HomeMy WebLinkAbout1706 FAIRLEAD AVE; ; CB120235; Permit04-30-2012
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No: CB120235
Building Inspection Request Line (760) 602-2725
1706 FAIRLEAD AV CBAD
RESDNTL Sub Type: CONDO Status: ISSUED
2466202645 Lot#: 45 Applied: 10/19/2011
$175,963.00 Constuction Type: 5B Entered By: RMA
Reference tfTCl 04UUT0 1 Plan Approved: 04/30/2012
1 Stmcture Type: MF5+ issued: 04/30/2012
3 , Bathrooms: ZSL-— —, Inspect Area:
Grig PC/gC^I-l0047 Plan Check #: PC110047
VTTALIA CONDG-MGDEL UNH" 45
PLAN 2,1500 SF, 431 SF GAR, 256 SF DECK, BUILDING # 6,
(BUILDING TYPE= A)
Applicant
SHEA HGMES
ATTN: SARAH BECKMAN
STE 200
9990 MESA RIM RD 92121
858 526-6554
Gwner:
Building Permit $993.54 Meter Size
Add'l Building Permit Fee $0.(K)Add'l Reel. Water Con. Fee $0.00
Plan Check $695.48 Meter Fee $0.00
Add'l Plan Check Fee $0.00 SDCWA Fee $0.00
Plan Check Discount $0.00 CFD Payoff Fee $2,545.00
Strong Motion Fee $17.60 PFF (3105540)$3,202.53
Park in Lieu Fee $0.00 PFF (4305540)$0.00
Park Fee $0.00 License Tax (3104193)$0.00
LFM Fee $0.00 License Tax (4304193)$0.00
Bridge Fee $0.00 Traffic Impact Fee (3105541)$1,872.00
Gther Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00
BTD #2 Fee $0.00 Sidewalk Fee $0.00
BTD#3Fee $0.00 PLUMBING TGTAL $164.00
Renewal Fee $0.00 ELECTRICAL TGTAL $55.00
Add'l Renewal Fee $0.00 MECHANICAL TGTAL $99.00
Gther Building Fee $0.00 Housing Impact Fee $0.00
HMP Fee $0.00 Housing InLleu Fee $0.00
Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00
Meter Size Master Drainage Fee $0.00
Add'l Pot Water Con. Fee $0.00 Sewer Fee $2,743.00
Reel. Water Con. Fee $0.00 Additional Fees $0.00
Green BIdg Stands (SB1473) Fee $4.00 Fire Sprinkler Fees $0.00
Green BIdg Stands Plan Chk Fee $0.00
TGTAL PERMIT FEES $12,391.15
Total Fees: $12,391.15 Total Payments to Date:$12,391.15 Balance Due:$0.00
Inspector:
FINAL APPROVAL
Date: /( /Y Clearance:
NOTICE; Please take NOTICE ttwt approval o( your project Includes the Imposttlon' o( fees, dedteatkxis, reservations, or other exactions hereafter cdectively
referred to as fees/exactions." You have 90 days from the (tete this permit was Issued to protest Imposition of these fees/exactions. If you protest them, you must
fo»ow the protest procedures set forth In Qovemmsnt Code Section 06020(a), and fie the protest and any other required Information with the City Manager for
processing In accordance with CartsJrad Municipal Code Section 3.32.030. Failure to Imeiy foilow that procedure wHI bar any subsequent legal action to attack,
review, set aside, void, or annul their Impositioa
You are hereby FURTHER NOTinED that yow right to protest the ^jedfled fees/exactions DOES NOT APPLY to vrater and sewer connection fees and capacity
ctanges, nor planning, zoning, gracflng or other similar application processing or senrice fees In connection with this prefect NOR DOES FT APPLY to any
feea/exactlons of which vou have wevlousiv been given a NOTICE similar to this, or as to which the statute of hnltations has oreviousiv otherwise expired.
