Loading...
HomeMy WebLinkAbout1792 FAIRLEAD AVE; ; CB112689; Permit04-30-2012 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB112689 Building Inspection Request Line (760) 602-2725 1792 FAIRLEAD AV CBAD RESDNTL Sub Type: CONDO -»tde2033t2~ Lot#: 12 $137,317.00 Constuction Type;_§A^_^^ Reference f£GTO401QA '3 1 Structure Type: MF5+ 3 Bathrooms: 2 Status: ISSUED Applied: 10/19/2011 Entered By: RMA Plan Approved: 04/30/2012 Issued: 04/30/2012 Inspect Area: Grig PC ^et10053-) VITALIAFLATS/C0ND0-UNm2 3RD FLOOR - BUILDING #9 - UNIT TYPE 0-2,1154 SF, 448 SF ATTACHED GARAGE LOCATED @ REAR OF 1ST FLOOR, 60 SF BALCONY, 25 SF STORAGE AREA Plan Check#: /Applicant: SHEA HOMES INC ATTN: SARAH BECKMAN STE200 9990 MESA RIM RD 92121 858 526-6554 Owner. Building Permit $844.58 Meter Size Addl Building Permit Fee $0.00 Add'l Reel. Water Con. Fee $0.00 Plan Check $591.21 Meter Fee $0.00 Add'l Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $2,545.00 Strong Motion Fee $13.73 PFF (3105540)$2,499.17 Park In Lieu Fee $0.00 PFF (4305540)$0.00 Park Fee $0.00 License Tax (3104193)$0.00 LFM Fee $0.00 License Tax (4304193)$0.00 Bridge Fee $0.00 Traffic Impact Fee (3105M1)$1,872.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOT/\L $150.00 Renewal Fee $0.00 ELECTRIC/U. TOTAL $55.00 Add'l Renewal Fee $0.00 MECHANICAL TOTAL,$63.00 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 PoL Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Sewer Fee $2,743.00 Reel. Water Con. Fee $0.00 Additional Fees $0.00 Green BIdg Stands (SB1473) Fee $4.00 Fire Sprinkler Fees $0.00 Green BIdg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $11,380.69 Total Fees: $11,380.69 Total Payments to Date:$11,380.69 Balance Due:$0.00 Inspect'or: FINAL APPROVAL Date: ^Clearance: NOTICE: Please take NOTICE that approval of your prefect Includes the "Impositlorf of fees, dedicatkxis, reservations, or other exactions hereafter collectivety referred to as "tees/exactions.* You have 90 days from the date this permit was Issued to pretest Imposition of these tees/exactions. If you protest them, you must toUow the protest procedures sd forth In Government Code Section 66020(a), and fie the protest and any other required Infomnatlon wifo the City Manager for processing In accordance with Cartstjad Municipal Code Section 3.32.030. Failure to timely follow that procedure will t)ar any sutjsequent legal action to attack, review, set aside, void, or annul their imposition. You are heretjy FURTHER NOTIRED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity cfianges, nw planning, zoning, grading or other similar application processing or service fees In connection with this prr^ecL NOR DOES IT APPLY to any fees/Bxactfons of which vou have orevtouslvtwen given a NOTICE stmOar to this, or as to which the statute of imitations has oreviousiv otherwise exoired. <4> n C I T Y O F CARLSBAD Building Department INSPECTION RECORD INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB PRIOR TO 4>BVP.M. FOR NEXT „ ORK DAY