HomeMy WebLinkAbout1683 FISHERMAN DR; ; CB050588; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
05-18-2005 Residential Permit Permit No: CB050588
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
1683 FISHERMAN DR CBAD
RESDNTL Sub Type: SFD Status:
Parcel No:
Valuation:
Occupancy Group:
05/18/2005
# Dwelling Units:
Bedrooms:
Project Title:
2150811100
$384,552.00
1
4
LA SUVERA PLAN 4
Lot#:
Construction Type:
Reference #:
11
VN
CT00-22
Structure Type: SFD
Bathrooms: 3.5
Applied:
Entered By:
Issued:
Inspect Area:
Orig PC#:
3990 SF LIVING, 704 SF GARAGE, 45 SF PORCH Plan Check#:
Applicant:
CALCO WEST FINANCIAL INC.
310 VIA VERA CRUZ 92078
510-6419
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$1,424.36
$0.00
$925.83
$0.00
$0.00
$38.46
$2,436.00
$0.00
$0.00
$0.00
$0.00
$12,780.00
$0.00
$0.00
$0.00
$0.00
$2,999.00
05/8
$0.00
$0.00
Owner:
CRAFTSMAN CARLSBAD I L L C
1195 LINDA VISTA DR #G
SAN MARCOS CA 92078
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFD Payoff Fee
PFF
PFF (CFD Fund)
License Tax
License Tax (CFD Fund)
Traffic Impact Fee
Traffic Impact (CFD Fund)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnLieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
ISSUED
12/30/2004
SB
Plan Approved:
05/18/2005
PC04-152
$0.00
$160.00
$2,461.00
$2,550.12
$6,998.85
$0.00
$0.00
$0.00
$660.00
$0.00
$0.00
$238.00
$60.00
$85.00
$0.00
$0.00
$0.00
$0.00
$2,278.00
$0.00
$36,094.62
Total Fees: $36,094.62 Total Payments To Date: $0.00 Balance Due: $36,094.62
Inspector: :I: J •
86GO 051':i.il/05 0002 OJ
c:t:::.:.F~
Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition~ of fees, dedications, reseivations, or other exactions hereafter collectively
referred to as "fees/exactions.~ You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f fhih h hihh
."\'1 ,1,:..
3609-{,, ~2
.tH~!!l~~w~'sfti~i~~~~
Date: 07/07/2006
Permit#: CB050588 Permit Type: RESDNTL
Project Name: LA SUVERA PLAN 4 Sub Type: SFD
3990 SF LIVING, 704 SF GARAGE, 45 SF PORCH
Address: 1683 FISHERMAN DR Lot: 11
Contact Person: GLEN
Sewer Dist: CA
Phone: 7606447665
Water Dist: CA
··························································································································································
Inspected Date
By: Inspected: Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __
···························································································································································
Comments: ______________________________ _
c111 ,r ca,1111111
~ ·; Flnal Bulldlna Inspection
-"'!'·· '
Dept: Building Eng· efing Planning CMWD St Lite Fire
Plan Check#:
Permit#:
Project Name:
Address:
CB050588
LA SUVERA PLAN 4
3990 SF LIVING, 704 SF GARAGE, 45 SF PORCH
1683 FISHERMAN DR
Contact Person: GLEN Phone: 7606447665
Water Dist: CA Sewer Dist: CA
Date: 07/07/2006
Permit Type: RESDNTL
Sub Type: SFD
Lot: 11
··························································································································································
Inspected
By:. f2tJ
Date
Inspected:
Inspected Date
7 /I U ~pproved: ~isapproved: __
By: -----------Inspected: _____ Approved: ___ Disapproved: __
Inspected Date
By: Inspected: _____ Approved : ___ Disapproved: __ ...........................................................................................................................................................
Comments: ______________________________ _
, .,
m. City of Carlsbad Bldg Inspection Request
. For: 03/20/2006
F
Permit# CB050588 Inspector Assignment: PS ---
Title: LA SUVERA PLAN 4
Description: 3990 SF LIVING, 704 SF GARAGE, 45 SF PORCH
Type: RESDNTL Sub Type: SFD
Phone: 7606447665
~ Job Address:
Suite:
Location:
1683 FISHERMAN DR
Lot 11
Inspector:
APPLICANT CALCO WEST FINANCIAL INC.
