HomeMy WebLinkAbout1845 McCauley Ln; ; 86-566; Permit"' z 0 ;: .. a: .. J (J
i!:
"' il
(J
a: ..
Q
J 5 ~ .. z ~ 0
z 0 ;:
l z ..
0. ,.
0 (J
"' ir ..
" a: ~
![
O I hereby ■!firm that I am licensed under
provisions ol Chapter 9 (commencing with
Section 7000) of Division 3 ot the Business
and Prolanlons Code, and my license 1s in
full force and effect
I hereby a1tirrn lhal I am exempt from the Conlrac
to, s License Law lor lhe following reason 1sec 7031 5
Busmess and Pro1ess,ons CIXle Any c,ty or county wh,u ·e
qu,,es a permit to construct airer ,mprove demo11sh or 1
repair any strucTu,e prior to ,ts ,ssuance also requires !heap
pircanl lor such pe,m,1 10 t,le a s,qnelJ statement that he is
1,censM pursuant lo The prov,smns of The t..ontraoor,
Lrc?nse Law IChap1er 9 commenc,ng with Sec:1,on 7000 ol
Q,v,s,on 3 of The Business and Protess,ons CMe; or that ,sex e,npt therefrom and the basis for the alleged exempT,on Any
,iola1,nn ol Section 7031 5 by an appl,cant 1or a perm,t wo 1ects lhe applicant loa c,v,I pena;ty of nol mo,e lhan live l1un
dred dollars 1$5001
I as owoe, ol the p,operly, or my employees with wages
as their sole compensahon will do lhe wo,k anct the struc
ture ,snot ,nrended or otfered 1or sale 1sec 7044 Business and Proless,on~ Code The Contraclor s License Law does
not apply lo an owner of properly who builds or 1moroves thereon and who does such work himself or lhrough h,s own emoloyees provided that such ,mprovemenls are not intend
ed or o!lered lor sale 11. however. lhe bu1ld1ng or 1mprove-menl 1s sold within one year of complehon_ the owner-builder
w,11 have the burden of proving that he did not bu1ld or 1m prove tor !he purpose o1 sale1
I. as owner of the property. am exclus,vely contracr,ng w,th hcensed contractors lo con~truct the pro1en (Ser 7044
Business and Professions Code The Contractor s L,cense Law does not apply 10 an owner o1 property who bu,lds or ,m proves thereon and who con1rac\s for each pro1ects w1lh a
contractor(sl license pursuanl 10 the Contractors Llcen~e Law)
As a homeowner I am 1mprov1ng my home and the follow ,ng cond1t1ons ex,st
1 The work 1s being perlormed prior to sale
2 I have lived m my home lo, twelve months pno, 10 completion of lh,s work
I have no1 claimed lh,s exempT,on durmg the last three years
L ' I am exempt under Sec -----~ 8 & PC 1or 1h,s reason ____________ _
I hereby a11irm thal I have a certificate al consent to
sell insure or a cert1t1cate of Workers Compensation In
su,ance or a cert1•1e,j copy thereol 1Sec 3800 Labor Code!
POLICY NO
COMPANY
Copy IS hied with the c,ty
Cert1f1ed copy 1s he,eby furnished
CERTIFICATE OF EXEMPTION FROM WORKERS COMPENSATION INSURANCE
1Thts sectmn need not be completed 1f the perm,·
1s for one hundred dollars ($1001 or less!
_ I certdy that •n the performance of the work for which lh1s permit ,s ,ssued. I shall not employ any person ,n any
manner so as to become sub1ect to 1he Wor~e,s Com pen
sa11on Laws al Cal1forn1a
NOTICE TO APPLICANT If. after mak,ng this Cert,hcate
of Exemption. you should become sub1ect 1o the Workers
Compensation prov,s,ons ol the Labor Code you must
forthw,th comply with such prov,s,ons or th,s permit shall
tie deemed revoked
I hereby aff,rm that there 1s a construct,on lending
agency for the performance of the war~ lor which tn1s per
m,t ,s ,ssued 1sec 3097 C1v11 Code1
Lenders Name
Le•1der s Acdress
USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS
CARLSBAD BUILDING DEPARTMENT APPLICATION & PERMIT 2075 Las Palmas Dr., Carlsbad, CA 92009-1915 (619) 438-1161
JOB ADDRESS AV. ST. RO. THOMAS BROS NO. I ;i ~, ";~A;ON BUSINESS LICENSE # VALUATION PERMIT NUMBER
~ LI ,; mcr,,,.1P, l nn10 I '8 j 2~.'7 '2?0 -5G~
COT BLOCK J _su801v1s10N ,, ASSE;~ PARCEL NO c) CONTRACTOR • I CONTRACTORS PHONE # ZONE
2----IYlS72 -,, ;i.;,o ~'i 0
OWNER'S NAME ; 17 '> ;,";;;~N• -~@he..,+~ h, Wf IJc;Z)n CONTRACTOR'S ADO RESS STATE LICENSE NO. BUILDING SQ FOOTAGE
I/ c;,., . A""'> :2.. 560 OWNER'S MA!UNG ADDRESS
IJ:~.lv,,J:;:"; " ,,. -' -1\.,-#1q 11.~ l"I+-q..:;wg:. DESIGNER DE SIGNE R'S PJiONE
_.:-~ ~ Y" vYI f\ \,er -··t2.:3 5 !.J5 / 0,ESt;;RIPTl.0!'1 Of 11¥9FIW<k; . -:--·-· , ' ... .. ----. -. . . . -DESIGNER'S AOORl:SS ,. TUI ·-STATE UCENSE·NO,
---. ·-. ::, {" :-'.._4l .. c:;·· --1-Aft',..I. r.:.. -\IL\ 5. ffiti,~ ... ., C,D/03&3 rnrt , •, IC/: ,-,C, I'"\.· u r ·-J-;~,: -" FLA ELEV NO OCC GP EDU 0004 09/01 0101 02BldPmt 9556-t -'
,, STORIES R. ~ I . . . . ' vO "'CJ 2. I CENSUS TRACT I '1'2s•n RES~NITS I GRADING PERMIT ISSUED l REDEVELOPMEr--.T TYPE OCC LOAD FIRE SPR
AREA .'?\I' CGN •□ ,;£ I I •□ ' D -□' Nor Vil/id Un/en M~chme Certified .