INSPECTION FOR BUILDING INSPECTION CALL: 760-602-2725 REC CB112689 1792 FAIRLEADAV VITALIA FLATS/CONDO - UNIT 12 3RD FLOOR - BUILDING #9 - UNIT TYPE C-2, 1154 SF, 448 SF ATTACHED GARAGE LOCATED @ REAR OF 181 FLOOR, 60 SF BALCONY, 25 SF STORAGE AREA RESDNTL CONGO Lot#; 12 SHEA HOMES INC ORD COPY APPROVED TO COVER DATE: Type of Inspection Date Inspector Notes BUILDING FOUNDATION h4/.IB&flauco rr REINFORCED STEEL MASONRY -^oaC Pl' ® □ GROUT □ WALL DRAINS Ot.- €3 TILT PANELS POURSTRIPS COLUMN FOOTINGS SUBFRAME □ FLOOR □ CEIUNG ROOF SHEATHING EXT. SHEAR PAN^tp FRAM^<Z'3o - /^fh INSULATION 3 '.3 EXTERIOR LATH w . INTERIOR LATH & DRYWALL u ^-^NAL PLUMBING □ SEWER AND Bl/CO □PI/CO ' od,UNDERGROUND □ WASTE □ WATER TOP OUT □ WASTE □ WATER (1 ^TUB AND SHOWER PAN □ GAS TEST □GAS PIPING. □ WATER HEATER □ SOLAR WATER ,1 FINAL - : ELECTRICAL □ ELECTRIC UNDERGROUND □ UFER ROUGH ELECTRIC WALLS hLROUGH ELECTRIC CEIUNG - □ ELECTRIC SERVICE U TEMPORARY □ BONDING □POOL PHOTOVOLTAIC ■ HNAL MECHANICAL UNDERGROUND DUCTS & PIPING □ DUCT & PLEM. □ REF. PIPING HEAT - AIR COND. SYSTEMS ft . ^NTILATING SYSTEMS <l > . FINAL - CALL FOR FINAL INSPECTIOW WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVED riAl M. I A IFINAL Sljpt When Appropriate Building Dept (Inspections](760] 602-2725 Fire Department (760] ^-4660 Planning Department (760] 602-4602 H • Engineering Dept (inspections] (760] 438-3891 Building Inspectors (7am-4pni](760] 602-2700 CMWD (760] 438-2722 Ext 7151 FtEV 8/2009- 1635 Faraday Ave. ♦ Carlsbad, CA 92008 ♦ 760-602-2700 * www.carlsbadca.gov SEE BACK FOR SPECIAL NOTES Inspection List Permit#: CB112689 Type: RESDNTL CONDO ^Je Inspection Item Inspector ^t 11/30/2012 301 Overhead Hydro gr AP 11/30/2012 308 Final gr AP 11/30/2012 89 Final Combo PB AP 11/29/2012 89 Final Combo PB NR 11/29/2012 89 Final Combo - Rl 11/27/2012 29 Final Plumbing PB AP 10/23/2012 39 Final Electrical PB AP 09/28/2012 17 Interior Lath/Drywall PB AP 09/24/2012 17 Interior Lath/Drywall PB CA 09/21/2012 17 Interior Lath/Drywall PB AP 09/20/2012 17 Interior Lath/Drywall PB NR 09/10/2012 18 Exterior Lath/Drywall PB AP 09/05/2012 17 Interior Lath/Drywall PB AP 08/31/2012 16 Insulation PB AP 08/31/2012 16 Insulation PB AP 08/30/2012 84 Rough Combo PB AP 08/29/2012 14 Frame/Steel/Boltlng/Weldin PB CA 08/29/2012 14 Frame/Steel/Boltlng/Weidin PB CA 08/26/2012 303 Overhead Visual gr AP n 08/02/2012 16 Insulation PB PA 08/01/2012 13 Shear Panels/HD's PB AP 07/27/2012 22 Sewer/Water Sendee PB WC 07/27/2012 24 RougtVTopout PB NR 07/26/2012 13 Shear Panels/HD's PB PA 07/18/2012 15 Roof/Reroof PB AP 07/11/2012 13 Shear Panels/HD's PB . CO 07/09/2012 11 Ftg/Foundatlon/Piers PB AP 06/29/2012 17 Interior Lath/Drywall PB PA 06/12/2012 13 Shear Panels/HD's PB NR 05/29/2012 11 ' Ftg/Foundatlon/Plers MC AP 05/22/2012 21 Underground/Under Floor PB AP 05/21/2012 21 Underground/Under Roor PB NR VITAUA FLATS/CONDO - UNIT 12 3RD FLOOR - BUILDING #9 - UNIT TYPE C Comments RECEIVED SOILS, PT AND FORM CERT. Monday, December 03,2012 Page 1 of 1 CiA-Ut 17. - Ftoov CITY OF CARLSBAD CIRCUIT CARD B-36 '1 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.cartsbadca.gov Addr^; Ave-Pem^ Number Ownen S|Ai€A.Phone:Area In Sq. Fl / / ^'■j-Co"tnacton 3c.^1\{\4 poveyli^S7?-45c5C> LOCATION CKT BKR SIZE WlFtE,'MtSp.-nr-"REC REC LTG wsc vmE ^ BKR SEE CKT LOCATIONSIZE'TYPE SIZE TYPE rAJJ 1 (5 m CJ 7.1 /V : CU l5.2 fAU 3 \5 \H . cw I CU • )S 4 fltti-fcajjC tl»p AfC 5 25 10 CU (1 /Y CV \S -6 kIC 7 75 (6 CO 7."2./V CV 15 8 oVEP 9 .T-O 17-CU 1 3 5 /3 Vj 15 AT<-1 10 ovep 11 70 CU It 7 tM CV iS AKl 12 7/3 PIVR 13 SO to CV 1 1 5 8 IH CJU 15 AFlI 14 OT-VR 15 SO \6 CU 8 2-')«f CU \5 A?tl 16 17 1 \z CU OOATU 18 19 ""1 17-Co ZJC ,20 21 2 17-CU 20 22 AT'V 23 3 \7 CU 2£>'24 25 3 a CU Zc?26 . Gf} 27 28 29 1 .30 31 32 33 34 35 36 37 -38 39 " 1 40 41 42 B 100 /1A4P BRKFU^ □ MLO AMP MAfft: BUS:, Sen<c» wUaics or ftadT cooductofKA)Sfze;No.__2L__ B)Typ«; □ CU HaLC)tnsula8on; PjComktftSlze: ?.*Swvice jpowxWxmd:A) Size; No. __Jf_C) Otamp locafioni^ ^UFER □ Water Hps C Ground Rod □ B)Ty^: 81 CU Dal 250 - 60(c), 230-104' 250 - 62 Computed lx«d; See Cakxdetion Wcri<s}»et on backBranch ckcuasreqiABd: ''A) Ughfbig Cfttxfte 220 - 3(bX4(d)B) TtMo Snail AppHsnce Clrcufe 210-11(o)0) Laumfry Cfrodf 220-16^) D) Gertral Hea&ig Equipnwnt -422 -12E)Ba«*w)m 210-52(d) • Remarks: C "Tfflfe Z*/ Ajyps ca=a locBlions 210 - 8. 680 - TO; BJ BafiiroonKs)ijQarage(8) S Outdoore AFC! Protected Ctrc. 210 -121SBsc&oom(s) IB Kitchen□Hydromassage Tub o_ / cerlijy (fat atf femshaffcjrts have been torgued frj accdrttence v*aft mwwfecft/fertsSnstrvdiNis and theA the work shown on this Omacafiii'r^pr^sentsUmMoaentce ihevmtkperfwrmivid^PfpomA .-1^ Owner Sc4Mfty □ Contractof ^ / ■ B-36 Page 1 of 2 Rev. 03/09 ..V . It SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an atten^ve m^hod, the ST^DARD METHOD found in ARTICLE 220 of the Nadonai Eiactric Code, may be 1. GENERAL LIGHTING LOADS DweUtnq . . J/ SrT^_ appliance Laundry lo^ - 220-10(b) 1500 VA x _sq.fLx3VA = 220-3(a) - 220-16{a) 1600 VA X drcuSs / circuits = VA 3O00 VA iSO-O VA COOKINQ EQUJPME^ LOADS - Nameplate Value Range . VA = C<x)ktop '■ 1 VA = Oven (s) VA = G^end Lightfng Total SOS'L^ VA VA 'VA VA 3. ELECTRIC DRYER 220r18 (NaJneplate. 5000. VA minimum) DiSrer RO'OO VA = 4. FIXED APPLIANCE LOADS 230-30 (fa) (3) Dishwasher = Disposal = Compactor = Water Heatw =HyiJromassageSathtub =Microwave Ch^,= . BuSt-fri Vacuum = - = 5. OPTIONAL SUBTOTAL (Add aH of the above totals) 3COO .. -Cooking Equipment Total 3o<CO Dryer Total VA (Zoo BOO fiOP noo VA VA VA VA VA VA VA^06 _VA ^ Fixed Appliance Total VA -LOTSZ. VA 6. APPLYING DEMAND FACTORS - TABLE 220-30 First 10,000 VAX 100% = Optional Subtotal (from line 5) { Remaining /O^'^ VA x 40%= 7. HEATING OR AC LOAD - TABLE 220-30Larger of the Heating or AC Load = 8. OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7)» 9. MINIMUM SERVICE SEE « Optfonal Loads Total = 240 Volt 10,000 VA >^38/ VA _S2ij2_yA -zoi^} VA Ampere (Please put total on front of card under Computed Load)