HomeMy WebLinkAbout1795 Yada Pl; ; CBRA2018-0053; PermitPermit
Print Date: 01/28/2020
Job Address:
{city of
Carlsbad
Permit No: CBRA2018-0053
Permit Type:
Parcel No:
1795 Vada Pl
BLDG-Associated Permit Resi
1562205700
Work Class:
Lot#:
Single Family Detached
4
Status:
Applied:
Closed -Finaled
03/13/2018
06/27/2019 Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
$484,362.26
1
3.00
VADA FARM
Reference #: DEV020S8
Construction Type: VB
Bathrooms: 3.50
Orig. Plan Check#: PC2017-0048
Plan Check#:
Issued:
Permit
Fina led:
Inspector: PDrei
Final
Inspection: 1/28/2020 2:40:57PM
Description: VADA FARM: PHASE 2 // LOT 4 // PLAN 2C // 3,004 SF// 174 SF PATIO// 507 SF GARAGE// 49 SF PORCH
Applicant:
MARY NETTLES
5927 Priestly Dr, 110
Carlsbad, CA 92008-8800
760-918-2829
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Owner:
TRUST VADA FAMILY TRUST 03-12-90
1835 Buena Vista Way
CARLSBAD,CA 92008
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PARK IN-LIEU FEES SF DETACHED & DUPLEX: NW
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1 -Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
TRAFFIC IMPACT Residential Single Fam. Outside CFD
WATER METER FEE 1" Displacement (P)
Total Fees: $32,556.32 Total Payments To Date: $32,556.32
Contractor:
CALIFORNIA WEST CONSTRUCTION INC
5927 Priestly Dr, 110
Carlsbad, CA 92008-8800
760-918-6768
Balance Due: $0.00
$1,992.75
$1,394.92
$66.00
$170.00
$92.00
$7,649.00
$182.00
$16,952.68
$20.00
$62.97
$246.00
$56.00
$3,390.00
$282.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
. ·--·---·----------
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0053)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner:
Work Class: Single Family Detached Issue Date: 06/27/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 05/26/2020 Address:
IVR Number: 10089
Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
11/25/2019 11/25/2019 BLDG-17 Interior
Lath/Drywall
111942-2019
Checklist Item
BLDG-Building Deficiency
11/26/2019 11/26/2019 BLDG-17 Interior
Lath/Drywall
112154-2019
Checklist Item
BLDG-Building Deficiency
11/27/2019 11/27/2019 BLDG-17 Interior
Lath/Drywall
112303-2019
Checklist Item
BLDG-Building Deficiency
01/03/2020 01/03/2020 BLDG-Electric
Meter Release
115257-2020
Checklist Item
BLDG-Building Deficiency
BLDG-Gas Meter
Release
115258-2020
01/28/2020 01/28/2020 BLDG-Final
Inspection
January 28, 2020
Checklist Item
BLDG-Building Deficiency
117665-2020
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Rear door
Complete rear door
Cancelled
COMMENTS
Paul Burnette
Except shower/tub areas
Failed Paul Burnette
COMMENTS
Except shower/tub areas
Cancelled Paul Burnette
COMMENTS
Except shower/tub areas
Passed Michael Collins
COMMENTS
EMR emailed to SDGE
Passed Michael Collins
COMMENTS
GMR emailed to SDGE
Passed Michael Collins
COMMENTS
Final inspection by PY on 1 /24/20
TRUST YADA FAMILY TRUST
03-12-90
1795 Yada Pl
Carlsbad, CA 92008
Reinspection Complete
Passed
Yes
Yes
Reinspection Complete
Passed
Yes
Reinspection Complete
Passed
No
Reinspection Complete
Passed
No
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page 3 of 3
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0053)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner:
Work Class: Single Family Detached Issue Date: 06/27/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 05/26/2020 Address:
IVR Number: 10089
Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-27 Shower 108815-2019
Pan/Tubs
Checklist Item
BLDG-Building Deficiency
BLDG-84 Rough 108816-2019
Combo(14,24,34,44)