QTY PLUMBING PERMIT -ISSUE 7 Dl-QTY MECHANICAL PERMIT -ISSUE ;s.-~ SUMMARY/ACCOUNT NUMBER
I• EACH FIXTURE TRAP -i • ._, I INSTALi FURN □UCTSUPT0100000BTU '-f -"'' BUILu""' rc:nml 1 UU 1-lj 1 U-UU-U0-8L20 r ... ·~1:..--..n1
EACH BUILOING SEWER l Sr OVER 100.000 BTU SIGN PERMIT 001 -810-00-00-8221
EACH WATER HEATER AND OR VENT ~ 5( BOILER:COMPRESSOR UP TO 3 HP PLAN CHECK 001·810-00-00-8891 w I "i" .On
EACH GAS SYSTEM I l U 4 OUTLETS -'" 801LER.:COMPRESSOR 3 15 HP TOTAL PLUMBING 00 ;-810-00-00-8222 ,::,~. "'"
EACH GAS SYSH.M 5 0 R MORE I M!:.1 A.L F18EPLACE r,; ,c'/ ELECTRICAL 00' -81 0-00-00-8223 "'" ,"0
EACH INSTAL ALTER, REPAIR .\'ATER PIPE -:. VENT FAN SINGLE DUCT ..,, . .::, MECHANICAL 001-8 '0 -00-00-8224 U4,00
EACH VACUUM BREAKER MECH EXHAUST HODO UUCTS MOBILEHOME 001-8 10-00-00-8225
WATER SOFTNER RELOCATION OF EA FURNACE-HEATER SOLAR 001-810·00-00-8226
FAC'1 RQ(Jf nRi1l~J , ;fJ'.)1flt ·1 DRYER VENT STRONG MOTION 880-519-92-33 i -~ • (os.J
TOT kl MECHANICAL ~ CCRINi<LERS 00 1-810-00-00·82 27
TOTA! Pi IJMBINL I 5G, .-;{ L/L/ 00 r .... r,,..' mrr FEE-_.,-•-20-810-00-00-874r .t I z, ~ ~ -, . ~-
BRIDGE FEE -360-810-00-00-8740 r.,i. 1-"'i'f#. 7" '
QTY ELECTRICAL PffiMIT -ISSUE _ _. oo QTY. MOBILE HOME SETUP ~'-"' 0 -=---PARK·IN·LIEU (AREA ..) I
/ NEW CONST EA AMP SWl IJKR 'J.on Si.'.) IV CAR PORT TIF 312-81 0-00-00-8835 t ... rv,,rv-1
I PH l PH AWNING LA COSTA TIF 3 ·11-810-00-00·8835
EXIST !:iLOG EA AMP swr BKR GARAGE FMF
I PH J PH . LICENSE TAX 001-810-00-00-8' 62
REMODEL AL ltR PER CIRCUII ,,, r., A_.,.. "' -I ,.. , c;<ui 880-519-92-57 ' ... '-In, or
TE"iiPPOlE lllll AMPS ~' ~ ........... _..1..~ ~ ,
OVER 2UU AMPS
If.MP OCCUPANCY 130 DAYSI . 1 "FR1illl 11
.
City of CA18.rr
CREDIT DEPOSIT <: -Jr, ... -jl
TnfAl EiHlHILAl I 55 Of
TD~ A·. ~!:~L FEES PAYABLE I ,-,C, 4,.s; I ._. I.~ ------
. . Expiration. Every per_'!'it inu,Q bytt:ieBuil<fmg Qff,c1eJ under theprm1s1ons oftb1s. -· I HAVE CAR:t:FfUl,LY EXAMINED THE COMPLETED .. APPUCATlON AND PERM1r· AND DO HEREBY * AN-OSHA·PEAMIT IS AE0UIREDFOR EXCAYATIONSOYEA
CERTIFY, ~O~R. PE_NA,tTY QF .. P'E:RJ\)RY THAT All INFORMAlJON HEREON INCLUDING THE Code shall expire by hm1tat1on and become null and 'I01d JI the budding o, work 5' O" DEEP ANO OE.MOI..ITION OR CONSTRUCTION Of avthonzed by such petmit is nol commenced within 180 days lrom the ctate of such DECLARAftONS ARE' TRUE ANp CORf!ECT AND I FURTHER CERTIFY AND AGREE !FA PERMIT I~ permit, or d the bu11d1J or w:,ork al/1h0fize<f by such perm1l 1s suspended or STAUCT\JRES OY£R 3 STORIES IN HEIGHT
ISSUED: TO COMPLY WITH Alt: CITY: COUNTY ANO STATE LAWS GOVERNING BUILDING CON-abandoned at am.-lime• ter the woril 1s commenced for II ;:.;.nod of 180 cta··s
STRUCTION. WHETHER SPECIFIED HEREIN OR NCH I ALSO AGREE TO SAVE INDEMNIFY AND APPLIC~N•;:z-. LP O~~ CONTRACTOR 0 APPROV J: ~ 1°1lt!r1 KEEP HAflMLESS·THE CITY OF CARLSBAD AGAINST ALL UABILITIES. JUDGMENTS. COSTS AND (\ .oQ EXPENSES WHtGH 'MAY IN ANV·WAY ACCAUE AGAINST SAID CITY IN CONSEQUENCE OF THE -y PHONE [] GRANTING OF TtttS f>ERMH. ~ er -,1 -\ f, '
~
U:
>-~
0 0.
