HomeMy WebLinkAbout1694 DOCENA RD; ; CB111056; Permit05-19-2011
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Cogeneration Permit Permit No:CBl 11056
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
Applicant:
1694DOCENARDCBAD
COGEN Sub Type: EVG
2159103,100 . Lot#: 0 Status:
$0.00 Construction Type: NEW Applied:
Reference #: Entered By:
IKEDA RES: INSTALL 40 AMP CIRC Plan Approved:
& NEMA 6-50 RECEP FOR ELECTRICAL VEH CHARGER- NO Issued:
Inspect Area:
Plan Check#:
Owner:
ISSUED
05/19/2011
JANEAN
05/19/2011
05/19/2011
SUNWEST ELECTRIC INC
3064EMIRALOMAAV 92806
714630-8700
IKEDA 1998 FAMILY REVOCABLE TRUST 11-06-98
1694DOCENARD
CARLSBAD CA 92011
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Green Bldg Stands (SB1473) Fee
Total Fees: $22.00 Total
$0.00
$0.00
$0.00
$0.00
$0.00
$1.00
$1.00
Payments To Date:
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Additional Fees
TOTAL PERMIT FEES
$22.00 Balance Due:
$0.00
$20.00
$0.00
$0.00
$22.00
$0.00
Inspecto
FINALAPRROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protSSt imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
,<&
<4[ ,-* Building Permit: A
<S^5' 1635 Faraday Ave., Carlsb
\S CITY OF 760-602-2717/271?
k^ADI CRAH Fax760-602-8£
V^ AK LO DAL/ www.carlsbadca.!
J°BADDRESS 1694DOCENAROAD
CT/PRQJECTfl LOTfl PHASED tt OF UNFTS tt BEDROOMS
.. .. Plan Check No.(LfoUV<O^ppucotion T'-'^-n
ad, CA 92008 Est. Value
I /O71O'4'^ Plan Ck. Deposit
!°v Date ^ j \c\\ \{ SWPPP
surrE#/sPACE*/uNmt APN
# BATHROOMS TEKAjNT BUSINESS NAME CONSTR, TYPE
DESCRIPTION OFWORK: Include Square Feet of Affected Area(s)
Install 40A circuit and NEMA 6-50 receptacle for Electrical Vehicle Equipment
EXISTING USE PROPOSED USE GARAGE (SF)
CONTACT NAME (If Different Fern Applicant)
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
PROPERT¥OWNERNAME REXIKEDA
ADDRESS
1694 DOCENA ROAD
CITY STATE ZIP
Carlsbad CA 92011
PHONE FAX
760-929-0559
EMAIL
A8CH/DESI6NERNA.ME4ADORESS STATEU&»
-
OCC. GROUP
PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRESPRINKLERS
YESQ» NCJ | YESnNoQ YES| |HO| |
APPLICANT NAME „,Shaun Eastman
ADDRESS
3064 E. Miraloma Ave.
CITY STATE ZIP
Anaheim CA 92806
PHONE FAX
714-678-0083 714-630-8740
EMAIL
seastman@sunwestelect.com
CONTRACTOR BUS. NAME Sunwest Electric, Inc.
ADDRESS 3064 E. Miraloma Ave,
CITY STATE ZIP
Anaheim CA 92806
PHONE FAX
714-60-8700 714-630-8740
EMAIL
seastman@sunwestelect.com
STATE UC.# CLASS CITY BUS. UC.#
511697 CIO 1216494
civil penalty of not more than five hundred dollars {$500}).
Workers' Compensation Declaration: I hereby affim under penalty tf perjury one of the burning dec/aralrare:
LJI have and will maintain a certificate of consent to sell-Insure for workers' compensation as provided by £
l/J I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. My workers' compensation Insurance carrier and policy
number are: Insurance Co oMmpuhikhni«ic«coi|. Policy No. MCIMIUIOW Expiration Date """'"
Thfe section need nol be completed if the permit Is for one hundred dollars ($100) or less.
I I Certificate of Exemption:! certify that in the performance of the work for which IMs permit is Issued, I shall Arfemploy any person in any manner so as to become subject to the Workers' Compensator! Laws of
California. WARNING: Failure to secure workers' compensation coverage is untffivMj*«t$MlsurjJ«t In employer to criminal penalties and chril fines up to one hundred thousand dollars {&100.000), In
addition to Die cost of compenjatkmrdarfHjjes as'ya^did for In Sadlp^ 3706 oj|JiaUbjLfj3jggraAid_ajlornay's fees.
ff< fyiMTRjurrnB BIBMTIIIH: ==^"J^^ *JZ=. -^^ ^*^\~~~~ -^ [7}AGENT DATE
r •».
