Loading...
HomeMy WebLinkAbout1857 PENTAS CT; ; CB141959; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08-22-2014 Cogeneration Permit Permit No:CB141959 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 1857 PENT AS CT CBAD COGEN 2155210500 $8,400.00 Sub Type: PHOTO Lot#: 0 Constuction Type: NEW Reference #: STEVENS RES-PHOTOVOLTAIC SYSTE Status: ISSUED Applied: 08/07/2014 Entered By: RMA Plan Approved: 08/22/2014 Issued: 08/22/2014 Inspect Area: Plan Check #: 21 ROOF MOUNTED MODULES -UPGRADE ELECT PANEL FROM 100 AMPS TO NEW 200 AMP PANEL Applicant: SULLIVAN SOLAR POWER OF CALIFORNIA INC STE 101 8949 KENAMAR DR SAN DIEGO CA 92121 858-271-7758 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Green Bldg Stands (SB1473) Fee $117.07 $0.00 $81.95 $68.05 $0.00 $1.00 $1.00 Owner: STEVENS SPENCE L&SUE J 1857 PENT AS CT CARLSBAD CA 92011 PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Additional Fees TOTAL PERMIT FEES Total Fees: $269.07 Total Payments To Date: $269.07 Balance Due: Inspector: FINAL APPROVAL Date: q-/u -/'/ Clearance: $0.00 $0.00 $0.00 $0.00 $269.07 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reseNations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure w\11 bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: □PLANNING 0 ENGINEERING □BUILDING □FIRE OHEA1TH 0 HAZMAT/APC0 «'"' Building Permit Application Plan Check No. r-; l / 4 /t/(CI 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value AU/WJ .. f ~ CITY OF Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Dep lllt' CARLSBAD email: building@carlsbadca.gov (l,i-www.carlsbadca.gov Date X/, /LI lswPPP JOB ADDRESS 1857 Pentas Ct SUITEf/SPACE#/UNIT# I'"" 215 -521 -05 -00 CT/PROJECT# I LOT# I PHASE# I# Of UNITS I# BEDROOMS # BATHROOMS rENANT BUSINESS NAME I CONSTR. 1YPE I occ. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(•) Roof Mount PV with 21 Modules and Electrical Panel Upgrade From 100A ta12&,A _ .;)ill~ EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE AIR CONDITIONING I FIRE SPRINKLERS YES0, N<O YES □No □ YES□No□ APPLICANT NAME Oscar Alvarado PROPERTY OWNER NAME Spence Stevens Plt1arv Contact ADDRESS ADDRESS 8949 Kenamar Dr. STE 101 1857 Pentas Ct CITY STATE ZIP CITY STATE ZIP San Dieao CA 92121 Carlsbad CA 92011 PHONE IFAX PHONE IFAX 858-357-3179 858-271-7759 760-402-0896 EMAIL EMAIL Oscar.Alvarado@lSullivanSolarPower.com DESIGN PROFESSIONAL CONTRACTOR BUS. NAME Sullivan Solar Power ADDRESS ADDRESS 8949 Kenamar Dr. STE 101 CITY STATE ZIP CITY STATE ZIP San Dieao CA 92121 PHONE PHONE l'AX 858-271-7758 l'AX 858-271-7759 EMAIL EMAIL info@lSullivanSolarPower.com I STATE LIC. # STATE UC.# I CLASS I CllYBUS. LIC.1226671 839077 C-10 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any: structure, prior to its issuance, also requires the applicant for such permit to flle a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section ?031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one oft/le following cieclarations: D I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this perm rt is issued. [Z] I have and will maintain workers' compensation, as reauired bv Sectton 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co Cypress Insurance Policy No. 3300060354-11 Expiration Date 12/0112014 ~section need not be completed if the permit is for one hundred dollars ($100) or less. U Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to sec;ure workers' compensatio coverage Is u awful, and shall subject an employer to criminal panalties and cMI fines up to one hundred thousand dollars (&101, 0), In addition to the cost of compensation, damages as provided n Section 37 fthe Labor code, 1:ter~tand attorney"s fees. C/' .. ,,_-, .. { .IE5 CONTRACTOR SIGNATURE (Z]AGENT DATE D C I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ □ □ I, as owner of lhe property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exdusively contracting with licensed contractors to construct the project (Sec. 7044, Busiriess and Professions Code: The Contractor's License Law does not apply lo an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section ____ ,Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of ttie proposed property improvement. 