Loading...
HomeMy WebLinkAbout1694 DOCENA RD; ; CB111056; Permit05-19-2011 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Cogeneration Permit Permit No:CBl 11056 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: 1694DOCENARDCBAD COGEN Sub Type: EVG 2159103,100 . Lot#: 0 Status: $0.00 Construction Type: NEW Applied: Reference #: Entered By: IKEDA RES: INSTALL 40 AMP CIRC Plan Approved: & NEMA 6-50 RECEP FOR ELECTRICAL VEH CHARGER- NO Issued: Inspect Area: Plan Check#: Owner: ISSUED 05/19/2011 JANEAN 05/19/2011 05/19/2011 SUNWEST ELECTRIC INC 3064EMIRALOMAAV 92806 714630-8700 IKEDA 1998 FAMILY REVOCABLE TRUST 11-06-98 1694DOCENARD CARLSBAD CA 92011 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Green Bldg Stands (SB1473) Fee Total Fees: $22.00 Total $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 $1.00 Payments To Date: PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Additional Fees TOTAL PERMIT FEES $22.00 Balance Due: $0.00 $20.00 $0.00 $0.00 $22.00 $0.00 Inspecto FINALAPRROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protSSt imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. ,<& <4[ ,-* Building Permit: A <S^5' 1635 Faraday Ave., Carlsb \S CITY OF 760-602-2717/271? k^ADI CRAH Fax760-602-8£ V^ AK LO DAL/ www.carlsbadca.! J°BADDRESS 1694DOCENAROAD CT/PRQJECTfl LOTfl PHASED tt OF UNFTS tt BEDROOMS .. .. Plan Check No.(LfoUV<O^ppucotion T'-'^-n ad, CA 92008 Est. Value I /O71O'4'^ Plan Ck. Deposit !°v Date ^ j \c\\ \{ SWPPP surrE#/sPACE*/uNmt APN # BATHROOMS TEKAjNT BUSINESS NAME CONSTR, TYPE DESCRIPTION OFWORK: Include Square Feet of Affected Area(s) Install 40A circuit and NEMA 6-50 receptacle for Electrical Vehicle Equipment EXISTING USE PROPOSED USE GARAGE (SF) CONTACT NAME (If Different Fern Applicant) ADDRESS CITY STATE ZIP PHONE FAX EMAIL PROPERT¥OWNERNAME REXIKEDA ADDRESS 1694 DOCENA ROAD CITY STATE ZIP Carlsbad CA 92011 PHONE FAX 760-929-0559 EMAIL A8CH/DESI6NERNA.ME4ADORESS STATEU&» - OCC. GROUP PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRESPRINKLERS YESQ» NCJ | YESnNoQ YES| |HO| | APPLICANT NAME „,Shaun Eastman ADDRESS 3064 E. Miraloma Ave. CITY STATE ZIP Anaheim CA 92806 PHONE FAX 714-678-0083 714-630-8740 EMAIL seastman@sunwestelect.com CONTRACTOR BUS. NAME Sunwest Electric, Inc. ADDRESS 3064 E. Miraloma Ave, CITY STATE ZIP Anaheim CA 92806 PHONE FAX 714-60-8700 714-630-8740 EMAIL seastman@sunwestelect.com STATE UC.# CLASS CITY BUS. UC.# 511697 CIO 1216494 civil penalty of not more than five hundred dollars {$500}). Workers' Compensation Declaration: I hereby affim under penalty tf perjury one of the burning dec/aralrare: LJI have and will maintain a certificate of consent to sell-Insure for workers' compensation as provided by £ l/J I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. My workers' compensation Insurance carrier and policy number are: Insurance Co oMmpuhikhni«ic«coi|. Policy No. MCIMIUIOW Expiration Date """'" Thfe section need nol be completed if the permit Is for one hundred dollars ($100) or less. I I Certificate of Exemption:! certify that in the performance of the work for which IMs permit is Issued, I shall Arfemploy any