panel Design 38
1 General Information i
Description Line G. Roof: 2-0 Leg
Clear Height 13.800 n PC 3,000.0 psi Seismic Zone
Parapet Height 2.200 n 4
Thickness 8.000 in FY 60,000.0 psi Min Vert Steel % Phi 0.0020
0.900
Bar Size
Min Horiz Steel % 0.0012
5 Bar Spacing 11.000 in Width
Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000
12.000 in Base Fixity 0%
Bar Depth 5.750 in
Max Defl. Ratio Parapet Seismic Factor 0.3000 150.0 Concrete Weight 145.00 DCf LL 8 ST Together
Usina: UBC Sec. 1914.0 method ... Exact. Non-Iterated
LLoads 1
Lateral Loads
Wind Load
Point Load ibs ... height n ... load type Seismic Concentric DL
Vertical Loads 18.000 psf Uniform DL 439.00 #/n
Uniform LL 468.00 #/R ... eccentricity 7.500 in
Concentric LL 2,106.00 #/R
5,019.00 #/ft
Lateral Load ... distance to top ... distance to bot n Seismic "I" Magnifier 1.000 ... load type Seismic Wind "I" Magnifier 1.000
130.50 #In 9.000 n
1 Wall Analysis I
For Factored Load Stresses For Service Load Deflections &jy& Wind
53,339.7 10,692.1 in# 39,714.4
Basic Defi w/o P-Delta 0.093 0.020 in Basic M w/o P-Delta
Moment Excess of Mcr 33,614.5
8,760.0 in#
Max. P-Delta Deflection 0.0 in# 14,460.0
1.237 0.0 in# 1.301 in Max P-Delta Moment 0.211
88.668.8 23,286.7 in# 49,514.2 18,281.3 in#
0.016 in
Maximum Allow Vertical Bar Spacing 18.000 in
Maximum Allow Horizontal Bar Spacing 18,000 in Parapet Bar Spacing Req'd : SEISMIC 18,000 in
Parapet Bar Spacing Req'd : WIND 18.000 in
Wall Design OK
13.80fl clear height, 2.20fl parapet, 8.00in thick with #5 bars at 11 .OOin on center, d= 5.7511, fc = 3,000.0ps
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
&jy& Wind
0.070 0.016 in
Maximum Iterated Moment : Mu
Moment Capacity
35,480.64 in4
58.944.25 in-#
Maximum Iterated Deflection
Deflection Limit
0.038 in
1.160 in
Mn Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @ Top of Wall
Max Iterated Service Load Deflection Actual Deflection Ratio
Seismic 134.130.65 in-# 127,339.86 in-#
68,668.78 in-# 23.286.66 in-#
10,702.52 in-# 8,598.84 in-#
Wind
0.21 in
786 : 1 I Actual Reinforcing Percentage Allowable Max. Reinf. Percent = 0.5 ' Rho Bal 0.0049
0.0128
10,362 : 1
0.02 in
0.0049 0.0128
Actual Axial Stress : (Pw + Po ) I Ag 92.83 psi
Allowable Axial Stress = 0.4 fm 120.00 psi 92.83 psi
120.00 psi
(c) 198597 ENERCALC c:\enercaic\lotlOG.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign
16959 Bernard0 Center Drive #201 Osgnr: Date:
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Job # 98244
Description :
Scope :
L Tilt-Up Wall Panel Design 31
1 LAnalysis Data
E 3,122,018.6 psi Saross 128.000 in3 n=Es/Ec
Fr =
Ht I Thk Ratio
Values for Mn Calculation ... As:eff= [Pu:tot + AsFyllFy a : (AsFy + Pu)/(.85 fc b)
273.86 psi
9.29
20.70
Seismic
0.546 in 1.071 in
Mir = S * Fr
Rho: Bar Reinf Pct 0.0214
~~ ~
35,054.2 in#
Wind
0.504 in
0.988 in c=a/.85
lgross
1.260 in
512.000 in4 1.162 in
lcracked 512.00 in4 110.28 in4
I-eff (ACI methods only) 0.00 in4 104.70 in4
Phi: Capacity Reduction 0.00 in4
Mn = As:eff Fy (d - a/2) 149,034.06 in# 141,400.74 in# 0.900 0.900
I Additional Values c Loads used for analysis
Wall Weight
Wall Wt *Wall Seismic Factor 29.000 psf
96.667 psf
Applied Axial Load 11,244.80 9,012.75 #/fl Wail Wt * Parapet Seismic Factor 29,000 psf
Service Applied Axial Load 8,032.00 #/fl
Lateral Wall Weight 1,231.53
Total Lateral Loads 12,476.33 9,936.40#/fl
923.65 #/fl
Total Service Axial Loads
Service Wt @ Max Mom 879.67 #/fl
8.911.66 wn
Factored Loads Seismic Wind
LACI Factors (per ACI, applied internally to entered loads)
~,~ ~.~
ACI 9-1 a 9-2 DL c 1.400
ACI 9-1 8 9-2 LL 1.700 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4 Factor 1.400
ACI 9-1 & 9-2 ST 1.700
ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7 "0.9 Factor 0,900
ACI 9-3 Short Term Factor 1.300 .... seismic=ST*: 1.100
(C) 1983-97 ENERCALC ". c:\enercalcuotl06.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Fax: (619) 485-6201
Title : Lot 106 Redesign Dsgnr: Date: Description :
Scope :
Job # 98244
I Tilt-Up Wall Panel Design 40)
[ General Information 1 Description Line G, Roof: 4-0 Leg
Clear Height
Thickness Parapet Height
Bar Size
Bar Spacing Bar Depth Max Defl. Ratio
Concrete Weight
13.800 fl
2.200 n fc 3,000.0 psi
FY 60,000.0 psi
Seismic Zone
Min Vert Steel %
4
8.000 in Phi
0.0020
5 Width 12.000 in
0.900 Min Horiz Steel % 0.0012
Base Fixity 14.000 in
3.625 in Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000
Parapet Seismic Factor 0.3000 150.0
145.00 pcf Using: UBC Sec. 1914.0 method ... Exact. Non-Iterated LL & ST Together
0%
I Loads I
Lateral Loads Wind Load
Point Load
Vertical Loads 18.000 psf Uniform DL 439.00 #/ft
Uniform LL
ibs ... eccentricitv
468.00 #In
7.500 in ... height ft ... load type Seismic
Lateral Load ... distance to top 32.60 #/ft
... distance to bot
9.000 n n
Concentric LL
Concentric DL 1,255.00 #/ft
527.00 #In
Seismic "111 Maanifier 1.000 ... load type Seismic Wind "111 Magnker 1.000
~~~
I Wall Analysis
For Factored Load Stresses For Service Load Deflections
Basic Defl wlo P-Deita 0.041 0.020 in Basic M w/o P-Delta 23,214.1 10,692.1 in-# 18.324.4 8.760.0 in#
Wind - Seismic
0.033 0.016 in
Moment Excess of Mcr 0.0 0.0 in-# 0.0 0.0 in#
Max. P-Delta Deflection
Max P-Delta Moment 34,166.2 19,398.5 in-# 22,263.3 12,491.5 in#
Maximum Allow Vertical Bar Spacing 18,000 in Parapet Bar Spacing Req'd : SEISMIC 18.000 in
Maximum Allow Horizontal Bar Spacing 18,000 in Parapet Bar Spacing Req'd : WIND 18,000 in
Wall Design OK
13.80fl clear height, 2.20ft parapet, 8.00in thick with #5 bars at 14.00in on center, d= 3.63in, fc = 3,000.0ps
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
2.196 2.266 in 0.033 0.016 in
~~
Maximum iterated Moment : Mu
Moment Capacity 35,480.64 in-#
58,944.25 in#
Maximum Iterated Deflection
Deflection Limit
0.038 in
1.160 in
Mn * Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @ Top of Wall
Max Iterated Service Load Deflection
Actual Deflection Ratio
Seismic 60,179.59 in-#
34,166.16 in-#
10,702.52 in-#
4,961 : 1
0.03 in
I Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 *Rho Bal 0.0061
0.0126
57,796.90 in-#
19,398.50 in-#
8.598.84 in-#
10,362 : 1
0.02 in
0.0061
0.0128
Wind
Actual Axial Stress : (Pw + Po ) IAg 37.17 psi
Allowable Axial Stress = 0.4 fm 37.17 psi 120.00 psi 120.00 psi
(c) 1983-97 ENERCALC c:knercalcUo1106.ecw KW-0602755. V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Dsgnr: Date: Description :
Scope :
Tilt-UD Wall Panel Desian 41 c
LAnalysis Data I
n=EsIEc 9.29 Mcr = S Fr 35,054.2 in#
128.000 in3
Fr = 273.86 psi Rho: Bar Reinf Pct 0.0214
Ht I Thk Ratio
E 3,122,018.6 psi Sgross
20.70
Values for Mn Calculation.. . As:eff= [Pu:tot + AsFyYFy
a : (AsFy + Pu)1(.85 PC bl
c = a I .85
lgross
lcracked
I-eff (Act methods only)
Phi: Capacity Reduction
Mn = As:eff Fv Id - al2)
Seismic
0.349 in
0.684 in
0.805 in
512.000 in4
27.87 in4
0.900
0.00 in4
66.866.21 in#
Wind
0.332 in
0.651 in
512.00 In4
0.766 in
27.00 in4
0.00 in4
64.218.77 in# 0.900
..
Additional Values "
~~
1 Loads used for analysis ~ ~ ~~~
Wall Weight Factored Loads 96.667 psf Seismic
Wall Wt * Wall Seismic Factor
Wind
29.000 osf ADDlied Axial Load 3.764.60 3.047.32 illit
Wall Wt * Parapet Seismic Factor 29.000 psf Laieral Wall Weight 1:231.53
Service Applied Axial Load 2,689.00 #Kt
923.65 #lft
Service Wt @ Max Mom Total Lateral Loads 4,996.13 3,970.97Wft
Total Service Axial Loads
879.67 #In
3,568.67 #lft
~~ ~.~ ~~~ ~
I ACI Factors (per ACI, applied internally to entered loads) 1 ACI 9-1 & 9-2 DL
ACI 9-1 8 9-2 LL
1.400 ACI 9-2 Group Factor
1.700 ACI 9-3 Dead Load Factor
0.750 UBC 1921.2.7"l.Y Factor 1.400
0.900 UBC 1921.2.7 "0.9" Factor 0,900
1.700 ACI 9-3 Short Term Factor 1.300 ACI 9-1 a 9-2 ST .... seismic = ST * : 1.100
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Tille : Lot 106 Redesign Dsgnr: Date: Description :
Job # 98244
Cmnm. Fax: (619) 485-6201 "-p-.
Tilt-Up Wall Panel Design
LGeneral Information I
Description Line G, Floor: 4'-0" Leg (1)
Clear Height 16.000 ft PC
Parapet Height 0.000 ft
4
Thickness 8.000 in 60,000.0 psi Min Vert Steel % 0.0020
Phi
Bar Size 5
0.900 Min Horiz Steel Oh 0.0012
Bar Spacing Width
11.000 in
12.000 in Base Fixity 0%
Bar Depth Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000 5.750 in ParaDet Seismic Factor 0.3000
3,000.0 psi Seismic Zone
FY
Max Defl. Ratio
Concrete Weight
150.0 LL &'ST Together
145.00 pcf Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated I Loads i I I
Lateral Loads Vertical Loads Wind Load 18.000 psf Uniform DL
Uniform LL Point Load Ibs ... eccentricity 7.500 in
1,089.00 #/ft
1,268.00 #/ft
... height ... load type
n
Seismic Concentric DL
Concentric LL 4,172.00 tvn
3,170.00 #/n Lateral Load ... distance to top 1o.ooo n ... distance to bot n ... load type
72.50 #In
Seismic "I" Magnifier 1.000 Wind "I' Magnifier 1.000 Seismic I Wall Analysis I
For Factored Load Stresses For Service Load Deflections Seismic - Wind Seismic Wind Basic Defl w/o P-Deita 0.119 0.051 in 0.099 0.042 in
Basic M w/o P-Delta
Moment Excess of Mcr
49,444.1
38,762.7
22,201.1 in-# 39,984.7 18,576.4 in#
5,980.1 in# Max. P-Deita Deflection 18,335.1 0.0 in#
Max P-Delta Moment 73,816.9 1.665 1.749 in 0.323
41,034.4 in# 53,389.3
0.042 in
30,110.4 in#
Maximum Allow Vertical Bar Spacing 18.000 in
Maximum Ailow Horizontal Bar Spacing 18,000 in Parapet Bar Spacing Req'd : SEISMIC 18.000 in
Parapet Bar Spacing Req'd : WIND 18.000 in
Wall Design OK
0.00fl parapet, 8.00in thick with #5 bars at 11 .OOin on center, d= 5.7511, fc = 3,OOO.Ops
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Maximum Iterated Moment : Mu
Moment Capacity
35.480.64 in-#
58,944.25 in#
Maximum Iterated Deflection
Deflection Limit
0.038 in
1.160 in
Mn * Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @ Top of Wall
139,820.49 in-# Seismic
73,816.95 in-#
24,748.49 in-#
Max Iterated Service Load Deflection 0.32 in
Actual Deflection Ratio 595 : 1
Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 Rho Bal 0.0049
0.0128 I Actual Axial Stress : (Pw + Po ) / Ag
Allowable Axial Stress = 0.4 * Pm 109.09 psi
120.00 mi
132.657.00 in-% Wind
41,034.36 in-#
20,701.12 in-#
.. . ..
4,522 : 1
0.04 in
0.0049
0.0128
109.09 psi
120.00 nsi
Firouzi Consulting Engineers, Inc Title : Lot IC6 Redesign
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Job # 98244 Dsgnr: Date: Description :
Scope :
L Tilt-Up Wall Panel Design 43
1 [ Analysis Data
E n=Es/Ec
Fr = 273.86 psi
Ht I Thk Ratio
3,122,018.6 psi Sgross 9.29
24.00
128.000 in3
35,054.2 in# Mcr = S Fr
Rho: Bar Reinf Pct 0.0214
Values for Mn Calculation ... Seismic
As:eff= [Pu:tot + AsFylIFy 0.583 in
Wind
a : (AsFy + Pu)I(.85 fc b)
0.538 in
c = a I .85
1.142 in 1.055 in 1.344 in
lgross 1.241 in 512.000 in4 lcracked 512.00 in4 114.76 in4
I-eff (ACI methods only)
109.26 in4
0.00 in4
Phi: Capacity Reduction 0.00 in4
Mn = As:eff Fy (d - aI2) 155,356.10 in-# 147,618.89 in#
0.900 0.900
LAdditional Values 1 Loads used for analysis
Wall Weight 96.667 psf Wall Wt *Wall Seismic Factor 29.000 psf Applied Axial Load 13,578.59 11,182.50 #/R Wall Wt * Parapet Seismic Factor 29,000 psf Service Applied Axial Load 9,699.00 #In Lateral Wail Weight 1,082.67
Total Lateral Loads 14,661.26 11,994.50#/ff
812.00 #/ft
Service Wt @ Max Mom
Total Service Axial Loads 10,472.33 #In
Factored Loads Seismic Wind
773.33 #In
1 ACI Factors (per ACi, applied internally to entered loads)
ACI 9-1 & 9-2 DL
ACI 9-1 & 9-2 LL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"l.V Factor 1.400
ACI 9-1 & 9-2 ST
1.700
1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7"0.9 Factor 0.900
ACI 9-3 Short Term Factor 1.300
t
..seismic = ST : 1.100
(C) 1983-97 ENERCALC c:\enercalcVotl06.ecw KW-0602755, V5.0.2.1Jun-1997
Firouri Consulting Engineers, Inc Title : Lot 106 Redesign
16959 Bernard0 Center Drive #201 Dsgnr:
San Diego, California 92128
Fax: (619) 485-6201
Job # 98244 Date: Description :
Scope : Phone: (619) 485-6227
L Tilt-Up Wall Panel Design 44
General Information - ..__.__ 1
Description Line G, Floor: 4'-0 Leg (2)
Clear Height 16.000 ft PC 3,000.0 psi Seismic Zone
Parapet Height 0.000 ft
4
Thickness FY 60,000.0 psi Min Vert Steel % 0.0020
Bar Size 12.000 in 5
Phi 0.900 Min Horiz Steel ?4 0.0012
Width
Bar Spacing
12.000 in
11.000 in
Base Fixity 0%
Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000 Bar Depth Max Den. Ratio 9.750 in Parapet Seismic Factor 0.3000
Concrete Weight
150.0 LL 8 ST Together
145.00 pcf Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
LLoads 1
Lateral Loads Vertical Loads Wind Load 18.000 psf Uniform DL
Uniform LC
Point Load Ibs ... eccentricity 7.000 in
2,998.00 #Iff
3,393.00 wn
... load type
... height n
Seismic Concentric DL
Concentric LL
9,670.00 #In
8,483.00 #/n
Lateral Load 108.80 #/ft ... distance to top mooo n ... distance to bot ... load type Seismic n Wind "1" Magnifier Seismic "I" Magnifier 1.000
1.000 t
For Factored Load Stresses For Service Load Deflections Seismic Wind Basic Den wlo P-Delta - 0.058 0.029 in
Seismic Wind
0.052 0.024 in
Basic M w/o P-Delta 80,116.1 52,317.8 in#
Moment Excess of Mcr 30,809.5
69,576.4 44,737.0 in#
0.0 in# Max. P-Delta Deflection 0.822 23,408.8
0.886 in 0.0 in#
Max P-Delta Moment 109,681.5 66,127.5 in# 0.120 0.024 in
102,280.9 65,323.4 in#
Maximum Allow Vertical Bar Spacing
Maximum Allow Horizontal Bar Spacing 18,000 in
12.917 in Parapet Bar Spacing Req'd : SEISMIC 12.917 in
Parapet Bar Spacing Req'd : WiND 12.917 in
Wall Design OK
. ~~ ~
O.OOft parapet, 12.00in thick with #5 bars at 11.00in on center, d= 9.75in. fc = 3,000.0p
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Maximum Iterated Moment : Mu 35,480.64 in4
Moment Capacity
Maximum Iterated Deflection 0.038 in
1.160 in 58,944.25 in-# Deflection Limit
Mn * Phi : Moment Capacity
Applied: Mu @ Mid-Span Applied: Mu @Top of Wall
Max Iterated Service Load Deflection
Actual Deflection Ratio
Seismic 325.800.72 in-# 301,529.24 in-#
109.681.50 in-# 66,127.47 in-#
62.631.77 in-# 52.317.80 in-#
Wind
1,603 : 1
0.12 in
I Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 * Rho Bal 0.0029
0.0128
7,864 : 1
0.02 in
0.0029 0.0128
Actual Axial Stress : (Pw + Po ) I Ag
Allowable Axial Stress = 0.4 * Prn
178.50 psi 178.50 psi
120.00 psi 120.00 psi I
(c) 1983-97 ENERCALC c:\enercab~otl06.ecw KW.0602755. V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227 Fax: (619) 485-6201
Title : Lot 106 Redesign Dsgnr: Date: Description :
Scope :
Job # 98244
I Tilt-Up Wall Panel Design 45h
Analysis Data t
E 3,122.018.6 psi Sgross n=Es/Ec 9.29 Mcr = S * Fr 78,872.0 in# 288,000 in3
Fr = 273.86 psi Rho: Bar Reinf Pd 0.0214
Ht / Thk Ratio 16.00
Values for Mn Calculation ...
