Loading...
HomeMy WebLinkAbout1858 BUENA VISTA WAY; ; CB010899; Permit03/05/2001 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 Miscellaneous Permit Permit No:CBOI 0899 Job Address: Permit Type: MlSC Subtype: OTHER Status: ISSUED Parcel No: 1561 523500 Lot #: 0 Applied: 03/05/2001 Valuation: $0.00 Entered By: JM Reference #: Plan Approved: 03/05/2001 Issued: 03/05/2001 Project Title: CREST - DEMO EXIST SFD 832SF Inspect Area: 1858 BUENA VISTA W CBAD Applicant: MSK MANAGEMENT, INC. &ELEANOR GRACE TRS 2141 PALOMAR AIRPORT RD l? Q E 1 03/05\01 0002 01 02 CARLSBAD, CA 92009 CEE. 30 a OQ JAMESTOWN CA 95327 61 9-929-0799 Total Fees: $30.00 Total Payments To Date: $0.00 Balance Rwe: $30.00 Miscelaneous Fee #I $3 Miscelaneous Fee #E $ TOTAL PERMIT FE FINAL APPROVAL Inspector: Date: Clearance: ______ NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as Yeeslexactions." You have 90 days from the date this permit was issued to protest imposition of these feedexactions. If you protest them, you must follow the protest procedures set forth in Government Code Seclion 6602O(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specifhi fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or sewice fees in connection with this project NOR DOES IT APPLY to any feedexactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. . PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO.W//ZT EST. VAL. Date Address (include BldglSuite I) Legal Description Lot No. Subdivision NamelNumber Unit No. Phase No. Total # of units Assessor's Parcel t Existing Use Proposed Use Business Name (at this address) PM 0255.3 ( PfiR q) I - 5 NONC N&J Cads S3L I d. I issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codal or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). Name Address ' EI nOM BNT !Ti92 AVEWA E State License t 1,Ja 7 zd Designer Name Address City Statelzip Telephone 0 I have and will maintain a certificate of consent to self-insure for workers' compensation es provided by Section 3700 of the Labor Code, for the performance of e work for which this permit is issued. d I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: insurance Company S+ #C nj nA Policy No. fl - 17 4 I& - 0 Expiration Date )o I )d 2 [THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [blOOl OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify thet in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: FaLm to amre workers' cornpansation coveraga Is unlawful. and shall subject an employer to cfimkrrd penalties and cMI finas up to om hundred thousand dollara ~$100,000). h addltlon to the cost of compensation. damagas as pr0vld.d for in Section 3706 of the Labor coda, Interest and attorney's fees. owing reason: L 0 I, as owner of the property or& employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided thet such improvements ere not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). c] 1, es owner of the property, am exclusively contrecting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 1. 2. 3. I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0 I (have / have not) signed an application for e building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address / phone number I contractors license number): Business and Professions Code for this reason: 4. number / contractors license number): 6. of work): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone number I type T Is the applicant or future building occ&Sant re uired to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25605, 25533 or 255 4 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 0 YES I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state thet the above information is correct and that the information on the plans is accurate. I agree to comply with ell Cky ordinances and State laws relating to building construction. I hereby authorize representatives of the at). of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is APPLICANT'S SIGNAT ~7/&4WL. February 21 , 2001 CITY OF CARLSBAD 1635 Faraday Avenue Carlsbad, CA 92008 sent via: Hand Delivery RE: Crest Propertv, Carlsbad. CA To Whom It May Concern: MSK Development Group (MSK), is a general partner for the Crest imited Partnership. MSK, pursuant to the partnership agreement is empowered to act and represent the Partnership in all matters with respect to demolition, grading, and construction of the homes. Therefore, MSK can act for the owner in the removal of the existing improvements located on 1858 Buena Vista Way, in the City of Carlsbad. Since ret y , MSK DEVELOPMENT GROUP President JAG:jef 5142 Avenida Encinas, Carlsbad, CA 92008 (760) 931-2785 Fax (760) 931-2784 City of Carlsbad Bldg Inspection Request For: 09/26/2001 Permit# CBOI 0899 Inspector Assignment: /1 c/3 Title: CREST - DEMO EXIST SFD 832SF Description: NO NEW CONSTRUCTION Type: MlSC Sub Type: OTHER 1858 BUENA VISTA WY Job Address: Location : Suite: Lot 0 APPLICANT MSK MANAGEMENT, INC. Owner: SMITH DALE WALKER&ELEANOR GRACE TRS Remarks: Phone: Inspector: 17 C& Total Time: Requested By: NA CD Description I9 Final Structural Entered By: CHRISTINE Act Comments Associated PCRs Date InsPection History Description Act lnsp Comments