HomeMy WebLinkAbout1790 Yada Pl; ; CBRA2018-0054; PermitPrint Date: 01/28/2020
Job Address: 1790 Vada Pl
Permit
{city of
Carlsbad
Permit No: CBRA2018-0054
Permit Type: BLDG-Associated Permit Resi Work Class:
Parcel No: 1562205800 Lot#:
Single Family Detached
5
Status:
Applied:
Closed -Fina led
03/13/2018
06/27/2019 Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
$484,362.26 Reference#: DEV02058
1
4.00
VADA FARM
Construction Type: VB
Bathrooms: 3.50
Orig. Plan Check#: PC2017-0048
Plan Check#:
Issued:
Permit
Finaled:
Inspector: MColl
Final
Inspection: 1/28/2020 2:43:37PM
Description: VADA FARM: PHASE 2 // LOT 5 // PLAN 2BR // 3,004 SF// 174 SF PATIO// 507 SF GARAGE// 49 SF PORCH
Applicant:
MARY NETTLES
5927 Priestly Dr, 110
Carlsbad, CA 92008-8800
760-918-2829
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Owner:
TRUST VADA FAMILY TRUST 03-12-90
1835 Buena Vista Way
CARLSBAD, CA 92008
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PARK IN-LIEU FEES SF DETACHED & DUPLEX: NW
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
TRAFFIC IMPACT Residential Single Fam. Outside CFD
WATER METER FEE 1" Displacement (P)
WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 5/8" Displacement
Total Fees: $40,393.73 Total Payments To Date: $40,393.73
Contractor:
CALIFORNIA WEST CONSTRUCTION INC
5927 Priestly Dr, 110
Carlsbad, CA 92008-8800
760-918-6768
Balance Due: $0.00
$1,992.75
$1,283.33
$66.00
$170.00
$92.00
$7,649.00
$182.00
$16,952.68
$20.00
$4,919.00
$960.00
$62.97
$246.00
$56.00
$3,390.00
$282.00
$1,932.00
$138.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0054)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner:
Work Class: Single Family Detached Issue Date: 06/27/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 05/11/2020 Address:
IVR Number: 10090
Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-18 Exterior 110637-2019
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
01/03/2020 0110312020 BLDG-Electric
Meter Release
115255-2020
Checklist Item
BLDG-Building Deficiency
BLOG-Gas Meter
Release
115256-2020
01/2812020 01/2812020 BLDG-Final
Inspection
January 28, 2020
Checklist Item
BLDG-Building Deficiency
117639-2020
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Shower/tubs
Cancelled per contractor
Except shower/tub area
Passed
COMMENTS
Complete entry door
Entry door
Passed
COMMENTS
Michael Collins
Michael Collins
EMR emailed to SDGE
Passed Michael Collins
COMMENTS
GMR emailed to SOGE
Passed Michael Collins
COMMENTS
TRUST YADA FAMILY TRUST
03-12-90
1790 Yada Pl
Carlsbad, CA 92008
Reinspection Complete
Passed
Yes
No
Yes
Complete
Passed
Yes
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page 3 of 3
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0054)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner: TRUST YADA FAMILY TRUST
03-12-90
Work Class: Single Family Detached Issue Date: 06/27/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 05/11/2020 Address: 1790 Yada Pl
IVR Number: 10090 Carlsbad, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Date Start Date
Reinspection Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 108877-2019 Partial Pass Michael Collins Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/30/2019 10/30/2019 BLDG-16 Insulation 109257-2019 Passed Michael Collins Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/05/2019 11/05/2019 BLDG-17 Interior 109804-2019 Partial Pass Michael Collins Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Except shower/tub area Yes
BLDG-18 Exterior 109802-2019 Partial Pass Michael Collins Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Complete entry door Yes
BLDG-23 109803-2019 Passed Michael Collins Complete
Gas/Test/Repairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/12/2019 11/12/2019 BLDG-17 Interior 110382-2019 Cancelled Michael Collins Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Cancelled per contractor No
BLDG-Building Deficiency Except shower/tub area Yes
11/13/2019 11/13/2019 BLDG-17 Interior 110638-2019 Passed Michael Collins Complete
Lath/Drywall
January 28, 2020 Page 2 of 3
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0054)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner:
Work Class: Single Family Detached Issue Date: 06/27/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 05/11/2020 Address:
IVR Number: 10090
Scheduled
Date
Actual
Start Date Inspection Type Inspection No.
