HomeMy WebLinkAbout1838 MARRON RD; ; CB030723; Permit09-02-2003
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB030723
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
1838 MARRON RD CBAD
Tl Sub Type:
Lot#:
$498,300.00 Construction Type:
Reference #:
DOLLAR TREE
16,610 SF TENANT IMPROVEMENT
COMM
0
NEW
Applicant:
BURDON CAROL
STE 100
5145 GOLDEN FOOTHILL PKWY
NORWALK 95762
Owner:
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
ISSUED
03/11/2003
MDP
09/02/2003
09/02/2003
3101 09/02/03 0002 01 02
CGP 2051-12
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Reel. Water Con. Fee
$1,775.48 Meter Size
$0.00 Add'l Reel. Water Con. Fee
$1,154.06 Meter Fee
$0.00 SDCWA Fee
$0.00 CFD Payoff Fee
$104.64 PFF
$0.00 PFF (CFD Fund)
$0.00 License Tax
$0.00 License Tax (CFD Fund)
$0.00 Traffic Impact Fee
$0.00 Traffic Impact (CFD Fund)
$0.00 PLUMBING TOTAL
$0.00 ELECTRICAL TOTAL
$0.00 MECHANICAL TOTAL
$0.00 Master Drainage Fee
Sewer Fee
$0.00 Redev Parking Fee
$0.00 Additional Fees
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$69.00
$20.00
$82.00
$0.00
$0.00
$0.00
$0.00
$3,205.18
Total Fees:$3,205.18 Total Payments To Date: $1,154.06 Balance Due: $2,051.12
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have oreviouslv been aiven a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
ERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
IAdi
PROJECT TION
u^T-S -fffiTA T^llfl/L "7%^
FOR OFFICE USE ONLY
PLAN CHECK
EST. VAL.
Plan Ck. Deposit If ((
Validated By.
Date
Idress (include Bldg/Suite #)Business Name (at this address)
Legal Description Lot No.Subdivision Name/Number .06
Assessor's Parcel #Existing Use T^\
V,
Proposed Use
of Work SQ. FT.#of Stories # of Bedrooms # of Bathrooms
Name Address
APPLICANT f Agent for Contractor Q Owner3/1, mi
City
(Agent for Owner
State/Zip Telephone # Fax #
>«
(LA
Name
*, _ PROPBBTY OWNERP/uO matte.
Address City State/Zip Telephone #
R D/L
State/Zip Telephone #Name Address City
6. CONTRACTOR - COMPANY NAME
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
Name
State License *X&-
if
Address
License ClassX
QU/J -
City State/Zii
City Business License #
Telephone #
2X5/0- 75 7-
Designer Name 7 / Address' / ' City State/Zip Telephone
State License #
8, WORKERS'COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
l~l I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
l~l I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are: 1^/C ?3f)$6>0&, -03 CflQ&J
Insurance CompanyfaZ.tJ&iCtf Policy No. &tC-?tfl£f)#fa -/tTLJA/J) Expiration Date % IrOj ~
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
l~l CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE DATE
?, OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
n If as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
[~| I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
|~l I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. l~l YES I~|NO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number): _____
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work): _____
PROPERTY OWNER SIGNATURE DATE
t»MwjteTMittttM^
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? [_] YES fj] NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? l~) YES CD NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES d NO
IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
8, CONSTRUCTION LENDING AGENCY ':::v :•••••.•.;•;:r•• : '• •. : ' :v:::f;; • ^/ -^:.•••":• ,' :::^:::':/..yy':-:;- :• ; ::
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 30970) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
9, APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenced for a period of ISj^laysJSection 106.4.4 Uniform Building Code).
