HomeMy WebLinkAbout1790 FAIRLEAD AVE; ; CB112688; Permit04-30-2012
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No: CB112688
Building Inspection Request Line (760) 602-2725
1790 FAIRLEAD AV CBAD
RESDNTL Sub Type: CONDO
^100203311- Lot#: 11
$117,959.00 Gonstuctlon Type;
Status: ISSUED
Applied: 10/19/2011
Entered By: RMA
1
^5A— ..
Reference #CGT04010A '
Structure Type: MF5+
Bathrooms: 2
Grig PC $r]gG410053~)
UNIT 11
Plan Approved: 04/30/2012
Issued: 04/30/2012
Inspect /\rea:
Plan Check #:
VITALIA FLATS/CONDO n
3RD FLOOR - BUILDING #9- UNIT TYPE B-2- 1004 SF, 427 SF
GARAGE @ REAR OF 1ST FLOOR. 54 SF BALCONY. 25 SF STORAGE
AREA
Applicant:
SHEA HOMES INC
ATTN: SARAH BECKMAN
STE 200
9990 MESA RIM RD -92121
858 526-6554
Owner
Building Permit $766.18 Meter Size
Add'l Building Permit Fee $0.00 Addl Red. Water Con. Fee $0.00
Plan Check $536.33 Meter Fee $0.00
Add'l Plan Check Fee $0.00 SDCWA Fee $0.00
Plan Check Discount $0.00 CFD Payoff Fee $2,545.00
Strong Motion Fee $11.80 PFF (3105540)$2,146.85
Park in Lieu Fee $0.00 PFF (4305540)$0.00
Park Fee $0.00 License Tax (3104193)$0.00
LFM Fee $0.00 License Tax (4304193)$0.00
Bridge Fee $0.00 Traffic Impact Fee (3105541)$1,872.00
Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00
BTD #2 Fee $0.00 Sidewalk Fee $0.00
BTD #3 Fee $0.00 PLUMBING TOTAL $150.00
Renewal Fee $0.00 ELECTRICAL TOTAL $55.00
Addl Renewal Fee .$0.00 MECHANICAL TOTAL $63.00
Other Building Fee $0.00 Housing impact Fee $0.00
HMP Fee $0.00 Housing inLieu Fee $0.00
PoL Water Con. Fee $0.00 Housing Credit Fee $0.00
Meter Size Master Drainage Fee $0.00
Add'l PoL Water Con. Fee $0.00 Sewer Fee $2,743.00
Red. Water Con. Fee n $0.00 Additional Fees $0.00
Green Bidg Stands (SB1473) Fee $4.00 Fire Sprinkler Fees $0.00
Green Bidg Stands Plan Chk Fee $0.00
TOTAL PERMIT FEES $10,893.16
Total Fees: $10,893.16 Total Payments to Date:$10,893.16. Balance Due:$0.00
inspectior:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project Includes the Imposition' of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions.' You have 90 days from the date this permit was Issued to protest Imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth In Government Code Section 66020(a), and file the protest and any other reqiirBd information with the City Manager for
processing In accordance with Cartstiad Municipal Code Section 3.32.030. Falure to timely follow that procedure wU tar any sutaequent legal action to attack,
review, set aside, vokJ, or annuf their Imposition.
You are hereby FURTHER NOTIRED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar appBcatlon processing or service fees In connection with this project. NOR DOES IT APPLY to any
fees/exactions of which VQU have LxevlQUslv been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv otherwise expired.
Inspection List
Permit#: CB112688 Type: RESDNTL CONDO
Da^ Inspection Item
11/30/2012 308 Final
11/30/2012 89 Final Combo
11/29/2012 89 Final Combo
11/29/2012 89 Final Combo
11/27/2012 29 Final Plumbing
10/23/2012 39 Final Electrical
09/28/2012 17 interior Lath/Drywall
09/24/2012 17 Interior LattT/Drywall
09/21/2012 17 Interior Lath/Drywall
09/20/2012 17 Interior Lath/Drywall
09/10/2012 18 Exterior Lath/Drywall
09/05/2012 17 Interior Lath/Drywall
08/31/2012 16 Insulation
08/31/2012 16 Insulation ^ '
08/30/2012 84 Rough Combo
08/29/2012 14 Frame/Steel/Bolting/Weldin
08/29/2012 14 Frame/Steel/Boltlng/Weldin
08/26/2012 301 Overhead Hydro
08/26/2012 303 Overhead Visual
08/02/2012 16 Insulation
08/01/2012 13 Shear Panels/HD's
07/27/2012 22 Sewer/Water Service
07/27/2012 24 Rough/Topout
07/26/2012 13 Shear Panels/HD's
07/18/2012 15 Roof/Reroof
07/11 /2012 13 . Shear Panels/H D's
07/09/2012 11 Ftg/Foundation/Piers
06/29/2012 17 Interior Lath/Drywall
06/12/2012 13 Shear Panels/HD's
05/29/2012 11 Ftg/Foundation/Piers
05/22/2012 21 Underground/Under Floor
05/21/2012 21 Underground/Under Floor
Inspector
gr
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
PB
gr
gr
PB
PB
PB
PB V
PB
PB
PB
PB
PB
PB
MC
PB
PB
Act
AP
AP
NR
Ri
AP
AP
AP
CA
AP
NR
AP
AP
AP
AP
AP
CA
CA
AP
AP
PA
AP
WC
NR
PA
AP
CO
fiP
PA
NR
AP
AP
NR
VITALIA FLATS/CONDO - UNIT 11
3RD FLOOR - BUILDING #9- UNIT TYPE B-
Comments
RECEIVED SOILS, PT/VsJD FORM CERT.
