HomeMy WebLinkAbout1642 BRADY CIR; ; CBR2018-2044; PermitCity of
Carlsbad
Residential Permit
Print Date: 08/09/2019
Job Address: 1642 Brady Cir
Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Status:
Parcel No: 2054401900 Lot fi: Applied:
Valuation: $82,652.10 Reference #: Issued:
Occupancy Group: Construction Type: Permit
Finaled:
# Dwelling Units: 1 Bathrooms: Inspector:
Bedrooms: Orig. Plan Check #: . Final
Plan Check #: Inspection:
Project Title:
Description: GARROD: 430 SF ADDITION & CONVERT 210 SF OF GARAGE FOR A TOTAL ADU OF 640 SF
Applicant: Owner:
JUAN BARRIENTOS COOWNER GARROD PAUL T AND LAURA M
1640 Brady Cir
CARLSBAD, CA 92008
760-755-3299
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES - outside CFD
5B1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Permit No: CBR2018-2044
Closed - Finaled
08/15/2018
10/15/2018
AKrog
8/9/2019 12:24:47PM
$552.19
$386.53
$43.00
$170.00
$52.00
$80.00
$2,892.82
$4.00
$10.74
Total Fees: $4,191.28 Total Payments To Date: $4,191.28 Balance Due: $0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction.' You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
feesand capacity changes: nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to whichthe
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 1760-602-2700 1 760-602-8560 f I www.carlsbadca.gov
RESIDENTIAL
Plan Check (City of BUILDING PERMIT
__________ Est. Value
Carlsbad.APPLICATION PC Deposit
B1 Date
Job Address '(.0 't2._1 '( - --- Suite: APN:
CT/Project #: Lot #:) Fire Sprinklers: yes2r7 Air Conditioning: yes Llp
BRIEF DESCRIPTION OF WORK: 17') C.L.-( I T J
) —
j Addition/New New SF, Deck SF, Patio SF, Garage SF
Is this to create an Accessory Dwelling Unit? Yes / No New Fireplace? Yes / No, if yes how many?
Remodel: '2!I 0 SF of affected area Is the area a conversion or change of use? Yes / No
fl Pool/Spa: SF Additional Gas or Electrical Features?
j 7-c
E] Solar: KW, _Modules, Mounted, Tilt: Yes / No, RMA: Yes / No, Panel Upgrade: Yes / No,
Battery Yes / No C.c.. .9fj
o Reroof:
El Plumbing/Mechanical/Electrical Only:
°Other: QJDflVJ* 230 POC & 2 DO.
APPLICANT (PRIMARY) PROPERTY OWNER
Name: ci (JlJ 117, Name:
Address: 03 (t1-.ioo Z _'71 Address: I , -( 0 _j7,ô4X_ (Z . 0
City: Statet-Zip: gz.aD7City: StatetJh_Zip: zeoI
Phone: -2,(-0 '-7d4 Phone: /-763. q. 'çj'
Email: ie Email: %7. 0i(v'0e3 t4r.*i49L,_(.Eet -
I —'
DESIGN PROFESSIONAL
Name:
Address:
City: State:Zip:
Phone:
Email:
Architect State License:
CONTRACTOR BUSINESS
Name:
Address: 7:t9 7rDsJ 5T T).
City: State:#_Zip: lsts&
Phone: e-7-7 00
Email: zj-' to ,&1,c.. +i'o....
State License: .. Bus. License: ç' 2_'i /52
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$5001).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Build ingIcarlsbadca.gov
R-1 Paqe 1 of 2 Rev. 06/18
(OPTION A ): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensati n insurance carrier and policy number are: Insurance Co a7 Name: t3v.CL.l.IA&4t 1C it1wa .-cP
Policy No. .471'' C7 t V? 6 3 Expiration Date: / Y
0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in ition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney's fees. I I A
CONTRACTOR SIGNATURE: EGENT DATE:____________
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
O I am exempt under Section Business and Professions Code for this reason:
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 Yes 0 No
I (have / have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address I phone /
contractors' license number):
S. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):
OWNER SIGNATURE: DAGENT DATE:
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the pelormance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: Lender's Address:
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No .
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes 0 No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? E3 Yes 0 No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARLSBAD AGAINSTALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'O' deep and demolition or construction of structures over 3 stones in height.
EXPIRATION: Every permit issued by the Building Official un4QT the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 days from thetd4te of such permit or if the building or work authorized by such permit is suspended or abandoned at any time
after the work is commenced for a period of 180 days (SectirI 106.4.4 Uniform Building Code).
DATE:__________
1635 Faraday Ave Carlsbad, CA 92008 760-602-2719 Fax: 760-602-8558 Email: BuildingccarIsbadCa.gov
B-I Page 2 of 2 Rev. 06/18
APPLICANT SIGNATURE:
Permit Type: BLDG-Residential Application Date: 08/15/2018 Owner: COOWNER GARROD PAUL T AND
LAURA
Work Class: Second Dwelling Unit Issue Date: 10/15/2018 Subdivision: CARLSBAD TCT#98-12 MAGNOLIA
GARDENS
Status: Closed - Finaled Expiration Date: 01/21/2020 Address: 1642 Brady Cir
Carlsbad, CA 92008-2574
IVR Number: 13243
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary inspector Reinspection Complete
Checklist Item COMMENTS Passed
BLDG-17 Interior Lath-Drywall Yes
BLDG-18 Exterior Lath and Yes
Drywall
0712412019 07124/2019 BLDG-Final 098495.2019 Failed Michael Collins Reinspection Complete
Inspection
0810912019 08109/2019 BLDG-Fin
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Notice No
BLDG-Plumbing Final No
- BLDG-Mechanical Final• No
BLDG-Structural Final No
BLDG-Electrical Final No
100384.2019 Passed Chris Renfro Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Notice Yes
'BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final ' Yes
13
Page 3of3 August 09, 2019
Permit Type: BLDG-Residential Application Date: 08/15/2018 Owner: COOWNER GARROD PAUL T AND
LAURA
Work Class: Second Dwelling Unit Issue Date: 10/15/2018 Subdivision: CARLSBAD TCT#98-12 MAGNOLIA
GARDENS
Status: Closed - Finaled Expiration Date: 01/21/2020 Address: 1642 Brady Cir
Carlsbad, CA 92008-2574
lVR Number: 13243
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
0310612019 03105/2019 BL6G-33 Service 085284-2019 Failed Andy Krogh Reinspection Complete
Change/upgrade
Checklist item COMMENTS Passed
BLDG-Building Deficiency No SDG&E No
03107/2019 0310712019 BLDG-33 Service 085553-2019 Passed Andy Krogh Complete
Change/upgrade
03/14/2019 03/14/2019 BLDG-Il 086155-2019 Passed Andy Krogh Complete
Foundation!Ftg/Pier
s (Reber)
04/22/2019 04/22/2019 BLDG-IS 089591-2019 Passed Chris Renfro Complete
RooflReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05/30/2019 05/30/2019 BLDG-13 Shear 093361.2019 Passed Andy Krogh Complete
Panels/HD (Ok to
wrap)
BLDG-84 Rough 093180.2019 Failed Andy Krogh Reinspection Complete
Combo(14,24,34,44)
Checklist item COMMENTS Passed
BLDG-Building Deficiency Requires exterior wrapped, corrections left No
on card
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
06/10/2019 06/10/2019 BLDG-84 Rough 094311.2019 Passed Andy.Krogh Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 'es
Rough-Ducts-Dampers
06/14/2019 06/14/2019 BLDG-82 Drywall, 094789-2019 Passed Andy Krogh Complete
Exterior Lath, Gas
Test, Hot Mop
August 09, 2019 Page 2of34
Permit Type: BLDG-Residential Application Date: 08/15/2018 Owner: COOWNER GARROD PAUL T AND
LAURA
Work Class: Second Dwelling Unit Issue Date: 10/1/2018 Subdivision: CARLSBAD TCT#98-12 MAGNOLIA
GARDENS
Status: Closed - Finaled Expiration Date: 01/21/2020 Address: 1642 Brady Cir
Carlsbad, CA 92008-2574
IVR Number: 13243
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
1212712018 12/2712018 BLDG-SW-Pre-Con 079904-2018 Passed Andy Krogh Complete
Checklist Item COMMENTS Passed
• BLDG-Building Deficiency Meeting with contractor and homeowner for Yes
addition and utilities relocation
01110/2019 01/10/2019 BLDG-81 081099.2019 Passed Andy Krogh Complete
Underground
C6mbo(11,12,21,31)
Checklist Item COMMENTS Passed
BLDG-11 Foundation-Ftg-Piers Partial first pour of two walls as noted in Yes
(Reber) engineering report
BLDG-21 . . Yes
Underground-Underfloor ) Plumbing
BLDG-31 . Yes
Underground-Conduit Wring
BLDG-84 Rough 080916.2019 Failed Andy Krogh Reinspection Complete
Combo(14,24,34,44) . . .
