HomeMy WebLinkAbout1818 ASTON AVE; ; CB960129; PermitBUILDING PERMIT Permit No: CB960129
ii:/15/96 12: 51 Project No: A9502719
Paqe 1 of 1 Development No:
Job Address: 1818 ASTON AV Suite:
?errnit Type: INDUSTRIAL TENANT IMPROVEMENT F3rcel No: 212-120-06-00 Lot#:
Valuation: 0 Construction Type: NEW
Occupancy Group:
Description: AWNINGS FOR EXISTING COLUMS Applied: 01/23/96
: SEE PERMIT -93-1859 Apr/Issue: 02/15/96
I
Reference#: Status: ISSUED
Entered By: RMA
Appl/Ownr : SMITH CONSULTING ARCHITECTS 619-452-3188
5355 MIRA SORRENTO PL, #750
LA MESA,
Fees Required ________-____________
Fees :
Adjustments:
Total Fees:
,edits ***
.OO
.00
.00
CITY OF CARLSBAD
2075 Lss wlmas Jh., Carlsbd, CA Cnoos (619) 438-1161
PERMlT APPLICATlON
City of Carlsbad Building DeparrPnt 2075 La5 Palms Dr., Carlobad, U 92009 (619) 438-1161
M\~L-
From kt I (see back) give code of Permit-m: MI 5 L. .........................................................
For Residential Pmiects Only: From List 2 (see back) give
Code of Structure-Type:
Net WGain of Dwelling Units
2 PRCIE€TUiFORMATlON
PLAN CHECK NO. p- \.z9
FOR OFFICE USE ONLY ~ ~~ ~~~~~~~
Building or Suite No. \%It3 P %N he. Address
Nearest Cross Street 0
Phase No. f?,~
NAME (last name first) ADDRESS
CITY
I%. & 750
ZIP CODE Yz\>l DAY TELEPHONE [b\q ) & 2- 31 8 e3 STATE
ADDRESS 1812 knN '&E.
NAME (last name first)
CITY l!AMEf-%r STATE ZIP CODE 5 lq 44- DAY TELEPHONE ) &, % 70 2 5-
STATE LIC. # LICENSE CLASS CITY BUSINESS LIC. #
-E (last name tint) SM I 'W f&Jkll%ld6 b- 5 pL-if2w.r CITY STATE ZIP CODE DAY TELEPHONE STATE LIC. # cl I -2 0 I
Workers' Compensation Uedaratmn: I hereby attlrm thai 1 have a cemticate ot consent to selt-insure issued by the Vlrector at lnaustnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insure:, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY WLICY NO. FXF'IRATlON DATE
Cemticate of exemptmn: 1 certlty that In the pertormance ot the work tor Which this permit IS Issued. I Shall not employ any person In any manner
Y) as to become subject to the Workers' Compensation Laws of California.
SIGNATURE DATE
Uwner-nurlder UeClaration: I hereby attirm that 1 am exempt trom the contractors ucense law for the rollowing reason:
I, as owner of the properry or my employees with wages as their sale compensation, m'll do the work and the strucNre iS not intended or offered for sale (Sec. 7044, Business and Professions Code: The Cantractor's license law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.).
I, asowner of the property, am exclusivelycantracting with licensed ContractorS toconstruct the project (Sec. 7044, Businessand Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License law).
I am exempt under Section
0
0
0 Business and Profwians Code for this reason:
(Sec. 7031 5 Businm and Professions Code: Any City or County which requirn a permit to construct, alter, imprtrve, demolish, or repair
any slwcture, prior to its isuance, also requires the applicant for such pcrmir 10 file 3 sign4 sratement that he is licmwd pursuant to the orovisionr of the Cantractor's Licrncc law IChauter 9. commmcinx wiih Section 7000 of Division 3 of ihe Burins and Pmfrrcions thlel ~~~ ~ ~~~~~~~~~~~~~~~ ~~~~ _~~~, ,~~~ -, ~~ ~~ ~~~ ~~ ~~~ ~~~~~~~~~~~~ ~ ~~~ br that he is exempt therefrom, and the basis for the alleged exehption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001).
SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration farm or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act7
Is the applicant or future building occupant required to obtain a permit from the air pollution control distlict or air quality management district?
Is the facilify to be constructed within 1,OOO feet of the outer boundary of a school site?
IF ANY OF THE ANSWERS ARE YFS, A FINAL CERTIFICATE OF OOCUPANCY MAY NUT BE IssuFa -JULY 1.1989 UNLFSS "€E AFTLlC4NT HAS MET OR 1s mG THE REQ- OF 'ME OFFICE OF EMERGENCY SF.RWCES AND THE AIR HIUWION CONTROL DLSIRICX.
1 hereby atklm that there 15 a CONtrUCUOn lending agency tor the pertormance ot the work tor Whlch this permit IS mued (Sec JOY7( 11 civll Code].
0 YES 0 NO
0 YES 0 NO
DYES 0 NO
LENDER'S NAMR LENllER'S ADnRESS . .. . - . - - . . . .__. . .. ._ . . .
I crnity Ihat I have ma the applicauon and slate thal the above mlormarion is correct. 1 agree to comply with all City nrainmces and xair law8 relaring to building construction. I hereby authoriv represenlarives of the City of Carlrbad to enter upon the above menrioned propeny for inrpcnon purposes. I AIS0 AGREE TO SAVE INDFW AND KFW HARMlJlSS IlIE CTIY OF CAMSBAD AGAINST AIL LLABWllIFs. JUIX;MFWE, Oosrs AND FXPKNSU WlUWl MAY IN ANY WAY MXRUE A(;AlNSI'sAII) CITY IN CUNSWUWCR OF 'THE CRA"G OF llILS PF'MIT.
CXXW An OSHA permit is required far excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
Code shall expire by limitation and kome null and wid if the the date of such prmit or if the building or work authorized by r a period of 180 day (Section 303(d) Uniform
CS
DATE:
WHl/E File YELLOW Applicant PINK: Finance
- Status: FINAL
Dates: Applied : 122195 Apr/Issue : 011896
Completed : 071196 Expired : 010797 -
Job Title: CONCRETE COLUMS ONLY Valuation: 5,000 Descr: AWNINGS ON SEPERATE PERMIT
Tme Const: NEW Altkey : -- Address: 1818 Street: ASTON AV
Lot#: - Suite: Parcel: 2121200600 Owner: COBRA-BLACKMORE - - Occupancy: Reference#: - No district keyword
Appl/Ownr : SMITH CONSULTING ARCHITECTS Telephone: 619-452-3188 Address: 5355 MIRA SORRENTO PL, #750
LA MESA, CA 92121 Insp Area: PD Entered By: RMA
INSP: YES APPR: corn: MULTP: = MULTA: $ BAL: NO- ................................................................................
Project: A9502719 105 SF CANVAS AWNING.2 CONCRTE Entered: 12/21/95 By: COUNTER
EsGll Corporatlon
Trofessional Thn Keuicw Eyinccrs
DATE: February 9,1996
JURISDICTION: Carlsbad
PLAN CHECK NO.: 96-129
PROJECT ADDRESS: 1818 Aston Ave.
PROJECT NAME: Awning Addition Cobra Golf
SET XI
0 FIRE
0 FILE
c] The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's *********** codes.
[XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
0 The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
[7 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
0 The applicant's copy of the check list has been sent to:
[XI Esgil Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by: ) Telephone #:
REMARKS: On page 9, either change the "epoxy" anchor to expansion anchors (as shown on
page 6), or specify the IC60 #for the epoxy anchors (and the need for special inspection).