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
10/29/2019 10/29/2019 BLDG-16 Insulation 109215-2019
Checklist Item
BLDG-Building Deficiency
11/05/2019 11/05/2019 BLDG-17 Interior
Lath/Drywall
109807-2019
Checklist Item
BLDG-Building Deficiency
BLDG-18 Exterior 109805-2019
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
BLDG-23
Gas/Test/Repairs
109806-2019
Checklist Item
BLDG-Building Deficiency
11/13/2019 11/13/2019 BLDG-18 Exterior 110639-2019
Lath/Drywall
January 28, 2020
COMMENTS
Rough frame
Passed Michael Collins
COMMENTS
Passed Michael Collins
COMMENTS
See card for minor pick up
Passed Michael Collins
COMMENTS
Partial Pass Michael Collins
COMMENTS
Except shower/tub areas
Partial Pass Michael Collins
COMMENTS
Complete rear door
Passed Michael Collins
COMMENTS
Passed Michael Collins
TRUST YADA FAMILY TRUST
03-12-90
1795 Yada Pl
Carlsbad, CA 92008
Reinspection Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Complete
Passed
Yes
Complete
Page 2 of 3
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0053)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner:
Work Class: Single Family Detached Issue Date: 06/27/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 05/26/2020 Address:
IVR Number: 10089
Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
07/03/2019 07/03/2019 BLDG-SW-Pre-Con 096542-2019
Checklist Item
BLDG-Building Deficiency
07/18/2019 07/18/2019 BLDG-21
Underground/Unde
rfloor Plumbing
098013-2019
Checklist Item
BLDG-Building Deficiency
BLDG-22
Sewer/Water
Service
098012-2019
Checklist Item
BLDG-Building Deficiency
07/30/2019 07/30/2019 BLDG-11
Foundatlon/Ftg/Pier
s (Rebar)
099080-2019
Checklist Item
BLDG-Building Deficiency
09/17/2019 09/17/2019 BLDG-15
Roof/ReRoof (Patio)
104404-2019
Checklist Item
BLDG-Building Deficiency
10/01/2019 10/01/2019 BLDG-13 Shear
Panels/HD (ok to
wrap)
105896-2019
Checklist Item
BLDG-Building Deficiency
10/17/2019 10/16/2019 BLDG-13 Shear
Panels/HD (ok to
wrap)
107605-2019
Checklist Item
BLDG-Building Deficiency
10/24/2019 10/24/2019 BLDG-14
Frame/Steel/Boltin
g/Welding (Decks)
January 28, 2020
108448-2019
Passed Michael Collins
COMMENTS
Passed Michael Collins
COMMENTS
Waste to POC
Passed Michael Collins
COMMENTS
Waste to POC
Passed Michael Collins
COMMENTS
Ufer in place.
Partial Pass Michael Collins
COMMENTS
Sheathing nailing only
Partial Pass Michael Collins
COMMENTS
Prelim insulation/shear at exterior siding
locations
Passed Peter Dreibelbis
COMMENTS
Prelim insulation/shear at exterior siding
locations
Passed Michael Collins
TRUST YADA FAMILY TRUST
03-12-90
1795 Yada Pl
Carlsbad, CA 92008
Reinspection Complete
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Complete
Passed
Yes
Complete
Page 1 of 3
~~· ¥ CITY or
CARLSBAD
RECORD COPY 1.r.rr ~ CBRA2018-0053
Building Division INSPECTION RECORD 1795YADA PL
YADA FARM: PHASE 2 // LOT 4 II PLAN 2C // 3.004 SF II
174 SF PATIO// 507 SF GARAGE II 49 SF PORCH
t.'I 1I\ISPECTION RECORD CARD WITH APPROVED
ANS MUST BE KEPT ON THE JOB
~LL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION
0 FOR BUILDING INSPECTION CALL: 760-602-2725
DEV02058
PC2017-0048
1562205700
4/18/2018
OR GO TO: www.CarJsbadca.gov/Bujlding AND CLICK ON'
"Request Inspection" • CBRA2018-0053
DATE:
If "YES'" is checl,ed below that Division's approval is required .Q..!'.ior torgg_y_~$1i_i:a_g a Final Building Inspection. If you have any questions
please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to
760-602-8560, email to Qf~gi1Jsp_~~Ugn~@c,3rlslrn«..G~-ov or bring in a COPY of this card to; 1635 Faraday Ave., Carlsbad.
