HomeMy WebLinkAbout1865 High Ridge Ave; ; CBR2018-1433; Permit(city of
Carlsbad
Print Date: 01/14/2019
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
1865 High Ridge Ave
BLDG-Residential
2073851600
$26,882.78
Residential Permit
Work Class: Alteration
Lot#:
Reference #:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Status:
Applied:
Issued:
Permit
Fina1ed:
Inspector:
Final
Inspection:
Permit No: CBR2018-1433
Closed -Finaled
06/14/2018
07/16/2018
CRenf
1/14/2019 9:15:34AM
Description: HALL: 578 SF REMODEL UPDATE KITCHEN, CONVERT POWDER TO FULL BATH, DEN TO BEDROOM AND DINING TO STUDY
Applicant: Owner:
MATTHEW BALDWIN
2604 El Camino Real, 8-250
Carlsbad, CA 92010
760-473-2799
COOWNER STEVE GRIER AND DAVID COLLEY
1865 High Ridge Ave
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Carlsbad, CA 92008-3760
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $548.45 Total Payments To Date: $548.45 Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. lf you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
$0,00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
$258.80
$181.16
$41.00
$62.00
$2.00
$3.49
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING 0 ENGINEERING □BUILDING □FIRE 0 HEALTH 0 HAZMAT/APCD
, ( City of Building Permit Application Plan Check No.Q.0R ::1() \ <;< --1 L\ ~ "\
1635 Faraday Ave., Carlsbad, CA 92008 Est. Value 1t~ > ln -xR~ , }'(
Ph: 760-602-2719 Fax: 760-602-8558 Carlsbad Plan Ck. Deposit ' -' email: building@carlsbadca.gov
www.carlsbadca.gov Date (n/lL/ / / 'X' I
JOB ADDRESS SUITE#/SPACE#/UNIT#
IAPN 207 1865 HIGH RIDGE AVE -385 -16 -00
CT /PROJECl # I LOT# I PHASE# I # OF UNITS I# BEDR;MS # BATHROOMS I TENANT BUSINESS NAME r ONSTR. TYPE I occ. GROUP
16 3 V-B NR
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
PARTIAL INTERIOR REMODEL OF EXISTING RESIDENCE. SCOPE INCLUDES· UPDATE EXISTING KITCHEN, CONVERT
EXISTING POWDER BATH TO FULL BATH, CHANGE STUDY/DEN TO BEDROOM, CHANGE DINING ROOM TO OFFICE/STUDY.
5·78~F of I tvi-£ (l. le. IL fl.£ µf o O E_L
EXISTING USE I PROPOSED USE ~RAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS I
SINGLE FAMILY (SFR) (E) TO REMAIN )414 N/A N/A YESO No□ YES □No □ YES□No[Z] I
APPLICANT NAME MATTHEW BALDWIN PROPERTY OWNER NAME STEVE GRIER AND DAVID COLLEY Drfflaru i"n.n•-_.
ADDRESS ADDRESS 2604b EL CAMINO REAL, SUITE 250 -1865 HIGH RIDGE AVE
CITY STATE ZIP CITY STATE ZIP CARLSBAD CA 92008 CARLSBAD CA 92008
PHONE I FAX PHONE I FAX 760-473-2799 N/A 760.573.4305
EMAIL EMAIL
mbaldwin@peoplescaledesign.com griercolley@gmail.com
DESIGN PROFESSIONAL PAUL LONGTON OF STUDIO 4 CONTRACTOR BUS. NAME
.__
ADDRESS ADDRESS 2909 MESA DRIVE
CITY STATE ZIP CITY STATE ZIP
f---~ OCEANSIDE CA 92054
I FAX PHONE I FAX PHONE
760-458-0987 .__
EMAIL EMAIL
pjlongton(@,gmail.com
I STATE LICC-18757 STATE LIC.# I CLASS I CITY BUS. LIC.# CALIFORNIA· 2/28/19
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter. improve. demolish or repair any structure, prior to its issuance. also requires the applicant for such per_mit to file a signed st\ltement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, comme_nding with Section 1qoo of Division 3 of the Business and Professions Code) or !hat he 1s exempt therefrom, and the basis for the alleged exemption. Any v1olat1on of Section 7031.5 by any applicant for a permit subJects the apphcant to a civil penalty of not more than five hundred dollars ($500)).
Wor1ms' Compensation Declaration: I hereby affirm under penally of perjury one of the following declarations:
D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which lhis permit is issued. D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of lhe work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. __ Policy No ____________ _ Expiration Dale ________ _
This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to lhe Workers' Compensalion Laws of
California WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
2$ CONTRACTOR SIGNATURE QAGENT DATE
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
□ I, as owner of the property or my employees with wages as lheir sole compensation, will do the work and the slructure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon. and who does such work himself or lhrough his own employees, provided that such improvements are nol intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving lhat he did not build or improve for the purpose of sale)
I. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contraclor·s License Law does not apply to an owner of
property who builds or improves thereon. and conlracts for such projects wilh contractor(s) licensed pursuanl to the Conlraclor's License Law).
