Loading...
HomeMy WebLinkAbout1790 MAGNOLIA AVE; ; CB911048; PermitB U I L D I N G P E R M I T 09/25/91 12:00 Page 1 of 1 Job Address: 1790 MAGNOLIA AV Str: Permit Type: RESIDENTAL ADD/ALT (OVER $10K) Parcel No: 205-230-16-00 Valuation: 49,703 Construction Type: VN Occupancy Group: R3/M Description: 90 SF STORAGE : 443 SF GARAGE Class Code: + 296 SF RAD+ (LEGALIZE SOME EXISTING) Permit No: CB911048 Project No: A91012o6 Development No: Fl: Ste: 4562 09/'25/91 0001 01 02 C-PRHT 545-00 St4f-s~~~ED Applied: 07/17/91 Apr/Issue: 09/25/91 Validated By: KZH Appl/Ownr : JOEL ROGERS 729-0553 2942 HARDING ST STE. E ~~-- CARLSBAD, CA 92008 OWNER MOE, ~EWIS AND JULIE *** Fees Required ~* Fees: Adjustments: Total Fees: Credits .00 202.00 545.00 "A* Fee description Ext fee Data Building Permit Plan Check Strong Motion Fee * BUILDJ:NG TOTAL Enter "Y" for Plumbing Issue ree Each Plumbing Fixtur~ or Each Water Heater and or * PLUMBING TOTAL Enter "Y" for Electric Enter "Y" for Remodel * ELECTRICAL TOTAL ($10 Minimum) Enter 'Y' for Mechanical Issue fee> lnstall Furn/Ducts > Each Install/ eloc Appliance Vent> * MECHANICAL TOTAL 1 1 9.00 4.50 415.00 270.00 5.00 690.00 7.50 Y 2.50 2.50 13.00 5.00 Y 10.00 Y 15.00 15.00 Y 9 .00 4.50 29 .00 l ~ A PROVALI L, l!'it INSP . .t,~_..._~ _DATE# CLEARANCE --------- CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 •--------------------. -···-------~----·-~----- PERMIT APPLICATION City of carlsbad Building Departaent 2075 Las PalES Dr., carlsbad, CA 92009 (619) 438-1161 I. P£ltMI I hPE A -U Commercial U New Building Li I enant Improvement B -□ Industrial □ New Building □ Tenant Improvement C -l(Residential D Apartment □ Condo ~{ngle Family Dwelling ,m Addition/ Alteration □ Duplex □ Demolition □ Relocation □ Mobile Home □ Electrical □ Plumbing □ Mechanical D Pool □ Spa □ Retaining Wall D Solar □ Other 2. PRQJF.Cf INFORMATION FOR OFFICE USE ONLY Address \ t"P !"'\l"C:,'NC>l.lA i"\\Jer'uddmg or Suite No. ZIP CODE ADDRESS • .:Z<l4;). 1-,'\:~ E ZIP CODE C/';2.QQ 7r -~o -3 ADDRESS L7'i0 (\').,,._io~Ol-lf'-~\.lL. . ZIPCODE ':f:29?8 DAYTELEPHONE 7:2.Cf -~'- NAME CITY STATE ADDRESS ZIP CODE DAY TELEPHONE STATE UC. # LICENSE CLASS CITY BUSINESS UC. # Des1cNrn NAMEl<o-{ 'Q_:~~~ADDRess ~<l.42. l-\,-.,Qov-So S-c: ~ n:,;__ e: ?. ~ STATE Ce. ZIP CODE 12.ocfi DAY TELEPHONE ~STATE UC.# 7 j 40 Workers' Compensation Uedarat1on: I hereby affirm that I have a certificate of consent to self-msure issued by the Director of lndustnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO. EXPIRATION DATE Ceruhcate of Exempt10n: I certify that m the performance of the work for whtch thts permit 1s issued, I shall not employ any person m any manner so as to become subject to the Workers' Compensation laws of California. SIGNATURE DATE 8. oWNmt-BOllDF.k DFl!CARXliuN 0Wner-Bu1lder Oeciarat1on: I hereby affirm that I am exempt from the COntracto?s License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Ccxle: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's Llcense Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with concractor(s) licensed pursuant to the Contractor's Llcense law). □ I am exempt under Section ________ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's license Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500)). SIGNATURE DATE COMPLEIE IHIS SECIION FOR NON-RESIDEN IIAL BUILDING FERMI IS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely ha1.ardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Ha1.ardous Substance Account Act? □YES □NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □YES □NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □YES □NO IF ANY OF TIIEANSWERS ARE YFS, A FINAL CERTIFICATE OFoa:IJPANCY MAY NOT Bl! ISSUED AFTER JULY 1, 1989 UNU!SS THE APPLICANT HAS Ml!T OR IS MEIITING THE REQUIREMENTS OF TIIE OFFICE OF EMERGENCY SERVICES AND THE AIR POLUJTION ffiNTII.OL DISl1UCT. 9. WNSIROCIION LENDING ACF.NCI I hereby athrm mac there 1s a construcnon lendmg agency for the perlormance of uie work for which this permu 1s issued (Sec 309?(!) Civil Code). LENDER'S NAME LENDER'S ADDRESS IO. APPIJCXNI CP.klMCAliON I certify that I have read the apphcat10n and state that the above mformatmn 1s correct. I agree to comply with all City ordmances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I AISO AGREE TO SAVE INDEMNIFY AND KEEP IIARMIBSS TIIE CTlY OF CARISBAD AGAINSf AU. UABIIJTIES, JUDGMENTS, cnsrs AND EXPENSES WHIOI MAY IN ANY WAY ACX:RUE AGAINSf SAID CTlY IN ffiNSEQUENCE OF TIIE GRANTING OF TIIlS PERMIT. OSHA: An OSHA permic is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issu the Building Official under the provisions of this Code shall expire by limitation and become null and void if the by sue permit is not commenced within 365 days from the date of such permit or if the building or work authorized by ed at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). DATE: 7-11=1 , YEIJ.OW: Applicant PINK: Finance CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB911048 FOR 11/26/91 DESCRIPTION: 90 SF STORAGE+ 296 SF RAD+ 443 SF GARAGE (LEGALIZE SOME EXISTING) TYPE: RADMAJ STR: JOB ADDRESS: 1790 MAGNOLIA AV APPLICANT: JOEL ROGERS PHONE: 729-0553 PHONE: ---~~"--------------- INSPECTOR AREA MP PLANCK# CB911048 OCC GRP CONSTR. TYPE VN FL: STE: CONTRACTOR: OWNER: MOE, LEWIS AND JULIE REMARKS: MH/LOREN/747-9847 SPECIAL INSTRUCT: PHONE: p, ( INSPECTOR J1v~~ TOTAL TIME: LVL DESCRIPTION ACT COMMENTS CD 19 29 39 49 ST Final Structural -AP----------------PL Final Plumbing ~ EL Final Electrical ME _F_i_n_a_1_M_e_c_h_a_n_i_c_a_1_______ _ _____________ _ ------------------------------------ ***** INSPECTION HISTORY***** DATE DESCRIPTION ACT INSP COMMENTS 110791 Interior Lath/Drywall AP MP 103191 Rough Combo AP MP 102291 Roof/Reroof AP MP 100891 Ftg/Foundation/Piers AP MP 10/7/91 BY P.O. 100791 Ftg/Foundation/Piers AP PD 100491 Ftg/Foundation/Piers NR MP DATE: ESGIL CORPORATION 8-?0 -9/ 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 ISDICTION JURISDICTION: CfT'J OF ...1 A KER PLAN CHECK NO: <=, I -/O(J,{l SET: 1[ □FILE COPY □UPS C,DESIGNER PROJECT ADDRESS:_~/7.:......cj_O:...