Inspection List
Permit#; CB120235 Type: RESDNTL CONDO
Date
10/30/2014
10/30/2014
02/20/2013
11/01/2012
10/12/2012
10/11/2012
10/05/2012
10/03/2012
09/24/2012
09/21/2012
09/20/2012
08/30/2012
08/30/2012
08/20/2012
08/09/2012
08/07/2012
08/06/2012
08/06/2012
07/20/2012
07/09/2012
07/09/2012
06/27/2012
06/20/2012
06/18/2012
05/24/2012
05/18/2012
05/17/2012
05/17/2012
Inspection Item
89 Final Combo
Final Combo
Compliance Investigation
Final Combo
Compliance investigation
308 Final
308 Final
39 Final Electrical
23 Gas/Test/Repairs
23 Gas/Test/Repairs
23 Gas/Test/Repairs
301 Overtiead Hydro
303 Overhead Visual
18 Exterior Lath/Drywaii
16 insulation
84 Rough Combo
84 Rough Combo
89 Final Combo
13 Shear Paneis/HD's
13 Shear Paneis/HD's
18 Exterior Lath/Drywail
16 insulation
17 interior Lath/Drywaii
13 Shear Paneis/HD's
11 Ftg/Foundation/Fiers
21 Underground/Under Floor
21 Underground/Under Floor
22 Sewer/Water Service
Inspertor
PB
PB
PB
PB
gr
GR
PB
PB
PB
PB
gr
gr
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
AP
Ri
AP
AP
fiP
AP
AP
AP
AP
NS
NR
AP
AP
AP
AP
AP
NR
WC
AP
PA
WC
PA
PA
PA
AP
AP
NR
NR
VITALIA CONDO-MODEL UNIT 45
PLAN 2,1500 SF, 431 SF GAR, 256 SF DE
Comments
COF
MODEL USE ONLY
Friday, October 31, 2014 Page 1 of 1
^ CITY OF
CARLSBAD
Building Department
INSPECTION RECORD
INSPECTION RECORD CARD WITH APPROVED
PLANS MUST BE KEPT ON THE JOB
PRIOR TO 4l0a-P.M. FOR NEXT
LJork day inspection
CB120235 FAIRLEADAV
VITALIA CONCKD-'moDElLnIT 45
PLAN 2, 1500 SP^4a4-SF 3AR, 256 SF DECK, BUI^NG
6. (BUILDING TYPE= A) '
RESDNTL CONDO
Lot#; 45 SHEA HOMES
wi-wrvj Dunujdr
FOR BUILDING INSPECTION
CALL: 760-602-2725
RECORD COPY
APPROVED TO COVER DATE:
Type of Inspection Date inspector Notes
BUILDING
FOUNDATION ILl.
REINFORCED STEEL
MASONRY
□ GROUT □ WALL DRAINS
TILT PANELS
POUR STRIPS
COLUMN FOOTINGS
SUBFRAME □ FLOOR □ CEIUNG
ROOF SHEATHING
EXT. SHEAR PANELS
FRAME
INSULATION
l-Zo-rLY-T- ri
l-l-n-EXTERIOR LATH
INTERIOR LATH & DRYWALL
CJ«
PLUMBING
n SEWER AND BL/CO □ PL/CO
UNDERGROUND □ WASTE □ WATER
TOP OUT □ WASTE □ WATER sk-TUB AND SHOWER PAN
^GAS TEST □ GAS PIPING
□ WATER HEATER □ SOLAR WATER 'm
FINAL
ELECTRICAL
□ ELECTRIC UNDERGROUND □ UFER
ROUGH ELECTRIC WALLS
ROUGH ELECTRIC CEILING
□ ELECTRIC SERVICE □ TEMPORARY
□ BONDING □ POOL
PHOTO VOLTAIC
FINAL
MECHANICAL
UNDERGROUND DUCTS & PIPING
□ DUCT & PLEM.□ REP. PIPING
rw-^wwisr-*r»-*anar-
APPROVED TO COWR DATE:'vm'n-z-
T^pe of Inspection Date Inspector Notes
BUILDING m-M /s s/^sAnn^
Olll/ --f ,4i_
4
FOUNDATION
2 ^'^ £^*JAIL - ^REINFORCED STEEL
MASONRY
n GROUT □ WALL DRAINS
TILT PANELS
POUR STRIPS
COLUMN FOOTINGS
SUBFRAME □ FLOOR □ CEIUNG
ROOF SHEATHING
EXT. SHEAR PANELS
FRAME ■1-
INSULATION
EXTERIOR LATH
INTERIOR LATH & DRYWALL
C3^PLUMBING
□ SEWER AND BL/CO □ PL/CO #■UNDERGROUND □ WASTE □ WATER
TOP OUT □ WASTE □ WATER
TUB AND SHOWER PAN
^GASTEST □ GAS P
□ WATER HEATER
IPING
□ SOLAR WATER
FINAL
ELECTRICAL
□ ELECTRIC UNDERGROUND □ UFER
ROUGH ELECTRIC WALLS
ROUGH ELECTRIC CEIUNG 1
□ ELECTRIC SERVICE □ TEMPORARY
□ BONDING □ POOL
PHOTO VOLTAIC
FINAL
MECHANICAL
UNDERGROUND DUCTS & PIPING
□ DUCT&PLEM. □ REF. PIPING
HEAT - AIR COND. SYSTEMS
.NTILATING SYSTEMS
HNAL
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVED
FINAL Sign When Appropriate
Building Dcpt (Inspxxtlons)(760) 602-2725 %Fire Department (760) 602-W60
Planning Department (760) 602-4602
Engineering Dept (Inspections) (760)438-3891
Building Inspectors (7am-4pm) (760) 602-2700
CMWD (760) 438-2722 Ext 7151
pEV 8/2009
1635 Faraday Ave. ♦ Carlsbad, CA 92008 ♦ 760^02-2700 ♦ www.carlsbadca.gov
SEE BACK FOR SPECIAL NOTES
^ CITY OF
CARLSBAD
CIRCUIT CARD
Br36
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
this card must B£ filled OtJT AND AVA1LABLH-A.'f 'triH 8HRVIU8
Address: fohnieU 4rt.
