Loading...
HomeMy WebLinkAbout1818 ASTON AVE; ; CB941641; PermitBUILDING PERMIT Permit No: CB941641 03/09/95 15:57 Project No: A9402424 Page 1 of 1 Development No: Job Address: 1818 ASTON AV Suite: Permit Type: INDUSTRIAL TENANT IMPROVEMENT Parcel No: Lot# : Valuation: 650,000 Construction Type: IIIN Occupancy Group: 82 Reference#: Status: ISSUED Description: 57300 SF OFFICE/MFG COBRA Applied: 12/12/94 Apr/Issue: 03/09/95 - 1006 03/09/95 0001 01 02 C-PRMT 42291 *OO Entered By: DC Atml/Ownr : BLACKMORE PARKVIEW ASSOCIATES 619 792-1212 _- . 12626 HIGH BLUF CONTRACTOR : RENO CONS x** Fees Require Fees : Adjustments: Total Fees: Fee description _-_-____________-- Building Permit Plan Check Strong Motion Fee Enter Number of ED11 * BUILDING TOTAL Enter "Y" for Plumbing Issue Each Plumbing Fixture or Trap > 67 7.00 Each Install/Repair Water Line > 1 7.00 Each Water Heater and/or Vent > 1 7.00 Gas Piping System > 1 7.00 Each Vacuum Breaker > 2 7.00 Other > 3.00 * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Remodel/Alter Per AMP > 2000 .25 x ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > 31 9.00 Each Exhaust Fan > 10 6.50 Each Hood > 6 6.50 619 462-7025 Cr ed i t. s x** .oo 1,576.00 42,291.00 Ext fee Data 2490.00 1619. 00 137.00 15912.00 8825.00 8147.00 2757.00 2545.00 42432.00 469.00 7.00 7.00 7.00 14.00 3.00 GAS OTI 527.00 500.00 510.00 15.00 Y 279.00 65.00 39.00 20.00 Y 10.00 Y PFSNlT APPLICATION City of Carlsbad Buildinn Department 2075 Las Pal- Dr., Carlgbad, CI 5'2ooP (619) 436-1161 1. From list 1 (see back) give code of Pennit-Type: CTf ......................................................... For Residential Projects Only: From List 2 (see back) give Code of Structure-Type: 9939 12/12/94 0001 01 02 1576.00 C-PfHT Net WGain of Dwelling Units I FOR OFFICE USE ONLY 2 PR(1IEcFDWORMATlON Hullding or Suite No. Address 1018 A 5mC, AU6. # OFSTORIES 2 # OF BEDROOMS # OF BATHROOMS (it artterent from appllcantJ NAME (last name first) ADDRESS Workcn'ti,mpen%auon Dcclaramn: 1 h?reby allmll lhal I have a ccruI~calc 01 cunsml lo ~II-lnsure lsuW by 1he Uire~lor 01 lnduslnal Ilelarians, or a ccnilicare of Workm' Cumpenralion Insurance by an admirrrd insurer, or an exacf copy or duplirale thereof cerrificd by the Diwxtor of [he insurer thereof filed with the Building Inrption hpanmvnt (Seclion 3800, lab. C). POLICY NO. EYPIRA'IION DATE INSURANCE COMPANY Cemtcate ot Exempuon: I celfi so as to become subject to the W?rkers* Compensation Laws of California. that in the pertarmance 01 the work tor Whlch this permit IS ISSUW, I Shall not employ any person in any manner SIGNATURE DATE Owner-Builder Ueclarauon: 1 hereby attirm that I am exempt from me wantractors wcense Law tor the tollawing reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: Ihe Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who dm such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion. the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to consVUct the project [Sec. 7044, Business and Professions Code: The Contractor's License Law dm not apply to an owner of property who builds or improves rhereon, and contram for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section (See. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 Of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). m 0 0 0 Business and Professions Code for this reason: SIGNATURE DAm Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 1s the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Is the faciliw to be constructed within 1.000 feet of the outer boundaw of a schml site? 0 YES 0 NO 0 YES 0 NO LENDER'S NAME LENDER'S ADDRESS I CP~W thr I ~SVP read the anni,carmn and state that the above intormation 1s comect. 1 amee to comply wlth all Clw ordinances and stale laws . .... ~, ..-. _rr ~~ ~~~~~ ~~ relaling IO building consmclim. I hereby authorize represc&ives of &e City of Carlrbd to her upon ihi above menribned propeny for inspection purpo~~~ I AISO MRFX TU SAVE INDFM'MNIFY AND KEEP HAMLES nw tm OF CARLSBAU Acmsr ALL IJAII~, JUDGMFNE, arilS AND I'WEYSW WtllCII MAY IN ANY WAY ACCRUI! AGAINST SAID CTIY IN ODNSEQUFNCE OF 1HE CWIPIC OF 110s PFW. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of StNCNres over 3 stories in height Expiration. Every permit iss building or work authorized such permit is suspended or Code shall expire by limitation and become null and void If the the date of such permit or if the building or work authorized by r a perid of 180 dars (Section 303W Uniform Buil in Cod DATE f7!12& t r"J APPLICANTS SIGNATURE WHIP: File YELLOW: Applicant PINK: Finance - c . CITY OF CARLSEAD % INSPECTION REQUEST PEi(MIT# CB941641 FOR 07/03/95 INSPECTOR AREA TP DESCRIPTION: 57300 SF OFFICE/MFG COBRA PLANCKY CB941641 TYPE: IT1 CONST . TYPE IIIN JOB ADDRESS: 1810 ASTON AV STE : /” LOT: APPLICANT: BLACKMORE PARKVIEW ASSOCIATES PHONE: 619 792-1212 OCC GRP E2 CONTRACTOR: RENO CONSTRUCTION OWNER: REMARKS: RS/STEVE/431-9788 SPECIAL INSTRUCT: PHONE: 619 462-7025/ PHONE : / INSPECTOR ,/d TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB940855 e ISSUED -~~ __ SE940058 SWOW ISSUED AS940077 ASC ISSUED FS940019 FIXSYS ISSUED SE940092 SWOW ISSUED AS950005 ASTI ISSUED AS950015 ASC ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical $ 49 ME Final Mechanical - -- - DATE 062795 062395 060695 060195 060195 060195 052595 052595 052595 052595 052295 052295 052295 050895 050895 050895 042795 042495 042495 042495 ***** INSPECTION