Loading...
HomeMy WebLinkAbout187 Cherry Ave; ; CB161974; PermitPrint Date: 01/08/2020 Job Address: PermitType: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 187 Cherry Av BLDG-Residential 2042320100 $ 478,796.00 1 Residential Permit Work Class: Lot#: Reference#: Construction Type Bathrooms: Orig. Plan Check#: Plan Check#: Condo 3 DEV15033 PC160031 Project Title: CHERRYFIELD BEACH HOMES Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: {city of Carlsbad Permit No: CB161974 Closed -Expired 05/19/2016 10/11/2017 TFraz Description: CHERRYFIELD TOWNHOMES:(UNIT 3) 3,372 SF LIV// 421 SF GAR// 574 SF DECKS FEE BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) Owner: MATTHEW CASTRIOTTA MATTHEW CASTRIOTTA 951-440-0441 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEEs'-outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL WATER METER FEE 1" Displacement Total Fees: $ 20,231.57 Total Payments To Date : $ 20,231.57 Co-Applicant: PROPHET SOLUTIONS INC 5845 Avenida Encinas, 138 Carlsbad, CA 92008-4432 760-999-2146 Balance Due: AMOUNT $1,971.45 $880.02 $66.00 $166.00 $92.00 $182.00 $16,757.86 $20.00 $62.24 $34.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees /exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY REPORT (CB161974) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: Work Class: Condo Issue Date: 10/11/2017 Subdivision: Status: Closed -Expired Expiration Date: 11/04/2019 Address: IVR Number: 714643 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 03/14/2019 03/14/2019 BLDG-16 Insulation 086151-2019 Checklist Item BLDG-Building Deficiency 04/01/2019 04/01/2019 BLDG-17 Interior 087574-2019 Lath/Drywall Checklist Item BLDG-Building Deficiency 05/08/2019 05/08/2019 BLDG-84 Rough 091169-2019 Combo(14,24,34,44) COMMENTS Passed Tim Frazee COMMENTS 6" rigid foam over vaulted area Wall and Ceiling insulation OK 3/14/19 Passed Tim Frazee COMMENTS Passed Tim Frazee Checklist Item COMMENTS BLDG-14 Steel stud soffit framing OK Frame-Steel-Bolting-Welding (Decks) MATTHEW CASTRIOTTA 187 Cherry Av Carlsbad, CA 92008 Reinspection Complete Passed Yes Yes Yes Yes Yes Complete Passed Yes Complete Passed Yes Complete Passed Yes January 08, 2020 Page 4 ol 4 PERMIT INSPECTION HISTORY REPORT (CB161974) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: MATTHEW CASTRIOTTA Work Class: Condo Issue Date: 10/11/2017 Subdivision: Status: Closed -Expired Expiration Date: 11/04/2019 Address: 187 Cherry Av IVR Number: 714643 Carlsbad, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 10/09/2018 10/09/2018 BLDG-15 072213-2018 Partial Pass Chris Renfro Reinspection Incomplete Rool/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Flat roof deck Nailing. OK to build cricket. Yes Need height certification before roof inspection. 11/13/2018 11/13/2018 BLDG-15 075872-2018 Partial Pass Michael Collins Reinspection Incomplete Rool/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Flat roof deck Nailing. OK to build cricket. Yes Need height certification before roof inspection. BLDG-Building Deficiency Upper roof except stair tower Yes 12/11/2018 12/11/2018 BLDG-23 078456-2018 Partial Pass Paul Burnette Reinspection Incomplete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/13/2018 12/13/2018 BLDG-15 078761-2018 Partial Pass Michael Collins Reinspection Incomplete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency OSB over rigid foam Yes BLDG-Building Deficiency Flat roof deck Nailing. OK to build cricket. Yes Need height certification before roof inspection. BLDG-Building Deficiency Upper roof except stair tower Yes BLDG-16 Insulation 078762-2018 Partial Pass Michael Collins Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency 6" rigid foam over vaulted area Yes 01/04/2019 01/04/2019 BLDG-13 Shear 080485-2019 Passed Tim Frazee Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/12/2019 02/12/2019 BLDG-16 lnsulatlon 083657-2019 Partial Pass