person in any manner so as to become subject to the Workers' Compensator! Laws of California. WARNING: Failure to secure workers' compensation coverage is untffivMj*«t$MlsurjJ«t In employer to criminal penalties and chril fines up to one hundred thousand dollars {&100.000), In addition to Die cost of compenjatkmrdarfHjjes as'ya^did for In Sadlp^ 3706 oj|JiaUbjLfj3jggraAid_ajlornay's fees. ff< fyiMTRjurrnB BIBMTIIIH: ==^"J^^ *JZ=. -^^ ^*^\~~~~ -^ [7}AGENT DATE r •». /ftereoyaffiraiftsl/amommpffrom Contractor's UcensoLw (a Iho Mowing reason: | [ 1, as ov.ner of the properly or my employees with wages as their cole compensation, will do Die work and the sbucruie is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's sale. If, however, tha bulding or Improvement fe sold within one year of completion, the owner-bu3der will have the burden of proving that lie did not built) or improve for Die purpose of sale). [/I I, as owier of the properly, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business end Professions Code; The Contractor's License Law does not apply to an owner of property who builds or Improves Diereon, and contracts lor such projects with cont/actor(s) licensed pursuant to the Contractor's License Uw). | | I am exempt under Secrjon Business and Professions Code for IMs reason: 1.1 personally plan to provide 8ie major labor and maten'ats forconslrucfon of rjie proposed property hiprovement I lYes I JNo 2.1 (have / have not) signed an application lor a building permit for the proposed work. 3.1 have contracted with (he following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the fotolng person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): S. I will provide some of the v«rk. but I have contacted (hired) the following persons to provide the work indicated {taclude name / address / phone / type of work): ^PROPERTY OWNER SIGNATURE 0AGENT DATE Is the applicant or future building occupant required tosubmil a businessman, scutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 <x 25534 of the Prestey-TannefHazardousSubstanwAccountAct? QYes I IMP Is the applicant or future building occupant retired to obtain a psrma from 8ie a'r pollution control district or alrijyality management district? LZJYes I I No Isttiefac%lol)ecoristructedwilhln1.000feetof8ieouterboundaiy<ifaschoolsrle? LJYes LJtto IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING TH E REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there 1$ a construction lending agency for the performance of (he work this permit Is Issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I hereby authorize representaSve of the Oty of Carlsbad to enterupon the above rnen&ned properly for tepscSonpunposes. I ALSO AGREE TO SAVE JNDEIWff AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERIAT. OSHA: An OSHA permit is required for excavations over SO deep and demoffion or construction of structures over3 stories hheighl EXPIRATION: Every permit Issued by the Building Official under the provisions of this Code sb4JM|ej)£JirJitajion and racome nu5 and void if the building or work authorized by such permit is not commenced wShin 180 days from the date of such pemi^ or if the buMng or work author^ by suehjejT^^ ^APPLICANT'S SIGNATURE ja^^S^^^SSS3—~"~~~" _.