Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1819 ASTON AVE; 104; CBC2017-0561; Permit
Print Date: 03/23/2018 Job Address: 1819 Aston Ave, 104 Permit Type: BLDG-Commercial Parcel No: 2121201100 Valuation: $147,204.15 Occupancy Group: U Dwelling Units Bedrooms: eccity of Carlsbad Commercial Permit Permit No: CBC2017-0561 Work Class: Tenant Improvement Status: Closed - Finaled Lot U: ' Applied: 10/27/2017 Reference U: Issued: 01/24/2018 Construction Type: Permit Finaled: Bathrooms: Inspector: TFraz Orig. Plan Check U: Final Plan Check U: Inspection: 3/23/2018 8:22:48AM Project Title: Description: BIORX: 3,165 SF T.I. (B,S,F TO B,F OCCUPANCY) Applicant: Owner: SMITH CONSULTING ARCHITECTS LANIKAI MANAGEMENT BRIAN DRACHE 13280 Evening Creek Dr S. 125 2382 Faraday Ave, 310 San Diego, CA 92128-4101 CARLSBAD, CA 92008 858-793-4777 Contractor: BURGER CONSTRUCTION 11760 Sorrento Valley Rd, Ste A SAN DIEGO, CA 92121-1018 858-755-1800 BUILDING PERMIT FEE ($2000+) $796.40 BUILDING PLAN CHECK FEE (BLDG) $312.11 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $89.00 FIRE F Occupancies TI S $609.00 FIRE Haz Mat Storage Chem Class 26-100 Chems $1,062.00 MANUAL BUILDING PLAN CHECK FEE $205.59 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $55.00 PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL $86.00 5B1473 GREEN BUILDING STATE STANDARDS FEE $6.00 STRONG MOTION-COMMERCIAL $41.22 Total Fees: $3,262.32 Total Payments To Date: $3,262.32 Balance Due: $0.00 Please take NOTICE that approval of your project includes the Imposition of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exaction. You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov ITHE FOLLOWING APPROVALS REQUIRED PRIORTO PERMIT ISSUANCE: DPLANNING DENGINEERING DBUILDING - DFIRE DHEALTH DHAZMAT!APCD 0. I Building Permit Application Plan Check No .c 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value 9'7 1T1 \/ CITY OF - Ph: 760-602-2719' Fax: 760-602-8558 . . -.---- 1 Plan Ck. Deposit CARLSBAD . email: building@carlsbadca.gov Date 10 (2.711 1 www.carlsbadca.gov JOB ADDRESS l8l9AstonAvenue 8UrTE#/SPACE#,'UNIT# \04- 102- 1 APN 212 - 120 - 11 - 00 CT/PROJECT # LOT # PHASE # # BATHROOMSTENANT BUSINESS NAME CONSTR. TYPE 0CC. GROUP 65 J#OFUNITS 0 JIBEDROOMS 0 -0 MAX V-B B, F-1 DESCRIPTION Of WORK Include Square Feet of Affected Area(s) INTERIOR TENANT IMPROVEMENT FOR AN ONLINE MAIL ORDER PHARMACY. INCLUDES CONSTRUCTION CONSISTING OF PARTITION WALLS, NEW LIGHTING, NEW HVAC UNIT FOR CLEAN AND ANTE ROOMS, NEW PLUMBING FIXTURES, REMODELED TOILET ROOMS AND NEW FINISHES. 250 S.F. NEW CONSTRUCTION (2- RESTROOMS), 795 S.F. REMODEL EXISTING MFG TO CLEAN ROOK 236 S.F. EXISTING OFFICE TO BREAK ROOM. TOTAL OF 1,2(1 S.F. AFFECTED BY IMPROVEMENT. 3(95SF EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) B, F-1,,3ff B, F-i ., 0 0 IDECKS(SF) 0 IFIREPLACE YESEtI. N0 JAIROONDITIONING YES 1N0D IFIRE'SPRINKLERS YES JN0D APPLICANT NAME (Primary Contact) Brian Drache APPUCANTNAME (Secondary Contact) - Peter Bussett ADDRESS - ADDRESS - - 13280 Evening Creek Dr. South, Ste. 125 -. Same as primary Cliv - STATE ZIP CITY -. STATE ZIP San Diego CA 92128 PHONE FAX - PHONE FAX 858-793-4777 _858-793-4787 EMAIL - EMAIL briand@sca-sd.com .peterb@sca-sd.com PROPERTY OWNER NAME . LanukaiManagement Co CONTRACTOR BUS. NAME Burger Construction ADDRESS ADDRESS 2382 Faraday, Suite 310P . 11760Sorrento ValleyRoad,Suite A CITY STATE ZIP CITY STATE ZIP Carlsbad _CA . _92008 _CA -San Diego _92121 PHONE FAX PHONE 858-945-8969 _. 858-755-1800 T EMAIL ' EMAIL L.J.4. I gjs@lanikaimanagement.com -. MCl/DESIGNER NAME & ADDRESS STATE LIC. A STATE UC# 5 0 4'5 7_I /3 CLASS CITY BUS. UC.# Smith Consultina Architects _Cli 701 _?-° 9or (sec. 701.5 Business and Professions Code: Any City or County which requires a, to construct, alter, Improve, demolish or repair any structure, prior to its Issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of DMsion 3 of the Business and Professions Code) or that he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). c!9®((3oDo° G®0 Workers' Compensation Declaration:! hereby affirm under penally of perjury one of the following declarations: [-] I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit Is Issued. Di have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance canter and policy number are: Insurance Co 7ij#5)WQ Policy No. -9/,_£2a33 Expiration Date___________ seoton need not be completed if the permit is for one hundred dollars ($100) or less. Certificate of Exemption: I certify that In the performance of the work for which this permit is Issued, I shall not employ any perscn in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code Interest and attorney's fees, CONTRACTOR SIGNATURE - ENT - DATE 0o0e00006 00(3 avow - Ihereby affirm that I am exempt from Conh,acto,'s License Law tar Me following reason: - - I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). C] I, as owner of the property, am exolusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). C] lam exempt under Section _Business and Professions Code for this reason: - - 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement QYes Dtia - 2.I (have ! have not) signed an application for a building permit for the proposed work. - - - 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): - 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address! phone contractors' license number): - 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name ! address phone type of work): . - - - 5PR0PERTY OWNER SIGNATURE ' - - - : '[]AGENT - DATE - . - CPZQ'G ¶IWOO 09000 L00I1 G900-03000009MZG Q(DOO&)@ 0110 (XXLS7 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? LJYes 'L--,No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? []Yes U No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? [ ,Yes L No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. (300017000901130 (G000 n0803V I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (I) Civil Code). - Lender's Name Lender's Address - 0(313I)9 03O000000 I ceilifythatl have read the application and statethatthe above Information Is correct and thatthe informatIon on the plans is accurate. I agieetocomplywlth all Cltyordinancesand State laws relatingto building coristrucllon. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILmEs, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. 051-IA An OSHA permit is requited for excavations over 50' deep and demolition or construction of structures over 3 stories in height EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by Imitation and become null and void I the building or work authorized by such permit is not commenced within l8o days from the date ofsuch permit orif the building or work authorized by such permit is suspended orabandoned at any time after the work iscommenced for period of 180 days (Section 106.4.4 Uniform Building Code). .APPLICANT'S SIGNATURE DATE - Je2j./p'......... - STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CE RTI FICATE OF OC C UPANCY (Com me rci al P rojects Onlyl Fax (760) 602-8560, Email buiIdinaCarlsbadCa.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME -. ' ' ' - OCCUPANT NAME -.- --,-. ADDRESS ' - BUILDINGADDRESS' - - - CITY - - T MATE ZIP - CITY STATE - ZIP Carlsbad CA PHONE - FAX - -.-- - . - EMAIL ..- , - - ., .- OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) 'OCCUPANT (Listed above), - CONTRACTOR (On Pg. 1) . 'ASSOCIATED CB# MAIL TO: CONTACT (Listed above) - i OCCUPANT (Listed above) - CONTRACTOR (On Pg. 1) -' . : NO CHANGE IN USE/ NO CONSTRUCTION MAIL / FAX TO OTHER: . . - -- r CHANGE OF USE / NO CONSTRUCTION APPLICANT'S SIGNATURE- ' DATE .4 Permit Type: BLDG-Commercial - Aplication Date: 10/27/2017 Owner: LANIKAI MANAGEMENT Work Class' - Tenant Improvement -. .' - Issue Date: 01/24/2018 - Subdivision: CARLSBAD TCT#85-24 UNIT#04 Status • Closed -'Finalèd Expiration Date: 09/04/2018 Address: 1819 Aston Ave. 104 Carlsbad, CA 92008-7338 S - IVR Number: 7288 * S t .. Actual .. S Inspection Type Inspection No. - Inspection Status Primary Inspector -' Reinspection Complete Date Start Date S Checklist Item . -' COMMENTS S Passed S S S BLDG-Building Deficiency HVAC curb on roof OK to dry, in with roofing - Yes S -- ••- - - _S - 03/23/2018 03/23/2018 BLDG-Final 052644-2018 Passed - Tim Frazee . Complete S • S Inspection - . . '• . - -: • - . .5 _9_ • - 4 -' S - 1,_ .•_ •_ 4, . • - i' 1 Checklist Item- * - COMMENTS - .-' • - Passed S - S S BLDG-Building Deficiency • ••' Yes S - BLDG-Plumbing Final - - . ' * Yes S BLDG-Mechanical Final - . - Yes • - - .• BLDG-Structural Final --' '., •- - - Yes -S S j_*4 SI -, BLDG -Electrical Final - Yes -S 4 •9.ç • _ 44 4 ., ; ' -• - - - S S 5 • - • --S - - • 4 4 I • - 5 . 5 •5;'• - -'- -- - - S • - - '-• - - - - - .- 5'. 9 - .- . \_ 4 -' - 4' 5 - - - - - S - . • . S - . -I - • - - •- S ' - S _5. S • ,S -• --- .1 . ' 5- _•. 4 -. 5 4 5,_ 9' - * . . - 0 ' -.:- •. - , *4 5 S ••• 'a - - , S -- 4 4 1 -- - , 45 - • 'S 4 - . S • S S ••. 4',. March 23, 2018 - -. -4 . -. . •• 5 - ••, S - Page 2 of 2 Permit Type: BLDG-Commercial ,. Application Date:. 10/27/2017 Owner: LANIKAI MANAGEMENT Work Class: Tenant Improvement . Issue Date: 01/24/2018 Subdivision: CARLSBAD TCT#85-24 UNIT#04 Status Closed Finaled Expiration Date 09/04/2018 Address 1819 Aston Ave 104 - Carlsbad, CA 92008-7338 IVR Number: 7288 -. - Scheduled Date Actual Start Date Inspection Type Inspection No. . Inspection Status . Primary Inspector Reinspection Complete 01/26/2018 01/26/2018 BLDG-14 046980.2018 r '. Passed Tim Frazee Complete Frame/Steel/Bolting! ' Welding (Decks) Checklist Item ' COMMENTS . , Passed - BLDG-Building Deficiency, . . Yes BLDG 21 04697111-2018 Passed Tim Frazee Complete linderground!Underf * loor.Plumbing -. Checklist Item . .•• ,.COMMENTS. .,. Passed BLDG Building Deficiency Yes BLDG-22'. 046979.2018 - Passed - Tim Frazee . . ' , Complete Sewer/Water Service Checklist Item . COMMENTS . .. ' . . Passed - - BLDG-Building Deficiency . - Yes 01/31/2018 01/31/2018 ' BLDG-14 - 047404-2018 . Passed - Tim Frazee Complete Frame/Steel/Bolting! . , . Welding (Decks) . . . ' Checklist Item -.COMMENTS . ' ' . - Passed -, BLDG-Building Deficiency '- . . , . Yes , BLDG-34 Rough ' 047403-2018 ', Passed Tim Frazee . Complete Electrical Checklist Item ..' COMMENTS . . . , Passed - BLDG-Building Deficiency . , . * Yes - 02/07/2018 02/07/2018, BLDG-17 Interior 048035.2018 , -- Passed - Tim Frazee Complete • - Lath/Drywall - . - - Checklist Item COMMENTS . - - - Passed. BLDG-BuildingDeficiency - . -, - Yes 03/01/2018 03/01/2018 BLDG-85 T-Bar, , 050263-2018 ' Passed Tim Frazee , Complete Ceiling Grids, . -•, .Overhead - - Checklist Item ' - : COMMENTS ,. . - ,. - Passed - - BLDG-Building Deficiency, * . - • . . . - , .' Yes BLDG-14 . . - Yes Frame-Steel-Bolting-Welding . - . - • . (Decks) ,- .• - - BLDG-24 Rough-Topout - . . - , ' Yes BLDG-34 Rough Electrical , • , - Yes BLDG-44 -. ' , , - Yes - Rough-Ducts-Dampers 03/07/2018 03/07/2018 BLDG-14 050893.2018 - ' ' Passed Frazee . , . Complete Frame/Steel/Bolting! - Welding (Decks) -• March 23, 2018 - - - . • . .- . . - ., - Page 1 of 2 I I U ho-O. oil h.O.a. ,ii •J;lz:tlxobl h !n flu. ,I DdQ ! r tvIl(.ni I 1 Im phg4s, fl,Inlirioj,I4w,d $4I fill a; V. 'o 1Jr'). rir1¼*II t t i . i '. C -- ii on, Rommmgm JU _________ 4tI! cui IM1 . _______ ________ r,._,.....lJIOiflFJ41II!A c11L 7j7 si n ,suimo !".99 7i !9/ 11 U!IL1-IL (PIT t LI.i1f(TWAL In • . - • _________ w- -II - j •-__ N nwu 1 Ago ____ j ---- POL OM OW mwwma - - Rm— I _________ - r EsGil A SAFEbuUtCompany DATE: 1/11/2018 JURISDICTION :CCItofJCar1sbad I APPLICANT a-j URIS. PLAN CHECK #.: CBC2017-0561 SET: II PROJECT ADDRESS: 1819 Aston Ave Suite 102 PROJECT NAME: BioRx - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the checklist is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacte.__.— Telephone #: Date contacted: Email: Mail Telephone Fax WPerson REMARKS: By Jason Pasiut Enclosures EsGil GA EJ, MB PC 1/9/2018 9320Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 'I EsGil A SAFEbuiLtCompany DATE: 11/7/17 JURISDICTION: City of Carlsbad PLAN CHECK#.: CBC2017-0561 SET:! PROJECT ADDRESS: 1819 Aston Ave Suite 102 PROJECT NAME: BioRx - TI LI PPLICANT URIS. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. . The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Brian Drache Telephone #: 858-793-4777 Date cjonacted: 1 1 j_. (byit..) Email: briand@sca-sd.com Mail çeron'a Fax In Person REMARKS: By: Doug Moody Enclosures: EsGil LI GA LI EJ [1 MB El PC 10/30/17 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad CBC2017-0561 11/7/17 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK#.: CBC2017-0561 OCCUPANCY: B/Si ITYPE OF CONSTRUCTION: VB IALLOWABLE FLOOR AREA: SPRINKLERS?: YES JURISDICTION: City of Carlsbad USE: Office /Warehouse ACTUAL AREA: 3156sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 60 DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: 10/27/17 ESGIL CORPORATION: 10/30/17 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Doug Moody COMPLETED: 11/7/17 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad CBC2017-0561 11/7/17 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring two corrected sets of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: Floor Area of improvement to be 3165 sf. Please notify the City of Carlsbad the cover sheet is in error and the area of improvement is 3165 sf. 2. Please provide a hard-lid framing plan. Detail the connection of the ceiling joist to the new walls and existing demising wall (the detail 17 on AD2 does not address the ledger connection). Sec. 107.2. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.3 a) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position. And where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. Clearly indicate on the plans the fume hood exhaust ventilation system compliance with CIVIC Chapters 5 & 6. Detail the required make-up air as per CIVIC, Section 505.3. Detail the exhaust outlet clearances as per CIVIC, Sections 504.5 (Environmental) & 506.9 (Product conveying). Clearly show the type of material to be exhausted by each exhaust system. Clearly show the duct materials are suitable for the intended use. CIVIC, Section 506.1 & 610.1. City of Carlsbad CBC2017-0561 11/7/17 Clearly show the exhaust duct material and gage used for each duct size. See CIVIC Table 506.2(1). Detail duct cleanouts as per CIVIC Section 506.3. Detail duct support as per CIVIC Sections 506.5 & 610.5. Detail fire protection as per CIVIC Sections 506.6 & 610.6. 5. Please complete the plumbing plans to show all vent piping sizing, show on the water line the location of the trap primers for the floor drains and show the water lines to the new sink S-I. Advisory Note : When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: The area of specific alteration, repair or addition must comply as "new" construction. A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. The path of travel shall include the existing parking. Existing toilet and bathing facilities that serve the remodeled area must be shown to comply with all accessibility features. Please address the following comments that are the result of the alterations. Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tepant space. Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, liandrails, provide dimensioned parking stall details etc. Please correct the men's restroom plan to show the required clearance at the accessible stall door minimum of 60" in the direction of the door swing not obstructed by the urinal. At least one side partition at the accessible water closet(s) must have a toe clearance of at least 9" (unless the stall width is increased to 66"). Section 11 B- 604.8.1.4. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. City of Carlsbad CBC2017-0561 11/7/17 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they-are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: YesU No ' L3 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. LWA City of Carlsbad CBC2017-0561 11/7'17 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK#.: CBC2017-0561 PREPARED BY: Doug Moody DATE: 11/7/17 BUILDING ADDRESS: 1819 Aston Ave Suite 102 BUILDING OCCUPANCY: B/Si BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 3165 46.51 147,204 Air Conditioning Fire Sprinklers TOTAL VALUE 147,204 Jurisdiction Code Icb IBY Ordinance I Bldg. Permit Fee by Ordinance V Plan Check Fee by Ordinance Type of Review: Complete Review I $796.46 I I /$517.701 E Structural Only Repetitive Fee 'H Repeats EJ Other Hourly Hr. @ * EsGil Fee I $453.981 Comments: Sheet of 1 404h> CITY OF CAR LSBAD PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division REVIEW CHECKLIST 1635 Farada'y Avenue (760) 602-4610 P28 www.carlsbadca.gov DATE: 11/8/17 PROJECT NAME: BloRx PROJECT ID: PLAN CHECK NO: CBC20I7-0561 SET#: I ADDRESS: 1819 Aston Avenue, Suite 102 APN: 2121201100 This plan check review is complete and has been APPROVED bythe Division. By: Chris Moore A Final Inspection by the Planning Division is required Yes J No You may also have corrections from one Or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from all divisions This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: chris.moore@carlsbadca.gov For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING''ENGINEERING'-FIRE PREVENTION 760-6024610 760-602-2750 760-6024665 Chris Moore ChrisGlassen : 760-602-4608 Chris.Moore@carlsbadca.gov 602-27 84 - S Christopher.Glassen@carlsbadca.gov [] Gina Ruiz VaiRay Marshall Cindy Wong 760-602-4675 760-602-2741 760-602-4662 - Glna.Rulz@carlsbadca.gov Val Ray.Marshall@carlsbadca.gov Cvnthia.Wonp@carlsbadca.gov Linda Ontiveros S Dominic Fieri 760-602-2773 760-602-4664 Linda.Ontiveros@carlsbadca.gov Domlnic.Fieri@carlsbadca.gov Remarks: See corrections below. Plan Check No. CBC20I7-0561 Address 1819 Aston Avenue, Suite 104 Date 11/6/17 Review # I Planner Chris Moore Phone(760)602-4608 APN: 2121201100 Type of Project & Use: Online mail order pharmacy, minor remodel of existing industrial/office use. Net Project Density: DU/AC Zoning: C-M General Plan: PI Facilities Management Zone: 5 CFD (in/out) #_Date of participation: Remaining net dev acres:_____ (For non-residential development: Type of land use created by this permit: industrial building) REVIEW #: 1 2 3 Legend: Z Item Complete El Item Incomplete - Needs your action LI Environmental Review Required: YES El NO Z TYPE Industrial building and current/proposed land use at 1819 Aston Avenue has been approved based on Carlsbad Research Center Specific Plan EIR, and multiple related Specific Plan amendments. No additional CEQA documentation is required. DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: LI LI LI Discretionary Action Required: YES LI NO TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: N/A Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: See comments below. LI LI Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES 0 NO CA Coastal Commission Authority? YES El NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): LI LI Habitat Management Plan Data Entry Completed? YES LI NO LI N/A If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Energov Z LI LI Inclusionary Housing Fee required: YES [1 NO D N/A (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES LI NO LI P-28 Page 2 of 4 07/11 For construction of inclusiônary units, email notification provided to HNS?: YES El NO LI (Email Susan Steinkemp in HNS with project number and contact info) OEM Housing Tracking Form (form P-20) completed: YES El NO El N/A Site Plan: Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. City Council Policy 44— Neighborhood Architectural Design Guidelines El El 1. Applicability: YES [II NO Z El El 2. Project complies: YES El NOaN/A Zoning: El El 1. Setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Top of slope: Required Shown El El 2. Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown El El Lot Coverage: Required Shown OK El El Height: Required ShOwn OK El El Parking: Spaces Required I space/250 SF Shown I space/250 SF (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown El El Additional Comments See below. 1. The Building Permit Application states the job address as 1819 Aston Avenue, Suite 102, however, the Building Plans state the address as 1819 Aston Avenue, Suite 104. Please clarify the correct Suite number, and correct either the application or the building plans accordingly. P-28 Page 3 of 4 07/11 2. The Building Permit Application states the Existing Use as* "B, F-I, S-I" and the Proposed Use as "B, F-I ", indicating a change of use. However, the building plans (sheet TSI, Existing Project Data) states the following: "Existing Occupancy Groups: B, Fl", "Proposed Occupancy Groups: B, Fl." Please correct the Building Permit Application or Building Plans to resolve this inconsistency. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE P-28 Page 4of4 07/11 Enviralab Sterility Module MCIENVIRCO Enviralab® Sterility Module 01 "9h Innovators in clean air technology Unidirectional Flow Clean Bench TECHNICAL ENGINEERING SPECIFICATION Introduction A self-contained clean work station with unique unidirectional airflow pattern providing the non-aspirating action of vertical flow while retaining the positive work protection of horizontal flow. The Enviralab® Sterility Module (ESM) is a completely self contained, positive pressure, unidirectional airflow clean bench that provides an ISO Class 5* (Class 100) environment within its work area. The ESM has a modular design with a unique airflow pattern that provides the non-aspirating action of vertical flow, while retaining the positive work protection of horizontal flow. Standard Features An ISO Class 5* environment utilizing an aerosol challenged HEPA filter. Exclusive airflow design with an all stainless steel interior construction. Fluorescent lighting fixture providing 100 foot candles at the work surface. Shielded ultraviolet lamp enhances sterilization of the work surface when the cabinet is not in use. Perforated, anodized aluminum diffuser screen protects the HEPA filter and maintains a uniform airflow velocity within the work area. Stainless steel I.V. rod. Covered duplex electrical outlet. Color-keyed airflow meter. CSAApproved. > Three sizes with optional base support stands. Options Lab Service, Part No. 10190. Additional Duplex Electrical Outlet, Part No. 10652 Matching 3-Foot Support Stand, Part No. 10761. Matching 4-Foot Support Stand, Part No. 10170. Matching 6-Foot Support Stand, Part No. 10316. Applications The high performance Enviralab Sterility Module has successfully demonstrated its versatility in a wide variety of applications and industries. > Pharmaceutical Preparation. I.V. Admixtures. Hyperalimentation. Syringe Filling. Tissue Culture. Media Preparation. Critical Sample Preparation. Microscopy Analysis. O Warranty Limited 1-year warranty. * As defined by the latest ISO 14644 and lEST Recommended Practices, where particle count does not exceed 3520 particles, 0.5 pm or larger per cubic meter of air. RECEIVED JAN 04 RECV Clyy 8UILoI4RLso IV/SjO 1V Innovators in Clean Air Technology I www.envirco.com E-ESM, Octl09 Enviralab® Sterility Module ENVIRCD Unidirectional Flow Clean Bench Innovators in clean air technology TECHNICAL• ENGINEERING SPECIFICATION.. a Dimensional information 87 F . _r_ L....Y NOTE: Provides product protection only. Does not protect personnel - . Enviralab's unique, or thó environment from aerosols generated within the work area. positive pressure, unidirectional airflow pattern sweeps around obstructions, minimizing reverse turbulence while.r maximizing cleansing within the critical work area -, 4 '4 .( ..- 0 Specification I Construction . . . Electrical . . Welded steel cabinet with exterior finished in polyurethane Standard 15 Amp, 115 V, single phase, 60 Hz, rubber covered enamel. Stainless steel work area. , . ,. cord with 3-prong ground plug. Covered duplex electrical outlet - , installed on right rear wall. Separate blowerand light switches. Filters . . 220 Volt, 50-60 Hz available. . . .- Aluminum framed High Efficiency Particulate Air. (HEPA) type, with a minimum efficiency of 99.99% at 0.3 micron, aerosol 'Motor/BiowerAssembly -' challenged (zero probed).. . . . . . Direct drive, continuous duty 1/4 Hp (ESM-3), 1/3 Hp (ESM - A) or 1/2 Hp (ESM-6) with sealed-for-life bearings and inherent Prefilters . . '. .. .. . overload protection. Motor/blower assembly is designed to Disposable - 30%ASHRAE. . provide rated airflow through a 50% increase in initial static pressure. Airflow 90 feet per minute ±10 FPM average velocity measured 6 inches Speed Controller . from the diffuser screen. Uniformity ±20% of average or better. Solid state speed control with RFl suppression for adjusting airflow velocity I, ,..- . 4 Envirco USA . European Sales Asian Sales and Manufacturing 101 McNeill Road The Cavendish Centre - Building #1 - Sanford, NC 27330, USA . - Winnail Close Tel: 919.775.2201 . Winchester, Hampshire,, . . 200 Middle Suhong Road , Suzhou, Jiangsu PRC 215021.. . Toll Free: 800.884.0002 S023 OLB, UK ' ' . ', . . Tel: +86.512.62587180 Fax:800.458.2379 Tel: +44(0)1962.840465 , . . -, Fax: +86.512.62580031 www.envirco.com " Fax +44(0)1962 828619 email lnfo@envirco corn email: info@envirco.com . www.trion.co.uk . -. . . S •. . . email: ThonEMEAServiceairsysco.corn . . ©2009 Envirco'4. Envirco° is a registered trademark of Air System Components, Inc. All product specifications reflect available information at the printing of this bthchure. Envirco'4 reserves the right to revise or modify products and/or specifications without notice. E ESM Oct/09 ¶ -. " Innovators in Clean Air Technology I www.envirco.com Part No.` .. 10758 10166. 10315 Model No. .ESM-3 ESM-4 ESM-6 A 35 (914) 47 (1193) 70 (1778) B 24.25 (616) 24.25 (616) 24.25 (616) Dimension4, .0 28(711) 28(711) 28(711) D 26.13 (664) 26.13 (664) 26.13 (664) . E . 33.5(851) 44.5(1130) 67.5 (1715) F . 32.25 (819) 32.25 (819) 32.25 (819) No. of Blowers 1 j D BTU/Hr , 1000 1200 1600 Avg FPM 540(1699) 720(2039) 1080 (2719) Power Requirenients ' 60 80 -100 Amps@115 V!6OHz . . Ship Weight,ibs.. 265(120)- 370 (1 68) 510 (231) (kilograms). '4- 0 INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY (NON, WASTtWATER AUTFCRTY Date_____ Business Name 13! 10 R)< Street Address I SoM A5r-. 1e4 cia.p CA 1oe3 Email Address JAJcJ., & C$OtOPgL*, I PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement/ Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining I Milling Painting I Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuel Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting I Forming Pesticide Manufacturing / Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating) Print Shop Fertilizer Manufacturing Chemical Etching I Milling Research and Development Film/ X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap/ Detergent Manufacturing Industrial Laundry Waste Treatment/ Storage SIC Code(s) (if known): Brief description of business activities (Production/ Manufacturing Operations):_______________ or - P&4 ezp A. Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal /day): List hazardous wastes generated (type / volume): Date operation began/or will begin at this location: I /A 04 Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes If yes, when: Site Contact 9rp W4..LH Title RIO RX Signature _- Phone No. 51 3 72. '-7OO ENCINA W1STEWATER AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760) 438-3941 FAX: (760) 476-9852 L IS SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY RECORD ID # PLAN CHECK# - BP DATE I I - The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUSMATERIALSDMSION:OCCUPANCYCLASSIFICATION:(notrequiredforproIectswithIn tè-.City'of San Dieqo): Indicate by circling the item; whetheryourbusinesswilluse,process,orstoreanyofthefollowinghazardousmaterials.IfanJdf3heitemsâreircled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed poject): op - Explosive or Blasting Agents . 5. Organic Peroxides . - '9. Water Reactives 13. Coriiv C Compressed Gases 6. Oxidizers - ' 10. Cryogenics 14. Other Helthazards Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These.4 /1,"rS 4 Flammable Solids 8. Unstable Reactives 12. Radioactives Call (858) 505-6700 prior to the issuance of a building permit - FEES ARE REQUIRED Project Completion Date: ) /./j Expected Date of Occupancy: 11-2-116 YES 0 - (for new construction or remodeling projects) j, Is your business listed on the reverse side of this form? (check all that apply). ,. 0 Will your business dispose of Hazardous Substances or Medical Waste in any amount? - 0 J Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 - pounds and/or 200 cubic feet? . 0 Will your business store or handle carcinogens/reproductive toxins In any quantity? 0 - Will your business use an existing or install an underground Storage tank? 0 Will your business store or handle Regulated Substances (CaLARP)? - 0 Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? - 0 Will your business store petroleum In tanks or containers at your facility with a total facility storage capacity equal to or greater than1,320gallons?(California's AbovegroundPetroleumStorage Act).---- me answer to ai Diego, CA 92123. 0 CalARP Exempt Date Initials CalARP Required Date Initials CaIARP Complete Date Initials PARTIII:SAN DIEGOCOUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcompisdcountv.ca.gov (858) 586-2650). So stamp required if 01 Yes gvA Q3 Yes Agd 04-06 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except - those with more than one building on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate bums; residences forming part of a larger project. rExdudes garages & small outbuildings.] YES NO - 0 Will the project disturb 160 square feet or more of existing building materials? 0 JN, Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 0 (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance _ Technician? - 0 (ANSWER ONLY IF QUESTION 3 IS YES) Based an the survey results, will the project disturb any asbestos containing material? Notification - - may be required 10 working days prior to commencing asbestos removal. - 0 Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet - (www.sdaDcd.orp/info/facts/Den-nits.pdf) for typical equipment requiring an APCD permit. - 0 (ANSWER ONLY IF QUESTION 51S YES) Will the project or associated construction equipment be located within 1,000 feet of a school Briefly describe business activities: ps ib PE.. s'i& o .... Briefly describe proposed project pi.44 _- /DI .~/_17 I declare under penalty of perjury that to the best of my knowledge and true _a correct. Name of Owner or Authorized Agent S gnature of Owneror uthorized Agent Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: - BY: DATE: -II - EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD'- APCD -COUNTY-HMD - APCD COUNTY.HMD - APCD - - I-' A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (08/15) - . - . - . - , County of San Diego - DEH - Hazardous Materials Division H' City of Carlsbad Print Date: 03/26/2018 - Permit No: PREV2018-0051 Job Address: 1819 Aston Ave, 104 Permit Type: BLDG-Permit Revision Work Class: Residential Permit Revisi Status: Closed - Finaled Parcel No: 2121201100 Lot #: Applied: 02/28/2018 Valuation: $0.00 Reference #: . . . Issued: 03/14/2018 Occupancy Group: Construction Type: Permit Fina led:, -03/26/2018 - # Dwelling Units: Bathrooms: Inspector: TFraz Bedrooms: . . Orig. Plan Check #: BC20170561D Final Plan Check #: . Inspection: Project Title: Description: BIORX: ADD ROOFTOP HVAC UNIT TO WAREHOUSE "S Applicant: . Owner: Contractor: S SMITH CONSULTING ARCHITECTS • LANIKAI MANAGEMENT . BURGER CONSTRUCTION S BRIAN DRACHE 13280 Evening Creek Dr 5, 125 2382 Faraday Ave, 310 11760 Sorrento Valley Rd, Ste A San Diego, CA 92128-4101 CARLSBAD, CA 92008 - SAN DIEGO, CA 92121-1018 858-793-4777 . 858-755-1800 MANUAL BUILDING PLAN CHECK FEE . $112.50 Total Fees: $ 112.50 Total Payments To Date : $ 112.50 , Balance Due: $ 0.00 - 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov (city of Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Original Plan Check Number 2017 05) Plan Revision Number P'v&(0,Y- Od5/ ProjectAddress 1 E319 AES1VL) AV EtiT id- General Scope of Revision/Deferred Submittal: AD rnoi3 OP c2P...) k)v..-' R0orb2 LIVAC, i)i-)rr -ia c -riôi m rnoiJc' Fft) CONTACT INFORMATION: Name 2.1A) Phone 05S 73 4-77 Fax 5im Jt'LT10 ØITEC1, Address 132,0 Ev)ij, C4a D. S. 125City $sIJ tO Zip 9:Z1 2 Email Address Lr&n cLi - 6cL. Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. I. Elements revised: tZPians Calculations LI Soils fl Energy LI Other 2. 3. Describe revisions in detail List page(s) where each revision is shown Does this revision, in any way, alter the exterior of the project? LI Yes No Does this revision add ANY new floor area(s)? LI Yes No Does this revision affect any fire related issues? LI Yes Jj' No Is this a complete set? LI Yes jSNo Signature 4. Date 2Z-4-1-Le? 1635 Faraday Avenue, Carlsbad, CA 92008 EL!: 760-602-2719 E 760-602-8558 Em-aitbuilding@carlsbadca.gov www.carlsbadcagov EsGil A SAFEbuiLf Company DATE: 3/9/2018 JURISDICTION: Carlsbad IJ APPLICANT JURIS. PLAN CHECK #.: CBC2017-0561.rev PROJECT ADDRESS: 1819 Aston Ave. PROJECT NAME: BioRx HVAC Revision SET: I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. El The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: /1 (by2 ) Email: Mail Telephone Fax In Person REMARKS: PREVCBC2O18-0051 By: Jason Pasiut Enclosures: EsGil 3/5/2018 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 Carlsbad CBC2017-0561.rev 3/9/2018 (DO NOT PAY- THIS IS NOT AN INVOICE) VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK#.: CBC2017-0561.rev PREPARED BY: Jason Pasiut DATE: 3/9/2018 BUILDING ADDRESS: 1819 Aston Ave. BUILDING OCCUPANCY: B, Si BUILDING PORTION AREA (Sq. Ft.) 1 Valuation Multiplier Reg. Mod. VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code I I #N/A 1997 IJBC Building Permit Fee 1997 UBC Plan Check Fee Type of Review: Complete Review fl Structural Only Repetitive Fee El Other Q Repeats Hourly 1 Hr. @ * EsGil Fee $90.00 Based on hourly rate I $112.501 I $90.00I Comments: Sheet 1 of 1 STRUCTURAL CALCULATIONS o PROJECT: ., DESIGN ASSUMPTIONS: CONCRETE STRENGTH AT TWENTY EIGHT DAYS: PSI MASONRY: GRADE UNSI CONCRETE BLOCK F'M = PSI MORTAR: TYPE S 1,800 PSI GROUT: 2000 PSI REINFORCING STEEL: A-615 - GRADE 40: #4 AND LESS (U.O.N.) GRADE 60: #5 AND LARGER J STRUCTURAL STEEL: A-36 - LUMBER: DOUGLAS FIR-LARCH - JOISTS #2 BEAMS AND POSTS #2- STUDS STUD OR BETTER SEISMIC FORCE:' REPORT BY: RECEIVED FEB 2 82018 CITY OF CARLSBI° I fffK STRUCTURAL ENGINEERS, LLP M. 0 No. 4326 M WIND FORCE: ' REPORT NO.: SOIL PRESSURE:____________ DESIGN LOADS: . ROOF DEAD LOAD FLOOR DEAD LOAD WALL DEAD LOAD SLOPING FIAT J!L . ROOFING FLOORING ,j' INTERIOR 10 PSF PLYWOOD PLYWOOD - EXTERIOR 16 PAE JOISTS JOISTS INSUL & CIG. INSUL. & CLG. :7 - MISC. A MISC. TOTAL = TOTAL ROOF LIVE LOAD . FLOOR LIVE LOAD SLOPING = . INTERIOR * 40 PSF FLAT t BALCONY 60 PSF (U.O.N.) EXIT WALKWAY 100 PSF These calculations are limited only to theitems included herein, selected by the client and do not i m p l y a p p r o v a l o f a n y other portion of the structure by this office. These calculations are not valid if altered in any way, or not a c c o m p a n i e d b y a wet stamp and signature of the Engineer of Record. [Job No. Designed By 1 Date , I Son Diego -'14288 Danielson Street, Suite C 200, Poway, CA 92084, (858) 679-8989. Fin (858) 67918999 fcoi9x51 tH II iTI1 Iii 1T L±'±I I4I IIE =t iI4JiLIII 11111 - F F F F I F r I F F . -• -- - . . • . F F cu AtJ CAA, IL - - FMC - - F 4FFF I F .f ...i.......... .... - ............F !_.!_ .................--..-.. ...........-.......±.