Loading...
HomeMy WebLinkAbout1836 COTTONWOOD AVE; ; CB900871; PermitBUILDING PERMIT 05/29/90 16.07 1 of 1 Parcel No. 215-503-37-10 Valuation 1,218 Construction Type NEW Permit No CB900871 Project No A9000971 Development No Ste 5780 05/29/90 0001 01 02 C-PRMT 52=00 SF PATIO COVER PER SPECS Status. ISSUED Applied : 05/29/90 Apr/Issue Validated By. DC OWNER TOOMBS, JIM *** Fees Required ****** Lie . Fees Collected & Credits * * * Fees Adjustments. Total Fees Fee description Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL 52 00 .00 52. 00 Total Credits Total Payments Balance Due• Units Fee/Unit . 00 00 52.00 Ext fee Data 31 00 20 00 1 00 52 00 •IIWAPPROVAL INSP. CLEARANCE CITY OF CARLSBAD 2075 Las Pataas Dr, Carlsbad CA 92009 (619) 438-1161 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr , Carlsbad, CA 92009 (eis) 438-nei [ PERMIT TYPE "A fj COMMERCIAL QNEW B D INDUSTRIAL DNEW c ^RESIDENTIAL DAPARTMENT DDUPLEX DDEMOLITION ORELOCATION QMOBILE HOME nELECTRICAL DPLL|MBING QTENANT IMPROVEMENT QTENANT IMPROVEMENT CONDO QSINGLE FAMILY DWELLING QADDITION/ALTERATION EST PLAN VALID DATE _^ . VAL /^7 / 6 CK DEPOSIT BY fo C__- _s y^/*^? /ps' f / S QMECHANICAL QSPA DETAINING WALL QSOLAR OOTHER NX'/ / 2 PROJECT INFORMATION PLAN CHECK No rfi) ~*® / / Address j*~> ^-* ~Y~***. i /\ A 1 ' Building or Suite No Nearest Cross Streets FOR OFFICE USE ONLY LEGAL DESCRIPTION Lot No Subdivision Name/Number Unit No Phase No . /O 'PjS-SS S^Po£T lyjCUVS / CHECK BELOW IF SUBMITTED CU Energy Calcs Q2 Structural Calcs Q2 Soils Report Q1 Addressed Envelope ASSESSOR'S PARCEL EXISTING USE DESCRIPTION1 01- USRK _ C^pv'T »O> (2OVEI-i£- BLDG SO ?TG (9-C?2> S*^- "*— "^" * °F STORIES / PROPOSED USE 3. CONTACT PERSON ADDRESS ZIP CODE iA/ooO DAY TELEPHONE - -B (3. *7 SIGNATURE ^JASV^"* — r^\ / /7 fTTY^1*^ - 4 5 6. 7 APPL^ICML, ncONTRCcjfl.r C.TY cS&L5g,A^O PROPERTY OWNER . _ CITY CA<LL"St^AO CONTRACTOR NAME CITY STATE LIC # SIGNATURE DESIGNER NAME CITY WORKERS' COMPENSATION O AGENT FOR CONTRACTOR Q^WNER ADDRESS ' STATE C A ZIP CODE Q e^-O< OWNER ADDRESS STATE 0/1 Z1P COOE 7 ^fc'C ADDRESS STATE ZIP CODE LICENSE CLASS TITLE ADDRESS STATE ZIP CODE Q AGENT FOR OWNER 35 f DAY TELEPHONE y /B/^L " 25 / 1 DLESSEE [^TENANT > ^ DAY TELEPHONE ^j O 3-~<-^e^' ' -5i DAY TELEPHONE CITY BUSINESS LIC # DATE DAY TELEPHONE STATE LIC # or a certificate of Workers' Compensation Insurance by an acknitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab C) INSURANCE COMPANY POLICY NO EXPIRATION DATE Certificate of Exemption I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California SIGNATURE DATE 8 OWNER-BUILDER DECLARATION Owner Builder Declaration I hereby affirm that I am exempt from the Contractor's License Law for the following reason I I I as ownpr of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 70^, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale ) n I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 70W, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) II I am exempt under Section Business and Professions Code for this reason SIGNATURE DATE COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act' DYES Quo Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 DYES DNO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' DYES QNO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1. 