Owner: CRAFTSMAN CARLSBAD I L L C
Remarks:
Total Time: Requested By: GLEN
Entered By: CHRITINE
CD Description
39 Final Electrical
~ Comment
---·---------
Comments/Notices/Hold
Associated PCRs/CVs Original PC#
lns11ection Histo!Y
Date Description Act lnsp Comments
12/19/2005 82 Drywall/Ext Lath/Gas Test AP BN
12/14/2005 16 Insulation WC PS
12/14/2005 84 Rough Combo WC PS
12/13/2005 16 Insulation AP PS
12/13/2005 84 Rough Combo AP PS
12/12/2005 16 Insulation CA PS RESET FOR TUES.
12/12/2005 84 Rough Combo CA PS
12/08/2005 84 Rough Combo co PS OK TO INSULATE
12/06/2005 84 Rough Combo CA PS
12/05/2005 84 Rough Combo CA PS BY GLENN
11/22/2005 13 Shear Panels/HD's AP BN
10/12/2005 65 Retaining Walls WC PC wrong permit
09/15/2005 15 Roof/Reroof AP PS
09/14/2005 15 Roof/Reroof co PS OK TO DRY IN
09/13/2005 15 Roof/Re roof NS PS ROLLED TO 9/14
09/12/2005 15 Roof/Re roof CA PS BY FRAMER
09/06/2005 15 Roof/Reroof CA PS BY GLEN
09/02/2005 15 Roof/Reroof CA PS ROLL TO 9-6.
06/17/2005 81 Underground Combo AP PS
PREFERED CONSTRUCTION
INSPECTIONS, INC
4888 Ronson Court, "G"
San Diego, CA. 92111 --¥6
INSPECTION REPORT JOB NO.: 3740
(858) 576-9110
Fax (858) 576-7028
WORK PERFORMED: POST TENSION STRESSING INSPECTION
JOB ADDRESS: 1683 FISHERMAN DRIVE
JOB NAME: LA SUVERA
DESCRIBE MATERIAL:
1/2" DIAMETER, 7 STRAND PT CABLES
GAUGE #702, CALIBRATED 7/5/05
PERMIT NO.: CB05-0588
PLAN FILE NO.:
ARCHITECT:
ENGINEER: DAVIDSON REINFORCING COMPANY
GENERAL CONTRACTOR: CRAFTSMAN DEVELOPMENT
CONTRACTOR: DAVIDSON REINFORCING COMPANY
07/26 Inspected the stressing of post tension tendons in slab on grade for lot #11.
Mesaure/record elongations and monitored gauge pressure during post
tensioning. Cables were stressed to proper elongation and gauge pressure. Work
observed is in accordance with the approved plans and specifications. Arrived on
jobsite at 6:45 AM, left at 8:30 AM.
INSPECTOR: G,/..-
DATE: 7/26/2005
TOM PAYNE
CERT. NO. : 0847166-81
,s:Nllz : · · LA S dr/elA •· · : . . , · . . .... :·,l(Ji$ NUMBER ·
r. ~ ·· ...... · If · f d"D ) · GAl1GE tmtmm . 7-0 2'....
GAUGE l'USSURE ---------
..
~ON
CAJJLE Dmll:l'.llf, FULL 11 . '111,J.. 12 mw. . ltOTJ
1 i./ 711-. t:l!'l2 . •.
21 .
22 ' _. I '! I flf/.
3 .. .} j ~ ti 'lit .
23
. lj / .. 1/.
24 -~ ''
' 17 5.:. ...
· 25
.. ·. t1 '1/// l/7,,, . . ·>.
7 cV~ ~;_;'/;; ..
27
J. .. 28 I J1,1 11 :;J
J . ' Ji It / .
29 ,> ~ . I
J . 30 I .'/ -. ( ,-
'J I ~ I
31 .
32
I ' 33
..