IF MARKED "YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION
STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours
IF MARKED "YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING
Fire Prevention
Planning/Landscape
CM&I (Engineering Inspections)
MASONRY PRE GROUT
□ GROUT □ WALL ORAINS
~ TILT PANELS
#11 POUR STRIPS
#11 COLUMN FOOTINGS
#14 SUBFRAME O FlOOR O CEILING
#15 ROOF SHEATHING
#13 00, SHEAR PANELS
#16 INSULATION
#18 EXTERIOR LATH
#17 INTERIOR LATlt & DRYWALL
#24 TOP OUT O WASTE O WTR
#27 TUB & SHOWER PAN
#23 □ GAS TEST □ GAS PIPING
#25 WATER HEATER
#28 SOLAR WATER
BLDG-FINAL
CODE# POOLS
#51 POOL EXCAV / STEEL
#52 PLUMBING
#53 ELEC /CONDUIT/WIRING
EQUIPOTENTIAL BOND
':,-." PREPLASTER / FENCE/ ALARMS
#57 GUNITE
BLDG· FINAL
REV 9117
760-602-4660 Allow 48 hours
7 60-944-8463 Allow 48 hours
760-438-3891 Call before 2 pm
#34
#33
#35 PHOTO VOLTAIC
#38 SIGNS
#82 DRYWALL,OOLATlt, GAS TES (17,18,23)
#83 ROOF SHEATING, 00 SHEAR (13,15)
#84 FRAME ROUGH COMBO (14,24,34,44)
A/S UNDERGROUND FLUSH
A/S OVERHEAD VISUAL
Date Ins ector A/S OVERHEAD HYDROSTATIC
A/SANAL
F/A ROUGH-IN
F/AFINAL
AXED EXTINGUISHING SYSTEM ROUGH-IN
FIXED EXTING SYSTEM HYDROSTATIC TEST
AXED EXTINGUISHING SYSTEM ANAL
MEDICAL GAS PRESSURE TEST
MEDICAL GAS FINAL
Date
Date
COPY OF CARD
REQUIRED
Ins ct:or
Ins ector
Ins ector
SEE BACK FOR SPECIAL NOTES
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Su,veying
FINAL REPORT FOR SPECIAL INSPECTION & MATERIALS TESTING
December 11, 2019
City Of Carlsbad
Building Inspection Department
1635 Faraday A venue
Carlsbad, CA 92009
CTE Project No. 10-15086T
SUBJECT: SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL
INSPECTION PERFORMED UNDER PERMIT NUMBER:
Lot 3 -1765 Yada Pl,
Lot 4-1795 YadaPI
Lot 5 -1790 Yada Pl
Lot 6 -I 760 Yada Pl
Lot IO-1737 Buena Vista Wy
Lot 11-1745 Buena Vista Wy
Permit# CBRA2018-0052
Permit# CBRA2018-0053
Permit# CBRA2018-0054
Permit# CBRA2018-0055
Permit# CBRA2018-0058
Permit# CBRA2018-0059
PROJECT ADDRESS: 1835 Buena Vista Way, Carlsbad, California (Phase 2)
I declare under penalty of perjury that, to the best of my knowledge, all of the work
requiring special inspection and materials testing of post-tension reinforcing, post-tension
concrete, reinforcing steel, shear panel framing inspection, concrete, and post stressing
operations has been completed. The inspected work for the structure constructed under
the subject permit is in conformance with the approved plans, the inspection and
observation program and other construction documents, and the applicable workmanship
provisions of the applicable building code. Executed on this eleventh day of December
2019.
TESTING LABORATORY OR SPECIAL INSPECTION AGENCY:
CONSTRUCTION TESTING & ENGINEERING, INC.