/ftereoyaffiraiftsl/amommpffrom Contractor's UcensoLw (a Iho Mowing reason:
| [ 1, as ov.ner of the properly or my employees with wages as their cole compensation, will do Die work and the sbucruie is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
sale. If, however, tha bulding or Improvement fe sold within one year of completion, the owner-bu3der will have the burden of proving that lie did not built) or improve for Die purpose of sale).
[/I I, as owier of the properly, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business end Professions Code; The Contractor's License Law does not apply to an owner of
property who builds or Improves Diereon, and contracts lor such projects with cont/actor(s) licensed pursuant to the Contractor's License Uw).
| | I am exempt under Secrjon Business and Professions Code for IMs reason:
1.1 personally plan to provide 8ie major labor and maten'ats forconslrucfon of rjie proposed property hiprovement I lYes I JNo
2.1 (have / have not) signed an application lor a building permit for the proposed work.
3.1 have contracted with (he following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
4.1 plan to provide portions of the work, but I have hired the fotolng person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number):
S. I will provide some of the v«rk. but I have contacted (hired) the following persons to provide the work indicated {taclude name / address / phone / type of work):
^PROPERTY OWNER SIGNATURE 0AGENT DATE
Is the applicant or future building occupant required tosubmil a businessman, scutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 <x 25534 of the
Prestey-TannefHazardousSubstanwAccountAct? QYes I IMP
Is the applicant or future building occupant retired to obtain a psrma from 8ie a'r pollution control district or alrijyality management district? LZJYes I I No
Isttiefac%lol)ecoristructedwilhln1.000feetof8ieouterboundaiy<ifaschoolsrle? LJYes LJtto
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING TH E REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there 1$ a construction lending agency for the performance of (he work this permit Is Issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
I hereby authorize representaSve of the Oty of Carlsbad to enterupon the above rnen&ned properly for tepscSonpunposes. I ALSO AGREE TO SAVE JNDEIWff
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERIAT.
OSHA: An OSHA permit is required for excavations over SO deep and demoffion or construction of structures over3 stories hheighl
EXPIRATION: Every permit Issued by the Building Official under the provisions of this Code sb4JM|ej)£JirJitajion and racome nu5 and void if the building or work authorized by such permit is not commenced wShin
180 days from the date of such pemi^ or if the buMng or work author^ by suehjejT^^
^APPLICANT'S SIGNATURE ja^^S^^^SSS3—~"~~~" _.--—-—' ~" -/X~~^^ rjATE
City of Carlsbad Bldg Inspection Request
For: 06/08/2011
Permit* CB111056
Title: IKEDA RES: INSTALL 40 AMP CIRC
Inspector Assignment:
Description. & NEMA 6-50 RECEP FOR ELECTRICAL VEH CHARGER-
NO SERVICE PANEL UPGRADE
Type:COGEN Sub Type: EVG
Job Address: 1694 DOCENA RD
Suite: Lot: 0
Location:
OWNER IKEDA 1998 FAMILY REVOCABLE TRUST 11-06-98
Owner: IKEDA 1998 FAMILY REVOCABLE TRUST 11-06-98
Remarks:
Phone: 7143188594
Inspectoff1
Total Time:
CD Description
34 Rough Electric
39 Final Electrical
Requested By: NICK
Entered By: CHRISTINE
Act Comments
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
Inspection History
Date Description Act Insp Comments
m° r-o< rn£" CT•as m5Q Z
oa
-o
3>
• •>•'.'-4%, ;l^>* •;:•%.&:
M?&$&
•^tm
GENERAL NOTES & SPECIFICATIONS (SHEET 1 OF 2)
WORK SPFptFIED HEREIN
WORK UNDER THIS SPECIFICATION INCLUDES FURNISHING ALL MATERIAL.
LABOR. EQUIPMENT. ETC., AND FINAL CONNECTION TO EQUIPMENT IN ORDER
TO PROVIDE THE OWNER WITH A COMPLETE AND PROPERLY FUNCTIONAL
ELECTRIC VEHICLE SUPPLY EQUIPMENT. IN GENERAL, THE WORK SHALL
CONSIST OF BUT NOT BE LIMITED TO THE FOLLOWING:
• FURNISH AND INSTALL ALL OF THE EQUIPMENT AND THE POWER SUPPLY
FOR THE ELECTRIC VEHICLE SUPPLY EQUIPMENT. INCLUDING; CIRCUIT
PROTECTION DEVICES AND BRANCH FEEDERS.
