Loading...
HomeMy WebLinkAbout1808 OAK AVE; ; 86-514; Permit4 7 ¶ hereby affirm that I have a certificate of consent lob sell-insure, or a certificate of Workers Compensation fo-' surance. or a certified copy thereof (Sec. 3800. Labor Code)1 POLICYNO - COMANY,. '"Copy is wi filed with the city,, ,. 0 Certified : she eby fun shed 0 . . - CERTIFICATE OF EXEMPTION FR( M. C) - - WORKERS' COMPENSATION INSURANCE a U) (This section need not be completed if the permit is for one hundred dollars (9100) or less)LLI ,.. 0 I certify, that in the'performance 01 the work for which . this permit is issued. I shall not employ any person inapy ',manner so as to become subject to the Workers' Compen-'' '5 saliOn Laws of California. NOTICE TO APPLICANT: It, alter' r,rakisg this ertiIlcate - of Exemption. you should become subject 10 the Workers-,.l Compensation pronislons 01 the LaboçCode."you most ' fprlhwlth Comply with such provisions or this permit shalt be deemed revoked, ' 0 * ['0I;hereby'afIlrm that ,there is construction lending IZ agency for the performance of the work for which this per. LAJ - oj ,mit is Issued (Sec., 3097. Civil Code) .. . - Lu Lender's Name I. L Lender's Address - '5 .5—.- ,-' 4 APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.' t_ -r •- 'CARLSBAD BUILDING DEPARTMENT . - 'APPLICATION & PERMIT ' - ' - 2075 Las Palmas Dr. Carlsbad, CA 92009-4859 (619) 438-1161 . '. .. , ' -- - , . - . - -. __•._ _,• JOB ADDRESS AV. ST. NEAREST CROSS ST. DATE OF APPLICATION Jc'OAK ,'-AVE_________ BUSINESS LICENSE # '3e-oqc VALUATION PERMIT NUMBER '. CONTRACTORS PHONE N -' - ZONE ASSES7N OW_E CONTRACTOR,/ I 4 OWNELSN OT NTRACTOR'SAOO ~ ~Aer,414 STATE LICENSE Z f 4 , YL 9/ '0 7L -. iL pAGE 84( OWNENSMA 0-0~ NGAODR .30 DESIGNER DESIGNERS PHONE '• 1PTION L C.Mt _______cr'"- OF WORK DESIGNER'S ADDRESS 25731 STATE LICENSE NO. ~ .1 _4_- NO _4vt~~, P FLRV bMI --331. OCCGP EDU STORIES vDD, PARKING SPACE RES UNITS GRADING PERMIT ISSUED REDEVELOPMENT - ' ' • TYPE - 0CC LOAD FIRE SPR '' 1 - • . - - - ' - - ' AREA • CONST oD_N 0 __'vDND _" ' - . YO. _ND ,otyaIi Unless Machine Certified, QTY $ PLUMBING PERMIT ISSUE QTY'.L MECHANICAL PERMIT ISSUE 3 - SUMMARY/ACCOUNT NUMBER EACH.FIXTUAEJRAP. • '7?7 INSTALL FURN. DUCTS UP TO 100,000 BTU - , BUILDING PERMIT • 001'81O0O;00'8220 - J - : ' -"Law). , ' .-' e ç - . ' S - OVER 100,000 6TU ' SIGN PERMIT - - 001-810-00-00-8221 - 4 - 4 iog conditions exist:.' 'EACH WATER HEATER AND/OR VENT . . 5 BOILER/COMPRESSOR UP TO 3 HP . . - PLCHECK - - - 001-81000-00-8821 W $ ' 2. I have lived in my 'home for twelve months -- EACH GAS SYSTEM 1 104 OUTLETS 4, ' BOILER/COMPRESSOR 3.15 HP T5L PLUMBING - 1-810-00-00-8222 • ' EACH GASSYSTEM 5 OR MORE - ' - ' . - .' METL FIREPLACE - . . S. ' - 00 gz 4 LECTRICAL 001810-00-008223 - . 0 lam exempt under Sec.-'' - . EACH INSTAL., ALTER, REPAIR WATER PIPE - ' . • - VENT FAN SINGLE DUCT ,' ' - !.MECHANICAL - 001810:00.008224 EACH VACUUM BREAKER -• • * . MECH EXHAUST - HOOD/DUCTS y - MOBILEHOME 001-81000-00-8225 WATER SOFTNER . - - - - . - ' RECOCATION OF LA FURNACE/HEATER - ' ' - SD SOLAR 001-810-00-00-8226 -- -. EACH ROOF DRAIN(INSIDE) . -' , - , - . - , . DRYER VENT . :__-Z:zj ' ' 'STRONG MOTION 880-519-92-33 - - - ii TOTAL MECHANICAL -Z - FIRE SPRINKLERS 00-810-00-00-8227 PUBLIC FACILITIES FEE 32081000008740 ,' BRIDGE FEE - 360810-00008740 . 'QTY, - ELECTRICAL PERMIT: ISSUE ' - - . • - -. ' ' - ' a QTY. MOBILE HOME SETUP': . ' - . - • '" • PARK-IN-LIEU (AREA I NEW CONST EA AMP/SWT1I3KR '- - - .. CAR PORT - , ' - - ' 4'- - TIF -' . 13481000-00-8835 - - • - 3 PH - , -, - AWNING . - , LA COSTA TIF - 133-810-00-00-8835 'EXIST BLDG'EA AMP/SWT/BKR • ,, , . - GARAGE - ' . - C ' ' FMF 1 PH 3 P ''' . " 4 ........ . ' ' - . LICENSE TAX -. - 001-810-00-00-8162 - REMODEL.'ALTR' PER CIRCUIT - -- /8 - - . - ' - ' . MFF - - ' 880-519-92-57 TEMP POLE 200AMPS! OVE.R200,,IPI,. - ' . . ' . • . ' ' - -' - '' - ____________ - CREDIT DEPOSIT -- - - TOTAL ELECTRICAL - - ' -'I -' ..TOTAL L FEES PAYABLE .,,[ -• I HAVE REFULLY EXA fNEDTHE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY Eepirabron.EverypermitinsuedbyfheBuiIdingOifrcielunderfheprovusionoofs * AN OSHA PSRM1T ISREOUIRE0 FOR EXCAVATIONS OVER Code shall expire by limitation and become null and void It e' 2Y...OFL CERTIFY Ut.DERu PERJURY-THAT ALL INFORMATION HEREON INCLUDING THE authorized menced within 180 days :he DECLARATIdT TRU AFTir CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS building O wor rom - 50" the date of STUCT1JRES DEEP AND DEMOLITION OR CONSTRUCTION OF OVER 3 STORIES IN HEIGHT - permit, or if thebuilding or work authorized by such ISSUED: TO COMPLY WI1H'ALL CITY,-COUN'IY AND STATE LAWS GOVERNING BUILDING CON- abandoned at any time after the work is commenced for a period suspended Or 01180 days. STRUCTION, WHETHER S'ECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND , - KEEP HARMLESS THE CItY OF CARLSBAO'AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND APPLICANT 's SIGNATURE OWNER APPROV CONTRACTOR By, TI -- - •, DATJ/ - IG" — 1C ux BY PHONED EXPENSES WHICH ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE,OF THE I IT GRANTING OF THIS PE4 N , Ivor BALL POINT PEN ONLY & PRESS HARD-- 7 3 I hereby affirm that I am licensed under I - u.I.'lProvlalóna of Chapter 9 (commencing with I Section 7000) of Division 3 ot:the Business ,—'I'' and Professions Code, and my license is in Z L- full force and effect. 3' I hereby affirm that I 'am exempt from the Contrac' - tors License 'law for the following reason (Sec. 703t .5 - :-: Business and Professions Code: Any city or county which Is quires a permit to construct, alter, improve, demolish. or * ) repair any structure, prior to its issuance also requires the ap phcant for such permit to tile a signed statement that he is licensed pursuant to the provisions 01 the Contractor's License LAW (Chapter 9 commencing with Section 7000 01 - -. Division 301 the Business and ProlessionsCode) or that is en' empt therefrom and the basis or the alleged exemption. Any I - violation 01. Section 7031:5 by an applicant for a permit sub- ..,: jects the applicant to a civil penalty 01 not more than live hun, dred dollars ($500). I I,as owner 01 the property, or my employees with wages as their sole compensation,.,will do the work, and the struc- p o tare is out intended or uttered for sale (Sec. '7044 Business and Professions Code: The Contractor's License Law does 5 not apply to an owner of property who builds or improves I thereon and who does such work himself or through his own I ..'employees, provided that such improvomenls are not intend- 181 - ed or offered for sale. It, however, the building or improve- '? Z ment is sold within one year of completion: the owner-builder 39 will have the burden 01 proving that he did not build or im' 0 irove for the purpose 01 sale). - 0 1,-as owner 01 the property, am exclusively contracting I- with licensAd contractors to construct the project (Sec. 7044, - Business and PrOtessious Code: The Contractor's License - Law does not apply loan owner ol,properby who builds or im- S proves Ihereon, and who contracts for each projects with a - p (I) . -• contractor(s) license pursuant In the Contractors License .0 As a homeàwoor I am'improvin'g my home. And the 10110w' ) ._ .1., The work is being performed prior to sale. - a prior 10 completion 01 this work.