Loading...
HomeMy WebLinkAbout1844 PALISADES DR; ; CB891825; PermitBUILDING PERMIT 01/17/90 09:55 Page 1 of 1 Job Address: 1844 PALISADES DR Str: Permit Type: RESIDENTAL ADDITION/ALTERATION Parcel No: 207-381-11-00 Valuation: 7,072 Construction Type: NEW Occupancy Group: M Class Code: Description: ADD SOLARIUM TO HOUSE 104 SF Permit No: CB891825 Project No: A8903231 Development No: Fl: Ste: 2678 01117/90 001 01 02 C-P11 135.0 347 Status: APPROVED Applied : 11/27/89 Apr/Issue : 01/17/90 Validated By: CD OWNER : TODD ROBERT & MARGARET 1844 PALISADES DRIVE CARLSBAD, CA 92008 CONTRACTOR : FRY CONSTRUCTION 5935 MIDDLETON ROAD SAN DIEGO, CA 92109 Lic. Lic. C 467984 619-729-1496 619 486 4416 *** Fees Required *** Fees Collected & Credits Fees: 199.00 Adjustments: .00 Total Credits: .00 Total Fees: 199.00 Total Payments: 64.00 Balance Due: 135.00 Fee description Units Fee/Unit Ext fee Data --------------------------------------------------------------------------- Building Permit 99.00 Plan Check 64.00 Strong Motion Fee 1.00 * BUILDING TOTAL 164.00 Enter "Y" for Electric Issue Fee > 5.00 Y Other > 10.00 10.00 REMODEL * ELECTRICAL TOTAL ($10 Minimum) 15.00 Enter 'V for Mechanical. Issue Fee> 15.00 Y Each Install/Reloc Appliance Vent > 1.00 4.50 4.50 * MECHANICAL TOTAL 20.00 CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 1. PERMIT TYPE I A - p COMMERCIAL DNEW OTENANI IMPROVEMENT B - [:]INDUSTRIAL DNEW DTENANT IMPROVEMENT C DRESIDENTIAL DAPARTMENT DCONDO DSINGLE FAMILY DWELLING DADDITION/ALTERATION Doupiex []DEMOLITION [-]RELOCATION DMOBILE HOME DELECTRICAL DPLUNBING DMECHANICAL DPOOL DSPA DRETAINING WALL DSOLAR IOTKER 4•/ .J__( - EST. VA PLAN CIt VALID. I DATE rDc'uy 64-00 soaress I 1W (fCf fL-WItd19 or 'Sul te No. Nearest Cross Streets 11rW,8...f7..4.c:.(C. ,.V . Subdivision Name/NLmer LEGAL DESCRIPTION Lot No , Unit Phase No CHECK BELON IF SUBMITTED: 02 Energy Calcs 2 Structural CaLcs 02 Soils Report Di Addressed Envelope ASSESSOR'S PARCEL '(_fl EXISTING USE PROPOSED USE BLDG. SO. FTC. 10 N OF STORIES wr.uMt.0 NAME L( P--cJQu ADDRESS ¶'t ?Cf CITY JRC...ACJ STATr ZIP CODE q2-O3 000 DAY TELEPHONE zos- SIGNATURE I '5' APPLICANT ' DCONTRACTOI - UGENT FOR CONTR9I DOWNER DAGENT FOR OWNER - NAME AD SS CITY 1&.(4's STATE ZIP CODE DAY TELEPHONE PROPERTY OWNER DLESSEE OTENANT NAME 9E&S \Z ADDRESS I Y c..ç q p'1-L is p4-P F,z ) 2iZ. CITY @lO42,.LSO STATE O, ZIP CODE DAY TELEPHONE teg I Ci 71f(/q CONTRACTOR tt-'o ,) NAME ,4. (i (J7m ADDRESS4 Z3 C9 f'j 4-7::I4_5 7 CITY 4,j -,4. 4bS/A4 ZIP CODE DAY TELEPHONE LICENSE CLASS CITY BUSINESS LIC. N 9' SIGNATURE (1 t, 2Lg4,O 4t4't DATE if - £7- VESIbNEK NAME CL1=-- (.Ar-tL1.-c2QcJ9 TRESS ,ojcq ,,- CITY 1.' A. c5C..Lç'% STATE)4— ZIP CODE C1 LC:) -72 DAY TELEPHON( R'(41 SATE LIC. ,, WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an acknitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY Pt'14{ 4 ij 3LICY NO. 01 cc — 3 01171 ION DATE '5 - - L -CIO Certificate of Exention: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so ato be99me dfject to the Workers' Compensation Laws qf California. SI DATE owner-au, taer uectaration: I neeoy attirm teat i am exempt tron tee Contractor's License Law tor tee following reason: I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Cede: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section ______________ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001). SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES DNa Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES ONO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES DNa IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code). LENDER'S NAME LENDER'S ADDRESS APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH NAY IN ANY VAT ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such rmit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any ti of er the work is commenced for a per (Section 303(d) Uniform Building Code). IC T-S C TUBE DOWNER to NTRACTOR 0 B PHONE APPROVED BY: File YELLOW: Applicant PINK: Finance CITY OF CARLSBAD INSPECTION REQUEST PERNIT# CB891825 FOR 07/18/90 INSPECTOR AREA PD DESCRIPTION: ADD SOLARIUM TO HOUSE 104 SF PLANCK# CB891825 0CC GRP M TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 1844 PALISADES DR STR: FL: STE: APPLICANT: CLIFT LAAPERRUQUE PHONE: 459 2059 CONTRACTOR: FRY CONSTRUCTION PHONE: 619 48 4,16 OWNER: TODD ROBERT & MARGARET PHONE: 619- 9 REMARKS: T1/MH/ROBERT/ INSPECTOR SPECIAL INSTRUCT: DRAINAGE SYSTEM AROUND SUNROOM TOTAL TIME: CD LVL