__~H.:...14:..:...::b:.......::clv~o~L~/~/'r--'----'-'4-c~r/=~--- PROJECT NAME : -=s'-'f__,D"'---'-8:,._,0"'o"'-'-''N'--_tl-'-, __ e_e=---H'--'o:::..,Dec.a,='-----'-Ftl--'--e...= □ □ □ □ □ cJ I Lt?wl<;. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _____________ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check The plans plans are list transmitted herewith is for your information. are being held at Esgil Corp. until corrected submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: ~ Esgil staff did not advise the applicant contact person that plan check has been completed. O Esgil staff did advise applicant that the plan check has been completed. Person contacted: ____ • ________ _ Date contacted: ________ _ Telephone# ________ _ □ REMARKS: ______________________ _ By: fH?€ DO(,../tF/JTIF ESGIL CORPORATION □GA UAA ORN ODM Enclosures: ----------- fl-Z.7-"!I r . ' ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92.123 (6 I 9) 560-i 4-£8 DATE: :2..-9/ JURISDICTION: CARLSBAD PLAN CHECK NO: SET: 1 PROJECT ADDRESS: / 7 q o 1---1 /4-6NOi... I 14-/Cr-Vt? PROJECT NAME: SF.I) f+oo't.J ?, e.~Hc)D(FL, Fo.«.. D D D D LG1'V/S ~ ..J(,11..J/S"' lv!O~ I The plans transmitted herewith have been ~orrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's ~uilding codes when minor deficien- cies identified--~----------are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check The plans plans are list transmitted herewith is for your information. are being held at Esgil Corp. until corrected submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. 18) The applicant's copy of the check list has been sent to: R'.Dlj R-, Bt.Aei=..F'ot:.D t±A:?DI .fJ(.-, S.T Esgil staff did not advise the applicant contact person that plan check has been completed. O Esgil staff did advise applicant that the plan check has been completed. Person contacted: ____________ _ Date contacted: ---------Telephone# ________ _ □ REMARKS: ______________________ _ By: ft6E Pt>L!t?IUTtc ESGIL CORPORATION □GA □AA ORN OnM Enclosures: __________ _ 7-3()-Cf/ !'LAH CH11CK NO: __ q....:....:./_-_I_O_ll--.:.....=.f! ____ _ JURISDICTIOll:~CI=I_.1-'0"'Y---"CARLSBAD===------- l'O: !?01 2Pf4-Z. P, ENCLOSIJRES: ________________ _ PROJEC'.[ ADDRESS: _____________ _ I 7~ 0 10146NOL! A- eo•J;J e tzJ;.1 r) ,J FLOOR AREA: :z.__q (,,, -t sroRIES: __________________ _ HEIGHr: _________________ _ R!MARKS: !'LAH CORRl!CTIOII sm:t:r CilY OF f:tW WP S:rMllE V~Y AIID llOPLEX llWELLIIIGS Date plans received by jurisdiction: Date plans received by Esgil Corporation: 7-?D-"t/ Date initial plan check completed: l?-Z-"f/ By: frB': DOLtGIJTI: Applicant contact person: ~ P.P'1 P', 8i.adhc:.telephon -§IV 7-z,q -oSS5 Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1988 UBC (eff. 1/1/90) 1988 UPC (eff. 1/1/90) 1990 NEC (eff. 7/1/91) 1988 UMC (eff. 1/1/90) The above regulations construction, regardless adopted by ordinance. apply to residential of the code editions Toe circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed i.e., plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. IICJIE: PAGE 1U111ERS ARE IIOT Ill SEQ1JENCE AS PAGES BAVIIIG NO I"Il!NS IIEEDIIIG CXlRR!X:'ITOIIS WERE DELE:tED. List No. 12, carlsbad Single Family Dwelling and Duplex With All Supplements. (1988 UBC) .Y. ✓. 5. /. Please r..ake all corrections on the original tracings and submit t1,.,•o new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Olesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. Indicate on the Title Sheet of the plans, the narie of the legal o-..,,ner and name of person responsible for the preparation of the plans. Section 302(a)7. All sheets of plans oust be signed by the person responsible for their preparation. (California Business and Professions Code). 5 IZIZ B B..o w Plans, specifications and calculations shall be signed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional -..ood frame construction. Specify expiration date of license. (California Business and Professions Code). Specify on the Title Sheet of the plans the gross floor area of each element of this project including d"'·elling., garage., carport., patio, deck and balcony. Section 302(d). Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC and UPC and 1990 NEC. Submit fully dimensioned plot plan drawn to scale showing location., size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes. Show finish floor elevations and show elevations of adjacent finish grade. Show drainage patterns with minimum slopes. Section 302(d). /. Indicate distance proposed building. from property Section 302(d). lines to 7 /9/91 Show on the title sheet all structures, pools., walls., etc. included under this application. Any portion of the project shown on the site plOJJ that is not included with the building permit application filed should be clearly identified as "not included.11 Clearly show if the lower level is a basement or a story., based on the definitions in Sections 403 and 420. Plot the finish grade (as defined} on the elevations and dimension the distance to the floor above., for story determination. On the cover sheet of the plans., specify any items requiring special inspection., in a format similar to that sho'\,1J'l, below or sticky back. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections., the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM SOILS COMPLIA!,CE PRIOR TO FOUNDATION INSP. STRUCTURAL CONCREIE OVER 2500 PSI PRESTRESSED STEEL FIELD WELDING HIGH STRENGTH BOLTS EX'PANSION ANCHORS SPECIAL MASONRY SPRAYED ON FIRE PROOFING PILES/CAISSONS DESIGNER-SPECIFIED OTHER REQ. IF CHECKED rn PROllLIIOK REMARKS /, Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings. Table 5-A. 2 G 0 ;{. Exterior walls closer than 3 feet to a property line shall have 30 inch parapets when the floor area per floor exceeds 1,000 square feet. Section 1709. Projections, including more than 12 inches from the property line. eaves, may not extend into the 3 foot setback Section 1710. Eaves over required windows than 30 inches from the side lines. Section 504. shall be not less and rear property Plastic skylights shall not be installed within that portion of a roof located within a distance to property line where openings in exterior walls are prohibited or required to be protected. Section 5207 (°a). 