-.'' 181 3. I have 001 claimed this exemption during the 0 . , - last three years. . - for this reason TYPE - DATE INSPECTOR BUILDING FOUNDATION REINFORCED STEEL MASONRY GUNITE OR GROUT SUB FRAME LI FLOOR Li CEL-UN SHEATHING Li ROOF EAR FRAME .fr. EXTERIOR LATH INSULATION INTERIOR LATH & DRYWALL PLUMBING Li SEWER AND BL/CO "L/CO 4) UNDERGROUND 0 WASTE U WATER TOP OUT 0 WASTE DNATER TUB AND SHOWER PAN GAS TEST Li WATER HEATER 0 SOLAR ATER ELECTRICAL 1 Li ELECTRIC UNDERGROUND 1l UFFER ROUGH ELECTRIC i /-')i' -7t---. 0 ELECTRIC SERVICE Li TEMRORARY 0 Li BONDING 0 POOL MECHANICAL I Li DUCT & PLEM., Li REF. PIOING HEAT - AIR COND. SYSTEMS .. 4. VENTILATING SYSTEMS ... * 0 - CALL FOR FINAL INSPECTION WHEN .ALL APRROP.?IAJ-E ITFM ARflVF I-IAJVF RFN A'PPROVEDt FINAL PLUMBING ' ELECTRICAL _______ . _________ MECHANICAL 0 4 GAS r______ 0 BUILDING LV\ SPECIAL CONDITIONS 4, 0 •,00 .• FIELD INSPECTION RECORD 0 R.gOUIRED SPECIAL INSPECTIONS INSPECTOR'S NOTES .' . INSPECTION REQ. IF INSPECTOR'S DATE 41 CHECKED APPROVAL \0 SOILS COMPLIANCE PRIOR TO - FOUNDATION INSP 0 STRUCTUR.AL CONCRETE OVER 2000 PSI 0 PRESTRESSED CONCRETE POST TENSIONED CONCRETE FIELD WEEDING HIGH STR'NGTTi BOLTS SPECIAL MASONRY . '. -. PILES CAISSONS . . . 0 0• 0• 0 • :. '0. :j 77 / LI ". ,... City of Carlsbad- 1200 ELM, CARLSBAD, CA 92008 • TEL. (619) 438-5525 MISCELLANEOUS RECEIPT ress /go?('22A' ,4z"P MISCELLANEOUS FEE RECEIPT . PLAN CHECK FEE 001-810-00-00-8821 VALUATION _LJ# . Z.. Owner / . /223- Mailing Address City /afro"zip Contra O1I O/El - El Addrej1 3.AsT . Zi T/j/7El - State Lic. . S Classit. ' City Lic. No. LEGAL DESCRIPTION ASSESSORS PARCEL NO. 2) _ - DESCRIPTION OF WORK Oi El El El PLANIDNO____-ji4 TOTAL _FEE $ CONTACT PERSON' *WARNING: PLAN CHECK FEES. WHERE NO ACTION IS APPLICANT IN 180 DAYS AND NO BUILDING PERMIT-IS - FORFEITED TO THE CITY. COMMENTS:___________________________________________ TAKEN BY THE ISSUED. ARE ADDRESS 53 1 :33/__/j/tj4. /0Y _ PHONE# Siguature of Appiicant/__4'22' —AXe .5 . White - Applicant Yellow - File Pink - (1) Finance (2) Data Process - Gold - Assessor ESGIL CORPORATION :- 9320 'CHESAI'EAKE DR.. SUITE 208 . S SAN DIEGO CA 92123 (619) 560-1468 DATE' U' '. [)APPLICANT IS DI CT JURISDICTION: C -1'2...L,S3)q- CHECKER flFILE COPY PLAN CHECK NO: c — ' • ' , DDE:GNER• PROJECT ADDRESS: PROJECT NAME: C .Ort The plans 'transmitted 'herewith have been corrected where' necessary and substantially comply with the jurisdiction's building codes. The plans transmitted hereth will substantially comply with the jurisdiction's building codes when minor deficien- cies identified S ' are resolved and : checked by building department staff. - The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. V The check list transmitted herewith is'for your-Information. 0 The plans are being held at Esgil Corp until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the •' , - ' S jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to Esgil staff did not advise the applicant contact person that plan check ha been completed. S , - ' • Esgil staff did advise applicant that the plan check has been completed.. Person contacted: LtJS Y1 --hva' ' Date contacted: Telephone #4 S REMARKS: ' , S • ,,, S Co A. )-1q-e'y' r' -' By.: Enclosures _________________ ESGIL CORPORATION • S'. S •• S • . ESGIL CORPORATION 9320 CHESA PEAKE DR., SUITE 208 SAN DIEGO, CA 92123 0 (619)560-1468 . CANT DAPPLI DATE. DIc. JURISDICTION: CITY OF CARLSBAD PLNCHZC1 []FILE COPY PLAN CHECK NO: UPS []DESIGNER PROJECT ADDRESS: \O OPr\. Pri (F PROJECT NAME: : The plans transmitted herewith have been, corrected where necessary and,,substantially comply with the jurisdiction's building codes. • . The plans t'ransmittedherewith will substantially comply b with the jurisdiction's building codes when minor deficien- cies identified . are resolved and checked by building department staff. . The plans transmitted herewith have significant defiiencies L identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted heréith is the jurisdiction's ' '.copy for your information. The plans are being held at 0 Esgil Corp. until corrected plans aresubmitted'.forrecheck. E The applicant's copy of the check list is enclosed for the 0• jurisdiction to return to the applicant contact ,person. The'applicant's copy.of the .check list has been sent to: 14 N D'-t' M Tc q'(Ei iLL— i3 ' Esgil staff did not advise the applicant contact person that plan check has been completed) r# fl+4M 14 tLL'. Esgil staff did advise, applicant that the plan check has been completed. Person.contacted: 0 Date contacted: . • Telephone REMARKS: 0 0 BY:v\A ENCL gz 7 ESGIL CORPORATION 0 • • I' S1) - MM CMM No 14- Date initial plan check completed JURISDIION CITY OF CARLSBAD JJ Sk(Y 1 i\ - Applicant contact person: To CIA WL tY\ Tc LL CJD'I' Telephone: 4 411O 53 PLEASE READ C IZLS f Plan'check is, limited to technical requiements contained in the Uniform 'Building Code, Uniform Plumbing Code, Uniform Mechanical Code, A ' ' National Electrical Code and state laws TELNE No. 1 regulating energy conservation, noise attenuation and access for the handicapped. CLOSlJR: The plan check is based on regulations enforced -i - by the Building Inspection Department. You may have other. corrections based on laws and AA . • ordinances enforced by the Planning Department; Engineering Department or other departments. ()SIB T1 0 Present California law mandates that residential construction comply with Title 24 PJr ADDRESS: - and the following model codes: \ BoB 'Y 1982 UBC (eff. 7/1/85) S 1982 UPC (eff.. 10/1/85) 1984 NEC (eff. 10/1/85) 1982 UMC (eff. 3/1/85) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. PLAN COMMON The circled items need clarification, SIN.E FAMILY AND DUPL19X ThELThGS modification or change. All items have to be . . satisfied before the lans will be in Date plans received by jurisdiction: conformance with the cited codes and -. S I ?,1_\' , regulations. Per Sec. 303(c), 1982 Uniform k - Building Code, the approval of the plans does - not permit the violation of any state, county Date plans received.by Esgil Corporation: orcity law. To speed up the recheck process, note nthis - . list (or a copy) where. each correction item has been addressed i.e. • plan sheets specification. , , . - etc. Be sure to enclose the marked up list . . - when you submit the revised plans. Carlsbad List 10, Single Family Dwelling and Duplex With All Supplements' . . . • -1 -• • - S 5 . S 3/25/86 • • S • • • . '• - •• . . . • • A. PLANS 4an please make all corrections on the original acings and submit two new sets of