--—-—' ~" -/X~~^^ rjATE City of Carlsbad Bldg Inspection Request For: 06/08/2011 Permit* CB111056 Title: IKEDA RES: INSTALL 40 AMP CIRC Inspector Assignment: Description. & NEMA 6-50 RECEP FOR ELECTRICAL VEH CHARGER- NO SERVICE PANEL UPGRADE Type:COGEN Sub Type: EVG Job Address: 1694 DOCENA RD Suite: Lot: 0 Location: OWNER IKEDA 1998 FAMILY REVOCABLE TRUST 11-06-98 Owner: IKEDA 1998 FAMILY REVOCABLE TRUST 11-06-98 Remarks: Phone: 7143188594 Inspectoff1 Total Time: CD Description 34 Rough Electric 39 Final Electrical Requested By: NICK Entered By: CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date Description Act Insp Comments m° r-o< rn£" CT•as m5Q Z oa -o 3> • •>•'.'-4%, ;l^>* •;:•%.&: M?&$& •^tm GENERAL NOTES & SPECIFICATIONS (SHEET 1 OF 2) WORK SPFptFIED HEREIN WORK UNDER THIS SPECIFICATION INCLUDES FURNISHING ALL MATERIAL. LABOR. EQUIPMENT. ETC., AND FINAL CONNECTION TO EQUIPMENT IN ORDER TO PROVIDE THE OWNER WITH A COMPLETE AND PROPERLY FUNCTIONAL ELECTRIC VEHICLE SUPPLY EQUIPMENT. IN GENERAL, THE WORK SHALL CONSIST OF BUT NOT BE LIMITED TO THE FOLLOWING: • FURNISH AND INSTALL ALL OF THE EQUIPMENT AND THE POWER SUPPLY FOR THE ELECTRIC VEHICLE SUPPLY EQUIPMENT. INCLUDING; CIRCUIT PROTECTION DEVICES AND BRANCH FEEDERS. • PRIOR TO INSTALLATION AND FINAL CONNECTION, VERIFY ELECTRICAL CHARACTERISTICS OF THE DISTRIBUTION SYSTEM AND LOCATION OF THE EVSE. • GROUT AND SEAL ALL CONDUIT PENETRATIONS OF WALLS AND ROOF TO MAINTAIN FIRE RATING AND WATERTIGHT INTEGRITY OF WALLS AND ROOF. GENERAL REQUIREMENTS THE CONTRACTOR WILL BE HELD TO HAVE THOROUGHLY REVIEWED GENERAL CONSTRUCTION DRAWINGS. EXAMINED THE SITE. PREMISES AND SATISFIED HIMSELF AS TO EXISTING CONDITIONS UNDER WHICH HE WILL BE OBLIGED TO OPERATE OR WHICH WILL IN ANY MANNER AFFECT THE WORK UNDER THIS CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART. PROVIDE STANDARD PRODUCTS OF ESTABLISHED MANUFACTURERS REGULARLY ENGAGED IN THE PRODUCTION OF SUCH EQUIPMENT. PROVIDE NEW MATERIAL. APPARATUS AND EQUIPMENT OF THE BEST PRACTICE OF THE ELECTRICAL TRADE AND BY SKILLED CRAFTSMEN. ALL EQUIPMENT SHALL BE LISTED BY UNDERWRITERS LABORATORIES, OR EQUIVALENT NRTL, FOR USE INTENDED. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND THE CONTRACTOR SHALL HARMONIZE HIS WORK SO THAT EACH PIECE OF EQUIPMENT WILL BE INSTALLED SO AS TO FUNCTION PROPERLY. COOPERATE WITH OWNER AND VERIFY ALL EQUIPMENT LOCATIONS. WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL ORDINANCES AND REGULATIONS OF STATE, COUNTY. MUNICIPAL AUTHORITIES. UTILITY COMPANY, N.E.C. AS SHOWN ON CONSTRUCTION DOCUMENTS. SEC CONSTRUCTION DRAWINGS FOR EQUIPMENT LOCATIONS, AND APPLICABLE ELEVATIONS AND DETAILS. ELECTRICAL CONTRACTOR TO VERIFY AND ACKNOWLEDGE ALL CODES AND REGULATIONS PERTAINING TO THIS PROJECT. REFER TO THE NATIONAL ELECTRIC CODE, ARTICLE 625 AND ALL OTHER APPLICABLE SECTIONS OF THE NEC. fiftSMWU CONDUITS SHALL BE SIZED IN ACCORDANCE WITH THE APPROPRIATE TABLE OF NEC. AND SHALL BE OF SUCH SIZE AND SO INSTALLED THAT CONDUCTORS MAY BE DRAWN IN