7. Projections, including eaves, shall be one- hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 31 setback area from the property line. Section 1710. Show location of permanently wired smoke detector: a. Centrally located in corridor or area giving access to sleeping rooms. b. On each story. c. In the basement. d. When sleeping rooms are upstairs, at the upper level in close proximity to the stair. e. In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 1210 When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided at existing bedrooms per item 19 above. Section 1210. Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area. At least one room shall have not less than 120 square feet of floor area. Section 1207 {b). Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (a). Appears to be deficient in 2/12/90 /s. 0 0 Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required and minimum is 1.5 sq. ft. Section 1205 (a). At least 1/2 of the common wall must be open and have an opening not less than 25 sq. ft. nor one tenth of the floor area of the interior room if light and ventilation is being supplied from an adjacent room. Section 1205 (a). Required windows shall not open into a roofed porch unless the ceiling height is at least 7 feet, the longer side is at least 65% open, and the porch abuts a street, yard or court. Section 1205 (a). Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. Section 1205 ( c). Show discharge point for exhaust air to be at least 5 feet from any oechanical ventilating intake. Section 1205(c). Ductless fans cannot be used in bathroocs if a tub or shower is present. Section 1205(c). No habitable room, be less than 7 1011 1207 (c). other than a kitchen, shall in any dimension. Section Show that ceiling height for habitable rooms is a minimum of 7 1611 • Section 1297 (a). Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'0". Section 1207 (a). Dimension on the plans the 3011 clear width for water closet compartments and 2411 clearance in front of water closet. Section 511 (a). Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to doors and glazing adjacent to walking surfaces. Section 5406. Glazing, in the same wall plane must be safety glazing if within door and less than 6011 above surface, unless the glazing is faceted glass. Section 5406 {d) 6. as a door, 12" of the the walking leaded or Glazing in shower and tub enclosures tempered, laminated or approved (including windows within 5 feet of shower floor). Section 5406 {d) 5. 3 shall be plastic tub or 1'- I /z. 13· Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 4411 above the floor. The window must have an openable area of at least 5.7 square feet ""ith the minicum openable width 2011 and the minimum openable height 2411 • Section 1204. Basements in d\,;elling units shall comly with the above (even if not designated as sleeping rooms). Section 1204. ~alls and floors separating units in a duplex fire-resistive shall be of one-hour construction. Section 1202(b). A mezzanine is an intermediate floor and may not have a floor area exceeding 33 1/3 percent of the total floor area in tile room below, The mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 4211 in height. Section 1716. The loft you mezzanine floor Code definition, show does not comply as a a.~d is, by Uniform BuilGi~g a story. Section 1716. EXITS, STAIRWAYS, AND RAILINGS Floors above the second story shall have not less than 2 exits. Exceptions: 1. Occupied roofs may have one exit if such occupied areas are less than 500 square feet and located no higher than immediately above the second story. 2. When the third floor wit.."iin a unit does not -exceed 500 sq. ft., only one exit need be provided. Section 3303(a). Required exit doorways shall be not less than 3611 in width and not less than 61811 in height, and shall be capable of opening at least 90 degrees. Section 3304 (f). Provide 3611 high protective railing for porches, balconies, ,and. open sides of stair landings. Openings between railings shall be less than 611 • Section 1711. Show how guardrail connection details are adequate to support 20· pounds ··per· lineal foot at a right angle to the top rail. Table 23-B. 5/10/90 1.r/" .Provide stairway and landing details. Section 7· 3306 (b), (c) and (p). t f· a. Maximum rise is 711 and minimum nm is 1111 • When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8° maxir.rum and nm 911 min ir.nJ.n • b. MinimuI:J headroom is 6' -811 • c. Minim'.JI:J width is 3611 • All handrails per Section 3306 (.j), shall satisfy the following: a. Provide handrail for stairways with 4 or more risers. b. Handrail shall be 34" to 3811 above the nosing of treads. c. The handgrip portion of handrail shall be not less than l 1/2"~ nor more than 211 in cross-sectional di.I!le~siort. Every stain-:ay la."lding shall l'-..aYe a dimension, measured in the direction of travel, at least equal to the stairway wid.th. Such dimension need not exceed 36 inches. Section 3306 (g), 3304 (.i). An interior door may open inward at the top step of a stain-·ay provided the top step is not more than 7 1/211 lower than the floor level. Section 3304 (i). Provide details of winding stairway complying with Section 3306 (d): a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from where the treads are narrowest. b. Maximum rise is 8 inches. c. Minimum width is 36 inches. 4 I I Provide spiral stairway details, per Section 3306 (f): a. Mini.mum nm is 7 1/2 inches measured at a point 12 inches from where the treads are the narrowest. b. Maximum rise is 9 1/2 inches. Maximum clear opening between risers is 6 inches. c. Minimum headroom is 6 feet 8 inches d. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. Spiral stairways may not be used for required exits when the area served is greater than 400 sq. ft. Section 3306 (f). Provide I.C.B.O. Research Report and number fo'r metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stair;;ay fabrication plans shall be submitted to and approved by the building official prior to installation. Exterior stair..·ays shall not project into the 3 foot setback from the property lines. Section 3306 (n). lbe walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m). Within units, show that minimum wid.th of 36 inches. ROOFING Specify roof slope. corridors have a Section 3305 (b). Roof slope specified. is not adequate for Table 32-B,C,D and E. roof type Specify roof material and application. Chapter 32. Specify I.C.B.O. or U.L. approval nwnber for roof materials not covered in U.B.C., e.g., tile, etc. Section 107. Specify minimum 1/4 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a) and Section 2305 (f). Show roof drains and overflows. Section 3207. 12/18/90 ® 0 Provide skylight details with Sections 3401 and I.C.B.O. approval number. to show compliance 5207 or provide Plastic skylights must be separated from each other by at least 4 feet. Section 5207 (a) 6. Show attic ventilation. Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). KASOIIRY Provide fireplace construction to standard drawing. construction details or note be per attached fireplace Chapter 37. Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)l and Section 2515 (a). Show ties and #9 wire in horizontal joints. Show height and construction details of all masonry walls. Chapter 24. Show floor and roof connections to ma.sor.ry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. Show a minimum 211 air space and flashing between planter and building walls. Section 2516 (c) 7. GARAGE AIID CARPOR:rS Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 5-B, Section 503 (d). All elements supporting floor above garage, including walls supporting floor joists, must have one-hour fire-resistive protection on the garage side. Section 503 (b) Show l 3/811 solid core self-closing door for openings between garage and dwelling. Section 503 (d). Garages are not permitted to open into a room used for sleeping purposes. Section 1104. 5 I I I 0 I An occupancy carport and open on two uses above. Show garage over garage plate line, holddo"ns if separation is not required between residence, provided the carport is or more sides and has no enclosed Section 503 (a) Exception 3. framing sections, size of header opening, lateral cross bracing at method bracing garage front and required. Chapter 23. NOTE: Maximum shear panel height-to-width ratio is 3 1/2 to 1 for plywood. Table· 25-1. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 3304 (i). Provide an 1811 raised platform for any FAU, water heater, or other device in the garage which may generate a flame or spark. UMC Section 508, UPC Section 1310 (a). FOUNDATIO!I ~ Per soils report, note on the plan the soils classification, whether or not tile soil is e>.-pansive and note the allowable bearing value. Section 2905 (c). The foundation plan does not comply with the soils report recommendations for this project. Please review the report and modify design, notes and details as required to show compliance: ________________ _ Provide notes on the foundation plan listing the soils report recommendation for foundations, slab and building pad preparation. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). 2/13/90 y y recommended that he/she The soils engineer review the foundation ·the foundation plan contractor requesting foundation inspection, shall advise the building that: excavations. Note on that 11Prior to the a Building Department the soils engineer official in writing 1. The building pad was prepared in accordance with the soils report, 2. The utility trenches have been properly backfilled and compacted, and 3. The foundation excavations comply with the intent of the soils report". Show height of all foundation walls. Chapter 23. Show height of retained earth on all foW1dation walls. Chapter 23. If cut or fill slopes exist, foundation to edge of cut or show steepness and heights of Chapter 29. show distance of fill slopes and cuts and fills. Note on plans that above finish grade. wood shall be 611 ciinlJD",J.Jl Section 2907 (a). Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Section 2905 {f). Dimension foundation per U.B.C. Table 29A: Floors Footing SUI!;J20rted,'t Stemwall Width Depth Thickness l 6" 1211 1211 2 B" 1511 1811 3 1011 1811 2411 ,',Foundations may support a roof in floors. Where only a roof is foundation for one floor. 6" 7" 8" addition to the supported, use Y· Show foundation sills to be pressure treated, or equal. Section 2516 (c) 3. 9r;J( Show foundation bolt size and spacing. ( -. Section 2907 (f). __ / Specify size, I.C.B.O. number and manufacturer Jr· of power driven pins • Show edge and end distances and spacing. Section 302 (d). 6 ?f. If required, show size, embedment and location of. hold dos-n anchors on foundation plan. Section 302 (d). If hold do¥tns are required, note on plan that hold do¥t'Il anchors must be tied in place prior to foundation inspection. Section 305 {e) 1. Sho\l adequate footings under all bearing walls and shear s·alls. Section 2907 (b). Show on the plans stepped footings for slopes steeper than 1:10. Section 2907 (c). Show minimum 1811 -Clearance from grade to bottom of floor joists and minimum 1211 clearance to bottom of girders. Section 2516 (c) 2. Show pier size, spacing and depth into undisturbed soil. Table 29-A; ShO\o" minimum underfloor access of 1811 x 2411 • Section 2516 (c). 