Loading...
HomeMy WebLinkAbout1811 ASTON AVE; 102; CB070109; Permit02-21-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB070109 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 1811 ASTON AVCBADSt 102 Tl Sub Type 2121201000 Lot# $66,360 00 Construction Type Reference # THE BLACKMORE CO 1,896 SF SHELL TO OFFICE IN DUST 0 NEW Applicant BLACKMORE FAMILY TRUST 1995 C/O ALLEN J BLACKMORE P O BOX 424 RANCHO SANTA FE CA 92067 Status Applied Entered By Plan Approved Issued Inspect Area Plan Check# Owner BLACKMORE FAMILY TRUST 1995 C/O ALLEN J BLACKMORE P O BOX 424 RANCHO SANTA FE CA 92067 ISSUED 01/16/2007 MDP 02/21/2007 02/21/2007 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee- Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $419 51 Meter Size $0 00 Add'l Reel Water Con Fee • $272 68 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee -$1394 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $0 00 Traffic Impact Fee (3105541) ' . $0 00 Traffic Impact Fee"(4305541) . ;$000 PLUMBING TOTAL , $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 ' Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees HMP Fee TOTAL PERMIT FEES $000 $000 $000 $000 $1,20775 $000 $000 $000 $000 $000 $3400 $8500 $271 00 $000 $000 $000 $000 77 $2,303 88 Total Fees $2,303 88 Total Payments To Date $2,30388 Balance Due $000 Inspector FINAL APPROVAL Date _Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions ' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Car!sbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been qiven a NQTICJLsimilar to this, or as to which the statute of limitations has previously otherwise expired <SP0 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad CA 92008 FOR OFFICE USE ONLY PLAN CHECK N EST VAL . tJ^r , * * Plan Ck Deposit Validated By Date "7-? 7-.m. Name Address City State/Zip Telephone #Fax# [3 APPJJCANT_n_Contractor n^gentjorpon_tractor_D Owner AgenUor_Owner_ Name [4 PROPERTY OWNER Address City State&p <- ' Telephoned ' o '• . . \ State/ZipfNameAddressCity Telephone # CONTRACTOR -COMPANYiNAME[5_ (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Address License Class City State/Zip City Business License #. Telephone # o Designer Name State License # Address City State/Zip Telephone # Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations D I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued J9 I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are OF ^*[£|2-| C-Ar- Insurance Company g£3^QOQ Ts|fZ£.Sc^>U&JJtVCC>. Policy No U)(g-SS^tSfffi Expiration Date__Q_£?4-Ql-|C?-"7- (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand do11ars($100,000). In addition to the cost of compensation, damages are provided for In Section 3706 of the Labor Code, interest and attorney's fees SIGNATURE DATE WARN C | dollars N^SIGN ' \i , I hereby affirm that I am exempt from the Contractor's License Law for the following reason D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) ^p I, as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractors License Law) D I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement D YES D NO 2 I (have/have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name /address /phone number /type of work) PROPERTY OWNER SIGNATURE WHITE File YELLOW Applicant PINK Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad CA 92008 Page 2 of 2 Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration for or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES & NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES ^ NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES A NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT ^""""CONSTRUCTION CGNDING'AGENCY J " ' """ " ' " ' """~ ^^ """ " "'""] I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(1) Civil Code) LENDER'S NAME LENDER'S ADDRESS [9~~r]APPj:ICANT 'C ERTIFICAT1ON ~~~~'T' |_'._^_"""" ^ ----- — —.-..-,.—...."