HomeMy WebLinkAbout1657 AMANTE CT; ; CBR2016-0459; PermitPrint Date: 01/10/2017 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 1657 Amante a BLDG-Residential 2159006000 $0.00 City of Car.lsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit www .carlsbadca.gov Work Class: lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: P/M/E Description: MALGET: INSTALL2 NEW AC UNITS PLUMBING, ELECTRICAL, AND MECHANICAL PERMIT Total Fees: $166.00 Owner: JIMMY MALGET 1657 Amante Ct CARLSBAD, CA 92011 Total Payments To Date: $166.00 Status: Applied: Issued: Finaled: Inspector: Contractor: GUTHRIE AND SONS INC 3914 Hicock St San Diego, CA 92110-4316 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBR2016-0459 Closed -Finaled 12/27/2016 12/27/2016 $0.00 $166.00 ·' , THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING .0 ENGINEERING 0BUILDING OFIRE 0HEALTH 0HAZMATIAPCD Catyof Carlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov PlanCheckNo.~Q..~\Co-0~~9 Est. Value EXISTING USE APPUCANT NAME Primary Contact ADDRESS CITY PHONE EMAIL DESIGN PROFESSIONA ADDRESS CITY PHONE EMAIL PROPOSED USE STATE FAX STATE FAX #BEDROOMS GARAGE (SF) ZIP ZIP STATE LIC. # SUITEI/SPACEf/UNITf #BATHROOMS SWPPP CllY BUS. LIC.# OCC.GROUP FIRE SPRINKLERS YESONoO (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish orr pair an~ structure, prior to Its issuance, also requires the applicant for such permit to file a sil1)led statement that he is licensed pursuant to the provisions ofthe Contractor's License Law !Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exemP.t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than fiVe hundred dollars {$500}). WORI<ERS' COMPENSATION Worilers' Compensation Declarstion: I hereby affirm under penalty of Pfll1ury one of the following declllf!ltions: 0 I have and will maintain a certificate of consent to self·lnsure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, ::~er:n 3700 of the Labor Code, for the perform~ of the work for which this permit is issued. My workers' compensjliO~Ij!Q<iU.canier and policy number are: Insurance Co~ MA~ Policy No. -r:Z..(J-J eL-t:@..<?fMZ, Expiration Date _UI=,JJ--'--l-\-c-'1~ "r ___ _ J!!§,section need not be completed if the permit is for one hundred dollars ($1 00) or less. U Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars {&100,000), In addition to the Section Interest and attorney's fees. I hereby affirm that I am exempt from Contractor's License Law for the following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's Ucense Law does not apply to an owner of property who builds or improves thereon, and who does such work himseH or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's Ucense Law). I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Ov es 0No 2. I (have I have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supeiVise and provide the major work (include name I address I phone I contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work): 1$ PROPERTY OWNER SIGNATURE 0AGENT DATE .\ COMPLETE THIS SECTION FOfl NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration rorm or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Acrl []Yes []No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management districrl []Yes [] No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? []Yes [] No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have mad the application and slatB that the abolie lnfonnallon Is mnectand that the lnfonnation on the plans Is IIOCUill1e.l agree Ill mmplywlth all Cfl¥onlnances and S1a1e laiNs relating Ill building mnstruction. I hereby authorize represenlalive of the City of Carlsbad to enter upon the above mentioned property tJr inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All UABILITIJ:P, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: kl OSHA perm I is requied tJr excavations over SO' deep and demolition or construction of slruclures over 3 skllies i1 height. EXPIRATION: Every perm I issued · · and bemme nuU and void ff the buikling or 'Mllk authori2ed t7f such permit is not rommenred v.ithin 180days from the dale of such at anytime aflerthemrk is rommenred bra period of180days (SecOOn 100.4.4 Uniform Building Code). A$ APPUCANT'S SIGNIATilNi..-lf_:~~'C.,./ STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email buildinq@carlsbadca.gov or Mail the completed fonn to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. DB.NERY OPnONS [] PICK UP: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. i) [] MAIL TO: o ·CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. i) []MAIL/ FAX TO OTHER:---------------- A$ APPUCANT'S SIGNATURE (Office Use Only) CA o ASSOCIATEDCB#----------- o NO CHANGE IN USE/ NO CONSTRUCTION o CHANGE OF USE/ NO CONSTRUCTION DATE PERMIT INSPECTION HISTORY REPORT (CBR2016-0459) Permit Type: BLDG-Residential Application Date: 12/27/2016 Owner: JIMMY MALGET Work Class: P/M/E Issue Date: 12/27/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/26/2017 Address: 1657 Amante Ct Carlsbad, CA 92011-4041 IVR Number: 1066 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 01/10/2017 BLDG-43Air 009041·2017 Scheduled Jonathan West Incomplete Cond./Fumace Set Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Final 009042-2017 Passed Jonathan West Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Mechanical Final Yes BLDG-Electrical Final Yes January 10, 2017 Page 1 of 1 . CERTIFICATE OF INSTALLATION CF2R-MOf-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of8) Project Name: 1657 Amante Ct. Enforcement Agency: City of Carlsbad Permit Number: PENDING Dwelling Address: 1657 Amante Ct. City: Carlsbad Zip Code: 92011 ~------ A. General Information 01 Dwelling Unit Name 1657 Amante Ct. 02 Climate Zone 7 03 Dwelll"' Unit Total Conditioned Floor 3600 04 Number of Space Conditioning 2 Area (ft2) Systems In this Dwelling Unit. OS Certificate of Compliance Type Prescriptive alterations (CflR-AlT) 06 Method used to Calculate HVAC Loads NotApplicableEquipmentChangeout 07 Calculated Dwelling Unit Sensible This field or section is not applicable 08 Calculated Dwelling Unit Heating Load This field or section is not applicable Cooll"' Load (Btuh) (Btu h) 09 Dwelling Unit Number of Bedrooms 4 r r a ... MCH-Olb Space Conditioning Systems Ducts,.! ans-~ ~ :L .J "'ions -~ ~~-nc~_ ~cri.;::. ~ ~. -~---"""" , -~ -- B. Space Conditioning (SC) System Information r·iERS F1 RC)VIDER 01 02 03 04 OS 06 07 08 09 10 SCSystem SCSystem CFAserved lstheSC Installing a Installing new SC lnstalll"' more Installing Installing Identification or LDcation or Area bythlsSC system a refrigerant system than 40 feet of entirely new entirely new SC Alteration Type Name Served System (ft2) ducted containing components? ducts? duct system? system? system? component? Altered space System 1 location 1 1800 Yes Yes Yes No No No conditioning system ~ --------------------L_ Registration Number: 216-A0476432A-M0100002A-oooo Registration Date/Time: 201~12-30 16:13:07 HERS Provider: CaiCERTS CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version: 2013. Rev 1.008 Schema Version: 2013.1.008 Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 2of8) B. Space Conditioning (SC) System Information 01 02 03 04 OS 06 07 08 09 10 SCSystem SCSystem CFAserved lstheSC Installing a Installing new SC Installing more Installing Installing Identification or Location or Area bythlsSC system a refrigerant system than 40 feet of entirely new entirely new SC Alteration Type Name Served System (ft2) ducted containing components? ducts? duct system? system? system? component? Altered space System 2 location 2 1800 Yes Yes Yes No No No conditioning system C. Space Conditioning (SC) System Alterations Compliance Information System Altered Identification Heating Heating or Name System Type Component This field N h . I or Thisfaeld o eatm . System 1 I Central gas I g section 1s or section componen is not furnace t altered n?t appbcabl applicable e - This field c I I No heatlll81 ~ . This field System 2 I entra gas sectiOn IS or section componen is not furnace t altered n?t appbcabl applicable e Registration Number: 216-A0476432A-M0100002A-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance Central splitAC Central splitAC :11-' _I: All new I cooling components All new cooling components 'l\. A' "" I ~ SEER 14 SEER 14 Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 ill " Setback Setback ,. New or Replaced New _,uct Duct length R-Value LTE40Ft I R6 LTE40Ft R6 I Central Fan Integrated (CFI) Ventilation System Status Nota CFI system Nota CFI system HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans D. Installed Heating Equipment Information This section does not apply to this project. E. Installed Cooling Equipment information Condenser or Packase Unit Condenser or System Identification or Name Cooling Efficiency Type Condenser ... , CDndenser or Cooling Efficiency I Packase Unit Packase Unit Value Manufacturer Model Number Packase Unit Serial Number System 1 SEER 14 System 2 SEER 14 Notes: F. Extension of Existing Duct System, t::rPat;..'11111 G. Installed Duct System information H. Installed Air Filter Device Information Registration Number: 216-A0476432A-M0100002A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance RHEEM WA1442WJ1NA W191636418 RHEEM WA1436WJ1NA W191636967 This section does not apply to this project. This section does not apply to this project. Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CF2R-MCH-01-E (Pase3of8) System Rated Coollns Condenser Rated capacity at Deslsn Nominal capacity Conditions (BTUH) (ton) 42000 3.5 36000 3 HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans 1. Air Filter Device Requirements Registration Number: 216-A0476432A-M0100002A-oooo CA BuHding Energy Efficiency Standards -2013 Residential Compliance This section does not apply to this project. I Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CF2R-MCH-01-E (Page4of8) I HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans J. HERS Verification Requirements 01 I 02 I 03 I 04 I I I I MCH20 I Exemption System I SCSystem I Fn>m Duct Duct Identification or Location or Area Leakage Leakage Name Served Requirements Test System 1 I Location 1 I No Yes exemptions System2 I Location2 I No Yes exemptions Notes: Registration Number: 216-A0476432A-M0100002A-oooo CA Building Energy Efficiency Standards-2013 Residential Compliance -----------·· ·----------- OS 06 07 MCH21 MCH22 Exemption from Minimum R-Yaluefor Ducts In Ducts Located AHUFan Conditioned In Cond Space Efficacy Space Verification (W/cfm) No I No I No I Exemption No I No I No I -.. Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CF2R-MCH-01-E (Pale 5 of8) 08 09 10 MCH23 MCH25 MCH28 AHU Airflow Rate I Refrigerant I Return Duct Design (cfm/ton) Charge Table 150.0-C or D No I No I No No I No I No HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION CF2R-MCH.01-E Space Condltlonlns Systems, Ducts, and Fans (Page 6of8) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heattns Equipment 01 02 03 04 OS Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections 1SO.O(i), 110.2(b). Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 1SO.O(h)1 and 2). Furnace Temperature Rise: Central forc:ed-ak heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet-to-outlet temperature.r'tSe specification. see Section 1SO,O(h)4. Standby losses and Pilot lights: Fan-type CPntralfumac.iYJJtiRtot Coollns Equipment 06 07 08 09 Equipment Efficiency: All cooling equipment Regulations. th~i? e~nSequirepnts~ee 11va"t seE7 1E2(a~d the Appliance Efficiency Refrigerant line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 1SO.O(j)2 and 3, and Section 1SO.O(m)9. Condensing Unit location: Condensing units shall not be placed within five (S) feet of a dryer vent outlet. See Section 1SO.O(h)3A. Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 1SO.O(h)1 and 2. Air Distribution System Ducts, Plenums and Fans 10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section lSO.O(m)l. Registration Number: 216-A0476432A-M0100002A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of8) K. Space Conditioning Systems, Duds and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be appllc:able to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. 11 Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or endosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.L4.3.8. Heat Pump Thermostat 12 I A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 13 I The thermostat shall be installed in accordance with the manufacturers published installation specifications 14 I First stage of heating shall be assigned to heat pump heating. 15 I Second stage back up heatingSf:l~ll be set to come.on.onfywhe.n the indsor se~ tem~~!~!url!