APPLICANT'S SIGNATURE /feg^^X^^/i /€&>&&—^ DATE
•^ WHITE: File YELLOW: Applicant PINK: Finance
CttyilCirlsbad
Final Building inspection
Dept: Building Engineering Planning CMWD St Lite
Plan Check*:
Permit #:
Project Name:
Address:
Contact Person:
Sewer Dist:
Inspected^
By: L£- 3
Inspected
Bv:
Inspected
By:
CB030723
DOLLAR TREE
16,610 SF TENANT IMPROVEMENT
1838MARRONRD
NA Phone: 3105058915
Water Dist:
-^ / ^ Date /'//^/f'z>-O/^f^A-x' inspected:
Date
Inspected:
Date
Inspected:
Date:
Permit Type:
Sub Type:
Lot: 0
L^'
Approved:
Approved:
Approved:
10/17/2003
Tl
COMM
^
Disapproved:
Disapproved:
Disapproved:
Comments:
City of Carlsbad Bldg Inspection Request
For: 10/23/2003
Permit* CB030723
Title: DOLLAR TREE
Description: 16,610 SF TENANT IMPROVEMENT
Inspector Assignment: TP
Type: Tl Sub Type: COMM
Job Address: 1838MARRONRD
Suite: Lot 0
Location:
APPLICANT BURDON CAROL
Owner:
Remarks:
Phone: 3105058915
Inspector:
Total Time:Requested By: NA
Entered By: CHRISTINE
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Act Comment
AP
CV030162
CV030756
Date
10/17/2003
10/14/2003
10/14/2003
10/14/2003
10/14/2003
10/14/2003
10/10/2003
10/10/2003
10/10/2003
10/07/2003
10/01/2003
10/01/2003
09/29/2003
09/26/2003
09/25/2003
Associated PCRs/CVs
CLOSED Z- BANNER;
OPEN Z- BANNER AT NEW BIZ;
Inspection History
Description
89 Final Combo
Act
nbo CO
mbing CO
lectric AP
lectric AP
ctrical WC
ucts/Dampers AP
teel/Bolting/Welding AP
opout WC
'ucts/Dampers PA
lectric NR
teel/Bolting/Welding WC
lectric AP
.ath/Drywall AP
.ath/Drywall NS
.ath/Drywall CA
Insp
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
Comments
SEE ATTACHED NOTICE
T-24 ISSUES @ R.R.
GONDOLA BASES, POWER POLES, MGR OFFICE
ADD CIR TO PNLS
F.D. @ 1HRWALL
T-CEIL @ SALES
F.DMPRS
NOT COMP.
CEIL LITES (SEE CARD)
CONT LEFT, RE-SCHED
City of Carlsbad Bldg Inspection Request
For: 10/17/2003
Permit* CB030723
Title: DOLLAR TREE
Description: 16,610 SF TENANT IMPROVEMENT
Inspector Assignment: TP
Type:TI Sub Type: COMM
Job Address: 1838 MARRON RD
Suite: Lot o
Location:
APPLICANT BURDON CAROL
Owner:
Remarks:
Phone: 3105058915
Inspector:
Total Time:Requested By: NA
Entered By: CHRISTINE
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Act Comment
Date
10/14/2003
10/14/2003
10/14/2003
10/14/2003
10/14/2003
10/10/2003
10/10/2003
10/10/2003
10/07/2003
10/01/2003
10/01/2003
09/29/2003
09/26/2003
09/25/2003
09/24/2003
Associated PCRs/CVs
CLOSED Z- BANNER;
OPEN Z- BANNER AT NEW BIZ;
Inspection History
Description
CV030162
CV030756
Act
mbing CO
lectric AP
lectric AP
ctrical WC
'ucts/Dampers AP
teel/Bolting/Welding AP
opout WC
'ucts/Dampers PA
lectric NR
teel/Bolting/Welding WC
lectric AP
.ath/Drywall AP
ath/Drywall NS
.ath/Drywall CA
.ath/Drywall CO
Insp
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
Comments
T-24 ISSUES @ R.R.
GONDOLA BASES, POWER POLES, MGR OFFICE
ADD CIR TO PNLS
F.D. @ 1HRWALL
T-CEIL @ SALES
F.DMPRS
NOT COMP.
CEIL LITES (SEE CARD)
CONT LEFT, RE-SCHED
CITY OF CARLSBAD
BUILDING DEPARTMENT
NOTICE (760) 602-2700
1635 FARADAY AVENUE
DATE
LOCATION.LJU.
PERMIT NO.
TIME
/)
>A/, /A / /-
J-
FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE?
FOR FURTHER INFORMATION, CONTACT <^'/-/ ?^ V
? I _ I YES
PHONE
BUILDING INSPECTOR CODE ENFORCEMENT OFFICER
Carlsbad 03-723
7/25/03
EsGil Corporation
In Partnership voith government for Quitting Safety
DATE: 7/25/03 a APPt4£ANT
JURISDICTION: Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: O3-723 SET: III
PROJECT ADDRESS: 1838 Marron Rd.