I am exempl under Section ____ Business and Professions Code for this reason:
1 I personally plan lo provide the major labor and materials for construction of the proposed property improvemenl. 0 Yes 0 No
2 I (have/ have not) signed an application for a building permit for the proposed work.
3. I h ve conlracted wilh the following person (firm) lo provide the proposed construclion (include narre address / phone / contractors' license number):
4 I e work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address I phone/ conlractors' license number):
11 (hir d lhe following persons lo provide the work indicated (include narre / address /phone/ type of work):
□AGENT DATE 0/ I ls> ( 8>
Is the applicant or future building occupant required lo submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? 0 Yes O No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes O No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes O No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT.
Lender's Address
I certify that! have read the application and state that the above information Is correct and that the Information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby autholize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INOEMNIFY ANO KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA pl!ITTltt is required for excavations <Ner 5'0' deep and demolition or construction of structures over 3 stories in height
EXPIRATION: Every permtt issued by the Building Official under the provisions of this Code shall expire by limitation and become nuU and void if the building or work authorized by such permit is not commenced within
180 days from the date of such pennit or if the building uthorized by such permtt is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
_IS APPLICANT'S SIGNATURE DATE
Permit Type:
Work Class:
Status:
Scheduled
Date
January 14, 2019
PERMIT INSPECTION HISTORY REPORT (CBR2018-1433)
BLDG-Residential Application Date: 06/14/2018 Owner:
Alteration Issue Date: 07/16/2018 Subdivision:
Closed -Finaled Expiration Date: 07/10/2019 Address:
IVR Number: 11972
Actual
Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLOG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLOG-Electrical Final
COMMENTS
COOWNER STEVE GRIER AND
DAVID COLLEY
CARLSBAD TCT#82-05 A
1865 High Ridge Ave
Carlsbad, CA 92008-3760
Relnspectlon
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Page 2 of 2
PERMIT INSPECTION HISTORY REPORT (CBR2018-1433)
Permit Type: BLDG-Residential Application Date: 06/14/2018 Owner: COO\/1/NER STEVE GRIER AND
DAVID COLLEY
Work Class: Alteration Issue Date: 07/16/2018 Subdivision: CARLSBAD TCT#82-05 A
Status: Closed -Finaled Expiration Date: 07/10/2019 Address: 1865 High Ridge Ave
Carlsbad, CA 92008-3760
IVR Number: 11972
Scheduled Actual Inspection Type Date Start Date Inspection No. Inspection Status Primary Inspector Relnspection Complete
07/25/2018 07/25/2018 BLDG-13 Shear 064866-2018 Failed Chris Renfro Relnspectlon Complete
Panels/HD (Ok to
wrap)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Need special inspector to verify epoxy hold No
downs.
07/30/2018 07/30/2018 BLDG-84 Rough 065338-2018 Passed Chris Renfro Complete
Combo{14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
{Decks)
BLOG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
08/08/2018 08/08/2018 BLDG-17 Interior 066344-2018 Passed Chris Renfro Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Yes
09/21/2018 09/21/2018 BLOG-27 Shower 070707-2018 Passed Chris Renfro Complete
Pan/Tubs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10116/2018 10/16/2018 BLDG-18 Exterior 073278-2018 Passed Chris Renfro Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Interior shower wall waterproof Yes
01/11/2019 01/1112019 BLDG-Final 081106-2019 Partial Pass Chris Renfro Reinspection Incomplete
Inspection
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Not ready. Shower glass enclosure needs No
to be installed.
BLOG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
01114/2019 01/14/2019 BLDG-Final 081215-2019 Passed Chris Renfro Complete
Inspection
January 14, 2019 Page 1 of 2
GeoTek, Inc. Field ~bservation Report
CLIENT:
PROJECT:
LOCATION:
CONTRACTOR:
WORK IN PROGRESS ( ) GRADING
( ) STREET: SG __ B __ AC __
( ) SIDEWALK: SG __ B __
EQUIPMENT:
COMMENTS L DISCUSSION
V 4 flol~s
.[eo-c,.J~,q. -'
a> I I b I 2 .. o / j
Q BIi
J-/o le) 0 ~ C) u,J""
r::)5·\". ()Sr-,,. I ~Po ';<.-..J Olnr ,.. J c--""'-ve r --~·-"-,.,.Q ... ,.{ ... \... " .