~-"""-""1^-- '" """_'- ~~} I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND OSHA An OSHA permit is required for excavations of 5 0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a periQUof 18Q days (Secfion \06 4 4 Uniform Building Code) APPLICANT'S SIGNATURE ' ' V^-A- '"-—\|| — DATE.//T/&7 WHITE File YELLOW Applicant PINK Finance Inspection List Permit* CB070109 Type Tl INDUS! Date 05/17/2007 05/17/2007 05/16/2007 05/16/2007 05/01/2007 05/01/2007 04/25/2007 04/25/2007 04/25/2007 04/09/2007 04/09/2007 04/09/2007 04/09/2007 04/05/2007 04/04/2007 04/04/2007 04/04/2007 03/27/2007 03/27/2007 Inspection Item 89 Final Combo 89 Final Combo Final Combo Final Combo Rough Electric Final Electrical 89 89 34 39 14 34 44 14 24 34 44 17 14 24 34 21 31 Frame/Steel/Boltmg/Weldin Rough Electric Rough/Ducts/Dampers Frame/Steel/Boltmg/Weldin Rough/Topout Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Underground/Under Floor Underground/Conduit-Wmn Inspector TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP Act AP R[ Rl NR AP WC AP AP AP AP WC AP WC AP AP AP AP AP AP THE BLACKMORE CO 1,896 SF SHELL TO OFFICE Comments SUB PNL, TRANS T-CEIL CEILLITES DUCTS, H P s HARD CEIL & SOFFIT HARD CEIL & SOFFIT Friday, May 18, 2007 Page 1 of 1 City of Carlsbad Bldg Inspection Request For 05/17/2007 Permit# CB070109 Title THE BLACKMORE CO. Description 1,896 SF SHELL TO OFFICE Inspector Assignment TP 1811 ASTON AV 102 Lot Type Tl Sub Type INDUST Job Address Suite Location OWNER BLACKMORE FAMILY TRUST 1995 Owner BLACKMORE FAMILY TRUST 1995 Remarks Phone 6195203810 Inspector Total Time Requested By CLARK Entered By JANEAN CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# Date 05/01/2007 05/01/2007 04/25/2007 04/25/2007 04/25/2007 04/09/2007 04/09/2007 04/09/2007 04/09/2007 04/05/2007 04/04/2007 04/04/2007 04/04/2007 Inspection History Description 34 Rough Electric 39 Final Electrical 14 F ra me/Steel/Bo Iti ng/We Id ing 34 Rough Electric 44 Rough/Ducts/Dampers 14 Frame/Steel/Bo Hi ng/We Id ing 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers 17 Interior Lath/Drywall 14 Frame/Steel/Bo Iti ng/We Id ing 24 Rough/Topout 34 Rough Electric Act AP we AP AP AP AP we AP we AP AP AP AP Insp TP TP TP TP TP TP TP TP TP TP TP TP TP Comments SUB PNL, TRANS T-CEIL CEIL LITES DUCTS, H P S HARD CEIL & SOFFIT HARD CEIL & SOFFIT EsGil Corporation In (Partnership -with government for (Bui&fing Safety DATE 2/13/07 Q APPLICANT a JURIS JURISDICTION City of Carlsbad Q PLAN REVIEWER a FILE PLAN CHECK NO 07-109 ^ SET II PROJECT ADDRESS 1811 Aston Ave Suite 1O2 PROJECT NAME The Blackmore Co. - TI XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to X Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mai! Telephone Fax In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 2/7/07 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In (Partnership -with government for ftuiCding Safety DATE 1/26/07 Q APPLICANT JURISDICTION City of Carlsbad PLAN CHECK NO 07-109 SET I PROJECT ADDRESS 1811 Aston Ave Suite 102 PROJECT NAME The Blackmore Co. - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Richard Yen and Associates / Richard Cornelius 3515 Hancock Street Suite 250, San Diego, CA 92110 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Richard Cornelius Telephone # 619-224-3605 / / /Date contacted 1(7^(0^ i^^£>} Fax # 619-224-1530 Mail Telephone ^/^Fax }/ In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ n PC 1/19/07 trnsmtl dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 07-1O9 1/26/07 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO O7-109 OCCUPANCY B TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 1/16/07 DATE INITIAL PLAN REVIEW COMPLETED 1/26/O7 JURISDICTION City of Carlsbad USE Office ACTUAL AREA 1896 STORIES 1 HEIGHT OCCUPANT LOAD 32 DATE PLANS RECEIVED BY ESG1L CORPORATION 1/19/07 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot T9 City of Carlsbad 07-109 1/26/07 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/mdustnal projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGiI Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGiI Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver a!! remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE1 Plans that are submitted directly to EsGiI Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by • EsGiI Corporation is complete 1 In areas where the occupant load is at least 30, two exits are required See Office. Table 10-A. 2 Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served Section 1004 2 4 3 Exit signs are required whenever two exits are required Show all required exit sign locations Section 1003 282 4 If exit signs are required, provide the following notes on the plans, per Section 1003282 a) Exit signs shall be located as necessary to clearly indicate the direction of egress travel No point shall be more than 100 feet from the nearest visible sign. b) Exit signs shall be readily visible from any direction of approach 5 Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" 6 Please revise the single line diagram to show the grounding of the new transformer to be per section 250-30 A (4) of the NEC To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc 'J City of Carlsbad 07-109 1/26/07 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgii Corporation Thank you City of Carlsbad O7-1O9 1/26/O7 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO 07-1O9 PREPARED BY Doug Moody - DATE 1/26/07 BUILDING ADDRESS 1811 Aston Ave Suite 1O2 BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN BUILDING PORTION Tl • Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq Ft ) 1896 cb Valuation Multiplier 34.37 By Ordinance Reg Mod VALUE ($) 65,166 ' 65,166 $406 66 Plan Check Fee by Ordinance Type of Review [~l Repetitive FeeRepeats Complete Review D Other i—I Hourly Structural Only Hour* Esgil Plan Review Fee $264.33 $227.73 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 07- I 0 DATE 7 ADDRESS tax ASTPN! /W Surre: RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000.00) OTHER TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING PLANNER DATE ENGIN DATE H /Development Services/Masters/Applications Counter/Planning Engineering Approvals ENGINEERING DEPARTMENT ••5" FEE CALCULATION WORKSHEET Q Estimate based on unconfirmed information from applicant a Calculation based on building plancheck plan submittal \ni 1 3 O -J *v\ Address H0II M^l No Cx(-i>t?Y~' °^ Prepared bv (LV / EPU CALCULATIONS Types of Use 6r~Pi< Types of Use APT CALCULATIONS. Types of Use U\r I Types of Use On -TV ^-ft> |V^ Bldq Permit Date ( l^^l^l Checked bvI ' List types and square footages for all uses ts£j Sq Ft /Units 1%%/(OCO Sq Ft /Units List types and square footages for all uses T^) o i~t n i * ^V/cYOf) (1 ^rP~fl/},L_XI^ gq Ft /Units 7ruuu vl)i>'^k/y Sq Ft /Units Date EDU's , ^ "7" EDU's ) ADT's 2& ADT's I Ju W FEES REQUIRED- WITHIN CFD HTES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee)DNO PARK-IN-LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS 2 TRAFFIC IMPACT FEE ADT's/UNITS X FEE/ADT 3 BRIDGE AND THOROUGHFARE FEE (DIST #1 DIST #2 DIST #3 ADTs/UNITS AGILITIES MANAGEMENT FEE UNIT/SQ FT 5 SEWER FEE EDU's X FEE/ADT ZONE X FEE/SQFT/UNIT X FEE/EDU BENEFIT AREA F EDU's *FEE/EDU a 6 SEWER LATERAL ($2,500) D 7 DRAINAGE FEES PLDA ACRES X D 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE HIGH FEE/AC /LOW METER FEE SDCWA FEE IRRIGATION 1 Of 2 H \Developmenl Services\MASTERS\FORMS -MISCELLANEOUS \FEE CALCULATION WORKSHEET doc Rev 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9 RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE TOTAL OF ABOVE FEES* $ *NOTE- This calculation sheet is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits .tori A b'-s 2 of 2 H \0evelopmenl Services\MASTERS\FORMS -\MISCELLAN60US \FEE CALCULATION WORKSHEET cloc Rev 7/14/00 D a a & .o a a - - -o o o S c cR) (Q £X 0. 0. an PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB 070109 Address *- Planner Jo Marquez _ _ Phone- APN 212 120 10 00 _ A'i,? F ",«^t 1811 Aston Ave Suite 102 - (760) 602-4619 Type of Project & Use: - Tl . Zoning C-M General Plan CFD (in/out) # Date of participation Circle One Net Project Density PL Facilities Management Zone DU/AC Remaining net dev acres (For non-residential development Type of land used created by this permit Legend: ^ Item Complete (D)ltem Incomplete - Needs your action Environmental Review Required: . YESjl':'fit NO _X -TYPE ' ' "_ DATE OF COMPLETION fj,/, n , , * . ±, Compliance with conditions of approval9 If not, state conditions which require action Conditions of Approval ^DC' c ^ -. <j',uv ' t,i A »* Discretionary Action Required: APPROVAL/RESO NO PROJECT NO YES NO X TYPE OTHER RELATED CASES ' ' ' Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval ^ DD D Coastal Zone Assessment/Compliance Project site located m-Coastal Zone'? YES NO- X CA Coastal,Commission Authority9 YES NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619)767-2370 Determine status (Coastal Permit Required or Exempt) NO X Habitat Management Plan Data Entry Completed? YES ^ If property has Habitat Type, identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE') Inclusionary Housing Fee required: YES NO X (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed'? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE") H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 [H D Site Plan: ><>>••,,.,* 5 ".*-',^ Provide a fully dimensiohaf site plan drawn to scale '' Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal, description of.property and assessor's parcel-number -( Policy 44 --Neighborhood Architectural Design Guidelines D D 1 Applicability'"'1 YES * '' ' NO' - * - ' * jtr t •>, • !« . ' ' D D 2 Project complies YES _ NO _ Zoning: D D 1 Setbacks Front Interior Side' Street Side Rear Top of slope CD CH 2 Accessory structure setbacks Front Required Interior Side Required Street Side Required Rear Required Structure separation Required D D 3 Lot Coverage Required Required Required' Reauired Required Required Shown Shown Shown , Shown Shown Shown Shown" Shown Shown Shown Shown 4 Height Required Shown D D 5 Parking Spaces Required Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments Correction #1- Please show on sheet'1 the total number of parking spaces ~ " Provided and required on site for each-use per Chapter 21 44 - Correction #2- Is there any proposed roof mounted equipment associated with this building permit1?' If so. will the equipment be screened bv an existing parapet wall or is new screening material required'? Please see the attached handouts for examples OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 SCREENING OF EQUIPMENT: Exterior components of pluming, processing, heating, cooling, and ventilating systems (including but not limited to piping, tanks, stacks, collectors, heating, cooling, and ventilating equipment fans, blowers, ductwork, vents, louver, meters, compressor, motors, incinerators, ovens, etc....) shall not be directly visible from a height of five feet above any ground or ground floor elevation at a distance closer than 500 feet from the closest building wall on any lot. Please provide a display of proper screening material and/ or parapet wall on site plan. See example below. EXAMPLE OF SCREENING MATERIAL DISPLAY: Vf WTXX Vf Wf \S \ji\S\A \S Carlsbad Fire Department Plan Review Requirements Category TI, INDUST Date of Report 01-23-2007 Name Address Reviewed by Permit # CB070109 Job Name THE BLACKMORE CO Job Address 1811 ASTON AV CBAD St 102 BLDG. DEPT COPY Submitted for review IS mrnmplptp ^^j^timp tkig-Q£aaa-aaiM*nt adequately conduct a review to determine com]^tf^-**tt^SB^|^^ review carefully all comrnents^aiiaabgdi1 'I'lUWL iL^ulunit the necessary plans and/or specifications, with J^b*i^l!LU loi iLkinv and approval Conditions: Cond CON0001821 [MET] No Comments Entry 01/23/2007 By MS Action AP FROM Gr.DAC S134697S21 Dec 13 2006 S3 47AM P2 CERTIFICATE OF COMPLIANCE (Pan 1 of 2) MECH-1-C PROJECT NAME Blackmore Company T PROJECT ADDRESS DATE 1811 Aston Ave Carlsbad PRINCIPAL DESIGNER - MECHANICALGreater San Diego Air Conditioning Co Inc DOCUMENTATION AUTHOR Greater San Diego Air Conditioning Co Inc TELEPHONE(619)469-7818 1 TELEPHONE(619)469-7818 12/13/2006 Building Permit # Chackeci by/Dale Enrp Tre mant Ag an cy lG£NERAL INFORMATION DATE OF PLANS 12/08/06 BUILDING CONDITIONED FLOOR AREA BUILDINQ TYPE ! PHASE OF CONSTRUCTION I METHOD QF MECHANICAL j COMPLIANCE 1)0 NONRESIDENTIAL |2<( NEW CONSTRUCTION jXj PRESCRIPTIVE HIGH RISE RESIDENTIAL • CLIMATE ZONE 1.804 »qFi__ I 7 1 HOTEL/MOTEL GUEST ROOM ADDITION ALTERATION UNCONDITIONED vF"!ie Affidavit) | J PERFORMANCE PROOF OF ENVELOPE CPMPLfANCE PREVIOUS ENVELOPE PERMIT ENVELOPE COMPLIANCE ATTACHEC I STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24 Parts 1 and 6 of the California Code ctf Regulations, This certificate applies only to building mechanical requirements The documentation preparer hereby certifies that the documentation Is accurate and complete. /DOCUMENTATION AUTHOR i _______ T.L. Harmon _ _.__._. _ ____ I The Principal Mechanical Dasigner hereby certifies that the proposed building design represented in this set of construe ! documents is consistent with the other compliance forms and worksheets, with the soecificat'one. and with any otnor calculations submitted with this permit application The proposed building has been designed to meet the mechanical requirements contained in the applicable parts of Sections 100, 101 102, 110 through 11 5 120 through 125, 142, 144 and 145 LJ Tn6 o\an& & specifications meet Ihe requirements of Pan 1 (Sections 10-103a) | I _ | The installation certificates moel the requirements of Part 1 ( 10-1 03e 3) ! I The operation & maintenance information meets ma requirements of Pan 1 (10-103cl Please check one rrncs.6 Sft-tlonsof tne Bu^nes-i and Professrons Code are prtnlad In full In the Kionreslaenlla' Manual \ I I l ifirebv sffir-r Inat I am eligible under tne croviaions of Divsior- 3 of tne Business and Profeaaions Codu to sigr this Ootumenl as fno responwhle for us preparation and lha' I am ttcensea in the State of Calnorme as a crvii engineer or mecrwmcal er\gir*er or I air a lii^n£t»d arcnltecl i ] i I affirm trial I am eligible unrte-' Ihe exemption to Division 3 of the Business ana Professions Code Dy Section 5537 2 or 5737' 3 tc sign trite document as the person responsible fa-- its preparation anc that I am a licensed confaetor performing (his work I affirm fiat I BIT ehojEHc under ins exemption tc Division 3 of the Business ana Professors Code la sign tnls docLmenl because f penains ic a structure ot type of work described pursuant to Business and Professions Cocte sections 5337 SS36, ana 6737 1 PRINCIPAL MECHANICAL DESIGNER - NAME _Qrfiaier_$an Diego Air Conditipning_CQ. Inc SIGNA / . APPLICANT MECH-1-C Certificate of Compliance Part 1, 2, 3 o'l are requrred on plans for all submittals r> AirA'Vater/ServicoAVat^r Pools Requirements Part 1 of 3, 2 of 3, 3 of 3 are recurred lor all suomrtials, but may be on plans ? WECH-3-C Mechanical Ventilation and Reheat is required for al1 submittals with mechanical ventilation, but may be on plans 3 MECH-4-C HVAC Misc Prescnptive Requirements is required for all prescnptrve suiDmfttd/s, oa: may ce on plane U MECH-5-C Mechanical Equipment Details are required for all performance submittals 5 by En Usei Nuimer $'. "2 Job Nur-oer off J "4 ACORD^ CERTIFICATE OF LIABILI PRODUCER OA99520 1-619-234-6848 Cavignac & Associates 450 B Street, Suite 1800 San Diego, CA 92101-8005 INSURED Reno Contracting, Inc 1450 Prazee Road, Suite 100 San Diego, CA 92108 TY INSURANCE DATE (MM(DD/YY) 02/22/07 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW INSURERS AFFORDING COVERAGE INSURERA Redwood Fire & Casualty Insurance INSURER B Travelers Property Casualty Co of Co America INSURER G INSURER D INSURER E COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS EXCLUSIONS AND CONDITIONS OF SUCH POLICIES AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSRLTR B B A TYPE OF INSURANCE GENERAL LIABILITY X X _GEf- AUT X COMMERCIAL GENERAL LIABILITY | CLAIMS MADE | * | OCCUR PD Ded $10,000 L AGGREGATE LIMIT APPLIES PER POLICY Fl^T HLOC OMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON OWNED AUTOS GARAGE LIABILITY I ANY AUTO i EXCESS LIABILITY~~~i r~i| OCCUR | J CLAIMS MADE HDEDUCTIBLE RETENTION $ WORKERS COMPENSATION AND EMPLOYERS LIABILITY OTHER POLICY NUMBER ^^Sf DTEC08023B43A06 DT8108023B43A06 W6834379 08/01/06 08/01/06 08/01/06 POLICY EXPIRATIONDATE IMM/DD/YY1 08/01/07 08/01/07 08/01/07 LIMITS EACH OCCURRENCE FIRE DAMAGE (Any one (ire] MED EXP (Any one person) PERSONAL SADV INJURY GENERAL AGGREGATE PRODUCTS COMP/OPAGG Employee Benefits COMBINED SINGLE LIMIT (ET accident] BODILY INJURY(Per person] BODILY INJURY(Per accidenl) PROPERTY DAMAGE (Per accidenl) AUTO ONLY - EA ACCIDENT AUTOONLY ,__Abb EACH OCCURRENCE AGGREGATE v 1 WCSTATU 1 IOTHA 1 TORY LIMITS 1 1 ER EL EACH ACCIDENT EL DISEASE -EA EMPLOYEE EL DISEASE -POLICY LIMIT $ 1,000,000 $ 300,000 S 5,000 S 1,000, 000 $ 2,000,000 S 2,000,000 1,000, 000 $ 1,000,000 S S $ S S S $ S S S S $ 1,000,000 $ 1,000,000 S 1,000,000 S s I Certificate holder is named as additional insured with respect to General Liability per CGD248 08/05 10 days notice of cancellation for non-payment of premium Reno Job #07418 - Tenant Improvements to 1811 Aston Avenue, Suite 102, Carlsbad, CA 92008 Any alteration to the cancellation clause does not apply to the workers' compensation policy CERTIFICATE HOLDER ADDITIONAL INSURED INSURER LETTER CANCELLATION Allen Joseph Blackmore - Trustee of the Blackmore Family Trust - Restated 1995 Colleen Blackmore 1530 Faraday Avenue Suite 170 Carlsbad, CA 92008 USA 1 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF THE ISSUING INSURER WILL #*¥W3H^ MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT BXKX3UtXIKKXti£&}BCK9tlfi)tKX >ax»»m}rax)eaG«K*«2ffiKjraitmxxx4N^ Xft}^gaUEi$XK%XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX AUTHORIZED REPRESENTATIVE *^J% ffi^ ACORD 25-S (7/97) ufenton5701937 ©ACORD CORPORATION 1988 J COMMERCIAL GENERAL LIABILITY THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. BLANKET ADDITIONAL INSURED (CONTRACTORS OPERATIONS) This endorsement modifies insurance provided under the following COMMERCIAL GENERAL LIABILITY COVERAGE PART 1 WHO IS AN INSURED - (Section II) is amended to include any person or organization that you agree in a "written contract requiring insurance" to include as an additional insured on this Cover- age Part, but a) Only with respect to liability for "bodily injury", "property damage" or "personal injury", and b) If, and only to the extent that, the injury or damage is caused by acts or omissions of you or your subcontractor in the performance of "your work" to which the "written contract requiring insurance" applies The person or organization does not qualify as an additional insured with respect to the independent acts or omissions of such person or organization 2 The insurance provided to the additional insured by this endorsement is limited as follows a) In the event that the Limits of Insurance of this Coverage Part shown m the Declarations exceed the limits of liability required by the "written contract requiring insurance", the in- surance provided to the additional insured shall be limited to the limits of liability re- quired by that "written contract requiring in- surance" This endorsement shall not in- crease the limits of insurance described in Section III - Limits Of Insurance b) The insurance provided to the additional in- sured does not apply to "bodily injury", "prop- erty damage" or "personal injury" arising out of the rendering of or failure to render, any professional architectural, engineering or sur- veying services, including i The preparing approving, or failing to prepare or approve, maps shop draw- ings, opinions, reports surveys, field or- ders or change orders, or the preparing, approving, or failing to prepare or ap- prove, drawings and specifications, and ii Supervisory, inspection architectural or engineering activities c) The insurance provided to the additional in- sured does not apply to "bodily injury" or "property damage" caused by "your work" and included in the "products-completed op- erations hazard" 3 The insurance provided to the additional insured by this endorsement is excess over any valid and collectible "other insurance", whether primary, excess, contingent or on any other basis, that is available to the additional insured for a loss we cover under this endorsement However, if the "written contract requiring insurance" specifically requires that this insurance apply on a primary basis or a primary and non-contributory basis, this insurance is primary to "other insurance" available to the additional insured which covers that person or organization as a named insured for such loss, and we will not share with that "other insurance" But the insurance provided to the additional insured by this endorsement still is excess over any valid and collectible "other in- surance", whether primary, excess, contingent or on any other basis, that is available to the addi- tional insured when that person or organization is an additional insured under such "other insur- ance" 4 As a condition of coverage provided to the additional insured by this endorsement a) The additional insured must give us written notice as soon as practicable of an "occur- rence" or an offense which may result in a claim To the extent possible, such notice should include i How, when and where the "occurrence" or offense took place, ii The names and addresses of any injured persons and witnesses, and in The nature and location of any injury or damage arising out of the "occurrence" or offense CG D2 48 08 05 2005 The St Paul Travelers Companies, Inc Page 1 of 2 COMMERCIAL GENERAL LIABILITY b) If a claim is made or "suit" is brought against the additional insured, the additional insured must i Immediately record the specifics of the claim or "suit" and the date received, and II Notify us as soon as practicable The additional insured must see to it that we receive written notice of the claim or "suit" as soon as practicable c) The additional insured must immediately send us copies of all legal papers received in connection with the claim or "suit", cooperate with us in the investigation or settlement of the claim or defense against the "suit", and otherwise comply with all policy conditions d) The additional insured must tender the de- fense and indemnity of any claim or "suit" to any provider of "other insurance" which would cover the additional insured for a loss we cover under this endorsement However, this condition does not affect whether the insur- ance provided to the additional insured by this endorsement is primary to "other insur- ance" available to the additional insured which covers that person or organization as a named insured as described in paragraph 3 above The following definition is added to SECTION V -DEFINITIONS "Written contract requiring insurance" means that part of any written contract or agreement under which you are required to include a person or organization as an additional in- sured on this Coverage Part, provided that the "bodily injury" and "properly damage" oc- curs and the "personal injury" is caused by an offense committed a After the signing and execution of the contract or agreement by you, b While that part of the contract or agreement is in effect, and c Before the end of the policy period Page 2 of 2 © 2005 The St Paul Travelers Companies, Inc CG D2 48 08 05 £§6 £ = * !. o 52 3 TO FROAPPLICANT APPt••*, -^^ Nc; i-,•^ •^ C 1 t rs« j ^ 2ofe «Se 00 dfe^rf|3 w ^ s^s_ O I- •"-"!- ./"' No N ^ X-)\J JP VjJ -f ^ ^) f Js ^5o\ ^SA r' _^^a^^ r^o "5" -3L ^ H K, -o ^2 ^