prints, and y original plan sets that may have been Indicate distance from center line of street or alley to property. line and distance from property lines to proposed building. Section 302 (c). returned to you by the jurisdiction, to: B. FIRE PION Esgil Corporation, 9320 Chesapeake Drive, Walls closer than 3 feet to property lines Suite #208, San Diego, California 92123, shall be one-hour rated construction, have no (619) 5601468. openings, and shall have 30 inch parapets when the building floor area exceeds 1,000 square 2 Please make all corrections on the original feet on any floor. tracings and submit two new sets of prints, and. . (Table 5. A. Section 1709 (a)). any original plan sets that may have been . returned to you by the jurisdiction, to: )(5. Projections, including eaves, may not extend more than 12 inches into the '3 foot The jurisdiction's building department. setback from the property line. Eaves over required windows shall-be not less than 30 3. Indicate on the Title Sheet of the plans, inches from the side and rear property lines. the name of the legal owner and name of person Section 1710 and Section 504 (a) and (b). responsible for the preparation of the plans. Section 302 (a) 7.- . . Plastic skylights shall not be installed 1y1. within 8' of an exterior wall located where 4 -P 'WPons and calculations shall openings in such exterior wall are prohibited or besigned by a California state licensed . required to be protected. engineer or architect. (California Business and Section 5207 (a) 7. Professions Code). Specify on the Title Sheet of the plans the- Projections,.including eaves, shall be /one-hour . fire-resistive construction, heavy gross floor area of each element of this project timber or of noncombustible material if they including dwelling, garage, carport, patio, deck . project into the 3' setback area from the and balcony. Section 302 (c). property line. Section 1710. Provide a statement on the Title Sheet of 13 Show. location of permanently wired smoke the plans that this project shall comply with . detector, centrally located in corridor leading Title 24 and 1982 IJBC, UMC, and UPC and 1984 to sleeping rooms or above stair if sleeping NEC. . . rooms are on upper level. Section 1210. - Submit fully dimensioned plot plan drawn to A smoke detector shall be installed in the scale showing location, size, and use- of all - basement of dwelling units having a stairway existing and proposed structures on the lot. which opens from the basement into the dwelling. Identify property lines and show lot dimensions Such detector shall be connected to a sounding and all easements. Show location of all cut or device or other detector to provide an alarm fill slopes and approximate finish floor which will .be audible in the sleeping area. elevations for all structures and show Section 1210. elevations at all .1ot corners. - - - - Section 302 (c). CLcky2 c 1 - (v ri i'-) 6 L2:Xr ¶2-oc viA S I Io (Q\. L ) O 6\4 L&) - CUM 7 2 . . 3/25/86 - . . C. JX11 SIZ. LI, VENTILATION AND GIAZIM Habitable rooms; other than kitchens, shall (contain at least 70 square feet of floor area. Section 1207 M. 24. Dimension on the plans, the 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 511 (a). - 1 25.. Specify safety glazing for glazing in Window area must be at least 1/10 of the hazardous locations such as glass doors, glazing loor area and a minimum of' 10 square feet per 'adjacent 'to such doors and glazing adjacent to Section 1205 (a). Appears to be -deficient in walking surfaces. Section 5406. 26. Glazing, in the 'same wall plane as a door, must be safety glazing if within 12" of the door and less than 60" above the walking surface, Openable window area inhabitable rooms unless the glazing is leaded on faceted glass. must be 1/20 of the floor area and a minimum of Section 5406 (d) 7. 5 square feet. In bathrooms, laundry rooms and similar rooms 1120 of area is required and 27 Glazing in shower and tub enclosures shall minimum is 1.5 sq. ft. (Section 1205 (a)). be' tempered, laminated or approved plastic At least 1/2 of the common wall must be. '(including windows within 5 feet of tub or , pen and have an opening not less than 25 sq. ft. if light and ventilation' is being. supplied 28 Sleeping rooms shall have a window or from an adjacent room. Section 1205 (a). exterior door for emergency exit. Sill height shall not exceed 441' above the floor. The Required windows shall not open into a window must have an openable area of at least roofed porch unless the ceiling is at least 7 '5.7 square feet with the minimum openable width feet and the longer side is at least 65% open.' 20" and theminimum'openable height 24". Section 1205(a). ' ' Section 1204. Provide mechanical ventilation capable of 'is , A mezzanine an intermediate floor and ZY not providing five air changes per hour in ' , have a floor area exceeding 33 1/3 bathrooms, water closet compartments, laundry percent of the total floor area in the room rooms and similar rooms if required openable ' ' below. The mezzanine floor must have a clear windows are not provided. Section 1205(a). height of 7 feet, above and below, and must have / the long side open to the room below except for I. No habitable room, other than a kitchen, k posts and protective walls or railings not shall be less than 71 01Iin any dimension. . exceeding 42" in height. Section 1716. Section 1207 (c). I ' Show that ceiling height for habitable 'The loft you show does not 'comply as a '4ezzanine floor and is,'by Uniform Building Code rooms is a minimum of 7'611. Section 1207 (a). , definition, a story. Section 1716. Show ceiling height for laundry rooms, . 'hallways, corridors, and bathrooms is a minimum , of 7,0". Section 1207 (a). ( ' :, . '°° ' 0 & JTi'Lôr) tb1,411 VU I VIA U VIA I VO . ' () j (y y\,1' Q vt) c- A-P C ra t.&)I YUOO L< 3 ' 3/25/86 D SIAIAYS AND RAIIJ]S Every stairway landing shall have a measured in the direction of travel, Floors above the second story shall have at least equal to the stairway width 7not less than 2 exits Section 3303 (a)._Section 3306 (g) Required exit doorways shall be not less A door may open over a stairway landing than 36" in width and not less than 6'8" in Oprovided the door, in any position, does not height, and shall be capable of opening at least reduce the clear area of. the landing in the 90 degrees Section 3304 (e) direction of stairway travel, to less than /Porches.' one-half the,required width of the stairway. Provide 36" high protective railing for Section 3306 (g). balconies, and open sides of stair , ,, landings. Openings between railings shall be 74'. A door may open inward at the top step of a less than 6" Section 1711 stairway provided the top step is not more than 7 1/2" lower than the floor level. Show how guardrail connection details are Section 3304 (h). adequate to support 20 pounds per lineal . foot at 4C01yihg a right angle to the top rail. Table 23-B. Provide details of winding stairway with Section 3306 (d) Provide stairway and landing details / XSection 3306 (b) & (c). . . a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 a. Maximum rise 8" and minimum run is - ' inches from where the treads are 5 5 narrowest. b Minimum headroom is 61 6".b Maximum rise is 8 inches C. Minimum width is 3011 . C. Minimum width is 30 inches. 