9f Show minii.n.u:i underfloor ventilation equal to 1 ' sq. ft. for each 150 sq. ft. of underfloor area. Openings shall be as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c) 6. / 1)30. Show "''al 1 bracing. Every exterior wood stud wall and main cross-stud partition shall be braced at each end at least every 25 feet of length with l x 4 diagonal let-in braces or equivalent. Section 2517 (g) 3, Table 25-V. I 101. /i. In 2-story buildings, shear panels at the first story (at least 48 inches in ~idth) shall be located at each end or as near thereto as possible and comprise at least 25 percent of the linear length of the s·all, or provide design. Section 2517(g)3, Table 25-V. Note cross bridging or blocking. Floor joists and rafters 12" or more in depth shall be supported lateral.ly by bridging at intervals not exceeding 8 feet, unless both edges are held inline. Sec. 2506 (h), 2517 (d) 6. Show blocking at ends and at supports ·of floor joists, rafters and trusses at exterior walls. Section 2517 (d) 3, 2517 (h) 6. Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, "''alls or partitions, more than the clepth of the joist. Section 2517 (d) 5. 7/6/91 1· f Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just abqve the ceiling joists, "''here rafters and ceiring joists are not parallel. Section 2517 (h) 4. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h) 5. Show double top plate with minimum 4811 lap splice. Section 2517 (g) 2. Show nailing will be in compliance "''ith Table 25-Q. 1oy. Show or note fire stops at the follo.,,,·ing / locations per Section 2516 (f): a. In concealed spaces of stud ...-alls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot inten·als along the length of the ..,.all; b. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; c. In concealed spaces between stair stringers at the top and bottom of the run and between studs along and inline with the run of stairs if the ..,.alls under the stairs are unfinished; and d. In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, ~ith noncombustible materials. In duplexes, draft stops shall be provided in floor-ceiling assemblies and attics in line with walls separating units and separating units from common areasa Show stud size and spacing. Maximum allo~able stud heights: Bearing wall: 2 x4 and 2 x 6 max. 10'; Non-bearing: 2 x 4 max. 141 , 2 x 6 max. 20 1 • Table 25-R-3. Studs supporting two floors, a roof and ceiling must be 3 x 4 or 2 x 6 at 1611 o.c. Table 25-R-3. Note on A.I.I.C. Certificate of Compliance for glued laminated wood members shall be given to the building inspector prior to installation. Section 2505. 7 Detail all post-to-beam and post-to-footing connections and reference t.he detail to the plan. Section 2516 (m). 1/s. Detail shear transfer connections, including roof and floor diaphragms, to shear "''alls. Section 2513. I Specify nail size ,,:alls, floor and required blocking. dimension ratios. Section 4714 (d)]. and spacing for all shear roof diaphragms. Indicate Maintain maximum diaphragm [Tables 25 I, J, Kand Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Show 1/211 mini.mum clearance between top plate of interior partitions and bottom chord of trusses. (Io ensure loading Ydll be as designed). 119. Provide roof framing plan and floor framing plan. Section 302 (d). 120. Provide framing sections through Section 302 (d). /~ Specify all header sizes for openin~ over 41 V wide. Section 2517 (g) 5. <::/;;{£ '>Hee? I ~ r:? F -rife f'<-14-N> r 122. Provide calculations for main vertical and ✓ horizontal framing members and post footings. ;'3. ,i.l5. Section 302 (b). Provide calculations for lateral loads, shear panels) shear transfer and related. Section 302 (b. In Seismic Zones 3 and 4, the allowable shear wall values for drywall in Table 47-I must be reduced 50 percent when considering earthquake loads. This does not apply to wind loads. Footnote 1. Show on the plans developed in the Section 302 (d). end.) all structural requirements structural calculations. (See comments below or at 7/5/91 ys. Columns and posts located on concrete or masonry floors or decks exposed to the weather or•to water splash or in basements and vhich support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. Individual concrete or masonry piers shall project at least 8 inches above exposed groWld unless the columns or posts "''hich they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. Show location of attic access siz.e 22 11 x 3011 • Section 3205. with minimum Show draft separation for attic areas between units in a duplex. Section 2516 (f). Specify plywood thickness, grade index. Table 25-S. and/or particle board and panel identification When roof pitch ridge as a beam. is less than 3:12, design Section 2517 (h). If foundation cripple wall studs are less than 1411 high, framing shall be solid blocking, or sheathed with plywood. Section 2517 (g) 4. Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517., (g) 4. Show plywood sheathing over exposed eaves, or other weather exposed areas, is 11bonded with exterior glue.11 Plywood used for exterior wall covering shall be the exterior type. Section 2516 li), 2516(g)3. Detail truss layout for 3011 x 3011 attic access, if required for equipment in the attic and detail 3011 x 3011 clearance through truss webs. Ridges, hips, and valleys shall be at least one size larger than supported rafters. Section 2517 (h) 3. Y7· In open beam across the Section 2501 construction, provide strap ties beams at the ridge support. (b). 8 1-.A..-Note on the plans that "all weather-exposed /.... surfaces shall have a 1,,:eather-resistive barrier to protect the interior ~all covering and that exterior openings shall be flashed in such a manner as to make them \,:eatherproof11 • Section 1707. HEC!All)'.CAL (UIIIF'ORH HECIIAJIICAL CODE) All heating, ventilating, and cooling systems and appliances shall comply with the Uniforn Mechanical Code. Show the size, location and type of all heating and cooling appliances or systems. Every dwelling unit shall be provided with heating facilities capable·· of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Sec. 1212. Note on the plans t.hat the FAU closet or alcove nrJst be 12 inches ~ider than the furnace or furnaces being installed. U'MC Section 704. tC2. Show rninir.n.u:::I 3011 deep unobstructed working space in front of furnace. Section SOS, UMC. l~. ' Y'5· ~- 0- Furnace shall not be installed in any bedroom, bathroom or in a closet or confined space wit.h access only through such room unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UHC. Show source of combustion air to furnace, per Chapter 6, UHC. Show access to the attic containing equipment to be minimum 30 inches by 30 inches. The opening may be 22 inches by 30 inches if the equipment can be removed through such opening. Section 708 UHC. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide, not more than 20 feet in length through the attic. Section 708 UHC. Show penoanent electrical outlet and lighting fixture controlled by a switch for furnace located in attic or underfloor space. Section 708 & 709 UHC. 1,£. Show details to comply with Section 709 for furnace under the floor, or Section 710 for roof or outside furnace. 7/9/91 a Show I.C.B.O. approval number for prefab V fireplace. Show height of chimney above roof ,lh per I.C.B.O. approval o~ Table 37-B~ '[C-50 ,uv ~ /S°',7 f';, /JD l--D/JG!Efi=. i/ffLID · 1 • Not~ on plan: Gas vents and non-combustible piping, in walls, passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC, Section 1706 (a) 6. Q Provide dryer vent to outside. UMC, Section v 1903. ELECl:RICAL (HAnOIIAL ELECTRICAL CODE) All w1r1ng shall comply with the National Electrical Code. ~- µ{. .£. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub- panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. I 00 14H p , Note on the plans: 11Electrical outlets shall be installed in accordance with NEC Article 210-52". Note on the plans: "Lighting outlets controlled by a wall switch shall be provided in accordance ..,·ith :NEC Article 210-7011 • Note on the plans: 11Light fixtures installed in clothes closets "'"ill comply "'"ith NEC Article 410-811 • Note convenience outlets in bathrooms, kitchen counter top(s) within 6 feet of the kitchen sink, outdoors, and in garages and basements (other than for laundry and similar equipment) shall be GFI protected. NEC, Art. 210-8. Note electrical system ground to be provided per NEC, Art. 250-SO(a), 8l(c). ,z,c,s,1G, PLUHBDIG (llJIIFORH PUJKBDIG CODE) Show water heater size, type and location on plans. UPC, Section 1301. Show source for providing combustion air to fuel burning water heater. If wall openings in an enclosure are used, at least one-half of the required opening area shall extend into the upper twelve inches of the enclosure and one-half within the lower twelve inches. UPC, Section 1307. 9 ~-Fuel combustion water installed in bath or opening into bath or 1309, heater shall not be bedroom or in a closet bedroom. UPC, Section Provide adequate barrier to protect water heater from vehicle damage. An 1811 platform for the water heater does not satisfy this requirement. UPC, Section 1310. Q Show T and P valve on water heater and show CJ route of discharge line to exterior. UPC, Section 1007 (e). Ll Show that water heater is adequately braced to V resist seismic forces, when not connected by rigid pipe. UMC Section 504(d). 1yf. iy£. ~- fa. Show shower stall can accommodate a 3011 circle and has a m1.nl.ll!lllD floor area of 1,021+ sq. in. UPC 909 (d). Provide clothes washer hook-up for each unit. Title 24, Part 3, NOISE l!ISIILATIOII (DUPLEXES l Show details of duplex co111Don (party) walls and floor/ceiling assemblies to achieve a Sowtd Transmission Class (SIC) rating in walls of 50 decibels and an Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibels. Title 24. Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 24. Provide insulation in walls and ceiling to achieve STC of 50 between garage and living area if garage use is not control led by resident. Title 24. 1~. Provide plans, calculations and worksheets to T-show compliance with current energy standards. Q The regulations require a properly completed V and properly signed Fom CF-lR to be either imprinted on the plans, taped to the plans or "sticky backed11 on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the.approved energx design. OWA)~ /.,/u.o.T 8 c;i,-IJ c.P-11.:c . Specify on the building plans all of the ~datory energy conservation requirements as listed on the enclosure titled, "Mandatory Energy Conservation Reguirements11 • efficiency of the system and provide the output exceeds y{ Show the make, model and space heating (or cooling) heat loss calculations if 45,000 BTU/Hr. a For room additions, show that the glazing area V of the addition does not exceed 16% of the newly-conditioned floor area, plus glazing removed or relocated due to the addition. Q Provide fluorescent general lighting in V kitchen(s) per CAC, Title 24, 2-5352(J). CARLSBAD S.F.D. & OOPLKX SUPPL!HEllr y/. Energy conservation design should be for Zone 7. f,. Floor drains must have auto-prime (city policy). .,/a. For gas piping under slabs that serve kitchen island cooktops, see the attached Policy 91-46 for special sleeve and clean-out requirements. f'::::\ Note exhaust fans cannot be ductless type V (city policy). ~ New residential units must be pre-plumbed for future solar water heating. Note 11two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof {City Ordinance No. 8093). Ci\ Note "two 3/411 copper pipes must be installed V to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 8093). a All piping for present or future solar water CJ heating must be insulated when in areas that are not heated or cooled by mechanical means (city policy), /a3. Incorporate the waterproofing details, on the attached Policy 80-B, where interior living space occurs below grade at the masonry wall(s). W Show on the Title Sheet on the plans, the CJ information required by the attached Developmental Services Sheet 112383. All energy items shown on the plans must be in agreement with the information shown on the properly completed Fom CF-lR, ';;ft-01,./ ,;It;-,= !:51 'D I /J! "-I., ~ TI D iJ <n..J -nlf; X -S f'c-7'1 J lj ( I ,J 7 /10/91 10 ip, All new residential buildings, including additions, require a soils report. Please submit two copies. Exception: If a room addition is limited to one story and 1000 sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the City to place their soils notice stamp on the plans. 