As:eff= (Pu:tot + AsFyyFy
a : (AsFy + Pu)/(.85 fc b) c=a/.85
Seismic
0.938 in
2.164 in
1.839 in
lgross 1.728.000 in4
lcracked 541.94 in4
I-eff (ACI methods only)
Phi: Capacity Reduction 0.00 in4
Mn = As:eff Fy (d - a/2) 362,000.80 in-#
0.900
Wind
0.833 in
1.632 in
1,728.00 in4
1.920 in
502.39 in4 0.00 in4
335,032.49 in# 0.900
I Additional Values t Loads used for analysis
Wall Weight
Wall Wt *Wall Seismic Factor 145.000 psf
43.500 psf
Wall Wt ' Parapet Seismic Factor 43.500 psf Applied Axial Load 34,361.59 28.443.29 #/n
Sewice Applied Axial Load Lateral Wall Weight 1,624.00 1,218.00 #/n
24,543.99 #/ft Sewice Wt @ Max Mom Total Lateral Loads 35,985.59 29,661.29#/fl
Total Service Axial Loads
1,160.00 #/ft
25,703.99 #/R
Factored Loads Seismic Wind
I ACI Factors (per ACI, applied internally to entered loads)
ACI 9-1 8 9-2 DL 1.400
ACI 9-1 8 9-2 LL 1.700 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4" Factor 1.400
ACI 9-3 Dead Load Factor
ACI 9-1 8 9-2 ST
0.900 UBC 1921.2.7 "0.9' Factor 0.900
.... seismic = ST' : 1.100
1.700 ACI 9-3 Short Term Factor 1.300
I
(c) 198597 ENERCALC ~ c:\enercalc\lotlOG.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouri Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201 Dsgnr: Date:
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Description :
Scope :
L Tilt-Up Wall Panel Design 46
LGeneral Information I
Description Line 8.2, Floor: 2""' Leg
Clear Height Parapet Height Thickness
Bar Size
Bar Spacing
Bar Depth
Max Defl. Ratio
Concrete Weight
16.000 n
0.000 n fc
FY 60,000.0 psi
4
8.000 in Phi
Min Vert Steel % 0.0020 0.900 Min Horiz Steel % 0.0012
11,000 in Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000 5.750 in Parapet Seismic Factor 0.3000
150.0
3,000.0 psi Seismic Zone
5 Width 12.000 in Base Fixity 0%
145.00 pcf Using: UBC Sec. 1914.0 method ... Exact. Non-Iterated
LL & ST Together
LLoads 1
Lateral Loads
Wind Load
Point Load Ibs ... eccentricity
Vertical Loads
Uniform LL Uniform DL 800.00 #/ft 960.00 #/ft
7.000 in
18.000 psf
... height n ... load type Seismic Concentric DL
Concentric LL
2,277.00 #In
1,920.00 #In
Lateral Load 58.00 #/n ... distance to top 12.500 n ... distance to bot n Seismic "111 Magnifier 1.000 ... load type Seismic Wind 'Y Magnifier 1.000
Wall Analysis I
Basic Defl wlo P-Deita
For Factored Load Stresses For Service Load Deflections Seismic - Wind
0.115 0.042 in Seismic Wind 0.092 0 035 in
Basic M wlo P-Delta 47,707.1 17,516.3 in-# 37,545.0 14,444.2 in# Moment Excess of Mcr 28,303.5 0.0 in# 11,091.0
Max. P-Delta Deflection 1.661 0.0 in# 1.727 in
Max P-Delta Moment 63,357.8 29,947.0 in-# 0.250 0.035 in 46,145.2 22,297.7 in#
Maximum Allow Vertical Bar Spacing 18,000 in
Maximum Allow Horizontal Bar Spacing 18,000 in Parapet Bar Spacing Req'd : SEISMIC 18,000 in
Parapet Bar Spacing Req'd : WIND 18,000 in
Wall Design OK
~~ . . . . . .
"
O.OOfl parapet, 8.00in thick with #5 bars at 11 .OOin on center, d= 5.75i1-1, fc = 3,000.0ps
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Maximum Iterated Moment : Mu 35,480.64 in#
Moment Capacity
Maximum Iterated Deflection
58.944.25 in-#
0.038 in
Deflection Limit 1.160 in
Mn Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @Top of Wall
Max Iterated Service Load Deflection Actual Deflection Ratio
Seismic 125,942.73 in-# 121,244.75 in-#
63,357.77 in-# 29,946.96 in-#
17.247.99 in-# 14,447.99 in-#
Wind
0.25 in
768 : 1 I Actual Reinforcing Percentage 0.0049
Allowable Max. Reinf. Percent = 0.5 * Rho Bal 0,0128
5,552 : 1
0.03 in
0.0049
0.0128
Actual Axial Stress : (Pw + Po ) / Ag
Allowable Axial Stress = 0.4 fm
70.11 psi
120.00 psi 70.11 psi
120.00 psi
_I___~ i
(C) 1983-97 ENERCALC c:\enercalcuotl06.ecw __ .. .. . "_ KW-0602755. V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Title : Lot 106 Redesign
Dsgnr: Dale: Descriplion :
scooe :
Job # 98244
Fax: (619) 485-6201 ." r- -
Tilt-Up Wall Panel Design 47 k
1 Analvsis Data i
E 3,122,018.6 psi
n = Es / Ec Fr = 9.29 273.86 psi
Ht I Thk Ratio 24.00
Values for Mn Calculation... As:eff= [Pu:tot + AsFy]/Fy
a : (AsFy + Pu)/(.85 PC b)
c=a/.85
lgross
lcracked
I-eff (ACI methods only)
Phi: Capacity Reduction
Mn = As:eff Fy (d - a/2)
Seismic
0.495 in
0.971 in
512.000 in4
1.142 in
103.62 in4
0.00 in4
139,936.36 in#
0.900
Sgross 128.000 in3
Mcr = S * Fr
Rho: Bar Reinf Pct
35.054.2 in#
0.0214
Wind
0.467 in
0.915 in
1.077 In
512.00 in4
99.68 in4
0.00 in4
0.900
134,716.39 in#
LAdditional Values 1 Loads used for analysis Factored Loads
Wall Weight
Wall Wt * Wall Seismic Factor 96.667 psf 29.000 psf Applied Axial Load 8,339.80 6,902.85 #/n
Wall Wt Parapet Seismic Factor 29.000 psf
Service Applied Axial Load
Lateral Wall Weight 1,082.67 812.00 #/R
5,957.00 #/n
Service Wt @ Max Mom
Total Lateral Loads 9,422.46 7.714.85#/R
Total Service Axial Loads 6,730.33 wn 773.33 #/n
Seismic Wind
ACI Factors (per ACI, applied internally to entered loads) -~~ I ACI 9-1 8 9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7 "1.4" Factor 1.400
ACI 9-1 8 9-2 LL
ACI 9-1 8 9-2 ST
1.700
1.700
ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7 "0.9" Factor 0,900
ACI 9-3 Short Term Factor .... seismic = ST *: 1,100
1.300
(c) 198597 ENERCALC c:\enercalc%l106.ecw KW-0602755, V5.0.2. 1-Jun-1997
16959 Bernard0 Center Drive #201
Firouzi Consulting Engineers, Inc Title : Lot 108 Redesign
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Dsgnr: Date: Description :
Scope :
Job # 98244
Tilt-Up Wall Panel Design 4% h L - .I
1 General Information
Description Line B.2, Floor: 8""' Leg
Clear Height 16.000 n fc 3,000.0 psi Seismic Zone
Parapet Height 0.000 n 4
Thickness 8.000 in FY 60,000.0 psi Phi
Min Vert Steel %
0.900
0.0020
Min Horiz Steel % Bar Size 5 12.000 in Base Fixity 0% 0.0012
Bar Spacing Width
14.000 in Bar Depth Parapet Weight Counteracts Midd Wall Seismic Factor 0.3000 3.625 in Max Defl. Ratio Parapet Seismic Factor 0.3000
150.0 Concrete Weight 145.00 pcf Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated LL & ST Together
I Loads I
Lateral Loads Vertical Loads
Wind Load 18.000 psf Uniform DL 800.00 #/ft
Point Load
Uniform LL 960.00 #/n
... height
... eccentricity
... load type Seismic Concentric DL 569.00 #/ft
480.00 #/ft
Ibs n 7.000 in
Lateral Load Concentric LL
14.50 #/n ... distance to top 12.500 n ... distance to bot n ... load type Seismic
Seismic "111 Magnifier
Wind "111 Magnifier
1,000
1.000 I
For Factored Load Stresses For Service Load Deflections Seismic Wind
Basic Defl wlo P-Deita 0.065 0.042 in
Basic M w/o P-Delta 26,663.8 17,516.3 in# 22,803.8
Moment Excess of Mcr 6,376.1 14,444.2 in#
Max. P-Deita Deflection 2.952
0.0 in# 0.0 0.0 in#
3.037 in Max P-Delta Moment 0.058
41,430.3
0.035 in
29,057.3 in# 27,285.2 18,480.8 in#
Maximum Allow Vertical Bar Spacing 18.000 in Parapet Bar Spacing Req'd : SEISMIC 18.000 in
Maximum Allow Horizontal Bar Spacing 18,000 in Parapet Bar Spacing Req'd : WIND 18.000 in
Wall Design OK
Seismic - Wind 0.056 0.035 in
0.OOfl parapet, 8.00in thick with #5 bars at 14.00in on center, d= 3.63in, fc = 3,OOO.Ops
Using: UBC Sec. 1914.0 method ... Exact, Non-Iterated
Factored Load Bending : Seismic Load Governs Service Load Deflection : Seismic Load Governs
Maximum Iterated Moment : Mu 35,480.64 in# Maximum Iterated Deflection
Moment Capacity
0.038 in
58,944.25 in-# Deflection Limit 1.160 in
Mn * Phi : Moment Capacity
Applied: Mu @ Mid-Span
Applied: Mu @Top of Wall
Max iterated Service Load Deflection
Actual Deflection Ratio
Seismic 60,223.77 in-#
41,430.35 in-#
17.247.99 in-#
3,399 : 1
0.06 in
I Actual Reinforcing Percentage
Allowable Max. Reinf. Percent = 0.5 * Rho Bai 0.0061
0.0128
Wind 58,064.49 in-#
29,057.31 in-#
14,447.99 in-#
5,552 : 1
0.03 in
0.0061
0.0128
Actual Axial Stress : (Pw + Po ) I Ag 37.32 psi
Allowable Axial Stress = 0.4 * fm 120.00 psi 37.32 psi
120.00 psi J
(c) 1983-97 ENERCALC - c:\enercalcYot106.ecw "0602755, V5.0.2.1 Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Fax: (619) 485-6201
Title : Lo1 106 Redesign Drgnr: Dale: Description :
Scope :
Job # 98244
..
Tilt-Up Wall Panel Design 49
[Analysis Data
~~~ I
E 3,122,018.6 psi n = Es / Ec 9.29
Fr = 273.86 psi Ht / Thk Ratio 24.00
Sgross
Mcr = S Fr
Rho: Bar Reinf Pct 0.0214
128.000 in3
35,054.2 in#
Values for Mn Calculation ... As:eff= [Pu:tot + AsFyYFy
a : (AsFy + Pu)/(.85 PC b) c = a / .85
lgross
lcracked
I-eff (ACI methods only)
Phi: Capacity Reduction Mn = As:eff Fy (d - a/2)
Seismic 0.349 in
0.685 in 0.806 in 512.000 in4
27.88 in4 0.00 in4
0.900
66,915.30 in#
I Additional Values
Wind 0.334 in
0.655 in
512.00 in4
0.770 in
27.10 in4
0.00 in4
64.516.10 in#
0.900
h
k I Loads used for analysis
~~ ~~~
Wall Weight 96.667 psf
Wall Wt * Wail Seismic Factor 29.000 psf
Seismic
Applied Axial Load 3,932.60 3,273.45 #/ft
Wind
Wall Wt * Parapet Seismic Factor 29,000 psf Lateral Wall Weight 1.082.67
Service Applied Awial Load 812.00 #/ft
Service Wt @ Max Mom
Total Service Axial Loads 3,582.33 #/ft
Factored Loads
2,809.00 #/ft Total Lateral Loads 5,015.27 4,085.45#/ft 773.33 #/n
1 ACI Factors (per ACI, applied internally to entered loads)
ACI 9-1 8 9-2 DL 1.400 ACI 9-2 Group Factor
1.700 0.750 UBC 1921.2.7"1.4" Factor 1.400
ACI 9-3 Dead Load Factor
ACI 9-1 & 9-2 ST 0.900 UBC 1921.2.7"O.Q Factor 0.900 1.700 ACI 9-3 Short Term Factor 1.300 .... seismic = ST' : 1,100
I
ACI 9-1 a 9-2 LL
(c) 1983-97 ENERCALC c:\enercalcUoIl06~ecw KW-0602755, V5.0.2. 1-Jun-1997
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 92128
16959 Bernard0 Center Drive, Sub 201
Phone (619) 4854227, Fax (019) 4856201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov ‘98 Page IEQ
FOUNDATION DESlGN
Continuous Footings
Floor DL = 65 PSF
Reduced Floor LL = 50 PSF
Weight of Concrete = 145 PCF
Alona Line A
Wall Thickness =
Wall Height =
Roof Trib. Width =
Floor Trib. Width =
Alona Line G
Wall Thickness =
Wall Height =
Roof Trib. Width =
Floor Trib. Width =
Alona Lines 1 8 6
Wall Thickness =
Wall Height =
Roof Trib. Width =
Floor Trib. Width =
8
32
24
12
8
32
30
30
8
32
5
3.5
Roof DL = 15 PSF
Reduced Roof LL = 12 PSF
IN
FT
FT wDL= 4233 PLF
FT wLL= 888 PLF
IN
FT
FT wDL= 5493 PLF
FT wLL = 1500 PLF
IN
FT
FT wDL= 3396 PLF
FT wLL= 175 PLF
Spread Footings
D B 4.Y5.5. Noor Onlv Rf + Nr
1.5 B B 4BB Line C LineC DB 1.Y2.5 DB 2/3 D 8 4/5
Floor Area (ft’)
100 I 80 80 100 80 80 80 Floor LL (psf)
65 65 I 65 I 65 65 65 65 Floor DL (psf)
1144 1 1144 1 824 683 683 750 624
R = .08(A - 150) 38 48 43 80 80 38 43 R 23.1(1 + D/L) 42 42 42 42 38 38 42
and R < 40 (I-story)
and R < 60 (others)
R used
Reduced Floor LL 50 38 I 40 I I I I I 48
38
50
38
50 60 80 50
40 40 38
Roof Area (ft’)
12 12 0 12 0 0 0 Roof LL (psf)
15 15 0 15 0 0 0 Roof DL (psf)
2288 2288 0 1989 0 0 0
PDL (kips) 40.6 48.8 44.4 74.2 74.4 108.7 74.9
PLL (kips) 31.0 36.0 33.9 - 57.7 L 68.6 96.1 58.4
Total Load (kips) 71.5 84.8 78.3 132.0 143.0 204.8 133.3
- -
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego. California 92128
16959 Bernard0 Center Drive, Suite 201
Phone (619) 485-6227, Fax (619) 485-6201
Project: Lot 106 Redesign
Job #: 98244 Bv:
Date: Nov ‘98
FOUNDATION DESIGN, continued
Spread Footings, continued
Lines E a F
Floor Area (fl’)
80 Floor LL (psf)
65 Floor DL (psf)
520
R = .08(A - 150) 30 -1 2 R C 23.1(1 + DL)
-12
42
-12
#DIV/O!
-12
#DIV/O! #D!V/O! #DIV/O!
-12 -12
#DIV/O! #DIV/O!
and R c 40 (1-stow)
and R c 60 (others)
R used
Reduced Floor LL
Roof Area (ft’)
Roof DL (psf)
Roof LL (psf)
PDL (kips)
PLL (kips)
Total Load (kips)
30 I 1 1 1 1 1 56 0 0 0 0 0 0
0
0
0
33.8 0.0 0.0 0.0 0.0 0.0 0.0
- 29.1 - 0.0 - 0.0 - 0.0 - 0.0 - 0.0 0.0
62.9 0.0 0.0 0.0 0.0 0.0 0.0
-
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Title : Lot 106 Redesign Drgnr: Dats: Description :
Scone !
Job # 98244
Fax: (619) 485-6201 __.p_.
I General Footing Analysis & Design cy7 L ~ - w-
LGeneral Information - I
Description Continuous Footings
Along Lines A, 1 & 6
Allowable Soil Bearing 2,000.0 psf
Short Term Increase
Dimensions ...
Base Pedistal Height 0.000 in
1.330 in Width along X-X Axis 3.500 n
Length along Y-Y Axis 1.000 fl
Seismic Zone 4 Footing Thickness 18.00 in
Overburden Weight
Live & Short Term Combined
9.00 in
12.00 in
fc
Concrete Weight
0.00 psf Coi Dim. Along X-X Axis
Coi Dim. Along Y-Y Axis
FY
3,000.0 psi
145.00 pcf
60,000.0 psi Min Steel 0.0014
Rebar Cover 3.00 in I Loads "" __- ~ t Applied Vertical Load ...
Dead Load 4.230 k
Live Load 0.890 k
Short Term Load k
... ecc along X-X Axis 0.000 in
... ecc along Y-Y Axis 0.000 in
Creates Rotation about Y-Y Axis Creates Rotation about X-X Axis
Applied Moments ... (pressures @ left & right) (pressures @top & bot)
Dead Load
Live Load
Short Term
k-n k-ft
k-n k-n
k-n k-n
Creates Rotation about Y-Y Axis Creates Rotation about X-X Axis
(pressures @ lefl & right) (pressures @top & bot) Applied Shears...
Dead Load
Live Load
Short Term
k k
k k
k k
." - ." - "
Footing Design OK
3.50 fl X 1 .OO fl Footing, 18.0 in Thick, w19.00 x 12.00 in column 0.0 in high
DL+LL DL+LL+ST
Max Soil Pressure 1,680.4 1,680.4 psf Max Mu/Phi 2.229 k-ft
0.252 in2
"X Ecc, of Resultant 0.000 in 0.000 in Vu : 1-Way
"Y' Ecc, of Resultant 0.000 in 0.000 in Vu ~ 2-Way
2.037 93.113 psi
2.083 186.226 psi
X-X Min. Stability Ratio ggg,ooo:1 1.500 :I
Y-Y Min. Stability Ratio ggg.000:1
&&I Allowable
Allowable 2,000.0 2,660.0 psf Required Steel Area
(C) 1983-97 ENERCALC __ ~" c:knercabYoll06.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227 Scope :
Fax: (619) 485-6201
Dsgnr: Date: Description :
- L General Footing Analysis & Design "
53
1 Footing Design 1
Shear Forces m-lm Vn * Phi
Two-way Shear 2.08 2.01 1.07 psi 186.23 psi
One-way Shears ...
Vu/Phi @ Left 2.04 1.97 1.05
VulPhi @ Right 2.04 1.97 1.05
93.11 psi
VulPhi @ Top 0.00 0.00
93.11 psi
0.00
VulPhi @ Bottom 0.00 0.00 0 00 93.11 psi
93.11 psi
Moments
Mu/Phi Cil Left 2.23 2.15 1.14 k-ft
" Ru - As Rea'd 9.9 psi 0.25 in2
Mu/Phi 6 Right 2.23 2.15 1.14 9.9
Mu/Phi @ Top
0.25
0.00 0.00 0.00 0.0
Mu/Phi @ Bottom
0.02
0.00 0.00 0.00 0.0 0.02
I Soil Pressure Summary
Sewice Load Soil Pressures Left Right
DL + LL 1,680.36
TOP Bottom
1.680.36
DL+LL+ST 1,680.36
1,680.36 1,680.36 psf
1,680.36 1,680.36 1,680.36 psf
ACI Eq. 9-1 2,428.79 2.428.79 2,428.79
ACI Eq. 9-2
2,428.79 psf
ACI Eq. 9-3
2,352.50
1,283.46
2,352.50 2,352.50 2,352.50 psf
1.283.46 1.283.46 1,283.46 psf
Factored Load Soil Pressures
-~ I ACI Factors (per ACI, applied internally to entered loads) 1 ACI 9-1 8 9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4 Factor 1.400
ACI 9-1 8 9-2 LL
ACI 9-1 8 9-2 ST
1.700 ACI 9-3 Dead Load Factor
1.700
1.400 UBC 1921.2.7 "0.9" Factor 0.900
ACi 9-3 Short Term Factor 1.400
.... seismic = ST * : 1.100
Firouzi Consulting Engineers, Inc Tltle : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Dsgnr: Date: Description :
scope :
L ._._____
General Footing Analysis & Design 5t
[General Information ~ ~ 1
Description Continuous Footings
Along Line G
Allowable Soil Bearing 2,000.0 psf
Short Term Increase 1.330 in Width along X-X Axis 4.500 n
Base Pedistal Height 0.000 in Length along Y-Y Axis 1.000 ft
Seismic Zone 4 Footing Thickness 18.00 in
Overburden Weight 0.00 psf
Live 8 Short Term Combined
12.00 in
12.00 in
Dimensions...
Col Dim. Along X-X Axis
Col Dim. Along Y-Y Axis
fc 3,000.0 psi
FY Concrete Weight
60,000.0 psi Min Steel
145.00 pcf Rebar Cover
0.0014
3.00 in
[Loads L
Applied Vertical Load ...