Monday, December 03, 2012 Page 1 of 1
A
^ CITY OF
CARLSBAD
Building Pepartment
INSPECTION RECORD
INSPECTION RECORD CARD WITH APPROVED
PLANS MUST BE i^PT ON THE JOB
/'"ALL PRIOR TO ««e-P.M. FOR NEXT
. ORK PAY INSPECTION
CB112688 1790 FAIRLEAD AV
VITALIA FIATS/CONDO - UNIT 11 ^ ^ ^
3RD FLOOR - BUILDING #9- UNIT TYPE B-2-1004 SF,
427 SF GARAGE @ REAR OF 1ST FLOOR, 54 SF
BALCONY, 25 SF STORAGE AREA
RESDNTL CONDO
Lot#; 11 SHEA HOMES INg
FOR BUILDING INSPECTION
CAU: 760-602-2725
1
recPrd copy
APPROVED TO COVER DATE:
Type Of Inspectiofi ' Date inspector Notes
BUUJMNG
FOUNDATION
I <1^9 ickx fr-Jf tiAo
REINFORCED STEEL
MASONRY SooC it- /^Alii/Mi
□ GROUT □ WALL DRAINS 2^ OA ' S
TILT PANELS
. POUR STRIPS . -
COLUMN FOOTINGS
SUBFRAMEt □ FLOOR □ CEIUNG
ROOF SHEATHING
EXT. SHEAR PANELS - w
FRAME n
INSULATION
EXTERIOR LATH
INTERIOR LATH & DRYWALL rf>
'
PLUMBING
□ SEWER AND Bl/CO □ PI/CO 07 '(
UNDERGROUND □ WASTE □ WATER
TOP OUT: □ WASTE □ WATER
\
C
■1
oiiTUB AND SHOWER PAN
□ GAS TEST □ GAS PIPING
□ WATER HEATER . □ SOLAR WATER \
FINAL
ELECTRICAL '
□ ELECTRIC UNDERGROUND □ UFER.
ROUGH ELECTRIC WALLS A fkROUGH ELECTRIC CEIUNG
□ ELECTRIC SERVICE □ TEMPORARY ,K
□ BONDING □ POOL
PHOTO VOLTAIC
FINAL
MECHANICAL
UNDERGROUND DUCTS & PIPING
□ DUCT&PLEM. DREF. PIPING
HEAT - AIR COND. SYSTEMS rP V^NTILATING SY5TEIVIS
nNAL
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVEDFINAL Sign When Appropriate
BuUtUng Dept (InspecdonsJ (760)602-2725 '
Fire Department (760)602-4660 ,i^-,
Planning Department .(760) 602-4602 '
Engineering Dept (Inspections](760) 438-3891 Wfij^hz.
Building Inspectors (7am-4pm)(760) 602-2700 f **^7' .
f-
CMWD (760) 438-2722 Ext 7151 .
REV 8/2009
1635 Faraday Ave. * Carlsbad, CA 92008 * 760-602-2700 * www.carlsbadca.gov
SEE BACK FOR SPECIAL NOTES
^ CITY OF
CARLSBAD
CIRCUIT CARD
B-36
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
THIS CARP MUST BE FMJD OUT AND AVAEJ^BI;B AT THE aERVICEEOUlFMEm'FOR THE ROUOHINSPBCnCa^
Address: 1*7^0 Av€/.