Checklist item, COMMENTS Passed
BLDG-Building Deficiency . Wrong code No
BLDG-14 No.
Frame-Steel-Bolting-Welding
(Decks) .
BLDG-24 Rough-Topout . No
BLDG-34 Rough Electrical . No
BLDG-44 No
Rough-Ducts-Dampers
01/31/2019 01/31/2019 BLDG-lI 082696-2019 Failed Andy Krogh . Reinspection Complete
Foundation/Ftg!Pier .
S (Reber) .
• Checklist Item COMMENTS . . Passed
BLDG-Building Deficiency Incomplete I, No
BLDG-23 . 082697-2019 Failed Andy Krogh • Reinspection Complete
Gas/Test/Repairs
Checklist Item COMMENTS . Passed
BLDG-Building Deficiency Not holding pressure No
02/01/2019 02/01/2019 BLDG-23 • 082864-2019 Passed Andy Krogh Complete
Gas/Test/Repairs .
02/13/2019 02/13/2019 BLDG-33 Service •083457-2019 Cancelled Andy Krogh Reinspection Complete
Change/Upgrade . .
Checklist Item COMMENTS. Passed
BLDG-Building Deficiency . • No
August 09, 2019 . . Page lof3
V EsGil
A SAFEbuittCompany
DATE: 9/20/2018 0 ,APPLICANT
,JURIS.
JURISDICTION: CARLSBAD
PLAN CHECK #.: CBR2018-2044 SET: II
PROJECT ADDRESS: 1642 BRADY CIRCLE
PROJECT NAME: SFD NEW UNIT ADDITION FOR GARROD
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
fl The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
E The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
LI The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: JugD.Parrientos Telephone #: 760-755-3299
Date contacted: frJ9 ) Email: onebarrientos@hotmail.com
Mail Telephone Fax 'f'n Person
Do REMARKS: Please have the staffs show the soils stp or 1the plans. Also, please have the
designer sign each sheet of the plans and the engineerpf'iork sign & stamp the structjdral
plans.
By: Bert Domingo Enclosures:
EsGil
9/13/2018
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
V EsGil
A SAFEWIV Company
DATE: 8/29/2018
JURISDICTION: CARLSBAD
PLAN CHECK #.: CBR2018-2044
PROJECT ADDRESS: 1642 BRADY CIRCLE
SET: I
O APPLICANT
L3 JURIS.
RECE WED
SEP 12 2018
PROJECT NAME: SFD NEW UNIT ADDITION FOR GARROD aTYOF CARLSBAD
BULDNG DIVISION
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
LI The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
F-1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Es Gil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Juan Barrientos Telephone #: 760-755-3299
Date contacted: (by: ) Email: onebarrientos@hotmail.com
Mail Telephone Fax In Person
I REMARKS:
By: Bert Domingo Enclosures:
EsGil
8/20/2018
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
CARLSBAD CBR20 18-2044
8/29/2018
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK #.: CBR2018-2044 JURISDICTION: CARLSBAD
PROJECT ADDRESS: 1642 BRADY CIRCLE
FLOOR AREA: STORIES:
HEIGHT:
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 8/29/2018
FOREWORD (PLEASE READ):
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 8/20/2018
PLAN REVIEWER: Bert Domingo
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed UD the recheck process. please note on this list (or a cov) where each
correction item has been addressed. i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
CARLSBAD CBR2018-2044
8/29/2018
PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
3. Plans deviating from conventional wood frame construction shall have the
structural portions signed and sealed by the California state licensed engineer or
architect responsible for their preparation, along with structural calculations.
(California Business and Professions Code).
FIRE PROTECTION
4. Please indicate on the plans whether the existing residence has a fire sprinkler
system installed. If so, then provide a note stating that any additions/alterations
will be provided with an automatic residential fire sprinkler system. Section
R313.2. SEE NOTE ADDED TO SHEET TIOI
GENERAL RESIDENTIAL REQUIREMENTS
5. Glazing in the following locations should be shown on the plans as safety glazing
material in accordance with Section R308.4:
a) Glazing in doors.
SEE REVISED SHEET A202 FOR TEMPERED GLAZING NOTED ADDED
ROOFSIDECKSIBALCONIES
6. Note on the plans: "Attic ventilation openings shall be covered with
corrosion-resistant metal mesh with 1/16" minimum to %" maximum openings.
Section R806. I.
SEE REVISED SHEET A202 FOR NOTED ADDED
CARLSBAD CBR20 18-2044
8/29/2018
GARAGE AND CARPORTS
The garage shall be separated from the residence and its attic area by not less
than W gypsum board applied to the garage side (at walls). Garages beneath
habitable rooms shall be separated by not less than 5/8" Type X gypsum board.
Section R302.6. SEE REVISED SHEET A202 CALLOUT C2 &
A303 FOR CALLOUT F2
Show a self-closing, self-latching door, either 1-3/8" solid core or a listed 20 -
minute assembly, for openings between garage and dwelling. Section R302.5.1.
SEE REVISED SHEET A202 NOTED ADDED TO DOOR SCHEDULE
STRUCTURAL
Please show the size of the hips and valleys beams on the roof framing plan.
Please submit calculations for the same beams.
SEE REVISED STRUCTURAL SHEETS
Please show how the beams mentioned above would be supported, Please
show details. SEE REVISED STRUCTURAL SHEETS
PLUMBING
Show water heater size (1st hour rating), type, and location on plans. Note: For
both new dwellings and additions the Energy Standards (150.0(n)) requires a gas
input rating of 200,000 Btu for both tank and instantaneous gas water heaters.
(Also) Provide a gas piping design for the gas system.
SEE REVISED SHEET E102 & E102 NOTES ADDED
An instantaneous water heater is shown on the plans. Please include a gas
pipe sizing design (isometric or pipe layout) for all gas loads.
a) The gas pipe sizing for a tank type water heater shall be based upon a
minimum 199,000 Btu gas input rating. Energy Standards 150.0(n).
SEE REVISED SHEET E102 & E102 NOTES ADDED
Provide a note on the plans: The control valves in showers, tub/showers,
bathtubs, and bidets must be pressure balanced or thermostatic mixing valves.
CPC Sections 408, 409,410.
SEE REVISED SHEET E102 NOTES ADDED
Specify on the plans: Water conserving fixtures: New water closets shall use no
more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8
GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8
GPM of flow. CPC Sections 407, 408, 411, 412.
SEE REVISED SHEET E102 NOTES ADDED
CARLSBAD CBR20 18-2044
8/29/2018
Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
SEE REVISED SHEET TI 01 NOTES ADDED
RESIDENTIAL GREEN BUILDING STANDARDS
The California Building Standards Commission has adopted the Green Building
Standards Code and must be enforced by the local building official. The following
mandatory requirements for residential construction must be included on your plans.