Dead Load 5.500 k ... ecc along X-X Axis 0.000 in
Short Term Load
Live Load 1.500 k ... ecc along Y-Y Axis 0.000 in
k
Creates Rotation about Y-Y Axis Creates Rotation about X-X Axis
Applied Moments ... (pressures @ left 8 right) (pressures @top 8 bot)
Dead Load k-fl k-ft
Live Load
Short Term
k-ft k-n
k-ft k-ft
Creates Rotation about Y-Y Axis Creates Rotation about X-X Axis
Applied Shears ... (pressures @ lefl8 right) (pressures @top & bot)
F-
Dead Load k
Live Load
Short Term
k
k k
k k
Summary ~ ~.__
Footing Design OK
4.50 ft x 1.00 ft Footing, 18.0 in Thick, w112.00 x 12.00 in column 0.0 in high
Max Soil Pressure 1,773.1 1,773.1 psf Max Mu/Phi 3.874 k-ft
DL+LL DL+LL+ST Actual Allowable
Allowable 2,000.0 2,660.0 psf Required Steel Area 0.252 in2
"x' Ecc, of Resultant 0.000 in 0.000 in Vu : I-Way
"Y' Ecc, of Resultant 6.840
0.000 in
93.113 psi
0.000 in Vu ~ 2-Way 3.013 186.226 psi
X-X Min. Stability Ratio ggg.o00:1
Y-Y Min. Stability Ratio ggg.000 :I 1.500 : 1
(c) 1983-97 ENERCALC c:!enercalcUollOG.ecw " KW-0602755, V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Title : Lot 106 Redesign Dsgnr: Description :
Scope :
Job # 98244
Date:
___. Footino Desion , - I
Shear Forces
Two-way Shear 3.01 2.88 1.46 psi 186.23 psi
Vn Phi
One-way Shears ...
VulPhi @ Len
VulPhi @ Right
6.84
6.84
6.54 3.31 93.11 psi
VulPhi @ Top 0.00
6.54 3.31 93.11 psi
VulPhi @ Bottom 0.00
MulPhi @ Left 3.87 3.70 1.87 k-ft
As Rea'd
MulPhi @ Right 3.87 3.70 1.87 17.2 psi 0.25 in2
MulPhi @ Top
17.2
0.00
0.25
MulPhi @ Bottom
0.00 0.00 0.0
0.00 0.00 0.00 0.0
0.02
0.02
0.00 0.00 93.11 psi 0.00 0.00 93.11 psi
Moments &!&!- Ru -
- ~ ~~ ~~ [soil Pressure Summary
Service Load Soil Pressures Left Right
DL + LL 1.773.06 TOP Bottom 1,773.06
DL+LL+ST 1,773.06 1,773.06 1,773.06 1,773.06 psf
1,773.06 1,773.06 psf
ACI Eq. 9-1 2,582.28 2,582.28 2,582.28 2,582.28 psf
ACI Eq. 9-2 2,482.28
ACI Eq. 9-3
2,482.28 2,482.28 2,482.28 psf
1,295.75 1,295.75 1,295.75 1,295.75 psf
1
Factored Load Soil Pressures
~- I ACI Factors (per ACI. applied internally to entered loads) b L
ACI 9-1 8 9-2 DL
ACI 9-1 8 9-2 LL
1.400
1.700
ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4" Factor 1.400
ACI 9-1 8 9-2 ST
ACI 9-3 Dead Load Factor 1.400 UBC 1921.2.7"O.Q Factor 0.900
1.700 ACI 9-3 Short Term Factor 1.400 .... seismic = ST' ; 1.100
I
(C) 1983-97 ENERCALC c:\enercalcWoll06.ecw KW-0602755. V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Fax: 1619) 485-6201
Title : Lot 106 Redesign Dsgnr: Date: Dercriptlon :
Scope :
Job # 98244
..
1 General Information
Description Total Load < 85 kips
Dead Load 48.800 k
Live Load 36.000 k
Short Term Load 0.000
Seismic Zone 4 Overburden Weight
Concrete Weight
LL 8 ST Act Seperately Load Duration Factor 1.330 Column Dimension 8.00 in
0.000 psf
145.00 pcf
Thickness
Footing Dimension
24.00 in
7.500 fl
#of Bars
Bar Size
6
6 Rebar Cover
fc
3.250
FY
3,000.0 psi
Allowable Soil Bearing 2,000.00 psf 60,000.0 psi
1 General I
Rebar Requirement Actual Rebar"d depth used 20.375 in
2OO/Fy As to USE per foot of Width 0.342 in2
As Req'd by Analysis 0.0006 in2 Min Allow % Reinf 0.0014 2.567 in2
Min. Reinf % to Req'd
0.0033 Total As Req'd
0.0014 % ___ ~ ""
Footing OK
7.50ft square x 24.0in thick with 6- #6 bars
Max. Static Soil Pressure
Allow Static Soil Pressure
1,797.56 psf Actual 1-Way Shear 22.40 psi
Allow Short Term Soil Pressure 2,660.00 psf Max. Short Term Soil Pressure 1,157.56 psf Actual 2-Way Shear
Allowable 2-Way Shear 69.80 psi
219.09 psi
2,000.00 psf Allow. 1-Way Shear 109.54 psi
Mu I Phi : Actual
Mn : Capacity 17.57 k-ft Alternate Rebar Selections ... . 35.25 K-ft
(c) 1983-97 ENERCALC - ~ ~ c:\enercalc~oll06.ecw KW-0602755, V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Fax: (619) 485-6201
Title : Lot 106 Redesign Job # 98244 Dsgnr: Date: Description :
Scope :
I Sauare Footing Desian K7 c
Description Total Load > 85 kips
Total Load c 143 kips
Dead Load 74.400 k Footing Dimension
Live Load
10.000 ft
Short Term Load 0.000 # of Bars
Thickness 24.00 in
7
Seismic Zone 4 Bar Size 7 Overburden Weight 0.000 psf Rebar Cover 3.250
Concrete Weight 145.00 pcf fc 3,000.0 psi
LL & ST Act Seperately FY 60,000.0 psi Load Duration Factor 1.330 Allowable Soil Bearing 2,000.00 psf Column Dimension 8.00 in
68.600 k
[ General - 1
Rebar Requirement Actual Rebar "d depth used 20.313 in As to USE per foot of Width 2OO/Fy 0.0033 Total As Req'd 3.779 in2 0.378 in2
As Req'd by Analysis
Min. Reinf % to Req'd
0.0012 in2 Min Allow % Reinf 0.0016 %
0.0014
- Footing OK
10.00fl square x 24.0in thick with 7- #7 ban
Max. Static Soil Pressure
Allow Static Soil Pressure
1,720.00 psf Actual 1-Way Shear 37.52 psi
109.54 psi
Max. Short Term Soil Pressure 1,034.00 psf Allow Short Term Soil Pressure 2,660.00 psf Actual 2-Way Shear 126.23 psi Allowable &Way Shear 219.09 Dsi
2,000.00 psf Allow. 1-Way Shear
Mu / Phi : Actual
Mn : Capacity
31.62 k-fl
41.79 k-ft
Alternate Rebar Selections ...
19 #4's 13 #5s 9 #6's 7 #7'S 5 #0s 4 #9's 3 #lo's
(C) 1983-97 ENERCALC ~ ~- c:\enercalcUotl06.ecw "0602755. V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Fax: (619) 485-6201
Title : Lot 106 Redesign Dsgnr: Date: Description :
Scope :
Job # 98244
I General Information
Description Total Load > 143 kips
Total Load < 205 kips
Dead Load
Live Load
Footing Dimension
Thickness
12.000 R
Short Term Load 0.000 # of Bars 24.00 in 12
Seismic Zone 4 Bar Size 7
Overburden Weight 0.000 psf Rebar Cover 3.250
Concrete Weight 145.00 pcf fc 3,000.0 psi
LL 8 ST Act Seperately FY 60,000.0 psi
Load Duration Factor 1.330 Allowable Soil Bearing 2,000.00 psf Column Dimension 8.00 in
108.700 k
96.100 k
I General "___ I
Rebar Requirement Actual Rebar "d depth used
2OO/Fy
20.313 in As to USE per foot of Width 0.557 in2
0.0033 Total As Req'd
As Req'd by Analysis 6.688 in2 0.0017 in2 Min. Reinf % to Rea'd 0.0023 %
Min Allow% Reinf 0.0014
~~ ~~
Footing OK
12.00ft square x 24.0in thick with 12- #7 bars
Max. Static Soil Pressure
Allow Static Soil Pressure 1,712.22 psf
2,000.00 psf Actual 1-Way Shear Allow. 1-Way Shear 49.82 psi
109.54 psi
Max. Short Term Soil Pressure 1,044.86 psf
Allow Short Term Soil Pressure 2,660.00 psf Allowable 2-Way Shear Actual 2-Way Shear
219.09 psi 183.88 psi
Mu / Phi : Actual
Mn : Capacity
46.33 k-fl
59.17 k-fl
Alternate Rebar Selections ...
34 #4's 22 #5's 16 #6's
12 #7's 9 #8's 7 #9s 6 #lo's
(c) 198597 ENERCALC __ "" ~~~ c:knercalc\io1106.ecw KW-0602755, V5.0.2. 1-Jun-1997
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 92128
16959 Bernardo Center Drive. sune 201
Phone (619) 485-6227. Fax (619) 485.6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page Z?
LATERAL ANALYSIS
Seismic Coefficient
2 = 0.4 C= 2.75
I = 1.0 R, = 6
V = 0.183 x Weight
Transverse Direction
Tributary Roof Dead Loads
Roof DL = (I 5 ps9(136 fl) -
Wall DL = (97 psf)(9 fl)(2 walls)
- 2040 PLF - 1746
W, = 3786 PLF
-
w; = (W, X 168') - - 984.4 KIPS
DL of end wall = 2(97 psf)(l36 fl)(9 ft) - - 237.5 KIPS
Total DL Trib. to Roof = 1221.8 KIPS
Tributary Floor Dead Loads
2nd Floor DL = (70 PW36 fl) - - 9520 PLF
Wall DL = 2@7 PSW fl) + (145 psf)(8 ft)) - - 3872
W3 = 13392 PLF
W2) = (W3 x 260') - - 3481.9 KIPS
DL of end wall = Z(136 ft)((97 psf)(8 fl) + (145 psf)(8 fl)) = 526.6
Total DL Trib. to 2nd Floor = 4008.5 KIPS
Seismic Table
Basic Shear, V = ,183 x X(wJ = 957.2 KIPS
story hx Fpx I wpx Fx I wx Fx wxhx wx
R 32 1221.8
957.2 103234 5230.3
0
0.183 0.148 594.6 641 36
1
4008.5
0.297 0.297 362.5
16 2
39098
Diaphragm Loads
w1,2,3 = (15 psf)(l36 fl) + (97 psf)(9 f1)(2 walls) = 3786 plf
w, = (90 psf)(60') + (65 psf)(76') + 2[(97 psf)(8) + (145 psf)(8)] = 14212 plf
we = (65 psf)(l36 fl) + 2[(97 psf)(8 ft) + (145 psf)(8 ft)] = 12712 plf
W5 = (45 psf)(20') + (62.5 psf)(20') + (65 psf)(ll6') + 2((97 psf)(8') + (145 psf)(8')] 13562 Plf
FlROUZl
CONSULTING
ENGINEERS, INC.
16959 Bernard0 Center Drive, Suite 201
San Diego. California 92128
Phone (619) 485-6227, Fax (619) 485.6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page 60
LATERAL ANALYSIS, continued
Lonoitudinal Direction
Tributary Roof Dead Loads
Roof DL = (15 psf)(260 fl) - 3900 PLF
Wall DL = (97 psf)(9 fl)(2 walls) - - 1748
-
WI = 5646 PLF
W,' = (Wl x 136') - - 767.9 KIPS
DL of 2 end walls = (97 psf)(260 f1)(9 fl) - - 201.8 KIPS
Total DL Trib. to Roof = 969.6 KIPS
Tributary Floor Dead Loads
2nd Floor DL = (70 ~sO(260 fll - - 18200 PLF
Wall DL = 2[(97 ps&3 it) +(I45 psf)(8 fl)] - - 3872
W,= 22072 PLF
WZ' = (W, x 136') - - 3001.8 KIPS
DL of 2 end walls = ((97 psf)(8 fl) + (145 psf)(8 fl))(260 fl) =
Total DL Trib. to 2nd Floor 3505.2 KIPS
503.4
Seismic Table
Basic Shear, V = .I 83 x X(wJ = 818.9 KIPS
story
R
hx FX wxhx WX
1
2
Fpx I wpx Fx I Wx
32 969.6
818.9 87110 4474.8
0
0.183 0.150 527.2 56082 3505.2
0.301
16
0.301 291.7 31 028
Diaphragm Loads
w, = (15 psf)(260 ft) + (97 psf)(9 fl)(2 walls) = 5646 plf
Wa = (70 psf)(260 fl) + 2((97 psf)(8 ft) + (145 psf)(8 fl)) = 22072 plf
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego. Califomla 92128
16959 Bemardo Center Drive, Suite 201
Phonc (619) 4858227, Fax (819) 4955201
Project: Lot 108 Redesign
Job #: 98244 By:
Date: Nov '98 Page@/
DIAPHRAGMS
FlROUZl
CONSULTING
ENGINEERS, INC.
16959 Bemardo Center Drtva, Suite 201
San Dkgo. Califwnh 92128
Phons (61 9) 4858221. Flu (819) 4656201
Project: Lot 108 Redesign
Job #: 98244 By:
Date: Nov '98 Page a2
DIAPHRAGMS
I
I
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Fax: (619) 485-6201
Title : Lot 106 Redesign Dsgnr: Date: Description :
scope :
Job # 90244
L Horizontal Plywood Diaphragm 61
[ General Information
Description Roof
I
Diaphragm 1
North-South Length 136.00 fl
Ease-West Length
Diaphrgm Weight
130.00 fl Seismic Factor 0.2970
Nort-South Chord 136.00 fl Diaphragm is Blocked
East-West Chord 130.00 fl Blockino Direction North-South
0.00 psf
-
Boundary Loads Acting North & South t #1 3,786.00 #/fl from 0.000fl to 0.000 ft
#2
#3
#4
#/fl from o.ooon to
#lfl from o.oooft to
#lfl from o.oooft to 0.000 fl
0.000 ft
0.000 ft
1 Boundary Loads Acting East & West 1 #1 #/ft o.ooon to 0.000 fl
#2
from
from
#3
0.000R to 0.000 fl
#4 wft O.OOOR to 0.000 n from
0.000 fl
#In
#/ft from o.ooon to
Shear Zone
Spacing Value Distance
in
At North Wall 2x 112
2nd zone 2x
Structural I
112“
3rd zone 2x 112” Structural I
Structural I
Center zone 2x 112”
3rd zone 2x 112”
Structural I
2nd zone 2x
Structural I
112“
At South Wall 2x 112
Structural I
Structural I
1 Od
in
2,3,12
#/fl fl
10d
730.0
2.5,3.12
0.00
1 Od
640.0
4,6,12
0.00
425.0
1 Od
0.00
6,6,12
1 Od
320.0
4,6,12 425.0
1 Od 2.5,3,12
0.00
640.0
1 Od 2.3.12 730.0
0.00
0.00
Design Data 8 Nailing Requiremen
Framing
At West Wall 2x
2nd zone
3rd zone
2x
2x
3rd zone
Center zone 2x
2x
2nd zone 2x
At East Wall 2x
Thickness
in
1 I2
112”
112”
112”
112”
112”
1P
Grade
Structural I
Structural I
Structural I
Structural I
Structural I
Structural I
Structural I
Nail Size
10d
1Od
10d
1Od
1 Od
1 Od
1 Od
Spacing
in
2,3,12
2.5,3,12
6,6,12
4,6,12
2.5,3,12
4,6,12
2,3,12
Shear
Value
#lfl
640.0
730.0
425.0
320.0
425.0
640.0
730.0
Distance
Zone
fl
0.00
14.04
26.52
26.52
14.04
0.00 I I .~ __ LShear 8 Chord Forces
__~___
Diaphragm Shears ... North - South Total Shear 0.Olbs 73,088.71bs
East
73,088.7 Ibs
Shear per Foot o.oo#/ft o.oo#/n 537.42#1fl 537.42 #In
@ 114 * Length 13,029.41bs
@ 112 * Length
0.Olbs
@ 314 * Length
17,466.1 Ibs
13,169.1 Ibs 0.Olbs
0.Olbs
- 0.Olbs
West
Chord Forces ...
Length / Width Ratio 1.046
Firouri Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201 Drgnr:
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Date: Description :
Scope :
Horizontal Plywood Diaphragm LZ h
LGeneral Information
Description Roof I
Diaphragm 2
North-South Length 136.00 n Diaphrgm Weight 0.00 psf
Ease-West Length 62.50 n Seismic Factor 0.2970
Nort-South Chord 136.00 n Diaphragm is Blocked
East-West Chord 62.50 fl Blocking Direction North-South I Boundary Loads Acting North &South 1 #1
#2
3.786.00 #lft from o.ooon to o.ooo n
from o.ooon to 0.000 ft #In
#3
#4
#If! from
#/ft from
o.ooon to o.ooo n o.ooon to o.ooo n I Boundary Loads Acting East & West 1
#1 #lft from o.ooon to 0.000 ft
#2
#4
#3
#lft from o.ooon to 0.000 n
#lft from
from 0.000ft to 0.000 ft #In
o.ooon to 0.000 ft
I Framing Thickness in
Grade
At North Wall 2x
2nd zone 2x
1 /2
112
Structural I
3rd zone
Structural I
2x
Center zone 2x
112" Structural I
3rd zone
In" Structural I
2x
2nd zone
1 12
2x
Structural I
112"
At South Wall 2x 1 /2
Structural I
Structural I
Nail Size
1 Od
1 Od
1 Od
10d
1 Od
1 Od
1 Od
Spacing
in
2,3,12
2.5,3.12
4.6.12
6,6,12
2.5.3,12
4,6,12
2.3.12
Shear
Value
#lft
730.0
640.0
425.0
320.0
425.0
640.0
730.0
Distance
Zone
ft
0.00
0.00
0.00
0.00
0.00
0.00
Design Data & Nailing Requiremen
Shear 7one
1
Framing Thickness Grade Nail Size Spacing Value Distance
in
At West Wall 2x 1 I2 Structural I
2nd zone 2x
1 Od 2,3,12
112 Structural i 1 Od 2.5,3,12
730.0 0.00
3rd zone 2x 1 12
640.0 0.00
Structural I
Centerzone 2x
10d
112"
4,6.12 425.0
Structural I 10d
0.00
6,6,12
3rd zone 2x 1 /2 Structural I 1 Od 4,6,12 425.0
320.0
0.00
At East Wall
2nd zone 2x 112
2x 112
Structural I 1 Od 2.5,3,12
Structural I 1 Od 2,3,12 730.0
640.0 0.00
0.00
in #Ift n
I "" I Shear 8 Chord Forces
Diaphragm Shears ... - North
Total Shear O.Olbs 0.Olbs 35.138.8ibs 35,138.8 ibs
Shear per Foot o.oo#/n o.oo#/n z58.37#1n 250.37 #In
@ 114 Length 3,011.61bs
@ 1/2 * Length
0.Oibs
@ 3/4 * Length
4,031.1 Ibs
3,043.9ibs O.Olbs
0.Olbs
- East
Chord Forces ...