1989 UNLESS THE APPLICANT HAS NET OR IS MEETING THE REQUIREMENTSOF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(1) Civil Code) LENDER'S NAME LENDER'S ADDRESS 10 APPLICANT'S SIGNATURE I certify that I have read the appl icat i^rfarfd state that the above/nformat/on is correct I agree to^omply with all City ordinances and State laws relating to building construction 1 hereby aupfmriat representatives of thefCi tvj»/Carlsbad to enter upon th^ft>ovc mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARM^ESVTHE CITY OF CARLSBAD AGAlSSTALL LIABILITIES JUDGMENTS. COSTS AND EXPENSES WHICH NAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT Expiration Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Buildma Code) APPLICANT'S SIGNATURE OWNER Q] CONTRACTOR BY PHONE APPROVED BY BATE WHITE File YELLOW Applicant PINK Finance CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB900871 FOR 06/14/90 DESCRIPTION: 203 SF PATIO COVER PER SPECS TYPE: RAD JOB ADDRESS: 1836 COTTONWOOD AV APPLICANT: TOOMBS, JAMES CONTRACTOR: OWNER: TOOMBS, JIM INSPECTOR AREA MP PLANCK# CB900871 OCC GRP CONSTR. TYPE NEW STR: FL: STE: PHONE: 619 482-3293 PHONE: PHONE: REMARKS: Tl/CMW/JIM/438-0261 INSPECTOR SPECIAL INSTRUCT: WILL CALL TO SET UP TIME TOTAL TIME: CD LVL DESCRIPTION 15 ST Roof/Reroof ACT COMMENTS -3£ ***** INSPECTION HISTORY ***** DATE DESCRIPTION 061290 Final Structural 060890 Final Structural ACT INSP COMMENTS NR MP NOBODY HOME NR MP NOBODY HOME/NO ACCESS 04/29/91 INSPECTION HISTORY LISTING FOR PERMIT* CB900871 DATE INSPECTION TYPE 06/14/90 Roof/Reroof 06/14/90 Roof/Reroof 06/12/90 Final Structural 06/12/90 Final Structural 06/08/90 Final Structural 06/08/90 Final Structural INSP ACT COMMENTS RI RI Tl/CMW/JIM/438-0261 MP CO A-35 ON RAFTER-FACIA RI RI Tl/MH/JIM/438-0261 MP NR NOBODY HOME RI RI T3/MH/JIM/438-0261 MP NR NOBODY HOME/NO ACCESS HIT <RETURN> TO CONTINUE... JAMES M. TOCMBS JR LORI SKINNER TOOMBS 1836 CXDTTONWOOD AVENUE CARLSBAD, CA 92009 (619) 438-0261 MAY 22, 1990 DEAR SEAPORT HOMEOWNERS ASSOCATION, WE ARE REQUESTING YOUR APPROVAL FOR THE PATIO COVER WE HAD CONSTRUCTED AND NEED TO KNOW IF IT MEETS YOUR APPROVAL & MEETS ALL REQUIREMENTS OF THE CC&R'S. THANK YOU FOR YOUR PROMPT ATTENTION TO THIS MATTER ! SINCERELY, JAMES M. TOOMBS & LORI SKINNER TOOMBS ENCLOSED IS A PHOTO COPY OF OUR HOME IMPROVEMENT TO MEET YOUR APPROVAL. 2075 LAS PALMAS DRIVE CARLSBAD. CA 92009-4659 I TYPICAL FRAMING DETAILS ARE SHOWN BELOW MIN 1804 U'TVTt 10 1ST HANOI* LEOSER TO MOUSE ATTACHMENT CONTINUOUS SOLID BLOCKING BETWEEN JOISTS HOPE THAN 8 IN DEPTH Pott Cep 4x4 Brace W/1/2 OOltl •I 6 > J* ITIIl *T* JT«»P H/IOO NAILS AT 2" 0 C MAX 1/2* »LT»flOO 24*tlOI I 16* k.o«« ALTERNATE BRACING DETAILS Elevnted Pott Baee 1/2" q* 10- Anchor Bolt NATURAL SHADE I t/4'i • »000 CONTACTS MASONRY o* TYP ANCHOR AND FOOTING DETAILS FOR AMC«OR«SE TO EXISTING SLAtS USE t" StEEvt TYPE ANCxORS »iTn EXPANSION INSERT TELEPHONE (619)4381161 KOOP LIVILOAO • 10p»< MOOV DiAO^-OAD • 7 ptf ALL LUMBER TO 86 DOUGLAS PlM/LARCH NO 3 Oft BCTTCR RAPTER SPANIft ) 6 7 8 9 10 11 12 13 14 IS 16 17 18 19 20 POSTSPACINC(Ft ) 10 12 14 16 18 2O MINIMUM RAFTER SIZES RAFTER SPACING (CENTER TO CENTER) 12"16 4 4 4" 4* • I 2x4 2x4 2 ic 4 2 « 4" • 2 » 4* • 2 « 4 2x4 2x4 2x4' 2x6 2x8 2x8 2x8 2x8 2x8 2x8 2x8 2x10 2x10 2x10 MINIMUM BEAM SIZES RAFTER SPAN (Ft ) 8 10 12 14 18 20 4x4 | 4x4 • 4x4 ' 4x4 1 4x4 , 4x4 4x4 4x4 4x4 ' 4x4 j 4x4 , 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x6 ££*&<? 4x6 4x6 4x6 4x8 4x6 .4x6 4x6 4x6 | 4x8 4x8 4x8 ! 4x8 4x6 ' 4x6 . 4x8 . 4x8 , 4x8 4x10 4x6 4x8 4x8 4x8 ,4x8 4x8 4x10 4x10 4x10 4x8 I 4x8 i 4x10 4x10 4x10i 4x10 4x10 4x12 4x10; 4x10l 4x10 4x10 4x12' 4x12 4x12 4x12 4x101 4x10[ 4.12 .'4x12 4x12 4x12.4x14 4x14 MINIMUM SQUARE FOOTING SIZES dnch«ff" POSTSPAC ING 10 12 14 16 18 20 RAFTER SPAN (Ft ) 12- 12' 14 14 16 16 18 20 20 12' 12- 14 16 16 18 20 ao 22 10 j 12 | 14 | 16 16 18 20 18 18 i 20 20 20 22 20 22 ' 22 20 22 24 24 24 24 24 27 24 27 27 18 18 20 22 24 27 27 30 20 14 16 20 22 24 24 27 30 30 SM p«r»8r«Ph on pott tnchorag* (Spaelttcttiont on otMr fid* ) After prolonged period* of tlm« 2x4 r*fttrt •panning ov«r 8 ran may deflect permanently and give an objectionable appearance It li therefore recommended that for rafter ipant exceeding 8 feet a minimum rafter die of 2 x 6 be u»ed See dimennon A on Anchor end Footing Deullt 7-75 PATIO COVERS - DETAILS & SPAN TABLES BID- 105 gs n171 n j 5J UJ I/1 0 T! H o nD ni o R-p; 40" I