1,t: Heavy timber framing, minimum 6" x 1011 beams and minimum 8" x 8" post, for the structural beam and colwml supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). p{. All structures require a Class B roof covering, except room additions. ~ If a room addition covers all of the existing building (2nd story addition), then the above exception doesn1t apply. City Ordinance 9792 spaces/unit with clear washing machines, etc. requires two parking area of 20'x201 i.e. no Show compliance. All chimneys attached to any appliance or fireplace that burns solid fuel shall be equipped with an approved spark arrester. The net free area of the spark arrester shall be not less than four times the net free ara of the outlet of the chimney. The spark arrester screen shall have heat and corrosion resistance equivalent to 12 gauge wire, 19 gauge galvanized wire or 24 gauge stainless steel. Openings shall not permit the passage of spheres having a diameter larger than 1/2-inch and shall not block the passage of spheres having a diameter of less than 3/8-inch. KISCELLAIIB'.XIS W Please see additional corrections, or remarks, Von the following page. ~ To speed up the recheck process, note on this V list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. W Please indicate here if any changes have been V made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. ____ Yes _____ No 10 91 The City of carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite io8, San Diego, California 92123; telephone number 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact. ________ _ at Esgil Corporation. If you have any questions regarding City Building permit procedures, please contact carter Darnell at the City of carlsbad, 2075 Las Palmas Dr., telephone 619/438-1161. Thank you. Enclosures: 1. 2. 3. F!2of)T 11 Jurisdiction _ _,_CuAR=r~,s~B~AwD.._ __ Date I g/z./ 9 / Prepared by, R-BG VALUATION AND PLAN CHECK FEE □ Bldg, Dept. D Esgil PLAN CHECK NO, __ q~1~-_I_O_t./-,i'-'-_ BUILDING ADDRESS _:....17:....1.:....=..D_..:.M--'-'-'A-'-"G:..:.N~O=L'-'/l't-=-----'-M~~-------=---,------ APPLICANT/CONTACT ~R.o-'----JlJ~~,e-'-,_f3~l./4C-'-~£!.~F'O~~-PHONE NO, {f,t<t) 7 2-'t -OS'S 3 BUILDING OCCUPANCY ___ £_--~~L~tf.'-1--DESIGNER PHONE _____ _ TYPE OF CONSTRUCTION i/-;J CONTRACTOR PHONE ----- BUILDING PORTION BUILDING AREA VALUATION VALUE 11:ULTIPLIER /Jrf)[?1--rfOA J( c'<•ST6. 50-3 75, DO </--!, o 99 61"rtzPr(....,='° tJ...-t./-3 1g,(5?) 7. c; 7tJ... ' - Air Conditionin1< Commercial @ -. Residential ia Res. or Comm. Fire S'llrinklers @ Total Value 4-11 073 B uildirig Permit fee $ __________________ --"-s_4..,_.,_/_c/--'-·_, _51.) __ _ Plan Check f ••-S=-------------------~$ __ .2..,,_{,;,_7''-'-, _t:f-,-3 __ _ CO 11 11 ENT S,._: ---------------------------- SHEET_~OF~-12/87 ~ I .. • OJ. ,--~ QI I BUILDING PLANCHECK .)"- ~ ' t\. ENGINEERING CHECKLIST -::> ..... ~ <( ~DATE: 7 --I ~ ITEM COMPLETE , r 1-7 W, u w 0.... c,., ~ <( 1 2 3 s N R .T D D C C C H H H E E E g K K □□ PLAN CHECK NO. ~ e 9 I -I (J L~ 9-. LEGAL REQUIREMENTS Site Plan 1. ITEM INCOMPLETE NEEDS YOUR ACTION ITEM SELECTED ~do 2. Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimension setbacks. Show on site ~plan: @Fish floor elevation~ <..ad elevations, elevations of finish grade adjacent --t_o □□□ 3. uil ing, existing topographical lines, existing and proposed slopes, driveway with percent ( % ) grade and drainage patterns. Provide legal description and Assessors Parcel Number. cd □□ Discretionary Approval Compliance 4 • No Discretionary approvals were required. □□□ 5. Project complies with all Engineering Conditions of Approval for Project No. ________ _ □□□ 6. Project does not comply with the following Engineering Conditions of Approval for Project No. _________ _ Conditions complied with by: ________ Date: ____ _ Field Review □□□ 7. ~□□ 8. ~□□ □□□ ~□□ Field review completed. No issues raised. Field review completed. The following issues or discrepancies with the site plan were found: A. B. c. Site lacks adequate public improvements Existing drainage improvements not shown or in conflict with site plan. Site is served by overhead power lines. P:\DOCS\MISFORMS\FRM0010.0H REV. 02/27/91 □□□ D. Grading is required to access site, create pad or provide for ultimate street improvement. 000 E. Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. 000 F . Other: ________________________ _ □□□ ~□□ Dedication Requirements 9. 10. No dedication required. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8\" x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s} prior to issuance of Building Permit. The description of the dedication is as follows: --------------- s \TE -p A l PR.O I () s ~ ~ A Ir) (') {'} F tll'YT 11 1 1(?..f:. 'r Dedication completed, Date _________ _ By: __ _ Improvement Requirements D DD 11. No public improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City inspector prior to occupancy. Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered civil Engineer prepare appropriate improvement plans and submit for separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are: ___ _ Improvement plans signed, Date: _________ by: ___ _ P:\OOCS\MISFORMS\FRM0010.0H REV. 02/27 /91 DD D 13a. do □ 14. 0 0 0 15. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting def err al of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date: ______ _ By: __________ _ Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). No grading required as determined by the information provided on the site plan. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department . NOTE: The Grading Permit must be issued and grading substantially complete and found acceptable to the City Inspector prior to issuance of Building Permits. Grading Inspector sign off. Date: ______ by: ____ _ Miscellaneous Permits fill □□ □□□ do □ □□□ 16. 