0Yes 0No 2. I (have I have not) signed an application for a building permit for ttie proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address I phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address/ phone/ type of worll): .JE5 PROPERTY OWNER SIGNATURE □AGENT DATE ' ' ! : COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes D No Is the applicant or future building occupant required to obtain a permit from the air pollution control disbict or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ~(!;,'~Ill ST RU C Tl ON LENDING AGENCY I hereby affirm that there Is a construction lending agency for the pertormance of the work this permit Is issued (Sec 3097 (1) C1v1I Code) lender's Name lender's Address 1/A~~LI CA NT CE RTI FI CATION I certify that I have read the application and state that the above lnfonnatlon Is correct and that the lnfonnation on the plans Is accurate. I agree to comply'Mth all Clfy ordinances and State laws relating to building construction, I hereby authorize represeotative of the City of Carlsbad kl enter upon the above mentioned property for inspecli:>n purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILrTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AG,OJNST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: All OSHA permit is required for exr.avations over 5'0' deep and demolb or conslrucoon of structures over 3 stories in hef'Jhl. EXPIRATION: Every pennit issued by the Building Offbal under the provis" oflhis Code shall expi"e by limilaOOll and become nul and YOO W lhe building or work authorized by such permit is not oommenced 'Milin 180 days from the date of such permit or if the buidhg or work authorized perml · s nded or ab:ndoned at any line after the work is conmenced ~jood of 180 days (Secoorl 106.4.4f ,,n'mn Building Code) . ...s APPLICANT'S SIGNATURE d=s:s~'=r~~= · DATE o . t · / Lf Inspection List Permit#: CB141959 Type: COGEN PHOTO Date Inspection Item Inspector Act 09/12/2014 35 Photo Voltaic (PV) RI 09/12/2014 35 Photo Voltaic (PV) PB AP 09/12/2014 39 Final Electrical PB AP 09/10/2014 33 Service Change/Upgrade PB AP 09/10/2014 39 Final Electrical RI Tuesday, September 16, 2014 STEVENS RES-PHOTOVOLTAIC SYSTE 21 ROOF MOUNTED MODULES -UPGRAD Comments 12-2 PLS Page 1 of 1 .. EsGil Corporation In <Partnersnip witn qovernment for rJJuiUing Safety DATE: 08/15/2014 JURISDICTION: Carlsbad PLAN CHECK NO.: CB14-1959 PROJECT ADDRESS: 1857 Pentas Ct. SET: I PROJECT NAME: Stevens 6000 Watt Solar Photovoltaic System • D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. [gl The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [gl Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person E-mail: [gl REMARKS: Applicant to see sheet PV-3 clouded area, applicant to make changes to all city held sets prior to issuing the permit By: John Le Vey EsGil Corporation □GA □EJ □PC Enclosures: 08/11/2014 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CB14-1959 08/15/2014 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: John Le Vey BUILDING ADDRESS: 1857 Pentas Ct. BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier PV svstem Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance ---------------------------.... Plan Check Fee by Ordinance -~ Type of Review: □ Complete Review 0 Repetitive Fee -_·3 Repeats • Based on hourly rate Comments: 1.5 hour plan review. D Other O Hourly EsGII Fee PLAN CHECK NO.: CB14-1959 DATE: 08/15/2014 TYPE OF CONSTRUCTION: Reg. VALUE ($) Mod. D Structural Only 1--___ 1_.--151 Hrs.@• $86.00_ $129.001 Sheet 1 of 1 macvalue.doc + <<1 ~ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 8/7/14 PROJECT NAME: SOLAR PANELS PROJECT ID: Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.c;:1rl.c.br1dc;:i.11ov PLAN CHECK NO: CB141959 SET#: ADDRESS: 1857 PENTAS CT APN: C8J This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required D Yes i:,g No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 □ Chris Sexton □ Kathleen Lawrence □ Greg Ryan 760-602-4624 76Q-602-27 41 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawr11nce@carlsbadca.gov Gregory.Ryan@carlsb~dca.gov □ Gina Ruiz □ Linda Ontiveros □ Cindy Wong 760-602-4675 760-602-2773 76Q-602-4662 Gina.Ruiz@carlsbadc,!.gov Lind,!.QntiverQs@Qarlsbadca.gQv Qynthla.Wong@Q,!rlsbadca.gQv □ □ □ Dominic Fieri 76Q-602-4664 DominiQ.Fieri@carlsbadca.gov Remarks: sos." ..,.JE A ~ Sempra Energy utility ELECTRIC UNDERGROUND METER & SERVICE LOCATION Customer Copy Wanted Date: Service Type: UG Service Rewire Project No: 456273 I Job No: 010 Project Title: STEVENS RESIDENCE (SOTI (SOLAR) Project Address: 1857 PENT AS CT Project Citv: CARLSBAD I Customer Phone #: contact: SUE STEVENS I Contact Phone #: 760-402-0898 D Traffic Control