34 . .
I 35
..
36 ,.
37 .1 · .
' '·· ~ 38
'
. . .. ..
39 ..
-·
40.
PkEFERED CONSTRUCTION INSPECTIONS, INC
4888 Ronson Court, "G"
San Diego, CA. 92111
(858) 576-9110
Fax (858) 576-7028
TEST REPORT JOB NO.: 3740
JOB NAME: LA SUVERA
JOB ADDRESS: 1683 FISHERMAN DRIVE
OWNER: CRAFTSMAN DEVELOPME
CLIENT: CRAFTSMAN DEVELOPMENT
ARCHITECT:
INSPECTOR: DALE REGLI
FIELD CONCRETE
SAMPLE OF:
MTXNO.:
PROPORTIONS:
ADMIXTURE:
TYPE OF CEMENT:
2533001
5 SACK
CONCRETE SUPPLIER: HANSON AGGREGATES
CONTRACTOR:
ENGINEER:
COASTAL CONCRETE
DAVIDSON REINFORCING COMP
BUILDING AUTHORITY: CITY OF CARLSBAD
PERMIT NO. CB05-0588 PLAN FILE NO. :
LOCATION OF SPECIMEN LOT# 11 NORTHEAST CORNER
IN JOB OR STRUCTURE:
MADE BY: DALEREGLI
SLUMP: 5"
DATE MADE: 6/20/2005
DA TE RECEIVED: 6/22/2005
TICKET NO. 821108
LABORATORY TEST DATA
AGE TESTED:
SPECIMEN MARKINGS:
DA TE TESTED:
DIAMETER-AREA-SQ. IN.:
ULTIMATE LOAD -LBS:
UNIT STRESS -PSI
SPECIFIED STRENGTH
AT 28 DAYS -PSI:
DISTRIBUTION:
CRAFTSMAN DEVELOPMENT
COASTAL CONCRETE
JO DAYS
82012
6/30
28.28
46500
1640
DAVIDSON REINFORCING COMPANY
CITY OF CARLSBAD
28DAYS
~(;
z#DAYS HDAYS
82013 82014
7/18 8/19
28.28 28.28
64000 71500
2260 .&?-tf 2530
2500
TEST BREAK IN USUAL CONFIGURATION WITH UNBONDED CAPS UNLESS NOTED OTHERWISE.
TESTMETHODS-ASTM ,1 C39: 0 Ct73: 0 C23!: liil Cl231:
[J Cl72: 0 Cl43: D Cl38:
' ' ' ' " • ' ' ' '
[]
TYPE OF FRACTURE
m f;l ~ LJ LJ LJ
D D [J
'' '' '' '' '' '' D
,•
July 11, 2006
TO: Mike Burzinski, fax: (760) 510-6712
Bob Wojcik, Deputy City Engineer
Christine Wauschek, Building Department
Pete Dreibelbis, Senior Building Inspector
Gary Goodman, Construction Inspector
Pat Kelley, Building and Code Inspector
Michele Masterson, Management Analyst
FROM: Michael Elliott, Landscape Architect Consultant to the City of Carlsbad
PROJECT: La Suvera Lot 9 -1675 Fisherman Drive
Lot 11 -1683 Fisherman Drive CB 050588
The following items were noted as deficient and in need of correction:
Lot 9 -1675 Fisherman Drive
A request for inspection was not received from the City; however when arriving on site, the
contractor requested that this lot be inspected.
1. Provide irrigation to the front yard tree per plan requirements.
2. Remove all trash and debris from slope areas.
3. Existing grades shown to remain were modified outside the rear yard fence within
sections A-2 and A-3. The contractor is directed to provide irrigation and planting in all
graded areas and to provide fire suppression measures in all native slope areas per the
Landscape Manual as follows: (It is recommended that the contractor obtain a landscape
architect to provide planting plans insuring that appropriate low fuel plants are used.)
Manufactured Slope Fire Protection (see Appendix F.2)
Pertains to man-made slopes abutting high risk fire areas as described under Section JI
C.1
Section A-1 -Measured horizontally 20' outward from the outlying edge of
structure( s ).