PROJECT NAME: Dollar Tree TI
™ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
EH The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
EJ The applicant's copy of the check list has been sent to:
™ Esgil Corporation staff did not advise the applicant that the plan check has been completed.
EH Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
B REMARKS: Revised sheet M3 at the city must be inserted into the latest set of plans at
the city to make an approved 2nd set of plans.
By: Chuck Mendenhall Enclosures:
Esgil Corporation
D GA D MB D EJ D PC Phone In tmsmtl.dot
EsGil Corporation
In {Partnership with (government for 'Building Safety
DATE: 7/24/03 a APELJCANT
JURISDICTION: Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: 03-723 SET: III
PROJECT ADDRESS: 1838 Marron Rd.
PROJECT NAME: Dollar Tree TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
J The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Cederquist, Rodriguez, Ripley Architects
129 W. Virginia Beach Blvd. Norfolk, VA 23510
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Cristopher Coriell Telephone #: (757) 622-2828
Date contacted: ? /2^/o3 (by: farf Fax #: (757) 622-6883
Mail "Telephone Fax--' In Person
REMARKS:
By: Chuck Mendenhall Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 7/17/03 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 41 Fax (858) 560-1576
Carlsbad O3-723
7/24/03
Please make all corrections on the original tracings, as requested in the
correction list. Submit three sets of plans for commercial/industrial projects
(two sets of plans for residential projects). For expeditious processing,
corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the
City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA
92008, (760) 602-2700. The City will route the plans to EsGil Corporation
and the Carlsbad Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123,
(858) 560-1468. Deliver all remaining sets of plans and calculations/reports
directly to the City of Carlsbad Building Department for routing to their
Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until
review by EsGil Corporation is complete.
The items listed below are from the previous correction list. These
remaining items have not been adequately addressed. The numbers
of the items are from the previous check list and may not necessarily
be in sequence.
THE RESPONSES INDICATED THAT A REVISED SHEET A-4 WAS TO
BE PROVIDED TO ADDRESS ITEMS 1 & 4 BELOW THERE WAS NO
REVISED SHEET A-4 WITH THE RESUBMITTAL. THE ONLY REVISED
SHEET PROVIDED WAS SHEET M3.
1. Include as part of the section view of all new interior partitions. Show:
a) Method of attaching top and bottom plates to structure. (NOTE: Top
of partition must be secured to roof or floor framing, unless
suspended ceiling has been designed for partition lateral load).
Wall detail 2/A4 shows no lateral support for the top of the
wall. WHAT IS THE SPACING OF THE KICKERS SHOWN IN
DETAIL 2/A4? WHAT IS THE SPACING OF THE 18GA. STUDS
EXTENDING TO THE ROOF? WHY DOES THE SAME DETAIL,
2/A4, INDICATE THE STUDS ARE 20GA. @ 16" OC? WHAT IS
THE HEIGHT OF THE ROOF? THE MAX UNSUPPORT HEIGHT
FOR THE 18GA. STUDS IS 17FT @ 16" OC AND 15FT FOR
18GA STUDS @ 24" OC
MECHANICAL (2000 UNIFORM MECHANICAL CODE)
4. On the mechanical plans clearly show the limits of ceiling space used as
duct or plenum. Then address the following on the plans: THE AREA OF
Carlsbad 03-723
7/24/03
THE PLENUM APPEARS TO END AT THE STOCK ROOM WALL.
HOWEVER, DETAIL 2/A4 SHOWING THE STOCK ROOM WALL
CONSTRUCTION DOES NOT SHOW A BARRIER EXTENDING ABOVE
THE DROPPED CEILING TO DEFINE THE RA PLENUM.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail
number, calculation page, etc.
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone
number of 858/560-1468, to perform the plan review for your project. If
you have any questions regarding these plan review items, please contact
Chuck Mendenhall at Esgil Corporation. Thank you.
EsGii Corporation
Q AEPUGANT
Q PLAN REVIEWER
a FILE
In Partnership with government for (BuiCifity Safety
DATE: 6/10/03
JURISDICTION: Carlsbad
PLAN CHECK NO.: 03-723 SET: II
PROJECT ADDRESS: 1838 Marron Rd.