DESCRIPTION ACT COMMENTS 22 PL Sewer/Water Service top *** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 022090 Rough Combo AP PD 020590 Frame/Steel/Bolting/Welding PA PD 012990 Ftg/Foundation/Piers AP PD ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619)560-1468 DATE: C3JoAe/ Is 1910 TURISD JURISDICTION: CAeL-mmy OPLAN. CHECKER DFILE COPY PLAN CHECK NO: SET: 7M cups ODESIGNER PROJECT ADDRESS: 44 Pos PROJECT NAME:___________________________________ n The plans transmitted herewith have been corrected where necessary and substantially comply with the .jurisdiction's building codes. . The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies D. identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Ej The check list transmitted herewith, is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. EJ The applicant's copy of the check list is enclosed for the .jurisdiction to return to the applicant'contact person. D The appiicant'scópy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. 0 Esgil staff did advise applicant been completed. Person contacts Date contacted: REMARKS: Lt the plan check has t Telephone # By: /c Enclosures: ESGIL - ! ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 5601468 DATE: DA.PLICAXi ROSDIT JURISDICTION: fl"PLAN CHE (]FILE COPY PLAN CHECK NO: SET: 1L DUPS / ODESIGNER PROJECT ADDRESS: 19,44, 1144SAPEVS PROJECT NAME: E The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. fl The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted ,herewith have significant deficiencies - identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith, is for your information. ffm The plans are being held at Esgil Corp. until corrected' plans are submitted for recheck. Loc.&) J The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of 'the check list has been 'sent to: tuPr L.APEUcLn _P.o1_5ex_L4_-M*_ El Esgil staff didnot advise the applicant contact person that plan check has been completed. Am Esgil staff did advise applicant that the plan check has VA been 'completed. Person contacted: C...LIFI Date contacted:- Telephone Telephone #_______________ REMARKS: Ruy19ji. (j,Je1Rc.' C1%Ok) Dai A i L.6 r-o SoRi uvi 14*' E. war BtJ o'i o. 5Ita&4J P4L PEM E3- Ii TI*L AM cotimec,moris., AePucic m C ftk wi C IT4 1Z' SOIL* fteorr By: Enclosures: ESGIL CORPORA'VION 0GA .DAA 0w 0 D ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619)560-1468 DATE: JURISDICTION: TY OF CARLSBAD SDICTI DFILE COPY PLANCHECK NO: - SET: CUPS .[—,DESIGNER PROJECT ADDRESS: PROJECT NAME: NAME:_________________________________ E The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. E The plans transmitted herewith will substantially comply Elwith the jurisdiction's building codes when minor deficien- cies identified are, resolved and checked by building department staff. IJ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to return -to the applicant contact person. The applicant's copy of the checklist has been sent to: ttt1 ?RiZirQo 'oL - LA bLLA 1ALiE&3IA e1 20 3 Esgil staff did not advise the applicant contact person that plan check has been completed. 0 Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone #________________ 0 REMARKS: By: _-4/, ESGIL C (I A 0 GA 13 AA 0 vw O DMIW Enclosures:_____________________ PLAN (BECK NO: JURISDICZION: CITY OF CA.SBAD PRQJX ADDRESS: 1&)4-4- ftt PLAN (X)RREC ION cr CITY OF CARLSBAD SThZ FAMILY AND DUPL11X WRLLThGS FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1985 UBC (elf. 7/31/87) 1985 UPC (elf. 3/30/87) 1987 NEC (elf. 10/28/87) 1985 UMC (elf. 8/28/87) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1985 Uniform Building Code, the approval of the plans does not permit the violation of any state, County or city law. To sneed um the recheck process, note on this list (or a copy) where each correction item has been addressed i.e., plan sheet, specification. etc. Be sure to enclose the marked un list when you submit the revised plans. TO: Li LkP.1mL) 4- 1,4 UJ tPru •t 'Lo,S Date plans received by jurisdiction: Date plans received by Esgil Corporation: ,I-7J--S9 Date initial plan check completed: By: C_ Applicant contact person: Telephone: *IIE: PAGE Nmanw ARE NOT IN SICE AS PAGES Haim NO rnm JING QjxiciONS WE DVf.R1'. List No. 63, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1985 UBC) PLANS ()Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite P208, San Diego, California 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. () Indicate on the Title Sheet-.