Landscaping in this area meets requirements of the Landscape Manual.
Section A-2 -Measured horizontally 20' outward from the outlying edge of Section
A-
a. Planted with low water use naturalizing plant species known to have low fuel
characteristics.
b. No trees allowed.
c. Irrigated.
Section A-3 -Measured outward from the outlying edge of A-2 to include the
remainder of the area between Section A-2 and high risk fire areas as described
La Suvera-Lots 9 & 11
]:iµal l,andscape Inspection
July 11, 2006
Page2
under Section II C. Horizontal distance from the structure(s) to untreated high risk
areas shall not be less than 60'.
a. Planted with low water use naturalizing plant species known to have low fuel
characteristics.
b. Trees are allowed but shall not be planted closer than 20' apart.
c. Irrigated.
Wild-land Fire Suppression (See Appendix F.2)
Pertains to areas where removal of environmentally sensitive native vegetation is
restricted within the fire sections.
Section B-1 -Measured 20' horizontally from the outlying edge of the structure(s)
toward the environmentally restricted area as defined by the city.
Landscaping in this area meets the Landscape Manual requirements.
Section B-2-Measured horizontally 20' outward from the outlying edge ofB-1.
a. Removal of "high fuel species" as listed in Appendix F. I.
b. Removal by selective pruning ofup to 60% of the volume of the "moderate fuel
species" as listed in Appendix F. I.
c. Replanting with naturalizing low fuel species.
d. Trees and large tree form shrubs (e.g. Oaks, Sumac, Toyon) which are being
retained shall be pruned to provide clearance equal to three times the height of
the surrounding under-story plant material or 6', whichever is higher. Dead and
excessively twiggy growth shall also be removed.
e. Irrigated.
Section B-3 -Measured horizontally 20' outward from the outlying edge of Section
B-2. The outer edge of B-3 shall extend horizontally to a point at least 60' from
structures.
a. Removal of "high fuel species" as listed in Appendix F. I.
b. Removal by selective pruning ofup to 40% of the volume of the "moderate fuel
species" as listed in Appendix F. I.
c. Trees and larger tree form shrubs ( e.g. Oaks, sumac, Toyon) which are being
retained shall be pruned to provide clearance equal t three times the height of
the surrounding under-story plant material or 6', whichever is higher. Dead and
excessively twiggy growth shall also be removed.
d. Non-irrigated.
Debris and trimmings produced by thinning shall be removed from the site or shall be
converted to mulch by a chipping machine and evenly dispersed over the area to a
maximum depth of 4".
Lot 11 -1683 Fisherman Drive CB 050588
I. Provide irrigation to the front yard tree per plan requirements.
La Suvera -Lots 9 & 11
J:inal I,andscape Inspection
July 11, 2006
Page 3
2. Install Myoporum parvifolium on the rear slope in areas per plan between Gazania at 12"
on center.
3. Install additional Gazania at 12" on center on the rear slope in areas per plan where voids
exist.
4. Install vacuum breaker on all valves per plan requirements.
5. Install 12" pop-up sprinklers at the top of slope and insure the Rainbird SAM-PRS model
is used per plan requirements.
6. Install check valves on any sprinkler where low head drainage occurs.
7. Repair broken lateral at the bottom of slope.
8. Install one additional sprinkler at the bottom of slope at the southwest end.
9. Remove all trash and debris from slope areas.
I 0. Existing grades shown to remain were modified outside the rear yard fence within
sections A-2 and·A-3. The contractor is directed to provide irrigation and planting in all
graded areas and to provide fire suppression measures in all native slope areas per the
Landscape Manual as follows: (It is recommended that the contractor obtain a landscape
architect to provide planting plans insuring that appropriate low fuel plants are used.)
Manufactured Slope Fire Protection (see Appendix F.2)
Pertains to man-made slopes abutting high risk fire areas as described under Section II
C.l
Section A-1 -Measured horizontally 20' outward from the outlying edge of
structure(s).
Landscaping in this area meets requirements of the Landscape Manual.