By: Kurt Culver Enclosures:
Esgil Corporation 0 GA 0 CM 0 GP 0 PC 2/6/96 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 (619) 560-1468 Fax (619) 560-1576
EsGil Corporation
!??ofcssionnf !Wan Review Engineers
DATE: February 1, 1996
JURI SD I CTI 0 N : Carlsbad
PLAN CHECK NO.: 96-129
PROJECT ADDRESS: 1818 Aston Ave.
SET I
0 FIRE
0 PLANREVIEWER
0 FILE
PROJECT NAME: Awning Addition Cobra Golf
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's *********** codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's ********** codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
[XI The applicant's copy of the check list has been sent to:
Smith Consulting 5355 Mira Sorrento PI. # 750
San Diego 92121
[XI Esgil Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by: ) Telephone #:
[XI REMARKS: This awning was originally included with Plan Check # 95-1859 (subsequently
removed from that permit). This plan now completes the construction originally desired.
No additional Esgil fees are due.
By: Kurt Culver Enclosures:
Esgil Corporation
[7 GA [7 CM GP [7 PC 1/25/96 trnsrntl.dot
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (619) 560-1468 Fax (619) 560-1576
-
Carlsbad 96- 129
February 1, 1996
GENERAL PLAN CORRECTION LIST
PROJECT ADDRESS: 1818 Aston Ave.
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 1/25/96 February 1, 1996
DATE REVIEW COMPLETED:
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
1. Please make all corrections on the original tracings and submit two new sets of prints to:
ESGIL CORPORATION.
2. To facilitate rechecking, please identify, next to each item, the sheet of the plans
upon which each correction on this sheet has been made and return this sheet
with the revised plans.
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
where they are located on the plans. Have changes been made not resulting from this
list?
3.
0 Yes 0 No
4.
5.
Provide the basis of approval for the awning’s fabric.
For the New Window Awnings (fifth page of the package submitted), detail the “upper”
and “lower” connections.
6. For the Detail A connection on the sixth page of the package submitted, specify the
manufacturer’s name and ICBO #for the expansion anchors.
- ...
Carlsbad 96-129
February 1, 1996
7. Clearly show on the plans the required edgelend distance requirements for the
expansion anchors, as specified in the ICBO report.
8. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 6191560-1468, to
perform the plan review for your project. If you have any questions regarding these plan
review items, please contact Kurt Culver at Esgil Corporation. Thank you.
PLANNING/ENGINEERlNG APPROVALS
' PERMIT NUMBER SE 9 6 o/a 7 DATE d -/- 96
ADDRESS /I /f 9&
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITION MINOR
( < J 10,000.00)
PLAZA CAMINO REAL
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER 0- U
PLANNER DATE
Rw 1 111 5/90
PIAHNINGmaaarsr -d
plan ch~dr NO. ?6-/2? ~b /9/8 AY~, & .
Planner DAVID RICK Phone 438-1161 en. 4328
I
(Name)
APN: -212- 120 05
Type of Projecr and Use ihd d4X - 65-Crf.
zone G Faciliaa Ma&ement Zone f m(w& # 0 properry m, complete SPECIAL TAX CALCULATION e-- uv. crrcie ... WORKSHEET provided by Building Department.) ooa qlI Pb u
@I Item Complete cas
Item [ncomplete - Needs your action
I,?, 3 Number in circle indicates plancheck number where deficiency was
identified
@ ‘iH ESS -a- &&&
/ &a Emrirolrmcn UlRNim- YES-NO- lYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not. State conditioru which rquire action. Conditions of Approval
,
APPROVWRESO. NO. DATE: PROJEm NO. OTHER RUATED CASES:
Compliance with coodidoa, of appmnl? If not, state conditioos which requke action. Conditions d Approval
EA cplifamrr ‘coadco ’ Pamit-YES-NO- /
DATE OF APPROVAL:
Saa Mego Cour Mmict, 3111 clmino Del Rio North, Suite 200, Sa Mego, CCL 92108-1725
Compliance wirh- conditioos of appmnl? If not, state conditioos which require action.