Paul Burnette Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency 6" rigid foam over vaulted area Yes 03/04/2019 03/04/2019 BLDG-84 Rough 084969-2019 Passed Tim Frazee Complete Combo(14,24,34,44) January 08, 2020 Page 3 of4 PERMIT INSPECTION HISTORY REPORT (CB161974) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: Work Class: Condo Issue Date: 10/11/2017 Subdivision: Status: Closed -Expired Expiration Date: 11/04/2019 Address: IVR Number: 714643 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 04/12/2018 04/12/2018 BLDG-21 Underground/Underf loor Plumbing 054762-2018 Checklist Item BLDG-Building Deficiency 04/17/2018 04/17/2018 BLDG-11 Foundation/Ftg/Pier s (Rebar) 055223-2018 Checklist Item BLDG-Building Deficiency BLDG-24 Rough/Topout 055224-2018 Checklist Item BLDG-Building Deficiency 04/30/2018 04/30/2018 BLDG-11 Foundation/Ftg/Pier s (Rebar) 056435-2018 Checklist Item BLDG-Building Deficiency 05/10/2018 05/10/2018 BLDG-11 Foundation/Ftg/Pier s (Rebar) 057634-2018 Checklist Item BLDG-Building Deficiency 09/12/2018 09/12/2018 BLDG-14 069769-2018 Frame/Steel/Bolting/ Welding (Decks) Checklist Item BLDG-Building Deficiency BLDG-24 Rough/Topout 069771-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency 09/18/2018 09/18/2018 BLDG-11 070338-2018 Foundation/Ftg/Pier s (Rebar) Checklist Item BLDG-Building Deficiency January 08, 2020 Passed Paul Burnette COMMENTS Partial Pass Michael Collins COMMENTS HSS column tie in, see card. Partial Pass Michael Collins COMMENTS Underground storm drain POC tie in. Partial Pass Paul Burnette COMMENTS HSS column tie in, see card. Partial Pass Paul Burnette COMMENTS HSS column tie in, see card. Failed COMMENTS Not ready Partial Pass COMMENTS Michael Collins Michael Collins Underground storm drain POC tie in. Underground waste to POC for laundry sink Passed Paul Burnette COMMENTS HSS column tie in, see card. MATTHEW CASTRIOTTA 187 Cherry Av Carlsbad, CA 92008 Re inspection Complete Complete Passed Yes Reinspection Incomplete Passed Yes Reinspection Incomplete Passed Yes Reinspection Incomplete Passed Yes Reinspection Incomplete Passed Yes Reinspection Complete Passed No Re inspection Incomplete Passed Yes Yes Complete Passed Yes Page 2 of 4 PERMIT INSPECTION HISTORY REPORT (CB161974) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: MATTHEW CASTRIOTTA Work Class: Condo Issue Date: 10/11/2017 Subdivision: Status: Closed -Expired Expiration Date: 11/04/2019 Address: 187 Cherry Av Carlsbad, CA 92008 IVR Number: 714643 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date -11/21/2017 11/21/2017 BLDG-11 041159-2017 Passed Michael Collins Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Lower CMLI footing/steel Yes 12/11/2017 12/11/2017 BLDG-11 042979-2017 Passed Chris Renfro Complete Foundatlon/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-66 Grout 042978-2017 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/04/2018 01/04/2018 BLDG-66 Grout 045012-2018 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/26/2018 01/26/2018 BLDG-12 Steel/Bond 046975-2018 Partial Pass Andy Krogh Reinspection Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency 8" poured in place wall at shoring/ stairwell Yes 03/14/2018 03/14/2018 BLDG-21 061718-2018 Failed Paul Burnette Reinspection Complete Underground/Underf Joor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-22 051719-2018 Failed Paul Burnette Re inspection Complete Sewer/Water Service Checklist Item COMMENTS Passed BLDG-Building Deficiency No 03/22/2018 03/22/2018 BLDG-21 052534-2018 Passed Michael Collins Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste to POC with 6 inch sewer BF device. Yes BLDG-22 052535-2018 Passed Michael Collins Complete Sewer/Water Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste to POC Yes January 08, 2020 Page 1 of4 Construction Testing & Engineering, Inc. Inspection I Testing I Geotechnlcal I Environmental & Construction Engineenng I Civil Englneenng I Surveying DAILY FIELD REPORT Client: Prophet Solutions Job Number: 10-13893T Job: Name: Cher~ Field Beach Homes Day( 5): Wednesday Job Location: 187, 191, 195, Cherrv Ave, CaMsbad, CA92009 Date(s): 12-19-18 Gen. Contractor: Sub Contractor(s): General Description: 195, Cherry Ave unit #1, permit number: CB161977 191, Cherry Street unit #2, permit number: CB161976 187, Cherry Streetunit#3, permit number: CB161974 Engineer: La Costa Engineering Shearwall Inspection Inspected the Shear walls for buildings 1, 2 and 3 per sheets S2, S3, S4, S5 and the shear wall schedule on sheet SN3. Verified materials. nailing, hold-down, foundation connection and shear transfer between floors/roof, Installation is compliant with the approved plans except for the items listed on the areas of additional concern. •Re-Inspection is required to check areas of concern. * PLEASE NOTE ANY RE-INSPECTION/TESTING COMMENTS/ AREAS OF ADDITIONAL CONCERN Unit #1, level 2, shear transfer top plate to rim, A35 6"0/c on grid line D between grid line 3 through 3.5. Unit #2, level 2, shear transfer top plate to rim, A35 6"0/c on grid line F between grid line 4 through 4.2. Unit #2, level 2, shear transfer 3X bottom plate to joist below at grid line 6. Unit #3, deck level, shear transfer 3X bottom plate to rim below at grid line E.8/6.6 . _,, ./ BY: Bill Atwood ~ ~✓ ·-DATE: 12-19-18 CERTIFICATION NO: 5012754 ,t;,,,-7 -.;::,,,, , -. 1441 MONTIEL ROAD ESCONDIDO, CA92026 (760) 746-4955 FAX (760) 746-9806 b~A,lnc. land planning, civil engineering, surveying November 29, 2017 w.o. 1001-1113-600 Mr. Paul Burnette Senior Building Inspector CITY OF CARLSBAD Community and Economic Development Building Division 1635 Faraday Avenue Carlsbad, CA 92008 ROD BRADLEY, Urban Planner RONALD L. HOLLOWAY, Civil Engineer RE: BUILDING LAYOUT AND SET BACK VERIFICATION OF UNITS 1, 2 AND 3, CHERRY-FIELD BEACH HOMES, MS 15-08 Dear Mr. Burnette: This letter is to attest that BHA, Inc. has staked the location for the building construction on the above-mentioned units. In addition we have checked the layout of the proposed building and found the horizontal and vertical location to conform to the grading plans prepared by our office. If you have any questions regarding this matter, please contact our office. Sincerely, I Vice President PLS5941 AAM: cc: Randy Smith -Prophet Solutions • 5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 ° (760) 931-8700 o FAX (760) 931-7780 . Construction Testing & Engineering, Inc. Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying INSPECTION REPORT PAGE -L OF _j_. CTE JOB NO./cJ-/3fJ) _3 REPORT NO. PROJECT NAME ---=---!:..S&.d!L/:-J~~'d.....+~=<....L&.cH.:)-C $. INSPECTION ADDRESS ~B:.../..-t..LCL--4-L..,,,{-...!..._~=~-}£-...LL~"--□ CONCRETE 0 REINF. STEEL _L.L..!~~.LLl~.f----:-~.,,....L,,u.!...ie<Ll=-t":~c.J§-□ MASONRY ARCHITECT ENGINEER CONTRACTOR /4 CAS £t /✓f;f/lzb/!l;,_5 □ P.T. CONCRETE fr();:,.Ad-5icJtahn.s /11c, □ FIELD WELDING I MATERIAL IDENTIFICATION CONC. MIX NO. & lb/in2 GROUT MIX NO. & lb/in2 MORT AR TYPE & lb/in2 REINF. STEEL GR./SIZE ,1~t)~ /Ht;, I) I STRUCTURAL STEEL OTHER □ SHOP WELDING HIGH-STRENGTH BOLT ____ _ INSPECTION DATE PLAN FILE/OTHER BLDG. PERMIT/OTHER 4 0 BATCH PLANT MASONRY BLOCK 0 EXP. ANCHOR □ OTHER MATERIAL SAMPLING OTHER 0 CONCRETE 0 MORTAR 0 GROUT 0 FIREPROOFING O MASONRY BLOCK □ REINFORCING STEEL 0 STRUCTURALSTEEL ·:~~ .. 0 SOL TS O OTHER -~;-·• INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES. Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the appr~'\led plans and specifications. PRINTED NAME #f H ,,, y /z.