HISTORY DESCRIPTION ACT INSP Final Combo CO TP Rough/Ducts/Dampers PI TP Rough Electric AP TP Frame/Steel/Bolting/Welding AP TP Rough Electric AP TP Rough/Ducts/Dampers AP TP Frame/Steel/Bolting/Welding PI TP Rough Electric PI TP Rough/Ducts/Dampers PI TP Rough Electric PA TP Frame/Steel/Bolting/Welding CO TP Rough Electric CO TP Rough/Ducts/Dampers CO TP Frame/Steel/Bolting/Welding AP TP Rough Electric AP TP Rough/Ducts/Dampers AP TP Interior Lath/Drywall AP TP Rough/Ducts/Dampers AP TP Frame/Steel/Bolting/Welding AP TP Rough Electric AP TP ***** COMMENTS SEE LIST/PARTIAL INSP SUB PANELS & TRANS T-BAR GRID 1ST FLR CEIL LITES 1ST FLR DCTS 1 FLR(DMPR REQ)@ STR COR T-BAR GRID (2 FLRS) CEILING LITES (2 FLRS) DUCTS/PLMNS (2 FLRS) SVC GEAR ONLY GRID CEILING LITES REGISTERS WALLS/CEIL ELECT RM CONDUIT ELEC RM AIR INTAKE ELEC RM RESTRMS RESTRM CEILING RESTRM CEILING RESTRM CEILING PEkMIT# CB941641 CITY OF CARLSBAD INSPECTION REQUEST FOR 07/03/95 DESCRIPTION: 57300 SF OFFICE/MFG COBRA TYPE: IT1 JOB ADDRESS: 1818 ASTON AV INSPECTOR AREA TP PLANCKY CB941641 OCC GRP B2 CONSTR. TYPE IIIN STE : LOT : ***** INSPECTION HISTORY ***** DATE DESCRIPTION 041995 Rough/Ducts/Dampers 041995 Interior Lath/Drywall 041995 Interior Lath/Drywall 041895 Rough/Topout 041895 Rough/Ducts/Dampers 041895 Interior Lath/Drywall 041795 Rough Electric 041495 Gas/Test/Repairs 041395 Frame/Steel/Bolting/Welding 041395 Rough/Topout 041395 Rough/Ducts/Dampers 041395 Gas/Test/Repairs 041295 Rough/Topout 041295 Rough Electric 041295 Gas/Test/Repairs 041295 Rough/Ducts/Dampers 041195 Frame/Steel/Bolting/Welding 041195 Rough/Topout 041195 Rough Electric 041095 Rough/Topout 041095 Rough Electric 040695 Interior Lath/Drywall 040595 Frame/Steel/Bolting/Welding 040595 Exterior Lath/Drywall ACT INSP NR TP PA TP AP TP AP TP NR TP PA TP CO TP CO TP PA TP AP TP PA TP CO TP NR TP PA TP CO TP PA TP PI TP NR TP PI TP PI TP PA TP PA TP NR PY NR PY COMMENTS MECH @ REST LIDS 2ND FLR OFFICES 2ND FLOOR OFFICE WATER LINES WALLS 1ST FLOOR, MFG AREA REST.EXH DUCTS 2ND FLR NO RESET OF CLOCK RESTROOMS DUCTS 2ND FLR FAILED TEST/NO RE-SET 2ND FLR OFFICES FAILED 24 HR TEST DUCTS 2ND FLR 2ND FLR OFFICES 2ND FLR OFFICES NOT COMPLETE OFFICE WAUS 1ST FLR N.SIDE ONE SIDE DMZ WAUS PERMIT# CB941641 CITY OF CARLSBAD INSPECTION REQUEST FOR 05/08/95 INSPECTOR AREA TP ~, DESCRIPTION: 57300 SF OFFICE/MFG COBRA TYPE: IT1 CONSTR. TYPE IIIN JOB ADDRESS: 1818 ASTON AV STE : APPLICANT: BLACKMORE PARKVIEW ASSOCIATES PHONE: 619 CONTRACTOR: RENO CONSTRUCTION PHONE: 619 462-702 OWNER: PHONE : PLANCKY CB941641 OCC GRP B2 REMARKS: RS/STEVE/431-9788 SPECIAL INSTRUCT: INSPECTOR L TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB940855 ISSUED 63940058 SWOW ISSUED AS940077 ASC ISSUED FS940019 FIXSYS ISSUED SE940092 SWOW ISSUED AS950005 ASTI ISSUED AS950015 ASC ISSUED CD LVL DESCRIPTION ACT COMMENTS IJL, 34 EL Rough Electric - &- @/h& RP crRM %- ./L/- wlvdu/r WAW. bid r/rJ/Zwr* ***** INSPECTION HISTORY ***** DATE DESCRIPTION 042795 Interior Lath/Drywall 042495 042495 042495 041995 041995 041995 041895 041895 041895 041795 041495 041395 041395 041395 041395 041295 041295 041295 041295 041195 041195 041195 Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Interior Lath/Drywall Rough/Topout Rough/Ducts/Dampers Interior Lath/Drywall Gas/Test/Repairs Frame/Steel/Bolting/Welding Rough/Topout Rough/Ducts/Dampers Gas/Test/Repairs Rough/Topout Rough Electric Gas/Test/Repairs Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough Electric Rough/Ducts/ Dampers ACT INSP AP TP AP TP AP TP AP TP NR TP PA TP AP TP AP TP NR TP PA TP CO TP CO TP PA TP AP TP PA TP CO TP NR TP PA TP CO TP PA TP PI TP NR TP PI TP COMMENTS RESTRMS RESTRM CEILING RESTRM CEILING RESTRM CEILING MECH @ REST LIDS 2ND FLR OFFICES 2ND FLOOR OFFICE WATER LINES WALLS 1ST FLOOR, MFG AREA REST.EXH DUCTS 2ND FLR NO RESET OF CLOCK RESTROOMS DUCTS 2ND FLR FAILeD TEST/NO RE-SET 2ND FLR OFFICES FAILED 24 HR TEST DUCTS 2ND FLR 2ND FLR OFFICES 2ND FLR OFFICES n CD LVL DtSCAIPTIOW Am C0-S PERMIT# CB941641 CITY OF CARLSBAD INSPECTION REQUEST FOR 04/24/95 INSPECTOR AREA TP ~. DESCRIPTION: 57300 SF OFFICE/HFG COBRA PLANCKt CB941641 TYPE: IT1 JOB ADDRESS: 1818 ASTON AV STE : OCC GRP B2 CONSTR. TYPE IIIN ' LOT: APPLICANT: BLACKKORE PARKVIEW ASSOCIATES PHONE: 619 792-1212 CONTRACTOR: RENO CONSTRUCTION PHONE: 619 462-7025 / OWNER: PHONE : / REMARKS: RS/STEVE/431-9788 SPECIAL INSTRUCT: INSPECTOR /J TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB940855 ISSUED SE940058 SWOW ISSUED AS940077 ASC ISSUED FS940019 FIXSYS ISSUED SE940092 SWOW ISSUED AS950005 ASTI ISSUED CD LVL DESCRIPTION ACT COMNENTS 43 NE AirCond/Purnace Set wee- e-- CCAW /4! Pe. LFL6-A AP - RcJi-.. /-(/L/L., ***** INSPECTION HISTORY ***** DATE 041995 041995 041895 041895 041895 041795 041495 041395 041395 041395 041395 041295 041295 041295 041295 041195 041195 041195 041095 041095 040695 040595 040595 DESCRIPTION Rough/ Ducts/Dampers Interior Lath/Drywall Rough/Topout Rough/Ducts/Dampers Interior Lath/Drywall Rough Electric Gas/Test/Repairs Frame/Steel/Bolting/Welding Rough/Topout Rough/Duct s/ Dampers Gas/Test/Repairs Rough/Topout Rough Electric Gas/Test/Repairm Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Topout Rough Electric Interior Lath/Drywall Frame/Steel/Bolting/Welding Exterior Lath/Drywall ACT INSP NR TP PA TP AP TP NR TP PA TP CO TP CO TP PA TP AP TP PA TP CO TP NR TP PA TP CO TP PA TP PI TP NR TP PI TP PI TP PA TP PA TP NR PY NR PY