07/03/2019 07/03/2019 BLDG-SW-Pre-Con 096540-2019
Checklist Item
BLDG-Building Deficiency
07/18/2019 07/18/2019 BLDG-21
Underground/Unde
rfloor Plumbing
098023-2019
Checklist Item
BLDG-Building Deficiency
BLDG-22
Sewer/Water
Service
098022-2019
Checklist Item
BLDG-Building Deficiency
07/30/2019 07/30/2019 BLDG-11
Foundatlon/Ftg/Pier
s (Rebar)
099081-2019
Checklist Item
BLDG-Building Deficiency
09/17/2019 09/17/2019 BLDG-15
Rool/ReRoof (Patio)
104405-2019
Checklist Item
BLDG-Building Deficiency
10/01/2019 10/01/2019 BLDG-13 Shear
Panels/HD (ok to
wrap)
106038-2019
Checklist Item
BLDG-Building Deficiency
10/17/2019 10/17/2019 BLDG-13 Shear
Panels/HD (ok to
wrap)
107856-2019
Checklist Item
BLDG-Building Deficiency
10/28/2019 10/28/2019 BLDG-27 Shower 109159-2019
Pan/Tubs
January 28, 2020
Inspection Status Primary Inspector
Passed Michael Collins
COMMENTS
Passed Michael Collins
COMMENTS
Waste to POC
Passed Michael Collins
COMMENTS
Waste to POC
Passed Michael Collins
COMMENTS
Ufer in place
Partial Pass Michael Collins
COMMENTS
Sheathing nailing only
Partial Pass Michael Collins
COMMENTS
Prelim insulation/shear at exterior siding
locations
Passed Peter Dreibelbis
COMMENTS
Prelim insulation/shear at exterior siding
locations
Passed Michael Collins
TRUST YADA FAMILY TRUST
03-12-90
1790 Yada Pl
Carlsbad, CA 92008
Reinspection Complete
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Complete
Passed
Yes
Complete
Page 1 ol 3
~~,
~ CITY OF RECORD COPY L.o-r 5 CBRA2018-0054
CARLSBAD 1790YADA PL
Building Division INSPECTION. RECORD VADA FARM: PHASE 2// LOT 5// PLAN 2BR//3,004 SF//
174 SF PATIO// 507 SF GARAGE// 49 SF PORCH
0 INSPECTION RECORD CARD WITH APPROVED
ANS MUST BE KEPT ON THE JOB
DEV02058
PC2017-0048
1562205800
4/18/2018
0"6u.L BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION
@ FOR BUILDING INSPECTION CALL: 760-602-2725
OR GO TO: www.carlsbadca.gov/Building AND CLICK OI\(
"Request Inspection· ' CBRA2018-0054
DATE:
If "YES" is checked below that Division's approval is required prio_r..t_o__r_e_q_u_Qsj:_i_i_:1g a Final Building Inspection. If you have any questions
please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to
760-602-8560, email to t,_l_cl ins ecti_9.J1s@,:;_a_,:!_5_b_a_d_c_a_.gp_y or bring in a COPY of this card to: :1635 Faraday Ave., Carlsbad.