Section A-2 -Measured horizontally 20' outward from the outlying edge of Section
A-
a. Planted with low water use naturalizing plant species known to have low fuel
characteristics.
b. No trees allowed.
d. Irrigated.
Section A-3 -Measured outward from the outlying edge of A-2 to include the
remainder of the area between Section A-2 and high risk fire areas as described
under Section II C. Horizontal distance from the structure(s) to untreated high risk
areas shall not be less than 60'.
a. Planted with low water use naturalizing plant species known to have low fuel
characteristics.
La Suvera -Lots 9 & 11
Fi.nal Landscape Inspection
July 11, 2006
Page4
b. Trees are allowed but shall not be planted closer than 20' apart.
c. Irrigated.
Wild-land Fire Suppression (See Appendix F.2)
Pertains to areas where removal of environmentally sensitive native vegetation is
restricted within the fire sections.
Section B-1 -Measured 20' horizontally from the outlying edge of the structure(s)
toward the environmentally restricted area as defined by the city.
Landscaping in this area meets the Landscape Manual requirements.
Section B-2 -Measured horizontally 20' outward from the outlying edge of B-1.
a. Removal of "high fuel species" as listed in Appendix F. I.
b. Removal by selective pruning ofup to 60% of the volume of the "moderate fuel
species" as listed in Appendix F. I.
c. Replanting with naturalizing low fuel species.
d. Trees and large tree form shrubs ( e.g. Oaks, Sumac, Toyon) which are being
retained shall be pruned to provide clearance equal to three times the height of
the surrounding under-story plant material or 6', whichever is higher. Dead and
excessively twiggy growth shall also be removed.
e. Irrigated.
Section B-3 -Measured horizontally 20' outward from the outlying edge of Section
B-2. The outer edge ofB-3 shall extend horizontally to a point at least 60' from
structures.
a. Removal of"high fuel species" as listed in Appendix F.l.
b. Removal by selective pruning ofup to 40% of the volume of the "moderate fuel
species" as listed in Appendix F. I.
c. Trees and larger tree form shrubs (e.g. Oaks, sumac, Toyon) which are being
retained shall be pruned to provide clearance equal t three times the height of
the surrounding under-story plant material or 6', whichever is higher. Dead and
excessively twiggy growth shall also be removed.
d. Non-irrigated.
Debris and trimmings produced by thinning shall be removed from the site or shall be
converted to mulch by a chipping machine and evenly dispersed over the area to a
maximum depth of 4".
City of Carlsbad Bldg Inspection Request
For: 07/07/2006
Permit# CB050588 Inspector Assignment: PS ---
Title: LA SUVERA PLAN 4
Description: 3990 SF LIVING, 704 SF GARAGE, 45 SF PORCH
Type: RESDNTL Sub Type: SFD
Job Address: 1683 FISHERMAN DR
Suite: Lot 11
Location:
APPLICANT CALCO WEST FINANCIAL INC.
Owner: CRAFTSMAN CARLSBAD I L LC
Remarks:
Total Time:
Phone: 7606447665
Inspector: J\,J\
Requested By: GLEN
Entered By: CHRISTINE
CD Description Act Comment
19 Final Structural a_~~~~~~~
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
-----
-------------------------------
Comments/Notices/Hold
Associated PCRs/CVs Original PC#
lns12ection Histo!}:'.
Date Description Act lnsp Comments
03/20/2006 39 Final Electrical PA PC EMR
12/19/2005 82 Drywall/Ext Lath/Gas Test AP BN
12/14/2005 16 Insulation WC PS
12/14/2005 84 Rough Combo WC PS
12/13/2005 16 Insulation AP PS
12/13/2005 84 Rough Combo AP PS
12/12/2005 16 Insulation CA PS RESET FOR TUES.
12/12/2005 84 Rough Combo CA PS
12/08/2005 84 Rough Combo co PS OK TO INSULATE
12/06/2005 84 Rough Combo CA PS
12/05/2005 84 Rough Combo CA PS BY GLENN
11/22/2005 13 Shear Panels/HD's AP BN
10/12/2005 65 Retaining Walls WC PC wrong permit