- ------ •F F . . i I F I I T I I F I F F 1 3 1±. / - 2-9 L6 - - -C7 : 7.1 - 4R V/6r21Q 1 4-5 i4- 1T p : 3_c:7 £'t4 vy : Ip _ KLAUSF3RLJCKNER 2495 Truxlun Road, Suite 205 AND ASSOCIATES San Diego, CA 92106 Tel: (619) 677-2004 Fax: (619) 677-2444 io=Rx- 18 19 ASTON AVE., SUITE 104 CARLSBAD, CA Hazardous Materials Inventory Report Rev. 1.0 December 19, 2017 (Sign, Print arid Date) :• * Is Rev. 1.0 Report submitted to owners. December 19, 2017 EK :• DISCLAIMER This report is the property of Klausbruckner & Associates and was prepared exclusively for use by Bio-Rx, for the hazardous materials inventory and occupancy conditions specifically described in this report Bio Rx's quantities and locations addressed herein are based on information provided for the report by Bio-Rx. Discrepancies between the information presented herein and actual conditions and conditions presented on plans are the sole responsibility of Bio-Rx. Verification of compliance with the code requirements and provisions addressed herein is outside the scope of this report Copies of this report retained by Bio Rx shall be utilized only by Bio-Rx for the hazardous materials inventory and the 2016 California Code's maximum allowable quantity, requirements addressed in this report for the above mentioned facility. This is a hazardous materials inventory report for storage and use conditions only. This is not a complete code compliance report. Hazardous materials analysis of the remainder of the building, including adjacent tenant spaces, is not part of the scope of this report. This report shall not be used as, or in lieu of, construction documents or plans for this project or any other project or for any other purpose or conditions not specifically addressed in this report Rev 1.0—Bio-Rx 1819 Aston Ave., Suite 104, Carlsbad, CA KLAUSDRUCKNER AND ASSOCIATES - - - - - - - - - - - - - - - - - - - KLAUSBRUCKNER AND ASSOCIATES - HAZARDOUS MATERIALS AND OCCUPANCY CLASSIFICATION ANALYSIS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) KLAUSBRUCKNER ) AND ASSOCIATES Table of Contents SummaryHealth Hazards .................................................................................................................................................2 SummaryPhysical Hazards .............................................................................................................................................3 Hazardous Materials Inventory ........................................................................................................................................4 SortedInventory ................................................................................................................................................................9 Applicable Codes for Health Hazards ..............................................................................................................................42 ApplicableCodes for Physical Hazards ..........................................................................................................................45 Hazard Definitions - Abbreviations .................................................................................................................................50 CodeDefinitions ................................................................................................................................................................53 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 1 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS AND OCCUPANCY CLASSIFICATION ANALYSIS CBC TABLE 307.1(2) - CFCTABLE.5003.1.1(2) SUMMARY - HEALTH HAZARD MATERIALS Bio-Rx - .1819 Aston Ave.; Suite 104, Carlsbad, CA Control Area (Entire Suite) Material Storage Storage Storage Used Closed Used Closed Used Closed Used Open Used Open Used Open (Ibs) (gins) (cfs) (Ibs) (gins) (cfs) (Ibs) (gins) (cfs) Carcinogens .3 .0000 0.0520 7.7350 2.o600 Corrosives .2 .0000 1.0000 Irritants. . . 1 3.0000. 21.5740 .7.7350 . . 4.0000 1.9705 Other Health Hazards 4.0000 23.5090 7 7350 .:9.0000 2.9705 CA-Pr9p65 0.0520 . 7.7350 Sensitizers 1.0000: .::.0:1880 2016 CALIFORNIA CODES CONTROL AREA IS CLASSIFIED AS A B Fl Si OCCUPANCY BASED ON THE USE AND STORAGE OF HEALTH HAZARD MATERIALS STORAGE AMOUNT— MAXIMUM AMOUNT IN USE AND STORAGE,UNLESSOTHERWISE NOTED. NOT ALL MATERIALS IN USE AT-THE SAME TIME, W1TH< 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED: AUTOMATICFIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &:ASSOC. -.2017-12-1.9 Page 2.of.63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS AND. OCCUPANCY CLASSIFICATION ANALYSIS CBCTABLE 307.1(1) - CFC TABLE 5003.1.1(1) SUMMARY -PHYSICAL HAZARD MATERIALS .Bio-Rx -1810 Aston Ave.; Suite 104, Carlsbad, CA - Control Area (Entire Suite) Material Storage Storage f Storage Used Closed Used Closed Used Closed Used Open Used Open Used Open (lbs) (gins) (cfs) (Ibs) (gins) (cfs) (ibs) (gins) (cfs) Aerosols Level 1 1.0000 6.0000 Aerosols Level 3 3 0000 w. 3 0000 combustjble:Ljqu,ds Ill-A 0:5000 . 0.2140 Combustible Liquids III -.B: 00420 pw 00100 Flammable Gases . 7.7350 Flammable Liquids-1-13 149130 06415 Flammable Liquids:lC 6.0410 0:8250 RMP Table 2 Federal Regulated Flammable 7 7350 Substances . : : , . :: Unstable Reactives 1 2:0000 1.0000 2016 CALIFORNIA CODES: CONTROL AREA IS CLASSIFIED AS A B, Fl, Si OCCUPANCY BASED ON THE USE AND STORAGE OF PHYSICAL HAZARD MATERIALS STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS OTHERWISE NOTED. NOTALL MATERIALS IN USE AT-THE SAME TIME, W1TH< 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED: AUTOMATIC FIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 3 of 63 HAZARDOUS MATERIALS INVENTORY Bio Rx 1819 Aston Ave.,Suite 104 Carlsbad CA Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location BiO-RX-1 L 100.0 ChioraPrep with Orange Tintf FL1B, IR; OHH 0.2970 Gins Y N Fire cabinet Isopropyl Aiôohol [67-63-0][7.0%]; Chiorohexidine Digluconate (18472-51-0][2%]; FD&C Yellow No. 6 [2783_94_0][0.35-1.25%]; [FP 67oF; LEL 2%]; [SG 0.88] 2 BIO RX 2 L 100.0 Goo Gone Pro Power Petroleum CL3A IR OHH 0.1880 Gins N N Kitchen Distiliates Hydrotreated Light SN [6474247-8][60-100%]; D Limonene [5989-27-'5][1-5%]: Orange Sweet Extract [8028-48 6][0.5-1.5%]; [FP 185 oF] 3 BiO-RX-3 L 100.0 Soft Scrub with Bleach: Sodium IR, OHH 0.2800 Gins N N kitchen Hypochiorite [7681-52-9][1-5%]; Sodium Hydroxide [1310-73-2][1- 5%];. Dodecyldimethylamine Oxide [1643-20-5][1-5%] 4 BIO RX-4 L .100.0 Bic Wite Out Water Base CL3B IR OHH 0.0420 Gins 0.0100 Gins N N Office and pharmacy Correction Fluid & Bic WtéOut Ecoiutions Water Base Correction Fluid: Titanium Dioxide [13463 67-7][30-60%];• Acrylic Acid [79- 10-7][.1-5%]; Ethylene 'Glycol [107721-1][1-5%];:Anmoniun.I Hydroxide [1336-216][.1-5%]; [F: 5 BiO-RX-5 L 100.0 3MESPE AvagardInstant-Hind IR, ORH,FL1B 7.6800 Gins 0.2600 Gins N N Fire cabinet/ Warehouse/ Antiseptic With Moisturizers: Pharmacy Ethyl Alcohol [64-17-51[50-70%] Water [7732-18-5][25735%]; Polyethylene Glycol [25322-68- 3][<3%]; Squalane [111 _'01 - 3][<2%]; Alcohols [26636-40- 8][<2%];.Docosyi Alcohol [661-19 8][<2%]; Fatty Acids [103213-20- 3][<2%]; (FP 700F]; [LFL 3.3]; [VD 1.6; SG 683] 6 BiO RX 6 L J:-100.0 Pure Bright Germicidai Uitra CR OHH UR1 2 0000 Gins 1.0000 Gins N N Fire cabinet! Ante room . .. : ... .... Bieach: Sodium Hypochiorite .. . . ., . .... .. [7681-52-9][5-7%]; [H2-FO-R1] STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WiTH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC,FIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUS. MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 4 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS INVENTORY Bio Rx 1819 Aston Ave Suite 104 Carlsbad CA Control Area (Entire Suite) Item CAS# 11 State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location 1 7 BIO-RX-7 L 100.0 HibiClens: Chlorhexidine CL3A IR, OHH 0.5000 Gins 0.0260 Gins N N Fire cabinet/Ante-room Digluconate [18472-51-0][14%]; Isopropyl Alcohol [67-63-0][14%]; [FP 148 oF] 8 BIO RX 8 L 1000 Super San, Cloth Germicidal FL1C IR OHH 1 2370 GIns 08250 Gins N N Pharmacy Wipes: lsopropyi alcohol [67-63- 0][55%];.Alkyl (60% C14, 32%... C16 5% C12 5% C18) dimethyl a. benzyl ammonium chlorides [6839101-5][0.25%]; Alkyl (68% . . . .. . .. :5a A. C12, 32%C14)dirnethyl. ethylbenzyl.amrnonium chloride [85409-23-0/68956-79-6][0.25%]; [FP 75 oF LEL 2.5%]; [SG 0.8921; [H27F3-R0] .. .. . . . .. . .. .. . . 9 BI07RX-9 L 100.0 Webcol/Curity Alcohol.Prep Pads: FL1B, IR, OHH 52100 Gins N N Warehouse. Water:[7732-18-5][25-35%]; Isopropyl Alcohol [67-63-0][65- 75%]; [FP 53.6 oF; BP 179.6 OF]; :[LFL 2%]; [VDS2.1; SG 07855] 10 BIO RX 10 L 1000 Curos Port Protectors Tips Jet FL1B PR OHH 0 1300 Gins. N N Pharmacy I.Stopper Polyethylene Cap [25087-34-7][60-90%o]; PIastiFoil LiñerStrip [5-18%]; Isopropyl .: . H .1.: . :. : Alcohol: [67-63-0][5-1 5%]; Water: . ::. . .: H . H .: . . :. [7732-18-5](2-8%]; H ; : H : Pigment/Colorants [<1%]; [FP 6496F -BP 1816F; LEL 2%]- . :[VD 2.1; SG: 0.877];[H2-F34R0] 11 BIO-RX-11 L 100.0 Site ScrubIpA Device: Isopropyl FL1B, lR, OHH, 0.0520 GIns N N Pharmacy Alcohol [67-63-0][47%]; P65, CA Diatomité [68855-54-9][<3%]; Titanium Dioxide:[13463-67- 7][<0:4%]; [FP 65;7 oF; LEL 2]; [SG0.872-0.883;VD1.63];[1-11- F3-RO] 12 BlO RX 12 L :100.0 Purell Hand Sanitizer Thanol FL1C IR OHH 4.7006 Gins N N Warehouse [64-17-5][50 70%] Propan 2 ol 5 .[67-63-0][175%]; [FP 7. oF]; [SG 0.89]; [H2-F3-RO] .... . . .... ,. . . .. . . : :. STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND STORAGE, UNLESSOTHERWISE NOTED. NOTALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES AREINCLUDED; AUTOMATIC FIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUS, MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC. - 2017-12-19 Page 5 of 6 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS INVENTORY: Bio Rx 1819 Aston Ave Suite 104 Carlsbad CA Control Area (Entire Suite) Item jj CAS# 11 State j Conc% Material Hazard Class TStorage Use-Closed Use-Open Cabs >15psi Location I 13 BlO:RX13 L 100.0 3MCavilon No Sting Film and IR, OHH, FL1B :0.0520 GIns N N Warehouse Foam Applicator: F-lexamethyldisiloxane [107-46- 0][35-65%]; Foam Applicator [33- 36%]; Isooctane [540-84-i.][0- 15%]; Acrylate Terpolymer [1- 8%]; Polyphenylmethylsiloxane Copolymer (73559-47-4)[0.1-4%]; [FP 14oF BP 14oF LEL 08] [SG 0.78]; [H1F3-R0] :14: BIO-RX-14. L I H 100.0 I:: Aplicare Alcohol Swabstick: FL1B, IR, OHH 0.1300 GIns I .• Warehouse isopropyl Alcohol [67630][60- : :1.. 80%] [FP 644 oF] [SG 0.88]; [NFPA.H2-F3-RO] . . .. . : .. .. .. . . . 15 BlORX-15 L 100.0. Aplicare Povidone-lodine IR 0.0650 GIns N N Warehouse Swabsticks: Providone-Iodine [25655418][812%]; [Hi-FO-RO] 16 BIO RX 16 L ..100.0 Prevantics Swab Swabstpck and FL1C IR, OHH 0 1040 GIns N N Warehouse Maxi SwabstickH lsoproahol [67- 63 0][70%] Chlorohexidine Gluconate [18472-51-0][3.15%]; .. .... z. . . s.. :. :, . .:. [FP 78 OF]; [H1-F3R0] 17 . BIO-RX-17 L 100.0 PDI Adhesive Tape Remover: FL1 B, IR, OHH .0.0210 GIns N N Warehouse. Naphtha (Petroleum), Hydrotreated Heavy [64742-48 9][60-100%]; Solvent Naphtha (Petroleum),. Light Aliphatic [64742-89-8](10-30%]; Isopropyl Alcohol [67-63-0][37%];:Heptane [142825][O1..1%] [FP 60 oF]; [F11-F3-R0] N N Warehouse 18 BIO RX 18 L 100.0.. Skin Prep Wipes lsopropyl FL1 B IRj OHH 0 0260 GIns Alcohol [67 63 0] [75 100%] Butenedioic Acid I(Z),:Monobuty1 . H. . ... .. . . •.:. .... .:. : . ... .:. :. . : . Ester, Polymer WI [25119.6801 . [10-25%]; [FP.5.3 oF; LEL 2.5; BP . . • . . . .. . . . . .. . . . . . . . . . . . .:. 180 oF]; [SG0.85; VD 2.1] . . .....•: : . ... . .: : . .:. . . . ... ..., STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND STORAGE,:UNLESS.OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATICIFIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUS. MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC. - 2017-1249. Page 6 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS INVENTORY Bio Rx 1819 Aston Ave Suite 104 Carlsbad CA Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage J_Use-Closed Use-Open Cabs >15psi Location 19 BIORX-19 L 100.0 SUREPREP NoStingSkin IR, OHH 0.0130 GIns N N Warehouse ProtectantS Polyurethane Copolymer [9009-54-5][50%]; 2- Propenoic acid, 2-methyl-, polymer with ethyl 2-propenoate and methyl 2-methyl [25133-97- 2][50%]; [Hi-FO-R0] 20 BIO RX 20 A 100.0:.Pledge Furniture Spray Lemon ALl IR OHH 1 0000 Lbs N N Kitchen under sink Fresh Naphtha Petoleu Light Alkylate 64741-66-8][1-5%]; [HO- ___ :1.R0] S :5 •.: .:, y :. : : : :5 21 BIO-R.X-21 A 100.0 .RustoleumPtouch 2X+SSPR AL3, IR, OHH, 3.0000 Lbs 1.0000 Lbs N N Warehouse 6PK Gloss Navajo: Propane [74- CA 98-6][10-25%]; Acetone [67-64- 1](10-25%]; Titanium Dioxide [13463-67-7][10-25%]; n-Butane [106-97-8][2.5-10%]; n-Butyl Acetate [123-86-4](2.5-10%]; Npahtha, Petroleum Hydrotreated Light [64742-49-0](2.5-10%]; Dimethyl Carbonate [616738- 6][2.5-10%]; 1 -Methoxy-2-Propyl Acetate 08-65-6][2.5 10%]; Solvent Naphtha, LightAromatic [64742-95-6][2.5-1O%]; Xylene (o- m-, pisomers) [1-330-20-7][1- 2.5%]; Propylene:Glycol Monobutyl Ether [5131-66-8][1- 2.5%], EtKylbenzene-[10041- 4][0.1-1.%]; EthyleneGlycol Monobutyl Ether [111-76-2][O.1- 1%); [H2-F4-RO] 22 BlO-RX 22 A 1000 Scotchgard Cleaner For Fiabric & AL3 IR OHH 1.'0000 Lbs N N Kitchen under sink Upholstery: Water 7732-18-5][85- CA : . •:. : . .:. : .:. 90%-:1 obutane [75-.28-5][377%1;: Sodium Lauryl Sulfate [151-21 :3][1-5%] Styrene Maleic Anhydride Copolymer [62720-34-' 9][1 5%] Organic Acid Ester Salt [1 5%] 11 Difluoroethane [75 37 6][1 3%] 2 Butoxyethanol [111 76-2][<0.5%]; Morpholine [.110- 91-8][<0.2%]; Sodiu Nitrite • • • •• • .• •• •.. :• •:. : : . [7632-OO-O][<O.2%]; 5 • • , : . • . .: . .. • . •.. Lauryldimethylamine Oxide:::.: : • : : :: : . :. • ::.. [1 643 20 5][<O 17%] [H3 Fl RO] . • ......S STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE,S UNLESS. OTHERWISE NOTED. NOT-ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED: AUTOMATICSFIRE SPRINKLER SYSTEM PROTECTION. SHAZARDOUS.MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC. - 2017-12-19 Page 7 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS INVENTORY Bio Rx 1819 Aston Ave Suite 104 Carlsbad CA Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location 23 BIO-RX-23 A 100.0 ZEP Stainless Steel POL Z: AL3, IR, OHH, 1.0000 Lbs N N Kitchen- under sink • Distillates (Petroleum), SN Hydrotreated.I-leavy Nap hthenic [64742-52-5][50-70%]; Distillates • (Petroleum); Hydrotreated Light (64742-47-5][10-20%]; Solvent Naphtha (Petroleum); Light Aliph. [64742789-8][5710%]; (R)-p- mentha-1 ,8-diene [59892751(1: 5%];Carbon Dioxide [124-38- 9][1-5%]; Solvent Naphtha • (Petroleum), Heavy Aliph. [64742- 96-7][1-5%]; Propan-2-ol(67-63- :0][1-5%] citral[5392-40-5][0.1- 1%];[H2-F4-R0] :. 24 BIO-RX-24 L. 100.0.. Dehydrated Alcohol;Injection,: FL1B,lR, OHH 0.0650 GIns :. .0.0065 GIns. N.. N Pharmacy •(stored in plastic USP Ethyl Alcohol [64 17 bin on rack)/ Clean room is 5](>I=98%] [FP 53 6oF LFL p w. where it is mixed/ used 3.3%]; ND 1.59]; [H2-F3-RO] N Stored in Warehouse & Ante- 25 67-63-0 L >1=70 Isopropanol [2-Propanol] [sec- FL113, IR, OHH 1.2500 GIns 0.3750 GIns N Propyl alcohol] [IPA] [IsOpropyl room/ Used in clean room & Alcohol) [Rubbing Alcohol] pharmacy [Sigma-Aldrich :278475]: [mw 60.1 glmol]; [FP53.6oF; BP 1800F]; [LEL 2; .UEL 12.7]; [SG 0.785; VD 2.07]; [H27F3-R1] 26 75-90-3 CG 100::.Chloroethane [Ethyl Chloride] [FP CA,FGJR, 7.7350 Cf Y N Stored in fire cabinet in 58oF BP 12 3o LEL 3.85; UEL OHH P65 pharmacy S •. 15:4%] [LC50. >2,000 ppth][MW: I . RMP-T2 . ... . . . 64.52 = 595 cf/lb] [HR H2 :F4] : :. :: : : : : : •• : : : :: . : :: H :: : : : . ...... 27 BIO-RX-27 A 100.0 Office Depot Canned- ALl, OHH 1.0000 Lbs 5.0000 Lbs N N Stored in front office:/ Used in Air/Compressed Gas Duster & office & pharmacy OfficeMax Compressed Gas Duster: :1,1..Djfluoroethane (75- 37-6][60.-.100%] 1. STORAGE AMOUNT= MAXIMUM AMOUNT IN USE ANDSTORAGE.UNLESSSOTHERWISE NOTED. NOT ALL MATERIALS IN USE ATTHE SAME TIME, WITH < 10% IN.USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC-FIRE SPRINKLER SYSTEM PROTECTION. .HAZARDOUSS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC. -2017-12-19 Page 8 of 63 - - - - - - - - - - - - - - - - - - - Aerosols Level i/AEROSOLS: Bio-Rx- 1819 Aston Ave., Suite104, Carlsbad, CA - Control Area (Entire Suite) Item 11 CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location BIO-F?X-20 A 100.0 Pledge FurnitureSprayLemon ALl, IR, OHH 1.0000 Lbs N N Kitchen - under sink Fresh: Nàphtha, Petoléu;Light Alkylate [64741-66-8][1-5%]; [HO- Fl-Rd 2 BIO RX 27 A 100 0 Office Depot Canned ALl OHH 1.0000-Lbs: 50000 Lbs N N Stored in front office:/ Used in Air/Compressed Gas Duster .& office & pharmacy OfficeMax Compressed Gas Duster, 11 Difluoroethane [75 37 6][60 100%] TOTAL - Aerosols Level 1/Aerosols 1.00 Lbs 0.00 Lbs 6.00 Lbs AGGREGATE TOTAL Aerosols Level 1/Aerosols 7.00 Lbs STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND: STORAGE.UNLESSOTHERWISE NOTED. NOT ALL MATERIALS IN USE ATTHE SAME TIME, WITH < 10% IN. USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE:SPRINKLER SYSTEM PROTECTION.. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER.&ASSOC. - 2017-12-19 Page 9.of 63 Aerosols Level 3/AEROSOLS Bio-Rx - 1819 Aston Ave., Suite.104, Carlsbad, CA -Control Area (Entire Suite) :1 Item CAS# State Conc% Material j Hazard Class Storage 1 Use-Closed Use-Open Cabs >15psi Location 1 BIO-RX-21 A 100.0 Rustoleum Ptouch 2X+SSPR AL3, lR, OHH, 3.0000 Lbs :1.0000 Lbs N N Warehouse 6PK Gloss Navajo: Propane [74- CA 98-6][10-25%]; Acetone [67r64- 1][10-259/6]; Titanium Dioxide [13463-67-7][10-25%]; n-Butane [106-97-8][2.5-10%]; n-Butyl Acetáté [123-86-4][2.5-10%]; Npahtha,. Petroleum Hydrotreated Light [P4742-49-0][2.5-1 0%] Dimethyl Carbonate [616-38- 6][2.5-10%]; 1-Methoxy-2-Propyl Acetate [108-65-6][2.5-10%]; Solvent Naphtha, Light Aromatic .[64742-95-6][2.5-10%]; Xylene (o- m-, p-isomers) [1330-20-7][1- 2.5%]; Propylene Glycol Monobutyl Ether [5131-66-8][1- 2.5°k]; Ethylbenzene.[100-41- 4][0..i-1%]; Ethylene Glycol Monobut9I Ether: [111-76-2][0:1- 1%]; [H2-F4-RO] 2 810 RX 22 A .100.0 Scotchgard Cleaner For Fiabric & AL3 IR 01-u-i 1:0000 Lbs N N Kitchen under sink J. Upholstery Water [7732-1875][85- CA 90% Isobutane [75-28_'5][3w7%]; ... Sodium Lauryl Sulfate [151-21- 3][1 5%] Styrene Maleic Anhydride Copolymer [52720 34 0][17-5%]" Organic Acid Ester Salt [1-5%]; 1,1-Difluobèth6ne 537-: 6][13%];2Butoxyethanol-[1 1 1 . . . . . 76-2][<0.5%];:Morpholine [110 91-8][<0 2%] Sodium Nitrite [7632 00 0][<0 2%] pp. . .................................. Lauryldimethylamine Oxide [1643-20-5][<0. 17%]; [H3-F1 CR0]... .. . STORAGE AMOUNT= MAXIMUM AMOUNT. IN USE AND STORAGE, UNLESS *OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS- KLAUSBRUCKNER &ASSOC. - 2017-12-19 . page 10:of 63 - - - - - - - - - - - - - - - - - - - Aerosols Level 3/AEROSOLS .. . Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# Stat1_Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi II Location I 3 BIO-RX-23 A 100.0 ZEP Stainless Steel POL Z: AL3, IR, OHH, 1.0000 Lbs N N Kitchen- under sink • Distillates (Petroleum); SN Hydrotreated:Heavy Náphthenic [64742-52-5][50-70%]; Distillates (Petroleum); Hydrotreated Light [64742-47-5]110-20%]; Solvent Naphtha (Petroleum); Light Aliph. [64742898][510%]; (R)-p- mentha-18-diene [5989-27-5][1- 5%];Carbon Dioxide [124-38 9][1-5%]; Solvent Naphtha (Petroleum), Heavy Aliph. [64742- 96-7]11-5%]; Propan-2-01[67-63- • :0][1-5%].; Citral[5392-40-5][O.1- TOTAL Aerosols Level 3/Aerosols 3.00 Lbs :0.00 Lbs 3.00 Lbs AGGREGATE TOTAL - Aerosols Level 3/Aerosols 6.00 Lbs • • STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND: STORAGE,.UNLESS:OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN.USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRESPRINKLER SYSTEM PROTECTION.. HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS - KLAUSBRUCKNER&ASSOC. - 2017-12-19 Page 11 of63 - - -, - - - - - - - - - - -..- - Carcinogens/AEROSOLS Bi0.RX 1819 Aston Ave., Suite.104, Carlsbad, CA -Control Area (Entire Suite) Item çAS# State Conc% 1 . Material 1 Hazard Class Storage Use-Closed Use-Open ] Cabs >15psi Location I BlO-RX-21 A 100.0 Rustoleum Ptouch 2X+SSPR AL3, IR, OHII, 3.0000 Lbs 1.0000 Lbs N N Warehouse 6PK Gloss Navajo: Propane [74- CA 98-61[10-25%]; Acetone [67-64- 1][10-25%];.Titanium Dioxide [13463-67-7](10-25%]; n-Butane [106-97-8](2.5-10%]; n-Butyl • Acetate [123-86-4][2.5-10%]; Npahtha,. Petroleum Hydrotreated Light: [64742-49-0][?.5-10%]; • Dimethyl Carbonate [616-38- 6](2.5-10%]; 1-Méthoxy-2-Propyl Acetate [108-65-6](2.5-10%]; So!vent Naphtha, LightAromatic [64742-95-6](25-10%] Xylene (o- m-, p-isomers) [1330-20-7](1- 2.5%]; propylene Glycol Monobutyl Ether [5131-66-8](1- 2.56/6]; Ethylbenzene [100-41- 4](0.1-1%]; Ethylene Glycol Monobutyl Ether [111-76-2][0.1- • . 1%]; [H2-F4-RO] 2 BIO RX 22 A 100.0 Scotchgard Cleaner For Fiabric & AL3 IR OHH 1:0000 Lbs N N Kitchen under sink Upholstery Water [7732-1875](85- CA 90%; Isobutane [75-285][3-7%]; . : • : : :. Sodium Lauryl Sulfate [151-21- .3][1,-5%]; Styrene Maleic Anhydride Copolymer [52720 34 0][1 5%] Organic Acid Ester Salt [1-5%]: 11 Difluoroethane [75 37 • it • .• . 76 2][<0 5%] Morpholine [110 91 8][<0 2%] Sodium Nitrite .• .6][13%];-2-Butoxyethanol-[i [7632-00-0][<0.2%]! ........................... Lauryldimethylamine Oxide :. . ; : : . . : : . : .• ........ [1643-20-5][<0. 17%]; [H3-F! _:Rol. TOTAL- Carcinógens/Aerosóls 3.00 Lbs 0.00 Lbs 2.00 Lbs w. AGGREGATE TOTAL 7 Carcinogens/Aerosols 5.00 Lbs STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND STORAGE,. UNLESS .OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FlRE:SPRINKLER SYSTEM PROTECT]ON. HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS- KLAUSBRUCKNER. & ASSOC. - 2017-12-19 Page 12 of 63 Carcinogens/COMPRESSED GASES .. Bio-Rx - 1819 Aston Ave., Suite: 104, Carlsbad, CA - Control Area (Entire Suite) Item fl CAS# ILState J_Conc% Material Hazard Class Storage Cabs >15psi Location 1 75-00-3 : CG 100 Chloroethane [Ethyl Chloride] [FP-58oF; BP 1230; LEL: 3.85; UEL: 15.4%] [LC5O >2,000.ppm] [MW: 64.52 = 5.95 cf/lb] [HR: 112 F41 CA, FG, IR, OHH; P65,. RMP-T2 7.7350Cf V N Stored in fire cabinet in pharmacy TOTAL Carcinogens/Compressed Gases 7 74 AGGREGATE TOTAL - Carcinogens/Compressed Gases 7.74 STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND sToRAGE,.uNLEss:OmERWIsE NOTED. NOT ALL MATERIALS IN USE ATTHE SAME TIME, WITH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC. 2017-12-19 Page 13of63 - - - - - - - - - - - - - - - - - - Carcinogens/LIQUIDS Bio-Rx- 1819 Aston Ave., Suite.104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Cabs >15psi Location I 1 BIORX-11 L 100.0 Site Scrub IPA Device: Isopropyl Alcohol [6763-6][4-7%]; FL1 B; IR, OHH 0.0520 GIns N N Pharmacy Diatomite [68855-54-9][<3%]; Titanium Dioxide [13463-67- P65, CA 7][<0.4%]; [FP 65.7 oF;:LEL2]; [SG 0.8724883; VD. 1.63]; [H1 ::F3-R0] TOTAL Carcinogens/Liquids w.0:05 GIns AGGREGATE TOTAL :Carcinogens/Liquids 0.05 GIns STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND: STORAGE,.UNLESS:OTHERWISE NOTED. NOT ALL MATERIALS IN USE ATTI-IE SAME TIME, WITH < 10% IN.USE AT ANY TIME UNLESS QUANTITIES ARE .INCLUDED. AUTOMATIC FIRE SPRINKLER SYSTEM PROTECTION.: HAZARDOUS MATERIALS/OCCUPANCYCLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC. - 2017-12-19 Page 14 of 63 - - - - - - - - - - - - - - - - - - - Combustible Liquids Ill-A/LIQUIDS BioRx 1819 Aston Ave., Suite 104, Carlsbad, CA -Control Area (Entire Suite) [Item I CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location BIORX-2 L' 100.0 Goo Gone Pro Power: Petroleum CL3A, IR, 01111, 0.1880 Gins N N Kitchen :Distillates, HydrotreatedLight SN [64742.47-8][60-100%]; D7 .Limonene.[5989-27-5][15%] Orange, Sweet,Extract [8028.48- 6][0515%] [FP 185 oF] 2 BIO RX 7 L 100.0.. HibiClens Chlorhexidine CL3A IR 01111 0 5000 Gins , .0 .0260 Gins. N N Fire cabinet! Ante room Digluconate [1 8472 51 0][1-4%] Isopropyl Alcohol [67 63 0][1-4%] [FP148oF]' . . .. ... TOTAL - Combustible Liquids Ill-A/Liquids 0.50 0.50 Gins: 0.00 Gins O21 Gins AGGREGATE TOTAL - Combustible Liquids Ill-A/Liquids .. :. . : 0.71 GIns. . :. .. . . :. .• .. .. :. STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND: STORAGE,.UNLESSOTHERWISE NOTED. NOT ALL MATERIALS IN USE ATTHE SAME TIME, WITH < 10% IN.USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC :FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS - KLAUSBRUCKNER. & :ASSOC - 2017-12-19 Page 15 .of.63 - - - - - - - - - - - - - - - - - - - Combustible Liquids Ill-B/LiQUiDS I Bio-Rx - 1819 Aston Ave., Suite104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >1 5psi Location I BlORX-4 : L 100.0 Bic Wite-Out Water Base CL3B, IR, OHH 00420 Gins 0.0100 GIns N N Office and pharmacy Correction Fluid & Bic WitèOut Ecolutions Water Base Correction Fluid: Titanium Dioxide [13463- 67-7][30-60%]; Acrylic Acid [79- 10-7][1-5%]; Ethylene Glycol [107-21-1][1-5%]; Ammonium Hydroxide [1336-21 -6][1-5%]; [FP >230 oF]; [H1-F1-R0] w. TOTAL Combustible Liquids III B/Liquids 0.o4 GIns 0.00 GIns 0.01 GIns AGGREGATE TOTAL - Combustible Liquids lIIB/Liquids 0.05 GIns STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND ST0RAGE,uNLEss:omERwlSE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% INUSE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC :FIRE:SPRINKLER SYSTEM PROTECTION; : HAZARDOUS MATERIALS/OCCUPANCYCLASSIFICATION ANALYSIS - KLAUSBRUCKNER.& ASSOC. - 2017-12-19 Page 16 of 63 - - - - - - - - - - - - - - - - - - - Corrosives/LIQUIDS . Bio-Rx- 1819 Aston Ave., Suite.104, Carlsbad, CA - Control Area (Entire Suite) Item[ CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cab_][>15psi lLocation I 1 1 BIORX-6 L : 100.0 Pure Bright Germicidal Ultra: CR, OHH, UR1 Bleach: Sodium Hypochlorite :[7681-52i9](5-7%]; [H27FO-R1] 20000 Gins 1.0000 Gins N N Fire cabinet/Ante-room TOTAL Corrosives/Liquids 2 00 GIns 0.00 GIns 1 00 GIns AGGREGATE TOTAL - Corrosives/Liquids . 3.00 Gins STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND: STORAGE,.UNLESS.OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WiTH < 10% IN.USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC :FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS - KLAUSBRUCKNER. & :ASSOC - 2017.-i 2-19 . Page 17 .of.63 Flámrnàble Gases/COMPRESSED GASES Bio-Rx- 1819 Aston Ave., Suite104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Cabs IL>15p51 ILocation 1 75-00-3 CG 100 Chloroethane [Ethyl Chloride] [FP 58oF; BP 12:30; LEL: 3.85; UEL: 15.4%] [LC50 >2000:ppm] [MW: 64.52 = 5.95 df/lb] (FIR: .H2 F4] CAFG, IR, 01111 P65, RMP-T2 7.7350Cf Y N Stored in fire cabinet in pharmacy TOTAL Flammable Gases/Compressed Gases T7.4 AGGREGATE TOTAL - Flammable Gases/Compressed Gases 7.74 STORAGE AMOUNT- MAXIMUM AMOUNT IN USE AND: STORAGE,,UNLESS:OTHERWISE NOTED. NOT'ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE 'INCLUDED. AUTOMATIC FIRE.SPRINKLER SYSTEM PROTECTION. ' HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS:- KLAUSBRUCKNER &ASSOC. - 2017-12-19 'Page 18 of,63 - - - - - - - - - - - - - - - - - - - Flammable Liquids i-B/LIQUIDS. Bio-Rx- 1819 Aston Ave., Suite.104, Carlsbad, CA -control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location BIO-RX-1 L 100.0 ChioraPrep with Orange Tint: FL1B, IR, OHH 0.2970 Gins Y N Fire cabinet Isopropyl Alcohol [67-63-0][70%]; Chlorohexidine Digluconate [18472-51-0][2%]; FD&C Yellow No. 6 [27834.4-0][0.35-125%); [FP 67oF; LEL2%]; [SG 0.88] 2 BIO R)( 5 L 100 0 3M ESPE Avagard Instant Hand PR OHH FL1 B 'T6 Gins .0 .2600 GIns N N Fire cabinet! Warehouse/ Antiseptic With Moisturizers Pharmacy Ethyl Alcohol [64 17 5][50 70%] .Water [73?18-5][2-35%]; . Polyethylene Glycol [25322L68 3][<3%] Squalane [iii 01 3][<2%] Alcohols [26636-40 8][<2%] Docosyl Alcohol [661 19 8][<2%]; Fatty 'Acids [103213-20- . . . . : , 3][<2%]:[FP700F][LFL33] ND: .. 1.6; SGO.83] 3 BlO-RX-9 . . ... L 100.0'. Webcól/CurityAlco'hol.Prep Pads: FL1B, IR, OHH 5.2100 Gins N N Warehouse Water [7732-18-5][25-35%]; Isopropyl Alcohol [67-63-0][65- 75%]; [FP 53.6 oF; BP 179.6 oF]; :[LFL2%] [VD.2.1; SG'0.7855] 4 BIO RX 10 L 1000 Curos Port Protectors Tips Jet FL1B IR OHH 0 1300 GIns N N Pharmacy Stopper: Polyethylene Cap .' :.. ' I • [25087-34-7][60-90%]; Plastic/Foil Liner Strip [5-18.%]; Isopropyl Alcohol [67-63-0][5-15% Water -[7732-.18m5][2_-'8%];-.-. . . . . . . Pigment/Colorants [<i%];'[FP .' . . .. 64.9 oF; BP 181 oF; LEL2%]; ND 2 1 SG 0.'877]; [H2 F3 RO] 5 . BIO-RX-1 1 L 100.0 Site Scrub 'IPA Device: Isopropyl FLi BIR, OHH, .0.0520 Gins N N Pharmacy Alcohol [67-6370][4-7%]; P65, CA .. Diatomite [68855-54-9][<3%]; Titanium Dioxide [1 3463-67- 7][<0.4%]; [FP 65.7 oF; LEL 2]; [SG 0.972-0.883; VD 1.63]; [Hi- F3-RO] STORAGE AMOUNT '= MAXIMUM AMOUNT IN USE AND: STORAGE.UNLESS:OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC .FlRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS- KLAUSBRIJCKNER &ASSOC. - 2017-12-19 :Page 19 of 63 - - -. - - - - - - - - - - - - - - - - Flammable Liquids: I-B/LIQU IDS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA -Control Area (Entire Suite) .1_lt&m CAS# I State Conc% Material fl Hazard Class Storage Use-Closed Use-Open_fl Cabs >15psi Location I 6 BIO-RX-13 L; 100.0: 3M Cavilon No Sting Film and IR, OHH, FL1B 00520 Gins N N Warehouse Foam Applicator Hexamethyldisiloxane [107-46 I 0][35-65%]; Foam Applicator. [33- 36%]; Isooctane [540-.84 1][0- -15%]; Acrylaté Terpolymer'(l- : H. 8%1; Polyp henylmethylsiloxañe : :. ':. . . :. : •. :.. Copolymer [73559-47][0.1-4%];. [FP i4oF; BP 140F:LELO8] [SG . 0.78]; [H1F3R0] .• . :. :. . : . :... :. 7 BIO-RX-14. L 100.0 .Aplicare Alcohol Swabstick: FL1B, IR, OHH 0.1300 Gins N N Warehouse Isopropyl Alcohol [67-63-0][60- 80%]; [FP 644 OF]; [SG 0.88]; [NFPA:H2-F3-RO] 8 BIO RX 17 L 1000 P01 Adhesive Tape Remover FL1B IR OHFI 00210 Gins N N Warehouse Naphtha (Petroleum) Hydrotreated Heavy [64742 48 9][60-100%]; Solvent Naphtha : H : . : •. .(Petroleum),.Light Aliphatic [64742 89 8][10 30%] Isopropyl Alcohol [67 63 0][3 7%] Heptane [142-82-5][0.1 1%] [FP 60 oF] 9 BIO-RX-18 L 100.0 Skin Prep Wipes: Isopropyl FL1B, IR, OHH 0.0260 Gins N N Warehouse Alcohol [67-63-0] [75-100%]; Butenedioic Acid. (Z)-,: Monobutyl: Ester, Polymer WI [25119.68-0] [10-25%]; [FP. 53 oF; LEL 2.5; BP 180 oF]; [SG0.85; VD 2.11 10 BIO RX 24 L 1000 Dehydrated Alcohol Injection FL1B IR OHH 00650 GIns 00065 Gins N N Pharmacy (stored in plastic USP Ethyl Alcohol [64-17- bin on rack)/ Clean room is . 5][>/=98%]; [FP 53.6oF; LFL mixed/ used 3.3%]; [VD 1.59]; [H2-F3R0] 11 67-63-0 L >1=70 lsoprCpanol [2-Propanol] [sec- FL1B, IR; OHH 1.2500 Gins 0.3750 Gins . ....whéreitis N N Stored in Warehouse & Ante- Propyl alcohol] [IPA] [Isopropyl . room/ Used in clean room & Alcohol] [Rubbing Alcohol] pharmacy [Sigma-Aldrich 278475]: [mw 60.1 g/mol]; [FP536oF; BP 1800F]; [LEL 2; UEL 12.7]; [SG 0.785; VD 2.07]; [H2-F3-R1] TOTAL Flammable Liquids I B/Liquids 14 91 Gins 0 00 GIns 0.64 Gins AGGREGATE TOTAL - Flammable Liquids I-B/Liquids 15.55 Gins= STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE,.UNLESSIOTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER.& ASSOC. - 2017-12-19 Page 20 of 63 -.-i- - - - - -. -.- - -- - - _ - - - Flammable Liquids I-C/LIQUIDS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs 11 >15psi 11 Location BiO-RX-8 L 100.0 Super Sani-Cloth Germicidal FL1 C, IR, OHH 1 2370 Gins 0.8250 Gins N N Pharmacy Wipes: isopropyl alcohol [67763- 0][55%]; Alkyl:(60% C14;32% :C1.6,5% C12,.5% C18) dimethyi benzyl ammonium chiorides [68391-01-5][0:25%]; Alkyl (68% C121 32% C14)dimethyl ethylbenzyl ammonium chloride [854097?30/68956796][0.25%]; [FP 75 oF; LEL2.5%]; [SG' 0:892]; [H2-F3R0] 2 BlO RX 12 L 1000 Purell Hand Sanitizer Thanol FL1C IR OHH 4.7000 Gins N N Warehouse 164-17-5][50-.70%1; Propan 2 01 [67-63-0][1__5%]: [FP 77 6F] ;.[SG .. 0.89]; [H2-F3-RO] N N Warehouse 3 BI07RX-16 L 100.0 Prevantics Swab Swabstick and FL1C IR; OHH ,01040 Gins Maxi Swàbstick: isopropanol [67- 63-0][70%]; Chiorohexidine Giuconate [18472-51-0](3.15%1; [FP 78.oF];[H1-F3-RO] TOTAL Flammable Liquids I C/Liquids 6.04 GIns 0.60. Gins Gins .0:.82 AGGREGATE TOTAL -'Flammable Liquids I-C/Liquids 6.87 GIns STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE,.UNLESS OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC :FIRE:sPRlNKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC. - 2017-12-19 Page 21 of 63 - - - - - -. - - - - - - - - .- - - - - Irritants/AEROSOLS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class [Storage J Use-Closed Use-Open Cabs >15psi Location BlORX-20 A 100.0 Pledge Furniture Spray Lemon ALl IR, OHH . 1.0000 Lbs N N Kitchen - under sink Fresh: Nàphtha, Petoléu Light Alkylate [64741 -66-8][1 -5%];. [HO- Fi-RO] 2 BIO RX 21 A 100.0 Rustoleum Ptouch 2X+SSPR AL3,1 lR OHFI 3.0000 Lbs 1:0000 Lbs N N Warehouse 6PK Gloss Navajo: Propane [74: CA: :. 98 6][1O 25%] Acetone [67 64 1][10 25%] Titanium Dioxide [13463-67-7][10-25%]; n Butane [106-97-8][2.5-10%]: n Butyl . Acetate (123-86-4][2.5-1O%]; Npahtha Petroleum Hydrotreated Light [64742' 9-0][2.5-10/6]; Dimethyl Carbonate [616738- 6] [2 5 10%] 1 Methoxy 2 Propyl Acetate [108-65-6][2.5-10%]; : . . . . . . .' . . . Solvent Naphtha Light Aromatic [64742 95:-6][2.5-10%];.Xylene (o m p isomers) [1330 20 7][1 2 5%] Propylene Glycol Monobutyl Ether [5131-66-8][1- 2:5%]; Ethylbenzene [100-41 '4][o.1-1%);Ethylene Glycol Monobutyl Ether [111-76-2][0.1 %] [H2-F4-RO]... . . . . 3 BIO,RX-22 A 100.0 Scotchgard Cleaner For Fiabric& AL3, IR, OHH, 1.0000 Lbs N N Kitchen- under sink Upholstery: Water [7732-18-5][85- CA 900/6; Isobutane [75-28-5][3-7%]; Sodium Lèuryl Sulfate [151-21- 3][1-5%] .Styrene Maleic Anhydride ICópoIymer [52720-34- 0][1-5%]; Organic Acid Ester Salt [1-5%]; 1,1-Difluoroethane [75-37- 6][1-3%]; 2Butoxyethanol [111- 76-2][<0:5%]; Morpholine (110- 91-8][<0.2%]; Sodium Nitrite: [7632-00-0][<0.2%]; Lauryidimethylamine Oxide [1643-20-5][<0.17%]; [H3-F1-RO] STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC .FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 22 of 63 Irritants/AEROSOLS Bio-Rx - 1819 Aston Ave., Suite.104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >l5psi Location 4 BlORX-23 A. 100.0: ZEP Stainless Steel POL Z: AL3, IR, OHH, . :. :1.0000 Lbs: N N Kitchen- under:sink H. Distillates (Petroleum) SN Hydrotreated Heavy Naphthenic 164742-52 5][50 70%] Distillates (Petroleum) Hydrotreated Light (64742-47-5][10-20%]; Solvent . : : • .................... : ..... .. Naphtha (Petroleum); Light Aliph. : : : . .................... : . . ... [64742789-8][5-j 0%] (R)-0- mentha 1 8 diene [5989 27 5][1 5%] Carbon Dioxide [124-38 . ... 9][1-5%]; Solvent Naphtha : (Petroleum), Heavy [64742- 9677][15%]; Propan-2-ol:[67-63- :p][1-5%].;Citral [5392-40 5][P.1- 1 %1; [H2F4R0] TOTAL - Irritants/Aerosols . 3.00 Lbs 0.00 Lbs 4.00 Lbs AGGREGATE TOTAL Irritants/Aerosols 7 00 Lbs STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE,.UNLESS,OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS- KLAUSBRUCKNER, & ASSOC. - 2017-12-19 Page 23 of 63 - - - - - - - - - - - - - - - - - - - Irritants/COMPRESSED GASES Bio-Rx- 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) itemCAS# State 11 Conc% Material Hazard Class_JstoragjI Cabs >l5 psi J[ocation 1 75-00-3 CG 100 Chloroethane [Ethyl Chloride] [FP-58oF; BP 123o; LEL:•3.85; UEL: 15.4%][LC50 >2,000;ppm][Mw:64.52 = 5.95 cf/lb][HR: 112 F4] CA,FG, IR, OHH P65, RMP-T2 7.7350Cf• Y N Stored in fire cabinet in pharmacy • : . :. • • : TOTAL -: Irritants/Compressed Gasè :. : • : . •• : : 774 1 .....• . •• .. ••• :. ••• :. AGGREGATE TOTAL.- Irritants/Compressed Gases : 774 — — — - — — — — — — — — man mm mm Irritants/LIQUIDS: Bio-Rx- 1819 Aston Ave., Suite104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# state Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location BlORX-1 L 100.0 ChloraPrep with Orange Tint: FL1B, IR, OHH 0.2970 Gins V N Fire cabinet Isopropyl Alcóhói [67-63-0](70%]; Chiorohexidine Digluconate [i8472-51-0][2%]; FD&C Yellow No. 6 [2783-94_0][0.35-11.25%]; [FP 67oF; LEL2%]; [SG 0.88] 2 BIO RX 2 L 100.0. Goo Gone Pro Power Petroleum CL3A IRj OHH,0 1880 Gins N N Kitchen Distillates l-lydrotreated Light SN [64742-47-8][60-100%]; D Limonene [5989-27-5][1-5%]; Orange, Sweet-Extract [8028-48- ::6][0.5- : 1:.5% [FP 185 oF] I. I' : s H :' ' ' 3 BiO-RX-3. L 100.0 Soft Sàrub with Bleach: Sodium IR, OHH 0.2800 Gins N N kitchen Hypochlorite [7681-52-9](1-5%]; Sodium Hydroxide [1 310-73-2][1 - 5%]; Dodecyldimethylamine Oxide [1643-2075][1-5%] 4 BIO RX-4 L 1000 Bic Wite Out Water Base CL3B IR OHH 00420 GIns 00100 Gins N N Office and pharmacy • '' I Correction Fluid & Bic Wité-Out Ecolutions .Water Base Correction I' •. : I: : H Fluid Titanium Dioxide [13463 67-7][30-60%];Acrylic Acid [79 10-7][1-5%]; Ethylene Glycol [1 07 2111[1 5%] Ammonium Hydroxide [1336-2176][1-5%]; [FP >230 oF] [Hi Fl RO] 5 BlO-R)(5 L 100.0 3M ESPEAvagard InstantHand IR, OHH, FL1B 7.6800 Gins 0.2600 Gins N N Fire cabinet! Warehouse/ Antiseptic With Moisturizers: Pharmacy Ethyl Alcohol (64-17-51[50-70%]; Water [7732-18-5](25-35%]; Polyethylene Glycol [2532268- 3][<3%];Squaiane [111-01- 3][<2%]; Alcohols [26636-40- 8][<2%]; Docosyl Alcohol [66i19- 8][<2%]; Fatty Acids'[103213-20- 3][<2%];[FP 700F]; [LFL 3.3]; [VD 1.6; SG 0.83]. 