CGC Section 101.3. The Standards apply to newly constructed residential buildings,
along with additionslalterations that increase the building's conditioned area, volume
or size. CGC Section 301.1.1. Provide a sheet on the plans labeled "Green
Building Code Requirements" and include the following notes as applicable.
Recycling. Note on the plans that a minimum of 65% of construction waste is to
be recycled. CGC Section 4.408.1. SEE REVISED SHEET T1 01 NOTES ADDED
ENERGY CONSERVATION
Include on the Title Sheet of the plans the following statement: "Compliance with
the documentation requirements of the 2016 Energy Efficiency Standards is
necessary for this project. Registered, signed, and dated copies of the
appropriate CFI R, CF2R, and CF3R forms shall be made available at necessary
intervals for Building Inspector review. Final completed forms will be available for
the building owner."
Instantaneous water heaters shall have isolation valves on both the cold and the
hot water piping leaving the water heater complete with hose bibs or other fittings
on each valve for flushing the water heater when the valves are closed. ES 110.3
All domestic hot water piping to have the following minimum insulation installed:
1,4" pipe (1/2" insulation); W pipe (1" insulation); 1" to I -W pipe (14'2"
insulation). CPC 609.11 & ES 150.00)
a) Additionally, the 1/2" hot water pipe to the kitchen sink, and the cold water
pipe within 5' of the water heater both require 1" minimum insulation. ES
150.00) SEE REVISED SHEET T1 01 NOTES ADDED
MISCELLANEOUS
Please show the recommended insulation for the walls on the sections.
SEE REVISED SHEET A303 NOTES ADDED
CARLSBAD CBR20 18-2044
8/2912018
21. May remove the CM/SD shown in the garage. May trigger noise every time you
start the engine
SEE REVISED SHEET EIOI FOR OMITTED CM/SD
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes L3 No L3
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Bert Domingo at EsGil. Thank you.
Mid-City
ARCHITECTURAL ENGINEERING INC.
RECEIVED
SEP 122018
STRUCTURAL CALCULATIONS CITY OF CARLSBA
BUILDING DVLsrON1
DATE: 7/31/18
Co1 q ( t o
PROJECT: GARROD ADDITION
1640 BRADY CIRCLE
CARLSBAD, CA 92008
DESIGNER: JUAN BARRIENTOS
(760) 755-3299
ONEBARRIENTOS@HOTMAIL.COM
JOB NO: 18-017
NOTE: THESE CALCULATIONS ARE INVALID UNLESS BEARING A WET STAMP & SIGNATURE
Digitally signed by Christopher J. Turner
CHRIS@MIDCITYENG.COM C 5Rao,8 556
Mid-City
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITYENG.COM
(619) 784-5556
J084S:
SHEET#:
CALCULATED BY:
DATE:
SCALE:
TABLE OF CONTENTS
TOPIC SHEET
.DESIGN CRITERIA
LOAD TAKE-OFF -3
VERTICAL-LOAD ANALYSIS &DESIGN 47
LATERAL- LOADANALYSIS&DESIGN
FOUNDATION AND/OR RETAINING WALL DESIGN Is
OTHER:
Mid-City
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITVENG.COM
(619) 7845556
JOB#:
SHEET#: 1.-
CALCULATED BY: -
DATE:
SCALE!
DESIGN CRITERIA
GOVERNING CODE: 2016 C.B.C. / 2015 I5.C.
SAWN LUMBER DOUGLAS FIR LARCH. ALLOWABLE STRESSES PEP, 2015 N.D.S.
I-JOISTS: BOISE-CASCADE BCI SERIES (ESR# 1336)
ENGINEERED LUMBER: BOISE-CASCADE VERSA-LAM (ESR# 1040)
GLULAMS: DOUGLAS FIR LARCH
24F-V4 FOR SIMPLE SPAN CONDITIONS
24F-V8 FOR CANTILEVER CONDITIONS
CONCRETE: ACI318-14
fc = 2500 PSI, NO SPECIAL INSPECTION REQUIRED (U.N.b.)
MASONRY: TMS4O2-13/ACI 530-13
MEDIUM WEIGHT, ASTM C90, Pm =1500 PSI
SPECIAL INSPECTION REQUIRED
MORTAR ASTM C270, fc =1800 PSI, 1'r'PE S
GROUT: ASTM C476, fc = 2000 PSI
REINFORCING STEEL: ASTM A615. Fy = 40 KSI FOR #4 AND SMALLER
ASTM A61 5, Fy = 60 K51 FOR #5 AND LARGER
STRUCTURAL STEEL: AISC 360-10
ASTM A572, Fy =501(51 (STEEL SHAPES) (U.N.0.)
ASTM ASOO, GRADE B, Fy =461(51 (STRUCTURAL TUBE)
ASTM A53, GRADES, Fy =351(91 (STRUCTURAL PIPE)
ASTM A36. Fy =361(51 (PLATES)
BOLTING: A307. SINGLE PLATE SHEAR CONNECTION
A325-N, A490-N HIGH STRENGTH, SINGLE PLATE SHEAR CONNECTION
WELDING: E70XX SERIES-TYPICAL, E90 SERIES FOR A615 GRADE 60 REBAR
SHOP WELDING TO BE DONE IN AN APPROVED FABRiCATOR'S SHOP
FIELD WELDING TO HAVE CONTINUOUS SPECIAL INSPECTION
SOIL: EXISTING NATURAL SOIL PER I.B.C. TABLE 1806.2
ALLOWABLE BEARING PRESSURE: .1.5 PSF
ACTIVE SOIL PRESSURE: PCF
ACTIVE SOIL PRESSURE (RESTRAINED): ...............PCF
PASSIVE SOIL PRESSURE: PCF
SOIL DENSITY: PCF
COEFFICIENT OF FRICTION:
SOILS REPORT BY:
PROJECT NO:
DATED:
SOIL CLASSIFICATIONS .............................................................
.0 PSF
9 2.0
3.5
2.5
2.0
.0 PSF
.O PSF
.0 PSF
.0 PSF
.0
2.0
3.5
2.5
2.0
0 PSF
.0 PSF
.0 PSF
M i d - C i t y
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITYENG.COM
(619) 784-5556
JOB$: 1-017
SHEET#: 3
CALCULATED BY:
DATE:
SCALE:
LOAD TAKE-OFF
TYPICAL ROOF LOAD OTHER ( ............ . ..... )
DEAD LOAD:
ROOFING MATERIAL (.P$C ): 10.0 PSF o PSF
SHEATHING: 1.5 .0
FRAMING: 3.5 2.0
INSULATION: 1.5 3.5
DRYWALL: 2.5 2.5
OTHER I MISC: 1.0 2.0
P LOAD..Zo....PSF ....0 PSF
LIVE LOAD (PER C.B.C. TASLE 1607.1): 1.0 .0 PSF .0 PSF
TOTAL ROOF 40.0 PSF ...0 FSF
OTHER(.................) OTHER(.................) TYPICAL FLOOR LOAD
DEAD LOAD:
FLOORING MATERIAL (...... ............ . ................... ): 4.0 PSF
LIGHTWEIGHT CONCRETE .0
SHEATHING: 2.0
FRAMING: 35
DRYWALL: 2.5
OTHER/MISC: 2.0
TOTAL DEA.P 0 .PSF
LIVE LOAD (PER C.D.C. TASLE 1607.1): 40.0 PSF
TOTAL FLOOR L, AD:.
TYPICAL EXTERIOR WALL LOAD OTHER(.................)