36 fl handrails per Section 3306 (j), shall /.Section Provide spiral stairway details, per satisfy the following 3306 (f) - a. Provide handrail for stairways with 4 - a. Minimum run is 7 1/2 inches measured or more risers at a point 12 inches from where the treads are the narrowest. b Handrail shall be 30 to 34" above the S nosing of treads. - '- S - - b. Maximum rise is 9 1/2 inches. c The handgrip portion of handrail shall c Minimum headroom is 6 feet 6 inches be not less than ,l 1/4" nor more than 2" in cross-sectional dimension Spiral stairways may not be used for - - (See attached). required exits when the area served is greater than 400 sq. ft Section 3306 (f) -- 3/25/86 Spiral stairways must have a clear walking The maximum slope for a fire retardant space of 26 inches betwáen the column and ,4u11t-up roof, with rock or gravel surfacing, is handrail, show dimension. Section 3306 (f). 3 inches in 12 inches, Section 3203(e) 2. Provide I.C.B.0. Research Report and Number ,7<' The minimum slope for afire retardant for metal stairway, or submit plans and built-up roof, with cap sheet surfacing, is 1/2 calculations' and approved fabricator registered inch in -12 inches. Section 3203 ('e) 3. with the building department or note that the / stairway fabrication shall be done under special Specify minimum 1/4 inch per foot roof ,$. inspection per the approved fabrication plans. slope for drainage or design to support Section 306 (a) 4B'and Section 306 (f). accumulated water. Section 3207 (a), Section 7<' In' buildings over 2 stories in height, 2305 (f) and Section .2511 (d) 6 . . provide 3/4 hour fire-rated assemblies for all /Section Show roof drains and overflows. openings - in the exterior wall below or within 10 3207. feet horizontally of an exterior stairway. exit balcony with 2 separated stairways is yt. Provide skylight details to -show compliance exempt. Section 3306 (1). 'with Sections 3401 and 5207 or provide I.C.B.0. . approval number. Exterior stairways shall not project into the 3 foot setback from the property lines. , Plastic skylight must be separated from Section 3306 (n). . . . each other by at least 4 feet. S - Section 5207 (a) 6. I' X The walls and soffits of the enclosed usable space under interior stairs shall be '- Show attic-ventilation. Minimum vent area protected on the enclosed side as required for '",' "is 1/150 of attic area or 1/300 of attic area if one-hour fire-resistive construction. at least 50% of the required vent is at least 3 Section 3306 (m). . . feet above eave vents or cornice vents. Show - required area and area provided. E. OFI? . S Section 3205 (c). Specify roof slope. . ' F. iso - Roof slope is not adequate for 'roof type - specified. Table 32-B; Section 3203 Provide fireplace construction details or (h). note construction to be per attached fireplace standard drawing. Chapter, 37. - . ' Specify roof material and application. - ,$f ' • Show veneer support and connections, in (Seismic • Zones 3 and 4, comply with Section 3002, Chapter 32. - -, • - - 4, 5, 6, and Section 2515 (a) regarding ties and - - • . • '#9 wire in horizontal joints or-show Specify I.C.B.0. or U.L. approval number • • construction to be per attached sheets - for roof materials not covered in U.B.C., e.g.,-.30-1 or 30-2. , title, etc., Section 107. - S • • • " ' Show height and construction details of all /iOpenings between carport and residence "masonry walls chapter 24 require self-closing doors and stationary windows. Section 1214. /6 - , Note that cleanout openings shall be ided at the bottom of all cells to be grout -)( Show garage framing section, size of header filled over 4' in a single pour. Cleanout shall over garage opening, lateral cross bracing at be sealed before grouting, after inspection. plate line, method of bracing garage front, and Section 2414 (a) 8. holddowns if required. chapter 23. Show floor and roof connections to masonry NOTE Maximum shear panel ratio of height to 'walls Connection shall resist 200 pounds per width is 3 1/2 to 1. Table 25-I. lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in Doors may open into the garage only if the wood ledgers is not permitted floor or landing in the garage is not more than Section 2312 (j) 3. A. 1/2" lower than the door threshold. Section 3304(h). Provide details for damp proofing the Xftundation walls, below finish grade, where Provide an 18" raised platform for any FAU, useable space exists on the interior side of the water heater, or other device in the garage, walls Section 1707 (d) which may generate a flame or spark, UMC Section 508, UPC Section 1310 (a). Show a miximum 2" air space and flashing. /between planterand building walls H. FOUNDATION REuwicIS Section 2516 (c) 7 74 Per soils report, note on the plan the G GARAGE AND CARPORTS,jPy / soils classification, whether or not the soil is • expansive, and note the allowable bearing value. 66 Garage requires one-hour fire protection on Section 2905 (c) the garage side of walls and ceiling common to the dwelling Table 5 B Section 503 (d) 7 The foundation plan does not comply with 0. / the soil report recommendation for this project. All elements supporting floor above garage, Please review the report and modify design, including walls supporting floor joists, to have notes and details as required to show one-hour fire-resistive protect-ion on the garage compliance. side Section 503 (a) 68 Show 1 3/8" solid core self-closing door Provide notes on the foundation plan ,P listing the soils report recommendations for for openings between garage and dwelling. • foundations, slab and building pad preparation. Section 503 (d) Garages are not permitted to open into a • -. room used for sleeping purposes Section 1104 P 24ri1 O 4 6 3/25/86 The soils report recommends excavations be Show foundation sills to be pressure reviewed by soils engineer. Note on the treated, or equal. Section 2516 (c) 3. foundation plan that "Prior to the Contractor requesting a Building Department Foundation Show foundation bolt size and spacing. Inspection, the soils engineer shall advise the Section 2907 (e) building official in writing that: ft(. Specify size, I.C.B.0. number and the building pad was prepared in manufacturer of power driven pins. Show edge accordance with the soils. report; and end distance and spacing. Section 306 (f) the utility trenches have been properly backfilled and compacted, 87 If required by structural calculations, and, show size, imbedment and location of hold down anchors on foundation plan Section 2312 (f) the foundation excavations, formings . ,. and reinforcements comply with the . 