• PRIOR TO INSTALLATION AND FINAL CONNECTION, VERIFY ELECTRICAL
CHARACTERISTICS OF THE DISTRIBUTION SYSTEM AND LOCATION OF THE
EVSE.
• GROUT AND SEAL ALL CONDUIT PENETRATIONS OF WALLS AND ROOF TO
MAINTAIN FIRE RATING AND WATERTIGHT INTEGRITY OF WALLS AND ROOF.
GENERAL REQUIREMENTS
THE CONTRACTOR WILL BE HELD TO HAVE THOROUGHLY REVIEWED GENERAL
CONSTRUCTION DRAWINGS. EXAMINED THE SITE. PREMISES AND SATISFIED
HIMSELF AS TO EXISTING CONDITIONS UNDER WHICH HE WILL BE OBLIGED TO
OPERATE OR WHICH WILL IN ANY MANNER AFFECT THE WORK UNDER THIS
CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN BEHALF OF THE
CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART. PROVIDE
STANDARD PRODUCTS OF ESTABLISHED MANUFACTURERS REGULARLY
ENGAGED IN THE PRODUCTION OF SUCH EQUIPMENT. PROVIDE NEW MATERIAL.
APPARATUS AND EQUIPMENT OF THE BEST PRACTICE OF THE ELECTRICAL
TRADE AND BY SKILLED CRAFTSMEN. ALL EQUIPMENT SHALL BE LISTED BY
UNDERWRITERS LABORATORIES, OR EQUIVALENT NRTL, FOR USE INTENDED.
THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND THE CONTRACTOR SHALL
HARMONIZE HIS WORK SO THAT EACH PIECE OF EQUIPMENT WILL BE
INSTALLED SO AS TO FUNCTION PROPERLY. COOPERATE WITH OWNER AND
VERIFY ALL EQUIPMENT LOCATIONS. WORK SHALL BE PERFORMED IN
ACCORDANCE WITH ALL ORDINANCES AND REGULATIONS OF STATE, COUNTY.
MUNICIPAL AUTHORITIES. UTILITY COMPANY, N.E.C. AS SHOWN ON
CONSTRUCTION DOCUMENTS.
SEC CONSTRUCTION DRAWINGS FOR EQUIPMENT LOCATIONS, AND APPLICABLE
ELEVATIONS AND DETAILS. ELECTRICAL CONTRACTOR TO VERIFY AND
ACKNOWLEDGE ALL CODES AND REGULATIONS PERTAINING TO THIS PROJECT.
REFER TO THE NATIONAL ELECTRIC CODE, ARTICLE 625 AND ALL OTHER
APPLICABLE SECTIONS OF THE NEC.
fiftSMWU
CONDUITS SHALL BE SIZED IN ACCORDANCE WITH THE APPROPRIATE TABLE
OF NEC. AND SHALL BE OF SUCH SIZE AND SO INSTALLED THAT
CONDUCTORS MAY BE DRAWN IN WITHOUT INJURY OR STRAIN. CONDUIT
SHALL BE SECURED TO PULL BOXES, SUPPORT BOXES, OR OUTLET SOXES
WITH GALVANIZED LOCKNUTS AND BUSHINGS. ALL CONDUITS SHALL BE RUN
CONCEALED PRINCIPALLY IN OVERHEAD AND WALL CONSTRUCTION.
ALL CONDUIT THAT MUST BE EXPOSED SHALL BE RUN PARALLEL WITH LINES
OF THE BUILDING. CHASES AND OPENINGS IN WALLS, PARTITIONS AND
aOORS SHALL BE PROVIDED FOR INSTALLATION OF CONDUIT; ALL
CONCEALED WORK SHALL BE DONE SO AS TO MINIMIZE CUTTING AND
PATCHING.
ALL CONDUIT NOT EMBEDDED IN CONCRETE SHALL BE FIRMLY SECURED BY
LISTED PIPE CLAMPS, HANGERS, ETC.
ELECTRICAL METALLIC TUBING: USED FOR ALL WIRING EXCEPT IN OR UNDER
CONCRETE, EARTH, FILL, OR GROUTED BLOCK WALLS.
GALVANIZED STEEL CONDUIT: USED FOR ALL WIRING IN OR UNDER
CONCRETE, EARTH, FILL AND GROUTED WALLS. IN EARTH OR FILL, COAT WITH
POLYETHYLENE TAPE. SPIRAL WRAPPED TO NOT LESS THAN 40MILS.
NON-METALUC: LISTED. SCHEDULE 40, PVC MAY BE USED FOR BRANCH
FEEDER CIRCUITS IF RUN UNDER CONCRETE FLOOR. PROVIDE BONO WIRE PER
NEC. PVC CONDUIT SHALL BE BURIED MINIMUM OF 24 INCHES IF NOT
INSTALLED UNDER CONCRETE OR ENCASED IN 3 INCH CONCRETE ENVELOPE.
FLEXIBLE METALLIC CONDUIT OR METAL-CLAD CABLE: MAY BE USED FOR
SHORT FINAL CONNECTIONS FOR INDOOR EQUIPMENT. PROVIDE INSULATED
COPPER BOND WIRE IN ALL FLEXIBLE RACEWAYS AND SIZED PER NEC- 250.
LIQUIDT1GHT aEXIBLE MgTALIC CONDUIT: SHALL BE USED OUTDOOR AND IN
MOIST LOCATIONS WITH LISTED TERMINATION FITTINGS.
•ffifff.
ALL CONDUCTORS SHALL BE SOFT DRAWN ANNEALED COPPER HAVING
PURE COPPER CONDUCTIVITY OF NOT LESS THAN 98*. UNIFORM IN
CROSS SECTION.
FREE FROM RAWS, SCALES, AND OTHER IMPERFECTIONS.
CONDUCTORS IN CONDUIT:
•XHHW-2 OR THWN-2 INSULATION FOR ALL EXTERIOR FEEDERS IN
CONDUIT.
•THHN-2 INSULATION FOR ALL INDOOR BRANCH CIRCUITS IN CONDUIT.
•MINIMUM SIZE WIRE SHALL BE |14 AWG COPPER.
•NO WIRE MAY 8E DRAWN INTO CONDUIT UNTIL CONDUIT SYSTEM IS
COMPLETE. CONDUCTOR PULLING LUBRICANT SHALL BE USED TO
FACILITATE WIRE PULLING.
NONMETALLIC-SHEATHED CABLE:
NON-METALUC SHEATHED CABLES SIZED PER NEC MAY PROVIDE ALL
WIRING CONNECTIONS FOR EQUIPMENT FURNISHED UNDER OTHER
SECTIONS OF THE SPECIFICATIONS
ALL WIRING SHALL BE TESTED UPON COMPLETION OF WORK, AND
ADJUSTMENTS MADE NECESSARY FOR SATISFACTORY OPERATION OF THE
SYSTEM.
WHERE SUBJECT TO PHYSICAL DAMAGE, CONDUCTORS SHALL BE
ADEQUATELY PROTECTED. WHEN THE WRING METHOD IS INSTALLED
THROUGH BORED HOLES
IN JOISTS. RAFTERS OR WOOD MEMBERS. HOLES SHALL BE BORED SO
THAT THE EDGE OF THE HOLE IS NOT LESS THAN 1-1/4* FROM THE
NEAREST EDGE OF THE WOOD MEMBER. WHERE THIS DISTANCE CANNOT
BE MAINTAINED, THE CABLE SHALL BE PROTECTED FROM PENETRATION
BY SCREWS OR NAILS BY A STEEL PLATE, AT LEAST 1/16" THICK, AND
OF APPROPRIATE LENGTH AND WIDTH INSTALLED TO COVER THE AREA OF
THE WIRING.
•GROUNDING CONDUCTORS:
ALL GROUND CONDUCTORS SHALL BE SIZED PER NEC 250 PER EACH
ADDt I/^AimuArrLlUA HUN.
sfflPtateet SiSSTWa IW*C"'A11" REXIKEDA"Vl IUJCn>l TCU 602-343-9006
APPROVALS DATE PROJECT
DRAWN
CHECKED
ENGINEER
"ra""° 1694 DOCENA ROAD
CARLSBAD, CA 92011
M.G.R.
REV. - - SIZE
PROJECT 1 - A
DO NOT SCALE DRAWINGS SCALE
CODE INTENT NO. DWG NO. I
I
NA | | SHEET - OF -
GENERAL NOTES & SPECIFICATIONS (SHEET 2 OF 2)
SAFETY SWITCHES
SAFETY SWITCHES. SHALL BE HEAVY DUTY TYPE, 240 VOLT MINIMUM
WITH THE EXACT NUMBER OF POLES REQUIRED. ALL SAFETY SWITCHES
SHALL BE OF THE FUSIBLE TYPE. FUSES SHALL BE SIZED AS
RECOMMENDED BY EQUIPMENT MANUFACTURER. THE SWITCH SIZE SHALL
BE AS REQUIRED BY THE NEC AND AS INDICATED ON THE DRAWINGS
AND SIZED PER HORSEPOWER RATING. WHERE OUTSIDE THE BUILDING,
THE SWITCHES SHALL BE RAINTIGHT TYPE NEMA-3R.
FUSCg
FUSES SHALL BE OF THE TYPE, SIZE AND RATING AS INDICATED ON
THE DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ENGINEER ON RECORD FOR RESOLUTION.
GROUNDING
ELECTRICAL CONTRACTOR SHALL VERIFY PROPER GROUNDING
CONNECTIONS, GROUND CONDUCTORS AND INSTALL AS PER THE
GROUNDING DETAILS AS INDICATED IN THESE DRAWINGS. ALL EQUIPMENT
AND ENCLOSURES, AND THE COMPLETE CONDUIT SYSTEM SHALL BE
GROUNDED SECURELY IN ACCORDANCE WITH PERTINENT SECTIONS OF
NEC, ARTICLE 250. ALL ELECTRICALLY OPERATED EQUIPMENT SHALL BE
BONDED TO THE GROUNDING SYSTEM. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ENGINEER ON RECORD FOR RESOLUTION.
BRANCH PANELS
BRANCH PANELBOARDS ARE EXISTING AND SHALL BE USED. BREAKER
m>E SHALL BE MATCHED WITH THE EXISTING ANO RATED AS SPECIFIED
ON THE DRAWINGS. TIE BARS TO FORM TWO-POLE BREAKERS WILL NOT
BE ACCEPTED. EACH PANEL SHALL BE PROVIDED WITH A TYPEWRITTEN
SHEET INSTALLED ON THE DOOR, WHICH IDENTIFY THE ASSIGNMENT OF
EACH BREAKER.
FINAL INSPECTION A TESTS
FURNISH ALL METERS, CABLE CONNECTIONS ANO APPARATUS
NECESSARY FOR TESTING. TEST SYSTEM FOR SHORTS ANO GROUNDS.
FAULTY WRING SHALL BE REMOVED AND REPLACED. ANY DEVICE.
APPARATUS OR FIXTURE INSTALLED SHOWING SUB-STANDARD
PERFORMANCE SHALL BE REMOVED ANO REPLACED AT NO ADDITIONAL
COST TO THE OWNER.
FIELD NOTES
430 S SECOND AVE.PHCBIOC. AZ 45003
TCL! 602-345-90W
APPROVALS
DRAWN
CHECKED
ENGINEER
M.G.R.
REV.
PROJECT f -
DO NOT SCALE DRAWINGS
PROJECT MAKE:REX IKEDA
PROJECT ADDRESS:1694 DOCENA ROAD
CARLSBAD, CA 92011
SIZE
A
CODE INTENT NO.DWG NO.
SCALE NA | SHEET - OF
IKEDA/SDR-0095
RESIDENTIAL LOAD CALCULATION
PANEL TYPE: SIEMENS
MAIN CB AMPS: 200
General Lighting and receptacle loads
NEC 2008- 220.83 (A)(1)I Square ft PVA/Sqft f
Outside dimensions of home (exclude garage) 2700 3
Small appliance and laundry load
NEC 2008- 220.83 (A}(2)
Small appliance
Laundry
Special Appliance Loads
NEC2008-220.83(AM3)
Dishwasher
Disposal
Microwave
Refrigerator
Trash Compactor
Clothes Washer
Force Air Unit
A/C Window Unit
A/CUntt
Cooktop/ Range
Clothes Dryer ( electric )
Water Heater
Heated Spa
Heat Pump
Pool Filter 1/2 hp
TOTAL:
E 'VA/ckt I • #ckls s|
1500 2
1500 1
Phasel ; Wolts ;'••! t:Amps-i 1
1 120 10
1 120 9.3
1 120 12
1 120 3.75
1 120 0
1 120 4.5
1 120 6.25
1 120 0
1 240 24
1 240 24
1 240 0
1 240 0
1 240 0
1 240 0
1 240 0
r
VA |
8100
VA" j
3000
1500
VA NOTES:
1200
1116
1440
450
0
540
750
0
5760
5760
0
0
0
0
0
2961 S
Applying Demand Load
First VA at Indicated %
Second VA at Indicated %
Electric Vehicle Equipment
TOTAL LOADS
I •i'fAvA'M^I^^W^l
8000 100
21616 40
7680 100
r
VA : :|
8000
8646.4
.7680. DIAL DOWN TO 20A
~24326.4]
Applying Demand Load
TOTAL SERVICE ENTRANCE LOAD
| .i-vv'v W \ 'WW'?&'\ . . VA |
240 | 101.36 |24326.4 1