E w f--
"C
0
CJ
C m u
0. 0. <t
I
~
C a:
0 w w w w w <t
~ 0
o3 >-
w u C m
C
u.
C w ~ CJ
0 u w 0. w
C
w
"' ;;
' TYPE I DATE INSPECTOR ~" --,5(,;,fo
BUILDING I
FOUNDATION ' I A • ~ ,.,_ II/, ' FIELD INSPECTION RECORD
REINFORCED STEEL ' fto·,, r it ..
MASONRY I
REQUIRED SPECIAL INSPECTIONS :,r;-,: r, ~:: ! -• _ _-Jp,tSR,~CTCR'S NOTES .
GUNITE OR GROUT ' I
REQ IF INSPECTORS DATE ' ... ~?, . .-\'.+-~ :· ,:: :,,.· INSPECTION CHECKED APPROVAL
SUB FRAME □ FLOOR □ CEll!.ING . /I
SHEATHING □ ROOF □ SHEAR 1//. • I) I r/~~ ~
FRAME 7 "· ·n r/l ,_-1 £.,. I
EXTERIOR LATH I u,.,~:~ ·p ~\
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP
-,-' _,,
·-STRUCTURAL CONCRETE . ' 'i l .,, . OVER 2000 PSI
INSULATION I " ·,"•lj //t 1 'L
INTERIOR LATH & DRYWALL ' . PRES TRESSED
CONCRETE
POST TENSIONED
' CONCRETE
PLUMBING --,-,_
I FIELD WELDING
W SEWER AND BL/CO /PL/CO "I. '--", """" UNDERGROUND □ WASTE □'WATER ,
A
--~ HIGH STRENGTH
BOL Ts
TOP OUT □ WASTE □ WATER If ,ff,. ·IO //t._7 l, SPECIAL MASONRY
TUB AND SHOWER PAN ! ,, .
GAS TEST I fl.fl ,r, f'',_7 'L Pll ES CAISSOM'
□ WATER HEATER □ SOLAR WATER
I
-ELECTRICAL I I} .
□ ELECTRIC UNDERGROUND Y1' UFFER 'f,J'i·' f'\, 'I"
ROUGH ELECTRIC I • /L ·r. //4-Z '\ '
D ELECTRIC SERVICE □ TEMP<DRARY • □ BONDING □ POOL -'
-I-----~
I
-
MECHANICAL I
□ DUCT & PLEM., □ REF. PIP(NG ·-A .
HEAT -AIR COND. SYSTEMS I ,I -0 l -'},tJI\ -~ ~-
-
VENTILATING SYSTEMS ' I(.\._ , I,
I \' I
CALL FOR FINAL INSPEC7'ION WHEN ALL APPROPRIATE
-----.... ............. ---·
FINAL I
PLUMBING I
I ~~
ELECTRICAL I ~ .. -
MECHANICAL .
I • I _1
GAS ;
'\,._ 11.-v .. -BUILDING I _I • \\\:
SPECIAL CONDITIONS '
' I " -...
'
CASHIER'S VALIDATION
Qrttv of Clrarlsbab
SEWER PERMIT APPLICATION
APPLICANT TO FILL IN SHADED AREA
BUILDING PLAN CHECK NUMBER: PC -?
BUILDING ADDRESS:
NUMBER OF EDU'S: ___ /_') __________ _
V I rA
CONTRACTOR: ___________ __,_1 ___ ~1----------------------
0004 /0 l\
CONNECTION FEE
~
COST PER UNIT _____ x NO. UNITS
LATERALCHARGE: _____________ _
ASSESSORS PARCEL NUMBER: ___________ PREPARED BY: ✓ 1 J,.,,
I /
Ii
(PAINTED NAME)
_,r JI ... V ~ Jy ~ , ,, > < J. I\J . , ..
J , , lu , , / J
WHITE: DPS GREEN: Finance CANARY: Water PINK: Building GOLD: Applicant
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: 86-566 DATE: 2-3-88
PROJECT NAME: -------------------------------
ADDRESS: 1845 mcCaulev In
PROJECT NO.: ________ UNIT NUMBER: _______ PHASE NO.: ______ _
TYPE OF UNIT: sfd NUMBER OF UNITS:
CONTACT PERSON: __ r_o_b_--'-o_n_n_l'-d_r._o_n ______________________ _
CONTACT TELEPHONE: __ ---'-7 ~58"----2-'7-'7_R _______________________ _
DATE FEB. 1 0 1988 INSPECTED: APPROVED ✓.ISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
Costa Real Municipar Water District
COMMENTS: liRgineering Department · -· -
(S 19) 4il8·3367
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: 86-566 DATE: 2-3-88
PROJECT NAME: ----------------------------------
ADDRESS: --~*~--'~8_4'"""'5~m_c_C_a..:::u_;;_le"--v......_l;_;_n_;__ ____________________ _
PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.: _______ _
TYPE OF UNIT: sfd NUMBER OF UNITS:
CONTACT PERSON: rob donaldson
CONTACT TELEPHONE: __ ~7~5~0;_;_-~2~7~7~0 _______________________ _
11 r "'t
INSPEC]sD ,I ~?
