HomeMy WebLinkAbout1812 GUEVARA RD; ; CB090564; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
04-07-2009 Patio/Deck Permit Permit No: CB090564
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
Project Title:
Applicant:
1812 GUEVARA RD CBAD
PATIO
1562701700 Lot #: 0
$2,500.00 Construction Type: NEW
CONTRERAS RES-BUILD 56 SF
BALCONY OFF 2ND STORY MSTR BEDROOM ( PER CITY
Owner:
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
RAUL TARANGO
1070 BUENA PL
CARLSBAD
CONTRERAS CHARLES J&MARY
92008
760 729 5793
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Strong Motion Fee
Green Bldg Standards (SB1473) Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Additional Fees
TOTAL PERMIT FEES
1812 GUEVARA RD
CARLSBAD CA 92008
ISSUED
04/03/2009
LSM
04/07/2009
04/07/2009
$54.11
$0.00
$35.17
$0.00
$1.00
$1.00
$0.00
$0.00
$20.00
$0.00
$111.28
Total Fees: $111.28 Total Payments To Date: $111.28 Balance Due:
Inspector: t'\I\ ~ FINALAPPR
Date: 06 08
VAL
o'9 Clearance:
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as 'fees/exactions.' You have 90 days from the date this pem,it was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municlpal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
re.view, set aside. void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f Ix inf hih hv rvi I n ivnaN TICEsimilrtohisor whihthes ut flimi i h I hrwi
'Cii:y of Carlsbad
1635 Faraday Ave., Carlsbad, CA 92008
760-602,2717 / 2718 / 2719
Fax: 76()-602-8558
www.carlsbadca.gov
Building Permit Application
CT/PROJECT#
EXISTING USE PROPOSED USE
CITY
EMAIL
# BEDROOMS
GARAGE (SF)
ra..s
ZIP
STATE LIC. #
Plan Check No.
Est. Value
Plan Ck. Deposit
Date 1-/3/ CA
SUITE#/SPACE#/UNIT#
# BATHROOMS TENANT BUSINESS NAME
PATIOS (SF) FIRE SPRINKLE~
YES • NO
ADDRESS
CITY
FAX
CONTRACTOR BUS. NAME
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
STATE LIC.# CLASS CITY BUS. LIC.#
lSec, 7031.5 Business and Praftssions Code: Any City or CountJ: which nires a ptnnit to constnict, alter1_~~t ~mol~h or rep].ir lllJ struct_urt, prior IO ia issuaRtt, abq rtquim the a,pliant for sach permit IO lilt a signed statement that ht i1 ~cel'l$MJ!.l!rsuant to 1ht plV'fisions of the Conttactor's Licenst Law {Ch 9, aimmending with Section oocr of Dmsion 3 of lht Bllsiness and Proteslions Code} or that ht is nempc lhmli1111, and the basis for the alepd eiemption. Any ,iolation of Section Til3 LS by 111)' applicant for a permit 1ulljects tht ap~iant to ci,il penalty of not IIIOll than fi¥e hundred dollan {$500}).
WORKERS' COMPENSATION
Workers' Compenntion Declaration: / hereby affirm under penalty of perjury one of the fol/owing declarations:
D I hive •d will maintain a certificate of conaant to Hlf-lnsure for workers' compensation as proYlded by Section 3700 of the Labor Code, for the perform area of the work for which this permit is Issued.
0 I have and wlll maintain workers' compenllllon, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued. My workers' compensation Insurance earlier and policy
number are: Insurance Co. _____________________ Policy No. ______________ Expiration Date _________ _
This section need not be completed ii the permit Is for one hundred dollars ($100) or less.
0 Certfflcate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Fallura to secure worka'I' compenaallon coverage Is unlawful, and shall subject an employer to criminal penalties and clvll flnn up to one hundred thouaand dotlars (&100,000), In
addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, lnlarell and attorney's fees.
25 CONTRACTOR SIGNATURE DATE
OWNER-BUILDER DECLARATION
I he~ affirm that I am exempt from Contractor's License Law for the following reason:
,Jr I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contracto~s
License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. II, however, the building or improvement is sold within one year of completion, the owner-bullcler will have the burden of proving that he did not build or improve for the purpose of sale).
• I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contracto~s) licensed pursuant to the Contractofs License Law).
• I am exempt under Section ____ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property Improvement. • Yes • No
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. I ~an to provide portions of the work, but I have hired the following person to coordinate, supeivise and provide the major wOl'k. (include name/ address/ phone/ contraclOfS' license number):
5. I will provide some of the work, but I have ed (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work):
Js the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 Of 25534 of the
Presley-Tanner Hazardous Substance Account Act? • Yes • No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? • Yes • No
ls the facllity to be constructed within 1,000 feet of the outer boundary of a school site? • Yes • No
IF ANY OF THE ANSWERS ARE YES, A ANAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there 1s a construction lending agency for the performance of the work this permit 1s issued (Sec. 3097 (i) Civil Code).
lender's Name lender's Address
APPLICANT CERTIFICATION
I certify that I have read the appllcat!on and state lhatlhe aboYe Information Is correct and that the lnfonnatlon on the plans Is accurate. I agree to comply with all City ordinances and State laws relatlngto building construction.
I hereby aulharize ..,,_ .. a the Cily a Carlsbad to enter....., the -mentoned prope,ly for nspeclion PUIJ)«eS. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINSf Ali LIABILITIES, JUDGMENl'S, COSTS AND EXPENSES WHICH MAY IN />/NWAY ACCRUE AG,'JNST SAID CITY IN CONSEQUENCE OF THE GRANTING OFTHIS PERMIT.
OSHI'. An OSHA pennl il required for excavations <Ne! SU' deep and demolikln ex coostruction a slructues oo,r 3 sfories n heg,I.
EXPIRATION: Every pennlt issued by the · Official lllder the prolisioos of this Cooe shal expire by linilaoon and beccrne nul and voki f 1he buiklhg or \Wrk: authorized by such permit Ls net COIi II neuced wthil
180 days mm the dale of such penn! ex · aulhorized by such pennlt • suspended or-doned at any line alter the llorl<D•AToorm,enredE ll> :~: ~(}180: (Sectkln 1116.4.4 Unlonn Bui~ng Code).
25 APPLICANT'S SIGNATURE \ V 6-f I I
City of Carlsbad Bldg Inspection Request
For: 06/05/2009
Permit# CB090564 Inspector Assignment: MC
Title: CONTRERAS RES-BUILD 56 SF
Description: BALCONY OFF 2ND STORY MSTR BEDROOM ( PER CITY
SPECS) W/FRENCH DOORS & ELECTRIC FOR LIGHT
Sub Type:
---
Type:PATIO Phone: 7608140442
Job Address: 1812 GUEVARA RD
Suite: Lot: 0
Location:
OWNER CONTRERAS CHARLES J&MARY
Owner: CONTRERAS CHARLES J&MARY
Remarks:
Total Time:
CD Description Act Comments
Inspector: M (.,
Requested By: RAUL
Entered By: CHRISTINE
19 Final Structural 'VI "4.JAtl>IZ-AU.-: 9.;;£ u-pf?-
~.€~ ~ . .-.£~L. ~.
~ ~ eaL-AA..\~--··~·· .'El~ .~· ~AAf\~ -r"-44 ~ ~,_g-·····-
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
Inspection History
Date Description
05/22/2009 11 Ftg/Foundation/Piers
04/14/2009 11 Ftg/Foundation/Piers
Act lnsp Comments
AP MC 3RD FOOTING
PA MC 2 OF 3 FOOTINGS & POST BASES
City of Carlsbad
BUILDING DEPARTMENT
1635 Faraday Avenue, Carlsbad, CA 92008
Phone: 760-602-7541/ Fax: 760-602-8558
Plan Checb Comments / 2007 Codes
To: Co\JT'?-.tl2--,"<;S ~.!-, From: SteveBorossay
Fax: Pages:
Phone: "J'-~ _ 'o 7 93, Date:
Re: C'I? Q__:}: O s=G t..f-. Address: l8 \'2.-0 UE..~
--•-W¼fu,@4+it11i+M+iiii'if1{diiiM@iOdi·&i\ii,h:iiii
❖ Please make corrections referred to below and run TWO new prints. If red marks are on plans as
a part of this Plan Check response please return red marked set with the new prints.
❖ This Is a BUILDING review only. Comments or approval do not apply to any other City department
review. For information on the status of approval from other departments please contact staff
@760-602-2717 / 2718 / 2719.
4 )C 4-\A,u.."'
I\).) I z,... y,z__,, 9 K. \2:, -s
/lA.>O \--
\
I
i~
(
\
Allowable Joist Sizes
Joist Span Joist Span Joist Spaclnl Size of
Doull•• Fir Redwood Joist
6'3" 6'3" 12·
5'6" 5'6" 16" 2x4
5'0" 5'0" 24"
9'9" 9'9" 12"
8'9" 8'9" 16" 2x6
7'9" 7'9 24"
12'9" 12'9" 12·
11'9" 11'9" 16" 2x8
10'2' 10'2" 24"
16'5" 16'5" 12"
15'0" 15'0" 16" 2 X 10
13'0" 13'0~ 24"
20'0" 20·0· 12"
18'0" 18'0" 16" 2 X 12
15'10" 15'10" 24"
22'9" 22'6" 12·
19'9" 21'0" 16" 2 X 14
16'0" 17'0" 24"
1. Assumes a live load of 40 psi and a dead load of 8 psi.
2. If Joists are within 1e· of grade, use pressure treated Douglas Fir-Larch or Foundation Grade Redwood
3. Assume F(b)=825 psi, F9v)=90 psi, and E=1,200,000 psi for D.F. #2
4. Assume F(b)=925 psi, F9v)=80 psi, and E=1,200,000 psi for Redwood
Allowable Beam Sizes
/', Joist Span (in feet)
Post
Spaclnl I '4 8 8 10 12 14 18
~
4 4x4 4x6 4x6 4x8 4x 10 4 X 10 4 X 14
8 4x6 4x8 4x8 4 X 10 4x 10 4 X 14 4 X 14
6x8 6x8 6 X 10 6 X 12
8 4 X 10 4 X 10 4 X 12 4x 14 4x 14 4 X 14 4 X 16
6x8 6x8 6 X 10 6 X 10 6x 10 6 X 12 6 X 12 --...
1~ .t v 1n 4 X 14 4 X 14 4 X 16 4 X 16 4 X 18
I 10 l6x 10 / 6 X 12 6 X 12 6 X 14 6x 14 6 X 14 6 X 16
\ I -
12 4 X 10 4 X 14 4 X 14 4 X 16 4x 16 4 X 18 6 X 16 6 X 10 6 X 12 6 X 12 6x14 6x 14 6 X 14
SETBACKS FOR R-1 PARCELS
, • , , FRONT Y ARO -20' from front
property line
INTERIOR SIDE Y ARO -1 0% o1
lot width up to • maximum o!
10'
STREET SIDE Y ARO -1 O'
REAR Y ARO -20% o! lot width
up to meximt.M'n of 20 feet
MAX, LOT COVERAOE -40%
Contact the Planning Oepertmenl
fOf" Information on corner Iota or
Iota wlh unusual configurations
and !or Information on Planned
Commt..M"\lfea, .ccessory
structuraa, and building
heights.
The telephone number !or the
Plannlna Deo•r1mert la
602-460 I.
10%
20% 01 LOT
REAR Y ARO WIDTH TO A
MAX. OF 20'
EXISTING RESIDENCE
~ C ORAINAOE 2% MIN. --------'1-
20'
STREET
Minimum Square Footing Sizes (inches)1•2
Post Joist Span (in feet)
Spaclne ~
I 4 } 8 8 10 12 14 18
4 \d 14 16 18 20 20 22
8 14 16 20 22 24 24 28
~ ~ 20 22 24 26 28 30
I 10 ) 18 ) 22 24 28 30 32 34
v 'w 24 28 '32 32 36 36
1. Assumes 1,000 psf soil bearing capacity
2. The minimum depth for all footings is 12 inches into natural grade
10%OF
18
24
30
32
36
38