Osvner
Contractor, 9cmvu/U<i.FAiMy^
Phone;
Phone: ^<7-S79-65«>
PennttNurnben
AnealnSqiPL ; \ 00
. PANEL:AXC VOLTS .0 WIRE
LOCATION ..CKT BKR WIRE .MISC REC REC LTQ IvBSC
WIRE : ,BKR CKT LOCATION
- SIZE •SIZE "TYPE SIZE TYPE SEE
FAU 1 IS w cv Z .1.i-H tu 2 T^ICAro
pAU 3 IS i4 CA>]IM to tS 4
5 io 10 r W 1 1 IM tv 6 ■pisW.
Mc 1 10 cu z tu 1$8 •
OVtP 9 .to I'i-CM \5 e a VH tu IS AfU 10
OVC^^1-r . zo tw e \(r H XJU 15 12
D*>VS«.13 30 10 t-u 1 10 3 5"tu \S AfU 14
PilVQL 15 50 10 Z tv 20ATH"16.ft iv\.
17 .•I \Z CO TjP MS
19 3 iz cv Zo 20
21 Z.a cv 2o 22 |C»^ HZ
23 3 )Z cv ZjP 24 'SotUl
25 -26
27 28
29 .lo
31 32
33 34
35 36
37 38
39 \40
41 42
MAIN! ISl \0b AK
tj.
IP BRK/FUSE □ MLO Cotfiputed Load 03 AMPS
BUS: ITS AMPS»rv(o« enbinc® or (9«d«r oonduotor*:
A) Size: No. LC) Insuiatlon:,Service ground/bond;A) Size: No. \ft>^ O
B)Type: □ CU?3aL
D) Conduit Size:
amp lcicatk)n(s);^UFER
□ Water Pipe
□ Ground Rod
□
B)Type;,®CU Dal
250 - 5D(c)
250-104'
250 - 52
QPa locatloriB 210 - 8, 680 - 7a
BLBathroom{s)
aGarBge(s)
^Outdoors
AFCI Protected Circ. 210-12
(BBedoonXs)
□ Kitchen□Hydrornassage Tub
□
Branch drctdtS'required;A)U^gClrcuto 220 - 3(b), 4{fITB)Two SitbIJ Appliancedrctrffs ' 210-11{e)C) Laundry Cirwit 220 - 16(b)D) Central Heating Equ^jment - 422 —12E) Bathroom 210-52(6) ■
p«n^- 0^^ aimv» .wim -rmi zy
I cerfflythatalltennlnsSonshaVB bean torqued In accxkdancs with manufycturer'aInstructions and that ffte vmrk shown on this drvult cerd'reprBsents the fiM extent of
the work perforwed under thls permA ,gt Owner Ce,lyl h>jl Gafp-□ Contractor /liity irj-tlaskgied ^ --- Date_^!!^—ff' 'A
B-36 Page 1 of 2 Rev. 03/09
SINGLE FAMILY DWELUNG
ELECTRICAL SERVICE LOAD CALCULATION
As an altem§Pve method, ,the, ST^DAf^^, METHOD
found In ARVCLE^20 of the Nationa] Bectric Code, /r?ay be used
GENERAL UGHTING LOADS
Dwelling iOO»f sq. fL x 3. VA = 2204{a)
Small appliance loads - 220-16(a) f600 VA x T-
Laundry load - 220-16(5) 1500 VA x !
circuits =
circuits =
'^OCO
VA
"VA
"VA
COOKING EiQUIPMENT LOADS - Nameplate Value
Range - l_ VA =
Cooklop - VA =
Oven fe) ,^'iOOO VA =
ISOP
General Lighting Total 75'T- VA
VA
VA
VA
3. ELECTRI,C.DRYER1^0-18 (Nameplate, 500D VA rfi'mimum)
Drver VA= ^
4. RXEP:APP*LIANCE LOADS 230-30 (b)(3)
Dishwasher =
Disposal =
Compactor =
Water Heater =
Hydromassage Bathtub =
Microwave Oven =
Built-in Vacuum =FAL) =
5. OPTIONALGUBTOTAL (Add alLof the ahgyet totals)
3000
Cooking Equipment Total VA
Dryer.Total__5555L—.VA
800
800
VA
VA
VA
'VA
VA
VA
VA
.VA
Fixed Appliance Tctel.
IT. 0 0
qpo
VA
ZPfl?, VA
6. APPLYING DEMAND FACTORS - TABLE 220-30Fkst 10,000 VAx 100% =
Optional Subtotal (from line 5) { Remaining VAx 40%=
7. HEATING OR AC LOAD - TABLE 220-30
Larger of the Heating or AC , Load =
8. OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7) =
9. MINIMUM gPfcviGF SI^gE g Optional Loads Total "
240 Volt
10.000 VA
VA
57^0 VA
/9'?Z6 VA
83 .Ampere
(Please huttotal on front of card under Computed Load)