IF MARKED "YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION
STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours
IF MARKED 'YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING
Fire Prevention 760-602-4660
Planning/Landscape 760-944-8463
CM&I fEngfneering Inspections) 760-438-3891
REINFORCED STEEL
#66 MASONRY PRE GROUT
□GROUT □ WALL DRAINS
TILT PANELS
#11 POUR STRIPS ---------+-----+-----#11 COLUMN FOOTINGS
#14
#15 ROOF SHEATHING
#13
#16 INSULATION
#18 EXl'ERIOR LATH
#17
□ SEWER & BL/CO □ P1/C0
UNDERGROUN ASTE~R
TOP OUT □ WASTE □ WTR
#27 TUB & SHOWER PAN
#23 □ GAS TEST □ GAS PIPING
#25 WATER HEATER
#28 SOLAR WATER
BLDG-FINAL
Com:::tt POOLS Date Ins ector
#51 POOL EXCAV / STEEL
#52 PLUMBING
#53 ELEC /CONDUIT/WIRING
, EQUIPOTENTIAL BOND
',.,/ PREPIASTER / FENCE/ ALARMS
#57 GUNITE
BLDG-FINAL
Allow 48 hours
Allow 48 hours
call before 2 pm
#35 PHOTO VOLTAIC
#38 SIGNS
BLDG-FINAL
CODE# MECHANICAL
#41 UNDERGROUND DUClS & PIPING
#44 0 DUCT & PLENUM 0 REF. PIPING
#43 HEAT-AIR COND. SYSTEMS
UNDERGROUND (11,12,21,31)
#82 DRYWALL,EXT LATH, GAS TES (17,18,23)
#83 ROOFSHEATING, EXTSHFAR(13,15)
#84 FRAME ROUGH COMBO (14,24,34,44)
#85
A/S UNDERGROUND VISUAL
A/S UNDERGROUND HYDRO
A/S UNDERGROUND FLUSH
A/S OVERHFAD VISUAL
A/S OVERHFAD HYDROSTATIC
A/SFINAL
F/AROUGH-IN
F/AFINAL
FIXED EXnNGUISHING SYSTEM ROUGH-IN
FIXED EXnNG SYSTEM HYDROSTATIC TEST
FIXED EXnNGUISHING SYSTEM FINAL
MEDICAL GAS PRESSURE TEST
MEDICAL GAS FINAL
Date
Date
Date
COPY OF CARD
REQUIRED
Ins ector
Ins ector
Ins ector
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnlcal I Environmental & Construction Engineering I Civil Engineering I Surveying
INSPECTION REPORT PAGE 1 OF 1
CTE JOB NO. 10-14654 ------
REPORTNO.
PROJECT NAME Had a Family Farm subdivision INSPECTION MATERIAL IDENTIFICATION
ADDRESS 121835 Buena Vista Way
Carlsbad, ca
ARCHITECT
ENGINEER JD
CONTRACTOR
OTHER
California West
INSPECTION DATE 2SJuly2D19 ------------
PLAN FILE/OTHER
BLDG. PERMIT/OTHER See below ----------
□
li1:I
□
~
□
□
□
□
□
CONCRETE CONC. MIX NO. & lb/in2
REINF. STEEL GROUT MIX NO. & lbnn2
MASONRY MORT AR TYPE & lb/in2
P.T. CONCRETE REINF. STEEL GR/SIZE
FIELD WELDING STRUCTURAL STEEL
SHOP WELDING HIGH-STRENGTH BOLT
BATCH PLANT MASONRY BLOCK
EXP.ANCHOR OTHER
OTHER
MATERIAL SAMPLING
□ CONCRETE □ MORTAR □ GROUT
□ REINFORCING STEEL □ STRUCTURAL STEEL
□ FIREPROOFING □ MASONRY BLOCK
□ BOLTS □ OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION TESTING, OR OTHER PROJECT ISSUES.
Performed final rebar and PT inspection for lots #3, 4. 5 and 6. All rebar checked for size, grade, lap, placement, clearance and coverage.
All PT tendons checked for count, placement and drape. All hold downs placed per plans. All work complies with page PT1 of the
approved plans. All trash and non structural material to be removed from the pour area prior to concrete placement.
Lot. Address
Lot 3 -1765 Yada Pl, Carlsbad, ca.
Lot 4 -1795 Yada Pl, Carlsbad, ca.
Lot 5 -1790 Yada Pl, Carlsbad, ca.
Lot 6 -1760 Yada Pl, Carlsbad, Ca.
Permit#
CBRA2018-0052
CBRA2018-0053
CBRA2018-0054
CBRA2018-0055
Certification of Compliance: All work, unless otherwise noted, compiles with appllcabla codes and the approved plans and specifications.