~~~ I CERTIFICATION NO. /a-<"g5"~J-:)y .Si,9Jsz 1441 Montiel Road, Suite 115 I Escondido, CA92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net bHA, Inc. land planning, civil engineering, surveying October 9, 2018 w.o. 1001-1113-100 Mr. Paul Burnette Building Inspector CI1Y OF CARLSBAD Community and Economic Development Building Division 1635 Faraday Avenue Carlsbad, CA 92008 o~~ f;, G 0~ ~~() ROD BRADLEY, Urban Planner RONALD L. HOLLOWAY, Civ/1 Engineer NOISI/\IG 8NiOlinS BL0l 6 l'.lO City "f "'A'"'<;had peqstJi~ JO A\!:l '-l •. ; Cily of Carlsbad . I ,J'ViS!C, J OCT 9 2018 BUILDING DIVISION RE: ROOF HEIGHT VERIFICATION OF UNITS 1 THRU 3, 187, 191 & 195 CHERRY AVENUE, CHERRY-FIELD BEACH HOMES, MS 15-08 Dear Mr. Burnette: This letter is to attest that BHA, Inc. has surveyed the roof height of the building for the above-mentioned project. The top of roof elevation for the center ridge line is shown on the building plans dated 01-04- 2018 as 91.0'. We have surveyed the elevation of the existing roof at the center ridge line as 90.94'. Th·e top of roof elevation for the flat roof is shown on the building plans dated 01-04-2018 as 85.0'. We have surveyed the elevation of the existing flat roof as 84.93'. If you have any questions regarding this matter, please contact our office. Sincerely, bHA, Inc. ·1l-. \ttTr'v'--(,WV\/ Ronald L. Holloway Senior Vice President RCE29271 RH:rh cc: Matthew Castriotta Randy Smith -Prophet Solutions K:\Land Projects 3\826-1113-600\survey\roof height-verificnlion-cberry.wpd 5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 o (760) 931-8700 o FAX (760) 931-7780 bHA,lnc. land planning, civil engineering, surveying October 9, 2018 w.o. 1001-1113-100 Mr. Paul Burnette Building Inspector CITY OF CARLSBAD Community and Economic Development Building Division 1635 Faraday Avenue Carlsbad, CA 92008 ROD BRADLEY, Urban Planner RONALD L. HOLLOWAY, Civil Engineer RE: ROOF HEIGHT VERIFICATION OF UNITS 1 THRU 3, 187, 191 & 195 CHERRY AVENUE, CHERRY-FIELD BEACH HOMES, MS 15-08 Dear Mr. Burnette: This letter is to attest that BHA, Inc. has surveyed the roof height of the building for the above-mentioned project. The top of roof elevation for the center ridge line is shown on the building plans dated 01-04- 2018 as 91.0'. We have surveyed the elevation of the existing roof at the center ridge line as 90.94'. The top of roof elevation for the flat roof is shown on the building plans dated 01-04-2018 as 85.0'. We have surveyed the elevation of the existing flat roof as 84.93'. If you have any questions regarding this matter, please contact our office. Sincerely, bl-IA, Inc. ·1l,~ \ ............... Ronald L. Holloway Senior Vice President RCE29271 RH:rh cc: Matthew Castriotta Randy Smith -Prophet Solutions K:\Land Projccls 3\826-1113-600\survey\roof height-verification-cherry.wpd 5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 " (760) 931-8700 ° FAX (760) 931-7780 bHA,lnc. land planning, civil engineering, surveying October 9, 2018 w.o. 1001-1113-100 Mr. Paul Burnette Building Inspector CITY OF CARLSBAD Community and Economic Development Building Division 1635 Faraday Avenue Carlsbad, CA 92008 ROD BRADLEY, Urban Planner RONALD L. HOLLOWAY, Civil Engineer RE: ROOF HEIGHT VERIFICATION OF UNITS 1 THRU 3, 187, 191 & 195 CHERRY AVENUE, CHERRY-FIELD BEACH HOMES, MS 15-08 Dear Mr. Burnette: This letter is to attest that BHA, Inc. has surveyed the roof height of the building for the above-mentioned project. The top of roof elevation for the center ridge line is shown on the building plans dated 01-04- 2018 as 91.0'. We have surveyed the elevation of the existing roof at the center ridge line as 90.94'. The top of roof elevation for the flat roof is shown on the building plans dated 01-04-2018 as 85.0'. We have surveyed the elevation of the existing flat roof as 84.93'. If you have any questions regarding this matter, please contact our office. Sincerely, bl-iA, Inc. ·1l"--\~~AlTA/ Ronald L. Hollowa~ -0 Senior Vice President RCE29271 RH:rh cc: Matthew Castriotta Randy Smith -Prophet Solutions K:\Land Projects 3\826-1113-600\survey\roof height-verification-cherry.wpd 5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 o (760) 931-8700 ° FAX (760) 931-7780