6 BIO RX 7 L 1000 HibiClens Chiorhexidine CL3A IR OHH 05000 GIns 00260 GIns N N Fire cabinet! Ante room Digiuconate [18472 51 0](1-4%] '• ' • • , Isopropyl Alcohol [67630][1 4%]; ' :, 5 • , ' :. , ' • I: • • • ••''' '• :(FP 148QF] :' s' s' :, • :' ' STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC IFIRESPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCYCLASSIFICATION ANALYSIS — KLAUSBRUCKNER & ASSOC. — 2017-12-19 Page 25 of 63 - - - - - - - - - - - - - - - - - - Irritants/LIQUIDS Bio-Rx- 1819 Aston Ave., Suite, 104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location 1 7 BlORX-8 L 100.0 Super Sani-Cloth Germicidal FL1 C, IR, OHH 1.2370 Gins 0.8250 Gins N N Pharmacy Wipes: Isopropyl alcohol [67-63- 0][55%]; Alkyl (60% C14, 32% C16, 5% C12,.5% C18) dimethyl benzyl ammonium chlorides [68391-01-5][0.'25%]; Alkyl (68% C12 32% C14) dimethyl ethylbenzyl ammonium chloride [85409-23-0/68956-79-6][0.25%]; [FP 75 oF; LEL2.5%]; [SG 0.892]; [H2-F3R0] 8 BIO RX 9 L 1000 Webcol/Curity Alcohol Prep Pads FL1B IR OHH 52100 GIns N N Warehouse Water [7732 '18-5][25-35%]; lsópropyl.Alcohol [67-63-0]65- . .. S . . . . • 75%]; [FP 53.6 oF; BP 179.6 OF]; . . ... ..,• .• ••. [LFL 2%]; ND 2.1; SG 0.7855]... •• . . . . . : . : 9 BIO,RX-10 L 100.0, Curos Port Protectors:- Tips, Jet, FL1B, IR, OHH 0:1300 Gins N N Pharmacy Stopper: Polyethylene Cap [25087-34-7][60-90%]; Plastic/Foil Liner Strip [5-18%]; Isopropyl Alcohol [67-63-0][5-15%]; Water [7732-1875][2-8%];. Pigment/Colorants [<1%]; [FP 64.9 oF; BP 181 oF;LEL 2%]; ND 2.1;1 SG 0.877]; [H2-F3-RO]' 10 BlO RX ii L 1000 Site Scrub IPA Device-,Isopropyl FL113 IR OHH 00520 Gins. N N Pharmacy Alcohol [67-63-0][4-7%]; .. S P65, CA .. • .. . :. ... . . . . .. Diatomite (68855-54-9][<3%]: Titanium Dioxide [13463-67- . . . . . ., . .. 7][<0.4%];:[FP.65.7 oF;:LEL:2]; :' 'I '.:'. , ''' .: ' • ;,: •' ' : . '''•' : [SG 0.8727.0,883; VD 1:64 [Hi .. F37RO] • . .. . . .. . .. . . : ii 13I0-11X-12 L 100.0 Purell Hand Sanitizer: Thanol FLiC, IR, OHH 4.7000 Gins. . N N Warehouse [64-17-5][50-70%]; Propan-2-ol [67-63-0][i-5%]; [FP .77 oF]; [SG 0.89]; [H2F3-R0] STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND STORAGE,.UNLESSSOTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS- KLAUSBRUCKNER.& ASSOC. - 2017-12-19 Page 26 of 63 - Irritants/LIQUIDS Bio-Rx- 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location 12 BlO:RX13 :. L: 100.0': 3M Cavilon No Sting Film and IR, OHH, FL1B 00520 Gins ' ' •' '''' N ': N Warehouse .. Foam Applicator Hexamethyldisiloxane [107-46 ':: ':5. S ..: : 0][35-65%]; Foam Applicator. [33- 36%]; Isooctane [540-.84- 1][0 .15%]; AcylatTerpoly'mer[1- ":1 . S . :.. 8%1; Polyphenylmethylsiloxane Copolymer [7355947-4][0.1-4%]; [FP 14oF BP 14oFLEL 0.8]; [SO: I" Q.78]; [Hi-RO] " 13 BlO-RX-14. L 100.0 .Aplicare Alcohol Swabstick: FL1B, IR, OHH 0.1300 Gins . N N Warehouse lsopropyl'Alcohol [67-63-0][60- 80%]; [FP 644 OF]; [SG 088]; [NFPA H2-F3-RO] 14 BIO RX 15 L 100.b- Aplicare Povidone Iodine IR 00650 Gins: N N Warehouse Swabsticks Providone Iodine [256554:1-8][8-1?%]; [Hi-FO-RO]: . . ''::. 15 BIO-RX-16 ' L 100.0 Prevantics Swab, Swabstick and FL1C, IR, OHH 0.1040 Gins N N Warehouse Maxi Swabstick: Isopropanol (67- . 63-0][70%]; Chiorohexidine Gluconate [18472-51-0][3.15%]; [FP 78 oF]; [H1-F3-RO] 16 BIO RX 17 L 1000 PDI Adhesive Tape Remover FL1B lR OHH 00210 Gins N N Warehouse Naphtha (Petroleum) Hydrotreated Heavy [64742 48 9][60-100%]; Solvent Naphtha 4. (Petroleum) Light Aliphatic = . [64742-89-8][10-30%]; Isópropyl . : ' . . ' . . . . ' :. • .. . . Alcohol [67L6 ' 3 0][3 7%] Heptane 1 [1 42 82 5][0 1%] [FP 60 oF] 4H1F3-R0] 17 BIO-RX-18 L 100.0 Skin Prep Wipes: Isopropyl FL1 B, IR; OHH 0.0260 Gins N N Warehouse Alcohol [67-63-0].[75-100%]; Butenedioic Acid: (Z)-; Monobutyl Ester, Polymer WI [25119.68-0] [10-25%]; [FP.53 oF; LEL 2.5; BP 180 oF]; [SG 0.85; VD 2:1] STORAGE AMOUNT = MAXIMUM AMOUNT IN USE ANDSTORAGE, UNLESS.OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WiTH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 27 of 63 - - - - - - - .- - - - - - - - - - - - Irritants/LIQUIDS - Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) Item fl_CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open_fl Cabs >15psi Location 18 BIORX-19 :. L 100.0: SUREPREP No Stuig Skin: IR,OHH 0.0130 Gins .: . .: N N Warehouse :1. Protetant:.PoIyurethaAé. Copolymer [9009-54-5][5O%]; 2 • : : Propenoic acid, 2-methyl-, polymer with ethyl 2 propenoate and methyl 2-methyl [2513397- 2](50%]; [1-11-F0R0] :.; s. •• :, :. :. 19 BIORX-24 L 100.0 Dehydrated Alcohol-Injection, FL1B, IR, OHH 0.0650 Gins 0.0065 Gins. N N Pharmacy (stored in plastic USP:- Ethyl Alc6hol[64-17- bin on rack)/ Clean room is 5][>/=98%]; [FP 53.6oF; LFL -• where it is mixed/ used 3.3%]; [VD 1.59]; [1-12-F3-RO] 20 67-63-0::. L >1=70 Isopropanol [2 Propanol] [Sec FL1 B IR OHH 1.2500 GIns 0 3750 GIns N N Stored in Warehouse .& Ante Propyl alcohol] [IPA] [Isopropyl room/ Used in clean room & ....Alcohol] [Rubbing Alcohol] . . . pharmacy [Sigma Aldrich 278475] [mw 60 1 g/mol] [FP 53 6oF BP 1800F] [LEL 2 UEL 12.7]; [SG 0.785; VD 2.07]; [1-127F3-R1] . : .. -.. -. - :, . :. •• -- : TOTAL - Irritants/Liquids 21.57 Gins 0.00 Gins 1.97 Gins AGGREGATE TOTAL Irritants/Liquids 23.54 Gins STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND:STORAGE, UNLESSSOTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, VV1TH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC .FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 28 of 63 Other. Health Hazards/AEROSOLS Bio-Rx - 1819 Aston Ave., Suite. 104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location I BIORX-20 A 100.0 Pledge Furniture Spray Lemon ALl IR, OHH 1.0000 Lbs N N Kitchen - under sink Fresh: Naphtha, Petolèu; Light Alkylate [64741 -66-8][1-5%];. [HO- F.1-RO] 2 BIO RX 21 A '100.0 Rustoleum Ptouch 2X+SSPR AL3 IR OHH, 3.0000 Lbs 1.0060 Lbs N N Warehouse 6PK Gloss Navajo: Propane 174- : CA: 98 6][10 25%] Acetone [67 64 1][10725%]; Titanium Dioxide (13463-67-7][10-25%]-,'n Butane w. [106-97-8][2.5-10%]; n-Butyl . . Acetate [123-86-4][2.5-10%]; .. : . : . ..... Npahtha Petroleum Hydrotreated Light [64142-49-01[2.5-1 Q1/6] Dimethyl Carbonate [616738- 6][2.5-10%]; 1 Methoxy 2 Propyl Acetate [108 65 6][2 5 10%] Solvent Naphtha Light Aromatic [64741279 5 6][2 5 10%] Xylene (o . m p isomers) [1330-20-7][1'-' . . . Propylene Glycol . . . . 2.5%]; Monobutyl Ether [5131-66-8][1- . . 2:5%]; Ethylbenzene [10041- 41[0.1-1%6]; Ethylene Glycol ... MónobutylEther [111-76-2][0.1- . . . . . 3 BIO-RX-22 A: 100.0 . 1%]; [H2-F4-RO]..... Scotchgard Cleaner For Fiabric & AL3, IR, OHH, 1.0000 Lbs N N Kitchen- under sink Upholstery: Water [7732-18-5][85- CA 900%; Isobutane [75-28-5][3-7%]; Sodium Lauryl-Sulfate-[151-21- 3][1-5%] .Styrene Maleic Anhydride Copolymer [52720-34- 0][1-5%]; Organic Acid Ester Salt [1-5%]; 1,1-Difluoroethane [75-37- 6][1-3%]; 2-Butoxyethanol [111- 762][<0:5%]; Morpholine [110- 91:-8][<0.2%]; Sodium Nitrite [7632-00-0][<0.2%]; Lauryldimethylamine Oxide [1643-20-5][<0.17%]; [H3-F1-RO] STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND STORAGE,,UNLESS, OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER,&ASSOC. - 2017-12-19 Page 29 of 63 - - : - - - - ---- --- - - . - - - Other Health Hazards/AEROSOLS Bio-Rx - 1819 Aston Ave., Suite, 104, Carlsbad, CA -Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location 4 BlORX-23 . A: 100.0 ZEP Stainless Steel: POL Z:•• AL3, IR, OHF-I, : : : -:1.0000 Lbs.: N N Kitchen- under sink Distillates (Petroleum) SN Hydrotreated Heavy Naphthenic ..: : . :• [64742-52-5](50-70%] Distillates : . .: . . .. (Petroleum) Hydrotreated Light • : [64742-47-5](10-20%]; Solvent Naphtha (Petroleum) Light Aliph [64742-89-8]15-10%]; (R)-p-: H. : • : . : : S: mentha 1 8 diene [5989 27 5][1 5%] Carbon Dioxide [124-38-'* 9][1-5%] Solvent Naphtha . (Petroleum), Héavy.Aliph. [64742- . : . •. : • : 96-7][1-5%]; Propan-2-ol: [67-63- : . : S . - .............. . 0][1 5%] Citral [5392-40 5][0 1 1%];[H2-F4-RO] 5 BIO-RX-27 A 100.0 Office Depot Canned- ALl OHH 1.0000 Lbs 5.0000 Lbs. N N Stored in front office /Used in Air/Compressed Gas Duster & office & pharmacy OfficeMax Compressed Gas Duster: 1,1-Difluoroethane [75- 37-6](60-100%] TOTAL Other Health Hazards/Aerosols 4 00 Lbs 0.00 Lbs 9.00. Lbs -------------------:............................ . - . -- ________..____•f . - . . AGGREGATE TOTAL - Other Health Hazards/Aerosols I 13.00 Lbs STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FlRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER.& ASSOC. -2017-12-19 Page 30 of.63 Other. Health Hazards/COMPRESSED GASES Bio-Rx- 1819 Aston Ave., Suite.104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Co] Material Hazard Class][ Storage Cabs fl >15psi fl Location I 1 75-00-3 CG 100 Chloroethane [Ethyl Chloride] [FP-58oF; BP 12.30; LEL:•3.85; UEL: 15.4%] [LC50 >2,000ppm] [MW: 64.52 = 5.95 cfllb] [HR: .H2 F4] CA, FG, IR, OHH, P65, RMPT2. 7.7350 Cf V N Stored in fire cabinet in pharmacy TOTAL Other Health Hazards/Compressed Gases T74 AGGREGATE TOTAL - Other Health Hazards/Compressed Gases 7.74 STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND: STORAGEUNLESS:OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WiTH < 10% INUSE AT ANYTIME UNLESS QUANTITIES ARE .INCLUDED. AUTOMATIC :FIRE:sPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS:- KLAUSBRUCKNER& ASSOC. - 2017-12-19 Page 31 of 63 - - - - - - - - -. - - - - - - - - .- - Other. Health Hazards/LIQUIDS:: Bio-Rx- 1819 Aston Ave., Suite:104, Carlsbad, CA -Control Area (Entire Suite) j .. CAS# 11 State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location BI6-RX-1 L 100.0 ChioraPrep with Orange Tint: FL1B, IR, OHH 0.2970 Gins Y N Fire cabinet Isopropyl Alcohol [67-63-0][70%]; Chlorohexidine Digluconate [18472-51-0][2%]; FD&C Yellow No. 6 [2783-94-0][0.35-1.25%]; [FP 67oF; LEL2%]; [SG 0.88] 2 BIO RX 2 L 1000 Goo Gone Pro Power Petroleum CL3A IRj OHH 0 1880 Gins N N Kitchen Distillates Hydrotreated Light SN (64742-47-8][60-100%]; D Limonene [5989-27-5][1-5%]; . . . . . ... . . Orange, Sweet.Extract [8028-48- 6][0.5-i.5%]; [FP 185 oF] :: .: H : .. : :: .: :: : 3 BIO-RX-3 L 100.0 Soft Scrub with Bleach: Sodium IR, OHH 0.2800 GIns N N kitchen Hypochlorite [7681 -52-9][1-5%]; Sodium Hydroxide [1 310-73-2][1- 5%]; Dodecyldimethylamine Oxide [1643-20-5][1-5%] 4 BlO RX-4 L'. .100.0 Bic Wite Out Water Base CL3B IR ,'OHH. 0'.0420 Gins 0.0100 GIns N .................... N Office and pharmacy Correction Fluid & Bic WW-Out Ecolutions .Water Base Correction Fluid Titanium Dioxide [13463 67..-7][30-60%]-.Acrylic Acid [79- 10-7][1-5%]; Ethylene Glycol [107 21 1][i 5%] Ammonium Hydroxide [1336-21-6][1-5%]; [FP : : : : . H : : : H : : H : . .. •: >230 oF] [Hi Fl RO] N N Fire cabinet! Warehouse! 5 BIO-RX75 L 100.0 3M ESPEAvagard InstantHand IR, OHH, FL1B 7.6800 Gins 0.2600 Gins Antiseptic With Moisturizers: Pharmacy Ethyl Alcohol [64-17-5][50-70%]; :Water [7732-18-5][25-35%]; Polyethylene Glycol [25322768- 3][<3%];Squalane [111-01- 3][<2%]; Alcohols [26636-40- 8][<2%]; Docosyl Alcohol [661-19- 8][<2%] :Fafty Acids [1 03213-20- 3][<2%];[FP 700F]; [LFL 3.3]; [VD 1.6; SG 0.83] N N Fire cabinet! Ante room 6 BIO RX 6 L 100 0 Pure Bright Germicidal Ultra CR OHH UR1 2 0000 GIns 1-.0000 GIns : .':Bleach: Sodium Hypochlorite : . :.. . . ... [7681-529][57%]; [H2F0R1] STORAGE AMOUNT •= MAXIMUM AMOUNT IN USE AND: STORAGE,. UNLESS OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC .FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS- KLAUSBRUCKNER &ASSOC. - 2017-12-19 Page 32 of 63 - - - - - - - - - - - - - - - - - - - Other Health Hazards/LIQUIDS: Bio-Rx - 1819 Aston Ave., Suite.104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs fl_>15psi_fl Location 7 BlORX-7 L 100.0 HibiClens: Chlorhexidine CL3A, PR, OHH 0.5000 GIns 0.0260 GIns N N Fire cabinet/Ante-room Digluconate [18472-51-0](1 .4%]; Isopropyl Alcohol [67-63-0][1-4%]; [FP 148 oF] 8 BIO RX 8 L 100.0 Super Sani Cloth Germicidal FL1C PR OHH 1 2370 GIns 0 8250 GIns N N Pharmacy Wipe§:,:l sopropyi alcohol (67-63': H : :• 0][55%];.Alkyl (60% C14, 32%. 1,'.: H.: : :: C16 50%C12,5% C18) dimethyl beñzyl ámmorffdm:chloride : : : •• . :. ... . [68391 -01-5][0.25%]; Alkyl (68% . . . .. . ... : . C12, 32%:C14) dirnethyl : . • :.. ethylbenzyl ammonium chloride 185409 23 0/689,56-79-6][0.25%]; [FP 75 oF LEL 2 5%] [SG . p.892]; [F-I2-F3-RO] . . . . . .. N N . Warehouse 9 BIO-RX-9 L 100.0 Webcol/Curity Alcohol: Prep Pads: FL1B, IR, OHH 5.2100 GIns . Water:[7732185][2535%]; Isopropyl Alcohol [67-63-0](65- 75%]; [FP 53.6 oF; BP 179.6 OF]; [LFL 2%]; ND 2.1; SG 0.7855] N Pharmacy 10 BlO RX 10 L 1000 Curos Port Protectors Tips Jet FL1B PR OHH 0 1300 GIns N Stopper Polyethylene Cap '[25087-34-7][60-90%];Plastic/Foil Liner Strip [5-18%]; Isopropyl Alcohol [67-63-0](5-15%]; Water [7732 18 5][2 8%] Pigment/Colorants [<1%] [FP -B-P-1 649 oF 81 oF LEL 2%] .•. . ND 2.1; SG 0.877]; [1-12F3-R0] . . .. . . . . .., . . . . . . . 11 BIO-RX-11 L 100.0 Site Scrub IPA Device: Isopropyl FL1B, IR, OHH, 0.0520 GIns N N Pharmacy Alcohol [67-63-01[4-7%]; P65, CA Diatomite [68855-54-9]1<3%]; Titanium Dioxide [13463-67- 7][<0.4%]; [FP 653 OF; LEL 2]; [SG 0:872-0.883;VD 1 .63]; [H1- F3-RO] 12 BlO RX 12 L 100.0 Purell Hand Sanitizer Thanol FL1C PR OHH 4.7000 GIns N N Warehouse [64-17-5][50-70%]; Propan 2 01 ... . ... [67-63-0](1-5%]; [FP 77. oF];[SG .. . . . : . . . . .. . ,. . . . . . 0.89]; [H2-F3-RO] . : . :• . . .. STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND: STORAGE,,UNLESS.OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC .FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 33 of 63 Other. Health Hazards/LIQUIDS:: Bio-Rx- 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location I 13 BIO-RX-13 L 100.0 3M:Cavilon No Sting Film and IR, OHH, FL1B 0.0520 Gins N N Warehouse Foam Applicator: Hexamethyidisiloxane [1.07-46- 0][35-65%]; Foam Applicator [33- 36%]; isooctane [540-84-1][0- 15%]; Acrylatè Terpolymer [1- 8%]; Polyphenylmethylsiloxane Copolymer [7355941-4][0.1-4%]; [FP 14oF; BP 14oF;:LEL 0.8]; [SG. 0.78]; [HlF3-R0] 14 BIO RX 14 L 1000 Aplicare Alcohol Swabstick FL1B IR OHH 0 1300 Gins N N Warehouse Isopropyl Alcohol [67-63._0][i50- 80%]; [FP 644 oF] [SG 0:88]; [NFPA.H2-F3-RO] : . . . .. : H 15 BIO-RX-16 L 100.0 Prevantics Swab, Swabstick and FL1C, IR, OHH 0.1040 Gins N N Warehouse Maxi:Swabstick: lsôpropanol [67- 63-0][70%]; Chiorohexidine Gluconate [18472-51-0][3.15%]" [FP 78 oF]; [H1-F3-RO] 16 BlO RX 17 L 1000 P01 Adhesive Tape Remover FL1B IR OHH 00210 Gins N N Warehouse Naphtha (Petroleum) Hydrotreated Heavy [6474248- . •:. . :. . : . 9][60 100%] Solvent Naphtha (Petroleum) Light Aliphatic [64742-89-8][10-30%]; Isopropyl :: . . :: :: ; :: Alcohol [(37-63-0][q-7%]; Heptane [FP 60 oF]; . . .. : . . . :. . . . . . . . . . . . . . . . . . . . 17 BIO-RX-18 L 100.0 T[H1-F3-RO] • . ... Skin Prep Wipes: Isopropyl FL1B, IR, OHH 0.0260 Gins N N Warehouse Alcohol [67L630] [75-100%]; Butenedioic Aôid (Z)-, Monobutyl Ester, Polymer WI [25119.6870] [10-256/o];[FP 53 oF; LEL 2.5;:BP :: . ...: 180 OF]; [SG 0.85;:VD 2.1] 18 BIO RX 19 L 100.0.:.SUREPREP No Sting Skin IR OHH 00130 Gins N N Warehouse . . Protectant:.Polyurethane Copolymer [9009-54-5][50%]; 2 Propenoic acid 2 methyl polymer with ethyl 2-propen6ate ... . . . . . .. :.. . .. • : . . ..... ... and methyl 2-methyl (251 3397 : . .. : . • 2][50%]; [111-FO-RO] . . . . . . . . STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS.OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC .FIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 34 of 63 - - - - - - - - - - - - - - - - - - - Other Health Hazards/LIQUIDS: Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA -Control Area (Entire Suite) Item CAS# State Con c% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location 19 BlORX-24 L 100.0 Dehydrated Alcohol Injection, FL1B, IR, OHH 00650 GIns 0.0065 GIns N N Pharmacy (stored in-plastic USP: Ethyl:Alcohol [64.17- bin on rack)! Clean room is 5][>I=98%]; (FP 53.6oF; LFL where it.is mixed! used .3 .3%]; [VD: 1.59]; (1-12F3-R0] 20 67-63-0 L >1=70 Isopropanol (2 Propanol] [Sec FL1 B IR OHH 1 2500 GIns 0 3750 GIns N N Stored in Warehouse & Ante Propyl alcohol] [IPA] [Isopropyl room! Used in clean room & Alcohol] [Rubbing Alcohol] pharmacy [Sigma Aldrich 278475] [mw 60J: g/mol] [FP 53.66F; BP 1800F] [LEL2; UEL 12.7] [SG0.785; VD 207] [H2 F3 Ri] TOTAL - OtherHealth Hazards/Liquids 23.51 GIns 0.00 GIns 2:97 GIns AGGREGATE TOTAL Other Health Hazards/Liquids 2648 GIns STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS .OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRESPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS - KLAUSBRUCKNER. & ASSOC. - 2017-12-19 Page 35 of 63 - - - - - - - - - - - - - - - - - - - CA-Pràp65/COMPRESSED GASES BioRx 1819 Aston Ave., Suite.104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# I State Conc% I Material Hazard Class Storage Cabs >15psi Location I 1 75-00-3 CG I 100 Chloroethane [Ethyl Chloride] [FP58oF; BP 123o; LEL:3.85; UEL: 15.4%][LC50 >2,000ppm] [MW: 64.52 = 5.95 cf/Ib][l-$R: H2 F4] CA,FG, IR, OHH P65, RMP-T2. 