PROJECT NAME: Dollar Tree TI
|~~1 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
•i The applicant's copy of the check list has been sent to:
Cederquist, Rodriguez, Ripley Architects
129 W. Virginia Beach Blvd, Norfolk, VA 23510
I | Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Cristopher Coriell
Date contacted: u>( i j /o3 (by: £A*)
Mail ---Telephone Fax~^ In Person
REMARKS:
By: Chuck Mendenhall
Esgil Corporation
D GA D MB D EJ PC 6/3/03
Telephone #: (757) 622-2828
Fax #: (757) 622-6883
Enclosures:
trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576
Carlsbad O3-723
6/1O/O3
Please make all corrections on the original tracings, as requested in the
correction list. Submit three sets of plans for commercial/industrial projects
(two sets of plans for residential projects). For expeditious processing,
corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the
City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA
92008, (760) 602-2700. The City will route the plans to EsGil Corporation
and the Carlsbad Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123,
(858) 560-1468. Deliver all remaining sets of plans and calculations/reports
directly to the City of Carlsbad Building Department for routing to their
Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until
review by EsGil Corporation is complete.
The items listed below are from the previous correction list. These
remaining items have not been adequately addressed. The numbers
of the items are from the previous check list and may not necessarily
be in sequence.
1. Include as part of the section view of all new interior partitions. Show:
a) Method of attaching top and bottom plates to structure. (NOTE: Top
of partition must be secured to roof or floor framing, unless
suspended ceiling has been designed for partition lateral load).
Wall detail 2/A4 shows no lateral support for the top of the
wall. WHAT IS THE SPACING OF THE KICKERS SHOWN IN
DETAIL 2/A4? WHAT IS THE SPACING OF THE 18GA. STUDS
EXTENDING TO THE ROOF? WHY DOES THE SAME DETAIL,
2/A4, INDICATE THE STUDS ARE 20GA. @ 16" OC? WHAT IS
THE HEIGHT OF THE ROOF? THE MAX UNSUPPORT HEIGHT
FOR THE 18GA. STUDS IS 17FT @ 16" OC AND 15FT FOR
18GASTUDS @24"OC
MECHANICAL (2000 UNIFORM MECHANICAL CODE)
4. On the mechanical plans clearly show the limits of ceiling space used as
duct or plenum. Then address the following on the plans: THE AREA OF
THE PLENUM APPEARS TO END AT THE STOCK ROOM WALL.
HOWEVER, DETAIL 2/A4 SHOWING THE STOCK ROOM WALL
CONSTRUCTION DOES NOT SHOW A BARRIER EXTENDING ABOVE
THE DROPPED CEILING TO DEFINE THE RA PLENUM.
Carlsbad 03-723
6/10/03
5. THERE WAS NO NOTE ON THE PLANS DESCRIBING THE EXPOSED
MATERIALS USED IN THE PLENUM. THE NOTES BELOW MUST BE
INCLUDED ON THE PLANS. ALSO, THE NEW WATER LINES WITHIN
THE CEILING PLENUM MAY NOT BE WRAPPED WITH 1" EXPOSED
FIBERGLASS AS INDICATED IN PLUMBING NOTE 6 ON M-3. THE
EXPOSED FIBERGLASS WRAP MAY NOT BE USED FOR THE SHEET
METAL DUCTS AS INDICATED IN NOTE 5 HVAC NOTES ON M3.
FINALLY THE CONDENSATE LINES WITHIN THE PLENUM MAY NOT
BE PLASTIC PIPE
a) Clearly show that all material exposed within the plenum complies
with UMC Section 601.4. "Materials shall have a mold-, humidity-,
and erosion-resistant face that meets the requirements of UL 181."
b) Clearly show that all combustible materials exposed within the
plenum space must comply with UMC Section 602.2. Flame-
spread index of not more than 25 and a smoke-developed rating of
not more than 50.
c) A combustion products vent, vent connector, chimney, or chimney
connector shall not extend into or through an air duct or plenum.
UMC Section 804.0.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail
number, calculation page, etc.
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone
number of 858/560-1468, to perform the plan review for your project. If
you have any questions regarding these plan review items, please contact
Chuck Mendenhall at Esgil Corporation. Thank you.