8 . If hold downs are required by calculations, soils report and approved plan". note on plan that hold down anchors must be tied in place prior to foundation inspection. Show height of all foundation walls. Section .305 (e) 2. "chapter 23. . . Show height of retained earth on all (98.. Show adequate footings under all bearing walls and shear walls. Section 2907 (b). foundation walls chapter 23 96. Show on the elevations, stepped footings 8 If cut or fill slopes exist, show distance "for slopes steeper than-1:10, of foundation to edge of cut or fill slopes and Section 2907 (c) show steepness and heights of cuts and fills j Chapter 29. . . . : p. . Show minimum 18" clearance from .grade to (bottom of floor joists and minimum 12" /1 Note on plans that wood shall be 6" clearance to bottom of girders minimum above finish grade Section 2516 (c) Section 2516 (c) 7. . . .... . . .. . 8 Note Show pier size, spacing and depth into /undistulrbe.d .soil. on plans that surface water will drain Table 29-A away from building and show drainage pattern and key elevations. Section 2905(f).. - . Show minimum underfloor. access of. 1811 x /241-. Section 2516 (c). Dimension foundation per U.B.C. Table 29A: . . . Show minimum underfloor ventilation equal Floors 7to 1 sq. ft. for each 150 sq. ft. of underfloor Supported* Steinwall . Width Depth - area. Openings shall be as closá to corners as 1 . 6" - 12" 12" practicable and shall provide cross ventilation '15" 2 - 8" 18" - on at least two approximately opposite sides. 3 10" 18" 24" Section 2516 (c) *Foundatjons -may sunnort a rônf in a18-It-inn t , 95 Specify that posts embedded in concrete Show. 1/2" minimum clearance between top shall be pressure treated per UBC Std. No. 25- plate of interior partitions and bottom chord of 12-. Section 2516 (c). trusses. (To ensure loading will be as designed). I.FRM4ING Show double top plate with minimum 48" 9 Show wall bracing.- Every exterior wood lap splice. Section 2517 (g) 2. stud wall and main cross partition shall be / braced at each end at least every 25 feet of Show nailing will be in compliance with length with 1 x 4 diagonal let-in braces or "fable 25-Q. equivalent. Section 2517 (g) 3. -. Show or note fire stops at the following X Note cross bridging or blocking. Floor 4ocations per Section 2516 (f): -0sts and rafters 12" or more in depthshall be - supported laterally by bridging at intervals not a. in concealed spaces of stud walls and exceeding 8 feet, unless both edges are held in partitions, including furred spaces, line. Sec. 2506 (g). at the ceiling and floor levels and at 10 foot intervals along the length of X Show blocking at ends and at supports of - the wall. floor,joists, and for rafters at exterior walls Section 2517 (d) 3 b at all interconnections between / concealed vertical and horizontal 4. Show solid blocking at-ridge line and at spaces such as occur at soffits, drop exterior walls on trussed-roofs. .- ceilings and cove ceilings; Section 2506 (g), Section 2517 (h) C. in concealed spaces between stair Show double joists Floor joists shall be stringers at the top and bottom of the doubled under bearing, partitions running: - run and between studs along and in parallel with the joists.,Section 2517 (d) 5 line with the run of stairs if the walls under the stairs are unfinished, Bearing partitions, perpendicular to - - and - joists, shall not be offset from supporting girders, beams, walls or partitions, more than d in openings around vents, pipes, the depth of the joist. Section 2517 (d) 5. - - ducts, chimneys, fireplaces and similar openings which afford a 102 Show rafter -ties. Rafter ties shall be ,,.,.::A - -. passage for fire at ceiling and floor spaced not more than 4 feet on center and be levels, with noncombustible just above the ceiling joists, where rafters and - materials. - - - ceiling -joists are not parallel. - • - - - - - - - Section 2517 (h) 4. - • - • Show stud size and spacing. - Maximum allowable stud heights, Bearing wall 2 x 4 and Show rafter purlin braces to be not less 2 x 6 max. -10'; Nonbearing: -2 x 4 max. 141, 2 than 45 degrees to the horizontal x 6 max 20' Table 25-R-3 Section 2517 (h) 5 - - - - - - - Studs supporting-two floors, a roof and ceiling must be 3 x4 or 2 x 6 at 16" o c - - S - - ' • - Table 25-R-3. - • - - CEMcz -8 - • 3/25/86 ior Note an A I I C Certificate of Compliance 121 Show on the plans all structural glued laminated wood members shall be given requirements developed in the structural to the building inspector prior to erection. calculations. Section 306 (f). Columns and posts located on concrete or Detail all post to beam and post to Q)tinj masonry floors, or decks exposed to the weather connections and reference the detail to Section 2516 or to water splash or in basements and which the plan (m) support permanent structures shall be supported by concrete piers or metal pedestals projecting 112 Detail shear transfer connections, .. above floors unless approved wood of natural including roof and floor diaphragms, to shear resistance to decay or treated wood is used walls Section 2513.Section 2516 (c) 4 a11 Specify nail size and spacing for all ' .. ' pI1dividual concrete or masonry piers shall .,9 shear walls, floor and roof diaphragms project at least 8 inches above exposed ground Indicate required blocking Maintain maximum unless the columns or posts which they support diaphragm dimension ratios. (Tables 25 I, 3, K) are. of approved wood of natural resistance to and Section 4713 d) D0 wood is used S:c026( /to;y Show 3" x .4" or 2" x 6" studs in first of three story building Table 25-R-3 124 Show location of attic access with minimum / size 22" x 30" Section 3205 3/5. . Provide truss'-details and truss ,a1culations for this project. , . Show draft separation for attic areas between units in a duplex Section 2516 (f) 1/6 Provide roof framing plan and floor framing plan. Section 302 (a) 7. : Wood stud bearing walls, with studs at 24" ó.c.,require3ea. 2x40r2ea. 2x60r2 Provide framing sections through ea 3 x.4 top plates if supporting either floor members or roof trusses that are spaced more than 16" p.c. and do not bear within 51.' of the supporting stud. Section 2517 (g) 2. Specify plywood grade and panel Section 320 (a) 7 "identification index Table 25-N Specify all header for 4' sizes opening over When roof pitch is less than 3 12, design 4' wide Section 2517 (g) 5 cidge as a beam Section 2517 (h) 119 Provide calculations for main vertical and l.4' If foundation cripple wall studs are less horizontal framing members and post footings. • an 14" framing shall be solid blocking. Section 302 (a) 7 Section 2517 (g) 4 120 Provide calculations for lateral loads, , shear panels, shear transfer and related. ' • , .' 