Length I Width Ratio 2.176
(c) 1983-97 ENERCALC c:\enercaicYotl06.ecw KW-0602755, V5.0.2. 1-Jun-1597
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Fax: (619) 485-6201
Phone: (619) 485-6227
Title : Lot 106 Redesign Drgnr: Dale: Descrlptlon :
Scope :
Job # 98244
L Horizontal Plywood Diaphragm 63 I
LGeneral Information
Description Roof 1
Diaphragm 3
North-South Length 136.00 n
Ease-West Length
Diaphrgm Weight
Nod-South Chord 136.00 n Diaphragm is Blocked
East-West Chord 67.50 n Blockina Direction North-South
67.50 n Seismic Factor 0.2970
0.00 psf
- L Boundary Loads Acting North & South t #1 3,786.00 #/ft from o.ooon to 0.000 n
#2
#3
#4
#/n from #/n from
o.ooon to o.ooon to 0.000 n #/n from o.ooon to 0.000 n
0.000 ft
I Boundary Loads Acting East & West 1 #1 wn from o.ooon to 0.000 n
#2
#3
#4
#In from o.ooon to 0.000 n #In wn o.ooon to 0.000 n from
from o.ooon to 0.000 n
Design Data 8 Nailing Requiremen
Thickness Grade
in
At North Wall 2x 112”
2nd zone
Structural I
3rd zone
2x 112” Structural I
2x 1 12” Structural I
Center zone 2x
3rd zone
1P
2x
Structural I
2nd zone
112” Structural I
2x
At South Wall 2x
112”
1 12”
Structural I
Structural I
-
Nail Size
1 Od
1 Od
1 Od
1 Od
1 Od
10d
1 Od
Spacing
in
2.3,12
2.5,3,12
6,6,12
4,6,12
2.5,3,12
4,6,12
2,3.12
Value
Shear
Distance
Zone
#/ft n
730.0
640.0
0.00
425.0 0.00
0.00
320.0
425.0
640.0
0.00
730.0
0.00
0.00
Framing
At West Wall 2x
2nd zone
3rd zone
2x
2x
3rd zone
Center zone 2x
2x
2nd zone 2x
At East Wall 2x
Thickness
in
1 12”
1 12”
1W
112”
112”
112”
1 12”
Grade
Structural I
Structural I
Structural I
Structural I
Structural I
Structural I
Structural I
Nail Size
1 Od
1 Od
10d
1 Od
10d
1 Od
1 Od
Spacing
in
2,3,12
2.5,3,12
6,6.12
4,6,12
2.5,3,12
4,6,12
2.3,12
Shear
Value #In
730.0
640.0
425.0
320.0
425.0
640.0
730.0
Distance
Zone
0.00
0.00
0.00
0.00
0.00
0.00
n
I
LShear 8 Chord Forces
- ~. t Diaphragm Shears ... - North - yy@ South
Total Shear O.Olbs 37,949.91bs 37,949.9 Ibs
Shear per Foot o.oo#/n o.oo#/n 279.04#/n 279.04 #/n
0.Olbs
m
Chord Forces...
@ 114 * Length
@ 112 Length
3,512.71bs
@ 314 Length 3,550.41bs
4,708.91bs
Length I Width Ratio 2.015
0.Olbs
0.Olbs
O.Olbs
(c) 1983-97 ENERCALC c:!enercalcUotl06.ecw W-0602755, V5.0.2, 1-Jun-1597
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign
16959 Bemardo Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Job # 98244 Dsgnr: Date: Description :
Scope : Fax: (619) 485-6201 L Horizontal Plywood Diaphragm 64
I General Information
Description Floor I
Diaphragm 4
North-South Length 136.00 n Diaphrgm Weight
Ease-West Length 130.00 n Seismic Factor 0.1830
Nort-South Chord 136.00 n Diaphragm is Blocked
East-West Chord 130.00 n Blocking Direction North-South
0.00 psf
1 Boundary Loads Acting North 8 South I #1 5,000.oo #In
#2 5,000.oo #In from o.ooon to
from
#3 4,212.00 wn
#4 #In from
from
0.000 n o.ooon to 0.000 n o.ooon to 0.000 n o.ooon to 0.000 n
Boundary Loads Acting East & West I #1 wn from o.ooon to 0.000 n
#2
#3
wn wn
~ ~~~ ~
from o.ooon to
from o.ooon to
0.000 n
0.000 n
#4 #In from o.ooon to 0.000 n
Shear Zone
At North Wall
2nd zone
3rd zone
3rd zone
2nd zone
At South Wall
Center zone
in
2x
2x
112"
112"
Structural II
2x 112"
Structural II
2x
Structural II
2x
1/2" Structural II
1/2"
2x 1 R"
Structural II
2x
Structural II
1R" Structural II
Design Data 8 Nailing Requiremen
1 Od
in
1 Od
2,3,12
1 Od
2.5,3,12
1 Od
4,612
1 Od
6,6.12
1 Od
4.6,12
2.5,3,12
1 Od 2,3,12
Framing
At West Wail 2x
2nd zone
3rd zone 2x
2x
3rd zone
Center zone 2x
2x
2nd zone
At East Wall
2x
2x
Thickness
in
112"
1R"
1/2"
1 R"
1 R"
112"
112"
Grade
Structural II
Structural II
Structural II
Structural II
Structural II
Structural II
Structural II
Nail Size
1 Od
1 Od
1 Od
1 Od
1Od
1 Od
1 Od
Spacing
in
2,3,12
2.5,3,12
6,6,12
4.6,12
2.5,3,12
4,6,12
2,3,12
655.0
575.0
385.0
290.0
385.0
575.0
655.0
#In
Shear
Value
#In
655.0
575.0
385.0
290.0
385.0
575.0
655.0
n
0.00
0.00
0.00
0.00
0.00
0.00
Zone
Distance
35.36
45.24
49.92
49.92
45.24
35.36
n
I I I Shear 8 Chord Forces
Diaphragm Shears...
Total Shear O.0lbs 169051.7ibs 169051.7 Ibs
Shear per Foot o.oo#/n o.oo#/n 1,243.03#Ift 1,243.03 #In
@ 114 * Length
@ 1R Length
@ 314 Length
South
0.Olbs - - East
Chord Forces. ..
30,136.61bs
40,398.41bs
O.Olbs
0.Olbs
30,459.71bs O.Olbs
Length I Width Ratio 1.046
(c) 198597 ENERCALC c:!enercalcVotl06.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Title : Lot 106 Redesign
Drgnr: Date: Dercrlption :
Job # 98244
scnne !
Fax: (619) 4854201 "_r_.
Horizontal Plywood Diaphragm LS h L - Y-
LGeneral Information I
Description Floor
Diaphragm 5
North-South Length 136.00 fl Diaphrgm Weight
Ease-West Length 62.50 fl Seismic Factor
Nort-South Chord 136.00 n Diaphragm is Blocked
East-West Chord 62.50 fl Blockina Direction North-South
0.00 psf
0.1830
- 1 Boundary Loads Acting North 8 South 1 #1 5,000.00 #/fl from o.ooon to 0.000 n
#2 5,ooo.oo #In from O.OOOfl to
#3 3,562.00 #lfl from
0.000 n
#4 wfl from 0.000fl to
o.ooon to 0.000 n
0.000 n
Boundary Loads Acting East &West I #1 #lfl from 0.000fl to 0.000 fl
#2
#3
wfl from
#Ifl from
o.ooon to 0.000 n o.ooon to 0.000 n
#4 wn from 0.000fl to 0.000 fl
At North Wall
2nd zone
3rd zone
3rd zone
2nd zone
At South Wall
Center zone
in
2x 112'
2x
2x 1 R"
2x
112"
a 1 /2"
2x
1 lr'
112"
2x 112"
in
Structural II 1 Od 2,3,12
Structural II 1 Od
Structural II
2.5,3,12
1 Od 4,6,12
Structural II
Structural I1
1 Od
1 Od
6,6,12
Structural II 1 Od 2.5,3.12
4,6,12
Structural II 1 Od 2,3,12
#Iff
655.0
fl
575.0
0.00
385.0
0.00
0.00
290.0
385.0 0.00
575.0
655.0
0.00
0.00
Design Data 8 Nailing Requiremen
Shear Zone
Framing
At West Wall 2x
2nd zone
3rd zone
2x
2x
Center zone 2x
3rd zone 2x
2nd zone
At East Wall 2x
2x
I
[Shear & Chord Forces I Diaphragm Shears ...
Total Shear 0.Olbs O.Olbs 77.557.71bs 77,557.7 Ibs
Shear per Foot O.OO#lfl o.oown 570.28#lfl 570.28 wn
- North - South &&t East
Thickness
1M"
in
112
1 /2"
1M"
112e
112"
112"
Grade
Structural II
Structural I1
Structural II
Structural II
Structural /I
Structural II
Structural II
Nail Size
1 Od
1 Od
1 Od
1 Od
1 Od
1 Od
1 Od
Spacing
in
2.3,12
2.5,3,12
4,6,12
6,6,12
2.5,3,12
4,6.12
2,3,12
Value Distance
#lfl
655.0
fl
575.0
0.00
10.25
385.0
290.0
15.50
385.0 15.50
655.0
575.0 10.25
0.00
Chord Forces...
@? 114 Length
@? in Length
6,647.21bs
8,910.61bs
@? 314 Length 6,718.41bs
Length I Wldth Ratio 2.176
O.Olbs
0.Olbs
O.Olbs
(c) 1983-97 ENERCALC c:\enercaic~otl06.ecw KW-0602755, V5.0.2, 1-Jun-IS97
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Fax: (6191 485-6201
Phone: (619) 485-6227
Title : Lot 106 Redesign Drgnr: Date: Description :
Scope :
Job # 98244
I Horizontal Plywood Diaphragm uh
I General Information I
Description Floor
Diaphragm 6
North-South Length 136.00 fl Diaphrgm Weight 0.00 psf
EaseWest Length 67.50 ft Seismic Factor 0.1830
Nort-South Chord 136.00 fl Diaphragm is Blocked
East-West Chord 67.50 fl Blocking Direction North-South I Boundary Loads Acting North 8 South I #1
#2
5,000.00 #/fl from 0.ooofl to 0.000 fl
from 0.000ft to
#3 2,712.00 #lfl from 0.000fl to
0.000R
#4 #lft from 0.000fl to 0.000 fl
0.000 fl
5,ooo.oo wft
I Boundary Loads Acting East 8 West I #I wft from 0.ooott to
#2 wfl
#3 #Iff
from 0.000fl to 0.000 fl
from 0.000fl to 0.000 ft
0.000 n
#4 #lfl from 0.oooft to 0.000 n
Design Data 8 Nailing Requiremen
mina Thickness Grade Nail Size SDacino Value Distance
Shear Zone
At North Wall
2nd zone
2x
2x
3rd zone 2x
Center zone 2x
3rd zone
2nd zone
2x
At South Wall 2x
2x
1R"
in
1R"
112"
112"
112'
1R"
1R" __
Structural II
Structural II
Structural II
Structural I1
Structural II
Structural II
Structural ii
I
1 Od
in
2,3,12
1 Od 2.5,3,12
1 Od
1 Od
4,6,12
6,6,12
1 Od
1 Od
4,6,12
2.5.3,12
10d 2,3,12
#/a
655.0
ft
0.00
575.0 0.00
385.0
290.0
0.00
385.0 0.00
655.0
575.0 0.00
0.00
Deslgn Data 8 Nailing Requiremen
Shear Zone
Framing
At West Wall 2x
2nd zone 2x
3rd zone 2x
Center zone 2x
3rd zone
2nd zone
2x
At East Wall
2x
2x
Shear 8 Chord Forces
Thickness
in
1P
1 I2
1R"
112
1R"
112
1M"
Nail Size
1 Od
1 Od
1 Od
1 Od
1 Od
1 Od
1 Od
Spacing Value Distance
in #Ifl
2,3,12 655.0
fl
0.27
2.5,3,12 575.0
4,6,12 385.0
11.34
6,6,12
17.01
290.0
2.5,3,12
4,6,12 385.0 17.01
2,3,12
575.0
655.0
11.34
0.27
1
Grade
Structural It
Structural II
Structural II
Structural II
Structural Ii
Structural II
Structural II
Diaphragm Shears ... - North
Total Shear O.Olbs 78,512.5ibs 78,512.5 Ibs O.Olbs
Shear per Foot O.OO#/ft O.OO#lft 577.30#/fl 577.30 #/ft
y&t - East
Chord Forces... @ 114 * Length 7,267.31bs @ 1R Length 9,741.91bs
@ 314 Length 7,345.21bs
Length I Width Ratio 2.015
0.Olbs
0.Olbs
0.Oibs
(C) 1983-97 ENERCALC c:!mercalcVotl06.ecw KW-0602755, V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Dsgnr: Date: Description :
Scope : Fax: (619) 485-6201 L Horizontal Plywood Diaphragm 67 i
-
General Information
Description Roof 1
Diaphragm 7
North-South Length 136.00 n
Ease-West Length
Diaphrgm Weight
260.00 ft Seismic Factor 0.3000
Nort-South Chord 136.00 ft Diaphragm is Blocked
East-West Chord 260.00 n Blocking Direction North-South
0.00 psf
[ Boundary Loads Acting North & south^ 1 #1 #In from 0.000ft to 0.000 n
#2 #In from
#3
#4
o.ooon to
#/ft
0.000 ft
from o.ooon to
from o.ooon to 0.000 n #In 0.000 n
” __ [ Boundary Loads Acting East 8 West 1 #1 5.646.00 #/ft from o.ooon to o.ooo n
#2
#3
#In from 0.000ft to 0.000 ft
#Ift from 0.000R to 0.000 ft
#In from o.ooon to 0.000 n
Design Data 8 Nailing Requiremen
Thickness Grade Nail Size Spacing Value Distance
Shear Zone
At North Wall
2nd zone
2x
2x
3rd zone 2x
Center zone 2x
3rd zone
2nd zone
2x
At South Wall 2x
2x
112
in
112
1 /2
1 /2
112’
1 /2
1 I2
Structural i
in
10d
Structural I
2,3,12
1 Od
Structural I 1 Od
2.5,3,12
Structural I 1 Od
4,6.12
6,6,12
Structural I 10d
Structural I 1 Od
4.6,12
Structural I 10d
2.5,3.12
2,3,12
#/ft
730.0
ft
0.00
640.0
425.0
3.26
19.04
320.0
425.0
640.0
19.04
3.26
730.0 0.00
Design Data 8 Nailing Requiremen
Shear Zone
Thickness
in
1 /2
1 I2
1/2”
112
112
1 /2
112
Grade
Structural I
Structural I
Structural I
Structural I
Structural I
Structural I
Structural I
Nail Size
10d
1 Od
1 Od
1 Od
1 Od
1 Od
10d
Spacing Value
in
2,3,12
2.5,3,12
730.0
640.0
4,6,12
6,6,12
425.0
320.0
4,612 425.0
2.5,3,12 640.0
2,3,12 730.0
#/n
Distance
0.00
0.00
0.00
0.00
0.00
0.00
n
1
Framing
At West Wall
2nd zone
2x
2x
3rd zone 2x
Center zone 2x
3rd zone
2nd zone
2x
At East Wall
2x
2x
I -~ .1 [ Shear & Chord Forces
Diaphragm Shears... - South && - East North
Total Shear 115178.41bs 115178.41bs O.Olbs - 0.0 Ibs
Shear per Foot 442.99#/n 442.99#/ft o.oo#/n 0.00 #/ft
Chord Forces ...
@ 114 *Length 0.Olbs
@ 112 Length O.Olbs
@ 314 * Length 0.Olbs
Length I Width Ratio 1.912
11,235.91bs
15.061.81bs
11.356.31bs
(c) 198597 ENERCALC c:!enercalcUot106.ecw KW-0602755, V5.0.2. 1 Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 108 Redesign Job # 98244
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 4854227
Fax: (619) 485-6201
Dsgnr: Date: Description :
scope :
L Horizontal Plywood Diaphragm
Description Floor
Diaphragm 8
North-South Length 136.00 n
EaseWest Length 260.00 n Diaphrgm Weight 0.00 psf
Seismic Factor 0.1 830
Nort-South Chord 136.00 n Diaphragm is Blocked
East-West Chord 260.00 n Blocking Direction North-South 1 Boundary Loads Acting North 8 South 1 #1 #/ft from o.ooon to 0.000 n
#2
#3
#4
#I& from 0.000 ft
#/R from o.ooon to 0.000 n #/n from
o.ooon to
0.oooft to 0.000 n
~~~ I Boundary Loads Acting East 8 West
~ ~~~ ~ 1 #1 5,000.00 #/ft from o.ooon to 0.000 n
#2 5,ooo.oo #/n from 0.oooft to 0.000 n
#3 5,ooo.oo wn
#4 7,072.00 #In from o.ooon to
o.ooon to 0.000 R
0.000 n from
Design Data 8 Nailing Requiremen
Framing Thickness Grade Nail Size Spacing
Shear Zone
Value Distance
in
At North Wall 2x 1 /2” Structural iI 1 Od
2nd zone
2.3,12
2x
655.0
lL?
31.01
Structural I1 1 Od 2.5.3,12
3rd zone 2x 112” Structural II 1 Od
575.0 43.52
4,6,12
Center zone 2x
385.0
1 /2”
49.50
Structural II
3rd zone 2x lL? Structural II 4,6,12 385.0
1 Od 6,6,12
1 Od
290.0
2nd zone
49.50 2x 112” Structural I1
At South Wall 2x
1 Od
112 Structural ll
2.5,3.12 575.0
I Od 2,3,12 655.0
43.52
31.01
in #In n
Design Data 8 Nailing Requiremen
Framing
At West Wall 2x
2nd zone
3rd zone
2x
2x
3rd zone
Center zone 2x
2x
2nd zone 2x
At East Wail 2x
Thickness
In’
in
1n‘
1P
1P
1P
112”
In‘
Grade
Structural II
Structural I1
Structural II
Structural II
Structural It
Structural II
Structural II
Nail Size
1 Od
10d
I Od
1 Od
1 Od
1 Od
I Od
Spacing
in
2,3,12
2.5,3,12
4,6,12
6,6,12
2.5.3,12
4,612
2,3,12 LLl Shear Diaphragm 8 Chord Shears. Forces ..
Total Shear 274664.0ibs 274664.01bs
@JL7 West
0.Olbs - East 0.0 Ibs
Shear
Value #In
655.0
575.0
385.0
290.0
385.0
575.0
655.0
Distance
Zone
R
0.00
0.00
0.00
0.00
0.00
0.00
Shear per Foot 1,056.40#lft 1,056.4O#lft o.oo#/n 0.00 #Ift
Chord Forces ...
@ 114 * Length 0.Olbs
@ 112 Length
@ 314 * Length
0.Olbs
O.Olbs
Length I Width Ratio 1.912
26,794.01bs
35,917.61bs
27.081.3ibs
(C) 198597 ENERCALC c:\enercaic~otl06.ecw KW-0602755. V5.0.2, 1Jun-I997
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, Califwnia 92128
16959 Bemardo Center Dh, Suite 201
Phone (61 9) 4858227. Fan (619) 4858201
Project: Lot 106 Redesign
Job#: 98244 By:
SUBDIAPHRAGM DESIGN
WALL ANCHORAGE
Along Line..,
C. wall
1 EL 6. Roof I A EL 0, Roof
0.3 0.3
C, parapet
Height of Wall (ft)
Height of Parapet (ft)
Thickness of Wall (In)
Weight of Concrete (pd)
Center one half Increase
Force per foot (Ibs)
Anchor Force at 8' O.C. (Ibs)
473
3785
Use I See Purlin Design I Not Used
Anchor Force at 4' O.C. (Ibs) 1892
Use Not Used
12.75 13.5
3.25
145 145
1.5
424
3393
1097 1
L I Use PA 20 J
At center one half of diaphragm:
Force per foot 710 630
Anchor Force at 8' O.C. (Ibs) 5077 5090
Anchor Force at 4' O.C. (Ibs)
Use I See Purlin Design I
2838
Not Used
Use Not Used
2545 1
I Use PA 20 J
CROSS-TIES
Depth of Diaphragm (ft)
Width of Diaphragm (ft) 48 I
Diap. Ratio
34
Max. Diap. Ratio 4.0
0.2
10 48
Total Shear (Ibs)
1.4
4.0
J
2365 10179
Shear per foot (plf) 49
Allowable Shear per foot @lf) 320
Chord Force flbd
299
320 I
172 ama
OK I SeeRoof Plan I ." "1""
At center one half of diaphragm:
Depth of Diaphragm (ft) 48 I 48
Width of Diaphragm (ft) 10
Diap. Ratio
48
0.2
Max. Diap. Ratio
1 .o
4.0
Total Shear (Ibs) 3548
4.0
Shear per foot (plf) 15269
74
Allowable Shear per foot (plf) I 320
318
Chord Force (Ibs)
320
185 381 7
Use I See Roof Plan I
F
I I
L OK
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego. California 92128
16959 Bernardo Center Drive. Suite 216
Phone (619) 485-6227. Fax(619) 465-6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page 71
LATERAL ANALYSIS, continued I Drag and Chord Forces
ROOF:
Line 1 8 6 Chord Force = 15,062 I bs USE (2) #5 Bars
Line 3.5 Drag Force = 61,000 I bs
Line 4.7 Drag Force = 56,000 I bs
Line A & G Chord Force = 17.467 Ibs USE (2) #5 Bars
FLOOR:
Line I & 6 Chord Force = 35,918 Ibs USE L 5x3~112
Line 3.5 Drag Force = 138,719 I bs
Line 4.7 Drag Force = 101,561 I bs
Line A & G Chord Force = 40,399 Ibs USE L 5x3~112
Firouzi Consulting Engineers, Inc Tltle : Lot 106 Rederlgn Job # 98244
16959 Bernard0 Center Drive #202
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Dsgnr: Date: Description :
scope :
Timber Ledger Design
I General Information
Description ... Critical Case
Ledger Width Ledger Depth 3.500in Uniform Load ... 5.500in Dead Load Dead Load 0.00lbs 75.00 #/ft
Ledger is Bolted to Concrete Live Load
Bolt Diameter
100.OO#/ft Live Load 0.001bs
Spacing 0.00 ft
Bolt Spacing 24.000in Horizontal Shear 537.42#/ft Offset 0.OOin
Load Duration Factors ...