EsGil Corporation
In Partnership with (government for Quitting Safety
DATE: 3/21/03 a AegUGANT
JURISDICTION: Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: 03-723 SET: I
PROJECT ADDRESS: 1838 Marron Rd.
PROJECT NAME: Dollar Tree TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Cederquist, Rodriguez, Ripley Architects
1 29 W. Virginia Beach Blvd. Norfolk, VA 2351 0
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted: Cristopher Coriell Telephone #: (757) 622-2828
Date contacted: 3>/2-i/°3 (by: \<~- ) Fax #: (757) 622-6883
Mail telephone Fax^ In Person
REMARKS:
By: Chuck Mendenhall Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 3/13/03 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576
Carlsbad 03-723
3/21/03
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 03-723 JURISDICTION: Carlsbad
OCCUPANCY: M USE: Retail Store
TYPE OF CONSTRUCTION: VN ACTUAL AREA: 16610 TI
ALLOWABLE FLOOR AREA: No change STORIES: No change
HEIGHT: no change
SPRINKLERS?: yes OCCUPANT LOAD: 492
REMARKS:
DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY
JURISDICTION: ESGIL CORPORATION: 3/13/03
DATE INITIAL PLAN REVIEW PLAN REVIEWER: Chuck MendenhaU
COMPLETED: 3/21/03
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list for a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot
Carlsbad 03-723
3/21/03
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. Include as part of the section view of all new interior partitions. Show:
a) Method of attaching top and bottom plates to structure. (NOTE: Top of
partition must be secured to roof or floor framing, unless suspended
ceiling has been designed for partition lateral load). Wall detail 2/A4
shows no lateral support for the top of the wall.
2. Specify lever-type hardware for passage doors on floors accessible to the
disabled. Title 24.
3. Note on the plans: that exit door 402 is openable from inside without the use of a
key or special knowledge.". Section 1003.3.1.8. See the schedule on sheet A4.
• PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
4. Show that water heater is adequately braced to resist seismic forces. Provide
two straps. One strap at top 1/3 of the tank and one strap at bottom 1/3 of the
tank. UPC, Section 510.5
5. Detail required drain pan under water heaters and 3A inch drain line to an
approved location, for water heaters located in an attic, attic/ceiling assembly,
floor/ceiling assembly, or floor/subfloor assembly where damage may result from
a leaking water heater, as per UPC Section 510.7
6. Detail required ladder access to water heaters more than 8 feet above the floor.
UPC section 511.2. "
Carlsbad O3-723
3/21/03
7. Show P & T valve on water heater and detail drain line route from P & T valve to
the exterior. UPC Section 608.5
8. Show 1/4 inch per 12 inch slope on drain and waste lines. UPC Section 708.0
9. Detail how bath room floor drain trap seal is to be maintained. UPC Section
1007.0 (floor drain trap primers).
MECHANICAL (2000 UNIFORM MECHANICAL CODE)
10. Detail disposal sites of main condensate drainage from air conditioning units.
UMC Section 310.1 & UPC 807.2.
11. Provide smoke detection in the supply air duct of an "air-moving system" for
required shut-off of equipment for smoke control. UMC Section 609.2.
• An "air-moving system" is a system designed to provide heating, cooling,
or ventilation in which one or more air-handling units are used to supply air to
a common space or to draw air from a common plenum or space. UMC
Section 203.0.
12. On the mechanical plans clearly show the limits of ceiling space used as duct or
plenum. Then address the following on the plans:
a) Clearly show that all material exposed within the'plenum complies with
UMC Section 601.4. "Materials shall have a mold-, humidity-, and
erosion-resistant face that meets the requirements of UL 181."
b) Clearly show that all combustible materials exposed within the plenum
space must comply with UMC Section 602.2. Flame-spread index of not
more than 25 and a smoke-developed rating of not more than 50.
c) A combustion products vent, vent connector, chimney, or chimney
connector shall not extend into or through an air duct or plenum. UMC
Section 804.0.
• ENERGY CONSERVATION
13. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section
131(d). (5,000 square foot exemption has been eliminated-AB 970 energy design
change)
DISABLED ACCESS REVIEW LIST
• REMODELS. ADDITIONS AND REPAIRS
• When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to
Carlsbad O3-723
3/21/O3
comply with all of the requirements for new buildings, per Section 1134B.2. These
requirements apply as follows:
a) The area of specific alteration, repair or addition must comply as "new"
construction.
b) A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features.
Provide a site plan showing the location of the disabled accessible parking
serving this remodel as follows:
14. Each lot or parking structure where parking is provided for the public, as clients,
guests or employees, shall provide accessible parking as required by Section
1129B.
15. Show on the site plan the required number of accessible parking spaces for new
facilities. Per Table 11B-7 the minimum number of spaces is:
a) 1 for each 25 spaces up to 100 total spaces.
b) 1 additional space for each 50 spaces for between 101 and 200 total
spaces.
c) 1 additional space for each 100 spaces for between 201 and 500 total
spaces.
1.6. Show that accessible parking spaces comply with Section 1129B.4.1 as follows:
a) Single spaces shall be 14' wide and outlined to provide a 9' parking area
and a 5' loading and unloading area on the passenger side of the vehicle.
b) When more than one space is provided, in lieu of providing a 14' space for
each space, two spaces can be provided within a 23' area with a 5' loading
zone between each 9'0" wide space.
c) Each space is to be a minimum of 18' in depth.
17. At least one in every 8 accessible parking spaces shall be served by an access
aisle >96" in width and designated as VAN ACCESSIBLE, per Section 1129B.4.2.
18. The words "NO PARKING" shall be painted on the ground within each 8' loading
and unloading access aisle (in white letters no less than 12" high and located so
that it is visible to traffic enforcement officials). Section 1129B.4.2.
19. Show or note on the plans that the accessible parking spaces are to be identified
by a reflectorized sign, permanently posted immediately adjacent to and visible
from each space, consisting of:
a) A profile view of a wheelchair with occupant in white on dark blue
background.
b) The sign shall >70 in.2 in area.
c) When in the path of travel, they shall be posted >80" from the bottom of the
sign to parking space finished grade.
Carlsbad O3-723
3/21/O3
CURB RAMPS
20. Curb ramps shall be constructed where a pedestrian way crosses a curb from the
parking lot to the sidewalk. Section 1127B.5.1.
21. Plans shall show that curb ramps are >48" wide with a slope of £1:12 (8.33%), per
Sections 1127B.5.2 and 1127B.5.3. The lower end of each curb ramp shall have a
1/2" lip beveled 45s, per Section 1127B.5.5.
22. Show that the landing at the top of the curb shall be level and >48" depth for the
entire width of the curb ramp. Section 1127B.5.4.
23. The slope of the fanned or flared sides of curb ramps shall not exceed 1:10, per
Section 1127B.5.4.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Chuck Mendenhall
at Esgil Corporation. Thank you.
Carlsbad 03-723
3/21/03
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 03-723
PREPARED BY: Chuck MendenhaU DATE: 3/21/03
BUILDING ADDRESS: 1838 Marron Rd.
BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VN
BUILDING
PORTION
Retail Tl
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA II Valuation
( Sq. Ft.) Multiplier
16610
cb
City Est
By Ordinance
Reg.
Mod.
VALUE ($)
498,300
498,300
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review:
Repetitive Fee
Repeats
Complete Review
D Other
r-i Hourly
D Structural Only
Hour
Esgll Plan Review Fee
Comments:
$1,775.48
$1,154.06
$994.27
Sheet 1 of 1
macvalue.doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CBQ3-'7$|3
ADDRESS /838 fY}c\rrcr\
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $10,000.00)
OTHER
IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
PLANNER
ENGINEER
DATE3-57-03
DATE
DDCS/Mlsfarms/Planning Engineering Approvals
Carlsbad Fire Department 030723
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review Requirements Category: Building Plan
Date of Report: Q7/3Q/2003 Reviewed by:
Fire Prevention
(760) 602-4660
Name:
Address:
Carol Burdon
5145 Golden Foothill Pkwy Suite 100
City, State: El Dorado Hills CA 95762
Plan Checker:
Job Name: Dollar Tree
Job #: 030723
Job Address: 1838 Marron Street
Bldg #: CB030723
Ste. or Bldg. No.
Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
D Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
D Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review
FD Job #
1 st 2nd 3rrt
030723 FD File #
Other Agency ID
Carlsbad- Fire Department 030723
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review Requirements Category: Building Plan
Date of Report: Q4/Q8/2003 Reviewed by:
Fire Prevention
(760) 602-4660
0. A,
Name:
Address:
Carol Burdon
5145 Golden Foothill Pkwy Suite 100
City, State: El Dorado Hills CA 95762
Plan Checker:
Job Name: Dollar Tree
Job #: 030723
Job Address: 1838 Marron Street
D
Bldg #: CB030723
Ste. or Bldg. No.
Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
Approved The item you have submitted for review has been approved subject to the
Subject to attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review 1 st
Ft) Job # 030723
2nd 3rd Other Agency ID
FD File #
Requirements Category: Building Plan
Requirement: Pending 05.32 Additional Requirements or Comments
Justify exiting through the stock room .
Page 1 04/08/03
WDY Structural • Civil Engineers
May 19, 2003
Rodriguez, Ripley, Maddux, Motley
129 West Virginia Beach Blvd
Norfolk, VA 23510
Attn: Cris Coriell
RE: DOLLAR TREE T.I. - MARRON ROAD, CARLSBAD, CALIFORNIA
ADA SITE CONDITIONS
Dear Mr. Coriell,
At your request WDY, Inc. has visited the above site to identify existing ADA site conditions and
prepare a plan of those conditions. Please refer to sheet C1.0 for a 1/8" -1 '-0" plan.
The proposed Dollar Tree tenant space is currently served by two ADA parking stalls and a curb
ramp approximately 100 feet south of the front door of the tenant space. The curb ramp
accesses the existing concrete sidewalk running across the front of the mall building. All cross
slopes and slopes in direction of travel along the curb ramp and sidewalk to the tenant space
front door conform to ADA standards.
If you have any questions regarding the above, please call our office.
Sincerely,
WDY, INC.
Cole G. Presthus, P.E.
Enclosure
6443 SW Beaverton-Hillsdale Hwy, suite 210 • Portland, OR 97221 • ph: 503.203.8111 • fx: 503.203.8122 • e: wdy@wdyi.com
CRR Architects 757 622 6883 09/22 '03 15:26 NO.064 01
EXIST CONSTRUCTION
ELASTflMgRlC SEALANT (EA SIDEJ.
6UUE-LAM BEAM WITH 6WB PER
1 CONSTRUCTION TYPE (EA
ENC
NOTEP
EXIST (1UE-LAM BEAM
EXIST!
PLATE1
! LIP-TRACK AND "TOP
MTL STUD SYSTEM
PROVII € «!0 TEC SCREWS 9 V OC ficA 5'DEJ TO
SECUR! EXIST SLIP-TRAC TO EXIST TOP PLATE"
MTL STUD - CONTRACTOR TO INSURE NO
SHALL OCCUR AT EXIST SUP-fRACK.
PARTIT
GP&
REPAIR
DETAIL
FINISH
ON WALL: EXIST WD STUD AND FiF SCOPE
E4CH SIDE TO STRUCTURE A3OVE. PATCH AND
TO MAINTAIN FIRE RATIN& PER Cx>DE. SEE
3/A4 FOR ADDITIONAL REQWREMI-NTS,
»ER FINISH SCHEDULE, SHEET A4,
JOINTS.
DESK&N
HEAP OF WALL DETAIL
PARTlTbN hALL: 6" (\& 6A> METAL STUDS 0 16"
OC WITH ONE LAYER 5/&" TYPE "X" <&WB E^CH
STRUCTURE ABOVE. FIRE TAPE ALL
CONSTRUCTION SHALL COMPLY WITH UL
FOR ONE HOUR F.RE RATING.
SCALE: I 1/2" = I'-O"
REVISION TO; DETAIL 1/A4 woa
A4
. CARLBBAO, OAUPOfMAOfQMNn^
REVISED WAU. SECTION
tfote 9/22/O^c [
project
drown
checked _ WJR
" 3N
sheet 1 of 1
a
E006/Z.0/T0
XVd
3WVN
3WI1
NOIlTOIdiy3A NOISSIWSNVdl
, SUITE 2100
, , CO 80202-5534
'AttrcMICHAEL D. ROSE 303 308 4500
ItTStl 1 -01234-ALL-O1102
THIS CERTIFICATE IS ISSUED AS A HATTER OF INFORMATION ONLY AND CONFERS
NO RIGHTS UPON THE CERTIFICATE HOLDER OTHER THAN THOSE PROVIDED IN THE
POLICY. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE
AFFORDED BY THE POLICIES DESCRIBED HEREIN.
COMPANIES AFFORDING COVERAGE
COMPANY
A ZURICH AMERICAN INSURANCE COMPANY
1 INSURED
RAS BUILDERS, INC. ATTN JANET HART
180 EAST HAMPDENAVE. #201 •
ENGLEWOOD CO 80110-, CT
COMPANY
B AMERICAN GUARANTEE AND LIABILITY INS. CO.
COMPANY
C AMERICAN ZURICH INSURANCE CO.
COMPANY
D
rttate^awi^**,*^^
THIS IS TO CERTIFY THAT POLICIES OF INSURANCE DESCRIBED HEREIN HAVE BEEN ISSUED TO THE INSURED NAMED HEREIN FOR THE POLICY PERIOD INDICATED.
LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
TYPE OF WSURANCE POLICY NUMBER POLICY EFFECTIVE
DATE (MM/DDrrY)
POLICY EXPIRATION
DATE(MM/DD/YY)LIMITS
GENERAL LIABILITY GENERAL AGGREGATE
COMMERCIAL GENERAL LIABILITY
I CLAIMS MADE |X j OCCUR
OWNER'S S CONTRACTOR'S PROT
GL033742S3-02 11/30/02 11/30/03 PRODUCTS - COMP/OP AGG
PERSONAL & ADV INJURY
EACH OCCURRENCE
FIRE DAMAGE (Any one Bre)
MEO EXP (Anyonaggscn)
$2,000,000
S2.000.000
1,000,000
1,000,000
300,000
10,000
AUTOHOBH£ LIABILITY
ANY AUTO
ALL OWNED AUTOS
SCHEDULED AUTOS
HWEDAUTCS
NOKOWNED AUTOS
BAP3374254-02 (AOS)
TAP3374255-02 (TX) .
COMBINED SINGLE LIMIT 1,000,000
11/30/02
11/30/02
11/30/03
11/30/03 BODILY INJURY
(Per pawn)
BODILY INJURY
(Poraccidsnl)
PROPERTY DAMAGE
GARAGE LIABILITY
ANY AUTO
AUTO ONLY-EA ACCIDENT
OTHER THAN AUTO ONLY:
EACH ACCIDENT
AGGREGATE
EXCESS LIABILITY EACH OCCURRENCE 10,000,000
UMBRELLA FORM
OTHER THAN UMBRELLA FORM
AUC377250002 11/30/02 11/30/03 AGGREGATE 10,000.000
WORKERS COMPENSATION AND
ettPLOYEIIS' LIABILITY
THE PROPRIETOR/
PARTNERS/EXECUTIVE
OFFICERS ARE:
INCL
EXCL
WC2976606-03 (AOS)
WC-3876086-02 (Wl)
11/30/02
11/30/02
11/30/03
11/30/03
EL EACH ACCIDENT 1,000,000
EL DISEASE-PODCY LIMIT 1,000.000
EL DISEASE-EACH EMPLOYEE 1,000,000
omsr
DESCWPTION OF OPERATONSSLOCATONS/VEHIClESrSPECIAL ITEMS
EVIDENCE OF INSURANCE COVERAGE AS RESPECTS ALL PROJECTS.
CITY OF LOS ANGELES
BUID1NG SAFETY
14425 ERWIN STREET
VAN NUYS, CA 91401
SHOULD AMY Of THE KXICKS OSSCRMED MHdN 1C atMCfUB} VBHSM. TW EJMMTKW BATS THBWOf.
me INSURER tfroaoma oovsuoe WHL ewoe*voR TO MM. 3B aura iwiiitM NOHCE TO mi
CERTIFICATE HOUKR WMHED HBRBN. BUT FMLUKE TO MM. SUCH NOTICE WMJ. «»Oae MO OtUOATOM OB
lUBUrY OF AWT KWO UPCW THE MSURER AFHMOM6 COvEIUGE. JTS AGDITS OR BfiPRESBMT»TIWSS. OR THE
MARSH USA INC.
BY: Dorothy A. Stevens
^J
c\ c O
°d^g^tt en
o
g
O
roO
§1
D ^
O H
o I
m _„ms00
•~ r\
P <m a§: om CDz >H O
; Mi Mi
> -f