PRINTED NAME M.G.Sulham
CERTIFICATION NO. 5281716 / sO1026 -------------SIGNATURE~
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
(~~Sr W.0.# 7377-C-SC
-~.J•~j~-MEMO DATE: 07/29/19
NAME: TODD
ct~-.:lv""tll · 0~ -C-llilll • Eu"io'-"a.,..,,uit HOURS: 3.5
CLIENT CAL-WEST TRACT YADA LOCATION CARLSBAD ------------------
SUPER JIM CONTRACTOR GB -------------------------------
GSI ON SITE AT CLIENT'S REQUEST TO OBSERVE FOOTING EXCAVATIONS ON LOTS 3,4,5,6,10. AND 11.
FOOTINGS ARE EXCAVATED INTO SUITABLE BEARING SOIL.
WE OBSERVED SEWER CONNECTION TRENCHES WHERE THEY CROSS THE FOOTING EXCAVATION IN A LOOSE
AND UNCOMPACTED STATE. CONTRACTOR MAY RECTIFY BY:
1. COMPACTING THE SOIL
2. REMOVING LOOSE SOIL AND PLACING ADDITIONAL CONCRETE [ WRAP PIPE TO PREVENT DIRECT CONTACT]
3. IF UNABLE TO PERFORM# 1OR 2
ADD ADDITIONAL REBAR TEN FEET TO
EACH SIDE OF SEWER PIPE.
AREA OF UNCOMPACTED SOIL IN FOOTING EXCAVATION
ON ALL LOTS.
GeoSoils, Inc.
BY: ___ TBG_7/29/20 __ _
PAGE: 1 OF 1
b~A,lnc.
land planning, civil engineering, surveying
July 29, 2019
w.o. 944-1289-600
Mr. Tim Frazee
CITY OF CARLSBAD,
Building Inspection Division
1635 Faraday Avenue
Carlsbad, CA 92008
ROD BRADLEY, Urban Planner
RONALD L. HOLLOWAY, Civil Engineer
RE: BUILDING FORM VERIFICATION FOR LOTS 3, 4, 5, 6, 10 & 11 OF THE
YADA FAMILY FARM SUBDMSION, CT 15-11
Dear Mr. Frazee:
This letter is to attest that BHA, Inc. has staked the locations for the house construction on the
above-mentioned lots. We have checked the locations of the building forms of the proposed
houses and found the horizontal and vertical locations to conform to the grading plans
prepared by our office.
If you have any questions regarding this matter, please contact our office.
Sincerely,
~';W
Ronald L. Holloway
Senior Vice President
RCE29271
. . ;oiisSI~; .. , ,/1 ... ·-,. '1( -~-. -~· · fj . RONALD L. ·._ 1, ·
_ r.,, ;" HOLLOWAY '. ';;, ·. : i '. NO. 29271 : t":l,
* * <l'~Jo CJ\1\\. .. o,~~"< .·
e OF ct.\.'~ . · ... ,·
cc: Jim Hall-California West Communities
K:\Civil 3D\1289\PROD\Survey\P.id•Fonn Certs\forms\CT 15•1 l_Lols 3,4,5,6,10,11 bldgMform•vcrification.wpd
5115 Avenida Encinas, Suite L ° Carlsbad, California 92008-4387 o (760) 931-8700 o FAX (760) 931-7780
GEOSOILS, INC. W.O.: 7377-C-SC ------------GeoteclYlical-Coastal -GaolOQiC -Environmental DATE: 07/09/19 ____ _c_c..;:cc._: ____ _
NAME: TODD ------------HOURS: 2 ------=------
FOOTING TRENCH OBSERVATION SUMMARY
CLIENT NAME: CAL-WEST PROJECT NAME: VADA ------------
LOCATION/TRACT: __________ _:B:.::Uc::E:::N:..:A...:Vl.::S::T.:_A::.AN::..:::D:...V:.:A.::L:=L=EY.::•...:C::..A:...R:=LS.:.B=:A...:D:.:•...:C::..A:=Ll::..F;_. _________ _
UNIT/PHASE/LOTS: ______________ P:..:Hc::A...:S::E:.:2::L:::O:_T:.::S:.:3::.4.::.5=:·cc6•_:_10:.:·...:&:..:1...:1 ____________ _
REFERENCED GEOTECHNICAL REPORT:
OBSERVATION SUMMARY
TG
07/09/19
TG
07/09/19
TG
07/09/19
TG
07/09/19
INITIALS
DATE
INITIALS
DATE
INITIALS
DATE
INITIALS
DATE
A representative of GeoSoils, Inc. observed on site soil and footing conditions. Soil conditions in the trench
are generally free of loose soil and debris, non-yielding and uniform, and plumb; and are in general
conformance with those indicated In the geotechnical report.
