HomeMy WebLinkAbout1640 BRADY CIR; ; CB101689; Permit\ 10-01-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Electrical Permit Permit No: CB101689 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Reference #: PC#: Project Title: 1640 BRADY CRCBAD ELEC 2054401900 Lot#: KOVALEV: ROOF MOUNT PV SYSTEM 16 PANELS Status: ISSUED Applied: 09/14/2010 Entered By: JMA Plan Approved: 10/01/2010 Issued: 10/01/2010 Inspect Area: Applicant: NATURAL ENERGY TED MOUNT 147 S VINEWOOD ST 92029 760 743-6400 Owner: KOVALEV VLADIMIR 1640 BRADY CIR CARLSBAD CA 92008 Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AM!* Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees $10.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $110.00 $0.00 TOTAL PERMIT FEES $120.00 Total Fees:$120.00 Total Payments To Date:$120.00 Balance Due;$0.00 Inspector: FINAL APPROVAL Date: '&Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. 0 ••• -it CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax: 760-602-8558 www.carlsbadca.gov Plan Check No. Est. Value Plan Ck. Deposit Date <\[ 14 [(£> SUITE#/SPACE#/UNIT# # BATHROOMS I TENANT BUSINESS NAME#OF UNITS I # BEDROOMS CONSTR. TYPE OCC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) FIREPLACE YES D # AIR CONDITIONING YES O -jNO D FIRE SPRINKLERS YES D NO D CONTACT NAME (H Different Font App, CONTRACTOR BUS. NAME ARCH/DESIGNER NAME & ADDRESS civil penalty of not more than five hundred dollars ($500)). structure, prior to its issuance, also requires the, commending with Section 7000 of Division 3 of the any applicant for a permit subjects the applicant to a Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: G I have and will maintain a certificate if consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. O I have and will maintain workeps^ cwnpensation^s requirea^y Section 3700gf tbeLabor Code, for the performance of thedwork fpuivhieh ftjsparmJLJsJssued. My workers' compensation insurance carrier and policy number are: Insurance Co. .^ /^y i/ ^^ ' J^t/V //Cy\^ Policy No. Ls(.s*e£±~^ (.tyT~^ Expiration Date This section need not be completed if the permit is for one hundi&ti dollars ($100) or less. LD Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall no/employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers^emnpensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.000), in addition to the cost of compensation, damagjeS^Moyided for in Section 3706 of the Labor o6de, interest and attorney's fees. CONTRACTOR SIGNATURE ENT DATE / hereby affirm that I am exempt from Contractor's License Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. D Yes O No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide-the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicatedhfnclude name / address / phone / type of work): ^PROPERTY OWNER SIGNATURE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? n Yes D No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O Yes O No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? a Yes a No IF ANY OF THE ANSWERS ARE YES, / EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certify that I have read the application and state that the above information is correct and that the information on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby aufliorize representative of the City of Carisbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMfT. OSHA: An OSHA permit is required for excavations over 5'u" deep and demolition or construction of structures over3s3hes in height. EXPIRATION: Every permit issued by the Building Officjajfcnder the provisions of this Code shall expire by limitation