HomeMy WebLinkAbout1685 DOCENA RD; ; CB043890; PermitJob Address
Permit Type
Parcel No
Valuation
Occupancy Group
# Dwelling Units
Bedrooms
Project Title
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No CB043890
Building Inspection Request Line (760) 602-2725
1685DOCENARDCBAD
RESDNTL Sub Type RAD ' Status ISSUED
2159100400 Lot# 0 Applied 10/15/2004
$12,05900 Construction Type NEW Entered By KMT
Reference # Plan Approved 10/15/2004
0 Structure Type Issued 10/15/2004
0 Bathrooms 0 Inspect Area
WHIDDON RES- CONVRT 1/2 BTH TO Orig PC#
3/4, ADD CLOSET, ADD FULL BATH @ 2ND STRY Plan Check#
Applicant
WHIDDON DAVID C&JANET M
Owner
WHIDDON DAVID C&JANET M
1685DOCENARD
CARLSBAD CA 92009
760-476-9463
1685DOCENARD
CARLSBAD CA 92009
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$12279 Meter Size
$0 00 Add'l Reel Water Con Fee
$79 81 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$1 21 PFF
$0 00 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 Traffic Impact (CFD Fund)
$0 00 Sidewalk Fee
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Housing Impact Fee
$0 00 Housing InLieu Fee
Housing Credit Fee
SO 00 Master Drainage Fee
$0 00 Sewer Fee
Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$5500
$2000
$21 50
$000
$000
$000
$000
$000
$000
$300 31
Total Fees $300 31 Total Payments To Date $0 00 Balance Due
3343
$300 31
SOC2 Ol —
300« 31
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must,
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review set aside, void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
1 PROJECT INFORMATION
FOR OFFICE USE ONLY
PLAN CHECK NO
EST VAL
Plan Ck Deposit
Validated By .
Date /£)//5/0 I/
Address (include Bldg/Suite #)Business Name (at this address)
Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units
Assessor's Parcel #Existing Use Proposed Use
-^Description of Wort
Cs£>n.\r&r-(*~ f Oi
2 CONTACT PERSON (if different from applicant)
SQ FT f
•(
#of Stori # of Bedrooms # of Bathrooms
Name Address
?3 APPLICANT jp Q Contractor Q Agent for Contractor Owner
City
Agent for Owner
State/Zip Telephone Fax*
Name Address City State/Zip Telephone #
Name Address City State/Zip Telephone #
5 CONTRACTORI- COMPANY NAME ' ? '•"""
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basrs for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500)1
Name
State License ff
Address
License Class
City State/Zip
City Business License #
Telephone #
Designer Name
State License #
Address City State/Zip Telephone
6; iXiiWORkERS' COMPENSATION!** - :.'PS|; '**"' '"'"'" ...... ..... I}.,..; -:,s: , '•'••' : -^ ' ' '' "'""""'
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
l~l I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued ,
[~1 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker s compensation insurance carrier and policy number are
Insurance Company _ Policy No __ Expiration Date _
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
r~| CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees
SIGNATURE __ DATE _
OWNER-BUILDER DECLARATION :: m ..... -: ........ "" ,;i;; •- > ,: ; ;;
I hereby affirm that I am exempt from the Contractor's License Law for the following reason
0 I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
J/Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law)
l~l I am exempt under Section _ Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES l~lNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
PROPERTY OWNER SIGNATURE yj$J/Ulffl)'! [lUvU-U. U i
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work) /~\ /)
/J ~/ DATE _
^COMPLETE THIS SECTION^OR/iON-RESIDENTIAL BUILDING PERMITS ONLY? - =
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act' l~l YES l~l NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' l~l YES Q NO
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? O YES fj NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
87 CONSTRUCTIOri LENDJNGSAGENCY 7 7/77' '. . ' ' . *!*" ^ :h " :
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code)
LENDER'S NAME LENDER S ADDRESS
9. APPLICANT CERTIFICATION '" '"**". ^J^; " ' ... •_... :f£ " __. • iii
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenced for a period of 180 djgrs (Section 106 4 4 Uniform Building Code)