Point Load ...
314"
Live Load 1.250 Fb Allowable 1,000.0 psi Short Term 1.330 Fv Allowable 85.0 psi
[Ledger Stresses 1 DL + LL DL + ST DL+LL+ST
Maximum Moment
Bending Stress
700.00 in#
39.67 psi
Stress Ratio 0.032
MaximumShear 252.47 Ibs Shear Stress 13.12 psi Stress Ratio 0.123
300.00 in#
0.013
17.00 psi
108.20 Ibs 5.62 psi
0.050
700.00 in#
39.67 psi 0.030
252.47 Ibs
0.116
13.12 psi
- Bending & Shear OH
DL + LL Max. Vertical Load 350.00 Ibs DL + ST DL+LL+ST 150.00 Ibs 350.00 Ibs Allow Vertical Load 1,137.50 Ibs 1,210.30 Ibs
Max. Horizontal Load 0.00 Ibs 1,210.30 Ibs
Allow Horizontal Load 1,074.84 Ibs 1,787.50 Ibs 1,074.84 Ibs 1,901.90 Ibs 1,901.90 Ibs Angle of Resultant 90.0 degrees
Diagonal Component 350.00 Ibs
Allow Diagonal Force 1,137.50 Ibs
1,130.39 Ibs
1,803.12 Ibs
Final Stress Ratlo 0.308 : 1.00 0.577 : 1.00 0.627 : 1.00
7.9 degrees 18.0 degrees
1,oa5.26 Ibs
1,881.36 Ibs
__
(c) 1983-97 ENERCALC c:knercaicVotlO6,ecw KW-0602755, V5.0.2, 1Jun-1997
Firouzi Consulting Engineers, Inc Tltle : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201 Dsgnr: Date:
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Description :
Scope :
72
1 General Information I
Description Roof Drag Beam
Along Line 3.5
Between C & D
Steel Section W14X61 F
Column Height 28.500 n
End Fixity
Live 8 Short Term Loads Not Combined Y-Y Unbrace
Duration Factor 1.330
36.0 ksi X-X Sidesway : Restrained Y-Y Sidesway : Restrained
Kxz 1.000
Pin-Pin X-X Unbrace KYY 1.000 28.500 n
8.000 n I Loads 1 Axial Load ...
Dead Load k
Live Load
Short Term Load 61.00 k
Ecc. for X-X Axis Moments in
in k Ecc. for Y-Y Axis Moment
Distributed lateral Loads. .. - DL - LL ST Start &&
Along Y-Y wn s in
Along X-X 0.248 0.128 wn 3 28.500 in
Column Design OM
Section : W14X61, Height = 28.50RAxial Loads: DL = 0.00, LL = 0.00 ST = 61.00k. Ecc. = 0.000inU
Combined Stress Ratios DL + LL DL + Short
AlSC Formula H1 - 1
AlSC Formula H1 - 2
AlSC Formula H1 - 3 0.523 0.000 0.792 0.538 I
Stresses 1 Allowable B Actual Stresses Des DL + LL DL + Short
Fa : Allowable 17.70 ksi 17.70 ksi
fa : Actual 0.00 ksi 0.00 ksi
17.70 ksi
0.00 ksi 23.54 ksi 3.41 ksi
Fb:m : Allow [F1-6] 23.76 ksi 23.76 ksi
Fb:m: Allow [Fl-71 8 [Fl-81
23.76 ksi
23.76 ksi 23.76 ksi 23.76 ksi 31.60 ksi
31.60 ksi
fb : xx Actual 0.00 ksi 0.00 ksi 0.00 ksi 0.00 ksi
Fb:yy : Allow [Fl-61
Fb:% : Allow [F1-7]8 [Fl-81
27.00 ksi
27.00 ksi
27.00 ksi 27.00 ksi
27.00 ksi 27.00 ksi 35.91 ksi
35.91 ksi
fb : yy Actual 14.11 ksi 7.28 ksi 21.40 ksi 14.11 ksi 1 Analysis Values
F'ey : DL+LL
F'ex : DL+LL 45,648 psi Cm:x DL+LL 0.60 Cb:x DL+LL
96,859 psi 1.75
Cm:y DL+LL
F'ex : DL+LL+ST
1 .oo
60,712 psi
Cb:y DL+LL 1 .oo
Cm:x DL+LL+ST 0.60
F'ey : DL+LL+ST 128,822 psi Cm:y DL+LL+ST 1 .oo Cb:y DL+LL+ST 1.00
Cb:x DL+LL+ST 1.75
Max X-X Axis Deflection 0.000 in at 0.000 R
Max Y-Y Axis Deflection -1.799 in a 14.250 ft
(C) 1983-97 ENERCALC c:knercalc\otl06.ecw KW-0602755. V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Dieao. California 92128
Title : Lot 106 Redesign Job # 98244 Dsgnr: Description : Dale:
Phone: &i9) 485-6227 Scope :
Fax: (619) 485-6201 L 73
t 1 General Information
Description Roof Drag Beam
Along Line 4.7
Between 8.3 8 C
Steel Section W10X36 F
Duration Factor 1.330
Column Height 15.000fl
End Fixity Pin-Pin X-X Unbrace 15.000 fl
Live B Short Term Loads Not Combined Y-Y Unbrace
36.0 ksi X-X Sidesway : Restrained
Y-Y Sidesway : Restrained
Kxx 1.000
KY Y 1.000 8.000 n 1 Loads h Axial Load ...
Dead Load
Live Load
k
k
Short Term Load 56.00 k
Ecc. for X-X &is Moments in
Ecc. for Y-Y Axis Moment in
Distributed lateral Loads ... DL - LL - ST - Start End
Along Y-Y wn 3 in
Along X-X 0.315 0.180 wit 3 15.000 in
Column Design OK
Section : W16X36. Height = 15.00flAxiai Loads: DL = 0.00, LL = 0.00, ST = 56.00k. Ecc. = O.WOinU
Combined Stress Ratios Dead DL + LL DL + Short -
AlSC Formula H1 - 1 0.707
AlSC Formula H1 - 2 0.608
AlSC Formula H1 - 3 0.564 0.000 0.887
Stresses ~ ~ ~~~~ ~
Allowable 8 Actual Stresses
Fa : Allowable 17.11 ksi
Live
17.11 ksi
DL + LL
17.11 ksi
DL + Short
22 76 ksi -
fa : Actual 0.00 ksi 0.00 ksi 0.00 ksi 5.28 ksi
Fb:xx : Allow [F1-61
Fb:xx: Allow [Fl-71 8 [F1-8]
21.60 ksi 21.60 ksi
21.60 ksi
21.60 ksi
21.60 ksi 21.60 ksi
28.73 ksi
28.73 ksi
fb : xx Actual 0.00 ksi 0.00 ksi 0.00 ksi 0.00 ksi
Fb:yy : Allow [Fl-6] 27.00 ksi
Fb:m : Allow (Fl-718 (Fl-81 27.00 ksi 27.00 ksi
27.00 ksi 27.00 ksi
27.00 ksi
35.91 ksi
35.91 ksi
fb : yy Actual 15.23 ksi 8.70 ksi 23.94 ksi 15.23 ksi
". . .
I Analysis Values t F'ex : DL+LL 194,360 psi Cm:x DL+LL 0.60
F'ey : DL+LL 37,299 psi Cm:y DL+LL 1 .oo Cb:x DL+LL 1.75
Cb:y DL+LL
F'ex : DL+LL+ST
1 .oo
F'ey : DL+LL+ST
258,499 psi
49,607 psi
Cm:x DL+LL+ST
Cm:y DL+LL+ST
0.60
1.00
Cb:x DL+LL+ST 1.75
Cb:y DL+LL+ST 1.00
Max X-X Axis Deflection 0.000 in at 0.000 fl
Max Y-Y Axis Deflection -0.797 in a 7.500 ft
(c) 1983-97 ENERCALC c:knercalc\lotlO6.ecw KW-0602755, V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
San Diego, California 92128
Fax: (619) 485-6201
Phone: (619) 485-6227
Title : Lot IC6 Redesign
Dsgnr: Date: Descriptfon :
Scope :
Job # 98244
L 7t
1 I General Information
Description Roof Draa Beam
Along Li& 4.7
Between C & D
Steel Section Wl2X53 F 36.0 ksi Duration Factor 1.330
X-X Sidesway : Restrained
Y-Y Sidesway : Restrained
End Fixity
Column Height 28.500 n Ioo( 1.000
Pin-Pin
Live 8 Short Term Loads Not Combined Y-Y Unbrace
X-X Unbrace 28.500 n KYY 1.000
8.000 n I Loads 1 Axial Load...
Dead Load k Ecc. for X-X Axis Moments
Live Load k in
Short Term Load
Ecc. for Y-Y Axis Moment
47.30 k
in
Distrlbuted lateral Loads ... - DL - LL - ST Start End
Along Y-Y
Along X-X 0.315 0,180 wn wn 3 in
4 15.000in
Column Design OK
Section : WlW53, Height = 28.50ftAxial Loads: DL = 0.00, LL = 0.00, ST I 47.30k. Ecc. I 0.000inlJ
Combined Stress Ratios Dead DL + LL DL + Short
AlSC Formula H1 - 1
AiSC Formula H1 - 2
AlSC Formula H1 - 3 0.446 0.000 0.701 0.470
Stresses
Allowable 8 Actual Stresses Dead
Fa : Allowable 16.89 ksi 16.89 ksi 16.89 ksi 22.46 ksi
DL + LL DL + Short
fa : Actual 0.00 ksi 0.00 ksi 0.00 ksi 3.03 ksi
Fb:m : Allow [FI-61 23.76 ksi 23.76 ksi
Fb:m : Allow [Fl-71 8 [F1-8]
23.76 ksi
23.76 ksi 23.76 ksi 23.76 ksi 31.60 ksi
31.60 ksi
fb : xy Actual 0.00 ksi 0.00 ksi 0.00 ksi 0.00 ksi
Fb:yy : Allow [Fl-61 27.00 ksi 27.00 ksi 27.00 ksi
Fb:m : Allow [Fl-718 [F1-8]
35.91 ksi
27.00 ksi 27.00 ksi 27.00 ksi 35.91 ksi
fb : yy Actual 12.04 ksi 6.88 ksi 18.93 ksi 12.04 ksi
~~ ~
I Analysis Values I
F'ey : DL+LL
F'ex : DL+LL 34.783 psi Cm:x DL+LL 0.60
99,506 psi
Cb:x DL+LL
Cm:y DL+LL
1.75
F'ex : DL+LL+ST 46,261 psi
1.00
F'ey : DL+LL+ST 132,343 psi
Cm:x DL+LL+ST 0.60 Cb:x DL+LL+ST 1.75
Cm:y DL+LL+ST 1 .oo Cb:y DL+LL+ST 1.00
Max X-X Axis Deflection 0,000 in at 0.000 n
Max Y-Y Axis Deflection -1.443 in a 13.300 ft
1 .oo Cb:y DL+LL
(c) 1983-97 ENERCALC c:\enercalc\lotlOB.ecw KW-0602755, V5.0.2. 1-Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201 Dsgnr: Date:
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Description :
Scope :
L 7s
I I General Information
Description Floor Drag Beam
Along Line 3.5
Between C & D
Steel Section W14X99 F 36.0 ksi X-X Sidesway : Restrained
Duration Factor 1.330 Y-Y Sidesway : Restrained
Column Height
End Fixity Pin-Pin X-X Unbrace
Live 8 Short Term Loads Not Combined Y-Y Unbrace 8.000 n
28.500 n Kxx 1.000
28.500 n KY Y 1.000
I Loads
Axial Load ...
Dead Load k
Live Load
Short Term Load 139.70 k
Ecc. for X-X Axis Moments in
in k Ecc. for Y-Y Axis Moment
Distributed lateral Loads... DL - LL - ST Start End
Along Y-Y uft ”> in
Along X-X 0.520 0.423 kffl ”> 28.500 in
Section : W14X99. Height = 28.50RAxiai Loads: DL = 0.00, LL = 0.00, ST = 139.70k. Ecc. = O.WOinU
Combined Stress Ratios Dead DL + LL
AlSC Formula HI - 1
DL + Short
0.527
AlSC Formula HI - 2 0.487
AlSC Formula H1 - 3 0.425 0.000 0.771
Stresses h I I
Allowable 8 Actual Stresses &.& Live DL + LL DL + Short Fa : Allowable
fa : Actual
17.87 ksi 17.87 ksi 17.87 ksi 23.76 ksi 0.00 ksi 0.00 ksi 0.00 ksi 4.80 ksi
Fb:xx: Aliow[F1-6] 23.76 ksi
Fb:xx : Allow [Fl-7) 8 [Fl-81
23.76 ksi
23.76 ksi 23.76 ksi
23.76 ksi 31.60 ksi
23.76 ksi 31.60 ksi
fb : xx Actual 0.00 ksi 0.00 ksi 0.00 ksi 0.00 ksi
Fb:yy : Allow [F1-6] 27.00 ksi 27.00 ksi 27.00 ksi 35.91 ksi
Fb:xx : Allow [F1-7]& [F1-8] 27.00 ksi 27.00 ksi 27.00 ksi 35.91 ksi
fb : yy Actual 11.46 ksi 9.34 ksi 20.81 ksi 11.48 ksi I Analysis Values
F’ex : DL+LL 48.700 psi Cm:x DL+LL Cb:x DL+LL 1.75
F‘ey : DL+LL
0.60
223,842 psi
F‘ex : DL+LL+ST
Cm:y DL+LL 1.00 Cb:y DL+LL
64,771 psi
1.00
Cm:x DL+LL+ST
F‘ey : DL+LL+ST 297,710 psi
0.60
Cm:y DL+LL+ST 1 .oo Cb:x DL+LL+ST 1.75
Cb:y DL+LL+ST 1.00
Max X-X Axis Deflection 0.000 in at 0.000 fl
Max Y-Y Axis Deflection -1.201 in a 14.250 ft
(c) 1983-97 ENERCALC c:\enercalc\lotlOG.ecw KW-0602755, V5.0.2, 1 Jun-1997
16959 Bernard0 Center Drive #201
Firouzi Consulting Engineers, Inc
San Diego, California 92128
Fax: (619) 485-6201
Phone: (619) 485-6227
Title : Lot 106 Redesign
Dsgnr: Dale: Description :
scope :
Job # 98244
I 76 h
1 General Information - 1
~ Description Floor Drag Beams
Along Line 3.5
Between A & C
Steel Section W12X79 F 36.0 ksi X-X Sidesway : Restrained
Column Height 24.000 ft Ioo( 1.000
Y-Y Sidesway : Restrained
End Fixity
Live 8 Short Term Loads Not Combined Y-Y Unbrace
Pin-Pin X-X Unbrace 24.000 ft KYY 1.000
Duration Factor 1.330
8.000 ft
Loads
Axial Load ...
Dead Load
Live Load
Short Term Load 87.10 k
1
k Ecc. for X-X Axis Moments in
k Ecc. for Y-Y Axis Moment in
Distributed lateral Loads... - DL L - ST - Start End
Along Y-Y
Along X-X
wn
0.520 0.423 wft -2 In
4 28.500 in
Column Design OK
Section : WlW79, Height = 24.00flAxial Loads: DL = 0.00, LL = 0.00, ST = 87.10k, Ecc. = 0.000inU
Combined Stress Ratios Dead & DL + LL DL + Short
AlSC Formula H1 - 1 0.513
AISC Formula H1 - 2 0.481
AISC Formula H1 - 3 0.465 0.000 0.844
Stresses 1
Allowable 8 Actual Stresses Dead
Fa : Allowable 18.00 ksi 18.00 ksi 18.00 ksi 23.94 ksi
DL + LL DL + Short
fa : Actual 0.00 ksi 0.00 ksi 0.00 ksi 3.75 ksi
Fb:m : Allow [FI-61
Fb:xx: Aiiow [F1-7]& [FM]
23.76 ksi
23.76 ksi
23.76 ksi 23.76 ksi
23.76 ksi 23.76 ksi 31.60 ksi
31.60 ksi
fb : xx Actual 0.00 ksi 0.00 ksi 0.00 ksi 0.00 ksi
Fb:yy : Allow [Fl-61 27.00 ksi 27.00 ksi 27.00 ksi
Fb:xx : Allow [Fl-71 & [F1-8] 27.00 ksi 27.00 ksi 27.00 ksi 35.91 ksi
35.91 ksi
fb : yy Actual 12.56 ksi 10.22 ksi 22.70 ksi 12.56 ksi
[ Analysis Values
F'ex : DL+LL
Fey : DL+LL 150,860 psi
51,373 psi Cm:x OL+LL 0.60 Cb:x DL+LL 1.75
Cm:y DL+LL 1 .oo
F'ex : DL+LL+ST
Cb:y DL+LL
68,326 psi
1 .oo
F'ey : DL+LL+ST
Cm:x DL+LL+ST 0.60
200,644 psi
Cb:x DL+LL+ST 1.75
Cm:y DL+LL+ST 1 .oo Cb:y DL+LL+ST 1.00
Max X-X Axis Deflection 0.000 in at 0.000 ft
Max Y-Y Axis Deflection -1.124 in a 12.000 ft
(C) 1983-97 ENERCALC " c:knercalcUo~6.ecw KW-0602755, V5.0.2, 1 Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201
Dsgnr: Date: Description :
Scope :
L
[General Information I
Description Floor Drag Beam
Along Line 4.7
Between C & D
Steel Section W14X90 F
Column Height
End Fixity
Live 8 Short Term Loads Not Combined Y-Y Unbrace
Duration Factor 1.330
36.0 ksi X-X Sidesway : Restrained
Y-Y Sidesway : Restrained
28.500 n w
Pin-Pin X-X Unbrace Kyy 1.000
1.000
28.500 n
8.000 n I Loads I Axial Load ...
Dead Load k
Live Load k Ecc. far Y-Y Axis Moment
Ecc. for X-X Axis Moments in
Short Term Load 101.60 k
in
Distributed lateral Loads ... - DL - LL - ST
Along Y-Y
Along X-X
un
0.420
2 in
0.341 un 3 28.500 in
Summary 1 Column Design OK
Section : W14X90. Height = 28.50ftAxial Loads: DL = 0.00. LL = 0.00, ST = 101 Bok, Ecc. 0.000inU
Combined Stress Ratios - Dead - Live
AlSC Formula H1 - 1
DL + LL DL + Short
0.451
AiSC Formula H1 - 2 0.419
AlSC Formula H1 - 3 0.380 0.000 0.689 ,ek Stresses
I I
Allowable B Actual Stresses
Fa : Allowable 17.84 ksi
fa : Actual 0.00 ksi
17.84 ksi 17.84 ksi
0.00 ksi
23.72 ksi
0.00 ksi 3.83 ksi
Fb:xx : Allow (Fl-61 23.76 ksi
Fb:xx : Allow [Fl-71 8 [Fl-81 23.76 ksi
23.76 ksi
23.76 ksi
23.76 ksi
23.76 ksi
31.60 ksi
31.60 ksi
fb : =Actual 0.00 ksi 0.00 ksi 0.00 ksi 0.00 ksi
Fb:yy : Allow [Fl-61
Fb:xx : Allow (Fl-718 (Fl-81
27.00 ksi 27.00 ksi 27.00 ksi
27.00 ksi
35.91 ksi
27.00 ksi 27.00 ksi 35.91 ksi
fb : yy Actual 10.26 ksi 8.33 ksi 18.59 ksi 10.26 ksi
DL + LL DL + Short
I Analysis Values t F'ex : DL+LL 48,130 psi Cm:x DL+LL
Fey : DL+LL 221,346 psi Cm:y DC+LL
0.60 Cb:x DL+LL
1 .oo Cb:y DL+LL
1.75
F'ex : DL+LL+ST
1.00
64,013 psi
Fey : DL+LL+ST 294,390 psi Cm:y DL+LL+ST
Cm:x DL+LL+ST 0.60
1 .oo Cb:x DL+LL+ST 1.75
Cb:y DL+LL+ST 1.00
Max X-X Axis Deflection 0.000 in at 0.000 R
Max Y-Y Axis Deflection -1.076 in a 14.250 R
(C) 1983-97 ENERCALC c:\enercaicVotl06.ecw KW-0602755, V5.0.2, 1 Jun-1997
Firouzi Consulting Engineers, Inc Title : Lot 106 Redesign Job # 98244
16959 Bernard0 Center Drive #201 Dsgnr: Date:
San Diego, California 92128
Phone: (619) 485-6227
Description :
Scope : Fax: (619) 485-6201 L 78 1
General Information I
Description Floor Drag Beam Along Line 4.7
Between D & E
Steel Section W12X58 F Duration Factor 1.330
Column Height
End Fixity Pin-Pin
20.000 ft lea
X-X Unbrace 20.000 ft
Live 8 Short Term Loads Not Combined Y-Y Unbrace 8.000 ft
36.0 ksi X-X Sidesway : Restrained
Y-Y Sidesway : Restrained
1.000
Kyy 1.000
I Loads I Axial Load. ..