a^fl become null and void if Ihe building or work authorized by such permit is not commenced within 180 days from the date of such permit or if theM™dwwork authorized by such permit is suspended or abandons at any time after the work is commenced for a period of 180/lays (Sectbn/106.4.4 Uniform Building Code). ^^APPLICANT'S SIGNATURE DATE City of Carlsbad Bldg Inspection Request For: 10/18/2010 Permit* CB101689 Title: KOVALEV: ROOF MOUNT PV SYSTEM Description: 16 PANELS Inspector Assignment: RB 1640 BRADY CR Lot: Type: ELEC Sub Type: Job Address: Suite: Location: APPLICANT NATURAL ENERGY Owner: KOVALEVVLADIMIR Remarks: RING THE BELL H.O. WILL OPEN Phone: 7607436400 Inspector: Total Time: CD Description 39 Final Electrical Act ^Comments Requested By: LARRY Entered By: CHRISTINE Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date Description 10/15/2010 39 Final Electrical 10/07/2010 34 Rough Electric 10/07/2010 39 Final Electrical 10/05/2010 39 Final Electrical Act Insp Comments CA TP CO RB NO ACCESS CO RB CO RB SEE NOTICE ATTACHED City of Carlsbad Bldg Inspection Request For: 10/05/2010 Permit* CB101689 Title: KOVALEV: ROOF MOUNT PV SYSTEM Description: 16 PANELS Inspector Assignment: 1640 BRADY CR Lot: Type: ELEC Sub Type: Job Address: Suite: Location: APPLICANT NATURAL ENERGY Owner: KOVALEVVLADIMIR Remarks: Phone: 7607436400 Inspector: Total Time: CD Description 39 Final Electrical Act Comments Requested By: LARRY LIPTAK Entered By: CHRISTINE Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date Description Act Insp Comments NOTICECITY OF CARLSBAD (760)602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE /O * f "" /& TIME _ _____ LOCATION PERMIT NO. _ - t*r '-/. FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION, CONTACT . YES PHONE BUILDING INSPECTOR.. .. - CODE ENFORCEMENT OFFICER PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 6 ADDRESS {,40 DATE RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$17,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER ^ PLANNER DATE ENGINE DATE H:\Development Servfces\Coitespondence\Ontjveros\fbr p(anctiecklng\BUILDING PLANCHECK CKLIST FORM - PLANNING ENGINERING APPROVALS.doCX PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 10-1689 DATE 9/14/10 ADDRESS 1640 Brady Circle RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE 9-H-/0 DATE H:\ADMIN\COUNTER/PLANNING/ENG[NEERING APPROVALS Check a License - Contractors State License Board Page 1 of 1 Department of Consumer Affairs Contractors State Li Contractor's License Detail - License # 481870 oard DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. ••*>> CSLB complaint disclosure is restricted by law (B&P 7124.6) If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. •* Per B&P2Q1HZ., only construction related civil judgments reported to the CSLB are disclosed. •* Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. ••» Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. License Number 481870 Extract Date: 10/1/2010 DBA NATURAL ENERGY Business Information 147 S VINEWOOD ST ESCONDIDO, CA 92029 Entity: __§_9l§^wUfi[ShJP Jssue_Date_ '_ 10/?8/1985_ Expire Date 10/31/201 License status This license is current and active. All information below should be reviewed. CLASS DESCRIPTION Classifications: B GENERAL BUILDING CONTRACTOR C46 SOLAR _ _ _ __ CONTRACTOR'S BOND This license filed Contractor's Bond number 138196 in the amount of $12,500 with the bonding company °" . AMERICAN CONTRACTORS INDEMNITY COMPANY. Effective Date: 01/01/2007 Contractor's Bonding History. _ _ This license has workers compensation insurance with the STATE COMPENSATION INSUBANCE_FUND Policy Number:713-0025795 Workers' Compensation: _«...,,Effective Date: 01/01/2008 Expire Date: 01/01/2011 Workers' Compensation History Personnel listed on this license (current or disassociated) are listed on other licenses. Cond.iiiQ.Ds..oLUse | PrjyjcyJBQljcy Copyright © 2010 State of California https://www2.cslb.ca.gov/OnlineServices/CheckLicenseII/LicenseDetail.aspx?LicNum=4... 