-of the plans, the name of the legal owner and name of person ..responsible for the preparation of the plans- Section 302(a)7. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). S. Plans, specifications and calculationsshall be signad by the California state licensed eneinaer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). Aeavi gCZ 57Jcir1&9c.. OR A i.S0-1 OF 0 Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling,, garage, carport, patio, deck and balcony. Section 302(c). 7. Provide a statement on the Title Sheet of the plans that this project Shall comply with Title 24 and 1985 UBC. UMC and UPC and 1987 NEC. Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes. Show finish floor elevations and show elevations of adjacent finish grade. Show drainage patterns with minimum slopes. Section 302(c). -p,1-p q J Indicate distance from property lines, to proposed building. Section 302(c). Show on the title sheet all structures, pools, walls, etc. included under this application. Any portion of the project shown on the site plan that. is not included with the building permit application filed should be clearly identified as "not included." Clearly show if the lower level is a basement or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. 1. Exterior walls closer than 3 feet to property / lines shall be one-hour rated construction and have no openings. Such walls shall have 30 inch parapets when the building floor area exceeds 1,000 square feet on any floor. (Table 5-A, Section 1709 (a)). ,t3. Projections, including eaves, may not extend / more than 12 inches into the 3.foot setback from the property line. Section 1710. Eaves over required windows shall be not less I than 30 inches from the side and rear property lines. Section 504. 1,1 Plastic skylights shall not be installed / within 8' of an exterior wall located where openings in such exterior wall are prohibited or required to be protected. Section 5207 (a) 7. I . Projections, including eaves, shall be one- hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line. Section 1710. l/. Show location of permanently wired smoke / detector, centrally located in corridor or area giving access to sleeping rooms or above stair if sleeping rooms are on upper level. Section 1210. 8. A smoke detector shall be installed in the I basement of. dwelling units having a stairway which opens from the basement into the dwelling. Such detector shall be connected to a sounding device or other detector to provide an alarm which will be audible in the sleeping area. Section 1210. When the valuation of a room addition or f repair exceeds $1,000, or when sleeping rooms I are created, smoke detectors shall be provided at existing bedrooms per item 16 above. 5/10/89 .. . . 2 ROCK SIZES, LI, VETU.ATION AND GLAZThG 20. Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area. At least one room shall have not less than 120 square feet of floor area. Section 1207 (b). () Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (a. Appears to be deficient in 1rui M J5IE. OQbMrA kNO WINtCotJ -To Xr& O& kO - Scx Rom 22 Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required and mini um is 1.5 sq. ft. (Section 1205 (a)). At least 1/2 of the coon wall must be open and have an opening not less than 25 sq. ft. nor one tenth of the floor area of the interior room if light and ventilation is being supplied from an adjacent room. Section 1205 (a). 14. Required windows shall not open into a roofed porch unless the ceiling height is at least 7 feet, the longer side is at least 65% open, and the porch abuts a street, yard or court. Section 1205 (a). 2. Provide mechanical ventilation capable of I providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. Section 1205 (a). j6. No habitable room, other than a kitchen, shall I be less than 710" in any dimension. Section 1207 (c). 2/i. Show that ceiling height for habitable rooms is a minimum of 716". Section 1207 (a). 2. Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 710". Section 1207 (a). Dimension on the plans the 30" clear width for water closet compartments and 24" clearance in front of water closet. Section511 (a). Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to such doors and glazing adjacent to walking surfaces. Section 5406. 31. Glazing, in the same wall plane as a door, must be safety glazing if within 12" of the door and less than 60" above the walking surface, unless the glazing is leaded or faceted glass. Section 5406 (d) 6. Glazing in shower and tub enclosures shall be tempered, laminated or approved plastic (including windows within 5 feet of tub or shower floor). Section 5406 (d) 5. Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". Section 1204. W e. A mezzanine is an intermediate floor and may / not have a floor area exceeding 33 1/3 percent of the total floor area in the room below. The mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 42" in height. Section 1716. 3 . The loft you show does not comply as a / mezzanine floor and is, by Uniform Building Code definition, a story. Section 1716. / xrrs. sIAIRws. AND RAILINGS 6. Floors above the second -story shall have not less than 2 exits. Occupied roofs may have one exit if such occupied areas are less than 500 square feet and located no higher than immediately above the second story. Section ( 3303 (a). 37. Required exit doorways shall be not less than 1 36" in width and not less than 618" in height, and shall be capable of opening at least 90 degrees. Section 3304 (e). 3. Provide 36" high protective railing for porches, balconies, and open sides of stair landings. Openings between railing shall be less than 6". Section 1111. 3. Show how guardrail connection details are / adequate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B. 5/10/89 3 18. J9. 51f The maximum slope for a fire retardant built- ( up roof, with rock or gravel surfacing, is 3 inches in 12 inches. Section 3203 (e) 2. 58. The minimum slope for a fire retardant built- up roof, with cap sheet surfacing, is 1/2 inch in 12 inches. Section 3203 (e) 3. d9. Specify minimum 1/6 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a), Section 2305 (f) and Section 2511 (d) 6. 6I. Show roof drains and overflows. Section 3207. ii. Provide skylight details to show compliance I with Sections 3401 and 5207 or provide I.C.B.0. approval number. 6. Plastic skylights must be separated from each / other by at least 4 feet. Section 5207 (a) 6. Show attic ventilation. Minimum vent area is / 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). MASONRY 64. Provide fireplace construction details or note / construction to be per attached fireplace standard drawing. chapter 37. 5. Show height and construction detailsof all masonry walls. Chapter 24. Note that cleanout openings shall be provided at the bottom of all cells to be grout filled in accordance with Table 24-G. Cleanouts shall be sealed before grouting, after inspection. Show floor and roof connections to masonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310 & 2312 (j)3A. Provide details for damp proofing the foundation walls, below finish grade, where usable space exists on the interior side of the walls. Section 1707 (d). Show a minimum 2" air space and flashing I between planter and building walls. Section 2516 (c) 7. GARAGE AND CARPORTS l. Garage requires one-hour fire protection on / the garage side of walls and ceiling common to the dwelling. Table 5-B, Section 503 (d). 2. All elements supporting floor above garage, J including walls supporting floor joists, must 1 have one-hour fire-resistive protection on the garage side. Section 503 (b) 3. Show 1 3/8" solid core self-closing door for / openings between garage and dwelling. Section 503 (d). 714. Garages are not permitted to open into a room I used for sleeping purposes. Section 1104. /5. M occupancy separation is not required between carport and residence, provided the carport is open on two or more sides and has no enclosed uses above. Section 503 (a) Exception 3. 71. Show garage framing sections, size of header I over garage opening, lateral cross bracing at plate line, method bracing garage front and holddowns if required. Chapter 23. NOTE: Maximum shear panel ratio is 3 1/2 to 1 for height-to-width. Table 25-I. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 3304 (h). 78. Provide an 18" raised platform for any FAU, J water heater, or other device in the garage j which may generate a flame or spark. UMC I Section 508, UPC Section 1310 (a). .jIj,i ,7.'i to (.) S .Jp u () Per soils report, note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value. Section 2905 (c). 1ECb 8'I The foundation plan does not comply with the soils report recommendations for this project. Please review the report and modify design, notes and details as required to show compliance:___________________________________ Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, 71. comply with Section 3006 (d).1 and Section 2515 (a). Show ties and #9 wire in horizontal joints. 