EXTERIOR FINISH (. ..... .''J'-............... ): 10.0 PSF .0 PSF
FRAMING: 1.0 1.0
INSULATION: 1.5 1.5
DRYWALL: 2.5 2.5
OTHER / MISC: 1.0 1.0
TOTAL OEAP LOAD..:o...PSF ...0
TYPICAL INTERIOR WALL LOAD
FRAMING: 1.0 PSF
DRYWALL: 5.0
OTHER! MISC: 1.0
TOTAL DEAD LOAD: 7.0 PSF
CALLOUT:..i,.3 ... SPAN:••4.LFT. UNIFORM LOAD ONLY? [91
wi = .............................................................. =. .... j.b PIE
W2= ..............................................................................................=......................PLF
W3 = = PLF
P1= = LOS
P2= = LOS
= LBS
RI= ' = LBS
Rr= LBS
Vmax= = LOS
Mmax == FT-LDS . .,4.5.&..
Ireq= ..................................... ............. ......=....... 5. ....... ..IN4
lK, eRr
41
OR/.= IN.
M i d - C i t y
ARCHITECTURAl. ENGINEERING INC.
CHRIS@MIDCITYENG.COM (619) 784-5556
JOB f:
SHEET#: .14.
CALCULATED BY:
DATE:
SCALE:
VERTICAL-LOAD ANALYSIS & DESIGN
LEVEL: 00
MEMBER TYPE:
CALLOUT:fl ....1 SPAN: .to FT. UNIFORM LOAD ONLY?IJ
wi = ..L )Lic....)............................................................. =....PLF
W2= ............................................................................= .................PLF I
W3=
P1= (a-z.)=......00 LBS
= PLF
V3 1
P2 = = LOS
P3= = LOS $
RI= I.8.c?.t...I.!..o................................................................=.Z2th.°....LBS
J.Z 1Z..9............................................................=3.....Rr
Ii IRr
LBS
Vmax 0 LOS
Mmax =
Ireq== INA4 ORt=IILIN.
USE: 4cVi.. -Z- OR
CALLOUT:..PP .6 ....... FT. UNIFORM LOAD ONLY?
wi= ........................................................ =...3 ..0PLF
W2= ....................................................... . ....... =...................... PLF
W3=
P1=
=
=
PLF
LOS
P2= = LOS
P3= = LOS
............................................................=..1.13 O....LBS ........
....LP ........ . ................................................ ...=...t.1,.3.P....LBS
Vmx= .LOS
Mmax = FT-LBS
Iraq= =........ . ........ IN"4
USE: 4z, OR
1I
Rh IpIr c55
ORL1=,(P't IN.
USE: 4x'4 *11 OR
M i d - C i t y
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITYENG.COM (619) 784-5556
LEVEL: 1 00 F................
MEMBERTYPE:
CALLOUT:4 ..SPAN: .5FT. UNIFORM LOAD ONLY?
wi = ..(4 ) ...)..................................................................= PLF
W2= ....................................................= ......................PLF
W3= = PLF
P1= = LBS
P2= = LOS
P3 = = LOS
RI= = LBS
Kr = = L155
Vmax= .....0 LBS
Mmax
= ....................................................................................................= . 3P.&... FT-LBS
Ireq== IN -4
USE: 4 x 4 o- Z, OR
CALLOUT: .1..LSPAN:..11.5..FT. UNIFORM LOAD ONLY2D
wi = .... )...................................................................= ....4Q.O....PLF
W2= ......................................................................................= ......................PLF
W3= = PLF
P1= = LBS
P2= = LBS
P3= = LBS qbb LOS
= •••q.i.o...................................................................=. ..... LBS
Vmax == LBS .
Mmax = ....................................................................................................= FTLBS .4.&...Q. Ireq== .....................IN '4
USE: 4x\O -.l OR
CALLOUT: .3..SPAN: FT. UNIFORM LOAD ONLY?D
wi = ...................................................................................= ......................PLF
W2= ..............................................................................................= ......................PLF
w3=
P1= ()s.7. =
= 3OO
PLF
LBS
P2= = LOS
P3 = = LOS
pi ..=
QOO
LOS
LOS
Vmax= .LBS
Mmax=
lreq= ...........= .....................IN4
USE: I t 'I 4 \J 44 't-1 OR
B.........-
SHEET#: 5
CALCULATED BY:
DATE:
SCALE:
L IRr
.4. •1
ORL,= IN.
im i IRr
.1 .1
OR = IN.
L tRr
.4.-
OR =.1_036. IN.
IN.
Mid -City
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITYENG.COM (619) 784-5556
LEVEL:
MEMBER IYPE:
CALLOUT:kSPAN: FT. UNIFORM LOAD ONLY?[]
W1= ........................= .....................PLF
W2= .. ...................... ......................PLF
W3= = PLF
P1= =OO LBS
P2= = LOS
P3= = LOS
LBS
Rr= .=..LP....LBS
Vmax= =fliOO LOS
tlmax= : =..tt...q. FT-LBS
Ireq==........-..........
IN A4
USE: 4x, 4-Z- OR
CALLOUT: SPAN: FT. UNIFORM LOAD ONLY?[--]
W1= ........................................................................=PLF
W2= ..................................................................... =......................PLF
W3= .....................................................................=PLF
P1= = L155
P2= = LOS
P3= LOS
RI= = LOS
Rr= = LOS
Vmax= = LOS
Mmax =
Ire= .IN'4
USE: OR
CALLOUT: SPAN: FT. UNIFORM LOAD ONLY2D
W1= .................................................................= ...........PLF
W2= .......................................................................................= ......................PLF
W3= .........................................................................=PLF
P1= = LBS
P2= = LOS
P3= = LOS
RI = . . = LBS
Rr= = LOS
Vmax= = LOS
Mmax =
Ireq=INA4
JO8#: (-0(7
SHEET #:
CALCULATED BY:
DATE:
SCALE:
I
L IRr
IStS
IN.
L IpIr
IN.
USE: OR
M i d C i t y
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCIIVENG.COM
(619) 784-5556
JOB #: lj-o11
SHEET...
CALOJIATEDRY:
DATE:
SCALE:
SEISMIC DIAPHRAGM DEAD LOADS
ROOF DIAPHRAGM:
ROOF (SLOPED):
ROOF (FLAT):
ROOF (PECK):
EXTERIOR WALLS:
INTERIOR WALLS:
DEAD LOAD (PSF) I AREA (50. FT.) LENGTH (FT.) I PLATE HI. (FT.) WEIGHT (05.)
20 3,&97 - - 77.940
0 0 - - 0
O 0 - -, 0
16 - 325 10 26.240
7 - 200 10 7.000
TOTAL ROOF DIAPHRAGM AREA = M97 SQ, FT.
TOTAL ROOF DIAPHRAGM WEIGHT = 1111W
EQUIVALENT LATERAL FORCE PROCEDURE
INPUT DATA:
ZIP COPE = 92008
IMPORTANCE FACTOR = 1.0
SITE CLASS = P
Ct= 0.02
65
(OR LATITUDE & LONGITUDE FOR ACCURACY)
SEISMIC DESIGN CRITERIA: (FROM 5EIMICFAcTOR.COM)
= 1125 Sms = 0.01
5; = 0.433 5, = 0.007
Fa = 1.049 Sfro = 0.789
= 1567 = 0.42
VERTICAL OIS1RIUTiON OF FORCES:
MSE SHEAR, V = 0.121 W (LRFD
= 13.49 KIPS (LRFP)
SEISMIC DIAPHRAGM LOAD
ROOF DIAPHRAGM:
STORY LOAD (LRFD) = 135 KIPS
STORY LOAD (ASP) = 9.4 KIPS
ROOF DIAPHRAGM SHEAR LOAD = 2 fE
M i d C y
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITYENG.COM
(619) 784-5556
JOB #: I ,-o7
SHEET 0:
CALCULATED BY:
DATE:
SCALE:
WIND ANALYSIS (ASCE 7-10)
INPUT DATA:
EXPOSURE CATEGORY =13
IMPORTANCE FACTOR, I = 1.00
BASIC WINE) SPEED, V = 110 MPH
TOPOGRAPHIC FACTOR. = 1.00
BUILDING HEIGHT TO EAVE. hG = 10 FT.