~~nn!?t~..!! ... rnet. The responsible person signature on this compllanc' Registration Number: 216-A0476432A-M0100002A-OOOO CA Building Energy Efficiency Standards -2013 Residential Compliance Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION Space Condltlonlftl Systems, Ducts, and Fans Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation Is accurate and complete. Documentation Author Name: Angle Velluto Company: The Energuy CA LlC Address: 1215 K St., 17th Floor City/State/Zip: Sacramento CA 95814 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The Information provided on this Certificate of lnstaUation is true and correct. Documentation Author Signature: Signature Oate: 2016-12-30 16:08:15 CEA/ HERS Certification Identification (if applicable): Phone: 877-600-0123 CF2R-MCH..01-E (PageS of8} 2. I am eligible under Division 3 oft~e 8Usirti!Ss and Professloi'IS Code In the applicable classification to accept respoi'ISibllity for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identffted on this Certlfi e of Installation, and attest to the declarations In this statement (responsible builder/installer), otherwise I am an authorized representative of the respGIISI.,Ie builder/Installer. .8. . · · , fS 1. The constructed or installed features, mat. erlals, ents or ufact. ur . nstalla. . . .·.. . . d . this ·. . . . ¢. lnstallati o· . . . to ... licable codes and regulations, and the lr'tStallation conforms to the requirements given on th ns and lficatl d the en em . · · · I reviewed a copy of the Certificate of Compllan d by the . , . . . · . ulr · .· en . · ,pe o . . uct, ~I 'Ilion identified on this Certificate of Installation, and I have ensured that the requirem pply to the coi'IStruction or installation have been met. 3. 4. I will ei'ISure that a registered copy of this Certificate of lation shJt.ol p~, or ~e a'iable wit~ bu~ prmils) islui!fl toihe Uatng, E mal;ivailable to the enforcement agency for all applicable Inspections. I understand that a registered copy o this certfflca\e olbiftall~io" Is ril(uired to be incluled~th"bbfdocuNentation th\'<uilder provid~ l'o the building owner at occupancy. 5. Responsible Builder/Installer Name: Wes Guthrie Company Name: (lnstatlkigSUbColitractor or General Contractor or Builder/owner) GUTHRIE AND SONS Address: 3914 HICOCK ST City /State/Zip: SAN DIEGO CA 92110 Position With Company (Tli:le): ADMIN CSLB Ucense: 875279 Phone: 619-269-3013 Date Signed: 2016-12-30 16:13:07 Digitally signed by ca/CERTS. This digital signature is provided in order to secure the content of this registered document. and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0476432A-M0100002A-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTAUATION CF2R-MOf-01-E Space Condltlonlns Systems, Ducts, and Fans (Pagel of B) Project Name: 1657 Amante Ct. Enforcement Agency: City of Carlsbad Permit Number: PENDING Dwelllns Address: 1657 Amante Ct. City: carlsbad Zip Code: 92011 A. General Information 01 Dwelllns Unit Name 1657 Amante Ct. 02 Climate Zone 7 03 Dwellfns Unit Total Conditioned Floor 3600 04 Number of Space Condition Ins 2 Area (ttl) Systems In this Dwellfns Unit. OS Certificate of Compliance 'TYPe Prescriptive alterations (CF1R-ALT ) 06 Method used to calculate HVAC Loads NotApplicableEquipmentChangeout 07 calculated Dwelllq Unit Sensible This field or section is not applicable 08 calculated Dwelllns Unit Heatlns Load This field or section is not applicable Coollns Load (Btuh) (Btuh) 09 Dwelllns Unit Number of BedrQQms 4 .ir"' r"" I r-- MOI-01b Space COnditioning Systems Ducts~-4E-i~ ~~ons • ~l ~~ r'lC _ ' -""""' ~ ---, -c~· B. Space Conditioning (SC) System Information t·"'i f.: R 5 F'f~()ViDER 01 02 03 04 SCSystem SCSystem CFAseNed tstheSC Identification or Location or Area bythlsSC system a Name Served System (ttl) ducted system? System 1 Location 1 1800 Yes ... Registration Number: 216-A0476432A-M0100002A-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance OS 06 07 lnstalllns a lnstalllns new sc lnstalllns more refrigerant system than 40 feet of contain ins components? ducts? component? Yes Yes No --- Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 08 09 10 lnstalllns lnstalllns entirely new entirely new sc Alteration 'TYPe duct system? system? Altered space NO No conditioning system HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION CF2R-MCH..01-E Space Condltlonlns