5/10/89 5 81 Provide notes on the foundation plan listing f the soils report recommendation for foundations, slab and building pad preparation. 82 Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). If The soils report recommendations excavations be reviewed by soils engineer. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: 1. The building pad was prepared in accordance with the soils report, 2. The utility trenches have been properly backfilled and compacted, and 3. The foundation excavations, formings and reinforcements comply with the soils report and approved plan." '4. Show height of all foundation walls. Chapter / 23. 5. Show height of retained earth on all foundation / walls. Chapter 23. 4. If cut or fill slopes exist, show distance of / foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. 8/. Note on plans that wood shall be 6" minimum f above finish grade. Section 2907 (a). Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Section 2905(f). For buildings adjacent to slopes steeper than 3:1, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device, a minimum of 12 inches plus 2 percent. 9,6. Dimension foundation per U.B.C. Table Floors Footin2. Supported* Steniwall Width Depth Thickness 1 6" 12" 12" 6" 2 8" 15" 18" 7" 3 10" 18" 24" 8" *Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. 94. Show foundation sills to be pressure treated, / or equal. Section 2516 (c) 3. 94. Show foundation bolt size and spacing. / Section 2907 (f). Specify size, I.C.B.0. number and manufacturer / of power driven pins. Show edge and end I distances and spacing. Section 302 (c). .. If required, show size, imbednient and location / of hold down anchors on foundation plan. Section 2312 (f), 302 (c). . If hold downs are required, note on plan that / hold down anchors must be tied in place prior to foundation inspection. Section 305 (e) 1. g4. Show adequate footings under all bearing walls / and shear walls. Section 2907 (b). 4. Show on the plans stepped footings for slopes / steeper than 1:10. Section 2907 (c). 9ê. Show minimum 18" clearance from grade to / bottom of floor joists and minimum 12" I clearance to bottom of girders. Section 2516 (c) 2. /9. Show pier size, spacing and depth into undisturbed soil. Table 29-A. l'. Show minimum underfloor access of 18" x 24". 7Section 2516 (c). )l. Show minimum underfloor ventilation equal to 1 / sq. ft. for each 150 sq. ft. of underfloor I area. Openings shall be as close to corners / as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c) 6. 142. Specify that posts embedded in concrete shall / be pressure treated per UBC Std. No. 25-12. I Section 2516 (c) 1. FRAMXNG 3. Show wall bracing. Every exterior wood stud / wall and main cross-stud partition shall be / braced at each end at least every 25 feet of length with 1 x 4 diagonal let-in braces or equivalent. Section 2517 (g) 3. 144. In 2-story buildings, shear panels at the / first story (at least 48 inches in width) shall be located at each end or as near thereto as possible and comprise at least 25 percent of the linear length of the wall, or provide design. Section 2517(g)3. 5/10/89 6 174. Specify on the building plans all of the / mandatory energy conservation requirements as I listed on the enclosure titled, "Mandatory Energy Conservation Requirements". 17k. Show the make, model and efficiency of the space heating (or cooling) system and provide heat loss calculations if the output exceeds 45,000 BTU/Hr. 176. For room additions, show that the glazing area of the addition does not -exceed 16% of the newly-conditioned floor area, plus glazing removed or relocated due to the addition. 4i 7. Provide fluorescent general lighting in kitchen(s) per CAC, Title 24, 2-5352(J). Please see additional corrections,, or remarks, ~78." on the following page. CARLSBAD S.F.D. & DUPLEXSUPPLXENT ]fr9. Energy conservation design should be for Zone 7 . See attached energy packages. ]80. Floor drains must have auto-prime (city I policy). Note exhaust fans cannot be ductless type (city f policy). New residential units must be pre-plumbed for future solar water heating. Note "two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No. 8093). Note "two 3/4" copper pipes must be installed to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 8093). It . All piping for present or future solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (city policy). Incorporate the waterproofing details, on-the I attached Policy 80-8, where interior living space occurs below grade at the masonry wall(s). Show on the Title Sheet on the plans, the f information required by the attached Developmental Services Sheet 112383. 187 All new residential buildings, including additions, require a soils report. Please submit two copies. l8. Heavy timber framing, minimum 6" x 10" beams / and minimum 8" x 8" post, for the structural beam and column supporting thef ire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). 19. UBC Adopting Ordinance 8792 requires Fire / Retardant roof on all structures (See. 18.04.230). Show compliance with UBC Section 3203(e). l0. City Ordinance 9792 requires two parking I spaces/unit with clear area of 201 x20' i.e. no washing machines, etc. Show compliance. ],1. Please see additional corrections, or remarks, f on the following page. The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208,, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact_________________ 6•4w,JR,w&-i. at Esgil Corporation. If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 1200 Elm Avenue, telephone 619/438-1161. Thank you. Enclosures: 5/11/89 10 CITY OF CARLSBAD Prepared bys Bldg. Dept. (4ieJ VALUATION AND PLAN CHECK FEE o Esgil PLAN CHECK NO._P/i-IZS BUILDING ADDRESS -- g'f fAL/PS P APPLICANT/CONTACT PHONE NO._________________ BUILDING OCCUPANCY -. 2-3 DESIGNER PHONE____________ TYPE OF CONSTRUCTION /-J CONTRACTOR PHONE___________ BUILDING PORTION BUILDING AREA VALUATION MULTIPLIER VALUE • ______ __________• _____ 1 Air Conditioninz Commercial Residential Res. or Comm. Fire Srinklers _______________ ___________ Total Value Building Permit Fee $ • • S • /3 00 Plan Check Fee $ • $ 9_7 COMMENTS: • Plans received by Esgil after July 31, 1987 shall have permit and plan check fees calculated per 1985 UBC. • / 'SHEET / OF / 12/87 'I 1 S T BUILDING PLANCHECK ENGINEERING CHECKLIST DATE: /2-2II ITEM COMPLETE PLANCHECK NO. ITEM INCOMPLETE - NEEDS YOUR ACTION 2 3 181'_162 N R XITEM SELECTED D D / I C C C H H H E E E C C C K K K 0 El El PROJECT ID: /3DL'Ai2)770,O LEGALREQUIREMENTS SitePlan Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width and dimensioned setbacks. Show on site plan: Finish floor elevations, pad elevations, elevations of finish gra_.e_jacent_to_building, existing topographical lines existing _and proposed siq, driveway with percent (%) grade andinage_pa. Provide legal description and Assessors Parcel Number. Discretionary Approval Compli ance 4. No Discretionary approvals were required. Project complies with all Engineering Conditions of Approval for Project No._______________________ Project does not comply with the following Engineering Conditions of Approval for Project No.______________________ Conditions complied with by: _Date:__________ FieldReview Field review completed. No issues raised. Field Review completed. The following issues or discrepancies with the site plan were found: Site -lacks adequate public improvements. Existing drainage improvements not shown or in conflict with site plan. Site is served by overhead power lines. Grading is required to access site, create pad or provide for ultimate street improvement. FRM001O.DH 08/29/89 Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. Other:_______________________________________________ Dedication Requirements No dedication required. - Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8½" x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as follows: Dedication completed, Date: By: Improvement Reaui rements No public improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be reoaired to the satisfaction of the City inspector prior to occupancy. Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit. for separate plancheck process through the Engineering Department. Improvement, plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are:__________________________________________ Improvement plans signed, Date: By: FRM001O.DH 08/29/89 13. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent title report on the property, and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date________________ By:______________ Grading Requirements ______13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). No grading required as determined by the information provided on the site plan. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. Grading Inspector sign off. Date: By:_________ Miscellaneous Permits Right-of-Way Permit not required. Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the following: cX118. Sewer Permit is not required. Sewer Permit is required. A Sewer Permit is required concurrent with Building Permit issuance. The fee required is noted below in the fees section. Industrial Waste Permit is not required. FRM001O.DH 08/29/89 V . 21. Industrial Waste Permit is required. Applicant must complete Industrial Waste Permit Applicantion Form and submit for City approval prior to issuance of Building Permits. Permits must be issued prior to occupancy. Industrial Waste Permit accepted - Date: By:________________ Fees Required Park-in-Lieu Fee Quadrant: Fee per Unit: Total Fee:_______ Traffic Impact Fee Fee Per Unit: '- Total Fee: A/14-24. Bridge and Thoroughfare Fee Fee per Unit: Total Fee: ________ Public Facilities Fee required. Sewer Fees Permit No. EDU's______________ Fee: ' Sewer Laterquired: -04 Fee:.7LQ REMARKS:(5bh 6LP/ Om R221T7 £J) . tY5T1XJ-F'€OM OD,rY) Zt - - - - - k. ENGINEERING AUTHORIZATION TO ISSUE PERMIT Date:______________ FRMOO1O.DH . 08/29/89 Facilities Management Fee Zone: _____ Fee: I PLANNING CHECKLIST 0 - - cc 10 0 0 Plan Check No. — l S Address A P N : Planner Phone 438-1161 Type of Project andUse S//Wkyl Zone L2c." Facilities Management Zone Legend Item Complete Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number that deficiency was identified IIIU ZEnvironmental Review Required: YES NO TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required: YES NO " TYPE APPROVAL/RESO. NO. DATE: PROJECT NO. OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Ile& C1 Coastal: YES NO DATE OF APPROVAL: Compliance with conditions of approval? require action. Conditions of Approval If not, state conditions which EIYf 0 Landscape Plan Required: YES •______ NO XT - See attached Submittal requirements for landscape plans Site Plan: El 0 C3 • I. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. 00 0 Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. oo 0 Provide legal description of property. Provide assessor's parcel number. Zoning: 00 0 Setbacks: Front: Required Shown mt. Side: Required Shown - Street Side: Required Shown Rear: Required Shown 00 0 Lot coverage: Required Shown 00 0 Height:,. Required Shown 00 0 Parking: Spaces Required Shown Guest Spaces Required Shown Additional comments and remarks have been made on the building plans. These marked-up plans may be picked up at the Building Department. These marked- up plans must be resubmitted with the revised plans for this prect. Have plans been marked up? YES NO @1 0 Additional Comments Ofl!O4iW Jk?,ak,, Qffi,fJ/ OK TO ISSUE DATE PLNCK. FRM PROJECT: Slate of California, George Deukinejian, Governor. California Coastal Commission 1333 Camino Del Rio-S., Suite 125 'San Diego, Ca92108 (619) 297-9740 DATE: AV PA UA41 -- , 7 . . ... . .. . NAME:I'M -Tr I V Li M 'sA-e -s• t . . . .. #-I' .-....... LOCATION: . ... .. .. . . .This is to certify that this location and/or proposed project has been reviewed by the staff onthe San Diego Coast District -Commission. A coastal development permit-is not necessary because of the item(s) checked below.. Appropriate local permits may now be obtained. . . ... . . .... .., . .. . . The site is not located within the coastal permit area as adopted in the California Coastal Act of 1976 and effective January 1, 1977, and modified effective.January 1, 1980.. . The proposed development is included in Catagorical Exclusion-No. adopted by the California.Coastal Commission. The proposed development is judged to be repair or maintenance activity not resulting in an addition to or enlargement or expansion of the object of such ctivities (Section 30610(d) of Coastal Act). T proposed development is an improvement to an existing single family residence (Section 30610(c) of the Coastal Act) and not located in the area between the sea and first coastal road or 300 feet (whichever is greater) (Section 13250(b) (4) of Administrative Regulations). The proposed development is an improvement to an existing single family residence and is located in the area between the sea and the first coastal road or 300 feet (whichever is greater) but is not a) an increase of 10% or more of internal floor area, b) the construction of an additional story, or c) a significant non-attached structure (Sections 30610(a) of Coastal Act and Section 13250(b) (4) of Administrative Regulations). The proposed development is an interior modification to an existing use with no change iir the density or intensity of use (Section 30106 of Coastal Act). The proposed development is