10/01/2010 PROPOSED SCOPE OF WORK : • 16 ROOF MOUNTED PHOTOVOLTAIC MODULES • (16) ENPHASE MICROINVERTERS • 3.04 kW AC OUTPUT (TOTAL SYSTEM SIZE) SHEET INDEX: El - SOLAR PHOTOVOLTAIC SYSTEM PL<gT PLAN E2 - SOLAR PHOTOVOLTAIC 1 - LINE \4 ! E3 - SOLAR PHOTOVOLTAIC PLAQUE PL NOTE: SUPPORT PV ARRAY'S AT MAXIMUM SPACING OF 4' 0". MOUNT PV PANELS 6" ABOVE ROOF." ( U.N.O.) Property Line N...5ft. Setback 70ft. Setback (16)PV PANELS (288 Sq. Ft.) 200 Amp Panel PV BREAKER 5ft. ..Setback. GENERAL NOTES: 1. This project shall comply with the 2007 California Building Code, which adopts the 2006 IBC, 2006 UMC, 2006 UPC and the 2005 NEC. 2. Mount array's to the RoofTrac system per the manufacturer's requirements. PV Panels will be approximately 6" above the lowest portion of the tile. 3. Roof coverings shall be designed, installed and maintained in accordance with this code and the approved manufacturer's instructions such that the roof covering shall serve to protect the building or structure. CBC 1503. 4. # 10 USE-2 in free air wire used between modules and J-box. 5. #8 Bare Copper wire used to ground all modules. 6. Provide 5/16" x 3-1/2" lag bolt with 2-1/2" min. embedment into roof frame. SOLAR PHOTOVOLTAIC SYSTEM PLOT PLAN DATE: September 10, 2010 Contact: Ted Mount (760)743-6400 CA LIC #481870 NATURAL ENERGY 147 South Vinewood Street Escondido, CA 92029 (760)743-6400 (760)743-0871 Fax PROJECT: Vladimir Kovalev 1640 Brady Circle Carlsbad, CA. 92007 Cross street: Magnolia Ave. Parcel # 205-440-19-00 E1 CA/oi m . g UJ < 35 N cr.u S DATE: SeptemberSOLAR PHOTOVOLTE> « O .2 1? STo •- * 1>S •- E-O E«S di40lsVla16Ca47 South Vinewood StreetEscondido, CA 92029(760)743-6400(760)743-0871 FaxContact:Ted Mount(760)743-6400CA C-46 LIC #85340 200 Amp Panel PV BREAKER 1640 BRADY CIRCLE SOLAR PHOTOVOLTAIC PLAQUE PLAN DATE SENT FOR PLAQUE: Contact: Ted Mount (760)743-6400 CA. C-46 LIC #481870 NATURAL ENERGY 147 South Vinewood Street Escondido, CA 92029 (760)743-6400 (760)743-0871 Fax PROJECT: Vladimir Kovalev 1640 Brady Circle Carlsbad, CA. 92007 E3 Edition: June 2010 ! i i ! I i i I • I ! '• } Length 65.94 in (1675 mm) Width 39.41 in (1001 mm) Height 1.34 in (34 mm) Frame Aluminum Weight 48.5 Ibs (22 kg) SW 240 mono High-quality, high performance, and high reliability - the Sunmodule Plus® is designed and built for long-term yield stability and ease of use. Every module is factory flashed at standard test conditions (STC) to determine the power output and then sorted in 5 watt increments. Only modules with a flashed powerthat isgreaterthan orequaltothe nameplate rated power are delivered. Flash report data is provided with every order. The proven design of the patented low profile Sunbox junction box, has been installed on over 4,000,000 modules. Integrated by-pass diodes and sealed welded • connections ensure reliability and eliminate failures resulting from exposure to the elements. The molded fins on the exterior housing dissipate heat quickly to ensure high reliability and long life. The patented box channel frame design provides extraordinary stiffness in bending and torsion. The laminate with 4 mm glass is set deep in the frame channel and secured with precision applied adhesive. The frame is assembled by