1441 MONTIEL ROAD SUlTE 115
ESCONDIDO, CA 92026
RESPONSIBLE MANAGING ENGINEER OF THE TESTING LABO RA TORY OR
SPECIAL INSPECTION AGENCY:
Daniel T. Math
State of California Registration Number: 61013
Expiration Date: 12/31/20
SIGNATURE: __ ~--~.,e:;=~~-----
1441 Montiel Road, Suite 115 Escondido, CA 92026 Ph (760) 7464955 I Fax (760) 746-9806 I www.cte-lnc.net
GEOSOILS, INC. W.O.: 7377-C-SC -------------Geotechnical-Coastal -Geologic -Environmental DATE: 07/09/19 -----=---'-'------NAME: TODD -------------HOURS: 2 -------------
FOOTING TRENCH OBSERVATION SUMMARY
CLIENT NAME: CAL-WEST PROJECT NAME: VADA -------'---''-'-'------
LOCATION/TRACT: BUENA VISTA AND VALLEY. CARLSBAD. CALIF. ______________ .;_ __ .:;;_.c__:=___;_;__ __ ---'----____________ _
UNIT/PHASE/LOTS: PHASE 2 LOTS 3,4,5,6, 10, & 11 ______________ ...::....::.::...=-=.:...:..::...::.:=c:;__---'-------------------
R E FERENCE D GEOTECHNICAL REPORT:
OBSERVATION SUMMARY
TG
07/09/19
TG
07109/19
TG
07/09/19
TG
07/09/19
INITIALS
DATE
INITIALS
DATE
INITIALS
DATE
INITIALS
DATE
A representative of GeoSolls, Inc. observed on site soil and footing conditions. Soil conditions in the trench
are generally free of loose soil and debris, non-yielding and uniform, and plumb; and are in general
conformance with those indicated in the geotechnical report.
A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bearing strata, and are in general conformance with
recommendations of the geotechnical report.
A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (If applicable). The setback was
in general accordance with the recommendations of the geotechnical report.
FOLLOW NOTES BELOW
NOTES TO SUPERINTENDENT/FOREMAN
1. Footing excavations shoukt be cleaned of loose debris and thoroughly moistened just prior to placing concrete.
2. Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult the
geotechnical report for presoaklng recommendations. We note that clayey soils may take an extended period time for
such, and the contractor should schedule accordingly.
3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e. heavy rain, etc.),
we should be contacted to perform additional site observations and/or testing.
4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's design, if
different from the geotechnlcal report.
NOTES TO BUILDING INSPECTOR
Soil compaction test results, as well as depth of fill, relative compaction, bearing values, corrosivity, and soil expansion index test results are
contained in the As-Graded Geotechnical or Final Compaction Report provided at the completion of grading.
DIGITAL DELIVERY -JIM HALL
Representative of GeoSoils, Inc.
C) ~ Constructron Testing & Engineering, Inc.
~ • lnspecllon I Testing I <leotechnieal I Enwonmen\31 II Cons!rudlon Engineelfng I Civil Engineelfng I Sun,eying
INSPECTION REPORT
PROJECT NAME Vada Farm phas<1 II
ADDRESS 1765/1795/179011760 Vada Pl Carlsbad Ca
Lot 3, 4, 5, 6
INSPECTION
0 CONCRETE
0 REINF. STEEL
PAGE 1 OF 1 ---
CTE JOB NO. 11l-15086T
REPORT NO.
MATERIAL IDENTIFICATION
CONC. MIX NO. & lblin2
GROUT MIX NO. & lb/in2
ARCHITECT 0 MASONRY MORTAR TYPE & lblin2
ENGINEER Mart< W Swanson 0 P.T.CONCRETE REINF.STEELGR./SIZE _____ _
CONTRACTOR 0 FIELD WELDING . STRUCTURAL STEEL
OTHER 0 SHOP WELDING HIGHa.STRENGTH BOLT
INSPECTION DATE 9-27-19 --'----------0 BATCH PLANT MASONRY BLOCK
PLAN FILE/OTHER CBRA201l!-00520052/0053
BLDG. PERMrr/OTHER CBRA2018-0054/0055
□
Ct]
EXP.ANCHOR OTHER
OTHER shear panel framing inspection
MATERIAL SAMPLING
0 CONCRETE O MORTAR O GROUT □ FIREPROOFING O MASONRY BLOCK
0 REINFORCING STEEL O STRUCTURAL STEEL 0 BOLTS O OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REl'AA.RKS
PLEASE NOTE ANY RE-INSPECTION. TESTING OR OTHER PROJECT ISSUES.
PerfOnned a special ins~on for the shear walls on lot #3 plan 3B per sheets S3.1, 83.2, lot #4 plan 2C per sheets S2.2, S2.3, lot #5
plan 2BR per sheets S2.1, S2.3, lot 6 plan 3CR per sheets S3. 1, S3.3 and the shear-wall schedlile on sheet 84. Verified correct materials,
nail e!)l!c;ing, hold downs, anchor bolts, drag struts, strapp,'ng and ohear transfer between walls/floor/roof.