an improvement to a structure other than a single family residence or public works facility and is not included inexctüded catagories of development - (Section 13253 of Administrative Regulations). The propöed development is the rebuilding of a structure, other than a public works facility, destroyed by natural disaster. The replacement conforms to all of the requirements of Coastal Act Section 30610(g). The proposed development is exempt under Section of the Commission's "Interpretive Guideline on Exclusions from Permit Requirements." Other: This• certification is based on information provided by the; recipient of this letter. If, at a later date, this information is found to be incorrect, this letter will become invalid, and any development occuring must cease until a coastal development permit is obtained. Very truly yours, C". Charles Damm - District Director PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 1. PERMIT TYPE I A - p COMMERCIAL ONEW DTENAUT IMPROVEMENT EST. VAL 1fL"l.J PLAN CE DEPOSIT___________________________ w VALID. BY DATE B 0 INDUSTRIAL ONEW OTENANT IMPROVEMENT C DRESIDENTIAL DAPARTMENT DCONDO DSINGLE FAMILY DWELLING DADDITION/ALTERATION DDUPLEX DOEMOLITION DRELOCATION DHOOILE HOME DELECTRICAL DPLUMBING DMECHANICAL DPOOL DSPA DRETAINING WALL DSOLAR D OTHER ,_,. 4e Building or suite NO. Address 4.' (( j7 9 C- J I2—OE.,S 7 1Z Nearest Cross Streets 5 On D2 Energy Calcs 02 Structural Cates 02 Soils Report Dl Addressed Envelope ASSESSOR'S PARCEL EXISTING USE PROPOSED USE DESCRIPTION OF WORK 12's- cf C S (Of) To - Qo BLDG. 50. FIG. A OF STORIES CONTACT PERSON NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE SIGNATURE APPLICANT DCONTRACTOR ENT FOR CONTRACTOR DOWNER DAGENT FOR OWNER NAME (k LL ADDRESS c2,ôs( a Cf CITY L .- (3 L.L... STATE C 4" ZIP CODE DAY TELEPHONE f5-4 1. ( S OLESSEE DTENANT PROPERTY NAME c'r ADDRESS I?((cC P*go CITY C4..-R..L. S t340 I" STATE. ZIP CODE DAY TELEPHONE CONTRACTOR NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE STATE LIC. A LICENSE CLASS CITY BUSINESS LIC. A SIGNATURE TITLE DATE DESIGNER NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE STATE LIC. A WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. Q. INSURANCE COMPANY POLICY NO. EXPIRATION DATE Certificate of Exception: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE OWNER-BUILDER DECLARATION Owner- Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Cede: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Cede: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) Licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Cede: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Cede) or that he is exempt therefrom, and the basis for the alleged exception. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001). SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES ONO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES ONO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' DYES DNa IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS PET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction Lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code). LENDER'S NAME LENDER'S ADDRESS APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JIR)ONENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time af r the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). 1 OWNER [:]CONTRACTOR PHONE PROVED BY: WHItE File YELLOW: Applicant PINK: Finance ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619)560-1468 DATE: 4, If'ii MJfKi9 14 I" DL1-- RISDICTI JURISDICTION: JWL.4 FILE COPY SET: PLAN CHECK NO: D PROJECT ADDRESS: 8DESIGNER PROJECT NAME: 0—ne!e Th plans transmitted herewith have been corrected where ssaryy and substantially comply with the jurisdiction's building codes. . U The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. .Cj. The plans transmitted herewith have significant deficiencies identified on the .enclosed- check list and should be corrected - and resubmitted for a complete recheck. U The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. J The applicant's copy of the check list is enclosed for the jurisdiction to. return to the applicantcontact person. The applicant's copy of the check list has. been sent to: Esgil staff didnot advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has beerôompleted. Person contacted:_____________________ Date contacted: . Telephone #________________ U REMARKS: /J( n -. . By: Enclosures: ESGIL CORPORATION(/ EGA .DAA El VW C) DM