BUILDING HEIGHT 10 RIDGE, h. = 20 FT.
BUILDING LENGTH, I = 103 FT.
BUILDING WIDTH. W = 56 Fl.
EFFECTIVE AREA OF COMPONENTS. A 0 SOFT.
ANALYSIS:
VELOCITY PRESSURE, = 0.00256 KhK,rKoV9 1& f.E
WHERE: cj = VELOCITY PRESSURE, ,. AT MEAN ROOF HEIGHT, Ii
VELOCITY PRESSURE EXPOSURE COEFFICIENT EVALUATED AT HEIGHT. h = 0.70
r WIND DIRECTIONALITY FACTOR =0.85
= MEAN ROOF HEIGHT = 15 FT.
QEIGN PRESSURES FOR MAIN WIND-FORCE RESISTING SYSTEM:
PRESSURE (IN APPROPRIATE ZONE), p = (GCXGc))
WHERE: G'C 1 = PRODUCT OF GUST EFFECT FACTOR AND EXTERNAL PRESSURE COEFFICIENT =0.113
PRODUCT OF GUST EFFECT FACTOR AND INTERNAL PRESSURE COEFFICIENT = -0.18
a = WIDTH OF EDGE STRIPS = 5.60 FT.
NET PRESSURES. BASIC LOAD CASES, (PSF)
ROOF ANGLE = I 19.65 ROOF ANGLE = I 0.00
SURFACE NET PRESSURE W/ NET PRESSURE WI G cf *GC G
1 0.52 629 1 12.93 1 -0.45 : -11.61 -495
2 1 -0.69 -15.03 s. -9.40 -0.69 -16.03. -9.40
5 -0.47 -12.03 -5.39 -0.37 -10.14 -3.50
4 -0.42 -11.07 -4.44 -11.61 -4.98.
5 0.40 4.05 10.69
-------- - ---- 1E ' 0.79 11.19 .]7.3 -0.48 -12.16 -5.53 1 2E -1.07 1, -23.04 1 -16.40 -1.070 23.04 -16.40
SE -0.68 -15.84 -9.20 -05.3 -13.09 -6.45
4E -0.63 -14.86 -8.22 1 -0.48 -12.16 -5.53
SE 1 0.610 ' 795 1 1456
-0.430 1 -1124 • -4.61
Transverse Direction
mid -citg
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITVENG.COM
(619) 784-5556
JOB #: l%- otl
SHEET#:
CALCULATED BY:
DATE:
SCALE:
WIND ANALYSIS (CONTINUED)
BASIC LOADCASES IN TRANS. DIRECTION
SURFACE AREA
(SOFT.)
PRESSURE (k) WITH
sG -Gc
1
2
3
4
1E
2E
SE
4E
915 5.78 11.87
2729 -43.77 -25.66
2729 -32.83 -14.72
91S -1016 -4.07
112 1.25 2.00
333 -767 -5.46
335 -5.27 -3.06
112 466 -0.92
SUM HORIi 14.37 14.37
VERI. -&4.33 -46.06
ASCE
MIN.
I-IORIZ. 32.96 32.96
VERT. -9229 -92.29
A5IC LOAD CASES IN LONG. DIRECTION
SURFACE AREA PRESSURE () WITH
(SOFT.) +GC -GC,
2 2729 -43.77 -25.66
3 2729 -27.67 -956
5 77,5 3.16 &32
6 776 -6.74 -1.5
2E 335 -7.67 -5.4
3E 335 -4.36 215
SE 62 0.49 0.90
6E
SUM HORIL 11.0& 11.08
VER1. -7b.60 -40.33
ASCE J-IORii 13.44 13.44
MIN. VERI. 1 -9229 1 -9229
Longitudinal Direction
Basic Load Cases
DESIGN SUMMARY:
MAX HORIZONTAL FORCE NORMAL TO 6UILPING FACE ALONG LENGTH (SD). I = 32.96 II
MAX HORIZONTAL FORCE NORMAL TO 5UILDING FACE ALONG WIDTH (SO). W = j KIM
MAX TOTAL UPWARD FORCE = 92.29 iie
Mid-Ci t g
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCI1YENG.COM
(619) 784-5556
109 #: OI.7
SHEET#: 9
CALCIJLATIDBY:
DATE:
SCALE:
WIND LOAD DISTRIBUTION
DIAPHRAGM 0I5TRIUTI0N:
N-S WINO VALUES (PROJECTION 11): E-W WINO VALUES (PROJEcTION #1):
GRIOUNES: X - X
TOTAL WINO LOAD = 13.44 KIPS
ROOF HEIGHT = 10.0 FT.
PLATE HEIGHT = 10.0 FT.
TRIU1ARY WIDTH = 56.0 Fl.
APJ. WINO LOAD (ASP) = 605 KIPS
UNIFORM WINO LOAD Al ROOF PLATE = 10 ELE
GRIPLINES: X - X
TOTAL WINO LOAD 52.96 KIPS
ROOF HEIGHT = 10.0 FT.
PLATE HEIGHT = 10.0 FT.
TRI6UTARY WIDTH = 103.0 Fl.
ADJ. WIND LOAD (ASP) = 14.& KIPS
UNIFORM WINO LOAD AT ROOF PLATE = 14A fLE
N-S WINO VALUES (PROJECTION #2):
GRIDLINES: - GRIPLINES:
TOTAL WINO LOAD = KIPS TOTAL WIND LOAD = KIPS
ROOF HEIGHT = FT. ROOF HEIGHT = FT.
PLATE HEIGHT FT. PLATE HEIGHT = FT.
TRIBUTARY WIDTH = FT. lRIUTARY WIDTH = FT.
ADJ. WINO LOAD (ASP) = KIPS ADJ. WINO LOAD (ASP) = KIPS
UNIFORM WIND LOAD AT ROOF PLATE = fLE UNIFORM WIND LOAD AT ROOF PLATE =
N-S WIND VALUES (PROJECTION #3): E-W WINE) VALUES (PROJECTION #3):
GRIOLINES: - GRIDLINES: -
TOTAL WINO LOAD = KIPS TOTAL WINO LOAD KIPS
ROOF HEIGHT = FT. ROOF HEIGHT = Fr.
PLATE HEIGHT = FT. PLATE HEIGHT = FT.
TRIUTARY WIDTH =. FT. TRIUTARYWIPTH = FT.
ADJ. WIND LOAD (ASP) = KIPS ADJ. WINO LOAD (ASP) KIPS
UNIFORM WIND LOAD AT ROOF PLATE = ftE UNIFORM WIND LOAD AT ROOF PLATE =
"ADJUSTED WIND LOAD" IS THE RATIO OF THE "TOTAL WINO LOAD" MULTIPLIED Dy
THE 'TOTAL HEIGHT OF THE STRUCTURE' DIVIDED DY
THE 'TOTAL HEIGHT OF THE STRUCTURE LESS HALF THE HEIGHT OF THE 151 FLOOR"
LE
fLE
M id -C i ty
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCI1YENG.COM
(619) 784-5556
CALCUlATDBY:
SCAII:
DATE:..........................................................
SHEARWALL DESIGN
ROOF N-5:
Gg[PUNE. LI (E1SM1C) RHO = 1.0 Vc= Zf
TRIBUTARY AREA 1 = 639 SOFT.
TRIBUTARY AREA 2= SOFT. ION) = (v)(r.A. /2) = ZM L13-5
ADDITIONAL LOAD 1 = LBS x 0 LS
ADDITIONAL LOAD 2= LBSx 0 LBS (RHO)(SUM LOADS) = 2Z k
S.W. LENGTHS (FT.) = 8.00 S.W. SUM = k= EL
INCREASE LOAD FOR WALL > 2:1 RATIO? NO (TOTAL. LOAP)/ (S.W. SUM) = 91fE
STRONG WAIL I HARPYFRAME? NO
I
0EKtQI
WALL LENGTH (FT.) 8.00
hEA WAL) (L) = 714
PLATE HEIGHT (FT.) = 10.0
TRIBUTARY DL (PLF) = 160
POINT DEAD LOAD (LOS) =
POINT DL ARM (FT.)