UiPMarri WK 1 na JS-ouun
Permit Number
Owner. S/<*- fiswctyt Phone;AreainSq.iR.
m TQ a WIFtE
Contractor Cpv^Phone:
A , ^ \if
n PANEL;.
LOCATION CKT BKR
SIZE
w
SIZE
RE
TYPE
MISC REC REG LTQ MISC
w
SEE
IRE
■TYPE .
BKR
SEE CKT LOCATION
1 iu n-17.cu
.
2
P >4 0 3 ca.1 (:o 1C>4
r • rT. V
-5 i«r (Lj Cu,1 1-7.Co 6
7
-i—i—
l< 1 Cc )1 X'K iq Co ir 8 Swv(\>i "?p^) Vv. _
0 /\\c^9 .1"^II 1 (i l s /■,/wU q;10 rt/Afs4e^
11 lo (JJ (w \o.12 WiVN
A- /( 0 13 UO IC7 Cx)1 If c IS (CJ 14 f Aaa.
16 Uu 1 6 7.M (i j (S 16
17 20 CO r./o 'M O)i<18
lortUtA-l l-T
fWvC 19 iS |((:0 7 \20
21
1 22
23 24
26 26
27 28
29 .30
31 32
33
34
36
36
37
38
39 \40
41 •42
main; 100 AMP BRK/FUSE □ MLOBUS: " AMP
Service entrance or feeder cooductors:
A) Size; No..
0) Insulation:.
Service ground/bond:
A) Size: No.
B) Type; □ CU H ALD) Conduit Size:
C) Ciamp location(6):ilyPER□ Water Pipe
□ Ground Rod
□
B)Type: ®CU DaL
250 - 50(c)
250-104'
250 - 52
ISComputed Load See Calculation Wori<sheet on back
Branch circuits required:A) Lighting Olrciiits 220 - 3(b), 4(d)B) Two Small Appliance Circuits 210-11(e)C) Laundry CIrarit 220-16(5)D) Central Heating Equipment 422 -12E) Bathroom 210-52(d) •Remarks: flcv h TV \^'1 ' ^
AMPS
GFCI locations 210 - 8, 880 - 70:
JaBathrDom(8)JS-Garage(6)
<3^0ufdoor8
AFbl Protected CIrc. 210-12J0_Bedroom(s)
jBlKltchen□Hydromassage Tub
□
I certify that all termlnaSons have been torqued In aocajdanoe with manuMure^instructions and that the woric shown on this droult card'represents the full extent ofthe work perfonnedun^r this, fi^nnlt Jsc>-
□ Contractor U _—^glpnsd >1
B-36 Page 1 of 2 Rev. 03/09
SINGLE FAMILY DWEbfi
ELECTRICAL SERVICE LOAD CALCULATION
As an alternative method, the STANDARD METHOD
found In ARTICLE 220 of the Nationai Electric Code, may be used
1. GENERAL UGHTING LOADS ^
Dwelling fSOO sq. ft. x 3 VA = 220-3{a) HSQO VA
Small appliance loads-220-16(a) 1500 VA x 7^ circuits = VA
Laundry load-220-16(b) 1500 VAx___l circuits = lSoC> VA "
General Lighting Total 7 vOO vA
2. COOKING EQUIPMENT LOADS - Nameplate Value
Range VA =
Cooktop VA =
Oven(s)~ %(>oO VA =
VA
VA
VA-ASCO ... .
Cooking Equipment Total__^o££_VA
3. ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum)
Dryer VA =
4. FIXED APPLIANCE LOADS 230-30 (b) (3)
Dishwasher =
Disposal =
Compactor =
Water Heater = '
Hydromassage Bathtub = :
Microwave Oven =
Built-in Vacuum =
=
5. OPTIONAL SUBTOTAL (Add all of the above totals)
Dryer, Total_
I ZOO
eoe>
0DO
VA
VA
VA
VA
VA
VA
VA
VA
Fixed Appliance Total.
*=<00
VA
H'^00 VA
ngoo VA
6. APPLYING DEMAND FACTORS - TABLE 220-30
Rrst 10,000 VAX 100% =
Optional Subtotal (from line 5) { Remaining TSoP VA x 40%=
7. HEATING OR AC LOAD - TABLE 220-30
Larger of the Heating or AC Load =
8. OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7) =
9. MINIMUM SERVICE SIZE = Optional Loads Total a
240 Vdt
10,000 VA
go40 YA
5'76Q VA
/^^60 VA
_ Ampere
(Please put total on front of card under Computed Load)