(619) 521-8036
conditions of Appmnl
~~o~ryHousingFeerrgrdrcd: YES-
Site Ph
(EHecrive date of Inclusionary Housing
1.
2.
zoning
1.
2.
3.
4.
Provide a fully dimensioned site plan drawn to scale. Show: Nod
arrow, properry lines, easements, exisring and proposed saucrures,
streets, existing sueet improvements, right-of-way width, dimensioned setbacks and existing topographical lines.
Provide legal description of propeny, and assessor's parcel number.
Setbacks:
Front: Rquired Shown -
[nt. Side: Required Shown -
Rear: Required
Lot coverage: Rquired Shown -
Shown - Shown Street Side: Reqw
Height: Rcsukcd - Shown
Parking: Spaces Required - Shown
Guest Spaces Required - Shown -
Additional Comments
n-
PLNCKFRM
95305
Bureau of Prevention
City of Carlsbad
Fire Department
Plan Review: Requirements Category: Building Plan Check
Date of Report: Thursday, January 25,1996 Reviewed by: U Contact Name Dennie Smlth
Address 5355 Mira Sorrento PI Ste 750
City, State San Diego CA 92121
Bldg. Dept. No. 96-129
Job Name CobraGolf
Planning No.
Job Address 1812 Aston Ste. or Bldg. No.
Approved - The item you have submitted for review has been approved. The approval is
based on plans; information and/or specifications provided in your submittal;
therefore any changes to these items after this date, including field modifica-
tions, must be reviewed by this office to insure continued conformance with
applicable codes. Please review carefully all comments attached, as failure
to comply with instructions in this report can result in suspension of permit to
construct or install improvements.
Disapproved - Please see the attached report of deficiencies. Please make corrections to
plans or specifications necessary to indicate compliance with applicable
codes and standards. Submit corrected plans and/or specifications to this
office for review.
For Fire Depatfment Use Only
Review 1 st 2nd 3rd
CFD Job# 95305 File#
Other Agency ID
I I
2560 Orion Way Carlsbad, California 92008 (619) 931-2121
!.
m-: - 4 -1
CONCRETE !XRENGTIl AT TWF." EIGHT DAYS: 2- PSI
WSONRY: GRADE "N" CONCRETE BLOCK F M = PSI
MORTAR: TYPES 1600 PSI
GROUT: 2000 PSI
REINFORCLNGSIEEL A-61s . ' GRADE 40: XS AND LESS (U.O.N.)
STRUCTURAL STkEL A-36
GRADE GO: #6 AND LARGER
LUMBER: DOUGLAS FIR-LARCH
JOISTS #2
. .. .. . .. ..
f .. ...
-a
nono~qm ., TAYLOR: ENGINEE:RXNG
..STRUCTURAL CALCULATXONS
.. ' s 1 R u c T (I R A L C ON SU LT.1 ti G
.~ .
BEAMS AND POSTS #1
STUDS CONSTRUCTION OR BElTER
SLQFaG ELBT
ROOFING
PLYWOOD
101sTs
INSUL. & CLG.
MISC
TOTAL = __ -
SLOPING
FLAT
LCEL EM1.
FLOORING WIFRIOR 10 PSF
PLYWOOD EXTERIOR 16 PSF
IOISIS
INSUL & CLG.
MISC
TOTAL = - __ -
INTERIOR 40 PSF
BALCONY GO PSF (U.O.N.)
EXITWALKWAY 100 PSF
'Ih& dculations arc liiitcd only Io Ihc ilcms indudcd hucin, sclcdcd
by Ihc clicnt and do not imply approval of any othcr podon 01 thc smcturc by this ofice.
. .. ..
. .. , I. .i . . .. ...