7.7350Cf V N Stored in fire cabinet in pharmacy TOTAL CA Prop65/Compressed Gases T74 AGGREGATETOTAL - CA-Prop65/Compressed Gases 7.74 STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN.USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATICFIRE:SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCYCLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 36.of.63 - - - - - - - - - - - - - - - - - - - CA-Prop65/LIQUIDS. :. Bio-Rx - 1819 Aston Ave., Suite.104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Cabs >15psi Location - 1 1 BIORX-il L. 100.0 Site Scrub IPA Device: Isopropyl Alcohol (67-63-0][4-7%] FLi B; IR, OHI-1, 0.0520 GIns N N Pharmacy Diatomite [68855-549][3%]; Titanium Dioxide [13463-67- P65, CA. H 7][<0.4%];:[FP 65.7 oF;:LEL.2]; [SG 0.8724883; VD 1.63]; [H1- F3-R0] TOTAL CA Prop65/Liquids 0:05 Gins AGGREGATE TOTAL - CA-Prop65/Liquids .: 0.05 Gins STORAGE AMOUNT- MAXIMUM AMOUNT IN USE AND: sToRAGE,uNLESs:omERwIsE NOTED. NOTALL MATERIALS IN USEATTHE SAME-TIME, WITH < 10% INUSE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE-SPRINKLER SYSTEM PROTECTION. -: -: HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS: - KLAUSBRUCKNER. & ASSOC. - 2017-12-19. page 37 of 63 - - - - - - - - - - - - - - - - - - - RMP Table 2 Federal Regulated Flammable Substances/COMPRESSED GASES Bio-Rx- 1819 Aston Ave., Suite: 104, Carlsbad, CA -Control Area (Entire Suite) Item CAS] State Conc% IL Material Hazard Class Storage fl_Cabs >15psi Location .1 75-00-3 CG 100 Chloroethane [Ethyl Chloride] [FP758oF; BP 123o; LEL::.3.85; CA;FG, IR, 7.7350 Cf UEL: 15.4%] [LC50 >2,000'ppm] [MW: 64.52 = 5.95 cf/lb] [HR: OFIH, P65, 1-12 F4] RMP-T2. V N Stored in fire cabinet in pharmacy TOTAL RMP Table 2 Federal Regulated Flammable Substances/Compressed Gases T74 AGGREGATE TOTAL - RMP Table 2 Federal Regulated Flammable Substances/Compressed Gases 7.74 : : . - .. - - - - - - -. - - Sensitizers/AEROSOLS : Bio-Rx- 1819 Aston Ave., SuiteiO4, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State Conc% Material Hazard Class Storage Use-Closed Use-Open Cabs >15psi Location BlORX-23 A: 100.0 ZEP Stainless Steel POL Z: AL3, IR, OHH, 1.0000 Lbs N N Kitchen- under sink • Distillates (Petroleum), SN HydrotreatedlHeavy Naphthenic : : [64742-525][56-70%]; Distillates (Petroleum), Hydrotreáted Light [64742-47-5](10-20%]; Solvent Naphtha (PetroleUm); Light Aliph. [64742789-8][5-1 0%]; (R)-pm:. mentha71,8-diene [5989-27-5][1- : • 5%]; Carbon Dioxide [124-38- : : 9][1-5%]; Solvent Naphtha (Petroleum), Heavy Aliph. [64742- 96 .77][1-5%1; Propan-2-ol (67-63- 0][1-5%].; Citr4l[5392-40-5](0.1- 1%]; [H2-F4-RO] TOTAL Sensitizers/Aerosols 0 00 Lbs 0 00 Lbs 1.00 Lbs AGGREGATE TOTAL -Sensitizers/Aerosols 1.00 Lbs STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE, UNLESSOTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN.USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE:SPRINKLER SYSTEM PROTECTION. • I HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS, KLAUSBRUCKNER.&ASSOC. - 2017-12-19 • page 39.of.63 - - - - - - - - - - - - - - - - - - - Sensitizers/LIQUIDS :::. . . . . . . .. ... Bio-Rx- 1819Aston Ave., Suite.104, Carlsbad, CA - Control Area (Entire Suite) Item CAS# State OConc% Material Hazard Class Storage Use-Closed Use-Open Cabs II >15psi Location BIORX-2 L 100.0 Goo Gone Pro Power: Petroleum CL3A, IR, OHH, 0.1880 GIns N N Kitchen :Distillates, Hydrotreated Light SN • ' 1647424781[60100%]; J • . • . Limonene.[5989-27-5][1-5%]; Orange, Sweet Extract [802848- 6][0.54.5%] [FP 185 oF] TOTAL Sensitizers/Liquids 0 00 GIns 000 GIns 0 19 GIns AGGREGATE TOTAL- Sensitizers/Liquids 0.19 GIns STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND: STORAGE,.UNLESS OTHERWISE NOTED. NOT ALL MATERIALS IN USE ATTHE SAME TIME, WiTH < 10% IN.USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC .FIRE:SPRINKLER SYSTEM PROTECTION.. . HAZARDOUS MATERIALSIOCCUPANCY.CLASSIFICATION ANALYSIS:, KLAUSBRUCKNER.& ASSOC. - 2017-12-19 Page 40 .of.63 - - - - - - - - - - - - - - - - - - - Unstable Reactives 1/LIQUIDS: Bio-Rx- 1819 Aston Ave., Suite: 04, Carlsbad, CA --Control Area (Entire Suite) Item CAS# 1tate1I Conc%11 Material Hazard Class V Storage Use-Closed Use-Open Cabs >15psi Location 1 1 BlORX-6 L- 100.0 Pure Bright Germicidal Ultra Bleach: Sodium Hypochlorite [7681-52-9](5-7%]; [H2F0-R1] CR, OHH UR1 2.0000 Gins 1.0000 Gins N N Fire cabinet/Ante-room TOTAL Unstable Reactives 1/Liquids 2 00 GIns 0 00 Gins 1 00 Gins AGGREGATE TOTAL Unstable Reactives 1/Liquids 3.00 Gins STORAGE AMOUNT= MAXIMUM AMOUNT IN USE ANDSTORAGE,.UNLESSOTHERWISE NOTED. NOT ALL MATERIALS IN USE ATTHE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC :FIRE:SPRINKLER SYSTEM PROTECTION... 1 . HAZARDOUS MATERIALS/OCCUPANCY.CLASSIFICATION ANALYSIS- KLAUSBRUCKNER &ASSOC. - 2017-12-19 Page 41 of.63 : - - - - - - - - - - - HAZARDOUS MATERIALS AND. OCCUPANCY CLASSIFICATION ANALYSIS CBC TABLE 307:1(2).- CFC TABLE 50031.1(2) SUMMARY.- HEALTH HAZARD MATERIALS Bio-Rx - 18.19 Aston Ave Suite 104, Carlsbad, CA Control Area.(EntireSuite) Material . Storage (Ibs) Storage (gins) Storage (cfs) Used Closed Used Closed (Ibs) (gins) Used Closed (cfs) Used Open (Ibs) Used Open (gins) Used Open (cfs) Carcinogens .: H .: 3.0000 :0.0520 .. 7.735.0 . 2Q.000 Material . Total (Ibs) Total (gins) Total (cfs) Carcinogens 5.0: 0.052 7:735 QUANTITIES NOT REGULATED BY THE 2016 CFC/CBC Material Storage Storage Storage Used Closed Used Closed Used Closed Used Open Used Open Used Open (Ibs) (gins) (cfs) (Ibs) (gins) (cfs) (Ibs) (gins) j (cfs) Corrosives •: :.: .:. ... ..: : :. . 20000 ::: : : •. . . ...! i.000b Material Total Total Total 11 (Ibs) (gins) (cfs) Corrosives 0 0 3.0 0.6 2016 CFC TABLE 5003.1.1(2) / CBC TABLE 307.1(2): MAQ PER 1ST FLOOR CONTROL AREA - H-4 OCCUPANCY REQUIRED ONLY FOR > MAQ STORAGE/AGGREGATE MAQ -. NO CABINETS: . 10,000 POUNDS - 1,000 GALLONS - 1,620 CUBIC FEET 30 GALLONS LIQUEFIED GAS STORAGE/AGGREGATE MAQ WiTH CABINETS 20000 POUNDS 2,000:6ALLONS 1,620. CUBIC FEET 60 GALLONS LIQUEFIED GAS USE-CLOSED MAQ . . 10,000 POUNDS - 1,000 GALLONS -.1,620 CUBIC FEET (3240 CUBICFEET IF IN CABINETS) - 30 GALLONS LIQUEFIED GAS USE-OPEN MAO: . . 2,000 POUNDS - 200 GALLONS 2016CFC Table 5003.11.1 / cBc:TABLE 414:2.5(1): M andS-1 OCCUPANCIES- STORAGE/DISPLAY - MAQPER CONTROL AREA: 19,500 POUNDS - 1,950 GALLONS 2016 CALIFORNIA CODES: CONTROL AREA IS CLASSIFIED AS A B, Fl, Si OCCUPANCY BASED ON THE USE AND STORAGE OF HEALTH HAZARD MATERIALS STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS 'OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED: AUTOMATIC FIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUSIMATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC: .:20171219 page 42 .of 63 - - - - - - - - - - - - - - - HAZARDOUS MATERIALS AND OCCUPANCY CLASSIFICATION ANALYSIS CBC TABLE 307:1(2) CFC TABLE 5003.1.1(2) SUMMARY - HEALTH HAZARD MATERIALS .Bio-Rx - 1819 Aston Ave; Suite 104, Carlsbad, CA Control Area (Entire Suite) Material Storage (Ibs) Storage (gins) Storage (cfs) Used Closed (Ibs) Used Closed (gins) Used Closed (cfs) Used Open (Ibs) Used Open (gins) Used Open (cfs) Irritants 30000 21 5740 7.735b. 40000 1.9705 Material Total (Ibs) Total (gins) Total (cfs) Irritants 7.0 28:5445 7.735 QUANTITIES NOT REGULATED BY THE 2016 CFCICBC Material Storage 11 (Ibs) Storage (gins) Storage (cfs) Used Closed (Ibs) Used Closed (gins) Used Closed Used Open (cfs) (Ibs) Used Open (gins) Used Open (cfs) Other Health Hazards 4 0000 235090 7 7350 I 9.0000 2.9705 Material Total (Ibs) Total (gins) Total (cfs) Other Health Hazards 13 0 46.4795- 7.735 QUANTITIES NOT REGULATED BY THE 2016 CFC/CBC 2016 CALIFORNIA CODES: CONTROL AREA ISCLASSIFIED AS A B, F1';Sl OCCUPANCY BASED ON THE USE AND STORAGE OF HEALTH HAZARD MATERIALS STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE, UNLESSOTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED: AUTOMATIC FIRE SPRINKLER SYSTEM PROTECTION. HAZA1RDOUSMATERIALS/OCCUPANCy CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &•ASSOC. - 2017-12-1.9 Page 43 of.63 HAZARDOUS MATERIALS AND OCCUPANCY CLASSIFICATION ANALYSIS CBC TABLE 3071(2).- CFC TABLE 5003:1.1(2) SUMMARY - HEALTH HAZARD MATERIALS B,o Rx 1819 Aston Ave Suite 104 Carlsbad CA Control Area (Entire Suite) Material Storage Storage Storage Used Closed Used Closed Used Closed Used Open Used Open Used Open L (Ibs) (gins) (cfs) (Ibs) (gins) (cfs) (Ibs) (gins) (cfs) CA Prop65 0.0520 7.M0 Material Total Total Total (Ibs) (gins) (cfs) CA Prop65 0.0': 0 052 7.735 ] CALIFORNIA PROPOSITION 65 SUBSTANCES CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER OR REPRODUCTIVE/DEVELOPMENTAL TOXICITY INCLUDES PRODUCTS CONTAINING CA-P65 REGULATEDSUBSTANCES REPORTING/DISCLOSURE THROUGH CUPRAAND/ORLOCAL COUNTY HEALTH AGENCIES MAY BE REQUIRED [Material Storage (Ibs) Storage (gins) Storage (cfs) Used Closed (Ibs) Used Closed (gins) Used Closed (cfs) Used Open (Ibs) Used Open (gins) j Used Open (cfs) Sensitizers j _ 1.0000 0.1880 Material Total Total Total (Ibs) (gins) (cfs) Sensitizers 1.0 :11 0.188 0.0 QUANTITIES NOT REGULATED BY THE 2016 CFC/CBC 2016 CALIFORNIA CODES: CONTROL AREA IS CLASSIFIED AS A B, Fl, Si OCCUPANCY BASED ON THE USE AND STORAGE OF HEALTH HAZARD MATERIALS STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND STORAGE, UNLESS OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE SPRINKLER SYSTEM PROTECTION. :HAZARDOUSMATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC -2017-12-19 Page 44 of 63 - - - - - - - - - - - - - - - - -. mm HAZARDOUS MATERIALS AND: OCCUPANCY CLASSIFICATION ANALYSIS CBC TABLE 3071(1) - CFC TABLE 5003.1.1(1) SUMMARY - PHYSICAL HAZARD MATERIALS Bió-Rx - :1819 Aston Ave, Suite 104, Carlsbad, CA Control Area (Entire Suite) Material Storage (Ibs) Storage (gins) Storage fs) Used Closed (Ibs) Used Closed (gins) Used Closed (cfs) Used Open 1[15ed Open (Ibs) fl (gins) Used Open (cfs) Aerosols Leveli 0000 6.0000 Material Total (Ibs) Total (gins) Total (cfs) Aerosols Level 1 7.0 0.0 0.0 2016 CFC 5104.1: UNLIMITED - QUANTITIES NOT REGULATED AS HAZARDOUS MATERIALS Material Storage Storage IL Storage Used Closed Used Closed Used Closed Used Open Used Open Used Open fl (Ibs) 11 (gins) (cfs) 11 (Ibs) 11 (gins) IL (cfs)11(Ibs) (gins) (cfs) Aerosols Level 30000 30000 Material Total Total Total (Ibs) (gins) (cfs) Aerosols Level 3 6.0 0.0 0.0 2016 CFC 51042 H OCCUPANCY OR SPECIAL REQUIREMENTS APPLICABLE TO ONLY >500 POUNDS IN GROUP A B E F I AND R OCCUPANCIES MAO PER .1ST FLOORCONTROL AREA OF LEVEL 2 AND 3.AEROSOLS COMBINED: 11,000 POUNDS OR 2,000 POUNDS IF STORED IN CABINETS. 2016 CFC TABLE 5104.3.11: NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL COMBINED IN GENERAL PURPOSE WAREHOUSES PALLETIZED OR SOLID-PILE STORAGE: 12;000 LBS RACK:STORAGE: 24,000 LBS MAQ of LEVEL 2 and 3 AEROSOL COMBINED IN NON-SEGREGATED RETAIL STORAGE AREA: 2,500 POUNDS 2016 CALIFORNIA CODES: CONTROL AREA IS CLASSIFIED AS A B, Fl, Si OCCUPANCY BASED ON THE USE AND STORAGE OF PHYSICAL HAZARD MATERIALS STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND STORAGE, UNLESSOTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC FIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 45 of 63 - - - - - /- - - - - - - - - - - - - - HAZARDOUS MATERIALS AND OCCUPANCY CLASSIFICATION ANALYSIS CBC TABLE 3071(1),. CFC TABLE 5003.1.1(1) SUMMARY - PHYSICAL HAZARD MATERIALS Bio-Rx - 1819 Aston Ave; Suite 104, Carlsbad, CA Control Area (Entire Suite) Material Storage (Ibs) Storage (gins) Storage (cfs) Used Closed (Ibs) Used Closed (gins) Used Closed Used Open (cfs) (Ibs) Used Open (gins) I Used Open (cfs) Combustible Liquids. lll-A :. 0.5000 0.Z140 1. Material Total (Ibs) Total (gins) Total (cfs) Combustible Liquids III-A .00 0714 00 2,616 CFC TABLE 5003 1 1(1)1 CBC TABLE 307 1(1) MAQ PER 1ST FLOOR CONTROL AREA H-2 OCCUPANCY FOR ONLY> MAQ WHEN USED OR STORED IN OPEN CONTAINERS/SYSTEMS OR CLOSED CONTAINERS/SYSTEMS >15 PSI H-3 OCCUPANCY FOR ONLY >MAQ WHEN USED OR STORED IN CLOSED CONTAINERS/SYSTEMS AT-</=15 PSI STORAGE/AGGREGATE MAQ - NO CABINETS:'660 GALLONS STORAGE/AGGREGATE MAQ - WITH CABINETS: 1,320 GALLONS USE-CLOSED MAQ: 660 GALLONS USE-OPEN MAQ: 160 GALLONS LIQUIDS WITH NO FIRE POINTS - 2016 CFC 5701.2 Exception 7: UNLIMITED MEDICINES FOOD COSMETICS ETC 2016 CFC 5001 1 Exception .1 & 5701.2 Exception 2 </=50/, WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </=5 LITERS/I 3 GAL UNLIMITED GROUP M OCCUPANCY .MAXIMUM QUANTITY PER.CONTROL AREA- 2016 CFC TABLE 5704.3.4.1 -COMBINATION OF I-B, I-C, II & Ill-A LIQUIDS: CEILING </.18' HIGH, SHELF STORAGE <1=6', OTHER STORAGE <ft4.5':7,500 GALLONS SPEC IALSPRINKLER SYSTEM PROTECTION: 15,000 GALLONS Material ______________________ Storage (Ibs) Storage (gins) Storage (cfs) Used Closed (Ibs) Used Closed (gins) Used Closed (cfs) Used Open (Ibs) Used Open Used Open (gIns) (cfs) Combustible Liquids 111 -13:. 00420 00100 Total (cfs) 00 Material Total (Ibs) Total (gIns) w. Combustible Liquids Ill -B 00 0.052 2016 CFC TABLE 5003 11(1)! CBC TABLE 30.7.11(j): MAQ PER 1ST FLOOR CONTROL AREA STORAGE/AGGREGATE MAQ - NO CABINETS: NOT LIMITED STORAGE/AGGREGATE MAQ WITH CABINETS NOT LIMITED USE-CLOSED MAQ: NOT LIMITED USE-OPEN MAQ: NOT LIMITED LIQUIDS WITHNOFIRE POINTS.- 2016 CFC.5701.2 Exception 7: UNLIMITED MEDICINES, FOOD, COSMETICS, ETC. -.2b16 CFC 5001.1 Exception 1 & 5701 .2Exception2: </=50% WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS <1=5 LITERS./1.3 GAL: UNLIMITED 2016 CALIFORNIA CODES: CONTROL AREA IS CLASSIFIED AS A B, Fl, Si OCCUPANCY BASED ON THE USE AND STORAGE OF PHYSICAL HAZARD MATERIALS STORAGE AMOUNT •= MAXIMUM AMOUNT IN USE AND: STORAGE,. UNLESS-OTHERWISE NOTED. NOT-ALL MATERIALS IN USE ATTHE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INcLuDED: AUTOMATIC-FIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUS: MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. -2017-12-19 Page 46 of 63 - - HAZARDOUS MATERIALS AND: OCCUPANCY CLASSIFICATION ANALYSIS CBC TABLE 307:1(1):- CFC TABLE 5003.1.1(1) SUMMARY - PHYSICAL HAZARD MATERIALS Bio-Rx - 1819 Aston Ave Suite 104, Carlsbad, CA - Control Area (Entire Suite) Material Storage (Ibs) Storage (gins) Flammable Gases Material II Total (Ibs) Total (gins) Flammable Gases : I 0.0 : :00 Storage Used Closed Used Closed Used Closed Used Open Used Open Used Open (c 11 (Ibs) (gins) (cfs) (ibs) 11 (gins) 11 (cfs) 1 7.7350 Total (cfs) :7735 2016 CFC TABLE 50031.1(1)/ CBC TABLE 3071(1): MAQ PER 1ST FLOOR CONTROL AREA - H-2 OCCUPANCY REQUIRED ONLY FOR >: MAO STORAGE/AGGREGATE MAO - NO CABINETS: 30 GALLONS - 2;000 CUBIC FEET STORAGE/AGGREGATE MAO - WITH: CABINETS: 60 GALLONS -4,000 CUBIC FEET USE-CLOSED MAO -:NOT CABINETS: 30 GALLONS:- 2,000 CUBIC FEET USE CLOSED MAQ WITH CABINETS 60 GALLONS 4,000 CUBIC FEET USE-OPEN :MAO: NOT APPLICABLE Material Storage (Ibs) Storage (gins) Storage (cfs) Used Closed (Ibs) Used Closed (gins) ji Used Closed (cfs) Used Openli (Ibs) Used Open (gins) Used Open (cfs) Flammable Liquids I B 149130 06415 Material Total (Ibs) Total (gins) Total (cfs) Flammable Liquids I B 00 15.5545 00 2016 CFC TABLE NO3.11.11(11) / CBC TABLE 307 1(1) MAQ PER 1ST FLOOR CONTROL AREA OF FLIA FLIB AND FLIC COMBINED H-2 OCCUPANCY FOR ONLY'> MAQ WHEN USED OR:STORED IN:OPEN CONTAINERS/SYSTEMS:OR CLOSED. CONTAINERSISYSTEMS:>15 PSI H-3 OCCUPANCY FOR ONLY> MAQ WHEN USED OR STORED IN CLOSED CONTAINERS/SYSTEMS AT <1=15 PSI STORAGE/AGGREGATE MAO - NO CABINETS: 240 GALLONS STORAGE/AGGREGATE MAQ : WITH CABINETS: 480 GALLONS USE-CLOSED MAO:: 240 GALLONS USE-OPEN MAO 60 GALLONS LIQUIDS WITH NO FIRE POINTS (IN ACCORDANCE WITH ASTM:D 92) -2016 CFC 5701.2 NON-APPLICABILITY 7: UNLIMITED STORAGE OF DISTILLED SPIRITS AND WINES IN WOODEN BARRELS AND CASKS -2016 CFC 5001.1 EXCEPTION 10 & 5701.2 NON-APPLICABILITY 10: UNLIMITED GROUP M OCCUPANCY -.MAXIMUM QUANTITY PER:CONTROL AREA -2016 CFC TABLE 5704.3.4.1 - COMBINATION OF I-B, I-C, II & Ill-A LIQUIDS: CEILING </18' HIGH, SHELF STORAGE:<ft6' OTHER STORAGE </45:7,500 GALLONS SPECIAL SPRINKLER SYSTEM PROTECTION: 15;000 GALLONS 2016 CALIFORNIA CODES: CONTROL AREA 18 CLASSIFIED AS A B, Fl:, Si OCCUPANCY BASED ON THE USE AND STORAGE OF PHYSICAL HAZARD MATERIALS STORAGE AMOUNT = MAXIMUM AMOUNT IN USE AND' STORAGE,. UNLESS OTHERWISE NOTED. :NOT-ALL MATERIALS IN USE :AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED AUTOMATIC-FIRE SPRINKLER SYSTEM PROTECTION. HAZARDOUSMATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &:ASSOC. - 2017-12-1:9 page 47 :0f63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS AND OCCUPANCY CLASSIFICATION ANALYSIS CBC TABLE 3071(1).- CFC TABLE 5003.1.1(1) SUMMARY - PHYSICAL HAZARD MATERIALS .Bio-Rx - 18 19 Aston Ave., Suite 104,. Carlsbad, CA Control Area (Entire Suite) Material Storage (Ibs) Storage (gins) Storage (cfs) Used Closed Used Closed Used Closed (Ibs) (gins) (cfs) Used Open (Ibs) Used Open (gins) Used Open (cfs) F!amrnableLiquids.l-C ;. 6.0410 0.8250 Material Total (Ibs) Total (gins) Total (cfs) Flammable Liquids I C 0.0: 6.866 00 2016 CFC TABLE 5003 11(1)! CBC TABLE 307.1(1): MAQ PER 1ST FLOOR CONTROL AREA OF FLIB AND FLIC COMBINED H-2 OCCUPANCY REQUIRED FOR ONLY> MAQ WHEN USED OR STORED IN NORMALLY OPEN CONTAINERS AND SYSTEMS OR CLOSED CONTAINERS OR SYSTEMS PRESSURIZED >15 PSI H-3 OCCUPANCY REQUIRED FOR ONLY> MAQ WHEN USED OR STORED IN NORMALLY CLOSED CONTAINERS AND SYSTEMS PRESSURIZED AT <1=15 PSI STORAGE/AGGREGATE MAQ - NO CABINETS . 240 GALLONS STORAGE/AGGREGATE MAQ - WITH CABINETS: 480 GALLONS USE-CLOSED MAQ: 240 GALLONS USE-OPEN MAQ: 60. GALLONS LIQUIDS WITH NO FIRE-POINTS -2016 CFC 5701.2 Exception 7: UNLIMITED MEDICINES FOOD COSMETICS ETC 2016 CFC 5001 1 Exception .1 & 5701.2 Exception 2 </5O/ WATER MISCIBLE FLAMMABLE/COMBUSTIBLE LIQUIDS & CONTAINERS </5 LITERS/5 GAL UNLIMITED GROUP M OCCUPANCY -:MAXIMUM QUANTITY PER CONTROL AREA- 2016 CFC TABLE 5704.3.41 . COMBINATION OF I-B, I-C, II & Ill-A LIQUIDS: CEILING </18' HIGH SHELF STORAGE </=6, OTHER STORAGE </=4.5:7,500 GALLONS SPECIAL SPRINKLER SYSTEM PROTECTION: 15,000 GALLONS Material Storage Storage Storage Used Closed Used Closed Used Closed Used Open Used Open I[Used open (Ibs) (gins) (cfs) (Ibs) (gins) (cfs) (Ibs) (gins) _J (cfs) RMP Table 2 Federal Regulated Flammable .. . 77350 I :5ubstahs . . . . :. Material Total Total Total (Ibs) (gins) (cfs) RELE PREVENTION / TABLE 2 REPORTING/DISCLOSURE THROUGH CURPA AND/OR LOCAUCOUNTY HEALTH AGENCIES REQUIRED FOR >/= THRESHOLD QUANTITY [>1= TQ] EMERGENCY AND RISK MANAGEMENT PLANNING/PROCEDURES MAY BE REQUIRED:THROUGH CUPRAAND/OR LOCAUCOUNTY HEALTH AGENCIES 2016 CALIFORNIA CODES: CONTROL AREA ISCLASSiFIED AS A B, Fl Si OCCUPANCY BASED ON THE USE AND STORAGE OF PHYSICAL HAZARD MATERIALS STORAGE AMOUNT= MAXIMUM AMOUNT IN USE AND:STORAGE UNLESS:OTHERWISE NOTED. NOT ALL MATERIALS IN USE AT THE SAME TIME, WITH < 10% IN USE AT ANY TIME UNLESS QUANTITIES ARE INCLUDED. AUTOMATIC-FIRE SPRINKLER SYSTEM PROTECTION. ,HAZARDOUS MATERIALS/OCCURANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC. :20171219 Page 48 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS AND. OCCUPANCY CLASSIFICATION ANALYSIS CBC TABLE 307'.1(1).- CFC TABLE 5003.1.1(1) SUMMARY.- PHYSICAL HAZARD MATERIALS .Bio-Rx -1819 Aston Ave Suite 104, Carlsbad, CA - Control Area (Entire Suite) Material Storage (Ibs) Storage (gins) Storage (cfs) Used Closed (Ibs) Used Closed (gins) Used Closed (cfs) Used Open (Ibs) Used Open (gins) Used OpenS (cfs) Unstable Reactives :1 .... : . ... . : 1.0000 Total (cfs) 0.0 Material Total (Ibs) . 2.0000 ......: Total (gins) Unstable Reactives 1 0.0::: 3 0 2.016 CFC TABLE 5003.1.1(1)! CBC TABLE 307.1(1): MAQ PER 1ST FLOOR CONTROL AREA STORAGE/AGGREGATE MAQ NO CABINETS: NOT LIMITED STORAGE/AGGREGATE MAQ WITH CABINETS NOT LIMITED USE-CLOSED MAQ: •• : NOT LIMITED USE-OPENMAQ: •.