A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bearing strata, and are in general conformance with
recommendations of the geotechnlcal report.
A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (If appllcable). The setback was
in general accordance with the recommendations of the geotechnical report.
FOLLOW NOTES BELOW
NOTES TO SUPERINTENDENT/FOREMAN
1. Footing excavations should be cieaned of loose debris and thoroughly moistened just prior to placing concrete.
2. Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult the
geotechnical report for presoaking recommendations. We note that clayey soils may take an extended period time for
such, and the contractor should schedule accordingly.
3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e. heavy rain, etc.),
we should be contacted to perform additional site observations and/or testing.
4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's design, If
different from the geotechnical report.
NOTES TO BUILDING INSPECTOR
Soil compaction test results, as well as depth of fill, relative compaction, bearing values, corrosivity, and soil expansion index test results are
contained in the As~Graded Geotechnical or Final Compaction Report provided at the completion of grading.
DIGITAL DELIVERY -JIM HALL
Representative of GeoSoils, Inc.
Construction Testing & Engineering, Inc. -----------------
1 n s pection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Swveying
FINAL REPORT FOR SPECIAL INSPECTION & MATERIALS TESTING
December 11, 2019
City Of Carlsbad
Building Inspection Department
1635 Faraday Avenue
Carlsbad, CA 92009
CTE Project No. I O-l 5086T
SUBJECT: SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL
INSPECTION PERFORMED UNDER PERMIT NUMBER:
Lot 3 -1765 Yada Pl,
Lot 4 -1795 Yada Pl
Lot 5 -1790 Yada Pl
Lot 6 -1760 Yada Pl
Lot 10-1737 Buena Vista Wy
Lot 11-1745 Buena Vista Wy
Permit# CBRA2018-0052
Permit# CBRA2018-0053
Permit# CBRA2018-0054
Permit# CBRA2018-0055
Permit# CBRA2018-0058
Permit# CBRA2018-0059
PROJECT ADDRESS: 1835 Buena Vista Way, Carlsbad, California (Phase 2)
I declare under penalty of perjury that, to the best of my knowledge, all of the work
requiring special inspection and materials testing of post•tension reinforcing, post~tension
concrete, reinforcing steel, shear panel framing inspection, concrete, and post stressing
operations has been completed. The inspected work for the structure constructed under
the subject permit is in conformance with the approved plans, the inspection and
observation program and other construction documents, and the applicable workmanship
provisions of the applicable building code. Executed on this eleventh day of December
2019.
TESTING LABO RA TORY OR SPECIAL INSPECTION AGENCY:
CONSTRUCTION TESTING & ENGINEERING, INC.
1441 MONTIEL ROAD SUITE 115
ESCONDIDO, CA 92026
RESPONSIBLE MANAGING ENGINEER OF THE TESTING LABORATORY OR
SPECIAL INSPECTION AGENCY:
Daniel T. Math
State of California Registration Number: 61013
Expiration Date: 12/31/20
SIGNATURE: _ __:~:_-----_ __,,-e:;=7=------
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 www.cte-inc.net
Construction Testing & Engineering, Inc.
Inspection I Testing I Geoleclmical I Envuonmental & Conslrucllon Englneenng I Civil Englnee1irlg I Surveying
INSPECTION REPORT PAGE _1 __ OF _1_
CTE JOB NO. 10-15086T
REPORT NO.