Systems, Ducts, and Fans (Page 2 of8) B. Space Conditioning (SC) System Information 01 02 03 04 OS 06 07 08 09 10 SCSystem SCSystem CFAserved lstheSC Installing a lnstalllns new sc lnstalllns more Installing lnstalllns Identification or Location or Area bythlsSC system a refrigerant system than 40 feet of entirely new entirely new SC Alteration Type Name Served System (tr) ducted containing components? ducts? duct system? system? system? component? Altered space System 2 location 2 1800 Yes Yes Yes No No No conditioning system --------------L___ ------ C. Space Conditioning (SC) System Alterations Compliance Information System Altered Identification Heatlns Heattns or Name System Type Component This field Nh 'I or Thisf~eld o eatm . . System 1 I Central gas I g sect1on 1s or section componen is not furnace t altered n?t appbcabl applicable e - This field No heating I or . This field System 2 ( Central gas I sect1on IS or section componen is not furnace t altered n?t apphcabl applicable e Registration Number: 216-A0476432A-M0100002A-OOOO CA Building Energy Effidency Standards -2013 Residential Compliance Central splitAC Central splitAC .- All new I cooling components All new cooling components " ,. s ·" ., s SEER 14 SEER 14 Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 "' " Setback Setback " New or Replaced New tbuct Duct Length R-Yalue LTE40Ft I R6 I LTE40Ft R6 Central Fan Integrated (CFI) Ventilation System Status Nota CFI system Nota CFI system HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 I CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans D. Installed Heating Equipment Information This section does not apply to this project. E. Installed Cooling Equipment Information Condenser or Package Unit Condenser or System Identification or Name Cooling Efficiency Type Condenseror I Co-or Cooling Efficiency I Package Unit Package Unit Value Manufacturer Model Number Package Unft Serial Number System 1 SEER 14 System 2 SEER 14 Notes: F. Extension of Existing Duct System, t.: .... ,. G. Installed Duct System Information H. Installed Air Filter Device Information Registration Number: 216-A0476432A-M0100002A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance RHEEM WA1442WJ1NA W191636418 RHEEM WA1436WJ1NA W191636967 This section does not apply to this project. This section does not apply to this project. Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CF2R-MCH-01-E (Page3of8) System Rated Cooling Condenser Rated capacity at Design Nominal capacity Conditions (BTUH) (ton) 42000 3.5 36000 3 HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 aRTIFICATE OF INSTALLATION Space Condltlonlns Systems, Ducts, and Fans 1. Air Filter Device Requirements Registration Number: 216-A0476432A-M0100002A-OOOO CA Building Energy Efficiency Standards -2013 Residential Compliance This section does not apply to this project. I Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CFZR·MOI..Ol-E (Page4of8) I HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans J. HERS Verification Requirements 01 J 02 l 03 J 04 I MCH20 I Exemption System I SCSystem From Duct Duct Identification or Location or Area Leakage Leakage Name Served Requirements Test System 1 I Location 1 I No Yes exemptions System 2 Locatlon2 No Yes exemptions Notes: Registration Number: 216-A0476432A-M0100002A-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance OS 06 07 MCH21 MOI22 Exemption from Minimum R-Valuefor Ducts In Ducts Located AHUFan Conditioned In Cond Space Efficacy Space Verification (W/cfm) No No No Exemption No I No I No I -.. Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CF2R-MOI-01-E (Pale 5 of8) 08 09 10 M0123 MCH25 MCH28 AHU Airflow Rate Refrigerant I Return Duct Design (cfm/ton) Charge Table 150.0-C or D No No I No No I No I No • HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION CFZR-MCH-Ql-E Space Condition Ins Systems, Ducts, and Fans (Pap6 of8) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. HHtlns fqulprnent 01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections lSO.O{i), 110.2(b). 03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 1SO.O(h)1 and 2). 04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet-to-outlet temperaturedse spedfication. See Section 1SO.O{b)4. OS Standby Losses and Pilot Lights: Fa(t-type central turriac.., r, ~ave ---r"". ·r-on 110. an~ctio~0.2(d). --· !"''