0 • Section 302 (9) 7 (I) 4 Ki Cripple wall studs exceeding4 feet in t shall be '3 inch by 4 inch or 2 inches by 6 inches when supporting 2stories. Section 2517 (g) 4. Show plywood sheathing over exposed eaves, /or other weather exposed areas, is exterior grade. Section 2516 (g) 3. Xine Showa weep screed at the foundation plate n all exterior and stud walls to be stuccoed. Section 4706 (e). l" Sh ow corridor width to be minimum 36". Section 3305 (b). eo Xacce,sSp ecify truss layout for 30" x 30" attic Ridges, hips, and valleys shall be at ne size larger than supported rafters. Section 2517 (h) 3. In open beam' construction, provide strap ties across the beams at the ridge support. Section 2501 (b). V _14/Show, minimum 30" deep unobstructed working space in front'of furnace. Section 505, UMC. Note on plans, clearances to be per manufacturer's' listing'.. 'Section 504, UMC. Furiiace shall, not be installed under any 'stairway. Section 704, UMC.' rnace shall not be installed in any edroom, bathroom or in a closet or confined space with access only through such room, unless specified as direct vent appliance, enclosed furnace or electric heating appliance.' Section 704, UMC. ' V 1 . 'Show I.C.B.0. 'approval number for prefab fireplace. V 145. Show access to the attic or underfloor furnace to be minimum 30 inches by 30 inches. .Section 708 & 709 UMC. ' /X6 b ote that passageway to the 'attic furnace e unobstructed and have continuous solid floorinv not less than 91 inches wi,ic, ' Section'708, UMC. J. ME(ANICAL V V V iy Show permanent electrical outlet and All heating, ventilating, and cooling systems righting fixture controlled by a switch for the and appliances shall comply with the Uniform attic furnace. Section 708, UMC. Mechanical Code. , V ,' Showdetails to comply with Section 709 /Or-furnace 137 Show the size, location and type of all under the floor, or Section 710 for heating and cooling appliances or systems. V roof or outside furnace. ' 138,. Show source of combustionair to furnace, ' 9. Note on plan: Gas vents and ' per Chapter 6, UMC. 'V /noncombustible piping passing through three' V ' floors or less shall be effectively draft 139 Every dwelling unit shall be provided with MSheating facilities capable of maintaining a room stopped at each floor or ceiling UBC, Section 1706 (a) 6 temperature of 70 degrees F. at 3 feet above the V floor in all habitable rooms. Show basis for compliance. USC, Section 1211. -v3 crt a w K.. ELrRICAL (NATIONAL XLECMICAL (X)OE) Fuel combustion water heater shall not be lied in bath or bedroom or in a closet All wiring shall comply with the National opening into bath or bedroom Electrical Code UPC, Section 1309 Show on the plan the amperage of the Provide adequate barrier to protect water electrical service, the location of the service heater from vehicle damage UPC, Section 1310 panel and the location of any sub-panels /Show location of all electrical Show T and P Valve on water heater and ecelptacles..4how route of discharge line to exterior. UPC, Section 1007(e) Electrical receptacle locations and/or /Plcing is not adequate in lfrl' Provide dryer vent to outside 'UMC, Section 1903 Note on the plan that hose bibbs and lawn "sprinkler systems shall have approved backf low / prevention devices UPC, Section 1003 Show at least one convenience outlet other ,cthan outlets for laundry, etc., outdoors, in Shower stall shall accommodate a 30" gara3es and basements NEC, Art 210-52 "circle and have a minimum floor area of J 1,024 sq..in UPC, 909 (d) Note convenience outlets in bathrooms, iutdoors, and in garages and basements (other . M. NOISE INJLATION (WPLEXKS) than for laundry and similar equipment) shall be GFI protected, NEC, Art 210-8 Show details of duplex common (party) floor/ceiling assemblies to achieve a ,4'calls and Note electrical system ground to be /r9vi Sound Transmission Class (STC) rating in walls ded per NEC, Art 250-81 of 50 decibles and on Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibles. L PLUMBING (UNIFO1( PLUMBING CODE) Title 25.- /6. Show water heater size, type and location Show how penetrations of assemblies for /ip,ng, onlans UPC, Section 1310 electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or Show source forproviding combustion air /in exhaust ducts shall be sealed, lined, or uel burning water heater If wallopening insulated tomaintain required sound an enclosure are used, at least one-half of transmission rating. Title 25. the required opening area shall extend into the / upper twelve inches of the enclosure and 16/ Provide insulation in walls and ceiling to one-half within the lower twelve inches 6hieve STC of 50 between garage and living area UPC, Section 1307 if garage use is not controlled by resident Title 25 11 . .... . ... . 3/25/86 N. ENEWY (X)NSVAflON: PLEASE FMAD 11 . Specify on the building plans all of the mandatory energy conservation requirements as State regulations (California Adnin. Code) listed on the enclosure titled, "Mandatory require that the design satisy one of the Energy Conservation Requirements". - attached alternative energy packages or submit - calculations. The law also requires that man, Show the size, type, make, model and mandatory conservation items be satisfied, location of the space heating (or cooling) system and' provide heat loss calculations if the . Show on the Title Sheet of the plans, the ;;;'P output BTU/Hr. exceeds 45,000. required elements of the alternative energy package that was selected; and next to each 0 S..F.D. & DUPLEX SUPPLEKENT element show how you are complying with each element. If calculations were used, provide Energy conservation design should be for similar data on the plans. Xone 7 . See attached energy packages. 168 The plan sheet showing the required 11 Floor drains must have auto-prime elements of the selected energy package, and (city policy). listing the design elements showing compliance with that selected package, must be signed by ' .1/'i. Note exhaust fans cannot be ductless type either the owner or a licensed professional (city policy) i.e., architect, engineer or contractor. A design professional must note his/her' state-' /8..New residential units must be pre-plumbed license number. Section 1403 of Title 20. - , future solar water heating. Note "two roof jacks must be installed" where the water heater 169 Show on the plans the "R" value for the is in the one story garage and directly below walls, floors, ceiling and related areas)2 -' '' the most south facing roof (City Ordinance No. 8093). 17'. Show double glazing as per Energy Design, on. Glazing Schedule. - ' . Note "two 3/4" copper pipes must be /inslled - -' -, ta to the most convenient future solar ,Show on the plan how shading requirements Xare - panel location when the water heater is not in a satisfied. ' one story garage and' is not directly be-low the most south facing 'roof. - 17 . The plans are not in compliance with the - (City Ordinance No. 8093). - energy conservation compliance package selected or design calculations provided. Show on plans - - 1)6. All piping for present or future solar conformance as follows: - cater heating must be insulated when in areas - that are not heated or cooled by mechanical means (city policy). - • • Incorporate the waterproofing details, on - - - £he attached Policy 80-8, where interior living. - ' -• space occurs below grade at the masonry - - ' wall(s). - 12 - - - 3/25/86 Show on the Title Sheet on the plans, the USC Adopting Ordinance 8792-requires 7information required by the attached ,.. . Fire Retardant-roof on-all structures (Sec. 18.04.230). Show compliance Developmental Services Sheet 102683. with USC Section 3203(e). City Ordinance 9792'requires two park- All new residential buildings, including 7- ing spaces/unit-with clear area of additions, require a soils report. Please • S 20'x20'i.