01' MOMENT (FT-LBS) = 7.744
RESIS1'G MOMENT (FT-LBS) 2.507
UPLIFT (LOS) 655
UPLIFT FROM ABV (LOS)
TOTAL UUFT (11*) = N/A
GgKaLINE; Ii MINI?)
WINO PROJECTION /: 1
TRIBUTARY LENGTH: .33 FT.
ADDITIONAL LOAD 1= LBS x
ADDITIONAL LOAD 2= LBS
S.W. LENGTHS (FT.) = 6.00
V= JQLE
LOAD = (Vx)(TA / 2) = 1.72 k
= OLBS
= 0 LOS TOTAL LOAD = 122 L
REDUCED LOAD (SEC. 2306.3) = 127J LB
I I S.W. SLIM = .QQ EL
(TOTAL LOAD)! (SW. SUM) = 3.59 ELE
STRONG V/ALL / HAROYFgAME? NO
UUY.E 1 StW_PER.5KE&RWALL_5 MUM
OV ER tIJK
WALL LENGTH (FT.) 8.00
5L1EAK LUAU (Lbs) =1270
PLATE HEIGHT (FT.) = 10
TRIBUTARY DL (PLF) = 160
POINT PEAL) LOAD (LOS) = 0
POINT Pt. ARM (FT.) = 0.00
01 MOMENT (FT-LOS) = 12.729
RESISIG MOMENT (r1'-LDS) = 3,072
UPLIFT (155) = 1,207
UPLIFT FROM A5V (155) =
I
______ ______
TOJ AL uruti (Lbs) = 1.207
HOQWNXPSEP
M i - :iii i ~g ci SHE a 0
ARCHITECTURAL ENGINEERING INC. CALCULATED BY:
CHRIS@MIDCIlYENG.COM
(619) 784-5556 SCALE:
SHEARWALL DESIGN
ROOF N-5:
IPijN; LA LiMtc) RHO= 1.0 Vx = 2.2
TRIBUTARY AREA 1= 639 .SQFT.
TRIBUTARY AREA 2= SQFT LOAD = (yx)(T.A. /2) = ZZ. t.
Aprriot LOAD I = LDS x 0 LBS
ADDITIONAL LOAD 2 lBS x = 0 LBS (RHO)(5UM LOADS) = WI k
5.W. LENGTHS (FT.= .6.92 6.92 S.W.SUM= I3. Et
INCREASE LOAD FOR WALL > 2:1 RATIO NO (TOTAL LOAD) / (5.W. SUM) = 5
STRONG WALL / HARPYFRAME? NO
iLTX1E I £WHgwALLUIE4Mi!!t4VM)
WALL LENGTH (FT.) = 6.92 6.92
5I-AK WA') (WS) i b7
PLATE HEIGHT (FT.) = lO/L) 10.0
TRIBUTARY DL (PIF) = 160 160
POINT DEAD LOAD (LBS) =
POINT Pt. ARM (FT.) =
Or MOMEI (FT-135) = 3,872 3,872
RESIST'G MOMENT (FT-05) = 1.875 1,875
UPLIFT (LBS) = 288 208
UPLIFT FROM ASV (165) = I _____ 101 AL UrLIFT (Lb5) = NIA I NIA
&Il.INg: L (WIND) = 10 LE
WIND PROJECTION #: 1
TRIBUTARY LENGTH: 35 FT. LOAD = (V))(T.A. /2) = 12.82 L
ADDITIONAl. LOAD 1= 1139 c = 0 LDS,
ADDITIONAL LOAD 2= 169 ,c = 0 1135 TOTAL LOAD = .12.82 L
REDUCED LOAD (SEC. 2306.3) = L21 L5
5.W. LENGTHS (FT.)= 6.92 6.92 5.W. SUM = 18.4E.L
(TOTAL LOAD) / (5.W. SUM) = 2 fLE
STRONG WALL I HARDY FRAME? NO
USE iYfE 1 SA.F-EjZ5HE69Wft
7.VEIT.Uit,1IL;
WALL LENGTH (FT.) = 6.92 6.92
)*.AR LOAf) 4L05) = 6i6
PLATE HEIGHT (FE)= 10 10
TRIBUTARY DL (PLF) = 160 160
POINT DEAD LOAD (165) = 0 0
POINT DL ARM (FT.) = 0.00 0.00
01 MOMENT (FT-LDS) = 6.364 6.364
RE5I5T MOMENT (FT-165) = 2,299 2,299
UPLIFI (1135) = 508 588
UPLIFT FROM ABV (LBS) = 1 1
101AL WLIEI (LS) = U/A N/A
M id -C i ty
ARCHITECTURAL ENGINEERING INC. CALCULATED BY:
CHRIS@MIDCITYENG.COM
(619) 784-5556 SCALE:
SHEARWALL DESIGN
ROOF E-W:
JiUN 13. (05i1C) RHO = 1.0
TRIBUTARY AREA 1= 1,50 SQFT.
TRIBUTARY AREA 2 = SOFT.
ADDITIONAL LOAD 1 LBS x = 0 LOS
ADDITIONAL LOAD 2= LOS ' = 0 LS
S.W. LENGTHS (FT.) = 1150 1
.
1750
INCREASE LOAD FOR WALL> 2:1 RATIO? NO
STRONG WALL / HARPYFRAME? NO
.1tSEJXEE I ARWAkLPULL(MINiMUJ1)
E&TiJiIL
Vx= 2.42HESf
LOAD = (Vx)(LA. F 2) = :I.6. L
(RHO)(SUM LOADS) IQ6 I.
S.W. SUM = 29QQ EL
(TOTAL LOAD) I (S.W. SUM) = 5. .ELL
WALL LENGTh (FT.) = 1150 1750
5M.A LOAD L) = t49 9b•/
PLATE HEIGHT (FT.)= 10.0 10.0
TRIBUTARY DL (PLF) = 70 10
POINT DEAD LOAD (LOS) =
POINT DL ARM (FT.) =
01 MOMENT (FT-1.55) = 6,488 9,872
RESISVG MOMENT (FT-LBS) = 2,266 5.247
UPLIFT(LOS) = 361 264
UPLIFT FROM AN (155) =
TOTAL urui (L)= N/A N/A
1QLINE: T6 M-100 V= 14fLE
WIND PROJECTION
TRIBUTARY LENGTH: 53 FT. LOAD = V,c)(T.A. /2) = 316 LS
ADDITIONAL LOAD 1 = 155 x = 0 135
ADDITIONAL LOAD 2= LOS x = 0 LBS TOTAL LOAD = 3.01ro 1.55
REDUCED LOAD (SEC. 2306.3) = 2.726 155
5.W. LENGTHS (FT.) 11.50 17.50 S.W. SUM = 29.QQ El.
(TOTAL LOAD) / (5.W. SUM) = 94 ELE
STgOUGWALL I HARDYFRAIYIE? NO
USE 3Y1 1 HEAWLLPUkMINiMUM)
QTA)iN
WALL LENGTH (FT.) = 11.50 17.50
,bHtAK WALl (LI*) = Wi lro4to
PLATE HEIGHT (FT.) = 10 10
TRIBUTARY DL (PLF) = 70 70
POINT DEAD LOAD (155) 0 0
POINT DL ARM (FT.) = 0.00 0.00
Or MOMENT (FT-1.55) = 10,809 16.448
re5l5rG MOMENT (FT-05) = 2.777 6.431
UPLIFT (LBS)= 698 512
UPLIFT FROM ABY (LOS) =
101 AL U11111 (Lbs) = N/A N/A
HOLPOWN.TE.EL5CHEP,
Mdi - Cttg
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITYENG.COM
(619) 784-5556
SHEET: (3
CALCULATED BY:
DATE:
SCALE:
SHEARWALL DESIGN
ROOF E-W:
G8IPIJNE 1:2 (5EiMtC) RHO = 1.0
TRIBUTARY AREA 1 = 22 SOFT.