JEST RESULTS lh--v,.,J. '\N-. r'>n .,, L C. \. \JV e J Co--w-.. ~ C
TEST LOCATION ELEV/ MOISTURE DRY
NO. DEPTH CONTENT DENSITY
-----l1<"Z1":+
~
' ,,., ~ ~cl 51,
/
~
/
BY: /\)A? A{) Th'{'t--& )
PRINT NAME
COPIES TO: OFFICE CLIENT/REP AGENCY
(WHITE)___ (YELLOW) __ _ (PINK) __ _
C, ,,t \-::,' Dv k, I:
I C'C E <.. -a(-<. l
1''-f
SOILI TEST
TYPE MAXD TYPE REL COMP
'--
\
/ ,,
DATE: 07/09/18
JURISDICTION: Carlsbad
PLAN CHECK#.: CBR2018-1433
PROJECT ADDRESS: 1865 High Ridge Avenue
PROJECT NAME: Remodel for the Grier
□ APPLICANT
□ JURIS
SET: II
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~
□
□
Paul Longton
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did ad73ise the pplicant that the plan check has been completed.
Person contacted: P Longton Telephone#: 760 458 0987
Date contacted: (by:~ ) Email: pjlongton@gmail.com
Mail Telephone Fax In Person
REMARKS:
By: Javier Snider
EsGil
Enclosures:
07/02/18
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 06/26/18
JURISDICTION: Carlsbad
PLAN CHECK#.: CBR2018-1433
✓• EsG1I
SET: I
PROJECT ADDRESS: 1865 High Ridge Avenue
PROJECT NAME: Remodel for the Grier
_;}APPLICANT r JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
IZJ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
IZJ The applicant's copy of the check list has been sent to:
Paul Longton
D EsGil staff did not advise the applicant that the plan check has been completed.
IZJ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Paul Longton Telephone#: 760 458 0987
Date contacted: l.{zs/1o(byHf...P) Email: pjlonton@gmail.com
,eMail Telephon Fax In Person j
RKS:
By: Javier Snider
EsGil
Enclosures:
06/18/18
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBR2018-1433
06/26/18
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2018-1433 JURISDICTION: Carlsbad
PROJECT ADDRESS: 1865 High Ridge Avenue
FLOOR AREA: Total=3505sf
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 06/26/18
FOREWORD (PLEASE READ):
STORIES: 2
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 06/18/18
PLAN REVIEWER: Javier Snider
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CBR2018-1433
06/26/18
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Javier Snider
PLAN CHECK#.: CBR2018-1433
DATE: 06/26/18
BUILDING ADDRESS: 1865 High Ridge Avenue
BUILDING OCCUPANCY: R-3
BUILDING AREA Valuation Reg.
PORTION ( Sq. Ft.) Multiplier Mod.
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
----· --···
1997 UBC Building Permit Fee •i
1997 UBC Plan Check Fee
Type of Review: 0 Complete Review
□ Other
VALUE
□ Structural Only
□ Repetitive Fee --~ Repeats .1 -~_j
0 Hourly
EsGII Fee
1------11 Hr. @ *
Comments: In addition to the above fee, an additional fee of$
$ /hr.) for the CalGreen review.
($)
26,883
26,883
$147.SOJ
is due ( hour@
Sheet of
Carlsbad CBR2018-1433
06/26/18
PLANS
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in
one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering
and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire Departments.
1. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
2. Plans deviating from conventional wood frame construction shall have the
structural portions signed and sealed by the California state licensed engineer or
architect responsible for their preparation, along with structural calculations.
(California Business and Professions Code).
FIRE PROTECTION
3. Show locations of permanently wired smoke alarms with battery backup, per
Section R314:
a) Inside each bedroom.
b) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
c) On each story, including basements.
d) Such smoke alarm locations shall comply with the following:
i) They shall be not less than 3' from the door opening of a bathroom.
ii) They shall be at least 20' from a cooking appliance.
iii) They shall be at least 3' from supply registers of heating/cooling
systems.
iv) They shall be at least 3' from the tip of the blade of a ceiling-
mounted fan.
• NOTE: When more than one smoke alarm is required to be installed, the
alarm devices shall be interconnected in such a manner that the actuation of
one alarm will activate all of the alarms in the unit.
Carlsbad CBR2018-1433
06/26/18
GENERAL RESIDENTIAL REQUIREMENTS
4. Bathrooms and powder rooms must be mechanically ventilated (an openable
window won't suffice). Section R303.3.1.
ELECTRICAL
5. Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
6. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
b) Weather resistant type for receptacles installed in damp or wet locations
(outside).
c) Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.12(A): Kitchens, laundry areas, family, living,
bedrooms, dining, halls, etc.
d) GFCI protected outlets for locations described in NEC 210.B(A): Laundry
areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors,
within 6' of a sink, etc.
PLUMBING
7. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
MISCELLANEOUS
8. Please show that there is no point in the new bedroom is 6' from an outlet.
9. Special inspection is required for epoxy and retro fitted hold downs please note
on plans.
10. Show foundation to verify shear wall adequacy.
11. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Carlsbad CBR2018-1433
06/26/18
12. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □