HomeMy WebLinkAbout1860 BIENVENIDA CIR; ; CB961893; PermitB'UILDING PERMIT Permit No: C8961893
10/09/96 11:21 i Project No: A9602700
Page 1 of 1 Development No:
JOb Address: 1860 BIENVENIDA CR Suite:
Permit Type: GUNITE POOLS AND SPAS 0264 10/03/?6 0001 01 02
Valuation: 11,865 Construction Type: NEW Occupancy Group: Reference#: Status: ISSUED
Description: 420 SF POOL & SPA-GUNITE Applied: 10/02/96
Apr/Issue: 10/09/96
Parcel No: 207-250-48-00 Lot#: C-mT 176 00
Entered By: RMA
Appl/Ownr : CALIFORNIA POOLS 619 744-8868
1635 S RANCHO SANTA FE
SAN PlARCOS CA 92069
*** Fees Required *** ked b Credits ***
Adjustments; .00
........................ .....................
Fees I
Total Fees! 88.00
176.00
Fee description Ext fee Data
Building Permit 135.00
Plan Check 88.00
Strong Motion Fee 1.00 Enter "Y" for Elec 20.00 Y
Enter "Y" for Plum 20.00 Y * BUILDING TOTAL 264.00
k
1 '<
CCTYOFCARLSBAD 2075 Las pahnas Dr., CMdmd, CA 9XW (619) 438-1161
PERMIT APPLICATION
City of Carlsbad Building Department 2075 Las Palms Dr., Carlsbad, U 92009 (619) 438-1161
From List 1 (see back) give code of Permit-Type:
PLAN CHECK NO.
.........................................................
I, r I; ... -. For Residential Proiects Only: From List 2 (see back) give
' f :'. .- . .: ._
Code of Structure-Type:
Net LoWCain of Dwelling Units
2 PRQJECTINFoRMAnON FOR OFFICE USE ONLY
Address 061 &J@,J, cLp Building or Suite No.
Nearest Cross Street
Unit No. Phase No.
0 2 Energy Calcs
DESCRIPTION OF WOM# # 1
0 2 Structural Calcs 0 2 Soils Report 0 1 Addressed Envelope --
2- e c
STATE LIC. # CITY BUSINESS LIC. #
-E (last name tirst)
CITY STATE ZIP CODE DAY TELEPHONE STATE LIC. #
Workers' Compensation Declaration: I hereby attirm that 1 have a certificate of consent to selt-insure issued by the Director ot Industnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCECOMPANY y+m &d n the pertormance ot the work tor which this permit is issued, I shall not employ any person in any manner Compensation Laws of California. /a -2--9/
Owner-Builder Ueclarauon: 1 hereby attirm that I am exempt trom the mntractors Llcense Law tor the tollowing reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
0
0 Business and Professions Code for this reason:
SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
IF ANYOF THE ANSWERS AREYES, AmAL CERTEICATJiOF OCCWANCY MAY NOT BE I$WED AFIERJULY 1,1989 UNLESS THE APPLICANT HAS MIT OR Is MElTING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR WLLUTION CONTROL DISIRIfX.
~ i iw e.
0 YES 0 NO
17 YES 0 NO
OYES 0 NO
W# LENDER'S ADDRESS r -/ LENDER'S NAME
1 certily that 1 have read the application and state that the above information is correct. 1 agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THEClTYOFCARISBAD AGAINSALLLIABILlllES, JUDGMENTS, a)6Is AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAIN= SAID ClTY IN CONSMZUEN(IE OF THE GRANTING OF THIS PERMIT.
OSHAr An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or ab mmenced for a period of 180 days (Section 303(d) Uniform Buil
: Applicant PINK: Finance
APPLICANTS SIGNATURE DATE: pw?i
i3 ___ -
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT# CB961893 FOR 06/09/97 INSPECTOR AREA DC DESCRIPTION: 420 SF POOL & SPA-GUNITE PLANCK# CB961893
TYPE: POOL CONSTR. TYPE NEW
APPLICANT: CALIFORNIA POOLS PHONE: 619 744-8868
OCC GRP
JOB ADDRESS: 1860 BIENVENIDA CR STE : LOT:
CONTRACTOR : PHONE : OWNER: PHONE : --h REMARKS: R/MARK/720-1550
SPECIAL INSTRUCT: INSPECTOR I/
TOTAL TIME:
CD LVL DESCRIPTION ACT $OMMENTS
55 SW Fence/Pre-Plaster - -- - -- - --
***** INSPECTION HISTORY *****
DATE 060597
012297
012297
012297
012297
112696
112696
102296
DESCRIPTION
Fence/Pre-Plaster Gas/Test/Repairs
Electric/Conduit/Wiring
Gas/Test/Repairs
Electric/Conduit/Wiring
Gas/Test/Repairs
Underground/Conduit-Wiring
Excav/Steel/Bonding/Fence
ACT INSP COMMENTS
CO DC
AP DC
AP DC AP DC
AP DC
CO PK SEE NOTICE CO PK AP DC
-
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT# CB961893 FOR 11/26/96 INSPECTOR AREA DC
DESCRIPTION: 420 SF POOL & SPA-GUNITE PLANCK# CB961893
TYPE: POOL CONSTR. TYPE NEW
JOB ADDRESS: 1860 BIENVENIDA CR STE: LOT:
APPLICANT: CALIFORNIA POOLS PHONE: 619 744-8868
CONTRACTOR: PHONE :
OCC GRP
OWNER: PHONE : n
REMARKS : MW/MARK/4 3 8-8 42 4
SPECIAL INSTRUCT:
TOTAL TIME:
--RELATED PERMITS-- PERMIT# TYPE
RW960187
INSPECTOR
CD LVL DESCRIPTION ACT COMMENTS
23 PL Gas/Test/Repairs
31 EL Underground/Conduit-Wiring
***** INSPECTION HISTORY *****
DATE DESCRIPTION ACT INSP COMMENTS
102296 Excav/Steel/Bonding/Fence AP DC
NOTICE , . -**
CITY OF CARLSBAD 438-3550
BUILDING DEPARTMENT 2075 LAS PALMAS DRIVE
DATE /jWJ6 TIME 9: 27"
FOR INSPECTION CALL 438-3101. RE-INSPECTION FEE DUE? c] YES
BUILDING PLANCHECK CHECKLIST
POOLS
BUILDING PLANCHECK NUMBER: CB b 18 93
BUILDING ADDRESS: /8b D ‘ei&cLc
PROJECT DESCRIPTION: Pool
ASSESSOR’S PARCEL NUMBER: d 0 7 2 s 0 - @
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans, information
andlor specifications provided in your submittal;
therefore, any changes to these items after this date,
including field modifications, must be reviewed by this
office to insure continued conformance with applicable codes. Please review carefully all comments attached,
as failure to comply with instructions in this report can result in suspension of permit to build,
ATTACHMENTS
0 Grading Permit Application
0 Grading Permit Checklist
0 Right-of-way Permit Application
0 Right-of-way Permit Submittal
Checklist and Information Sheet
DENIAL
Please see the attached report of deficiencies
marked with 0. Make necessary corrections to
plans or specifications for compliance with
applicable codes and standards. Submit corrected
plans and/or specifications to this office for review.
By: Date:
By: Date:
By: Date:
ENGINEERING DEPT. CONTACT PERSON
NAME: MICHELE MASTERSON
City of Carlsbad
ADDRESS: 2075 Las Palmas Drive
Carlsbad, CA 92009
PHONE: (619) 438-1161, ext. 4315
G:UIBRARVIENGiWORDSlWod~np~W~CHK14 FamMU.doc Rw. WWW
2075 Las Palmas Dr. - Carlsbad, CA 92009-1 576 - (61 9) 438-11 61 FAX (61 9) 438-0894
BUILDING PLANCHECK CHECKLIST - POOLS
ED’
ci
0
CI
CI
0
0
CI
SITE PLAN
3RW
0 1. Provide a fully dimensioned site plan drawn to scale. Show:
w A. NorthArrow /
B. Existing & Proposed Structures L, D. Easements-w-
C. Property Lines
CI 2. Show on site plan:
A. DrainagePatterns D. Indicate what will happen with ’
B. Existing & Proposed Slopes soil excavated from pool area
C. Existing Topography / E. Retaining Walls %‘A- &
(location and height) &..wdk
6M YL
Note: If excavated soil is not to be removed from property but regraded on
site, show proposed elevations and slopes.
If any portion of retaining walls are over 4’ in height, a separate permit is required.
Retaining Wall Permit CB Applied for Approved
0 3. Include on title sheet:
A. Site Address
B. Assessor’s Parcel Number
C. Legal Description
D. Grading Quantities Cut Fill ImporVExport
CI 4. Project does not comply with the following Engineering Conditions of approval
for Project No.
Conditions were complied with by: Date:
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for grading permit are found in Section
11.06.030 of the Municipal code.
0 5a. Inadequate information available on Site Plan to make a determination on
grading requirements. Include accurate grading quantities (cut, fill, import,
export).
0 5b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached.
Note: The Grading Permit must be issued and rough grading approval
obtained prior to issuance of a Building Permit
Page 1 of 2
RW. smroe
qST/ 2NW 3RD'
CI CI 0 5c. A Grading Permit has been applied for:
PE2 DWG
Grading Inspector sign off by: Date:
CI D 0 5d. No Grading Permit required.
MISCELLANEOUS PERMITS
0 6. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way and/or
private work adjacent tot he public Right-of-way.
A separate Right-of-way issued by the Engineering Department is required
for the following:
Please complete attached Right-of-way application form and return to the
Engineering Department together with the requirements on the attached Right-
of-Way checklist, at the time of resubmittal.
Right-of-way Permit and Pool Building Permit will be issued simultaneously.
0 7. Remarks
Page 2 of 2
. ._ .