VI14 MumhvCnnvm Rd. . Site A103 . Son Dieqo. California 92123 . (619) 5604383 . FAX (619) 5608842
I
1
PLAN CORRECTION
RESUBMITTAL 96- 129.
ff:
a-
i
4-
4-
8-
1-
U-
q-
1-
1-
1-
I --
I-
!-
I-
1-
I-
I-
~ .- . . . * --
'7 j
! .;
r'
I ..
I
...
~
i !
i i-
II'
1-
1-
I-
I-
1-
1-
I-
1-
1-
1-
1-
1-
1-
1-
-
-
-
PROJECT DIRECTORY
PROJECT DATA
W
0
LL J 3%
,, ..,.I
.(..,.
SECT ION, .. . . .-... ,I ., .:
1
a.
..
..
\-
_. . . . .. ._ . .
T-361 P.86
a
.
i
.
1
I
1
1.
1
1
1
3
I \ I
I FIVE YEAR LIMITED WARRANTY FOR SUNBRELLA FIRESIST'
certificate of flame 3Res;is;tante
10 12 3) 95
RtGISTERfD
COKM No. AIPUCATIOM ISSUtO BY
GLEN RAVEN WILLSIINC- 1851 N. PARK AUE
GLEN RAVEN NC 27215
919-227-621 1 This is to certify that the materials described on the reverse side hereof have been flame-
retardant treated (or are inherently nonflamable).
FOR 2937 WEST 25th STREET AT ASTRUP COMPANY
441 13 STATE Onlo CIM CLEVELAND - Certification is hereby made that: (Check "a" or"b''1 i] (a) The articles described on the reverse side of this Certificate have been treated with a flame- retardant chemical approved and reglrtered by the State Fire Marshal and that the application
of soid chrmical was done in conformance with the laws of the State of California and the Ruler
and Regulations of the State Fire Marshal.
Method of application
material registered and approved by the State Fire Marshal lor such use.
Trade name of flame- resistant fabric or material used FR SUNBRELLA
- Name of chemical used Chem. Reg. No.
(b) Tho articles described on the reverse side hereof are made from a flameererirtont fabric or
R~~,N~. F-368 -
The flame Retardant Process Used WILL.mn Be Removed By Washing ill or wilt not) - DAYID 1- EDGERTONIO~Y.WGR.
nth BY GLEN RAVEN HILLSlfNC.
NO~B e.! Pndation Supbrintbndent
We hereby certify this to be a true co of the original"CERTlFlCA1E OF FLAME RESISTANCE" issued to us,
The ASTRUP COMPANY
- "original copy" of which has been PY i ed with the California State Fire Marshal.
60000 YO -
NtroUlot # Quantity ~~
37155 SUNBRELLA FIRESIST 8637160 FR atomer order # Description
16122 898637 .... 'up Invoico # Product Code
ACME AYN I TENT CO 2819 UNIVERSITY AVE. - SAN OIEGO CA 92104
Carlsbad 96-129
February 1,1996
GENERAL PLAN CORRECTION LIST -
JURISDICTION: Carlsbad PLAN CHECK NO.: 96-129 - I I PROJECT ADDRESS: 1818 Aston Ave. I
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 1/25/96 I - I DATE RRllEW COMPLETED
February 1,1996
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
1. Please make all corrections on the original tracings and submit two new sets of prints to:
ESGIL CORPORATION.
To facilitate rechecking, please identify, next to each item, the sheet of the plans
upon which each correction on this sheet has been made and return this sheet
with the revised plans.
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
where they are located on the plans. Have changes been made not resulting from this
list?
2.
3.
R Yes \ No
5.
manufacturer's name and ICBO # for the expansion anchors. .
7' Carlsbad 96-129
February 1,1996
7. Clearly show on the plans the required edgelend distance requirements for the
expansion anchors, as specified in the ICBO report.
8. The jurisdiction has contracted with Esgil Corporation located at 950 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 6191560-1468, to
perform the plan review foryour project. If you have any questions regarding these plan
review items, please contact Kurt Culver at Esgil Corporation. Thank you.