'APPLICANT'S SIGNATURE /7fGLfajM~*rr[ UST\.ff&\^~ DATE
WHITE File YELLOW Applicant PINK Finance
City of Carlsbad Bldg Inspection Request
For 12/17/2004
Permit* CB043890
Title WHIDDON RES- CONVRT 1/2 BTH TO
Description 3/4, ADD CLOSET, ADD FULL BATH @ 2ND STRY
Inspector Assignment JM
Sub Type RAD
1685 DOCENARD
Lot
Type RESDNTL
Job Address
Suite
Location
OWNER WHIDDON DAVID C&JANET M
Owner WHIDDON DAVID C&JANET M
Remarks
Phone 6197236700
Inspector
Total Time
CD Description
19 Final Structural
Requested By MIC
Entered By JANEAN
Act Comment
Associated PCRs/CVs
Inspection History
Date Description
11/22/2004 17 Interior Lath/Drywall
11/19/2004 17 Interior Lath/Drywall
11/19/2004 18 Exterior Lath/Drywall
11/18/2004 14 Frame/Steel/Bolting/Weldmg
11/18/2004 24 Rough/Topout
11/18/2004 34 Rough Electric
11/18/2004 44 Rough/Ducts/Dampers
Act Insp Comments
AP JM
PA JM BATHROOMS ONLY
WC JM
AP JM ok to drywall
AP JM
AP JM
WC JM
Homeowner: David & Janet Whiddon
1685DocenaRd
Carlsbad, CA 92009
Contact Person: Nick Bowman
619-723-6700
BY
OCT 15 2004
City of CARLSBAD
BUILDING DEPT
Existing
bedroom # 5
Existing
Powderroom
11'-10°
o>
5?IO
Bedroom # 5
New shower
added and
Bedroom #5
Closet
5'-5"
t-
0
T<0
J_
Existing
Bedroom #4
2'-4"
3•*
II
!?
2'-4"
3-COQ o>
(O
convert existing closet to
batheroom and add 2 closet to
bedroom #4
00
fort-Load-Bearing Watt Framing
DoorHeader
J J
> ]
J
It
X^
Regular Stud Spat
L -1
h 1"*
ssil
Door
Sole PI
sng
J J , J
f >
\
1
?
r
NOTES TO FRAMING DETAIL
V All joists, rafters, beams, and posts 2" to 4" thick to be No 2 Douglas Fir - Larch or better All timbers 5" and
thicker to be No 1 grade Douglas Fir - Larch or better
2 Trimmer and header joists shall be doubled, or of lumber of equivalent cross section, when the span of the
header exceeds four feet The ends of header joists more than 6 feet long shall be supported by framing
anchors or joist hangers unless bearing on a beam, partition, or wall Tail joists over 12 feet long shall be
supported at header by framing anchors or on ledger strips not less than 2"x 2"
3 Notches on the ends of joists shall not exceed % the joist depth Holes bored in joists shall not be within 2" of
the top or bottom of the joist, and the diameter of any such hole shall not exceed 1/3 the depth of the joist
Notches in the top or bottom of the joist shall not exceed 1/6 the depth and shall not be located in the middle
third of the span Joists framing from the opposite side of a wood girder shall be supported by framing
anchors or on ledger strips not less than 2 "x 2"
WALLS *
1 The maximum height of unbraced 2X4 studs is 10 feet in beanng walls and 14 feet in non-bearing walls
2 The maximum height of unbraced 2X6 studs is 10 feet in bearing walls and 20 feet in non-bearing walls
3 In exterior walls and beanng partitions, any wood stud may be cut or notched to a depth not exceeding 25%
and not exceeding 40% in non-bearing partitions
4 A hole may be bored not to exceed 40% of the width of the stud A hole not exceeding 60% is allowed in
non-bearing partitions or m any wall where the studs are doubled, provided not more than two successive
studs are so bored Bored hole shall not be closer than 5/8" to the edge of the stud Bored holes shall not be
located at the same section as a cut or notch (UBC 2320 11 9)
BRACING
All exterior walls and applicable interior walls shall be braced to resist wind and seismic forces by the use of
either plywood or stucco panels Panel layout shall comply with the following plan
v
ft
TYPICAL
SHEAR WALLS
LAYOUT
>-T
f
AFIELD
NAILING
PLAN
• SHEAR WALLS
ELEVATION
1.
2.
3.
Shear wall panels shall be applied at each end of the braced wall and 25' o c max
Maximum perpendicular distance between braced wall shall not exceed 25'
All required shear panels shall extend from the sill plate to the horizontal diaphragm (roof)
Plywood A minimum 4'0" plywood shear panel of minimum 3/8" CDX with 8d common nails
spaced 6" o c on edges and 12" o c along intermediate supports (field), or
Stucco (cement plaster) A minimum 8' wide stucco panel 7/8" thick applied over approved lath
reinforcement and attached to all studs, top plates, and bottom plates with approved fasteners 6" o c