Dead Load k
Live Load
Short Term Load 68.30 k
Ecc. for X-X Axis Moments in
in k Ecc. for Y-Y Axis Moment
Distributed lateral Loads.. . - DL - LL - ST - Start
Along Y-Y Wft s in
Along X-X 0.420 0.341 uft s 28.500 in
Column Design OK
Section : W12X58. Height = 20.00ftAxial Loads: DL = 0.00, LL = 0.00, ST i. 68.30k, Ecc. I 0.000inU
Combined Stress Ratios "e- DL + LL DL + Short
AlSC Formula H1 - 1 0.499
AlSC Formula H1 - 2 0.468
AlSC Formula H1 - 3 0.437 0.000 0.791
"
Stresses
Allowable 8 Actual Stresses
Fa : Allowable 18.75 ksi 18.75 ksi 18.75 ksi
fa : Actual 0.00 ksi 0.00 ksi 0.00 ksi 24.93 ksi
4.02 ksi
Fb:xx : Allow [Fl-61
Fb:xx : Allow [Fl-71 8 [F1-8]
23.76 ksi
23.76 ksi
23.76 ksi
23.76 ksi
23.76 ksi
23.76 ksi
31.60 ksi
31.60 ksi
fb : xx Actual 0.00 ksi 0.00 ksi 0.00 ksi 0.00 ksi
Fb:yy : Allow [F1-6] 27.00 ksi 27.00 ksi 27.00 ksi
Fb:m : Aiiow [Fl-718 [F1-8] 27.00 ksi
35.91 ksi
27.00 ksi 27.00 ksi 35.91 ksi
fb : yy Actual 11.79 ksi 9.57 ksi 21.36 ksi 11.79 ksi
DL + LL DL + Short
Analysis Values 1 F'ex : DL+LL 72,439 psi Cm:x DL+LL 0.60 Cb:x DL+LL
F'ey : DL+LL 101,987 psi
1.75
Cm:y DL+LL 1 .oo
F'ex : DL+LL+ST
Cb:y DL+LL
96,344 psi
1.00
Cm:x DL+LL+ST
F'ey : DL+LL+ST 135,642 psi
0.60
Cm:y DL+LL+ST 1 .oo Cb:x DL+LL+ST 1.75
Cb:y DL+LL+ST 1.00
Max X-X Axis Deflection 0.000 in at 0.000 ft
Max Y-Y Axis Deflection -0.883 in a 10.000 ft
(c) 1983-97 ENERCALC "" c:\enercaicVoll06.ecw KW-0602755. V5.0.2, 1-Jun-1997
Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bernard0 Center Drive #201
Phone: (619) 485-6227
Fax: 6191 485-6201
Title : Lot 106 Redesign Dsgnr: Date: Description :
scope :
Job # 98244
1 General Information t
Description Floor Drag Beam
Along Line 4.7
Between E & G
Steel Section W12X53 F Duration Factor 1.330
Column Height 20.0oo ft Kxx 1.000
End Fixity Pin-Pin X-X Unbrace 20.000 ft KYY 1.000
Live 8 Short Term Loads Not Combined Y-Y Unbrace
36.0 ksi X-X Sidesway : Restrained
Y-Y Sidesway : Restrained
8.000 ft I Loads I
Axial Load ...
Dead Load k
Live Load k
Short Term Load 45.90 k
Ecc. for X-X Axis Moments in
Ecc. for Y-Y Axis Moment in
Distributed lateral Loads ... - DL L LL - ST Start End
Along Y-Y
Along X-X
wn
0.420 0.341 wn -a 28.500 in
in -2
Column Design OK
Section : W12yS3. Height = ZO.OWU\xial Loads: DL = 0.00, LL = 0.00, ST = 45.90k. Ecc. = 0.000inU
Combined Stress Ratios Dead - DL + LL DL + Short
AlSC Formula H1 - 1
AlSC Formula H1 - 2
AlSC Formula H1 - 3 0.487 0.000 0.882 0.484
I Allowable 8 Actual Stresses Dead
Fa : Allowable
fa : Actual
DL + LL DL + Short
18.70 ksi 18.70 ksi 18.70 ksi 24.87 ksi
0.00 ksi 0.00 ksi 0.00 ksi 2.94 ksi
Fb:xx : Allow [F1-6] 23.76 ksi 23.76 ksi 31.60 ksi
Fb:xx : Allow [F1-7] 8 [F1-8]
23.76 ksi
23.76 ksi 23.76 ksi 23.76 ksi 31.60 ksi
fb : xx Actual 0.00 ksi 0.00 ksi 0.00 ksi 0.00 ksi
Fb:yy : Allow [F1-6]
Fb:xx : Allow [Fl-71 8 [F1-8] 27.00 ksi
27.00 ksi 27.00 ksi 27.00 ksi
27.00 ksi 27.00 ksi
35.91 ksi
35.91 ksi
fb ', yy Actual 13.15 ksi 10.67 ksi 23.82 ksi 13.15 ksi
Analysis Values _" ~ _.___ 1
F'ey : DL+LL
Fex : DL+LL 70,631 psi Cm:x DL+LL 0.60
99,506 psi Cm:y DLtLL 1 .oo Cb:x DL+LL 1.75
Cb:y DL+LL
Fex : DL+LL+ST 93,939 psi Cm:x DL+LL+ST 0.60 Cb:x DL+LL+ST 1.75
1 .oo
F'ey : DL+LL+ST 132,343 psi Cm:y DL+LL+ST 1.00 Cb:y DL+LL+ST 1.00
Max X-X Axis Deflection 0.000 in at 0.000 ft
Max Y-Y Axis Deflection -0.986 in a 10.000 ft
(c) 1983-97 ENERCALC ____ ." c:\enercalcVot106.ecw MN-0602755, V5.0.2, 1 Jun-1997
~-
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego. California 92128
16959 Bemardo Center Drlve, Suite 201
Phone (619) 485-6227, Fax(619) 485-6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page 0
SHEARWALLS I Panel Designation: Line I, Roof
Panel Thickness (1) =
Total Shealwall Length (LJ =
Roof Seismic Load (Vd = 60000 PSI
Floor Seismic Load (V,J = LBS 0.85
Panel Length (Lp) = Area of Horiz. Bars (Avh) =
Height of Panel (HJ = Number of Layers (n) =
Horiz. Bar Spacing (sh) = IN
Horizontal Reinforcing: s2 = +f,&,nd/(vd-+Vc) = -31 .I IN
Ph = A,n/(tsh) = 0.0028 > 0.0025, OK
Area of Vert. Bars (&) =[-\INz Number of Layers (n) =I1
Vedica/Reinforcing: pv = .0025+.5(2.5-Hp/Lp)(ph-.0025) = 0.0027 > 0.0025, a
Sq = Awnl(tpv) = 14.114
FLOOR
Height of Lateral Force (Hv, Hfpd =
Framing Length (LP, Lip) = ml
Height of Opening (H,) = FT
Length of Opening (Lpo) = FT
Framing Dead Load (W,, W,) = 11 0 PSF
Panel Length Available for Shear (LPJ =(/FT
OT = (VmHrps + VIJ"pA 365444 LB-FT
RM = [(145)(t/12)(H,Lp-XH,L,)Lp+X(.5),L,L,L,112 390810 LB-FT
UPL = (OT - .85RM)/L, = 1386 LBS
Check Section 1921.6.5: A, = tLps/2 = 1152 INZ
p., = .IOA,f, = 345600 LB
V", = 3/,h(f,).5 = 15774 PLF > Vd.
pu = (OT+RM)/(.8Lp) 39388 LB < Pus,
Summary: - Use #5 (H) at 14" O.C. & #5 (Vj at 14" O.C., MIN. - Use (1) #5 Bar for Holdown - No boundary members required
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, Califomb 92128
16959 Bemardo Center Driva. Suite 201
Phone (619) 485-5227, Fax (619) 4858201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page ml
SHEARWALLS, continued
Panel Designation: Line 1, Floor (L Roof
Panel Thickness (t) =
Total Sheatwall Length (L) = f, =
Roof Seismic
Panel Length (b) = Area of Horiz. Bars (A,,.) =
Height of Panel (Hp) = Number of Layers (n) =
Horiz. Bar Spacing (sh) = IN
Horizontal Reinforcing: ~2 = +f&nd/(v&Vc) = -355.8 IN
Pa= 4h~(tsiJ = 0.0028 > 0.0025, OK
Area of Vert. Bars (A,.,) =[llNz Number of Layers (n) =[-
Vemcal Reinforcing: pv = .0025+.5(2.SHp/Lp)(h-.0025) = 0.0027 > 0.0025, OK
st = o/(tpv) = 14.588
FLOOR
Height of Lateral Force (HV, Hfp) =
Framing Length (Lrp, 4p, = mr
Height of Opening (HA = 6.75 FT
Length of Opening (Lpo) = FT
Framing Dead Load (W,, W,) = 11 45 PSF
Panel Length Available for Shear (Lp) =vlFT
OT = OImH, + VhHfp)Lpfl-. 1258179 LEFT
RM = [(145)(t/l2)(H,b-~H,~b+~(.5)~Lrpbb~2 646370 LE-FT
UPL = (OT - .85RM)/l, 29532 LBS
Check Section 1921.6.5 : & = tW2 = 1152 INz
P, = .lO&f, = 345600 LB
V, = 31,h(fJ.5 = 15774 PLF > v,,
p, = (OT+RM)/(.8Lp) c 99195.2 LB < p,,
Summary: - Use #5 (H) at 14" O.C. & #5 01) at 14" O.C., MIN. - Use (2) #8 A706 Bars per Detail 13C/SD1 - No boundary members required
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego. California 92128
16959 Bernard0 Center Drive. Suite 201
Phone (619) 485-5227. Fax (619) 485-6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page &
SHEARWALLS, continued
Panel Designation: Line 3.5, Roof
Panel Thickness (1) =
Total Shearwall Length (LJ = r, =
Roof Seismic Load (V,J =
fy=/ 6:r50 ~ /PSI Floor Seismic Load N,.) = $= ." I
Panel Length (Lp) =
Height of Panel (Hp) =
Area of Horiz. Ban (Ad =
Number of Lavers fn\ =
Horiz. Bar Spacing (shi =1Y/IN
Area of Vert. Bars (A,) =TlIN2 Number of Layers (n) =IT]
Vertical Reinforcing: pv = .0025+.5(2.5-Hp/Lp)(p,-.0025) = 0.0054 > 0.0025, OK
Sf = &n/(tpv) = 14.302
ROOF FLOOR
Height of Lateral Force (Hm, H,"J =I 15 I n I FT I~ -
Framing Length (Lrp, Lfp) =
0 Length of Opening (L,)'=
FT 0 0 Height of Opening (Hp) =
FT 0 8
FT 0
Framing Dead Load (W,, W,) = PSF 0 11
Panel Length Available for Shear (Lps) =~IFT
OT = (VrsHrpr + VfsHfpJLpsk = 811710 LE-FT
RM = [(145)(W12)(HpLp-~HpoLpo)Lp+Z(.5)~L,pLpLp]/2 = 504972 LB-FT
UPL = (OT - .85RM)/Lp = 14711 LBS
P", = .lOA,f, = 374400 LE
V", = 3/,h(fJ5 = 15774 PLF > Vd, OK
Check Section 1921.6.5: A, = tLp*/2 = 1248 IN2
pu = (OT+RM)/(.8Lp) = 63302 LB < Pus,
Summary: - Use (2) #5 (H) at 14" O.C. & (2) #5 (V) at 14" O.C.. MIN. - Use (1) #7 Bar for Holdown - No boundary members required
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 92128
16959 Bernard0 Center Drive, Suite 201
Phone (619) 485-6227, Fax (619) 485-6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov ‘98 Page
SHEARWALLS, continued
Panel Designation: Line 3.5, Roof & Floor
Panel Thickness (1) =
FT 52 Total Shearwall Length (LJ
IN 12
Roof Seismic Load (V,) =
LBS 246610 Floor Seismic Load (Vk) =
LBS 108228
d =[ 12 ]IN
+Vc = +2(f‘J5dt = 13408 PLF
Vd 1.4(Vm+V~/(0.8LJ = 11942 PLF < +Vc, Q!S
Panel Length (Lp) = FI;; Area of Horiz. Bars (&) =
Height of Panel (Hp) = Number of Layers (n) =
Horiz. Bar Spacing (sh) HINZ IN
Horizontal Reinforcing: s2 = $f&nd/(vd-+V,) = -258.7 IN
Ph = A,qJl/(tSh) = 0.0037 > 0.0025, OK
Area of Vert. Ban (Aw) =IllN2 Number of Layen (n) =TI
Vedical Reinforcing: pv = .0025+.5(2.5-Hp/Lp)(ph-,0025) = 0.0036
s, = A,.,n/(tpJ = 14.221
ROOF FLOOR
Height of Lateral Force (HV, Hfp3 =
8 I AS FT FraminD Length (Lm. Ld =
16 FT 31
- - . .-.
Height of Opening (HP) = 0 FT 0
.r.
Length of Opening (LP) = FT 0 0
Framing Dead Load W,. WJ = PSF 11 I An - . .. .. .- I
Panel Length Available for Shear (L,) =l-IFT
OT = WnHrps + VkHtpskpsk = 7300828
RM = ((145)(t/12)(HpLp-~HwLP)Lp+~(.5)~LrpLpLp]/2 = 6312488
UPL = (OT - .85RM)/Lp = 37216
Check Section 1921.6.5: A, = tLps/2 = 3744 IN2
P, = .lOAsfF = 11 23200 LB
V”, = 3f,h(fJ5 = 23662 PLF > vd,
Pu = (OT+RM)/(.8Lp) = 327243 LB < Pum OK
Summary: - Use (2) #5 (H) at 1.I“ O.C. & (2) #5 (V) at 14“ O.C., MIN. - Use (2) #8 A705 Bars per Detail 13CISDI - No boundary members required
> 0.0025, OK
LB-FT
LB-FT
LBS
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego. California 92128
16959 Bernard0 Center Drive. SuRe M1
Phone (61 9) 4856227. Fax (61 9) 4856201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page B
SHEARWALLS, continued I Panel Designation: Line 4.7, Roof
Panel Thickness (t) =
Total Shearwall Length (L,) =
~I~T !TIIN
3000 PSI
Roof Seismic Load (V,) = 73089 LBS = 60000 PSI
Floor Seismic Load (V,$) = LBS 0.85 f"
WC = +2(fJ5dt = 8939 PLF
Vd = 1.4(V,+V&/(0.8Ls) = 5814 PLF < +V,. E
Panel Length (Lp) = Area of Horiz. Bars (Avh) =
Height of Panel (H,) = Number of Layers (n) =
Horiz. Bar Spacing (sh) = IN
Horizontal Reinforcing: s2 = +ffivhnd/(vd-,+,vc) -60.7 IN
Ph = Avhn/(tsh) = 0.0028 > 0.0025, OK
Height
Area of Vert. Bars (A,) =r/lN2 Number of Layers (n) =TI
ROOF FLOOR
of Lateral Force (HIPS, HIP) =
FT n 8.5 Height of Opening (H,) =
FT 0 8 Framing Length (LIP, Lfp) =
FT 0 15
Length of Opening (L,) =
Framing Dead Load (Wr, W,) =
Panel Length Available for Shear (Ld =mFT
OT = (Vdrps + Vd~ps)Lps/Lr = 1096335 LE-FT
RM = [(145)(t/12)(HpLp-~H,Lw)Lp+X(.5),L,pLpLp]/2 = 512211 LE-FT
UPL = (OT - .85RM)/Lp = 23775 LBS
P", = .lOAgfc = 400320 LB
V", = 3/,h(rJ5 = 15774 PLF > Vd, E
Check Section 1921.6.5 : 4 = tLp,/2 = 1334.4 IN2
pu = (OT+RM)/(.BLp) = 72327 LB P,,, OK
Summary: - Use #5 (H) at 14" O.C. & #5 (V) at 14" O.C., MIN. - Use (1) #8 Bar for Holdown - No boundaly members required
FlROUZl
CONSULTING
ENGINEERS, INC.
Sen Diego. California 92128
16959 Bemardo Center Drive, Suite 201
Phone (619) 485-6227. Fax (619) 485-6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page fi
SHEARWALLS, continued 1 Panel Designation: Line 4.7, Roof & Floor
Panel Thickness (t) = rl; LI;"IIN
Total Shearwall Length (L,) = 37.5 f, = 3000 PSI
Roof Seismic Load (VJ = 73089 LBS f, = 60000 PSI
Floor Seismic Load (VIS) = 156071 LBS 0.85
$vc = $2(fJ5dt = 13408 PLF
Vd = 1 .4(V,,+Vls)/(0.8L3 = 10694 PLF < $V,, OK
Panel Length (L,) = Area of Horiz. Bars (4 =
Height of Panel (Hp) = Number of Layers (n) =
Horiz. Bar Spacing (sh) = IN
Area of Vert. Bars (A,) =TlIN2 Number of Layers (n) =TI
Height of Lateral Force (Hrps, HIPS)
Framing Length (L,,, LIP)
Height of Opening (Hpo)
Length of Opening (L,)
Framing Dead Load (W,, Wl)
ROOF FLOOR - - 30 14 FT - - 8 FT 5.25 - - FT Id Q 19.5 I , ~. .- I - - 19.5 14.3 FT - - 11 I 45 PSF
Panel Length Available for Shear (LpJ =r]FT
OT = (VmHrp + v181ps)LpJLs = 4377664 LB-FT
RM = [(145)(t/12)(HpLp-~Hp,Lpo)Lp+~(.5),L,L,L,]/2 = 2481 100 LB-FT
UPL = (OT - .85RM)/L, = 52761 LBS
P", = .I OA,f, = 928800 LB
vu, = 3iwh(rJ5 = 23662 PLF > Vd, OK
Check Section 192 1.6.5 : A, = tL,/2 = 3096 IN2
pu = (OT+RM)/(.BLp) = 199383 LB < pus,
Summary: - Use (2) #5 (H) at 14" O.C. & (2) #5 (V) at 14" O.C., MIN. - Use (2) #8 A706 Bar per Detail 13DISDI - No boundary members required
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego. California 92128
16959 Bernard0 Center Drive. Suite 201
Phone (619) 485-6227. Fax (619) 485-6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page &
SHEARWALLS, continued
Panel Designation: Line 6, Roof
Panel Thickness (1) =
Total Shearwall Length (LJ =
Roof Seismic Load (VJ = 60000 PSI
Floor Seismic Load (V,) = LBS 0.85
$V, = $2(fJ5dt = 8939 PLF
Vd = l.4(V,+V~)/(0)1(o.8L,) = 2460 PLF +v0, OK
Panel Length (L,) = Area of Horiz. Bars (A,,,,) =
Height of Panel (H,) = Number of Layers (n) =
Horiz. Bar Spacing (sh) = IN
Horizonfal Reinforcing: s2 = $f&nd/(vd-QVc) = -29.3 IN
Pn = Avhn/(fSh) = 0.0028 > 0.0025, OK
Area of Vert. Bars (AJ =TlIN2 Number of Layers (n) =-
Veflical Reinforcing: pv = .0025+.5(2.5-Hp/Lp)(p,.0025) = 0.0027
Sq = Ad/(t&) = 14.347
ROOF FLOOR
Height of Lateral Force (Hw, HfpJ =
Framing Length (LrP, Lfp) =ml
Height of Opening (Hpo) = 6.75 FT
Length of Opening (Lpo) = FT
Framing Dead Load (W,, W,) = 11 PSF
Panel Length Available for Shear (Lpa) =(]FT
OT = (VmHrps + VfsHf&& = 168666
RM = [(145)(t/i2)(HpLp-~H,Lpo)Lp+~(.5),L,pL,L,]/2 = 158033
UPL = (OT - .85RM)/Lp = 21 46
Check Section 1921.6.5: A, = tL,/2 = 768 IN2
P", = .IOA,f, = 230400 LB
V", = 3l,h(fJ5 = 15774 PLF > vd, OK
pu (OT+RM)/(.BLp) = 25523 LB P,,, OK
Summary: - Use #5 (H) at 14" O.C. & #5 o/) at 14" O.C., MIN. - Use (1) #6 Bar for holdown - No boundary members required
> 0.0025, OK
LB-FT
LB-FT
LBS
FlROUZl
CONSULTING
ENGINEERS, INC.
San Diego, California 921 28
16S59 Bernard0 Center Drive, Suite 201
Phone (619) 4858227, ax (619) 4856201
Project: Lot 106 Redesign
Job #: 98244 Bv:
Date: Nov '98
-I
Page
SHEARWALLS, continued
Panel Designation: Line 6, Roof (L Floor
Panel Thickness (t) =
Total Shearwall Length (w =
Roof Seismic Load (V,,) 37949.9 LBS 60000 PSI
Floor Seismic Load (Vh) = 78513 LBS += 0.85
+VC= @(fJ5dt= 8939 PLF
Vd = 1.4(Vn+Vh)/(0.8L,) = 3919 PLF +Vc, OK
Panel Length (Lp) = Area of Horiz. Bars (u =
Height of Panel (HJ = Number of Layers (n) =
Horiz. Bar Spacing (s,J = IN
Horizontal Reinforcing: s;! = +f,&nd/(vd-+VJ = -37.8 IN
Ph = &ilwts,J = 0.0028 > 0.0025, OK
Area of Vert. Bars (A,.,) =TlIN2 Number of Layers (n) =TI
FLOOR
Height of Lateral Force (HW, Hfp) =
Framing Length (b, 4p, =
Height of Opening (Hd = FT
Length of Opening = FT
Framing Dead Load (W,. W,) = 11 45 PSF
Panel Length Available for Shear (m =I 16 IFT
OT = (ViaH, + vhhp$Lp$L = 700194
RM = 1(145)(1/12)(H,l,-~H,LdL,+~(.5),L~~l,]/2 = 494247
UPL = (OT - .85RM)/l, 17505
Check Seclion 1921.6.5: 4 = 'U2 = 768 IN2
P", = .lOAJ0 = 230400 LB
V, = 3/&(fJ5 = 15774 PLF > v,,
pu (OT+RM)/(.8Lp) = 93318 LB < P,, OK
Summary: - Use #5 (H) at 14" O.C. & #5 (V) at 14" O.C., MIN. - Use (I) #7 A706 Bar per Detail 5B/SDI - No boundary members required
LB-FT
LB-FT
LBS
FlROUZl
CONSULTING
ENGINEERS, INC.
16959 Bernard0 Center Drive, Suite 201
San Diego, California 92128
Phone (619) 485-6227, Fax (619) 485-6201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page Sg
SHEARWALLS, continued
Panel Designation: Line A, Roof
Panel Thickness (1) =
Total Shearwall Lenath (L.) =
Roof Seismic
Floor Seismic Load (V,) =
r, = =LFl~sl
f, =)600001PSI
@VC= @(f'J5dt = 8939 PLF
Vd = 1 .4(V,,+V1,)/(O.8Ls) = 2290 PLF < $vc, OK
Panel Length (Lp) = Fl;; Area of Horiz. Bars (kh) =
Height of Panel (Hp) = Number of Layers (n) =
Horiz. Bar Spacing (s,J = #" IN
Horizontal Reinforcing: s2 = +f&nd/(vd-@VC) = -28.5 IN
Pn = A*n/(tSh) 0.0028 > 0.0025. OK
Area of Vert. Bars (A,) =TIIN* Number of Layers (n) =-
ROOF FLOOR
Height of Lateral Force (Hrps. HIP,) -
Framing Length (LW, Lfp) imr
Height of Opening (H,) = FT
Length of Opening (Lpo) = FT
Framing Dead Load (W,, Wl) = 11 0 PSF
Panel Length Available for Shear (Lp6) =rjFT
OT = (VmHrps + VIshp&psk = 151 826
RM = [(145)(t/12)(HpLp-ZHpoLpo)Lp+Z(.5)~LrpLpLp]/2 21 1725
UPL = (OT - .85RM)/Lp = -1655
Check Section 1921.6.5: A, = tL,/2 = 816 INZ
Pua = . 1 OA,f = 244800 LB
V". = 3/,.,h(fJ5 = 15774 PLF > Vd, OK
Pu = (OT+RM)/(.BLp) = 26732 LB < Pun, OK
Summary: - Use #5 (H) at 14" O.C. 8 #5 (v) at 14" O.C., MIN. - No holdown required - No boundary members required
> 0.0025,
LB-FT
LB-FT
LBS
FlROUZl
CONSULTING
ENGINEERS, INC.
16959 anmardo Center ~rivs, Suite MI
san ~iego, canrcmb 921 28
Phone (6t9) 4858227. Fu (619) 4858201
Project: Lot I06 Redesign
Job #: 98244 By:
Date: Nov '98 Page a1
SHEARWALLS, continued
Panel Designation: Line A, Roof it Floor
Panel Thickness (1)
Total Sheatwall Length (LJ
Roof Seismic Load (VR)
Floor Seismic Load (Vd
Panel Length (L& =
Height of Panel (HJ =
Horizonta/ Reinforcing: ~2 = +f,A.,,nd/(v.,-+V~ =
Ph = &lw%J =
Area of Vert. Bars (L) =I 0.31 I IN2
f, = =pF$s1
+=
PLF
7376 PLF < +Vc, OK
Area of Horiz. Bars (A,,,,) =
Number of Lavers In) =
-121.4 IN
0.0028 > 0.0025, OK
Number of Lavers In) -TI . ... - . .I
Vertical Reinforcing: pv = .0025+.5(2.5-Hp/Lp)@,-.o025) = 0.0027
St = &ll/(tpv)= 14.449
ROOF FLOOR
Height of Lateral Force (H
Framing Length (L,,,, L,J = FT
Height of Opening (Hd = 8.75 FT
Length of Opening (L,J = 18 20 FT
Framing Dead Load (W,, W,) = 45 PSF
Panel Length Available for Shear (Lp) =mFT
OT = OImH, + vhHtp)Lp/L. = 582674
RM [(145)(ffl2)(H,b-CH,~~+C(.5)~~b~/2 = 1092658
UPL (OT - .85RM)/b = -12360
Check Section 192 1.6.5 : 4 = tw2 = 1344 IN2
P, = .IO%f, = 403200 LB
V, = 3/,h(fa5 = 15774 PLF > v,,
pu = (OT+RM)/(.8Lp) = 74792 LB < P,, a
Summary: - Use #5 (H) at 14" O.C. & #5 (V) at 14" O.C., MIN. - No holdowns required - No boundaly members required
> 0.0025, OK
LSFT
LB-FT
LBS
FlROUZl
CONSULTING
ENGINEERS, INC.
San DL. Cdifomla 921 28
16959 Bemardo Center Drhre, Sule 201
PhMe (619) 485BpI. FU (619) 4858201
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page BO
SHEARWALLS, continued
Panel Designation: Line 0, Roof
Panel Thickness (1) =
Total Sheatwall Length (LJ = 3000 PSI
Roof Seismic Load (Vd = 80000 PSI
Floor Seismic Load (Vh) = LBS 0.85
+VC = @(fJ5dt = 8939 PLF
Vd = 1 .4(Vm+Vh)/(0.8LJ = 2879 PLF < +Vc, OK
Panel Length (LJ = Area of Horiz. Bars (m =
Height of Panel (HJ = Number of Layers (n) =
Horiz. Bar Spacing (sd = IN
Area of Verl. Bars (AJ =-IN2 Number of Layers (n) =-
Ve&al Reinforcing: pv = .oo25+.5(2.~~p/~p)(~-.oo25) = 0.0028
Si = &ll/(tpv) = 14.049
ROOF FLOOR
Height of Lateral Force (HP, H,J =
Framing Length (b, L,J =mF
Height of Opening (Hd = 6.75 FT
Length of Opening (L,.J = FT
Framing Dead Load (W,. W,) = 11 PSF
Panel Length Available for Shear (Lp) =~FT
OT = (VmHrp + V&pJLp/L. 227066
RM [(145)(1/12)(H,~-~H,L,.J~*~(.5)~~~~~ = 567989
UPL = (OT - .85RM)/Lp = -9133
Check Section 1921.6.5 : A,, = tu2 = 1344 IN2
P, = .1oA,,r0 = 403200 LB
V". = 3l&(fJ5 = 15774 PLF > Vd, OK
pu= (OT+RM)/(.8Lp)= 35494 LB < P,, a
Summary: - Use #5 (H) at 14" O.C. & #5 01) at 14" O.C., MIN. - No holdowns required - No boundary members required
> 0.0025,
LB-FT
LBFT
LBS
FlROUZl
CONSULTING
ENGINEERS, INC.
San Olego, Califomla 92128
113959 Bsrrurdo Canter Drive, Sub 201
Phone (619) 4@562?7. Fax (819) 4858p1
Project: Lot 106 Redesign
Job #: 98244 By:
Date: Nov '98 Page gP(
SHEARWALLS, continued
Panel Designation: Line 0, Roof (L Floor
Panel Thickness (1) =
Total Shearwall Length R) =
Roof Seismic Load (V,J =
Floor Seismic Load (Vh) =
rc =Rab"Sl =
fV =("IPS1
0 'L 0.85
Panel Length (Lp) = Area of Horiz. Bars (A,,,) =
Height of Panel (H,,) = Number of Layers (n) =
Horiz. Bar Spacing (sh) = IN
Horizontal Reinforcing: ~2 = $f,&nd/(vC$VJ = -140.3 IN
h= A,+Jl/(tsh) = 0.0028 =. 0.0025, OK
Area of Vert. Bars (A,.,) =lTlIN2 Number of Layers (n) =TI
ROOF FLOOR
Height of Lateral Force (lip, H& =
Framing Length (Lrp, L,J =mi::
Height of Opening (HPO) = Fr
Length of Opening (Ld = Fr
Framing Dead Load (VUr, W,) = 45 PSF
Panel Length Available for Shear (Lp) =18Ifl
OT = WmHp + V&&LplL = 600309
RM = [(145)(W12)(Hpb-~H,~b+~(.~,LrpL,~/2 = 1419586
UPL = (OT - .85RM)/L, = -21655
Check Section 1921.6.5: A, = '42 = 1344 INz
P, = .I OAJ, = 403200 LB
V, = 3/Jl(f3.5 = 15774 PLF > v.,,
pu = (OT+RM)/(.8Lp) = 90174 LB C P,,
Summary: - Use #5 (H) at 14" O.C. 8 #5 o/) at 14" O.C., MIN. - No holdowns required - No boundary members required
> 0.0025, OK
LB-FT
LB-FT
LBS
FlROUZl
CONSULTING
! ENGINEERS, INC.
1- Bemardo Center Drlva, Sub 201
San Dlego. CaUfornh 92126
Ph (619) 4854227, Fax (610) 4858201
I
.i Project: Lot 106 Redesign
Job Y: 98244 By:
Date: Nov ‘98 Page&
I DESIGN VALUES, continued
SOIL
Soils Report By: Christian Wheeler Engineering
Job No.: CWE 198.125.1
Allowable Bearing Pressure = 1830+210(2’)+60(2.75’) = 2400 psf (continuous)
= U00+210(2’)+50(4.5’) = 2800 psf (isolated)
= 24 in. (isolated)
Minimum Footing Width = 24 in. (continuous)
Expansion Index = 94
I STEEL Pipe Columns: ASTM A53 Grade E, Fy=35 ksi, F.40 ksi
Tube Columns: ASTM A500 Grade B, F~46 ksi, F,=58 ksi
Other Shapes: ASTM A36, F,=36 ksi
CONCRETE
Foundation, Slab, & Tilt-up Walls:
CODE 8 PUBLICATIONS
PC = 3000 psi
UBC 1994 Edition
AISC, Ninth Edition
PC1 Design Handbook, Fourth Edition
Nelson Stud Welding Handbook for Non-Residential Construction
Simpson Strong-Tie Connectors
I WOOD SHEARWALLS
I denotes double-sided sheatwall (plywood shall be staggered on each side)
FIROUZI
CONSULTING
ENGINEERS, INC.
1- Eerwdo Center D~ive. Sub 201
Sm Dm, California 92128
Pho~ (619) 4858221. Fax (619) 4858201
Project: Lot 108 Redesign
Job 08244 By:
Date: Nov'98 Page g@
FOUNDATION DESIGN
Continuous Footings
Floor DL = 56 PSF
Reduced Floor LL = 50 PSF
Weight of Concrete = 145 PCF
blona Line 4
Wall Thickness =
Wall Height =
Roof Trib. Width =
Floor Trib. Wdth =
Alona I ine G
Wall Thickness =
Wall Height =
Roof Trib. Width =
Floor Trib. Width =
Alono Lines 1 & 6
Wall Thickness =
Wall He$ht =
Roof Trib. Wth =
Floor Trib. Wdth =
8
32
24
12
8
32
30
30
8
32
5
3.5
IN
Fr
Fr Fr
IN Fr
Fr Fr
IN
Fr
Fr
Fr
Roof DL = 15 PSF
Reduced Roof LL 12 PSF
WW= 4125 PLF
wU= 8aa PLF
WW= 6223 PLF
WU= 1500 PLF
WW' 3364 PLF
W== 176 PLF
Spread Footings
D 6 5.5, Floor Only Rf + Flr
1.56 8 488 LhC UneC 081.52.5 06213 0645
Floor Area (e)
80 100 100 80 80 80 Floor LL (ps9 80
56 67.5 67.5 56 56 56 56 Floor DL (ps9
936 1144 1144 683 683 750 624
R = .08(A - 150) 38 48 43 43 80 80 63
R < 23.1(1 + DL) 39 39 39 39 39 39 39
and R < 40 (1-stow)
and R 60 iotherij
R used 38 I 39 I 39 I 39 I 39 I 39 I I
Reduced Floor LL 50 49 49 49 61 61 49
39
Roof Area (f?)
0 0 0 0 0 0 0 Roof LL (ps9
15 15 0 15 0 0 0 Roof DL (ps9
2288 2288 0 1989 0 0 0
PDL (kips) 34.9 42.0 38.2 68.1 77.2 111.5 86.7
PLL (kips) U! 3s 3x3 3x3 45.7
Total Load (kips) 65.9 78.6 71.6 101.4 147.0 181.3 132.4 -
FlROUZl
ENGINEERS, INC.
18959 Bemardo C& Dfive, Sub 201
Sari Diego. Callfomio 92128
CONSULTING
Ph (619) 4858227, FaX (619) 4E-6201
Project: Lot 106 Redesign
Job #: 98244 w
Date: Nov'98 Page a
FOUNDATION DESIGN, continued
Spread Footings, continued
Floor DL (p$
Floor LL (ps9
R c 23. l(1 + DL)
and R c 40 (I-story)
and R c 60 (others)
Reduced Floor LL
R used
Roof Area (ft)
Roof DL (ps9
Roof LL (ps9
R = .08(A - 150)
PDL (kips)
PLL (kips)
Total Load (kips)
UnesE8F
Floor Area Cf?) 520
56
80
30 -12
39
-12
#DIV/OI
-12
#DM01
-12
#DIV/OI
-12
#DIV/OI #DIV/OI
-12
#DIV/Ol
1 30 I I 1 1 1 1 I 56 0 0 0 0 0 0
0
0
0
29.1 0.0 0.0 0.0 0.0 0.0 0.0
2Itl !u ep !22Q !u e;e Q9
58.2 0.0 0.0 0.0 0.0 0.0 0.0
'Firouzi Consulting Engineers, Inc Title: LaIiWRedsoion Job # 98244
16959 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 4854227
Fax: (619) 4854201
Dsgnr: Date: mscripuon :
swp :
General Footing Analysis 81 Design K5-7-
[General Information I
Description Continuous Footings
Along Lines A, 1 8 6
Allowable Soil Bearing 2,400.0 psf Dimensions. ..
Short Term Increase 1.330 in Width along X-X Axis 2.750 ft
Base Pedistal Height 0.000 in Length along Y-Y Axis 1.000n
Seismic Zone 4 Footing Thickness 15.00 in
Overburden Weight 0.00 psf Col Dim. Along X-X Axis
Live 8 Short Term Combined
9.00 in
Coi Dim. Along Y-Y Ads 12.00 in
Min Steel 0.0014
Rebar Cover 3.00 in
rc
FY
3,000.0 psi
60,000.0 psi
145.00 pcf Concrete Weight r Loads h
Applied Vertical Load...
Dead Load
Live Load
4.230 k ... ecc along X-XAxis 0.000 in
0.890 k
Short Term Load k
... ecc along Y-Y Axis 0.000 in
Creates Rotation about Y-Y Axis Creates Rotation about X-X Axis
Applied Moments... (pressures @ left 8 right)
Dead Load
Live Load k-n k-fl
Short Term k-ft k-ft
k-ft
(pressures @ top 8 bot)
k-ft
Creates Rotation about Y-Y Axis Creates Rotation about X-X Axis
Applied Shears... (pressures @ left & right) (pressures @top 8 bot)
Dead Load k
Live Load k
Short Term k
k
k
k
Footing Design OM
2.75 R x 1 .OO R Footing, 15.0 in Thick, w/B.OO x 12.00 in column 0.0 in high I Max Soil Pressure
DL+LL DL+LL+ST
2.043.1 2.043.1 DSf Max Mu/Phi 1.501 k-fl
Actual Allbwable
Allowable 2,400.0 3i192.0 prf Required Steel Area 0.202 in2
"X' Ecc, of Resultant 0.000 in 0.000 in
"Y' Ecc. of Resultant
Vu : 1-Way
0.000 in 0.000 in 2.623 186.226 psi
0.000 Vu : 2-Way 93.113psi
X-X Min. Stability Ratio ggg,ooo:1
Y-Y Min. Stability Ratio gQg,ooo:1 1.500 :1
(c) i-7 ENERCALC c:\awrcak\btiOE.aw Kw480275.5, V5.0.2,i Jun-1997
1
'Firouzi Consulting Engineers, Inc
16969 Bernard0 Center Drive #201
San Diego, California 92128
Phone: (619) 4864227 Fax: (619) 4864201
General Footing Analysis 8 Design
LFooting Design
Shear Forces Two-way Shear 2.62 2.53 1.34 psi 186.23 psi
One-Way Shea rs...
Vu/Phi @ LeR 0.00 0.00 0.00
Vu/Phi @ Right
93.11 psi
0.00 0.00
Vu/Phi @ Top
0.00
0.00 0.00 0.00 93.11 psi
93.11 psi
VulPhi @ Bottom 0.00 0.00 0.00 93.11 psi
Vn * Phi
Moments As Rw'd MulPhi @ LeR 1 .so 1.45 0.77 k-R 10.4 Dd 0.20 in2 AG!B BL
MulPhi 6 Right 1 SO 1.45 0.77
MulPhi @ Top 0.00
10.4 0.20
0.00 MulPhi @ Bottom 0.00
0.00
0.00
0.0 0.02
0.00 0.0 0.02 1 Soil pressure Summary 1 Service Load Soil Pressures Left Rioht Ton Bottom DL + LL
DL+LL+ST
2,043.07 2,Gh7
2,043.07
2,04i07
2,043.07
2,043.07 psf
2,043.07 2,043.07 psf
.. - -. . -. . .
Factored Load Soil Pressures
ACI Eq. 9-1 2,957.39
ACI Eq. 9-2
2,957.39
2,860.30 2,860.30
2,95739 2,957.39 psf
2,860.30
ACI Eq. 9-3 1,547.49 1,547.49 1,547.49 1,547.49 psf 2,860.30 psf
ACI Factom (per ACI, applied internally to entered loads) 1 ACI 9-1 a 9-2 DL
ACI 9-1 a 9-2 LL
ACI 9-1 a 9.2 ST 1.700
1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4" Factor 1.400
1.700 ACI 9-3 Dead Load Factor 1.400 UBC 1921.2.7"O.Q Factor 0.900
ACI 9-3 Short Term Factor 1.400 .... seismic = ST : 1.100
(c) 198597 ENERCALC c:!mmrcakuotlW.&w lWJXO275.5, VS.O.2.1 Jun-1997
' Firouzi Consulting Engineers, Inc ntk : Ld 103 Rddgn Job X W244
16969 Bernard0 Center Drive f201
San Diego, California 92128
Phone: (619) 4864227
Fax: (619) 485-6201
DS.Jnr: D.1.: DuuipUon :
scope :
L General Footing Analysis & Design
Description Continuous Footings
Along Line 0
Allowable Soil Bearing
Short Term Increase
2,400.0 psf Dlrnenslons ...
1.330 in Width along X-X Axis 3.250 R
Base Pedistal Height 0.000 in Length along Y-Y Axis 1.000 R
Seismic Zone 4 Footing Thickness 15.00 in
Overburden Weight
Live 8 Short Term Combined Col Dim. Along Y-Y Axis
fC
12.00 in
FY 60,000.0 psi
3,000.0 psi
Concrete Weight 145.00 pd Min Steel Rebar Cover
0.00 psf Col Dim. Along X-X Axis 12.00 in
0.0014
3.00 in I Loads 1 Applied Vertical Load ... Deed Load 5.223 k ... ecc along X-X Axis 0.000 in
Live Load 1.500 k Short Term Load k
... ecc along Y-Y Axis 0,000 in
Applied Moment....
Dead Load
Live Load
Short Term
Applied Shears...
Dead Load
Live Load
Sholt Term
Creates Rotation about Y-Y Axlp
(pressures @D left 8 right)
k-fl
k-ft
Creates Rotation about Y-Y Axis
(pressures @ left 8 right)
k-ft
k
k
k
Creates Rot etion about X-X Axis
(pressures @top 8 bot)
k-ft k-R k-R
Creates Rotation about X-X Axis
(pressures @top 8 bot)
k
k
k .. ..
Footing Design 01 1 3.25 fl x 1.00 fl Footing, 15.0 in Thick, w/12.00 x 12.00 in column 0.0 in high
Max Soil Pressure QL& DL+LI +ST 2,249.9 2,249.9 psf Max Mu/Phi 2.131 k-ft A&&& Allowable
Allowable 2,400.0 3,lW.O psf Required Steel Area 0.202 in2
"Y' Ecc, of Resultant
"X' Ecc, of Resultant 0.000 in 0.000 in Vu : 1-Way 3.314 93.113psi
0.000 in 0.000 in Vu : 2-Way 3.261 186.228 psi
X-X Min. Stability Ratio ggg,ooo:1
Y-Y Min. Stability Ratio ggg.000 :1 1.500 :l
! (C) 198597 ENERCALC c:\enMcakuo1lo6..m KW-0807.755, V5.0.2,l Jun-IW7
' Firouzi Consulting Engineers, Inc
San Diego, California 92128
16959 Bemardo Center Drive X201
Title : Lot 108 Rdaign Job# 08244 DuJnr: Dercrlption : Date:
LFooting Design
Shear Forces W"
Two-way Shear 3.26 3.11 1.55 psi 186.23 psi
Vn Phi
One-way Shea rs...
Vu/Phi @ Lett 3.31 3.10 1.59
Vu/Phi @ Right 3.31 1.59 93.11 psi
Q3.11 psi
Vu/Phi @Top
3.10
0.00 0.00
VulPhi Bottom
0.00 93.11 psi
0.00 0.00 0.00 93.11 psi
Moments " AS ReQ'd AGE3 5L Mu/Phi @ Lett 2.13 2.03 1.02 k-R 14.8 psi 0.20 in2
Mu/Phi 6 Right 2.13 2.03
Mu/Phi @Top 0.00
1.02
0.00
14.8 0.20
0.00
MulPhi @ Bottom
0.0 0.02
0.00 0.00 0.00 0.0 0.02
Service Load Soil Pressures Lett
DL + LL 2,249.87 2,249.87
Right TOP
2.249.87
Bottom
2,249.87 psf
DL+LL+ST 2,249.87 2,249.87 2,249.87 2,249.87 psf
3,288.27
3,149.81
3,288.27 3,288.27
3.149.81
3,288.27 psf
3,149.81
1,809.49 1,609.49 1,609.49
3,149.81 pd
1,609.49 psf
Factored Load Soil Pressures
ACI Eq. 9-1
ACi Eq. 9-2
ACI Eq. 9-3 I ACI Facton (per ACI. epplied internally to entered loads) 1 ACi 9-1 8 9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4" Factor 1.400
ACi 9-1 8 9-2 LL 1.700
ACI 9-1 a 9-2 ST 1.700 ACi 9-3 Dead Load Factor 1.400 UBC 1921.2.7"O.V' Factor 0,900
ACI 9-3 Short Term Factor 1.400 .... seismic = ST *: 1.100
(c) 198397 ENERCALC c:~rcalcuotl08.sm Kw"755, V5.0.2.1.Jun-1987
. Firouzi Consulting Engineers, Inc
16959 Bernard0 Center Drive #201
1 San Diego, California 92128 i 1 Fax: (619) 4854201 I ! Square Footing Design
Phone: (619) 4854227 oeop :
I General Information
Description Total Load e 78.6 kips
Dead Load
Live Load Short Term Load 0.000 # of Bars 7
Seismic Zone 4 Bar Sue 5 Overburden Weight 0.000 psf Rebar Cover 3.250 Concrete Weight 145.00 pcf rc 3,000.0 psi LL 8 ST Act Seperately FY 60,000.0 psi Load Duration Factor 1.330 Allowable Soil Bearing 2,800.00 psf Column Dimension 6.00 in
42.000 k Footing Dimension 36.600 k Thickness 6.000 R 24.00 in
I General 1
Rebar Requirement Actual Rebar "d" depth used 20OlFy
20.438 in
0.0033 As to USE per foot of Width 0.343 in2 Total As Req'd As Req'd by Analysis 2.060 in2 0.0005 in2 Mln. Relnf % to Req'd 0.0014 % Min Allow % Reinf 0.0014
6.00fl square x 24.0111 thick with 7- #5 bars
Allow Static Soil Pressure Max. Static Soil Pressure 2.473.33 psf Actual 1-Way Sheer
2,800.00 psf Allow. 1-Way Shear 17.41 psi 109.54 psi
Allow Short Term Soil Pressure 3,724.00 psf Max. Short Term Soil Pressure 1,456.67 psf Actual 2-Way Shear 57.93 psi
Allowable 2-Way Shear 219.09 psi
Mu I Phi : Actual Mn : Capacity 14.88 k-fl
36.31 k-fl
Alternate Rebar Selections ...
11 #4's 7 #Ss 5 #ts 4 #7's 3 #ts 3 Xg's 2 #lo3
(c) 1-97 ENERCALC c:hwcakWlC8.&w Kw46on55. V5.0.2,l Jub1997
!
. Firouzi Consulting Engineers, Inc Mb: LotlOgRedesJgn Job # 98244
16959 Bemardo Center Drive #201 Dlgnr: 0.1.:
San Diego, California 92128
Phone: (619) 485-6227
0.sc.rlptlon :
: Fax: (619) 485-6201
scope :
1 i ! L Square Footing Design E57 1 General Information I
Description Total Load > 78.6 kips
Total Load < 101.4 kips
Dead Load 68.100 k Live Load 33.300 k Short Term Load 0.000
Overburden Weight Seismic Zone 4
Concrete Weight 145.00 pd LL 8 ST Act Seperately Load Duration Factor 1.330 Column Dimension 8.00 in
0.000 psf
Footing Dimension Thickness #of Bars 24.00 in
6 Bar Size 6 Rebar Cover 3.250 3,000.0 psi
Allowable Soil Bearing 2,800.00 psf 60,000.0 psi
7.000 rt
rc
FY
LGeneral I
Rebar Requirement Actual Rebar “d“ depth used 2OO/Fy 20.375 in As to USE per foot of Width 0.342 in2
As Req’d by Analysis 0.0033 Total As Req’d 0.0007 in2 2.396 in2 Min Allow % Reinf Min. Reinf % to Rea’d 0.0014 % 0.0014
Footing OK
7.00fl square x 24.0in thick with 6- #6 bars
Max. Static Soil Pressure 2,359.39 psf Allow Static Soil Pressure 2,800.00 psf Actual %Way Shear Allow. 1-Way Shear 24.78 psi 109.54 psi
Max. Short Term Soil Pressure 1,679.80 psf Allow Short Term Soil Pressure 3,724.00 psf Actual 2-Way Shear 77.45 psi Allowable 2-Way Shear 219.09 DSi
Mu I Phi : Actual
Mn : Capacity
1
!
(C) 1-97 ENERCALC c:”lOg.ecw KWo6M755. V5.0.2,l JwlXl7
!
. Firouzi Consulting Engineers, Inc
16959 Bemardo Center Drive #201
San Diego, California 92128
Phone: (619) 4854227
Fax: (619) 4854201
W: LotlCSRedsrlgn Dsgnr: kdpUon :
Job I 98244 Date:
scope :
Square Footing Design
[ General Information
Deacrlptlon Total Load > 102 kips
Total Load < 147 kips
Dead Load 77.200 k Live Load Short Term Load 89,800 k 0.000
Overburden Weight Seismic Zone
0.000 psf 4
Concrete Weight LL 8 ST Act Seperately 145.00 pcf
Load Duration Factor 1.330
Thickness Footing Dimension 24.00 in 8.000 ft
# of Bars 8 Bar Size 8 Rebar Cover
CC
3.250 3,000.0 psi
FY Allowable Soil Bearlng 2,800.00 psf 60,000.0 psi
Column Dimension i.OO in I General 1 Rebar Requlrement Actual Rebar "d depth used 20.375 in As to USE per foot of Width 0.351 in2 20OlFy As Req'd by Analysis 2.808 in2
Min. Reinf % to Req'd 0.0014 %
0.0033 Total As Req'd 0.0011 in2 Min Allow % Reinf 0.0014
Footing OK
8.00fl square x 24.0in thick with 6- #8 ban
Max. Static Soil Pressure Allow Static Soil Pressure 2,586.87 psf Actual 1-Way Shear 2,800.00 psf 37.41 psi Allow. 1-Way Shear 109.54 psi
Allow Short Term Soil Pressure 3,724.00 psf Max. Short Term Soil Pressure 1,496.25 psf Actual 2-Way Shear
Allowable 2-Way Shear 219.09 psi 117.34 psi
Mu I Phi : Actual Mn : Capacity 29.49 k-ft 33.08 k-ft
Alternate Rebar Selections ... 15 #4's 10 #Ss 7 #E's 5 #7's 4 #8's 3 #9s 3 #lo's
I
. Firourl Consulting Engineers, Inc
16959 Bemardo Center Drive #201
San Diego, California 92128
Phone: (619) 485-6227
Fax: (619) 485-6201 &op :
Square Footing Design
- . . . . . " . . . . - . . . "" -. . I
Description Total Load > 147 kips Total Load < 182 kips
Dead Load 111.500k Footing Dimension
Live Load 8.750 R
Short Term Load Thickness 24.00 in # of Barn 7
Seismic Zone 4 Bar Sua 7 Overburden Weight 0.000 psf Rabar Cover 3.250 Concrete Weight 145.00 pcf fC LL 8 ST Act Seperataly
3,000.0 psi
Load Duration Factor 1.330 Allowable Soil Bearing 2,800.00 psf Column Dimension 8.00 in
69.800 k 0.000
FY 60,000.0 psi
Rebar Reauirement Actual Rebar "d" depth used 20.313 in 20OlFv 0.0033
As Riq'd by Analysis 0.0013 In2 Min. Reinf % to Req'd 0.0018 %
8.75R square x 24.0in thick with 7- #7 bars
Allow Static Soil Pressure Max Static Soil Pressure 2,658.00 psf 2,800.00 psf
As to USE per foot of Width Total As Raq'd Min Allow % Reinf
0.434 in2 3.798 in2 0.0014
Footing OK
Actual 1-Way Shear Allow. 1-Way Shear 45.29 psi 109.54 psi
Max. Short Term Soil Pressure 1,746.33 psf Allow Short Term Soil Pressure 3,724.00 psf Actual 2-Way Shear Allowable 2-Way Shear 219.09 DSi
145.04 psi
Mu I Phi : Actual Mn : Capacity
Alternate Rabar Selections ... 36.25 k-R 47.62 k-R 19 X4's 13 t5's 9 #6's 7 xrs 5 #as 4 #Qs 3
(C) 198397 ENERCALC c:bnercakbtl06.w KW-OW2755, V5.0.2,l Jun-1097
SmithConsu ItingArchitects
September 28, 1999
Tim Phillips
2075 Las Palmas Drive
Carlsbad, California 92009
RE: 1635 FARADAY AVENUE
Dear Tim,
CITY OF CARLSBAD - BUILDING INSPECTIONS
It has come to my attention that questions have arisen regarding fire rating of the
elevator shaft enclosure top at the project referenced above. The following is an
explanation.
The Tenant Improvement drawings indicate an elevator located in a non-rated lobby,
serving Two floors with a penetration through only One (1) floor. Also indicated are shaft
walls to be constructed per 'Wall Type 'C' - One Hour Partition Wall' to consist of 6, 24
gauge metal studs at 16 O.C. with 518" type 'x' gypsum board each side.
Per 1997 UBC Section 711.2, rated enclosures are not required to be enclosed at the
top, if the shaft extends to or through the underside of the roof sheathing, deck or slab.
Furthermore, 1997 UBC Section 711.3, allows a Special Provision, wherein openings
that penetrate only one floor and are not connected with openings communicating with
other stories or basements need not be enclosed.
Please contact me should you require additional information or wish to discuss further.
Respectfully,
Andrew Tarango
ARTlart
Cc: Bruce Smits, Lusardi Construction
Attachment
709.7
4 7N.3
1997 UNIFORM BUILDING CODE
I be confirmed that the fire-resistive integrity of the wall is main-
tained in accordance with UBC Standard 7-1.
709.8 Joints. The protection of joints shall comply with the re-
quirements of Section 706.
SECTION 710 - FLOOR CEILINGS OR
ROOF CEILINGS
710.1 General. Fire-resistive floors, floor-ceiling or roof- ceiling assemblies shall be assumed to have the fire-resistance rat- ings set forth in Table 7-C. When materials are incorporated into
an otherwise fire-resistive assembly that may change the capacity
for heat dissipation, fire test results or other substantiating data shall be made available to the building official to show that the re- quired fire-resistive time period is not reduced.
resistive floor-ceiling or roof-ceiling assemblies is not adequate to Where the weight of lay-in ceiling panels used as part of fire-
resist an upward force of 1 pound per square foot (0.048 kN/m2),
#ire holddowns or other approved devices shall be installed above
rhe panels to prevent vertical displacement under such upward
force.
710.2 Through Penetrations.
710.2.1 General. Through penetrations of fire-resistive horizon- tal assemblies shall be enclosed in fire-resistive shaft enclosures in accordance with Section 711.1 or shall comply with Section
710.2.2 or 710.2.3.
vents, concrete, or masonry pCWfraling items that penetrate a single
EXCEPTIONS: 1. Steel, ferrous or copper conduits, pipes, tubes,
fire-rakd floor assembly where the annular space is protected with materials that prevenl the passage of flame and hot gases sufficienl to
ignite cotton waste when subjected to UBC Standard 7-1 lime-temper-
ature fire conditions under a minimum positive pressure differential of
0.01 inch of water column (2.5 Pa) at the location of the penetration far
penetrated. Penetrating items with a maximum 6-inch (152 mm) nami-
the time pcriod equivalent to the fire-resistive rating of the construction
nal diameter shall not be limiled to the penetration of a single-fire-re-
sistive floor aascmbly, provided lhal thc area of the penetration does no1
exceed 144 square inches in any 100 square feet (100 000 mmZ in
10 m2) of floor area.
2. Penetrations in a single concrete floor by sleel, ferrous or copper
conduits, pipes, lubes and vents with a maximum 6-inch (152 mm)
nominal diameter provided concrele, grout or mortar is installed thc
full thickness of the tloor or the thickness required Io maintain the fire-
mm) nominal diametcr shall not he limiled to the penetration of a single
resistive rating. The penetrating items with a maximum 6-inch (152
concrele floor, pruvidcd that the area of tbc penetration does not exceed
144 square inches (Y2 903 mm’).
3. Electrical outlet boxes of any material are permitted provided that
such boxes are tested for use in fire-rcsistive assemblies and installed
in accordance wilh the tested assembly.
710.2.2 Fire-rated assemblies. Penetrations shall be installed as tested in the approved UBC Standard 7-1.
710.2.3 penetration firestop system. Penetration shall be pro- tected by an approved penetration firestop system installed as tested in accordance with UBC Standard 7-5. The system shall
than the required rating of the floor penetrated.
have an F rating and a T rating of not less than one hour but not less
cavity of a wll do not require il T rating.
EXCEFTION: Flour penetrations contained and located within the
710.3 Membrane Penetrations. Penetrations of membranes that are part of a fire-resistive horizontal assembly shall comply
with Section 710.2.
per conduits, electrical outlet boxes, pipes, tubes, vents, concrete, or EXCEPTIONS: 1. hlembrsnr penetrations of steel, ferrous or cop-
masonry penetrating items where the annular space is protected in
accordance with Section 709.6 or 710.2 or is protected to prevenl the
free passage of flame and the products of combustion. Such penetra-
tions shall not exceed an aggregale area of I00 square inches in any 100
square feet (694 mmzlm2) of ceiling area in assemblies tested without
penetrations.
are permitted, provided that such boxes are tested for use in fire-resis-
2. Membrane penetrations far eleclrical outlet boxes of any material
Live assemblies and installed in accordance with the tested assembly.
3. The annular space created by the penelration of a fire sprinkler
shall be permitted lo be unprotected. provided such space is covered by
a metal escutcheon plate.
710.4 Roofs. Fire-resistive roofs may have unprotected open-
ings. See Chapter 24 for skylight construction.
710.5 Wiring in Plenums. Wiring in plenums shall comply with the Mechanical Code.
710.6 Joints. The protection of joints in fire-resistive floors and roofs shall comply with the requirements of Section 706. I
SECTION 711 -SHAFT ENCLOSURES
711.1 General. Openings through floors shall be enclosed in a
shaft enclosure of fire-resistive construction having the time peri- od set forth in Table 6-A for “shaft enclosures” except as permitted in Sections 711.3, 711.5 and 711.6. See also Section 304.6 for
shafts in Group B Occupancies, Section 306.6 for shafts in Group F Occupancies, Sections 307.6 and 307.1 1.2.3 for shafts in Group
and Section 311.6 for shafts in Group S Occupancies.
H Occupancies, Section 309.6 for shafts in Group M Occupancies
711.2 Extent of Enclosures. Shaft enclosures shall extend from the lowest floor opening through successive floor openings and
shall be enclosed at the top and bottom.
the roof sheathing. deck or slab need not be enclosed at the top. 4 EXCEPTIONS: 1. Shafts extending through or to the underside of
2. Shafts need no1 be encloscd $11 thc bottom when protected by fire
dampers conforming Io approved rccognirrd standards, installed at thc
lowest floor level within thc shaft enclosure.
Shaft enclosures shall be constructed to continuously maintain
the required fire-resistive integrity.
711.3 Special Provision. In other than Group I Occupancies, openings that penetrate only one floor and are not connected with openings communicating with other stories or basements and that are not concealed within building construction assemblies need
not be enclosed.
Section 1005.3.3. Exit enclosures shall conform to the applicable provisions of
cies, gas vents, ducts, piping and factory-built chimneys that ex-
In one- and two-story buildings other than Group 1 Occupan-
tend through not more than two fioors need not be enclosed, provided the openings around the penetrations are firestopped at
each floor.
EXCEPTION: BW gas vents installed in accordance wilh their
Gas vents and factory-built chimneys shall be protected as re- quired by the Mechanical Code.
Walls containing gas vents or noncombustible piping that pass through three floors or less need not provide the fire-resistance rat- ing specified in Table 6-A for “shaft enclosures,” provided the an-
nular space around the vents or piping is filled at each floor or ceiling with noncombustible materials.
EXCEPTION BW gar vents installed in accordance with their
Openings made through a floor for penetrations such as cables,
cable trays, conduit, pipes or tubing that are protected with ap- proved through-penetration fire stops to provide the same degree
listing.
listing.
1-72
Visual Selection Performance Selection
1 .?. c i .I. c
180 TWhLine Il-B(uI-CEILINGS I 3
09/62/1999 18:32 7607399393 GR&NI ESCONDIDO PAGE 61
Suprafine
9/16 exposed tee systems
Phvsical Data
yI)*l mlasw"
b
/ /
,'
Color Selection