press fit to maximize strength and longevity. The result is an extremely robust package that can be mounted in any orientation and can withstand static loads of up to 113 psf. SolarWorld provides a 5-year workmanship warranty* and 25-year linear perfor- mance guarantee* *See warranty statement for details. www.solarworld-usa.com We turn sunlight into power. Sunmodule?" SW 240 mono Performance under standard test conditions (STC*) Maximum power Pmas Open circuit voltage Voe Maximum power point voltage . Vmff Short circuit current lsc Maximum power point current lm 'STC: 1000W/M2,25°C, AM 1.5 Performance at 800 W/m2, NOCT, AM 1.5 SW240 240 Wp 37.6V 30.6V 8.22 A 7.87 A Maximum power Open circuit voltage Maximum power point voltage Short circuit current Maximum power point current SW240 175 Wp 34.2V 27.9V 6.63 A 630 A Minor reduction in efficiency under partial load conditions at 25°C: at 220 W/m2,95% (+/- 3%) of the STC efficiency (1000 W/rrf) is achieved. Component materials Cells per module Cell type Cell dimensions Thermal characteristics NOCT TCIK TCVo<TC ?„„ 60 monocrystalline silicon 156x156 mm2 47°C 0.042 %/°C -0.33 %/°C -0.45 %/°C System integration parameters Maximum system voltage SCII 1000 VDC Maximum system voltage USA NEC 600 VDC Maximum series fuse rating 15 A Maximum reverse current Dp not apply external voltages larger than Voc to the module Additional data PTC rating Junction box Connector Module efficiency Power tolerance* 213.2 W IP 65 MC type 4 14.3% +/- 3 % Front 39.41 (1001) > ' Side 1.34(34) 2 rN rN rHrNrN o "o~o m ^1-11.32 (287.5Rear 37.80 (960)37.40 (950)_ H h —a _0 - 00.26(6.6) -00.35(9) - 0 0.26 (6.6) Construction 1] Front: tempered glass 2] Crystalline solar cells embedded in EVA (ethylene-vinyl-acetate) 3] Backsheet Dimensions: inches (mm) IEC 61215 Safety class II SolarWorld AC reserves the right to makesoecification changes without notice. Sunmodules are manufactured in ISO 9001:2000 certified facilities. This data sheet complies with the requirements of EN 50380.Made in USA ENPHASE MICROINVERTER M190 The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the microinverter, the Envoy Communications Gateway, and the web-based Enlighten monitoring and analysis website. PRODUCTIVE RELIABLE SMART L - Maximum energy production - Resilient to dust, debris and shading - Performance monitoring per module - MTBF of 331 years - System availability greater than 99.8% - No single point of system failure - Quick & simple design, installation and management - 24/7 monitoring and analysis SI us MICROINVERTER TECHNICAL DATA Input Data (DC) Recommended input power (STC) Maximum input DC voltage Peak power tracking voltage Min./Max. start voltage Max. DC short circuit current Max. input current Output Data (AC) Maximum output power Nominal output current Nominal voltage/range Extended voltage/range Nominal frequency/range Extended frequency/range Power factor Maximum units per branch Efficiency Peak inverter efficiency CEC weighted efficiency Nominal MPP tracking Mechanical Data Operating temperature range Nighttime power consumption Dimensions (WxHxD) Weight Cooling Enclosure environmental rating Features Communication Warranty Compliance 60 and 72 Cell Modules M190-72-208-S12/3 M190-72-208-S12/3-NA (Ontario) 230W 56V 22V-40V 28V/54V 12A 10A 190W 920mA 208V/183V-229V 208V/179V-232V 60.0/59,3-60.5 60.0/59.2-60.6 >0.95 21 95.5% 95.0% 99.6% M190-72-240-S12/3 Ml 90-72-240-S12/3-NA (Ontario) 230W 56V 22V-40V 28V/54V 12A 10A 190W 800mA 240V/211V-264V 240V/206V-269V 60.0/59.3-60.5 60.0/59.2-60.6 >0.95 15 95.5% 95.0% 99.6% -40°C to +65°C -40°C to +65°C 30mW 30mW 8" x 5.25" x 