Corrections needed:
1. Lot #4 missing anchor bolt at the suite #6 shear-wall.
2. lot #5 missing shear transfer clips at the bedroom #2 shear-wall #6.
3. Lot#5llghten bi:>lton 2 hold downs at the Flex room #6shear-wall.
4. Lot #6 nail top plate al #6 shear wall al bedroom #6. ·
Certification of Compllal!Ce: All work, unleo!! otherwise noted, CQ111plla with appllcehle codes and the approved
PRINTED NAME Bill Atwood ==--'-""=-----------
CERT IF IC AT 1O N NO. ICC5012754 ------------
1441 Montiel Road, Suite 115 I Escondido, CA92026 I Ph (760) 746-4955 f Fax(760) 746-9806 I www.cte-inc.net
Construction Testing & Engineering, Inc.
Inspection I Testing I Geoteclmical I Environmental & Construction Engineering I CMI Engineering I Surveying
FINAL REPORT FOR SPECIAL INSPECTION & MATERIALS TESTING
December 11, 2019
City Of Carlsbad
Building Inspection Department
1635 Faraday Avenue
Carlsbad, CA 92009
CTEProjectNo.10-15086T
SUBJECT: SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL
INSPECTION PERFORMED UNDER PERMIT NUMBER:
Lot 3 -1765 YadaPI,
Lot 4 -1795 Yada Pl
Lot 5 -1790 YadaPl
Lot 6 -1760 Yada Pl
Lot 10-1737 Buena Vista Wy
Lot 11-1745 Buena Vista Wy
Permit# CBRA2018-0052
Permit # CBRA20 I 8-0053
Permit # CBRA2018-0054
Permit# CBRA2018-0055
Permit# CBRA2018-0058
Permit# CBRA2018-0059
PROJECT ADDRESS: 1835 Buena Vista Way, Carlsbad, California (Phase 2)
I declare under penalty of perjwy that, to the best of my knowledge, all of the work
requiring special inspection and materials testing of post-tension reinforcing, post-tension
concrete, reinforcing steel, shear panel :framing inspection, concrete, and post stressing
operations has been completed. The inspected work for the structure constructed under
the subject permit is in conformance with the approved plans, the inspection and
observation program and other construction documents, and the applicable workmanship
provisions of the applicable building code. Executed on this eleventh day of December
2019.
TESTING LABORATORY OR SPECIAL INSPECTION AGENCY:
CONSTRUCTION TESTING & ENGINEERING, INC.
1441 MONTIEL ROAD SUITE 115
ESCONDIDO, CA 92026
RESPONSIBLE MANAGING ENGINEER OF THE TESTING LABORATORY OR
SPECIAL INSPECTION AGENCY:
Daniel T. Math
State of California Registration Number: 61013
Expiration Date: 12/31/20
SIGNATURE:._----=~=----·_.,,,.,:a-/=----~
1441 Montie1Road,Suite115 I Escondido,CA92026 I Ph(760)746-4955 I Fax(760)746-9806 I www.cte-inc.net
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical I Environmental & Construciion Engineering I CivH Engineering I Surveying
INSPECTION REPORT PAGE 1 OF 1 ---
CTE JOB NO. 10-14654 ------
REPORTNO.
PROJECT NAME Had a Family Farm subdivision INSPECTION MATERIAL IDENTIFICATION
ADDRESS 121835 Buena Vista Way
Carlsbad, ca
ARCHITECT
ENGINEER JD
CONTRACTOR
OTHER
California West
INSPECTION DATE 29July2019 ------------
PLAN FILE/OTHER
BLDG. PERMIT/OTHER See below ----------
□
~
□
i2I
□
□
□
□
□
CONCRETE CONC. MIX NO. & lb/in2
REINF. STEEL GROUT MIX NO. & lbnn2
MASONRY MORT AR TYPE & lb/in2
P.T. CONCRETE REINF. STEEL GR/SIZE
FIELD WELDING STRUCTURAL STEEL
SHOP WELDING HIGH-STRENGTH BOLT
BATCH PLANT MASONRY BLOCK
EXP.ANCHOR OTHER
OTHER
MATERIAL SAMPLING
□ CONCRETE □ MORTAR □ GROUT
□ REINFORCING STEEL □ STRUCTURAL STEEL
□ FIREPROOFING □ MASONRY BLOCK
□ BOLTS □ OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION TESTING OR OTHER PROJECT ISSUES.