17. 18 . 19. cii □□ 20. Right-of-Way Permit not required. Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the following: ______________________ _ Sewer Permit is not required. Sewer Permit is required. A sewer Permit is requi red concurrent with Building Permit issuance. The fee required is noted below in the fees section. Industrial Waste Permit is not required. P:\DOCS\MISFORMS\FRM0010.0H REV. 02/27 /91 ~~, D D D 21. Industrial Waste Permit is required. Applicant must □ □ □ □ □ □ complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Building Permits. Permits must be issued prior to occupancy. Industrial Waster Permit accepted - Date: __________ By: _______________ _ Fees Required 27. Park-in-Lieu Fee Quadrant: _____ Fee per Unit: ______ _ Total Fees: __ _ 23. Traffic Impact Fee Fee Per Unit: __________ Total Fee: ____ _ 24. Bridge and Thorough fare Fee Fee Per Unit: __________ Total Fee: ____ _ 25. Public Facilities Fee required. 26. Facilities Management Fee Zone: ____ Fee: ___ _ 27. Sewer Fees Permit No. _______ EDU's ___ _ Benefit Area: ---------Fee: _______ _ 28. sewer Lateral Required: ______________ _ Fee: _______ _ 29. REMARKS: _~E~E~D-~~~-0~£.~R_E:_N_:j~~-~-R~E_P~o~P_T_-1 PATA f<_EQ f--uT U t2.. E f fVI PR._ov t PLEASE R.E.-~UBM IT PRO PE.'2..L '1 EKE COTE: FQ'To~E. IMPR.0\JEME1'.)T AG-R.E.E1'1El0T ENGINEERING AUTHORIZATION TO ISSUE PERMIT DATE: _ ........ ?_-_z__.i'-----9'...__I __ _ P:\DOCS\MISFORHS\FRM0010.DH REV . 02/27/91 !! • • ~ ~ G G G Q Q Q ~ I I ~ ~ ~ 1~ N ~ .. "' "' u u u ~..5 • • .c .c u u ~~ C C G G .. .. PLANNING CHECI<LlSf Plan Check No. ~-/tJlf<t Address Planner Dl"i~,J G,1 1 cl< (Name) APN: J.o, -~3 0 -/(, Phone 4:fs-1161 ext. ---''l-"'J_Z-'fl ___ _ Type of Project and Use _...:.R..i.:?s....L.,. _ _.eea,._,~"-"'J_,:.i./J _______ _ Zone ~-I Facilities Management Zone __ __,/ ___ _ Legend Item Complete □ Item Incomplete -Needs your action 1, 2, 3 Num.ber in circle indicates plancheck number where deficiency was identified Environmental Review Required: YES DATE OF COMPLETION: NO/TYPE __ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ________________________ _ Discretionary Action Required: YES NO /TYPE __ _ APPROVAI./RESO. NO. __ _ DATE: _____ _ PROJECT NO. ___ _ OTHER RELATED CASES: ____________________ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ________________________ _ I□ □ California Coastal Commission Permit Required: YES _ NO / DATE OF APPROVAL: ______________________ _ San Diego Coast District, 3111 Camino Del Rio South, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ________________________ _ ~ Landscape Plan Required: YES _ NO ~ :YC...O ~ u O □ ci"oo g/o D See attached submittal requirements for landscape plans Site Plan: Zoning: 1. 2. 3. 4. 1. 2. 3. 4. Provide a fully dimensioned site plan drawn to scale. Show: :--:er:;,. arrow, property lines, easements, existing and proposed struct'.lres. streets, existing street improvements, right-of-way width 3::: dimensioned setbacks. Show on Site Plan: Finish floor elevations, elevations or ,~rush :sra:.e adjacent to building, existing topographical lines, existing and ;;rc?cse·: slopes and driveway. Provide legal description of property. Provide assessor's parcel number. Setbacks: Front: [nt. '!:iide: Street Side: Rear: Lot coverage: Height: Required Required Required Required Required Required J.Q' Shown ,26' Z' Shown If' Iv>+-Shown /'llt /4 I Shown 5{,' '.z't?/. Shown L ~ 35"' Shown IO' Parking: Spaces Required 2 car~ Shown 2 ro.r r~,._,- G Req ' ed Shown "'0 " <" uest Spaces wr 0 0 0 Additional Comments ____________________ _ OK TO [SSUE AND ENTERED APPROVAL [NTO COMPUTER .fl).~ F DATE Z-.J. '/-Cf/ PLNCK.FRM .. KEN LONG -CIVIL ENGINEERING I0:32728 527 N. Hwy 101 (Sute BJ San Beach. CA 92075 (619] 481-7866 July 22, 1991 Ci.ty of, CQll,(,61.ad Bu,Ud~ng lrv.ipee,tion D~i.on 2075 L~ PIUl'IIIY.> D-\We CQ/1,(,61,ad, Ca Re: Lim«ed ~ lnue.4tigaUon P11.0,med Additi.on. 1790 Magnolia /\venue. ~ Ca A.P.N. 205-230-16 OwneM: Lewi6 8 J,d,,ie MOt!. On Ju{y 15,1991 native 60it ~6 cve-\e. oUa.ined at the 6u/,fect ¾te ap~ 3 l,e.et ~w eai¾ing g-\ade. a,t the .£oca-Uorv., 1hown on the ~ p.£ot puzn. The e,x-it,ting na-tive 60U conw..t~ of, top60il.6 ap~ one-hat/, f,oot tAfck unde,\,la,in ,Y £(:'Im £o=tional. 60U. Vi6ua-l eaamination and phy:,.ic.il, te6Wlg ~ thM 60U to ~ dallk '-\Own, £ine to medium g-w.iM4 ¾Uy 6and, non-~we. The UM£ie,d Sou Cl.a»il,,i.cati.on £o,i thM 60U it., SM. 7 aUe 29-B o& the Un-i.(,o,un. Bui-tding Code ~14 a '-ea wig capuc.ity of, 1500 ~& ( M&e a-UowaUe 60it p-teMwte) £o,i th-it.. ~ 0£ ~u. Due to the non-upan¾ve and den6e natu-te of, thit.i 60U, tota< 6e«Lement and di££eli- en,ti,a{, 6ett/.e.me.nt wiU k rrn.nima,t. The wauA taUe u,•1.0 ,wt encounte'led an,l it., antioipated to k at ~ depth. AU f,oot,ing6 £o,i one-¼1-\y ~\e.6 6hotd.d k f,ounded a miMmum of, 12 inche1 '-e.£ow adj aceM ~ g'l.ade. and have a rn,in,imum w-u:Uh. of, 12 ~-Both iii~ : and eaitell,w\ co~ l,oot,ing6 6hotd.d k ~ w-Wi a miMmum one #4 w,\ po:.itioned 3 -i.ricJie/.; awve the wtt.om of, the £coting and one #4 w,\ po-:,.itioned 3 indle-1 cleM. '-e.£ow &irw.ih (,too\. Conc-\e.te. 6l.aM-on-g-\ade. 6hotd.d k a minimum of, 3% inche6 in th,ichn,e~~ and 6hotd.d k 'leul/,o,wed with 6"d,"-#10/#10 welded W& me-m m,in,imum. • • ·fl .. KENNETH LONG • CIVIL ENGINEERING 527 N. Hwy. 101 (Suite E) SOLANA BEACH. CA 92075 Phone 481-7866 .. SHEETNO----"----OF __ ...__ __ CALCULATED 9y_.....,l..b,c.J.N:!..l,4I.-_ DATE 1-:ii-11 CHECKED ev_----=----OATe ___ _ SCALE .~_ 1,0' =t -"/0,,) I - --T£Mi HO!.t ~tAT!OIJ7 --.;· ♦ ~ ~ ~X~TIIJ'f ol!t-~of!.1 - R~~l17f."1t.t. -<i)-('tl/ilNP£/ZM1TTV) . -ADDlflot-1,S ) - --I II\ I' ~ ·"w~iR, : l,E'.:W\7 ~ Jl.ll,lf. l16E: - 17'10 "1~NOt..lA I.VE-- -iA~L,~13.6.D, tA I 1..z.00.e,· LE'.:ftA L. : ~AtT I~{, 1Hl\K LAl-1171, NJ .. 70 fT. of ?.'N. i1tf.'I' Ff. Of -5.W. I~ I. 08 fj. - ~f 1RAtT 'L,t,~. -A.P. l--1: ·1,0r;-,z;i,-lt,