Permit Required. Excavation/Encroachment Permits Required By Customer Service Attachment Point and/or Meter Location: Install new 200-amp meter panel on the South wall at the existing panel location. Customer is to provide all excavation, trench, 2-inch conduit, backfill, compaction, 3/4" pulling and measuring tape in conduit and surface repair from hand hole to new meter panel. "Pre-Meet Required with SDG&E Trench Inspector Prior to Trenching". Call SDG&E Wendy Jensen at 760-476-5611 to schedule a morning disconnect with an afternoon reconnect provided that the City/County releases inspection to SDG&E by 2:00 PM on the same day the crew is scheduled. To avoid delays with reconnection, your permit should read (Customer Outage Involved). Please contact the Net Energy Metering Team at: (858) 636-5585 regarding in1:bll:dinn of ~ 0 SDG&E Application Required -Call: 1-800-411-7343 Municipal Inspection Re<iuired Bv Citv of Carlsbad Meter height -4'0' min. (3'0' min. for multiple meter instaDation) -6'3' max. From finish grade to centerline of meter base. Meters are required to be readily accessible 24 hours per day. Meters must be localed in a safe area free of any potentiaRy hazardous or dangerous condition. Provide ~ft. X ~ Minimum dear and level working space in front ol meter. Where meter room is proposed, contact the planner al the nearest SDG&E office. Meter bases and meter 581Vice disconnects must be located at or immediately adjacent to each other and be identified with address and unit number It serves. PROCEDURE FOR INSTALLATION 1. PHONE DIG ALERT 1-800-227-2600 AT LEAST TWO DAYS PRIOR TO TRENCHING FOR LOCATION OF UNDERGROUND UTILmES. 2. Phone SDG&E at 760-476-5611 for the following: • 3 working days prior to trenching to arrange pre-meet with inspector and initiate trenching process . • After excavation of trench, installation of conduit and service entrance equipment at meter location, CALL FOR INSPECTION. Do not cover conduit without inspector's written approval to backfill. . When trench is backfilled and compacted, CALL FOR INSPECTION . . If service entrance equipment is installed after backfill, CALL FOR INSPECTION OF THE EQUIPMENT. 3. Meter cannot be set until inspector has approved installation, including service equipmen~ and receipt of citv/countv/state insoection clearance. Power Source: 755-135 I structure Number: EXISTING 3312 HANDHOLE Joint Trench with: Electric Onlv Handhole Installed bv: Bend Installed by: Customer Tvoe: Handhole 2" 90 Dea 24"R DB60 Conduit Installed by: Customer Conduit Size: 1 • DB 2" Service Panel Rating: 200 Number/Size of Main Switch: 1 /200 Voltage: 120/240 #of Wires: 3 Phase: Sinale Utilities Maximum Contribution to Fault Current 10000 Amps Metering: Self-Contained Meter Clips: 4 Temp Service Charge Due on First Bill$ T.B. 1127-E6 CustomerType: Residential Date Prepared: 06/09/2014 N I ~½ ~"~.<;--.... ~ g:,'t; -\">41 '>7 <::,~ ..... cl'-"I ·-'O -~-~-1 -.. ---..__ --<) .... ,~l 'o / <) --,..__ e-"' -----' _,:y c::::,. J. ,;,'<" PL:, °" .--. 'N-.....1 \ -...., , ... ,~ XSTc MANZANIT~ EXISTING 3312 HANDHOLE ,s.<)I>, ~~ '<> I \ ' I I Additional Information: D Right-of-way Required Assessor's Parcel Number: 1857 Please call your Service Coordinator Wendy Jensen at 760-476-5611 with questions about application, inspection, construction installation and to schedule a crew. City/County inspection will have to be received prior to 2:00 p.m. on the same day as the disconnect to allow SDG&E crew enough time for reconnection of service on the same day. ~ SOG&E encouiiiars hazardous or toxic material while perlorming cons1rudion of yr,s project. SOG&E wil halt -ilvnediately and It wil be yr,s responsibity to remove and/or dean up al hazardous or toxic material prior to SOG&E a,ntinuing ccnstruction. SOG&E ,hall have no iabity or obigation whatsoever to dean up, remove or remediate any hazatdous or toxic materials discovered during the course of ccnstruction unless It is thl!>IJ9'1 negligence of SOG&E. Cus1omer-owned faciities to receive eledrical service are subject 10 al applicatle local and state of caritornia inspection au1hority requnments. Btilding address and/or meter basa ITTJsl be posted prior to meter sel Information on 111s sheel is ><>id afler six (6) months from date. Kffl) this notice with building pemit. Al lnslalalions pe<fooned ooder this order ITTJsl meet SOG&E s~ards unless a written d8'iation has been approved. Planner: AMY P MCBROOM Telephone: 760-476-5610