Performed final rebar and PT inspection for lots #3, 4, 5 and 6. All rebar checked for size, grade, lap, placement, clearance and coverage.
All PT tendons checked for count, placement and drape. All hold downs placed per plans. All work complies with page PT1 of the
approved plans. All trash and non structural material to be removed from the pour area prior to concrete placement.
Lot. Address
Lot 3 -1765 Yada Pl, Carlsbad, ca.
Lot 4 -1795 Yada Pl, Carlsbad, ca.
Lot 5 -1790 Yada Pl, Carlsbad, ca.
Lot 6 -1760 Yada Pl, Carlsbad, Ca.
Permit#
CBRA2018-0052
CBRA2018-0053
CBRA2018-0054
CBRA2018-0055
Certification of Compliance: All work, unless otherwise noted, compiles with applicable codes and the approved plans and specifications.
PRINTED NAME M.G.Sulham
CERTIFICATION NO. 5281716/SD1026 -------------SIGNATURE~
1441 Montiel Road, Suite 115 I Escondido, CA92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
~~•~bc_,j u~. W.0.# 7377-C-SC
MEMO DATE: 07/29/19
/ '-__,) L4, NAME: TODD ·--------Cleulfl:lw'""'al · ~ .. 0-.W ~ EM•iir'-"•-IMI HOURS: 3.5
CLIENT CAL-WEST TRACT YADA LOCATION CARLSBAD -----------------
SUPER JIM CONTRACTOR GB -------------------------------
GSI ON SITE AT CLIENT'S REQUEST TO OBSERVE FOOTING EXCAVATIONS ON LOTS 3,4,5,6,10. AND 11 .
FOOTINGS ARE EXCAVATED INTO SUITABLE BEARING SOIL
WE OBSERVED SEWER CONNECTION TRENCHES WHERE THEY CROSS THE FOOTING EXCAVATION IN A LOOSE
AND UNCOMPACTED STATE. CONTRACTOR MAY RECTIFY BY:
1. COMPACTING THE SOIL
2. REMOVING LOOSE SOIL AND PLACING ADDITIONAL CONCRETE [ WRAP PIPE TO PREVENT DIRECT CONTACT]
3. IF UNABLE TO PERFORM# 1OR 2
ADD ADDITIONAL REBAR TEN FEET TO
EACH SIDE OF SEWER PIPE.
AREA OF UNCOMPACTED SOIL IN FOOTING EXCAVATION
ON ALL LOTS.
GeoSoils, Inc.
BY: ___ TBG_7/29/20 __ _
PAGE: 1 OF 1
b~A,lnc.
land planning, civil engineering, surveying
July 29, 2019
w.o. 944-1289-600
Mr. Tim Frazee
CITY OF CARLSBAD,
Building Inspection Division
1635 Faraday Avenue
Carlsbad, CA 92008
ROD BRADLEY, Urban Planner
RONALD L. HOLLOWAY, Civil Engineer
RE: BUILDING FORM VERIFICATION FOR LOTS 3, 4, 5, 6, 10 & 11 OF THE
YADA FAMILY FARM SUBDIVISION, CT 15-11
Dear Mr. Frazee:
This letter is to attest that BHA, Inc. has staked the locations for the house construction on the
above-mentioned lots. We have checked the locations of the building forms of the proposed
houses and found the horizontal and vertical locations to conform to the grading plans
prepared by our office.
If you have any questions regarding this matter, please contact our office.
Sincerely,
~';W
Ronald L. Holloway
Senior Vice President
RCE29271
. ;oiiss1~; .. ... ~ '? .. ······-. 'I( ·.
/~' .. ~-' . · {j : RONALD L. '{:, ·
. [!: 1• HOLLOWAY '. 'i, :
· i;J : NO. 29271 ·.: ~ ,
~' ·;:;, * * tl'i '"'" .' ~;, C/\1\\. . "q,~, ,
e OF c~"'~ . ·
cc: Jim Hall-California West Communities
K:\Civ:il 3D\1289\PROD\Survey\Pad-Form Certs\forms\CT 15-1 l_Lots 3,4,5,6,10,11 bldg-rorm-vcriftcatlon.wpd
5115Avenida Encinas, Suite L o Carlsbad, California 92008-4387 o (760) 931-8700 o FAX (760) 931-7780