-; Coolln&Equlpment ~ ,tt.....CI ,.._ = ~~ .::l. IL ... 06 Equipment Efficiency: All cooling equipment m eet th1Jllti"E' e~c;requirell'"t~eo uvfnt ~ 1f2(a~d the Appliance EffiCiency Regulations. · '~ -> ~ 07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3, and Section 1SO.O(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 1SO.O(h)3A. 09 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 1SO.O(h)1 and 2. Air Distribution System Ducts, Plenums and Fans 10 Insulation: In all cases, unless ducts are endosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section 150.0(m)l. Registration Number: 216-A0476432A-M0100002A..()()()() CA Building Energy Efficiency Standards-2013 Residential Compliance Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 I • CERTIFICATE OF INSTALLATION CF2R-MCH-01·E Space Conditioning Systems, Ducts, and Fans (Page 7 of8) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly Installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. 11 Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or endosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 12 I A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 13 I The thermostat shall be installed in accordance with the manufacturers published installation specifications 14 I First stage of heating shall be assigned:to h._t pump heating. 15 I Second stage back up heating shall be set to come on only when the in The responsible person signature on thlscompKanc' Registration Number: 216-A0476432A-M0100002A-QOOO CA Building Energy Efficiency Standards-2013 Residential Compliance Registration Date/Time: 201&12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 • HERS Provider: caiCERTS Report Generated: 2016-12-30 16:07:36 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation Is accurate and complete. Documentation Author Name: Angle Velluto Company: The Energuy CA LLC Address: 1215 K St., 17th Floor City/State/Zip: Sacramento CA 95814 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of california: 1. The information provided on this Certificate of lnstaUatlon is true and correct. Documentation Author Signature: Signature Date: 2016-12-30 16:08:15 CEA/ HERS Certification Identification (if appHcable): Phone: 877-600-0123 CF2R-MCH..Ol-E (PaseBofS) 2. I am eUgible under Division 3 ofthe Business arut Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured delllces for the scope of work.ldentlfied on this Certlflc e of Installation, and attest to the declarations in this statement (responsible buHder/installer), otherwise I am an authorized representative of the respoll$lble builder/Installer. iitf5 t The constructed or Installed features, mat. erials, tomp factur e nstaUatl Is rt of lnstailatl oflilllllillllto iflllllltlicable codes and regulations, and the instaDatlon conforms to the requirements given tm th ns and lficati o the en erne • I reviewed a copy of the Certificate of Compflan r d by the · · 'fie . uir en rpe ofi nS"u. ~llfjon identified on this Certificate of 3. 4. Installation, and I have ensured that the requirem pply to the construction or installation have been met. I will ensure that a registered copy of this Certificate of lation s~ posl;;;i, or ~e aWable wit~ buliill! pefrnlflisJ islutRI for.he llu"ii'Cina. E rna applicable inspections. I understand that a registered copy o this Certftica\e ortrma11a\1o'?i is re(ulred to be inclucfed~th 'lfiidocu~entation th~lder plbvid s. •a liable to the enforcement agency for all the building owner at occupancy. Responsible Builder/Installer Name: WesGuthrie Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) GUTHRIE AND SONS Address: 3914 HICOCK ST City/State/Zip: SAN DIEGO CA 92110 Responsible Builder/Installer Signature: Position With Company (Title): ADMIN CSLB Ucense: 875279 Phone: 619-269-3013 Date Signed: 2016-12-30 16:13:07 Digltsl/y signed by CaiCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0476432A-M0100002A-OOOO CA Building Energy Efficiency Standards -2013 Residential Compliance Registration Date/Time: 2016-12-30 16:13:07 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 HERS Provider: CaiCERTS Report Generated: 2016-12-30 16:07:36 ------·----------------------------------------------