PROJECT NAME Yada Farm phSS!! II
ADDRESS 1765/1795/1790/1760 Yada Pl Carlsbad Ca
Lot 3, 4, 5, 6
INSPECTION
0 CONCRETE
0 REINF. STEEL
0 MASONRY
MATERIAL IDENTIFICATION
CONC. MIX NO. & lb/in'
GROUT MIX 1110. & lb/in2
ARCHITECT MORTAR TYPE & lb/in2
ENGINEER Mark W Swanson 0 P.T. CONCRETE REINF. STEEL GRJSIZE ------
CONTRACTOR □ FIELD WELDING STRUCTURAL STEEL
OTHER 0 SHOPWELOING HIGH0 STRENGTHBOLT _____ _
INSPECTION DATE 9-27-19 -----------0 BATCH PLANT MASONRY BLOCK
PLAN F!L~OTHER CBRJ\2018-00520052/0053 EXP.ANCHOR OTHER
BLDG, PERMIT/OTHER .CBRA2018-005410055 OTHER shear panel framing inspection
MATERIAL SAMPLING
0 CONCRETE O MORTAR O GROUT 0 FIREPROOFING O MASONRY BLOCK
0 REINFORCING STEEL O STFWCTURAL STEEL 0 BOLTS O OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING OR OTHER PROJECT ISSUES.
PerfOrmed a special inspection for the shear walls on l<>t #3 plan 3B per sheets S3.1, S3.2, lot #4 plan 2C per sheets 82.2, S2.3, lot #5
plan 2BR per sheets S2.1, S2.3, lot 6 plan 3CR per sheets S3.1, S3.3 and the shear-Wall sclled~le on sheet S4. Velified correct materials,
nail spec;ing, hold downs, anchor b_olts, drag struts, strapping and sheer ti,,nefer between walls/floor/roof.
Corrections needed:
1. Lot #4 missing anchor bolt at the suite #6 shear-wan.
2. lot #5 missing shear transfer clips at the bedroom #2 shear-wall #6,
3. Lot #5 tlghten boll on 2 hold downs ,;it the Flex room #6 shear-Wall.
4. Loi #6 nail top plate at #6 shear wall at bedroom 116. ·
Cartfflcatlon of Compliance: All work, unless olherwlse notsd, compUn with applicable codes and tho apProved
PRINTED NAME Bill Atwood
CERTIFICATION NO. ICC 5012754 ------------
1441 Montie1Road,Sulte115 I Escondldo,CA92026 I Ph{760)746-4955 I Fax(760)746-9806 I www.cte--inc.net
Construction Testing & Engineering, Inc.
Inspection I Testing I Geoteohnical I Environmental & Conslruclion Engineering I CMI Engineering I Surveying
FINAL REPORT FOR SPECIAL INSPECTION & MATERIALS TESTING
December 11, 2019
City Of Carlsbad
Building Inspection Department
1635 Faraday Avenue
Carlsbad, CA 92009
CTEProjectNo. 10-15086T
SUBJECT; SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL
INSPECTION PERFORMED UNDER PERMIT NUMBER:
Lot 3 • 1765 Yada Pl,
Lot 4 • 1795 Yada Pl
Lot 5 • 1790 YadaPl
Lot 6 -1760 YadaPl
Lot 10-1737 Buena Vista Wy
Lot 11-1745 Buena Vista Wy
Permit# CBRA2018-0052
Permit# CBRA2018-0053
Permit# CBRA2018-0054
Permit# CBRA2018-0055
Permit# CBRA2018-0058
Permit# CBRA2018-0059
PROJECT ADDRESS; 1835 Buena Vista Way, Carlsbad, California (Phase 2)
I declare under penalty of perjwy that, to the best of my knowledge, all of the work
requiring special inspection and materials testing of post-tension reinforcing, post-tension
concrete, reinforcing steel, shear panel framing inspection, concrete, and post stressing
operations has been completed. The inspected work for the structure constructed under
the subject permit is in conformance with the approved plans, the inspection and
observation program and other construction documents, and the applicable workmanship
provisions of the applicable building code. Executed on this eleventh day of December
2019.
TESTING LABORATORY OR SPECIAL INSPECTION AGENCY:
CONSTRUCTION TESTING & ENGINEERING, INC.
1441 MONTIEL ROAD SUITE 115
ESCONDIDO, CA 92026
RESPONSIBLE MANAGING ENGINEER OF THE TESTING LABORATORY OR
SPECIAL INSPECTION AGENCY;
Daniel T. Math
State of California Registration Number; 61013
Expiration Date: 12/31/20
SIGNATURE; __ ~--·~/~-----
1441 Montiel Road, Suite 115 I Escondido, CA92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net