Mar 05 01 01217~ Magnus Lcapold b # 858-793-1236 March 5, 2001 Mr. Shad Mix MSK Development Group 5742 Avenida Encinas Carlsbad, CA 92008 Dear Mr. Mix: TEST Environmental Surveys and Testing was retained by MSK Development Group to provide asbestos abatement monitoring (site surveillance) and clearance air sampling during the removal of asbestos containing materials at 1858 Buena Vista Way in Carlsbad, California. were conducted on February 28 to March 5, 2001 by Mr. Magnus Leopold, Certified Asbestos Consultant from TEST. The asbestos abatement monitoring and clearance air sampling The asbestos abatement was conducted by Abatement Service Operations, Inc., I68 Miller Avenue, El Cajon, California. I. ASBESTOS ABATEMENT LOCATION The asbestos abatement was conducted at the following locat ion : 1858 Buenli Vista Way, Carlsbad, California 1. Floor tile - (12"x12") tan w/ floral pattern - in Kitchen (mastic negative for asbestos). Floor tile and mastic underneath above tile was also negative for asbestos. 2. Roof - Asphalt sealing compound (black) on wood boards of roof below layers of asphalt roof tile, asphalt She& (vapor barrier), and Mood shingles (house + garage + backyard building). 3. Roof to crawlspace - transite ventilation pipes (3 pipes) (one from crawlspace to attic, one in attic, one in crawlspace). 4. Roof - miscellaneous asphalt penetration mastic (black) around pipes and chimney (house + backyard building) 1 Mar 05.01 01:18p Magnus Leopold ,, ? p 7. 858-793-1236 P- 3 11. ASBESTOS ABATEMENT PROCEDURE A. Floor tiles - (12"X?2") - tan (floral pattern) - Kitchen 1. Set-Up and Removal Procedures Critical barriers of plastic were put up on the windows, doors, and other penetrations to contain the area. A one stage decontamination unit was built at the front end of the Containment and a negative air unit was attached to the back end. The negative air machine (containing HEPA filtration system) exhausted the air from the containment area to the outside of the building. OSHA asbestos warning signs were placed on the containment plastic and also on the entrance to the decontamination unit. Barrier tape was put up to define the abatement area and to keep unauthorized personnel away from the abatement activities. The floor tiles were wetted using a Hudsen sprayer and then removed using long handled tile scrapers. The floor tiles were removed from containment using "bagout" procedures and placed in the waste dumpster. Following the removal of the floor tiles, the Industrial Hygienist from TEST inspected the containment area for asbestos and gave a visual clearance. AS0 then sprayed the containment with a lockdown encapsulant. B. Roofing - Asphalt Sealing Compound Layer (on wood roof) (house + garage + backyard building) 1. Set-Up and Removal Procedures A waste dumpster was double lined with plastic sheeting. A one stage shower was erected as a decontamination unit. OSHA asbestos warning signs and OSHA asbestos barrier tape were placed around the house. The top layers of the roof (wood shingles and asphalt sheeting (vapor barrier)) were removed from the roof. The plastic dropsheets were then placed around the house and in the attic. The asphalt roofing tiles and asphalt sealing compound which was on top of the "hot mop" was removed cleanly from the wood roof. The wetted larger pieces were placed directly in a double lined dumpster and the wetted smaller material placed in plastic bags and then put into the dumpster. by prying up the nails holding the tiles. roof was then detail cleaned and the drop sheets removed and disposed of in the waste dumpster. The asphalt roof tiles were removed using long handled scrapers The asbestos containing material is considered non-friable. The 2 TEST ENWRONMENT'AL SURVEYS AND TESnNG Mar 05 01 01:18p Magnus Lsopold .. , 858-793-1236 C. Transite Ventilation Pipes The transite ventilation pipes (3) from the roof to the crawlspace were removed removed by loosening the metal straps holding them in place, and then sliding the pipes out through the roof. The transite pipes were wrapped in 6 mil plastic and then placed in the waste dumpster. 4. Roof - Miscellaneous Asphalt Penetration Nastic Miscellaneous asphalt penetration mastic around the pipes going through the roof and around the chimney were removed by removing the metal aprons at each location and placed in the waste dumpster. 111. ABATEMENT PERSONNEL AND PROTECTIVE EQUIPMENT Abatement Service Operations, Inc. personnel involved in the ACM removal were Enrique Flores, Jose Salas, Francisco Soto, and Jose Moreno. The certifications for worker asbestos removal training, medical clearance, and respirator fit testing were reviewed and are included in this report. Abatement Service Operations, Inc. personnel wore full protective equipment during removal which included Tyvek suits (with attached hoods and boots), and half-face respirators with HEPA cartridges. IV. CLEARANCE AIR SAMPLING The clearance air sample was collected in the Kitchen containment area and analyzed by phase contrast microscopy (PCM). Phase Contrast Microscopy (PCM) Sampling Procedures The air samples were taken using a Dawson high volume air sampling pump connected to a plastic cassette with a two inch anti-static cowl and 25 millimeter 0.80 micron mixed cellulose ester filter (MCEF) at a flow rate of approximately 15 liters per minute for approximately 1 1/2 hours. Phase Contrast Microscopy (EM) Analysis Method The air samples were analyzed according to National Institute of Occupational Safety and Health (NIOSH) Method 7400A by a National Voluntary Laboratory Accreditation Program (NVLAP) laboratory. 