BY: C..... 2--~~141',.,,,.. ~f
DATE ~FJ INSPECTED:.;z ~ APPROVED ~ DISAPPROVED
INSPECTED DATE BY: __________ _ INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE BY: __________ _ INSPECTED: APPROVED DISAPPROVED
COMMENTS: -----------------------------------=--
Rev. 1/86 WHITE: Suspense BLUE: Water Dlstrl ANARY: Utilit ies PINK: Planning GOLD: Fire
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: 86-566 DATE: 2-3-88
PROJECT NAME:
j
ADDRESS: % 1845 mcCaulev In
PROJECT NO.: UNIT NUMBER: PHASE NO.:
TYPE OF UNIT: fd NUMBER OF UNITS:
CONTACT PERSON: rob donald on
CONTACT TELEPHONE: 75 -2778
ull "'\
INSPECTED DATE d--9~PPROVED v----BY: INSPECTED: DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
COMMENTS:----------------------------------
Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineerin CANARY: Utilities INK: Planning GOLD: Fire
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: -566 DATE:
PROJECT NAME: ----------------------------------
ADDRESS: 1845
PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.:
TYPE OF UNIT: ___ s_t _f _________ NUMBER OF UNITS:
CONTACT TELEPHONE: ___ 7_5_-_2_7_7_8 _______________________ _
~rcTEDI{~
INSPECTED BY: __________ _
INSPECTED BY: __________ _
~N•;:ECTED,,.d~ APPROVED
DATE INSPECTED: _____ APPROVED
DATE
INSPECTED: _____ APPROVED
--~-DISAPPROVED __ _
DISAPPROVED __ _
DISAPPROVED __ _
COMMENTS: -----------------------------------
Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utilities LO: Fire
ESGIL CORPORATION
9320 CHESAPEAKE DR •• SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: QAPPLICANT
JURISDICTION: 0, l,sb.,,d
8 ,rnB I$QICTim,t::::, D PLAN CHECKER
QFILE COPY
QUPS PLAN CHECK NO: '¥le -~(,,(,, (1£\ D DESIGNER
PROJECT ADDRESS: t:1c. C,:;,, '•t J..,,
PROJECT NAME: :Sr-:12.
□
•
□
□
□
□
•
□
•
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified 6,10.....:i are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted: _______ Telephone ii ________ _
REMARKS: Appl1(4.,1S6g11lc/ ~11k,..,:n:: i\;;o Ca:PJ•\ ·=tj,,::tt,13$
Cs ( < ·~ • :r;, :n:;.. bl 46. d, pr; 1q..-Q Pf>,ov"-.R Pr10T F
By: ";;,Ai)Cr.
ESGIL CORPORATION
11-1~-Y(,p
Enclosures:_~N'-=-'e~,-,'-'--"e~-------
•
ESGIL CORPORATION
9320 CHESAPEAKE DR .• SUITE 208
SAN DIEGO, CA 92123
(619) 560· 1468
DATE: □APPLICANT Bi~~!sg~~~~~::::, JURISDICTION: Co, l.s 6c,d -----~------------
PLAN CHECK NO: 1Jl, -5 (e Ce l t 1 BFILE COPY
UPS
□DESIGNER
PROJECT ADDRESS: tv\'-Cavl, 'J L..,.
PROJECT NAME: ~,= R . ---'--''---'--'---------------
□
D
D
•
D
•
□
□
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes. ·
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified-:----:--------,------,---,----=-=-----are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information •
. The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck. 1• ··
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's
f-1.-.-,ry' Mill.-,-I
copy of the check list has been sent to:
///If :S. t-,1,,,,. • F~ I/ b,-,1,:. • Ca . 4..10.J.)
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted: ~}~~~,~~'T/~~~t~~~•r~-------
Date contacted: -~J_0=----"'5'...,___ Te 1 ephone # ...2-J ~ -~ q 5 I
REMARKS: __________________________ _
By: 'SA-DI:'.<;
ESGIL CORPORATION
/o-.;>'1-'ill,
Enclosures: No,, -~~~--------
JURISDICTION: Ca~ Is 6--. ,j.. DATE I/-.;• °i(,
Enclosures•~A/=O~n~~~-----";---
PROJECT ADDRESS: ye e,,,,,,,,, In.
l-lrn, y y,/1,,,,. I TO: 11/4 .s_ Ma,a { J ,=.,11 br""k.. . ?---"'-'oas>
Date plans received by ·jurisdiction /,,,,l.3 -f€,,
Date plans received by plan checker l<1-.>'f
Date initial plan check completed//...,;-,..,, by.S.4..1),2,$;
FORWARD: PLEASE READ
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for
the handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections
.based on l~ws and ordinances enforced by the
Planning Department, Engineering Department
or other departments.
·The items circled below need clarification,
modification or change. All circled items have
to be satisfied before the plans will be in
conformance with the cited codes and regulations.
The approval of the plans does not permit the
violation of any state, county or city law.
A • ~
G.) Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have
(2)
been retu,ned to you by the jurisdiction,~
to: ,!':-.:S'-1, f C.rP. 9,3Jo ch-,,sA p,41,< Or. , -"'<!..Joo/
S·P, , Ctt.-1', !id-t~ 3
To facilitate rechecking, please identify,
next to each circled item, the sheet of
the plans upon which each correction on
this sheet has been made and return this
check sheet with the revised plans.
:,t:f3
D APPLICANT COPY
D JURISDICTION COPY
D PLAN CHECKER COPY
0 FILE COPY
12,,-{. feet So,/5, rpA-.,T r,t'r,NJ--,,,.d~-r:;;,,<
OYJ A_....~ _J_ ~,,-, ,.1,-,;;-1/r 01"1 .:ShT. S-1 •
.:s.,c... f?.J./ -1 .so,/1., of.,,-~,,.,,, r1o .. ",..L. d,.ld, Is
~vc.!, "'~ , ,-~"Th i ,-1,pTT: ~i ,-b,d-•;:r
-s\(\"b r.-~ e,""~0loo, ~ "i\:",c 1..-~ • ~Tc. .