• . . NOT LIMITED 201.6 CFC TABLE 5003.11.1/ CBC TABLE 414.2.5(1)- M and S OCCUPANCIES - STORAGE/DISPLAY - MAQ PER CONTROL AREA: NOT LIMITED 2016 CALIFORNIA CODES: CONTROL AREA IS CLASSIFIED AS A B, Fl 51 OCCUPANCY BASED ON THE USE AND STORAGE OF PHYSICAL HAZARD MATERIALS STORAGE AMOUNT •=MAXIMUM AMOUNT IN USE AND: STORAGE,. UNLESSOTHERWISE NOTED. NOTALL MATERIALS IN USE AT THE SAME TIME, WITH <10% IN USE AT ANYTIME UNLESS QUANTITIES ARE INCLUDED: AUTOMATIC-FIRE SPRINKLER SYSTEM PROTECTION. • . .HAZARDOUSMATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOc -2017-12-1.9 page 49 .of.63 - - - - - - - - - - - - - - - - - - - Hazardous Materials Classification Definitions Class Name ALl Aerosols Level AL2 Aerosols Level 2 AL3 Aerosols Level 3 CA Carcinogens CA-CP Carcinogens-Consumer Products :CD : Combustible Dusts:. : .• ; CF Combustible Fibers CG-NH Compressed Gases -lnért/Non-Hazárdous . .... :.. CL2 Combustible Liquids II CL2-NFP. Combustible Liquids 11-No Fire Point .... : CL3A Combustible Liquids Ill-A CL3A NFP Combustible Liquids Ill A No Fire Point CL3B Combustible Liquids lllB CL3B NFP Combustible Liquids Ill B No Fire Point CR Corrosives (.KY ....Cryogenic Liquids- Flammable,....•. • • ••. •• • CRY-NH Cryogenic Liquids - Inert/Non-Hazardous CRY OX Cryogenic Liquids Oxidizing P EX Explosives S EX1.1 •.. : Explosives Division .1.1 • .......... . ..... .• EX1;2 Explosives. Division 1.2 Explosives Division 1:3...: • • : EX1.4 Explosives Division 1.4 .EX1.4G . • Explosives DivisiOn 1 .4G . • •.. • • • • .1 1 EX1.5 Exolosives Division 1.5 HAZARDOUS, MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. -2017-12-19 Page 50of,63 - - - a - - - - - - - - - - - - - - - Hazardous Materials Classification Definitions - - Class Name - Hazard EX1 6 Explosives Division 1.6 P FG Flammable Gases P FL1A Flammable Liquids I A I' FL1A-NFP Flammable Liquids l-A-NoFire Point P FL1 B Flammable Liquids I B P FL1 B-NFP Flammable Liquids: I-B-No Fire Point P FL1C Flammable Liquids I C FL1C-NFP Flammable Liquids 17C-'N6: Fire Point P FRF Federal Regulated Flammable Substances P FRS Federal Regulated Substances P Flammable SdlidsH: P FIT Highly Toxics . H IR Irritants H IR-CP lrritants-Consumer.Products H NH NH Nonhazardous Materials OHFI Other Health Hazards Other Health Hazards:Consumer Products H H OHH CP OP Organic Peroxides - Unclassified Detonable . P P OP1 Organic Peroxides I 0P2 Organic Peroxides II Organic Peroxides Ill P OP3 P I' P OP4 Organic Peroxides IV OP5 . : Organic Peroxides V Oxidizer Gases Oxidizers 1 OX OX1 HAZARDOUSMATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 51 of 63 - - - - - - - - - - - - - - - - - Hazardous Materials Classification Definitions j s 11'Name Hazard 0X2 Oxidizers 2 P 0X3 Oxidizers 3 P 0X4 Oxidizers 4 P P65 CA Prop65 H PSM PSM-OSHA H PY Pyrophoncs I' RAID Radioactive H RADA Radioactive Alpha H RADB Radioactive - Beta H RADG Radioactive Gamma H RMP-T1 RMP.Table 1 Federal Regulated Substances P RMP T2 RMP Table 2 Federal Regulated Flammable Substances RMP-T3 RMP Table 3 - CA Regulated Substances SlED Special Industrial Explosive Devices :SN Sensitizers H SN CP Sensitizers Consumer Products H SRS State Regulated Substances P. TX Toxics H 'URl Unstable Reactives'l UR2 Unstable Reactives 2 P UR3 Unstable Reactives 3 P UR4 Unstable Reactives 4 P WR1 Water Reactives 1 P WR2 Water Reactives 2 P WR3 Water Reactives3 P 'HAZARDOUS' MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 'Page 52.of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx -1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) HAZARDOUS MATERIALS DEFINITIONS ACID Corrosive material whose water solutions contain hydrogen ions. Will liberate hydrogen gas on contact with certain metals. Forms a salt when it reacts with a base. Tastes sour. Turns blue litmus paper red. Very chemically active. Burn, irritate or destructively attack organic tissue such as the skin, lungs, stomach. Generally incompatible with bases [alkalis]. pH=</=lto<7 AEROSOL A product that is dispensed from an aerosol container by a propellant. Level 1 Aerosol: Chemical heat of combustion </=8,600 Btu/Ib. Level 2 Aerosol: Chemical heat of combustion >8,600 Btu/Ib and <13,000 Btu/Ib. Level 3 Aerosol: Chemical heat of combustion >13,000 Btu/lb AEROSOL CONTAINER A metal can, up to a maximum size of 33.8 fluid ounces (1,000 mL), designed to dispense an aerosol product; or A glass or plastic bottle, up to a maximum size of 4 fluid ounces (118 mL), designed to dispense an aerosol product. BASE [ALKALI] Corrosive materials whose water solutions contain hydroxyl ions. Chemically opposite of an organic acid. Forms a salt when it reacts with an acid. Neutralizes acids. Very chemically active. Burn, irritate or destructively attack organic tissues such as skin, lungs, stomach. pH=>7t0>/=14 CARCINOGEN Substance that causes the development of cancerous growths in living tissue. Chemical is considered to be a carcinogen if: It has been evaluated by the International Agency of Research on Cancer (IRAC) and found to be a carcinogen; or It is listed as a carcinogen or potential carcinogen in the Annual Report on Carcinogens published by the National Toxicology Program; or Regulated by OSHA as a carcinogen. CLOSED CONTAINER A container sealed by means of a lid or other device such that liquid, vapor or dusts will not escape from it under ordinary conditions of use or handling. KLAUSBRUCKNER & ASSOCIATES - 2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 53 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx -1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) CLOSED SYSTEM The use of a solid or liquid hazardous materials involving a closed vessel or system that remains closed during normal operations where vapors emitted by the product are not liberated outside of the vessel or system. The product is not exposed to the atmosphere during normal operations. Examples: All compressed gases. Product conveyed through a piping system into a closed vessel, system or piece of equipment. COMBUSTIBLE DUST Finely divided solid materials which is </=420 microns in diameter and which, when dispersed in air in the proper proportions, could be ignited by a flame, spark or other source ignition. Combustible dust will pass through a U.S. No. 40 standard sieve. Generally: Particulate from wood sanding and grinding is 'Combustible Dust.' Particulate from wood routing is not 'Combustible Dust.' Particulate from wood saving may or may not be 'Combustible Dust.' COMBUSTIBLE LIQUID A liquid having a closed up flash point >/=1000F. Class II Combustible Liquid: Flash point >/=1000F and <1400F. Class lIlA Combustible Liquid:: Flash point >/=1400F and <2000F. Class IlIB Combustible Liquid:: Flash point >/=2000F. DOT Class 3 Materials. COMPRESSED GAS A material, or mixture of materials which: Is a gas 68oF or less at 14.7 psia of pressure; and Has a boiling point of 68oF or less at 14.7 psia which is either liquefied, nonliquefied or in solution, except those gases which have no other health- or physical-hazard properties are not considered to be compressed until the pressure in the packaging exceeds 41 psia at 68oF. The states of a compressed gas are categorized as follows: Nonliquefied Compressed Gases: Gases, other than those in solution, which are in a packaging under the charged pressure and are entirely gaseous at a temperature of 68oF. Liquefied Compressed Gases: Gases that, in a packaging under the charged pressure, are partially liquid at temperature of 68oF Compressed Gases in Solution: Nonliquefied gases that are dissolved in a solvent. Compressed Gas Mixtures: Mixture of two or more compressed gases contained in a packaging, the hazard properties of which are represented by the properties of the mixture as a whole. CONTROL AREA Spaces within a building where quantities of hazardous materials not exceeding the maximum allowable quantity per control area are stored dispensed, used or handled. See also the definition of 'Outdoor control area.' KLAUSBRUCKNER & ASSOCIATES -2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 54 of 63 HAZARDOUS MATERIALS DEFINITIONS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) CORROSIVE A chemical that causes visible destruction of, or irreversible alterations in, living tissue by chemical action at the point of contact. A chemical shall be considered corrosive if, when tested on the intact skin of albino rabbits by the method described in DOTn49 CFR 173.137, such chemical destroys or changes irreversible the structure of the tissue at the point of contact following an exposure period of 4 hours. This term does not refer to action on inanimate surfaces. Burns or destructively attacks organic tissues such as the skin, lungs, stomach - i.e.: acids, bases, caustics. General 'rule of thumb': pH <1=2-3 and >/=12 Dot Class 8 Materials. CRYOGENIC FLUID A fluid having a boiling point lower than -1300F at 14.7 psia. FLAMMABLE GAS A material which is a gas at 68oF or less at 14.7 psia which: Is ignitable at 14.7 psia when in a mixture of <1=13% by volume with air; or Has a flammable range at 14.7 psia with air of at least 12%, regardless of lower limit. The limits specified shall be determined at 14.7 psi of pressure and a temperature of 68oF. DOT Class 2 Materials. FLAMMABLE LIQUEFIED GAS A liquefied compressed gas which, under a charged pressure, is partially liquid at a temperature of 68oF and which is flammable. FLAMMABLE LIQUID A liquid having a closed cup flash point <100oF. Class IA Flammable Liquid: Flash point <73oF and boiling point <1000F. Class lB Flammable Liquid: Flash point <73oF and boiling point >/1000F. Class II Flammable Liquid: Flash point >/=73oF and <1000F. DOT Class 3 Materials. FLAMMABLE MATERIAL A material capable of being readily ignited from common sources of heat or at a temperature of 600oF or less. FLAMMABLE SOLID A solid, other than a blasting agent or explosive, that is capable of causing fire through friction, absorption or moisture, spontaneous chemical change, or retained heat from manufacturing or processing, or A solid which has an ignition temperature below 212oF which burns so vigorously and persistently when ignited as to create a serious hazard. Test Data - CPSC 16 CFR; Part 1500.44: a chemical that ignites and burns with a self-sustained flame at a rate greater than 0.1 inch per second along its major axis. DOT Class 4.1 Materials. FLAMMABLE VAPORS OR FUMES The concentration of flammable constituents in air that exceeds 25 percent of their lower flammable limit (LFL). KLAUSBRUCKNER & ASSOCIATES -2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 55 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) HAZARD RATING [DEGREES OF HAZARD] Health [Blue]: Hazard rating of health hazards ranked according to the probably severity of the effects of exposure to personnel as follows: 4: Materials that on very short exposure could cause death or serious residual injury, including those too dangerous to be approached without specialized protection equipment - i.e.: * Inhalation/Absorption - Skin: Materials that, under normal conditions or under fire conditions, are extremely hazardous through inhalation of through contact with or absorption by the skin. * Ingestion - Oral: Materials whose LD50 for acute oral toxicity is <1= 5 milligrams per kilogram [mg/kg]. * Skin: Materials whose LD50 for acute dermal toxicity is <1=40 milligrams per kilogram [mg/kg]. * Dusts & Mists - Inhalation: Dusts & mists whose LC50 for acute inhalation toxicity is </=0.5 milligrams per liter [mglL]. * Liquids - Inhalation: Liquid whose saturated vapor concentration at 200C is >1= 10 times its LC50 for acute inhalation toxicity, if its LC50 is </=1,000 parts per million [ppm]. * Gases - Inhalation: Gas whose LC50 for acute inhalation toxicity is </=1,000 parts per million [ppm]. 3: Materials that on short exposure could cause serious temporary or residual injury, including those requiring protection from all bodily contact - i.e.: * Combustion Products: Materials that give off highly toxic combustion products. * Ingestion - Oral: Materials whose LD50 for acute oral toxicity is >5 milligrams and </=50 milligrams per kilogram (mg/kg]. * Skin: Materials whose LDSO for acute dermal toxicity is >40 milligrams and </=200 milligrams per kilogram [mg/kg]. * Dusts & Mists - Inhalation: Dusts & mists whose LC50 for acute inhalation toxicity is >0.5 and </=2 milligrams per liter [mg/L]. * Liquids - Inhalation: Liquid whose saturated vapor concentration at 200C is >/= its LC50 for acute inhalation toxicity, if its LCSO is </=3,000 parts per million (ppm] and does not meet the criteria for degree of hazard 4. * Gases - Inhalation: Gas whose LC50 for acute inhalation toxicity is >1,000 and <3,000 parts per million [ppm]. * Corrosive: Materials that are either severely corrosive to skin on single, short exposure or cause irreversible eye damage. 2: Materials that on intense or short exposure could cause temporary incapacitation or possible residual injury, including those requiring the use of respiratory protective equipment that has an independent air supply - i.e.: * Combustion Products: Materials that emit toxic or highly toxic irritating combustion products. * Lack of Warning Properties: Materials that, under normal conditions or fire conditions, give off toxic vapors that lack warning properties. * Ingestion - Oral: Materials whose LD50 for acute oral toxicity is >50 milligrams and </=500 milligrams per kilogram [mg/kg]. HAZARD RATING [DEGREES OF HAZARD] - continued Health [Blue] - continued: * Skin: Materials whose LD50 for acute dermal toxicity is >200 milligrams and </=1,000 milligrams per kilogram [mg/kg]. * Dusts & Mists -Inhalation: Dusts & mists whose LCSO for acute inhalation toxicity is >2 and </=10 milligrams per liter [mg/L]. * Liquids - Inhalation: Liquid whose saturated vapor concentration at 200C is >/= 1/5 its LCSO for acute inhalation toxicity, if its LC50 is </=5000 parts per million [ppm] and does not meet the criteria for degree of hazard 3 or 4. * Gases - Inhalation: Gas whose LC50 for acute inhalation toxicity is >3,000 and </=5,000 parts per million [ppm]. * Irritant: Materials that cause severe but reversible respiratory, skin or eye irritation. 1: Materials that on exposure could cause irritation but only minor residual injury, including those requiring the use of an approved air-purifying respirator - i.e.: * Combustion Products: Materials that emit irritating combustion products. * Fire Conditions: Materials that under fire conditions, cause skin irritation, but not destruction of tissue. * Ingestion - Oral: Materials whose LDSO for acute oral toxicity is >500 milligrams and </=2,000 milligrams per kilogram [mg/kg]. * Skin: Materials whose LD50 for acute dermal toxicity is >1,000 milligrams and </=2,000 milligrams per kilogram [mg/kg]. * Dusts & Mists - Inhalation: Dusts & mists whose LC50 for acute inhalation toxicity is >10 and </=200 milligrams per liter [mg/Q. * Gases & Vapors -Inhalation: Gas & vapor whose LCSO for acute inhalation toxicity is >5,000 and </=10,000 parts per million [ppm]. * Irritant: Materials that are moderate respiratory irritants, or that cause slight to moderate eye irritation. KLAUSBRUCKNER & ASSOCIATES -2485 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 56 of 63 - - - - - - - - - - - - -. - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) 0: Materials that on exposure under fire conditions would offer no hazard beyond that of ordinary combustible materials - i.e.: * Ingestion - Oral: Materials whose LD50 for acute oral toxicity is >2,000 milligrams per kilogram [mg/kg]. * Skin: Materials whose LD50 for acute dermal toxicity is >2,000 milligrams per kilogram [mg/kg]. * Dusts & Mists - Inhalation: Dusts & mists whose LC50 for acute inhalation toxicity is >200 milligrams per liter [mg/L]. * Gases & Vapors -Inhalation: Gas & vapor whose LC50 for acute inhalation toxicity is >10,000 parts per million [ppm]. Flammability [Red]: Hazard rating of flammability hazards ranked according to the susceptibility of materials to burning as follow: 4: Materials that will rapidly or completely vaporize at atmospheric pressure and normal ambient temperature or that are readily dispersed in air, and which will burn readily -- i.e.: * Flammable Gases. * Flammable cryogenics. * Any liquid or gaseous material that is liquid while under pressure and has a flash point <73oF and a boiling point <1000F [i.e.: Class I-A Flammable Liquid]. * Materials that ignite spontaneously when exposed to air [i.e.: Pyrophorics]. 3: Liquids and solids that can be ignited under almost all ambient temperature conditions. Materials in this degree produce hazardous atmospheres with air under almost all ambient temperatures or, though unaffected by ambient temperatures, are readily ignited under almost all conditions -- i.e.: * Liquids having a flash point <730F and having a boiling point >/=100oF and those liquids having a flash point >/=73oF and <1000F [i.e.: Class I-B & I-C Flammable Liquids]. * Materials that on account of their physical form or environmental conditions can form explosive mixtures with air that are readily dispersed in air [i.e.: dusts of combustible/flammable solids, mists of flammable/combustible liquid droplets]. * Materials that burn with extreme rapidity, usually by reason of self-contained oxygen [i.e.: many Organic Peroxides, dry nitrocellulose]. 2: Materials that must be moderately heated or exposed to relatively high ambient temperatures before ignition can occur. Materials in this degree would not under normal conditions form hazardous atmospheres with air, but under ambient temperatures or under moderate heating may release vapor in sufficient quantities to produce hazardous atmospheres with air -- i.e. * Liquids having a flash point >1000F and </-200oF [i.e.: Class II & Class Ill-A CombUstible Liquids]. * Solid materials in the form of coarse dusts that may burn rapidly but that generally do not form explosive atmospheres with air [i.e.: Flammable Solids]. * Solid materials in a fibrous or shredded form that may burn rapidly and create flash fire hazards [i.e.: cotton, sisal, hemp]. * Solids and semisolids that readily give off flammable vapors. HAZARD RATING [DEGREES OF HAZARD] - continued Flammability [Red] - continued: 1: Materials that must be preheated before ignition can occur. Materials in this degree require considerable preheating, under all ambient temperature conditions, before ignition and combustion can occur -- i.e.: * Materials that will burn in air when exposure to a tempura of 1500oF for </5 minutes. * Liquids, solids & semisolids having a flash point >2000F [i.e.: Class Ill-B Combustible Liquids]. 