-nowashing machines, etc.. Show compliance. submit two copies. S 4. Heavy timber framing, minimum 6 x loll Seams and minimum 8u x 8 post, for the - -.-- .4 .. . - structural beam and column supporting the fire separation between the garage and living area '. . above, is acceptable if shown on the plans. -' (city policy). - Please see additional-corrections, or 'remarks, on the following page. The City of Carlsbad has contracted with Esgil - S Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; • - . . telephone number of 619/560-1468, to perform the , plan check for your project. If you have any questions regarding these plan check 'items, please contact - - at Esgil Corporation. If you have any questions- regarding City Building permit procedures, -• - - . - - please contact Carter Darnell at, the City of • : • - - - - - - Carlsbad, 1200 Elm-Avenue, telephone 619/438-5525. Thank you. • - -' -- : ..- . - Enclosures: . . -• -- 5 - - S -, - - '' 1 Ut2- 2.'00 (1 .'• S • • - -. .•.- ' - S • •,• '••• S - -- 4' • . 3. • • - . S • • - - S - - 13 - S - • - - . - - - S 10/6/86 - - ' •- •: I •-. -, - - -- ThE FOLLOWING ir SPECIFYfl3 MANDAICRY RE(UIRIENTS SHOULD BE .INCORPORATED ON PLAN SHXES, OR M(IAfl(D W1I1iLI4 JOB SPECIYICPIION 000J$ENTS. MANDATORY EN1MGY CONSERVATION R UIRF]IIS OF THE STATE OF CALIFORNIA All heating, ventilating, air conditioning, and water heating equipment shall meet all Of the requirements of the Appliance.Efficiency Standards and shall be certified by the California Energy Commission. S A two stage thermostat, which controls the supplementary heat on its second stage, shall be provided for heat pumps. Thermostats shall be equipped with an automatic setback, which the building occupant can program to automatically set back the thermostat twice, in 24 hours. (4)', Equipment which requires preventive maintenance to maintain efficient operation shall be furnished with complete necessary..maintenance information. (5) All gas-fired fan type central furnaces, gas-fired fan type wall furnaces, and cooking appliances shall be equipped with an intermittent ignition device. (6)' All fan systems-exhausting air to the outside shall be provided with backdraft dampers. All transverse duct, plenum, and fitting joints shall be sealed with pressure sensitive tape or mastic to prevent air loss and shall"be insulated to conform to the provisions of Section 1005 of the UMC,' '1982 Edition. A vapor barrier is required in' climate zone' 1, 14, and 16. 2(9) All manufactured windows and sliding glass doors shall meet the 1972, ANSI air infiltration standards and shall be certified and labeled. All swinging doors and windows leading to unconditioned areas shall be-fully weather-stripped. Storage type water heaters and storage and backup tanks 'for solar systems shall be externally wrapped with R-12 insulation or greater. ., (12). The five feet of pipe closest to the water heater,' if outside conditioned space, shall be insulated with a minimum of R-3. Steam' and steam' condensation return piping and recirculating hot water piping outside the building envelope shall be insulated.-in 'accordance with T20-1406(d). Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an 'efficiency of not less than 25 lumens'per watt. Showerheads and faucets shall be equipped with flow restrictors as outlined in the appliance efficiency standards and shall be certified to the Energy Commission. Masonry and factory-built fireplaces on exterior walls, shall be equipped with tight-fitting closeable metal or glass doors covering the entire opening of the firebox; a combustion air intake equipped with a readily accessible, operable, and tight fitting damper to draw air from the outside of the building; and a tight fitting flue damper with a readily accessible control. Insulation used shall comply with California Quality Standards. The insulation installer shall post. a 'signed certificate. . . Section 276.. Insulation Certificate (All Occupancies). After installing insulation, the installer shall post in a 'conspicuous location in the building a certificate signed by the installer and the builder stating that the installation conforms the requirements of Title 24, Part 2, Chapter 2-53, and that the materials' installed conform with the requirements of Title 20, Chapter 2, Subchapter 4, Article 3. The certificate shall state the manufacturer's name and material identification, the installed ttg, value, and (in applications of loose fill insulation) the minimum installed weight per square foot consistent with the manufacturer's labeled density for the desired tRII value. , For infiltration control all openings and penetrations must ,be caulked and sealed, such as around windows, at sole-plates, and openings for utility Pipes and wires. Form ECH 3/5/86 CITY OF CARLSBAD Table 7.4ternative Comlo limat.e Zone 7 A Ammcomam ffib"04 Building Measure rwAsignacion I Package sy - - - A B I C D E 2 3 I 0.1 51 6 NSULATLON R- VALUE MINIMUM (19 Ceiling 19 30 19 30 30 f 19 304 3 19 Wall . 11 11 11 11 11 11 1J.4 11 ' 11 "Heavy" Wall 2.5 2.5 2.5 NA NA 5 2.5 2. .5 2.5 Light Mass Wall 4.0 3.5 3.5 NA NA NA 'A N NA NA Slab Floor Perimeter MR 7 NR NR NA MR MR 7 MR Raised Floor . 11 11 11 NA 19 MR 19 11 11 ArrIC3 . MR MR MR REQ REQ JQ MR Rj MR MR4 .R GLAZING j Maximum U-Value 1.1 .65 1.1 .65 .65&J5 1 .65 1.1 5 .65 Maximum Total Area % MR 14 14 20 20 24/s 20 24A NR MR Maximum Total. Nonsouth Area . . 9.6 NA NA NA NA J JR NR .R 8.4 9.6 Minimum Total South 4 Area Z 6.4 NR MR MR NR MR MR 5.6 6.4 A South-ring Glazing R MR MR MR MR MR N MR MR MR MR West-ffing Glazing INR MR MR MR4 36 MR MR MR MR. MR Nort'f acing Glazin' MR MR MR MR MR JR MR MR MR MR 'Eas. acing Glaz i' MR MR MR MR NR4 MR MR MR IT rBEffAL MASS EQUI3 "ENT I' f 'Slab Floor sed7,.8 50 NR '7k 25. 5 25 20 l54R 50 ILTRAI ION A&ROL A Cont iriuoujarrier N1 MR MR MR ' MR MR NRA R MR MR lectrjca'ut1ec Plate MR MR NR A MR MR Nil MR NR MR Gasketff V Ltr-Tofr Heat Exchanges MR MR MR MR MR . N MR MR NFA MR ;PA HEATING SYSTEM V. or V Furnace Season A . .4 ' Efficiency Z ' HIM 1.T HIM HIM HIM HIM HIM Heat Pump ACOP .' 