"'(ii) 'S~(, 1,1 ,r_ <:l<'H 1-,-, e~Tr, e,~ ,-;;-p,.,J.
( ~« .. 5''-/gG,,J.7') o~ ~hT.-" ~
.,. @ ouT\~i; 'o..., 'boit:"" < ,..l_ s ~-1,. House .
"'"'"' .. I
~""'"" t.ude tnu!!..lb~ ..i..t.1•aA.,T @ b-ecl u ... ,#" ,(s.1-,T . .:,). -= .., "·~ ( 1-1-4 ~ beft:",,,...., \:..rd.-""'. # ~ $-3
O>, , ~I -( I""-',, -1-i,.,... ,rt t" nle1..., I:, 01/.Pr Slr-t'.sS,.J
ii..b,....,,-1, ...
V
.,,o 5~do11I.I~ r\.o,ili u...,J,.,\C.._ \...,40J >-..,. 41.S
e)(-r,;-,..., Y W .,._,(l ✓,:;'} w, ... A ' " ? . 1:!IT 1.\.-...
1__.._.,... I ...,_°'I V, \,:,. .... -'.!,\-'"r, -S-,.>. .
V
... ff )t;L.,/1.,. ,,_.1,~_'(. ,,..,V-1::TI:c. 'fJtJl'"P~• h,., ",.1
;T;c, -(_"'T;:r,tJr ,...J '~ ,,,,,.,-L ~J-;._..,d-~ :, -3.._
,~. 1.1..,, -!r,.m,,-.,-<. tOfe..,.. $1-T. ~-.>.. •
U--e.. o}-,l.! T"t{T.rJ @ii.,,''.:,·"· !.le. .J
.... rv i)h_l .T. -1 " '!:.\..~-..,-Po. ..... l1 p, -r R-:---..
a .... ~~T--;.~~ J.~T,,._ br.a<'.'t"S CA.., c>,., I./
l-.,#us.t.J1-c1,~ ~~c:1.1. )"'o..-( ~I!',.. _,c 1,'. '!\
,r/ fi 0 ShQ...> /.Jefld~, S,7, -•n>-" w, .. ~-1d * 'S' On
r-o::d -t.,.11 m,,,~ Ple1 .....
~
"'f(T) ?rov Id f w. t"'u ('1,J .. i-'Tr<>ss e,r, 's ,
1>(/S) !-I-~ b,e:1 n1 a111,-1J;-;_ l,v, ... , y-,...,., £· .,JA~o.-1...
-;-,u((f'_s I .,."-1-r;.,,( (..,..,,.. '"7-11-r-,...,rf P/t,1,...,,~ .. ,.
ov...-~~•;,d. t-s,T.s-~,
~ <i,, :S..~ukJ A.dit'Jr,A.Tt.. l"IO"T;~~o< c..1T.(.. 4-ur-1""4.(e..
·~y 'f'rf'Zf;.1'. ouT,,,.. u ... o'b s.Tn~cTi J , -3 .., ..
,...,,Jc. PnJs.o. ~ I. 3t>" ,,,,,., Ju,-J C J~n,,,.e,~ ..
(S~c. 7c,8 V>'l C:. )
"'® p,.,,a. t:sio) (o, uf.s1a.,J .
',
Call S~DllE foll. Du,.s~ ... 5 .
41784
~
Date1 1\-5 -~(,,
Prepared by,
-s A £:>12 !,ii:
Jurisdiction Co r I~ bA. ¢,
VALUATION AND PLAN CHECK FEE
PLAN CHECK NO, ~(,,-~1.,l, I I,
CJ Bldg, Dept,
li3"Esgil
BUILDING ADDRESS M'-Cay/,,1 J..., •
APPLICANT/CONTACT µ,,~C't H,//,,r PHONE NO, 7.1,;;-,:;i~/ • I
BUILDING OCCUPANCY 'fl..:, JM, DESIGNER PHONE ------
TYPE OF CONSTRUCTION :J?',..1 CONTRACTOR PHONE_-__ ._
,;;Jr?
BUILDING PORTION BUILDING AREA VALUATI( N VALUE APfto MULTIPLIER
J-1 >/1",t Qt CA. -
c,,,,,,,,~
Air Conditioning
Commerclal
Residential
Res. or Comm.
Fire Surinklers
Total Value
Fee Adjusted To Reflect
Building Permit Fee$
_\'5( ... 0 ~~ t:Elo4o
: :
1>< ~ 17 -I : .I u
@
ca
@
_,JG:, II 'f 15
0 Energy Regulations (Fee x 1.1)
□Handicapped Regulations (Fee x 1.065)
~f_-.
/:i..: l.2.S-
~J,f/ ,; P<
J
1 · ""-'1~.oo -. WJ>'-
p lan Che ck F ee-$"------------~-------"'~'-"',._...,)_,_ • .a,.l.:•---,~<,J'/L.:('-
8/4/82
• · . PLANNING
' ZONE1 i ... \ TYPE OF PROJECT AND us6_ ...... ·_· ::::.,JI~~-_::Y •. :::;;...__-,-_____ _
SCHOOL DISTRICT: SAN DIEGUITO ENCINITAS , CARLSBAD:..;.. SAN MARCOS
•
..