0: Materials that will not burn -- i.e.: material that will not burn in air when exposed to a temperature of 1500oF for a period of 5 minutes. Reactivity/Instability [Yellow]: Hazard rating of reactivity [instability) hazards ranked according to ease, rate and quantity of energy release as follows: 4: Materials that in themselves are readily capable of detonation or explosive decomposition or explosive reaction at normal temperatures and pressures -- i.e.: * Materials sensitive to localized thermal or mechanical shock at normal temperatures and pressures. 3: Materials that in themselves are capable of detonation or explosive decomposition or explosive reaction, but that require a strong initiating source or that must be heated under confinement before initiation -- i.e.: * Materials sensitive to thermal or mechanical shock at elevated temperatures and pressures. * Materials that reactive explosively with water without requiring heat or confinement. 2: Materials that readily undergo violent chemical change at elevated temperatures and pressures -- i.e.: * Materials that exhibit an exotherm at temperatures </=1500C when tested by differential scanning calorimetry. KLAUSBRUCKNER & ASSOCIATES - 2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 57 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) Materials that may react violently with water or form potentially explosive mixtures with water. Materials that in themselves are normally stable, but that can become unstable at elevated temperatures and pressure -- i.e.: Materials that change or decompose on exposure to air, light or moisture. Materials that exhibit an exotherm at temperatures >1500C but <I=300oC when tested by differential scanning calorimetry. Materials that in themselves are normally stable, even under fire conditions -- i.e.: Materials that do not react with water. Materials that exhibit an exotherm at temperatures >3000C but </=5000C when tested by differential scanning calorimetry. Materials that do not exhibit an exotherm at temperature </=5000C when tested by differential scanning calorimetry. HAZARDOUS MATERIALS Chemicals or substances which are physical hazards or health hazards as defined and classified in IFCICFC Chapter 27, whether the materials are in usable or waste condition. HEALTH HAZARD A classification of a chemical for which there is statistically significant evidence that acute or chronic health effects are capable of occurring in exposed persons. The term 'health hazard' includes chemicals that are toxic, highly toxic and corrosive. HIGHLY TOXIC Material which produces a lethal dose or lethal concentration as follows: Oral Ingestion = LD50 = <1=50 mg/kg - Rat: Median lethal dose [LD50] of 50 milligrams of less per kilogram of body weight when administered orally to albino rats weighing between 200 and 300 grams each. Skin Absorption = LD50 = </=200 mg/kg - Rabbit: Median lethal dose [LD50] of 200 milligrams or less per kilogram of body weight when administered by continuous contact for 24 hours (or less if death occurs within 24 hours) with the bare skin of albino rabbits weighing between 2 and 3 kilograms each. Inhalation = LC50 = </=200 ppm - Rat: Median lethal concentration [LC50] in air of 200 ppm by volume or less of gas or vapor, or 2 milligrams per liter or less of mist, fume or dust, when administered by continuous inhalation for one hour (or less if death occurs within 1 hour) to albino rats weighing between 200 and 300 grams each. Mixtures of these materials with ordinary materials, such as water, might not warrant classification as highly toxic. Dot Class 6.1 Materials. INCOMPATIBLE MATERIALS Materials that, when mixed, have the potential to react in a manner which generates heat, fumes, gases, or byproducts which are hazardous to life or property. The maximum allowable quantity per control area is based on the material state (solid, liquid or gas) and the material storage or use conditions. IRRITANT A chemical which is not corrosive, but which causes a reversible inflammatory effect on living tissue by chemical action at the site of contact. A chemical is a skin irritant if, when tested on the intact skin of albino rabbits by the methods of CPSC 16CFR Part 1500.41 for an exposure of four or more hours or by other appropriate techniques, it results in an empirical score of 5 or more. A chemical is classified as an eye irritant if so determined under the procedure listed in CPSC 16CFR Part 1500.42 or other approved techniques. LIQUEFIED PETROLEUM GAS (LP-gas) KLAUSBRUCKNER & ASSOCIATES -2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 58 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) A material which is composed predominantly of the following hydrocarbons or mixtures of them: propane, propylene, butane (normal butane or isobutene) and butylenes. LOWER FLAMMABLE LIMIT (LFL) The minimum concentration of vapor in air at which propagation of flame will occur in the presence of an ignition source. The LFL is sometimes referred to as LEL or lower explosive limit. MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA (MAQ) The maximum amount of a hazardous material allowed to be stored or used within a control area inside a building or an outdoor control area. OCCUPANCY B Occupancy: Business Group B occupancy includes, among others, the use of a building or structure, or portion thereof, for office, professional or service-type transaction, laboratories (testing and research), and print shops. F Occupancy: Factory Industrial Group F occupancy includes, among others, the use of a building or structure, or a portion thereof, for assembling, disassembling, fabricating, finishing, manufacturing, packaging, repair or processing operations that are not classified as Group H high-hazard or Group S storage occupancy. F-I Moderate-hazard Occupancy: Includes, but not limited to, athletic equipment, automobiles, electronics, food processing, laundries, paper mills, printing and publishing, soaps and detergents, textiles and wood. F-2 Low-hazard Occupancy: Factory industrial uses involving the fabrication or manufacturing of noncombustible materials which, during finishing, packaging or processing do not involve a significant fire hazard. H Occupancy: High-hazard Group H occupancy includes, among others, the use of a building or structure, or a portion thereof, that involves the manufacturing, processing, generation or storage of materials that constitute a physical or health hazard in quantities in excess of quantities allowed in control areas constructed and located as required in Section 2703.8.3. H-2: >1= Maximum Allowable Quantity of one or more of the following Physical Hazard Materials: Class I, II or hA flammable or combustible liquids used or stored in normally open containers or systems, or in closed containers or systems pressurized at >15 psig. Combustible dust. Cryogenic fluids, flammable. Flammable gases. Class 1 organic peroxides. Class 3 oxidizers used or stored in normally open containers or systems, or in closed containers or systems pressurized at >15 psig. Pyrophoric liquids, solids and gases, nondetonable. Class 3 nondetonable unstable (reactive) materials. Class 3 water reactive materials. OCCUPANCY - continued H-3: >1= Maximum Allowable Quantity of one or more of the following Physical Hazard Materials: Class I, II or IlA flammable or combustible liquids used or stored in normally open containers or systems, or in closed containers or systems pressurized at >15 psig. Combustible fibers, other than densely packed baled cotton. Oxidizing Cryogenic fluids. Flammable solids. Class II and III Organic peroxides. Class 2 Oxidizers. Class 2 Oxidizers used or stored in normally open containers or systems, or in closed containers or systems pressurized at >15 psig. Class 2 unstable (reactive) materials. KLAUSBRUCKNER & ASSOCIATES - 2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 59 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) Class 2 water-reactive materials. H-4: >1= Maximum Allowable Quantity of one or more of the following Health Hazard Materials: Corrosives. Highly toxic materials. Toxic materials. M Occupancy: Mercantile Group M occupancy includes, among others, buildings and structures or a portion thereof, for the display and sale of merchandise, and involves stocks of goods, wares or merchandise incidental to such purposes and accessible to the public. S Occupancy: Storage Group S occupancy includes, among others, the use of a building or structure, or a portion thereof, for storage that is not classified as a hazardous occupancy. S-I Moderate-hazard storage: Includes, but not limited to, level 2 and 3 aerosols, books and paper in rolls or packs, cardboard boxes, clothing, glues, motor vehicle repair garages, and soaps. S-2 Low-hazard storage: Buildings used for the storage of noncombustible materials such as products on wood pallets or in paper cartons with or without single thickness divisions; or in paper wrappings. OPEN SYSTEM The use of a solid or liquid hazardous materials involving a vessel or system that is continuously open to the atmosphere during normal operations and where vapors are liberated, or the product is exposed to the atmosphere during normal operations. Examples: Dispensing from or into open beakers or containers. Dip tank and plating tank operations. ORGANIC PEROXIDE An organic compound that contains the bivalent -0-0- structure and which may be considered to be a structural derivative of hydrogen peroxide where one or both of the hydrogen atoms have been replaced by an organic radical. Organic peroxides can present an explosion hazard (detonation or deflagration) or they can be shock sensitive. Organic peroxides can decompose into various unstable compounds over an extended period of time. DOT 5.3 Materials. Unclassified Detonable Organic Peroxide: Organic peroxides that are capable of detonation. There peroxides pose an extremely high-explosion hazard through rapid explosive decomposition. Regulated as Class A explosive DOT Type A Class I Organic Peroxide: Formulations that are capable of deflagration but not detonation. DOT Type B Class II Organic Peroxide: Formulations that burn very rapidly and that pose a moderate reactivity hazard. DOT Type C Class Ill Organic Peroxide: Formulations that burn rapidly and that pose a moderate reactivity hazard. DOT Type D Class IV Organic Peroxide: Formulations that burn in the same manner as ordinary combustibles and that pose a minimal reactivity hazard. DOT Type E&F KLAUSBRIJCKNER & ASSOCIATES -2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 60 of 63 - - - - -. - - - - - - - - - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) ORGANIC PEROXIDE - continued Class V Organic Peroxide: Formulations the burn with less intensity than ordinary combustibles or do not sustain combustion and that pose no reactivity hazard. DOT Type G OTHER HEALTH HAZARD Hazardous material which affects target organs of both body including, but not limited to, those materials which produce liver damage, kidney damage, damage to the nervous system, act on the blood to decrease hemoglobin function, deprive the body tissue of oxygeTn, or affect reproductive capabilities including mutations [chromosomal damage] or teratogens [effects on fetuses]. OUTDOOR CONTROL AREA An outdoor area that contains hazardous materials in amounts not exceeding the maximum allowable quantities of Table 2703.1.1(3) or 2703.1.1(4). OXIDIZER A material that readily yields oxygen or other oxidizing gas, or that readily reacts to promote or initiate combustion of combustible materials and, if heated or contaminated, can result in vigorous self-sustained decomposition. Examples of other oxidizing gases include bromide, chlorine and fluorine. DOT Class 5.1 Materials. Class 4 Oxidizer: Can undergo an explosive reaction due to contamination or exposure to thermal or physical shock and that causes a severe increase in the burning rate of combustible materials with which it comes into contact. Additionally, the oxidizer causes a severe increase in the burning rate and can cause spontaneous ignition of combustibles. Acceptable Test Criteria - DOT Packaging Group I: Material which, in either concentration tested, exhibits a burning time equal to or less than that of potassium bromate. Class 3 Oxidizer: Will cause a severe increase in the burning rate of combustible materials with which it comes in contact. Acceptable Test Criteria - DOT Packaging Group II: Material, which, in either concentration tested, exhibits a burning time between that of potassium bromate and that of potassium perchlorate. Class 2 Oxidizer: Will cause a moderate increase in the burning rate of combustible materials with which it comes in contact. Acceptable Test Criteria - DOT Packaging Group III: Material, which, in either concentration tested, exhibits a burning time between that of potassium perchlorate and that of ammonium persulphate. Class 1 Oxidizer: Does not moderately increase the burning rate of combustible materials. pH Value used to represent the strength of an acid or base [alkali]: pH 1-<7: Acid [1=Strong; 6=Weak] pH 7: Neutral [i.e. Water] pH >7-14: Base [pH 11 = 10 times more corrosive than pH of 10] Skin: ph 6-8 KLAUSBRUCKNER & ASSOCIATES -2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER &ASSOC. - 2017-12-19 Page 61 of 63 - - - - -, - - - - - - - - - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Suite) PHYSICAL HAZARD A chemical for which there is evidence that it is a combustible liquid, cryogenic fluid, explosive, flammable (solid, liquid or gas), organic peroxide (solid or liquid), oxidizer (solid or liquid), oxidizing gas, pyrophoric (solid, liquid or gas), unstable reactive material (solid, liquid or gas) or water- reactive material (solid or liquid). PYROPHORIC A chemical with an auto-ignition temperature in air, at or below a temperature of 1300F. SENSITIZER Chemical that causes a substantial proportion of exposed people or animals to develop an allergic reaction in normal tissue after repeated exposure to the chemical. Chronic effect/reaction. STORAGE The keeping, retention or leaving of hazardous materials in closed containers, tanks, cylinders, or similar vessels; or vessels supplying operations through closed connections to the vessel. TOXIC MATERIAL Materials which produces a lethal dose or lethal concentration as follows: Oral Ingestion = LD50 = >50 mg/kg to 500 mg/kg - Rat: Median lethal dose [LD50] of more than 50 milligrams per kilogram, but not more than 500 milligrams per kilogram of body weight when administered orally to albino rats weighing between 200 and 300 grams each. Skin Absorption = LD50 = >200 mg/kg to 1,000 mg/kg - Rabbit: Median lethal dose [LD50] of more than 200 milligrams per kilogram of body weight when administered by continuous contact for 24 hours (or less if death occurs within 24 hours) with the bare skin of albino rabbits weighing between 2 and 3 kilograms each. Inhalation = LC50 = >200 ppm to 2,000 ppm - Rat: Median lethal concentration [LC50] in air of more than 200 ppm but not more than 2,000 ppm by volume of gas or vapor, or more than 2 milligrams per liter but not more than 20 milligrams per liter of mist, fume or dust, when administered by continuous inhalation for 1 hour (or less if death occurs within 1 hour) to albino rats weighing between 200 and 300 grams each. Mixtures of these materials with ordinary materials, such as water, might not warrant classification as toxic. DOT Class 6.1 Materials. UNSTABLE (REACTIVE) MATERIAL A material, other than an explosive, which in the pure state or as commercially produced, will vigorously polymerize, decompose, condense or become self-reactive and undergo other violent chemical changes, including explosion, when exposed to heat, friction or shock, or in the absence of an inhibitor, or in the presence of contaminants, or in contact with incompatible materials. Unstable (reactive) materials are subdivided as follows: Class 4 Unstable (Reactive): Capable of detonation, explosive decomposition or explosive reaction at NTP. Materials that are sensitive to mechanical or localized thermal shock at NIP. Class 3 Unstable (Reactive): KLAUSBRUCKNER & ASSOCIATES -2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS - KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 62 of 63 - - - - - - - - - - - - - - - - - - - HAZARDOUS MATERIALS DEFINITIONS Bio-Rx - 1819 Aston Ave., Suite 104, Carlsbad, CA - Control Area (Entire Capable of detonation, explosive decomposition or explosive reaction but which require a strong initiating source or which must be heated under confinement before initiation. Materials that are sensitive to thermal or mechanical shock at elevated temperature and pressures. Class 2 Unstable (Reactive): Normally unstable and readily undergo violent chemical change but do not detonate. Materials that can undergo chemical change with rapid release of energy at NTP. Materials that can undergo violent chemical change at elevated temperatures and pressures. Class 1 Unstable (Reactive): Materials that are normally stable but which can become unstable at elevated temperature and pressures. USE (MATERIAL) . Placing a material into action, including solids, liquids and gases. WATER REACTIVE MATERIAL A material that explodes; violently reacts; produces flammable, toxic or other hazardous gases; or evolves enough heat to cause auto-ignition or ignition of combustibles upon exposure to water or moisture. DOT Class 4.3 Materials. Class 3 Water Reactive: Materials that react explosively with water without requiring heat or confinement. Class 2 Water Reactive: Materials that react violently with water or have the ability to boil water. Materials that produce flammable, toxic or other hazardous gases, or evolve enough heat to cause auto-ignition or ignition of combustibles upon exposure to water or moisture. Class 1 Water Reactive: Materials that react with water with some release of energy, but not violently. KLAUSBRUCKNER & ASSOCIATES -2495 TRUXTUN ROAD, SUITE 205, SAN DIEGO, CA 92106- TEL (619) 677-2004; FAX (619) 677-2444 HAZARDOUS MATERIALS/OCCUPANCY CLASSIFICATION ANALYSIS -KLAUSBRUCKNER & ASSOC. - 2017-12-19 Page 63 of 63