WITHOUT INJURY OR STRAIN. CONDUIT SHALL BE SECURED TO PULL BOXES, SUPPORT BOXES, OR OUTLET SOXES WITH GALVANIZED LOCKNUTS AND BUSHINGS. ALL CONDUITS SHALL BE RUN CONCEALED PRINCIPALLY IN OVERHEAD AND WALL CONSTRUCTION. ALL CONDUIT THAT MUST BE EXPOSED SHALL BE RUN PARALLEL WITH LINES OF THE BUILDING. CHASES AND OPENINGS IN WALLS, PARTITIONS AND aOORS SHALL BE PROVIDED FOR INSTALLATION OF CONDUIT; ALL CONCEALED WORK SHALL BE DONE SO AS TO MINIMIZE CUTTING AND PATCHING. ALL CONDUIT NOT EMBEDDED IN CONCRETE SHALL BE FIRMLY SECURED BY LISTED PIPE CLAMPS, HANGERS, ETC. ELECTRICAL METALLIC TUBING: USED FOR ALL WIRING EXCEPT IN OR UNDER CONCRETE, EARTH, FILL, OR GROUTED BLOCK WALLS. GALVANIZED STEEL CONDUIT: USED FOR ALL WIRING IN OR UNDER CONCRETE, EARTH, FILL AND GROUTED WALLS. IN EARTH OR FILL, COAT WITH POLYETHYLENE TAPE. SPIRAL WRAPPED TO NOT LESS THAN 40MILS. NON-METALUC: LISTED. SCHEDULE 40, PVC MAY BE USED FOR BRANCH FEEDER CIRCUITS IF RUN UNDER CONCRETE FLOOR. PROVIDE BONO WIRE PER NEC. PVC CONDUIT SHALL BE BURIED MINIMUM OF 24 INCHES IF NOT INSTALLED UNDER CONCRETE OR ENCASED IN 3 INCH CONCRETE ENVELOPE. FLEXIBLE METALLIC CONDUIT OR METAL-CLAD CABLE: MAY BE USED FOR SHORT FINAL CONNECTIONS FOR INDOOR EQUIPMENT. PROVIDE INSULATED COPPER BOND WIRE IN ALL FLEXIBLE RACEWAYS AND SIZED PER NEC- 250. LIQUIDT1GHT aEXIBLE MgTALIC CONDUIT: SHALL BE USED OUTDOOR AND IN MOIST LOCATIONS WITH LISTED TERMINATION FITTINGS. •ffifff. ALL CONDUCTORS SHALL BE SOFT DRAWN ANNEALED COPPER HAVING PURE COPPER CONDUCTIVITY OF NOT LESS THAN 98*. UNIFORM IN CROSS SECTION. FREE FROM RAWS, SCALES, AND OTHER IMPERFECTIONS. CONDUCTORS IN CONDUIT: •XHHW-2 OR THWN-2 INSULATION FOR ALL EXTERIOR FEEDERS IN CONDUIT. •THHN-2 INSULATION FOR ALL INDOOR BRANCH CIRCUITS IN CONDUIT. •MINIMUM SIZE WIRE SHALL BE |14 AWG COPPER. •NO WIRE MAY 8E DRAWN INTO CONDUIT UNTIL CONDUIT SYSTEM IS COMPLETE. CONDUCTOR PULLING LUBRICANT SHALL BE USED TO FACILITATE WIRE PULLING. NONMETALLIC-SHEATHED CABLE: NON-METALUC SHEATHED CABLES SIZED PER NEC MAY PROVIDE ALL WIRING CONNECTIONS FOR EQUIPMENT FURNISHED UNDER OTHER SECTIONS OF THE SPECIFICATIONS ALL WIRING SHALL BE TESTED UPON COMPLETION OF WORK, AND ADJUSTMENTS MADE NECESSARY FOR SATISFACTORY OPERATION OF THE SYSTEM. WHERE SUBJECT TO PHYSICAL DAMAGE, CONDUCTORS SHALL BE ADEQUATELY PROTECTED. WHEN THE WRING METHOD IS INSTALLED THROUGH BORED HOLES IN JOISTS. RAFTERS OR WOOD MEMBERS. HOLES SHALL BE BORED SO THAT THE EDGE OF THE HOLE IS NOT LESS THAN 1-1/4* FROM THE NEAREST EDGE OF THE WOOD MEMBER. WHERE THIS DISTANCE CANNOT BE MAINTAINED, THE CABLE SHALL BE PROTECTED FROM PENETRATION BY SCREWS OR NAILS BY A STEEL PLATE, AT LEAST 1/16" THICK, AND OF APPROPRIATE LENGTH AND WIDTH INSTALLED TO COVER THE AREA OF THE WIRING. •GROUNDING CONDUCTORS: ALL GROUND CONDUCTORS SHALL BE SIZED PER NEC 250 PER EACH ADDt I/^AimuArrLlUA HUN. sfflPtateet SiSSTWa IW*C"'A11" REXIKEDA"Vl IUJCn>l TCU 602-343-9006 APPROVALS DATE PROJECT DRAWN CHECKED ENGINEER "ra""° 1694 DOCENA ROAD CARLSBAD, CA 92011 M.G.R. REV. - - SIZE PROJECT 1 - A DO NOT SCALE DRAWINGS SCALE CODE INTENT NO. DWG NO. I I NA | | SHEET - OF - GENERAL NOTES & SPECIFICATIONS (SHEET 2 OF 2) SAFETY SWITCHES SAFETY SWITCHES. SHALL BE HEAVY DUTY TYPE, 240 VOLT MINIMUM WITH THE EXACT NUMBER OF POLES REQUIRED. ALL SAFETY SWITCHES SHALL BE OF THE FUSIBLE TYPE. FUSES SHALL BE SIZED AS RECOMMENDED BY EQUIPMENT MANUFACTURER. THE SWITCH SIZE SHALL BE AS REQUIRED BY THE NEC AND AS INDICATED ON THE DRAWINGS AND SIZED PER HORSEPOWER RATING. WHERE OUTSIDE THE BUILDING, THE SWITCHES SHALL BE RAINTIGHT TYPE NEMA-3R. FUSCg FUSES SHALL BE OF THE TYPE, SIZE AND RATING AS INDICATED ON THE DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ENGINEER ON RECORD FOR RESOLUTION. GROUNDING ELECTRICAL CONTRACTOR SHALL VERIFY PROPER GROUNDING CONNECTIONS, GROUND CONDUCTORS AND INSTALL AS PER THE GROUNDING DETAILS AS INDICATED IN THESE DRAWINGS. ALL EQUIPMENT AND ENCLOSURES, AND THE COMPLETE CONDUIT SYSTEM SHALL BE GROUNDED SECURELY IN ACCORDANCE WITH PERTINENT SECTIONS OF NEC, ARTICLE 250. ALL ELECTRICALLY OPERATED EQUIPMENT SHALL BE BONDED TO THE GROUNDING SYSTEM. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ENGINEER ON RECORD FOR RESOLUTION. BRANCH PANELS BRANCH PANELBOARDS ARE EXISTING AND SHALL BE USED. BREAKER m>E SHALL BE MATCHED WITH THE EXISTING ANO RATED AS SPECIFIED ON THE DRAWINGS. TIE BARS TO FORM TWO-POLE BREAKERS WILL NOT BE ACCEPTED. EACH PANEL SHALL BE PROVIDED WITH A TYPEWRITTEN SHEET INSTALLED ON THE DOOR, WHICH IDENTIFY THE ASSIGNMENT OF EACH BREAKER. FINAL INSPECTION A TESTS FURNISH ALL METERS, CABLE CONNECTIONS ANO APPARATUS NECESSARY FOR TESTING. TEST SYSTEM FOR SHORTS ANO GROUNDS. FAULTY WRING SHALL BE REMOVED AND REPLACED. ANY DEVICE. APPARATUS OR FIXTURE INSTALLED SHOWING SUB-STANDARD PERFORMANCE SHALL BE REMOVED ANO REPLACED AT NO ADDITIONAL COST TO THE OWNER. FIELD NOTES 430 S SECOND AVE.PHCBIOC. AZ 45003 TCL! 602-345-90W APPROVALS DRAWN CHECKED ENGINEER M.G.R. REV. PROJECT f - DO NOT SCALE DRAWINGS PROJECT MAKE:REX IKEDA PROJECT ADDRESS:1694 DOCENA ROAD CARLSBAD, CA 92011 SIZE A CODE INTENT NO.DWG NO. SCALE NA | SHEET - OF IKEDA/SDR-0095 RESIDENTIAL LOAD CALCULATION PANEL TYPE: SIEMENS MAIN CB AMPS: 200 General Lighting and receptacle loads NEC 2008- 220.83 (A)(1)I Square ft PVA/Sqft f Outside dimensions of home (exclude garage) 2700 3 Small appliance and laundry load NEC 2008- 220.83 (A}(2) Small appliance Laundry Special Appliance Loads NEC2008-220.83(AM3) Dishwasher Disposal Microwave Refrigerator Trash Compactor Clothes Washer Force Air Unit A/C Window Unit A/CUntt Cooktop/ Range Clothes Dryer ( electric ) Water Heater Heated Spa Heat Pump Pool Filter 1/2 hp TOTAL: E 'VA/ckt I • #ckls s| 1500 2 1500 1 Phasel ; Wolts ;'••! t:Amps-i 1 1 120 10 1 120 9.3 1 120 12 1 120 3.75 1 120 0 1 120 4.5 1 120 6.25 1 120 0 1 240 24 1 240 24 1 240 0 1 240 0 1 240 0 1 240 0 1 240 0 r VA | 8100 VA" j 3000 1500 VA NOTES: 1200 1116 1440 450 0 540 750 0 5760 5760 0 0 0 0 0 2961 S Applying Demand Load First VA at Indicated % Second VA at Indicated % Electric Vehicle Equipment TOTAL LOADS I •i'fAvA'M^I^^W^l 8000 100 21616 40 7680 100 r VA : :| 8000 8646.4 .7680. DIAL DOWN TO 20A ~24326.4] Applying Demand Load TOTAL SERVICE ENTRANCE LOAD | .i-vv'v W \ 'WW'?&'\ . . VA | 240 | 101.36 |24326.4 1