1.25" 4.4 Ibs Natural Convection - No Fans Outdoor-NEMA 6 Powerline 15 Years UL1741/IEEE1547 FCC Part 15 Class B Enphase Energy, Inc. 201 1st Street, Suite 300, Petaluma, CA 94952 877 797 4743 enphaseenergy.com 142-00005 REV 05 Printed on 100 percent recycled paper. ENERGY Sample Wiring Diagram - M190-72-240-Slx, M210-84-240-S12 3 -•} I SS..'" ? I I = 3 Jill!HiSlI Page 24 Copyright Enphase Energy Inc. 2009 141-00007 REV 3 RoofTmcLfe. PV MOUNTING SYSTEM COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products BP/TILETRAC MOUNT COMPONENTS SLIDING CARRIAGE 3/8'X1-1/2" THREADED HEX STUD FOR COM- POSITION ROOFS 5/16" X 3' LAG BOLT TILE TRAC ATTACHMENT BASE 3/8" X 1-1/2° THREADED HEX HEAD STUDS 5/16" LOCK WASHER 3/8" X 6" / THREADED- STUD FOR TILE ROOF 5/16" X 2-3/4" HEX BOLT 5/16" LOCK WASHER INTER-MODULE CLAMPS QTY: 6 QTY:2 SUPPORT RAIL 130" LONG NOTE: BP I.D. LINE 5/16" X 3/4" HEX BOLTS MODULE END CLAMPS QTY: 4 SETS 5/16" THREAD SLIDING INSERT CLAMP QTY: 10 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products INSTALLATION OF THE MODULES OVER THE SUPPORT RAILS COPYRIGHT PROFESSIONAL SOUR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products INSTALLATION OF TILE TRAC® STEP1 STEP 2 STEP 1: MARK A REFERENCE LINE ACROSS THE TILES IN THE VACINITY OF THE ROOF RAFTER. REMOVE THE ROOF TILE BY PUSHING AND PULLING ON THE TILE: IT IS HELD IN PLACE BY A SMALL NAIL. LIFT WITH A FLAT NAIL BAR IF NECESSARY. STEPS STEP 2: LOCATE THE CENTER OF THE RAFTER BY TAPPING WITH A HAMMER OR USING AN ELECTRONIC STUD SENSOR. AFTER' LOCATING THE CENTER OF THE RAFTER DRILL A 3/16" PILOT HOLE IN LINE WITH THE CHALK LINE. STEP 4 STEP 3: INSTALL THE LOWER TRACK ASSEMBLY USING A 5/16" LAG BOLT AND SPECIAL WASHER. PLACE SEALANT AROUND BOLT AND LOWER TRACK, BE SURE TO SEAL THE NAIL HOLE FROM THF Til F YOU RFMOVFD STEPS STEP 4: AFTER INSTALLING THE LOWER TRACK, SLIDE THE UPPER MOVABLE CARRIAGE ASSEMBLY INTO POSITION AT THE HIGH POINT OF THE TILE. STEPS STEP 5: REPLACE THE TILE AND DRILL A 3/8" HOLE USING A MASONRY DRILL, INTERSECTING THE REFERENCE LINE AND THE HIGH POINT OF THE TILE. STEP? BIND STEP 6: INSERT THE THREADED SHAFT THROUGH THE HOLE IN THE ROOF TILE, LOCATING THE UPPER TILE TRAC® CARRIAGE. IF NECESSARY, PICK UP THE ROOF TILE TO ASSIST IN STARTING THE THREADED SHAFT. INSERT AND LOCK TWO 3/8" NUTS ON THE THREADED SHAFT AND TIGHTEN DOWN USING A 9/16" WRENCH. STEPS REFER TO PAGE SIX FOR INSTALLATION OF THE SUPPORT RAIL. STEP 7: INSERT AND LOCK TWO 3/8" NUTS ON THE THREADED SHAFT AND TIGHTEN DOWN USING A 9/16" WRENCH. STEP 8: APPLY SEALANT AROUND THE THREADED SHAFT COMPRESSING THE SEALANT WITH THE ENCLOSED 3/8" WASHER. COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products PV PANELS 200 Amp Panel PV BREAKER 1640 BRADY CIRCLE GENERAL NOTES: 1. Materials used for marking shall be weather resistant. UL 969 shall be used as a standard for rating(UL listing of markings is not required)' 2. Provide red background with white 3/8" high capital letters in arial non bold or similar font on reflective weather resistant material suitable for the environment ( durable adhesive materials must meet this requirement). NVERTER: "lax AC pbWef output-range; :2l'c-|fVH>i> ^ lax c»r^ntf<3^. output duTO%ff ^ISQ CEC rated effjcf^ncy: 95^, s^^1 Total rated 6utt)uC:3Cl4,Ow j> 24W SOLAR PHOTOVOLTAIC PLAQUE PLAN Contact: Ted Mount (760)743-6400 CA. C-46 LIC #481870 NATURAL ENERGY 147 South Vinewood Street Escondido, CA 92029 (760)743-6400 (760)743-0871 Fax DATE SENT FOR PLAQUE: PROJECT: Vladimir Kovalev 1640 Brady Circle Carlsbad, CA. 92007 E3 n V)a \ /ois i a &8, n u I! .( • • rV^iJ^— ~*=~*e..£3*5 «»