TRIBUTARY AREA 2 = SOFT
ADDITIONAL LOAD 1= 165 x
ADDITIONAL LOAD 2= 165 x =
S.W. LENGTHS (FT.) = 3.42 1 .3.42
INCREASE LOAD FOR WALL > 2:1 RATIO? YES
STRONGWALL I HARPYFRAME? NO
UsEIriE I
Yx = 242 fE
LOAD = Vx)(T.A I 2) = 2.J !
0185
0 185 (IZHO)(SUM LOADS) = z8j L-0-5
I S.W. SUM = 6,i EL
(LOAD)(H/21)l (S.W. SUM) = Q f3f
WALL LENGTH(FT.).= 342 I 3.42
MAK WAI) (W5) 20b 20
PLATE HEIGHT (FT.) = 10.0 10.0
TRIBUTARY DL (PLF) = 160 160
POINT DEAD LOAD (165) =
POINT 01. ARM (FT.)
OT MOMENT (FI-IBS) =. 2.055 2.055
RESIST'G MOMENT (FT-LBS) = 458 458
UPLIFT (165) = 467 47
UPLIFT FROM ABV (165) =
TOTAL UPLIFT L55) = N/A I N/A
J1PUNE: 1:2 .(WJNP)
WIND PROjECTION ii:. 1
TRIBUTARY LENGTH 20 FT.
ADDITIONAL LOAD 1= LS x
ADDITIONAL LOAD 2 = LBS x
S.W. LENGTHS (FT.) = 3.42
Vx = U-4 fLf
LOAD =(Vz)(T.A./2)= 3,400.
= OLBS
= 0 LBS TOTAL LOAD = L410 L
REDUCED LOAD (SEC. 2306.3) = 10-2 L8
3.42 I I 1 1 S.W. SUM = 6. EL
(TOTAL LOAD)! (S.W. SUM) = ISQ ELE
STRONGWALL / HARDYFRAME? NO
U1Y.EE 1 5RWAkL$.Ct.ULE(MJMMUM)
WALL LENGTH (FT.) = 342 1 3.42
5HtAK LOA L) (LbS) = 14 514
PLATE HEIGHT (El) = 10 10
TRIBUTARY DL (PLF) 360 160
P01141 DEAD LOAD (1.65) = 0 0
P0114101. ARM (FT.) = 0.00 0.00
Or MOMENT (FT-155) = 5.143 5.143
RE5I5T MOMENT (P1-165) = 563 561
UPLIFT (135) = 1.340 1.4O
UPLIFT FROM ABY (135)
TO( dL UPLIrT (05) = I,4Q 1.4Q
NOLQWN.TPE.SQtEP.
i - (:1111; i ty: .... .. SNE.U.#.:
ARCHITECTURAL ENGINEERING INC. CALCULATED BY:
CHRIS@MIDCITYENG.COM DATE.
(619) 784-5556 SCALE:
SHEARWALL DESIGN
ROOF E-W:
(I1241NE: I] (E[SMC) RHO = 10 = 2.2 f.E
TRIBUTARY AREA 1 = 407 SOFT.
TRIBUTARY AREA 2= SOFT. LOAD = / 2) = 193 L
ADDITIONAl. LOAD 1= LBS h 0 LOS
ADDITIONAL LOAD 2= LBS x 0 LBS (RHO)(SUM LOADS) = Am W-5
S.W. LENGTHS (FT.) = 4.00 S.W. SUM = AW El.
INCREASE LOAD FOR WAIL >2:1 RATIO? YES (LOA6)(H/2t) / (5.W. SUM) = 175 LE
STROIG WAIL I HARP?FIZAME? NO
U5UT1 1
WALL LENGTH (FT.) = 4.00
SNEAK LOAD (LBS) =617
PLATE HEIGHT (FT.) 10.0
TRIBUTARY DL (PIF) = 160
POINT DEAD LOAD (IBS) =
POINT Dl. ARM (FT.) =
01 MOMENT (FT-LBS) = 6.165
RESISDG MOMENT (FT-LBS) = 627
UPLIFT (LBS) = 1,385
UPUFI FROM ABV (LOS) = I
TOTAL UPLU9 (LbS) =
RJUi Ti (W1itP) YX = 1It fLE
WIND PROJECTION ii: 1
TRIBUTARY LENGTH: 20 FT. LOAD = (V)(T.A. I 2) 141Q
ADDITIONAL LOAD 1 = L65 x = 0 LBS
ADDITIONAL LOAD 2 LOS x = 0 LBS TOTAL LOAD = J.41Q LB
REDUCED LOAD (SEC. 206.) = i.Q29 LB
S.W. LENGTHS (FT.) = 4.00 S.W. SUM = O EL
(TOTAL LOAD) I (5.W. SUM) = 29 ELE
STRONG WAIL / HARDYFRAME? NO
USLT.YE 1 W.ElEARWALL2UL(MINIMUM)
IULLK
WALL LENGTH (FT.) = 4.00
hEM LO/W (Lbb) =
PLATE HEIGHT (FT.) = 10
TRIBUTARY DL (PLF) = 160
POINT DEAD LOAD (IBS) = 0
POINT DI. ARM (FL) = 0.00
01 MOMENT (FT-LBS) = 10,286
RE5I5T5 MOMENT (FT-LBS) lee)
UPLIFT (IBS) = 2.379
UPLIFT FROM ABV (15$) =
TOTAL WLUI (Lbs) =
HQLOWN.PE1P.
Mid-Ci t y
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITYENG.COM
(619) 784-5556
JOB...
SHEET#: 15
CALCULATED BY:
DATE:
SCALE:
FOUNDATION DESIGN
ALLOWA6LE BEARING PRESSURE, q =. (.5P.Q ... PSF (PER DESIGN CRITERIA)
CONTINUOUS PERIMETER / INTERIOR SEARING WALL FOOTINGS
LOCATION:........ Li.-..............
=....(.4 C.J. .)Ci.o.............................................................= ..5..0 PLF
WIDTH REQUIRED = (Wi / ci) x 12=.................................................................................................. INCHES
USE: USE:..j.t....WIDEx ....LZ-..DEEP WITH..TZ....#4 TOP &6O1TOM
LOCATION: ...................................................................................................
W2= .................................................................................................................................................... = . ............... . PLF
WIDTH REQUIRED =(W2/cØx12=. ....................... ........................... . ................. . ....................... .. = ..........INCHES
USE: WIDE x DEEP WITH # TOP & E30TTOM
LOCA11ON: ......................
W3=.........................................................................................
......
.......... .....
....... ...
............................=PLF
WIDTH REQUIRED =(W3/q) xl 2 =...............................................................................................= ..........INCHES
USE: WIDE x DEEP WITH # TOP & BOTTOM
ISOLATED SPREAD / PAD FOOTINGS:
CALLOUT: (F-1)
P1= = LS
Areqd=(P1/qx144)= ...............................................................................................................= .............SQ.IN.
USE: D PER PAD FOOTING SCHEDULE
CALLOUT: (F-2)
P2= LDS
Areqd=(P2/qx144)=. .......... ........... ........................................................................................ ...............SQ.IN.
USE: n PER PAD FOOTING SCHEDULE
CALLOUT: (F-3)
P3=... ................................................. ............. . ................................................................................. .=LS
Areqd =(P3/qx144)=. ............................................................................................................. .. ............. SQ. IN.