GI 3' GI •-GI > ... ~~
sETBAcKs1 FRONT w sIDE u-P Rw.._df': _____ _
DISCRETIONARY ACTIDNS:__;c~b.:.,.._ __________________ _
REDEVELOPMENT PERMIT REQUIRED:,...l~ ... li..::~;;._------------------
LANDSCAPE PLAN COMMENTS1._.~~l.c~;;;.._-----------------
ENVIRONHENTAL REQUIRED:_~~J.:\~~-------------------
ADDITIONAL COMMENTS1._.,/J,u.&1)A..._ _____________ --______ _
OK TO ISSUE:._.fr---:-..::L-------DATE: U/t,/f;k.
-·· • r ·--•r ~·M" r "'"~r,.,,, ~,,, ,. ~'r •• •,-, ,. •~· --,,•~• ""r~""r ......... ----------... , ., ..... -~·-··-----..... ~----~---~-------·· . . . . -----·-· --··-·-···
ENGINEERING
LEGAL REQUIREMENTS
LEGAL DESCRIPTION VERIFIED? ~ APN CHECKED?_ ... ~.._...,._ _____ _
EASEMENTS: '2ltnN2 4'ta@◄ RIGHT-OF-WAYI ¢> ~ .t,37-V
EDU' S: J. 0 · DRAINAGE: :pee fPt I, j ~
IMPROVEMENTS I ;t b ~~ -fM,lt~~pi;#,. 1~!/f~ 4 >
HITS REQUIRED
ADING: PE i.8b.~ Me, Lfl/+1,-o?~ . -
, ___________ ' ___ ,_ GRADING COMPLETION CERTIFIED: ~~
INDUSTRIAL WASTE1 N/f?r _ DRIVEWAY1 I)(
FEES REQUIRED
PARK-IN-LIEU QUADRANT:__. __ , FEE PER UNIT: ____ TOTAL FEE: _____ _
P.F.F.~ TRAFFIC IMPACT FEE PER UNIT: #d)OO TOTAL FEE: 1:tocJD
□□
FACILITils MGMT. FEE: q.J~~ BRIDGE & THOR?UGHFARE FEE: $_
SEWER FEE (CONNECTION): ~~ SEWER LATERAL: . OJ<
ADDITIONAL COMMENTS1
~•:~, cD
1200 ELM AVENUE
CARLSBAD, CA 92008-1989
Of/le• of th• City Enr,lnHr
TO:
FROM:
DATE:
Cit!' of Carl.sbab
BUILDING DEPARTMENT / b P':::i
ENGINEERING DEPARTMENT
?-2?-.?7
ROUGH GRADING APPROVAL FOR PROJECT NO.
(TRACT or P.E. #)
/?J►S: '1-,2 F -61-r EAlt2 &<!&v, e:v L,4,,v£
(PROJECT NAME AND ADDRESS) 1
TELEPHONE
(619) 438-5541
YMN Oef«A:'-Dx:t.1./ , -<'11 IA.&1etute1< &a; CAt½<ll&>. 64-9~.r 7 > (DEVELOPER'S NAME AND ADDRESS)
We have inspected the grading for laois l/£L. L~r.S /1,S7,(? or phase __
of the above mentioned project. In addition, we have received rough
grading certification from AfN1zt:4LIA4# W6' , the Soils
Engineer, dated,4-2$-?7 , and from tv',;.u1,&,e.1.-11v lfd.,c;. ,
the Supervising Grading Engineer, dated ?-cs-?7-, , and are satis-
fied that the rough grading has been completed in accoi:dance with City
standards.
Based on these certifications and our observation, we take no exception to
the issuance of a building permit for .-.S /4.L L,,r..s Af~.ze or phase __ -of project
standpoint.
m.s: /7zP from a grading
This release, however, is not intended to certify the project
from other engineering concerns including site development, water or sewer
availability, or final grading.
Prior to the issuance of a certificate of occupancy, we need to be advised
so that we can verify that final grading and landscaping has been complet-
ed in accordance with the approved plans for the project.
APPROVED: ;t;;? e,-ct /(&;'~
roject Grading Inspector
cc: Developer
-···--~---·-·-· -----··· ---
PRELIMINARY SOILS INVESTIGATION
CITY OF CARLSBAD
PARCELS 2 & 3 MINOR SUBDIVISION 721
PARCELS 1,2,&3 MINOR SUBDIVISION 728
PREPARED FOR:
JOHN DONALDSON
2221 EL CAMINO REAL
OCEANSIDE, CALIFORNIA 92054
PREPARED BY:
WUNDERLIN ENGINEERING, INC,
504 W, MISSION AVENUE
SUITE 102
ESCONDIDO, CALIFORNIA 92025
(619) 743-2238
WUNDERLIN ENGINEERING, INC.
• • • •
October 20, 1986
PRELIMINARY SOILS REPORT
CITY OF CARLSBAD
PARCELS 2&3 MINOR SUBDIVISION 721
PARCELS 1,2,&3 MINOR SUBDIVISION 728
PROJECT DESCRIPTION:
The project consists of 5 lots ranging in size from 9,500
square feet to 10,470 square feet, The project proposes the
construction of detached single family residencial houses with
conventional two story wood framing and concrete slabs on grade.
The property is located on the North side of Elm Street, South
of McCanley Lane, between Valley Street and Monroe Street in
the City of Carlsbad, being a portion of Lot 30 of Patterson's
Addition per Map No. 565.
SITE CONDITIONS:
Parcels 2 and 3 of Minor Subdivision No. 721 are gently sloping
to the West at about 5% at an elevation of about 190 feet. The
building areas are covered with native grasses and are in a
natural state with no cuts or fills. There is an existing cut
bank along the Southerly boundary created during the construction
of Elm Street. This cut bank will not affect the proposed
construction.
Parcels 1, 2 & 3 of Minor Subdivision No. 728 are sloping Easterly
at slopes ranging from 2% to 50%. There is a ravine and drainage
course which runs between Monroe Street and the Easterly boundary
of said Parcels 1, 2 and 3, Much of the property has been used
as a dumping site for landscape trimmings, asphalt and other
debris. All of this material will be required to be removed
from the site.
SOILS CONDITIONS:
The soils on all five properties consist of grey silty sand to
sandy soi 1 s.
An area of Parcel 1, 2, & 3 of Minor Subdivision No. 728, as
504 W. MISSION AVENUE, SUITE 1 02, ESCONDIDO, CA 92025 e (61 917 43-223B
PRELIMINARY SOILS REPORT
CITY OF CARLSBAD
page 2
SOILS CONDITIONS: (Continued)
shown on the attached plat map, has uncompacted fills which will
require removal and recompaction.
FIELD INVESTIGATION:
A field investigation was made on October 11, 1986. Five trenches
were dug, as shown on the attached plat map, using a backhoe with
a 24 inch bucket. The soil types were uniform, consisting of
grey, silty sand. There were no expansive clays found on the site.
Ground water was not encountered.
The following is a log of the soil stata found in the trenches
shown on the attached plat.
TRENCH DEPTH DESCRIPTION
T-1 surface s i 1 t y sand
0 -3 s i 1 ty sand
T-2 surface debris
0 -2 debris
2 -5 s i 1 t y sand (uncompacted
5 -8 s i 1 t y sand
T-3 surface debris
0 -2 debris
2 -4 s i 1 t y sand (uncompacted
4 -8 s i 1 ty sand
T-4 surface debris
0 -1 debris
1 -4 s i I t y sand (uncompacted
4 -8 s i 1 t y sand
T-5 surface debris
0 -1 s i 1 ty sand (uncompacted
1 -5 s i 1 t y sand
f i 1 1 )
f i 1 1 )
f i I 1 )
f i 1 1 )
PRELIMINARY SOILS REPORT CITY OF CARLSBAD
page 3
CONCLUSIONS AND RECOMMENDATIONS:
1. All debris shall be removed from the site.
2. All on-site fills shall be removed and recompacted under
the supervision of a qualified civil or soils engineer.
3. Attached is a copy of the Recommended Grading Sepcificatlons.
4. It shall be the discretion of the soils engineer to modify
the required site preparation as site conditions require.
5. The footings shall be 1611 by 24" with tow #4 bars, one at
the top and one at the bottom. The slabs shal 1 be 4 11 of
concrete with 6x6, 10 gage wire mesh over 2" sand, over a 10
mil. vapor barrier.
k
Michael A.
RCE 26671
Date
\ I
I I
\
\
I
I I-
I I UJ
I
(J/
/
I Ci
I
I-
I
I 1/)
I
I
\.I) I
2 I
I
a: '
I ~ I ..J
_J
rt) l:U
.J
7 \II
uJ M --
...)
-r-3
-I
~ '1 1-\
C. ~
u
'-' I
-IP ~
~
rJ ~
~<
J "' ,:-,q'/j, . ~
~ ,J.
!Y
ci
I-
.-· 4::
2
\)
,::.. i:,.. = --
/
•
RECml.MENDED GRf,T)ING SPF.CH [CATIONS -GENERAL l'ROVISTONS
General Intent
The intent of these specifications is to establish procedures
for clearing, compacting natural ground, preparing areas to
be filled and.placing and compacting fill soil to the lines
and grades shown on .the accepted plans. The recommendations
contained in the preliminary soil investigation report
nnd/or Lhe attached Speci.:il Provi,,i.ons are a part of the
Recommended Grading S.;,ecifications and shall supersede the
provisions contained hereinafter in the case of conflict.
INSPECTION AND TESTING
J\ qualified soil engineer shall be employed to inspect and
test the earthwork in accordance with these specifications.
It will be necessary that the soil engineer or his representative
provide adequate inspection so that he may certify that the
work was or was not accomplished as specified. It shall be
the responsibility of the contractor to assist the soil
engineer and to keep him appraised of work. schedules, chances . -
and new information and data so that he may make these
certifications.
If, in the opinion of the soil engineer, substandard conditions
are encountered, such as question~hle soil, poor moisture
cont r•ril., l11,-,,lnq11nt·n ,•rJl11J1IH!I' Ion, 11dv11rn,i WP:tl hPr, nl P., lu•
will be· empowered to either stop construction until the
conditions are remedied or corrected or recommend rejection
of the work.
/
Soil tests used to determine the degree of compaction will
be performed in accordance with the following American
Society for Testing and Materials test met~ods:
Maximum Density & Optimum Moisture Cohtent -A.S.T.M.
D -1557 -70.
nrn!:lity or Roil In-l'l11cc -/\.S.1'.M. n -1556 -r.4.
PREPARATION OF AREAS TO RECEIVE FILL
All vegetation, brush and debris shall be removed, piled and
burned or otherwise disposed of. After clearing, the natural
ground shall be scarified to a depth of 6 inches, brought to
the proper moisture content, compacted and tested for the
minimum density specified in the Special Provisions or the
recommendation contained in the preliminary soil investigation
report.
When the slope of the natural ground receiving fill exceeds
20% (5 horizontal units to 1 vertical unit), the original
ground shall be stepped or benched. Benches shall be cut to
a firm competent soil condition. The lower bench shall l:e
at least 10 feet wide and all other benches at least 6 f€et
wide. The horizontal portion of each bench shall be compacted
prior to receiving fill' as specified herein before for
compacted natural ground. Ground slopes flatter than 20%
shall be benched when considered necessary by the soil
engineer.