2.5 5 2.5 2.5 2.5 .5 2.5 2. .5 Electric Resice1' N NO NO NO Nj NO NO MO YES YES PACE COOLING STEM 4 Pr A/C or He - Pump SEER/ ATER HE 4G SYSTEM J' Gas, Pump or !ar ?RESolt wi,! Any Backup4" . REQ REQ REQ REQ EQ REQ R REQ with Cas çkup.REQ RE9' Appendix 8 B-9 C-70 ACP ii 'Table 17. Notes for Tables 1 through 16 '. LEGEND: ..NR - Not required, N/A' Not applicable, 'REQ - Required, MIN - Minimum efficiencies required .by Section 2-5306 of the regulation. NO - Heating system' type not allowed, YES Heating system type allowed. .3. Whenever an attic is required, it must cover at least three-quarters (3/4) of the ceiling area over conditioned apace and be vented. In alternative component packages which require thermal mass (other 'than Package A), the specified percentage of mass must be directly exposed to the conditioned space. To determine the floor area directly exposed to the conditioned space. To determine the f1o2r area, count only 'the first floor in conditioned, areas. Uncarpeted Afirst. floor areas, such as linoleum ortiled entry ways, kitchens, bathrooms, and utility closets may all be counted .towards this requirement. , Thermal mass required for Packages E,1,2,3 and 4 must be either equivalent to a slab floor covering one-fourth (25, percent) of the floor area' with a thickness of at least 2 inches and a volumetric heat capacity of 28 Btu./ft3 °F (see below fór'surface area of materials examples) or provide theminimum total mass capacity listed in Table 17 of Appendix A (use the Point System'to calculate the mass for other materials). ' 4" brick' Concreteblóck 90 pcf Concrete block 1,40 pcf Climate Slab exposed block density,' ' block density, solid Zone Floor. Z one side grouted grouted 4 6 4•• 6" 15 21 18 .17 14 13 20 28 24 ' ' 22 ' , 18 . 18 7 25 ' 35' ' 30 . 28 23 . . '. 22 Provisions of Assemblyman Condit's bill AS 2313 were amended into SB 790, authored by Senator John Seymour, which has been signed into law and became effective January 1, 1986. (Chapter 1327; Statutes Of 1985). This measure contains two important items: First, it cleared up a long-standing conflict between the Architects Act and the Engi- neers Act in which one act allowed plans to be prepared by certain individuals, while the other act did not permit this. The two acts are now the same. The second important item from the bill limits the architectural or engineering services that an unlicensed person may perform. •• The following' excerpt from the bill addresses the exceptions to the requirement that a licensed civil engineer or architect must sign plans. Section 6737.1 of-the Business and Profession Code is amended to read as follows: S Section 6737.1 (a) This chapter does not prohibit any p'erson from preparing plans, ' •• ' ' drawings or specifications for any of the following: . (1) Singie-family dwellings of wood-frame Construction not 0 •, , , more than two stories and basement in height. ' ' ' ' ' (2) Multiple dwellings containing not more than four dwelling •• ' ' ,. : units of wood-frame construction not more than two stories and basement in height However this paragraph shall not be construed as allowing an unlicensed person to design multiple clusters of up to four dwelling units each to form apartment or condominium complexes where the total ex- ceeds four units on any lawfully divide lot (3) Garages or other structures appurtenant' to buildings de- • ' • , : • • scribed under subdivision (a) of wood-frame Construction 0 not more than two stories and basement in height (4) Agricultural and ranch buildings of wood frame Construc- tion, unless the building official having jurisdiction deems • - : ' •• that an undue risk to the public health, safety and welfare is •. •• •• - ' •. involved. - • ' (b) Ifany portion of any structure exempted by this section deviates - •'••' - 0 from conventional framing' requirements for wood-frame Con- ' ' • 0 , ' , • ( structiOn found in Chapter 25 of the 1985 edition of the Uni- form Building Code or tables of limitation for wood frame / construction as defined by the applicable building code duly - - 5 0 ( adopted by the local jurisdiction or the state, the building -' • S • •, S •> official having jurisdiction shall require the preparation of • - • S • " • ( plans, drawings, specifications or calculations for that portion •. \ by, or under, the direct supervision of a licensed architect or S S • • registered engineer. The documents for that portion shall hoar - ( the stamp and signatures of the licensee who is responsible for their preparation Date 1 101 (tjp CITY OF CARLSBAD Prepared byt Bldg. Dept. VALUATION AND PLAN CHECK FEE o Esgil PLAN CHECK NO - BUILDING ADDRESS - FC P- J( APPLICANT/CONTACT PHONE NO 4-Z8 O 4-1C) BUILDING OCCUPANCY - DESIGNER PHONE_____________ TYPE OF CONSTRUCTION V CONTRACTOR PHONE___________ BUILDING PORTION BUILDING AREA VALUATION VALUE MULTIPLIER Air Conditiortinz Cornrneriia1 Residential Res or Comm Fire Sprinklers Total Value REDEVELOPMENT PERMIT REQUIRED: 'LANDSCAPE 'PLAN COMMENTS: ENVIRONMENTAL REQUIRED: ADDITIONAL COMMENTS: PLAN CHECK NO. ADDRESS V DATE 4.., PLANNING ZONE' 't. TYPE OF PROJECT AND USE SCHOOL DISTRICT: SAN DIEGUITO ____ ENCINITAS CARLSBAD. SAN MARCUS SETBACKS: FRONT" SIDE REAR ____ DISCRETIONARY ACTIONS: Al 104' . A ' OK TO ISSUE: DATE: ENGINEERING LEGAL DESCRIPTION VERIFIED? APN CHECKED? - PARK-IN-LIEU QUADRANT:__ , FEE PER UNIT: TOTAL FEE: P.F.F.LJ TRAFFIC IMPACT FEE PER UNIT: TOTAL FEE: FACILITIES MGMI. FEE:' & ' ' BRIDGE & THOROUGHFARE FEE:_____________ IMPROVEMENTS:Ak ' FIELD CHECK DATE & INITIALS:_' ' RIGHT-OE-WAY:_ DRIVEWAY: &/ . EASEMENT'5:'?Ur I V E.D.U.: p/fr' SEWER: LATERAL:_________________ - ' INDUSTRIAL WASTE PERMIT: '.• DRAINAGE:/' cr GRADING PERMIT: , ___' _GRADING COMPLETION CERTIFIED:ui ' ADDITIONAL COMMENTS: U-) z - a) ' iUQ ' • ' OK TO IS SUE ::f:f,,,, _----AJE://'/' DPD2;DPD6:07/17/86 I ' DAVID M. THOMAS AND-ASSOCIATES , - PLANNERS, ENGINEERS. LAND SURVEYO - qczu~)? !.O ,0x. 8OLANA BEACH, CAO75 (7I4181.16 .. . . August 30, 1982 City of Carlsbad Building. Inspection .......... . . - . 1200 Elm Ave. Carlsbad, CA 92008 . . . . . .. .: Subject: Compaction offill material for Bill GiUey's , '• . lot on Oak Avenue. ' '' . •' Dear Sirs: . .- . . . .. Attached please find a copy of the moisture cónteñt/dry.density curve and plat of compaction test for the above-mentioned, project. • '• •••• .- . . The soil compacted is amedium-density, brown, silty sand which is t'pical of the ' Oak Avenue and Canyon Street area. The fill material was compacted to at, least 90%'of the maximum density obtained by the proctor method. The fnill.material and its compaction are suitable for construction - of the proposed residence. No bearing values for 'the 'soil were determined by our office, .so-the code value of .1000 psf should be used for soil bearing pressure unless other information exists which allows the builder and designer to use a' higher value. - if you have any further questions regarding the grading of the site please don't hesitate-to give me a call. - .• . • ' -- Sincerely, DAVID M. THOMAS £ ASSOCIATES 7 David M. Thomas •- -' :- - - -- • - :. • -• - RCE 32256 -. ' • •- - . • • • S - - • .. 'S •5 - - -. - (