USE: n PER PAD FOOTING SCHEDULE
CALLOUT: (F-4)
P4=
Ark~. =(P4/qx144)=. ........... . ........ ......................................................................................... .. ............. SQ.IN.
USE: U PER PAD FOOTING SCHEDULE
Mid -CiL y
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITVENG.COM
(619) 784-5556
JOB #: 18-017-GARROD
SHEET#: 1
CALCULATED BY: C.T.
DATE: 1/2/19
SCALE:
C75761
EXP 6/3OIW H
* ó7v*1
Civi
RECEIVED
JAN 102019
CITY OF CARLSBAD
BUILDING DiVISION
VAI
FOUNDATION PLAN
M - - .
JOB A: 18-017 - GARROD
SHEETA 2
ARCHITECTURAL ENGINEERING INC. CALCULATED BY: .C.1.
CHRIS@MIDCITVENG.COM DATE: 1./2/1.
(619) 784-5556 . SCALE:
FES
C 7576:1
2xSTU()S PEP, PLAN -
(FRAME FOR ELEC., GAS
PANEL 1ST POUR) 12" LONG #4 DOWELS
/ gi12O.C.
.. sz,~-.
/ 5LA PER PLAN
I. I
van
MIN.
1ST POUR CONT. • •
FOOTING PER
9 PLAN
OZ U > n_ -
_ARS(TOP&TM.)
12 LONG #4 OOWELS 1-2N1' POUR TIE-IN FIG.
@ 12 O.C. TOP & TM. 1-0 MIN. 6" MIN. & SLAB
CONT. FIG. DETAIL
N FDN SL 1ST CONT EXT 1
Mid -Ci t y
ARCHITECTURAL ENGINEERING INC.
CHRIS@MIDCITYENG.COM
(619) 784-5556
JOB #: 18-017 - GARROD
SHEET#: 1
CALCULATED BY: C.T.
9/10/18
SCALE:
CORRECTION RESPONSES
CORRECTION #9
HIP & VALLEY CALLOUTS ADDED, CALC PAGES 5-5a REVISED/ADDED.
CORRECTION #10
KICKERS AND CEILING SEAMS ADDED, I2ETAIL5 10 & 11/52.0 ADDED. ALSO SEE FRAMING NOTES #10-12
FOR TYPICAL SEAM SUPPORT.
SEP 122018
CITY OF CARLSBAD
BUILDING DIVISION
(bty of
Carlsbad
This form must be completed by the City, the applicant, and the appropriate school districts and returnd to the City prior
to issuing a building permit. The City will not issue any building permit without a completed school fee rorm.
Project No. & Name:
Plan Check No.: CBR2018-2044
Project Address: 1642 BRADY CIR
Assessor's Parcel No.: 2054401900 -
Project Applicant: COOWNER GARROD PAUL T AND LAURA M
(Owner Name)
Residential Square Feet:
New/Additions:
Second Dwelling Unit: 640
Commercial Square Feet:
New/Additions:
City Certification: City of Carlsbad Building Division Date: 08/29/2018
Certification of Applicant/Owners. The person executing this declaration (Owner') certifies
under penalty of perjury that (1) the information provided above is correct and true to the
best of the Owner's knowledge, and that the Owner will file an amended certification of
payment and pay the additional fee if Owner requests an increase in the number of
dwelling units or square footage after the building permit is issued or if the initial
determination of units or square footage is found to be incorrect, and that (2) the Owner is
the owner/developer of the above described project(s), or that the person executing this
declaration is authorized to sign on behalf of the Owner.
Carlsbad Unified School District
6225 El Camino Real
Carlsbad CA 92009
Phone: (760) 331-5000
Encinitas Union School District
101 South Rancho Santa Fe Rd
Encinitas, CA 92024
Phone: (760) 944-4300 x1166
IJLJ San Dieguito Union H.S. District
684 Requeza Dr.
Encinitas, CA 92024
Phone: (760) 753-6491 Ext 5514
(By Appt. Only)
177-7-1 San Marcos Unified Sch. District
255 Pico Ave Ste. 100
San Marcos, CA 92069
Phone: (760) 290-2649
Contact: Katherine Marcelja
(By Appt.only)
Vista Unified School District
1234 Arcadia Drive
Vista CA 92083
Phone: (760) 726-2170 x2222
U
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(s)
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQtJIREMENTS
FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED.
The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder,
or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1
has paid all amounts or completed other applicable school mitigation detertiined by the School District. The
City may issue building permits for this project.
Signature of Authorized School District Official:
Title
CARLSBAD UNIFIED SCHOOL DISTRICT Name of School District: _ =a •••••
CARLSBAD, CA 92009
Building Division
Date:
Phone: i(ôO 33 1-ôôô
1635 Faraday Avenue I Carlsbad, CA 92008 1 760-602-2719 1 760-602-8558 fax I btjilding@carlsbadca.gov
STORM WATER COMPLIANCE FORM
TIER I CONSTRUCTION SWPPP L1t RIMMIIIIIIIIIIIII
BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE
Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs
E :3 0. . .' a,
Best Management Practice* 0 - - a, - -
(BMP)Description —) co - !
toE
o 0 .,. -o w c. c 00 0L -o 0 . >Q). -gE zO o -- 0 .,. =c C NC CC
a, 0 0 '- W .2 U) U) 0) Cfl .0 (.) 2 LA_n> i.. .... 0 0 cn i... in Q ..-. 01 cn £ ..-. 0 U) u 0 0 0 0 o a, > c.
0 ...
U,
0 M cn 0 cn 0 00 n M 0 0 = M 0 0 0 M.
CASQA Designation — N. 00 o N) IC) CO N CD V4 F7 rj. Go T 04.
? 1- to ? T
Construction Activity W W W W U) Cfl (flY U)
Grading/Soil Disturbance — — -- — — — — — —
)c Trenching/Excavation
- Stockpiling
— Drilling/Boring — — — — — — — — Concrete/Asphalt Sawcutting — — — — — — — — — — Concrete Flatwork
--
Paving
--
— — — — — — Conduit/Pipe Installation — — — — — — Stucco/Mortar Work
—
-- -- — — — — —
— Waste Disposal ,- -- — — — — — — Staging/Lay Down Area — — — — — — — — — — — — L — .L.... ..L..
— Equipment Maintenance and Fueling
-- --
--
—
--
--
— — — — — — — — — Hazardous Substance Use/Storage
— Dewatering
--
Site Access Across Dirt
—
- Other (list): — — — -- — — — — — — Instructions:
Check the box to the left of all applicable* construction activity (first column) expected to occur during construction.
Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the •box where the chosen activity row intersects with the BMP column.
Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project.
STORM WATER POLLUTION PREVENTION NOTES
ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE
AVAILABLE ON SITE TO FACILITATE RAPID INSTALLA11ON
OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN
IS EMINENT.
THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION
CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION
OF THE CITY INSPECTOR AFTER EACH RUN—OFF PRODUCING
RAINFALL.
THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION
CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY
INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE.
ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE
AT THE END OF EACH WORKING DAY WHEN THE FIVE (5)
DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT
(407.). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER
EACH RAINFALL.
ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM
AGGREGATE.
ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER
PROTEC11ON BEST MANAGEMENT PRACTICE MEASURES MUST
BE INSTALLED AND MAINTAINED.
THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER
THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED
TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY
REGULATIONS.
OWNER'S CERTIFICATE:
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT
BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION
ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID
THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO
AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION
RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES,
COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED
BY THE CITY OF CARLSBAD.
E-29
IbI is( I
DATE
PROJECT INFORMATION
Site Address: 1 I 4 - 1315P17'( (t-(—
Assessor's Parcel Number: _-LjC4'rj — iq 00
Emergency C,ct:
Name: _U(..AI 0 1
24 Hour Phone:____________________
Construction Threat to Storm Water Quality
(Check Box)
0 MEDIUM 0 LOW
Page 1 of 1 REV11/17