FILL MATERIAL
Materials placed in the .fill shall be approved by the soil
engineer and shall be free of vegetable matter and other
d~leterious suhstan~es. GranulRr snil shall con~atn sufficient
/
fine material to fill the voids. The definition and disposition
of oversized rocks, expansive and/or deterimental soils are
covered in the Special Provisions. Expansive soils, soils
of poor gradation-or strength characteristics may be thoroughly
mixed with other soils to provide satisfactory fill material,
but only with the explicit consent of the soil engineer.
PLACING AND COMPACTION OF FILL
Approved fill material shall be placed in areas prepared to
receive fill in layers not to exceed 6 inches in compacted
thicknt'ss. 1'nch lnycr shall have a uniform moisture content
i11 the range that will allow the compaQtion effort to be
efficiently applied to achieve the specified degree of
compaction. Each layer shall be uniformly compacted to a
minimum specified density with adequately sized equipment,
either specifically designed for soil compaction or of
proven reliability. The minimum degree of compaction to be
achieved is specified in either the Special Provisions or
the recommendations contained in the preliminary soil investigation
report.
Field tests and inspections_ to check the degree of compaction
of the fill will be taken by the soil engineer or his representative.
The location and frequency of the tests shall be at the soil
engineer's discretion. In general, the density tests will
be made at an interval not exceeding 2 feet in vertical rise
and/or 500 cubic yards of embankment.
SEASON LIMITS
Fill shall not be placed during unfavorabl~ weather conditions.
When work is interrupted by heavy rain, filling operations
shall not be resumed until the proper moisture content and
' .
density of the fill has been achieved. Damage resulting
from weather shall be repaired before acceptance of work.
UNFORESEEN CONDITIONS
In the event that conditions are encountered during the site
preparation and construction that were not encountered
during the preliminary soil investigation, a soils engineer
shall consulted to evaluate the situation and make recommenda-
tions before additional work Is done,
RECOMMENDED GRADING SPECIFICATIONS
SJ>ECIJ\f, J>ROVISIONS
The minimum degree of compaction to be obtained in compacting
natural ground, in the compacted fill, and in the compacted
backfill shall be 90 percent.
Detrimentally expansive soil is defined as soil which will
swell more than 3 percent against a pressure of 150 pounds
per square f.oot from a condition of 90 percent of maximum
dry density and optimum moisture content to saturation.
oversized fill material is defined as rocks or lumps over 6
inches in diameter. At least 40 percent of the fill soil
shall pass through a No. 4 U.S. Standard Sieve.
Transitiion Lots: Where transitions between cut and fill
occur within the proposed building pad, the cut portion
should be undercut a minimu~ of one foot below the base of
the proposed footings and recompacted as structural backfill.
SCHOOL FEE COMPLIANCE CERTIFICATION
(Government Code Section 53080(b))
This form shall be used to determine the amount of school fees for a project and
to verify that the project applicant has complied with the school fee requirements.
No building permits for the projects shall be issued until the certification is signed
by the School District and returned to the Building Department of the City of Carlsbad.
PROJECT INFORMATION (To be completed by the applicant)
Project Address: /8c/6 /?J c-c..e_'-L~ ':J.. L_/V
Project Applicant: R o ber .,-'C:>9.vs..-{J'.M,v
Project Type: ~esidential/No. of Dwellings Commercial Industrial
Phased Project: _Yes ~o.
Building Permits are for entire project ~es No.
Square feet of covered or enclosed space ~4?0 ~~lit¼ ·725.~
Plan check or Building Permit No. -~B::i.._..C.._-___;::S"" ...... ,~'-------------
Official checking form :(' j/4r{<, Date :2 -13-~7
INFORMATION VERIFICATION (To be completed by the project applicant)
I, O('\rurl \\:u:Y1:lds~ h ' declare under penalty of perjury under
the Laws cJ the State of California that I am the project applicant for the project
listed above and that the foregoing information is true and correct. !
Executed this \1 day of . Fen\'ih('i/ ' 198_J, at __._C...,ai1.-1-r~l<.......a...hl_e ___ _
California. 7
FEE CERTIFICATION (To be completed by the School District)
__L Applicant has complied with fee requirement under Government Code 53080.
Project is subject to an existing fee agreement.
Project exempt from Government Code 53080.
Final Map approval and construction started before September 1, 1986.
(other school fees paid)
Other
School District Official:
DATE
(ts 1~) -<--\3iJ-.t~ClolU
NAME (PRINT) PHONE NO.
\\~s"'t"--ro~\. ~os -~,0\c e~
TITLE
~ARLSBAD UNIFIED SCHOOL DISTRICT
□ CARLSBAD HIGH SCHOOL
□ VALLEY JUNIOR HIGH SCHOOL
RECEIVED FROM ~ cl X\o 'k \. b ~"-.o....U s CO\
1l'"-\S {n{ ('o.~o.r<\Q. \ &'~ • ~. S Go ~
FOR:t~V1° G~<-~e.:-;_;_~~ X f).SO
USE OF SCHOOL FACILITIES/RENTALS $ _____ ;~~~\~TS
USE OF SCHOOL BUS $ ____ _
DAMAGE TO SCHOOL PROPERTY $ ____ _
DAMAGED OR LOST BOOKS $ ____ _ INSURANCE
RECEIPT NO.
1386 2
DATE ~\d-t) \ ~1
$ ____ _
SALE OF SURPLUS $ ____ _
INCOME EJ' ABATEMENT 0
TELEPHONE COMMISSIONS $-----
TOTAL $ .l\ q;;).. ~-
ACCOUNT NO. L -1?8"91 -----
ACCOUNT NO. -----
ACCOUNT NO. ------
~ aq :\.
RECEIVED CASH □ CHECK EJ
RECEIVED BY °N)<l\l\n" ~-G'l\ \~.,,c~ 1 ---,-