COMHENTS KECH @ REST LIDS 2ND FLR OFFICES WATER LINES WALLS 1ST FLOOR, HFG AREA REST.EXH DUCTS 2ND FLR NO RESET OF CLOCK RESTROOMS DUCTS 2ND FLR FAILED TEST/NO RE-SET 2ND FLR OFFICES FAILED 24 HR TEST DUCTS 2ND FLR 2ND FLR OFFICES 2ND FLR OFFICES NOT COMPLETE OFFICE WALLS 1ST FLR W.SIDE ONE SIDE DMZ WALLS CITY OF CARISBAD INSPECTION REQUEST PERnITY CB941641 FOR 04/20/95 INSPECTOR AREA TP DESCRIPTION: 57300 SF OFFICE/MFG COBRA PUINCK# CB941641 TYPE: IT1 STE: OCC C7.Z.E GRP E2 IIIN JOB ADDRESS: 1818 ASTON AV APPLICANT: BLACKMORE PARKVIEW ASSOCIATES PHONE: 619 792-1212 CONTRACTOR: RENO CONSTRUCTION PHONE: 619 462-702 OWNER: PHONE : , REMARKS: MW/STEVE/431-9788 SPECIAL INSTRUCT: INSPECTOR I TOTAL TIWE: --RELATED PERMITS-- PERMIT# TYPE STATUS CB940855 CON ISSUED SE940058 SWOW ISSUED AS940077 ASC ISSUED FS940019 FIXSYS ISSUED SE940092 SWOW ISSUED AS950005 ASTI ISSUED CD LVL DESCRIPTION ACT C0lMENTS 23 PL Gas/Test/Repairs 44 WE Rough/Ducts/Dampers -- - -- - ***** INSPECTION HISTORY ***** Da 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 rTE DESCRIPTION 1895 Rough/Topout 189 5 Rough/Ducts/Dampers 1895 Interior Lath/Drywall 1795 Rough Electric 1495 Gas/Test/Repaire 1395 Frame/Steel/Bolting/Welding 1395 Rough/Topout 1395 Rough/Ducts/Damperta 1395 Gas/Test/Repairs 1295 Rough/Topout 1295 Rough Electric 1295 Gas/Test/Repairs 1195 Frame/Steel/Bolting/Welding 1195 Rough/Topout 1195 Rough Electric 1095 Rough/Topout 1095 Rough Electric 0695 Interior Lath/Drywall 0595 Frame/Steel/Bolting/Welding 0595 Exterior Lath/Drywall 1295 Rough/Ducte/Dampers ACT INSP AP TP NR TP PA TP CO TP CO TP PA TP AP TP PA TP CO TP NR TP PA TP CQ TP PA TP PI TP NR TP PI TP PI TP PA TP PA TP NR PY NR PY COMMENTS WATER LINES WAUS 1ST FLOOR, WFG AREA REST.EXW DUCTS 2ND FLR NO RESET OF CLOCX RESTROOMS DUCTS 2ND FLR FAILED TEST/NO RE-SET 2ND FLR OFFICES FAILED 24 HR TEST DUCTS 2ND FLR 2ND FLR OFFICES 2ND FLR OFFICES NOT COMPLETE OFFICE WAUS 1ST FLR W.SIDE ONE SIDE DMZ WALL8 PERMIT# CB94 164 1 DESCRIPTION: 57300 SF TYPE: IT1 JOB ADDRESS : 1818 APPLICANT: BLACKMORE CITY OF CARLSBAD INSPECTION REQUEST FOR 04/19/95 INSPECTOR AREA TP OFFICE/WG COBRA PLANCKl CB941641 OCC GRP B2 CONSTR. TYPE IIIN ASTON AV STE : LOT: PARKVIEW ASSOCIATES PHONE: 619 792-1212 CONTRACTOR: RENO CONSTRUCTION OWNER: REMARKS : MW/ STEVE/ 4 3 1-97 88 SPECIAL INSTRUCT: PHONE: 619 462-7025 PHONE : INSPECTOR TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB940855 ISSUED 83940058 SWOW ISSUED CD LVL 17 ST 24 PL 34 EL AS940077 ASC ISSUED FS940019 FIXSYS ISSUED SE940092 SWOW ISSUED AS950005 ASTI ISSUED DESCRIPTION ACT COMMENTS Interior Lath/Drywall Rough/Topout Rough Electric ***** INSPECTION HISTORY ***** DATE DESCRIPTION 041795 041495 041395 041395 041395 041395 041295 041295 041295 041295 041195 041195 041195 041095 041095 040695 040595 040595 ~ough Eiectric Gas/Test/Repairs Frame/Steel/Bolting/Welding Rough/Topout Rough/ Ducts/Dampers GaS/TESt/RepairS Rough/Topout Rough Electric Gas/Test/Repairs Rough/ Ducts/Dampers Frame/steel/Bolting/Welding Rough/Topout Rough r1 ectric Rough/Topout Fough Flectric Interiqr Lath/Drywall Frame/~tcel/Bolting/Welding Fxtericr Lath/Drywall 1 ACT INSP CO TP CO TP PA TP AP TP PA TP CO TP NR TP PA TP CO TP PA TP PI TP NR TP PI TP PI TP PA TP PA TP NR PY NR PY COMMENTS REST.EXH DUCTS 2ND FLR NO RESET OF CLOCK RESTROOMS DUCTS 2ND FLR FAILED TEST/NO RE-SET 2ND FLR OFFICES FAILED 24 HR TEST DUCTS 2ND FLR 2ND FLR OFFICES 2ND FLR OFFICES NOT COMPLETE OFFICE WALLS 1ST FLR N.SIDE ONE SIDE DMZ WALLS CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB941641 FOR 04/18/95 DESCRIPTION: 57300 SF OFFICE/MFG COBRA TYPE: IT1 - - - - . - - - JOB ADDRESS: 1818 ASTON AV APPLICANT: BLACIMORE PARKVIEW ASSOCIATES PHONE: CONTRACTOR: RENO CONSTRUCTION PHONE : OWNER: PHONE : INSPECTOR AREA TP PLANCKX CB941641 OCC CONST GRP ZT’E B2 IIIN STE: 9 792-1212 9 462-7025 REMARKS: HW/STEVE/431-9780 SPECIAL INSTRUCT: INSPECTOR ,d TOTAL TIME: --RELATED PERMITS-- PERMIT$ TYPE STATUS CB940855 e ISSUED SE940058 SWOW ISSUED AS940077 ASC ISSUED FS940019 FIXSYS ISSUED SE940092 SWOW ISSUED AS950005 ASTI ISSUED CD LVL DESCRIPTION ACT COMMENTS 14 ST Frame/Steel/Bolting/Welding & WL 44 ME Rough/Ducts/Dampers 14 ST Frame/Steel/Bolting/Welding 24 PL Rough/Topout 34 EL Rough Electric 44 ME Rough/Ducts/Dampers 24 PL Rough/Topout E UN7z-b- 34 EL Rough Electric - /7- fl&&r*, #&JJ A&? , ***** INSPECTION HISTORY ***** DATE DESCRIPTION 041395 041395 041395 041395 041295 041295 041295 041295 041195 041195 041195 041095 041095 040695 040595 040595 Frame/Steel/Bolting/Welding Rough/Topout Rough/Ducts/Dampers Gas/Test/Repairs Rough/Topout Rough Electric Gas/Test/Repairs Rough/ Ducts/Dampers Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Topout Rough Electric Interior Lath/Drywall Frame/Steel/Bolting/Welding Exterior Lath/Drywall ACT INSP PA TP AP TP PA TP CO TP NR TP PA TP CO TP PA TP PI TP NR TP PI TP PI TP PA TP PA TP NR PY NR PY COMMENTS RESTROOMS DUCTS 2ND FLR FAILED TEST/NO RE-SET 2ND FLR OFFICES FAILED 24 HR TEST DUCTS 2ND FLR 2ND FLR OFFICES 2ND FLR OFFICES NOT COMPLETE OFFICE WALLS 1ST FLR N.SIDE ONE SIDE DMZ WALLS CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB941641 FOR 04/17/95 INSPECTOR AREA TP DESCRIPTION: 57300 SF OFFICE/MFG COBRA PLANCXX CB941641 TYPE: IT1 fl.2;: OCC GRP B2 IIIN JOB ADDRESS: 1818 ASTON AV STE : APPLICANT: BLACKMORE PARKVIEW ASSOCIATES PHONE: 619 792-121 CONTRACTOR: RENO CONSTRUCTION PHONE: 619 462-70 OWNER : PHONE : REMARKS: Mh'/STEVE/431-9788 SPECIAL INSTRUCT: INSPECTOR ,p-" TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB940855 ISSUED SE940058 SWOW ISSUED AS940077 ASC ISSUED FS940019 FIXSYS ISSUED SE940092 SWOW ISSUED AS950005 ASTI ISSUED CD LVL DESCRIPTION ACT C0MWWI"T 14 ST Frame/Steel/Bolting/Welding - 24 PL Rough/Topout - 34 EL Rough Electric - 44 ME Rough/Ducts/Dampers A2i-7S55"H-fh5Y zdi CZLL -- - ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 041395 Frame/Steel/Bolting/Welding PA TP RESTROOMS 041395 041395 041395 041295 041295 041295 041295 041195 041195 041195 041095 041095 040695 040595 040595 ~ Rough/Topout Rough/ Ducts/Dampers Gas/Test/Repairs ROUgh/TOpOut Rough Electric Gas/Test/Repairs Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Rough Electric Rough/Topout Rough Electric Interior Lath/Drywall Frame/Steel/Bolting/Welding Exterior Lath/Drywall ROugh/TOpOUt AP TP PA TP CO TP NR TP PA TP CO TP PA TP PI TP NR TP PI TP PI TP PA TP PA TP NR PY NR PY DUCTS 2ND FLR FAILED TEST/NO RE-SET 2ND FLR OFFICES FAILED 24 HR TEST DUCTS 2ND FLR 2ND FLR OFFICES 2ND FLR OFFICES NOT COMPLETE OFFICE WALLS 1ST FLR N.SIDE ONE SIDE DMZ WALLS TIWI ARRIVE: TIWI UAVE: CD LVL OtSCRIPTION Am COIQONTS CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB941641 FOR 04/13/95 INSPECTOR AREA TP DESCRIPTION: 57300 SF OFFICE/MFG COBRA PLANCK# CB941641 TYPE: IT1 CONS*., TYPE IIIN APPLICANT: BLACKMORE PARKVIEW ASSOCIATES PHONE: 619 792-1212 CONTRACTOR: RENO CONSTRUCTION PHONE: 619 462-702 OWNER : PHONE: OCC GRP B2 / JOB ADDRESS: 1818 ASTON AV STE : REMARKS: MW/STEVE/431-9788 SPECIAL INSTRUCT: INSPECTOR ,p TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB940855 ISSUED SE940058 SWOW ISSUED AS940077 ASC ISSUED FS940019 FIXSYS ISSUED SE940092 SWOW ISSUED AS950005 ASTI ISSUED CD LVL DESCRIPTION ACT COMMENTS 14 ST Frame/Steel/Bolting/Welding ,& A-&C~dOM< 24 PL Rough/Topout & 34 EL Rough Electric l&--, 44 ME Rough/Ducts/Dampers & 4uO-s ZhJL -- 23 - FCiz & F=1UO 7Zs7- IUA 1ZL-rr 7- ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COKMENTS 041195 Frame/Steel/Bolting/Welding PI TP 2ND FLR OFFICES 041195 Rough/Topout NR TP 041195 Rough Electric PI TP 2ND FLR OFFICES 04 1095 Rough/Topout PI TP NOT COMPLETE 041095 Rough Electric PA TP OFFICE WALLS 1ST FLR N.SIDE 040695 Interior Lath/Drywall PA TP ONE SIDE DMZ WALLS 040595 Frame/Steel/Bolting/Welding NR PY 040595 Exterior Lath/Drywall NR PY CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB941641 FOR 04/12/95 INSPECTOR AREA TP DESCRIPTION: 57300 SF OFFICE/MFG COBRA PLANCK# CB941641 TYPE: IT1 CONSTR. TYPE IIIN APPLICANT: BLACKMORE PARKVIEW ASSOCIATES PHONE: 619 792-1212 JOB ADDRESS: 1818 ASTON AV CONTRACTOR: RENO CONSTRUCTION OWNER: PHONE : OCC GRP B2 REMARKS: MW/STEVE/431-9788 SPECIAL INSTRUCT: INSPECTOR /Ld TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB940855 ISSUED SE940058 SWOW ISSUED AS940077 ASC ISSUED FS940019 FIXSYS ISSUED SE940092 SWOW ISSUED AS950005 ASTI ISSUED CD LVL DESCRIPTION ACT COMMENTS 24 PL Rough/Topout & 34 EL Rough Electric PA ZcCy~m=l~ 3L- *- -- - ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 041095 Rough/Topout PI TP NOT COMPLETE 041095 Rough Electric PA TP OFFICE WALIS 1ST FLR N.SIDE 040695 Interior Lath/Drywall PA TP ONE SIDE DMZ WALLS 040595 Frame/Steel/Bolting/Welding NR PY 040595 Exterior Lath/Drywall NR PY C10#562747 M ye rSo n DATE: 6-8-95 Electric Inc. TO: City Of Carlsbad Attn: Inspection Department Subject: Cobra Golf 1818 Aston Ave. Carlsbad Ca. To Whom It May Concern, The switchboard for the above project has been torque to the specifications of the manufacture. Sincerely, PMlcm 310 N. Andreasen Dr. Escondido, Ca. 92029 Phone (619) 746-9881 Fax 746-0610 ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: 1/31/95 JURISDICTION: Carlsbad PLAN CHECK NO.: 94-1641 PROJECT ADDRESS: 1818 Aston Ave. PROJECT NAME: SET XI a APPLICANT EJURISDICTIO% a PLANREVIEWER 0 FILE [XI The plans transmitted herewith have been correc ~Jd where necessaty and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 0 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 0 The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone #: REMARKS: INSPECTOR; Please check the existing building sewer, must be 6 inch for the demand and slope shown, (plan was changed from 4 inch to 6 inch.) q' By: GlenAdamek Enclosures: Esgil Corporation 1/31/95 0 GA 0 CM Ix] PC trnsmtl dot ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAW DIEGO, CA 92123 (619) 660-1468 DATE: JAN. 18, 1995 JURISDICTION: CARLSBAD PLAN CHECK NO.: 94-1641 PROJECT ADDRESS: 1818 ASTON AVE PROJECT NAME: T.I. SET I1 0 FILE The plans transmitted herewith have been corrected where necessaty and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: SMITH AIA, 5355 MlRA SORRENTO PL., #750, SD, CA 92121 [XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: 1 Telephone #: 0 REMARKS: By: ALI SADRE Enclosures: Esgil Corporation GA 0 CM IJ PC 1/11 lrnsmtl.dot CARLSBAD 94-1641 I1 JAN. 18, 1995 RECHECK PLAN CORRECTION LIST - = JURISDICTION: CARLSBAD PIAN CHECK NO.: 94-1641 PROJECT ADDRESS: 1818 ASTON AVE SET: I1 DATE PLAN RECEIVED BY ESGlL CORPORATION: 111 1 DATE RECHECK COMPLETED: JAN. 18, 1995 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: ESGlL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? OYes ONo CARLSBAD 94-1641 I1 JAN. 18, 1995 PLUMBING, MECHANICAL AND ENERGY CORRECTIONS JURISDICTION: Carlsbad DATE: 1/19/95 PLAN REVIEW NUMBER 94-1641 SET: I1 PLAN REVIEWER Glen Adamek 2. correct. Water lines are undersized per water line sizing data provided. Please a) For 6 psig per 100 feet maximum allowable pressure drop, the maximum demands for each pipe size are as follows: i) 1 /2 4 GPM 5FUtank OFU FV ii) 3/4” 7 GPM 9 FU tank 2 FU FV iii) 1” 14 GPM 20 FU tank 3 FU FV iv) 1-1/4 28 GPM 47 FU tank 11 FU FV v) 1-1/2” 43 GPM 95 FU tank 33 FU FV vi) 2” 80 GPM 280 FU tank 150 FU FV vii) 2-1/2” 135 GPM 555 FU tank 452 FU FV 3. Note to building inspector. Check the building sewer size must be larger than 4 inch for proposed total sewer load for less than 2% slope. Revised plan now shows 6 inch existing sewer, please check. 6. access is required to roof mounted equipment. 9. R-values, insulation thickness, and insulation locations. Clearly show the 8 jnch thick concrete (tilt-up) walls. IO. The eight gas unit heaters are not included in the energy design. The unit heaters are not on MECH-1 forms. (The MECH-2 forms show GF-1 through GF- 8 systems, but no GF- units shown on the mechanical plans? The GF- units shown on MECH-2 forms show the units are oversized, showing non-compliance Detail access and working clearances to HVAC equipment. Ladder Clearly show the wall and roof insulation as per the energy design. Show CARLSBAD 94-1641 I1 JAN. 18, 1995 to the energy standards.) Please correct. NOTE: Unit heaters do not provide an outside air (ventilation load) CFM. 15. 55,785 square feet, but the LTG-forms show the conditioned floor area to be only 27,759 square feet. why the BIG difference? Please correct. The ENV-1 and MECH-1 forms show the conditioned floor area to be Note: If you have any questions regarding this plan review list please contact Glen Adamek at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DATE: DEC. 22, 1994 JURISDICTION: CARLSBAD PLAN CHECK NO.: 94-1641 ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 SET I 0 FILE PROJECT ADDRESS: 1818 ASTON AVE PROJECT NAME: T.I. 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [XI The applicant's copy of the check list has been sent to: SMITH AIA, 5355 MlRA SORRENTO PL., # 750, SD, CA.92121 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: 1 Telephone #: REMARKS: By: ALI SADRE Enclosures: Esgil Corporation GA CM PC 12/15 trnsmtl.dot CARLSBAD 94-1641 DEC. 22,1994 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS OCCUPANCY: B2 USE: OFF/PROD TYPE OF CONSTRUCTION: IIIN ALLOWABLE FLOOR AREA: NO CHNG STORIES: 2 ACTUAL AREA: 25,000 HEIGHT: NO CHNG SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 12/12 OCCUPANT LOAD: 250 DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/15 11 DATE INITIAL PLAN REVIEW PLAN REVIEWER: ALI SADRE COMPLETED: DEC. 22,1994 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1991 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck p rocess. p lease note on t his list for a copy! where e ach correction item has been addressed. Le.. plan sheet number. spec ification sect ion. etc. Be sure to enclose t he marked up list when vou s ubmit the rev ised plans. LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1991UBC) lifonv.do1 1. 2. 3. 4. 5. 6. 7. 8. 9. IO. CARLSBAD 94-1641 DEC. 22,1994 Please make all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468. Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 302. Specify the floor area of improved space on both floors. Specify the occupant load of the improved space on plans. Provide a note on the plans indicating if any hazardous materials will be stored andlor used within the building which exceed the quantities listed in UBC Tables 9-A and 9-B. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1991 UBC, UMC and UPC and 1990 NEC. Note on plan that suspended ceilings shall comply with UBC Tables 47-A and 23-P. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge". In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS. This signage is only allowed at the mah exit. Section 3304(c). Provide a note on the plans stating "Penetrations of fire-resistive walls, floor-- ceilings and roof-ceilings shall be protected as required in UBC Sections 4304 and 4305. Specify the glazing in all offices on second floor, adjacent to doors. 11. on plans. i.e. handrail diameter, extension, etc. 12. Correct the discrepancies on the plans between the HC notes and details shown Note on the plans that new water closets and associated flushometer valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2, and urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard AI 12.19.2. H & S Code, Section 17921.3(b). .. CARLSBAD 94-1641 DEC. 22,1994 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6). No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official. (City Policy) All roof-mounted equipment shall be concealed from view. Provide structural detailing for the screening. Specify if the elevator is existing. Label one hour doors for it with S/D outside the elevator lobby. Show one hour doors typical for one hour stairs. Provide a note stating all one hour assembly penetrations will be “T” rated. Provide a second source of power for exit signs. Describe the function of the labs on plans. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 23. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE at Esgil Corporation. Thank you. PLUMBING, MECHANICAL AND ENERGY CORRECTIONS JURISDICTION: Carlsbad DATE: 12/21/94 PLAN REVIEW NUMBER 94-1641 SET: I CARLSBAD 94-1641 DEC. 22, 1994 PLAN REVIEWER: Glen Adamek 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Provide gas line plans and calculations, showing pipe sizes, pipe lengths, gas pressures, and gas demands. UPC Section 1219. Provide a table of maximum fixture units (and flow rates) permitted on each water line pipe size. Show 1/4“ per 12 slope on drain and waste lines. UPC Section 407. If the existing 4 inch building sewer is less than 1/4 per 12” slope it will be under sized . Fuel burning water heater shall not be installed in a bathroom, or in a closet or other confined space opening into bathroom. UPC, Section 1309. Correct the design at room # 130 men’s room. The plumbing plans seem to be incomplete. Please provide complete plumbing plans. Detail access and working clearances to HVAC equipment. Ladder access is required to roof mounted equipment. Detail disposal of main condensate drainage from air conditioning units. (UMC Section 51 0) Provide smoke detection in supply and return air ducts for required automatic shut-off controls as per UMC, Section 1009. Clearly show the wall and roof insulation as per the energy design. Show R- values, insulation thickness, and insulation locations. Clearly show the 8 inch thick concrete (tilt-up) walls. The eight gas unit heaters are not included in the energy design. Please correct. Plans show AC-12 and AC-14 ducts capped for future use, but MECH-4 form shows required ventilation from AC-12 and AC-14. Please correct. Please complete the required data on MECH-3 form, not provided on the schedules on sheet MI. (Allowed Rated Efficiencies) The MECH-2 form for AC-2 is not in the energy design. Please correct. The MECH-2 form for AC-3 is incomplete, and the installed unit is oversized. The production area lighting is not shown on the LTG- forms. Please correct. .. CARLSBAD 94-1641 DEC. 22,1994 16. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 1 3 1 (d). Show the daylit areas and required daylit area lighting controls for lighting in daylit areas. Title 24, Part 6, Section 131 (c). Correct room # 202 (open office) lighting controls. 17. Note: If you have any questions regarding this plan review list please contact Glen Adamek at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. ELECTRICAL PLAN REVIEW JURISDICTION: Carlsbad DATE: 12/22/94 PLAN REVIEW NUMBER :94-1641 I PLAN REVIEWER :Chuck Mendenhall 1. Note on the plans that circuit breakers used in the subpanels will be listed for combination with the current limiting main fuses or circuit breakers. 2. Specify the I‘ nearest electrode” used for each transformer secondary ground system (Le., building steel, cold water pipe). NEC 250-26(c). 3. Specify the dimensions of equipment rated 1200 amps or more. NEC 110-16(c). 4. Provide the required access and entrance to working space for equipment rated 1200 amps or more and over 6 feet wide. NEC 110-16(c). 5. Provide required transformer ventilation. NEC 450-9 6. Provide receptacle(s) within 25 feet of HVAC equipment. UMC 509. 7. Note on the single line diagram that the service GFP will be tested per San Diego Area Newsletter 230-95 8. The secondary grounds for the 75KVA transformers are undersized. The ground conductor must be #4 CU for the 3/0 secondary feeeders 9. Show on the plans the location of the 3OKVA transformer. It must be located in an area that will provide sufficient ventilation. CARLSBAD 94-1641 DEC. 22,1994 Note: If you have any questions regarding this electrical plan review list please contact the plan reviewer listed above at (619) 560-1468. To speed the review process, note on this list ( or a copy) where the corrected items have been addressed on the plans. CARLSBAD 94-1641 DEC. 22,1994 VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PLAN CHECK NO.: 94-1641 PREPARED BY: ALI SADRE BUILDING ADDRESS: 1818 ASTON AVE BUILDING OCCUPANCY: B2 DATE: DEC. 22, 1994 TYPE OF CONSTRUCTION: IIIN Air Conditioning Fire Sprinklers TOTAL VALUE Building Permit Fee: Plan Check Fee: Comments: $ 2,489.50 $ 1,618.18 Sheet 1 of 1 valuefee.dot . APPROVAL me item you have submitted tor rwiew has been approved. me approval is based on plans, informatb and/or specWions provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this oftice to insure continued WntOImance with applicable codes. Please review carefully all wmmenta altached, 85 failure to comply with iIIS1mctions in thls report can resuit in suspension of permit to build. 0 A Right-of-way permit is required prior to con~lruction of the following improvements: 9F-/6 q/ BUILDING PLANCHECK CHECKLIST PLANCHECK NO. CB / DATE: BUILDING ADdRESS: //// A5l;LpJ Ave PROJECT DESCRIPTION: 7& d%hZ /f6m a -,f??dD&fi' ddA#%, - 3P6sP I' mq PG-0 DENIAL Plesse see ths Bttached report d deficiencies marked with Make rwceswy wrrectio~ to plans or specwations for compliance with applicable codes and standards. Submit corrected plans and/or specifiions to this mce for review. By: Date: By: Date: By: Date: EST. VALUI .- ASSESSORS PARCEL NUMBER: AlTACHMENTS ENGINEERING DEPT. CONTACT PERSON 0 Dedication AppllCatlOn 0 Dedication Checklist 0 improvM ~ppiication 0 improvement Checklkt Future Improvement Agreement 0 Grading Permit Application 0 Grading Submittal Checklist Right of Way Permit Application 0 AigM d Way Permit Submittal Checklist 0 Sewer FW information sheet and intormation Sheet NAME Cny d carlsbad ADDRESS: 2075 Las Palmas Dr.. Carisbad. CA 92009 PHONE : (619) 4381161. Ekt. A4 P\WCS\CHKLSlWP0001 .FRY REVWIIB4 2075 Las Paimas Dr. - Carisbad, CA 92009-1576 - (619) 438-1161 FAX (619) 438-0894 BUILDING PIANCHECK CHECKLIST SITE PIAN l+wL dJ 3rdJ 0 0 1. Provide a fully dimensioned site plan drawn to scale. Show: A. NorthArrow D. Property Lines Easements B. Existing & Proposed Structures E. Easements C. Existing Street Improvements F. Right-of-way Width 8 Adjacent Streets 0 2. Show onsite plan: A. Drainage Patterns C. Existing Topography B. Existing & Proposed Slopes / do 0 3. Include note: "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line (whichever is less).' [Per 1985 UBC 2907(d)5]. On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent' (per 1990 UBC 2907(d)5.). dm 4. Include on title sheet A. Sie address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. MISTING PERMIT NUMBER DESCRIPTION Pageld4 REV Wll/S4 BUILDING PIANCHECK CHECKLIST DISCRETIONA RY APPROVAL COMPLIANCE 0 0 5. Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by: Date: DEDICATION REQUIREMENTS 6. 0 0 Dedication for all street Rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding 8 -pursuant to Code Section 18.40.030. Dedication required as follows: Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by Date: IMPROVEMENT REQU IREMEN= 0 0 7a. Ail needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ pursuant to Code Section 18.40.040. Public improvements required as foliows: Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Improvement Plans signed by: Date: Page2of4 REV OUllM BUILDING PLANCHECK CHECKLIST MISCELLANFOUS PE RMln 9. A RIGHT-OF-WAY PERMIT is required to do work in Ci Right-of-way and/or private work adjacent to the public Right-of-way. Types of work include, but are not limited to: street improvements, trees, driveways, tieing into public storm drain, sewer and water utilities. Right-of-way permit required for 0 0 A separate Right-of-way permit issued by the Engineering Department is required for the following: )$ 0 0 $r: 0 0 IO. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. 11. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for Ci approval prior to issuance of a 3 Permit. Industrial waste permit accepted by: 6 /“3.&$&.- /v Pe9e4014 REVW1101 EMGiNEERlNG DEPARTMENT ENGiNEERlNG REVIEW SECTION FEE CALCULATION WORKSHEET 0Ermmrp.bruedonunconnmlndomuplonlhom~ Address: // /#NA//A c& e& Puml Na ,ff+ 6f/ Jq -U- lxaad on auldlq plMcllw prrn submmcll Pm by: Dam: <$$& ch.ckdby: 0.a: I I EDU CALCULATIONS: LiaI typr md sqwn ta ai uu FEES REOUIREO: / FEES R EQUIREP; PUBUC FACILITIES FEE REQUIRED YES 0 NO (SO@ Bulldl~~~ DepMmern tor amoUnt) WrmlN CFD: YES (no Mdg. 6 thoroughfare fun, 0 NO 'w reducd Traffic Imprr* Fee) fr 1 ~fil.P*RK-INIIEU FEE PARK AREA: FEWNIT: X NO.UNITS: 2.TRAFFIC IMPACT FEE mrr: a7 x FEUADT: 22 3. BRIDQE AND THOROUQHFARE FEE mrs: X FEWAD1 ZONE 5 4 x4. FACILITIES MANAQEMENT FEE S(2.Fr.: 57300 X FE€/SQ.Fr.: 40t .3f - 1. 1,2,3 Number in Circle indicates plancheck number where d&ciency was identified (Name) APN: 2\2-\‘20 c Type of Project and Use CFDCiOut) # TZ-. Zone cfi Facilities Management Zone !5-- DATE OF COMPLETION: Compliance with conditions of approval? [f not, state conditions which require action. Conditions of Approval APPROVAVRESO. NO. DATE: PROJECT NO. OTHER RELATED CASES: Compliance with conditionr of approd? ff not, sate conditio^ which quire action. Conditions of Appmd &a calihlu ~CorrtJCamrmrrwm .. PamitRcqrtirrd:YES-NO- / DATE OF APPROVAL Sa Dicgo Coast Compliance with conditiom of approval? If not, state condihom which require action. conditions of Appd 3111 Cmho Del Rio North, Suite 200, S.n Diego, CA. 92108-1725 (619) 521-8036 [7 c] wusioq Housing Fee mqukd: YES - NO - / (Effecuve date of Inclusionary Housing Ordinance - May 21, 1993.) Site Plm: 1. 2. 1. 2. 3. 4. Provide a Cuuy dimensioned site plan drawn to scale. Show: No* MOW, propeny lines. easements, existing and proposed structures, sueeu. existing street improvements. right-of-way width, dimensioned setbacks and exisring topographical lines. Provide legal description of property, and assessor's parcel number. Setback: Front: Rquired Shown Int. Side: Required Shown Shown Shown Street Side: RtqM Rear: Required Lor coverage: ReqM Shown Hcight: Rcsrrircd - Shown Guest Spaces Required - Shown Parking: spaces Required 1x Shown 2Qr OK TO ISSUE AND ENTEREO APPROVAL INTO COMPUTER yw" DATE c:ll;.kr PLNCICFRM . . ity of Carlsbad 94302 Fire Department Bureau of Prevention General Comments: Date of Report: Tuesday, March 7,1995 Contact Name Law Kloha Address 5355 Mira Sonento PI Ste 750 City, state San Diego CA 92121 Bug. Dept. No. 94-1641 Job Name Blackmore Job Address 1818 *Ston Planning No. Ste. or Bldg. No. Additional information needed on the technical report prior to building final. 2560 Orion Way Carlsbad, California 92008 (619) 931-2121 94302 Fire Department . Bureau of Prevention Citv o f Ca rlsbad Plan Review: Requirements Category: Building Pian Check Date of Report: Tuesday, March 7,1995 Contact Name Larry Kloha Reviewed by: (? . ~cK..€& Address 5355 Mira Somento PI Ste 750 City, State Sari Diego CA 92121 Bldg. Dept. No. 94-1641 Planning No. Job Name BkCkmore Job Address 1818 Aston Ste. or Bldg. No. Approved - The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. 0 Disapproved - Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st 2nd 3rd CFDJoMI 94302 File# Other Agency ID 2560 Orion Way Carisbad, California 92008 (619) 931-2121 . ity of Carlsbad 94302 Fire Department Bureau of Prevention General Comments: Date of Report: Wednesday. December 21,1994 Contact Name Lany Kloha Address 5355 Mira Sorrenlo PI Ste 750 City, State Bug. Dept. No. 94-1641 JobName Bladtmore Job Address 1818 Aston San Diego CA 92121 Planning No. Ste. or Bldg. No. DISAPPROVED Please submit three sets of corrected plans to the Building Dept. for routing to the appropriate departments. 2560 Orion Way Carlsbad, Caiifornla 92008 (619) 931-2121 .. Requirements Category: Building Pian Check HAF9-450 2 4 Deficiency Item: Pen d I n g 11 Knox Box Knox Box required when access lo or within a structure or an area is unduly dHiicuH because of secured openings or where immediate access is necessary for life saving or fire-fighting purposes. The Fire Dept. will determine the location for the key box and provide an authorized order form. Deficiency Item: Pen d I n g 14 Provide Technical Report The building official may require a technical opinion and report to Identify and develop methods of omtection from the hazards Dresented bv the hazardous materials. The opinion and r~pOtl shall be r - -- prepared by a qualified persbn, firm or &lporation approved by the buikling official and shall be provided without charge to the enforcing agency. The opinion and report may include, but is not limited to, the preparation of a hazardous material management plan (HMMP): chemical analysis: recommendations for methods of isolation, separation, containment or protection of hazardous materials or pmesses. The technical report shall contain a listing of quantities and classification of all hazardous materials which will be stored, dispensed, handled, or used on the premises. Deficiency Mem: Pen d I n g 24 Special Egress Control Devices When approved by the building official. exit doors in Group B, Division 2 Occupancies may be equipped with approved listed special egress-control devices of the time-delay type, provided the building is protected throughout by an approved automatic sprinkler system and an approved automatic smoke-detection system. Such devices shall conform lo all of the conditions stated in UBC 3304(e). Page 2 12/21/94 INDUSTRIAL WASTE DISCHARGE PERMIT APPLICATION BUSINESS NAME ~&&Q.A &I LC SITE ADDRESS I5 I 6 b5-m~ CA~L~~AD, CA 42008 CONTACT PERSON (at business) PAT k Dou GALL PHONE NUMBER 7 Type of Business (check all that apply) pricuitural - 0 Government 0 Photo Lab sembly . Laboratory Retail 0 Chemical Handling ' manufacturing 0 Warehouse Electronics 0 Other 0 Food Automotive 0 Laundry Service Station DESCRIBE WASTE OTHER THAN DOMESTIC (Chemicals, Particulates, etc.) NOrJ E ... ~~ GENERAL DESCRIPTION OF ONSITE WASTEWATER PROCESSING: (chemical & physical characteristics)- Is business presentty in operation at site? 0 YES @NO Has Wastewater Discharge Permit been applied for through the Encina Water Authority? ayES 0 NO .Applicant's Name h#@V w Titie hFbt Phone e 2- 3 88 OWN& Piease Print Date -7-45- Date forwarded to Encina Hazardous Materials state ZP Mailing Address 9aaOe Site Address City State Zip Idla ak &. L, fAk Plan File# Plan FiieX I I PART I: FIRE DEPARTMENT. HAZARDOUS MATERIALS MANAGEMENT DIVISION: OCCUPANCY CLASSIFICATION Indicate by circling the item. whether your business wiil use, process, or store any of the following hazardous materiels. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. PART II: COUNN OF SAN DIEGO HEALTH DEPARTMENT ~ HAZARDOUS MATERIALS MANAGEMENT DIVISION: CONTINGENCY PLAN REVIEW: If the answer IO any of tha questions is yes. applicant must contact the County of San Diego Hazsrdous Materials Managamem building permit. FEES MAY BE REQUIRED Division. 1255 Imperial Avenue. 3rd floor. San Oisgo, CA 92186-5261. Telephone 16191 338-2222 prior to the issuance of e "-- LI" OFFICE USE ONL: 0 RMPP Exempt I Date Initials RMPP Required ,-- 1. c] 2.s 0 Will your businesa dispose of Hazardour Subs tanoer or Medical Waste in any amount7 Is your business listed on the reverse side of this form7 Will your business stwe or handle Hazardous Substenoer in quantities equal to or greater than 55 gallons, SO0 pounds, 200 cubic feet or carcinogenalraproduotiva toxins in any quantity? 4. u ill your business use an existing or inrtnll en underground storage tank? 5.0 ill your business store or handle Acutely Hazardous Materiels7 PART til: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions is yes, applicant must contact the Air Pollution Control District, 91 50 Chesapeake Drive. San Diego, CA 92123 Telephone (6191 694-3307 prior to the issuance of a building permit. 1, c] WWiIl the intended occupant Install or use any of the aquipment listed on the Listing of Air Pollution Control District Permit Cetepories. on tht reverse side of this form? 2.0 0 (ANSWER ONLY IF QUESTION 1 IS YES.) Will the subject facility be located within 1,000 feet of the outer boundary of e school IK througi 121 as listed in the current Directory of School and Community Coliegb Oistrictr. published by the San Diego County Office of Education en,: the current California Private School Directory. compiled in accordance with provisions of Education Coda Section 331907 YES NO FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: Oy: Date: 4 Date RMPP Completrc Date Initials I EXEMPT FROM PERMlT REQUIREMENTS 0 PERMIT BUT NOT OCCUPANCY ~ ~~~ bnvimMicoW Hullh Ssrvim ...~ TITLE 24 DOCUMENTATION FOR COBRA GOLF WALSH ENGINEERS REVISED 1/26/95 PAUL HAUSBECK 8840 Complex Drive, Suite 205 - San Diego, California 92123 * (619) 541-0788 - FAX (619) 541-0787