3 TEST ENVIRONMENTAL SURVEYS AND TESTING Mar 05. 01 01:18p Magnus Lcopold 858-793-1236 V. RESULTS OF CLEARANCE AIR SAMPLING The PCM clearance air sample (ML0228-1) taken in the Kitchen containment area after asbestos abatement had an asbestos fiber concentration of less than 0.003 fibers per cubic centimeter (<0.003 f/cc). area to be re-occupied following asbestos abatement (0.01 fibers /cc) (See TABLE 1). The clearance air sample was below EPA's guideline allowing an If there are any questions concerning this report, then please call me at any time. Very truly yours, Magnus +- Leopold Industrial Hygienist General Manager I Certified Asbestos Consultant Cert. NQ. 93-1124 I 4 TEST EWRONMENTAL SURVEYS AND TESTING Mar 05 01 01:19p Magnus Leopold TABLE 1 SUMMARY OF AIR SAMPLING RESULTS CLEARANCE AIR SAMPLE (PCM SAMPLING) 1858 Buena Vista Way, Carlsbad, California MLO228-1 Kitchen 11:43 1:23 pm 15.20 1520 <0.003 - middle 5 n .. c c 9 CI n .. plodoal snulow .. 3 11 -. sg 3 0 5' ? 2 Ro l-3 (D g fo! 0 .. 'to so a=lJ 3- 4-01; B:ZlPM; ;7604807666 1 1/ 1 - SOSEC NOTICE OF SERVICE DISCONTINUANCE THlS 8UluHIYO CAN BE MOVED OR RAZEb AFTER THE ABOVE DATE. .. * City of Carlsbad a DEMOLITION PERMIT REQUIREMENTS Igl 6. A demolition permit may only be issued to the owner of the property or the State Licensed Contractor that is doing the work. The contractor must provide use with a letter, signed and dated by the property owner, giving permission for the building to be demolished. --1 sb H The fee for a demolition permit is $30.00. The attached Demolition Asbestos Certification application must be completed, signed and have the correct square footage of the structure being demolished, as well as it’ s use. AS-s 8fir~1- VIMT.J, p)iqfot n+e~ -Jd 7-E 34-9’s a El Applicant must provide a letter from San Diego Gas and Electric stating that the utilities have been disconnected. A a//z/04 -- smfs 70 &Sca.W4d%s- Arrange for appropriate Water Authority to remove water meter unless construction of replacement structure is to begin shortly. H B OK Coastal Zone, or if it is on the list of Carlsbad Historic Sites. 8~ Contact the Planning Department at (760) 602-4625 or 602-4629 to determine if the structure is in the Redevelopment area, if it is in the X- Contact the Engineering Department at (760) 602-2775 or 602-2741 to determine if a Haul Route or Right-of-way Permit is required.. Notify the Fire Department at (760) 602-4660 to see if they need the use of the building for training purposes. 1F &p&@ /;r * odd bH ,‘J H bc wi- %ck (UFI~UAUZAW~ q31--lz3> -wLb hhf To ?b 97w5 cL&* i:\wordforms\buiIding\dernolition permit requirements.doc REV August 9,2000 1635 Faraday Avenue Carlsbad, CA 92008-731 4 (760) 602-2700 FAX (760) 602-8560 @ * - City of Carlsbad DEMOLITION ASBESTOS CERTIFICATION ADDRESS: I0gB Bw USE OF BUILDING TO BE DEMOLISHED: d Ed C@I&~~~ SQUARE FEET 03% X NUMBER OF STORIES 1 PROPERTY OWNER: CUW Lafd LP *I, b ADDRESS: $142 wdlm f&&de # APPLICANT: rrl PHONC7ba) 931 27r ADDRESS: 5142 -1 bb Ufi PHON^?^^! 8W- 2bzr .................................................................................. Section 19827.5 of California Health and Safety Code states in part: ‘fi demolition permit shall not be issued by any city ... as to any building or other structure except upon receipt from the permit applicant of a copy of each written asbestos notification regarding the building that has been required to be submitted to the United States Environmental Protection Agency or to a designated state agency, or both, pursuant to Part 61 of Title 40 of the Code of Federal Regulations, or the successor to that part. The permit may be issued without the applicant submitting a copy of the written notification if the applicant declares that the notification is not applicable to the scheduled demolition project.” .................................................................................. As applicant for a demolition permit in the City of Carlsbad, I certify that; I have read the excerpt from Section 19827.5 of the Health and Safety Code provided above; the information I have provided on this form is true and correct; and I further certify the following: ( ) Ontheattached pages are copies of all written asbestos notifications regarding the above referenced building that are required to be submitted to the United States Environmental Protection’Agency or to Part 61 of Title 40 of the Code of Federal Regulations, or successor to that part. ( ) I declare that the written asbestos notification is not applicable to the scheduled demolition project. Applicant’ s Signature Date i:\word\forms\building\demolition permit requirements.doc 1635 Faraday Avenue - Carlsbad, CA 92008-731 4 (760) 602-2700 FAX (760) 602-8560 REV August 9,2000 @