HomeMy WebLinkAbout1900 ASTON AVE; 120; CBC2019-0376; Permit4 (r, Lcity of Carlsbad Commercial Permit Print Date: 11/27/2019 Permit No: CBC2019-0376 Job Address: 1900 Aston Ave, 120 Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed - Finaled Parcel No: 2121202400 Lot if: Applied: 08/01/2019 Valuation: $181,807.59 Reference if: Issued: 08/28/2019 Occupancy Group: B Construction Type: V-B Permit Finaled: if Dwelling Units: Bathrooms: Inspector: MColI Bedrooms: Orig. Plan Check #: Final Plan Check M. Inspection: 11/27/2019 3:02:09PP Project Title: Description: M2 INGREDIENTS: 3,909 SF T.I. - OFFICE TO OFFICE (CREATE SUITE 120 FROM PART OF SUITE 100) Applicant: Owner: Contractor: KIMBERLY KRENEK P D G CARLSBAD 59 LIMITED KELCHLIN CONSTRUCTION INC 6520 Nancy Ridge Dr San Diego, CA 92121-2250 1900 Aston Ave 13100 Kirkham Way, Ste 201 858-558-5935 CARLSBAD, CA 92008 Poway, CA 92064-7128 858-513-3799 BUILDING PERMIT FEE ($2000+) $917.10 BUILDING PLAN CHECK FEE (BLDG) $641.97 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $89.00 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $55.00 PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL $86.00 5B1473 GREEN BUILDING STATE STANDARDS FEE $8.00 STRONG MOTION-COMMERCIAL $50.91 Total Fees: $1,847.98 Total Payments To Date: $1,847.98 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the' statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov ok (C ity of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B2 Plan Check 6w"an 9- 03 Est. Value PC Deposit Date ____________ Job Address 1900 Aston Ave. Suite: 12.0 APN: 212-120-24-00 Tenant Name: M2 Ingredients CT/Project #: Lot #: 59 Occupancy: B Construction Type: V-B_ Fire Sprinklers: yes / no Air Conditioning: yes / no BRIEF DESCRIPTION OF WORK: Tenant improvement to renovate existing office, change in Occupancy. Addition/New: New SF and Use, __New SF and Use, Deck SF, Patio Cover SF (not including flatwork) Tenant Improvement: 30O SF, SF, Existing Use ..,. Existing Use Proposed Use B. Proposed Use O Pool/Spa: •SF Additional Gas or Electrical Features? E3 Solar: KW, _Modules, Mounted, Tilt: Yes / No, RMA: Yes / No, Panel Upgrade: Yes / No Plumbing/Mechanical/Electrical Only: El Other: APPLICANT (PRIMARY) PROPERTY OWNER Name:Kimberly A. Krenek, AlA Name: P2) Ir cp./$23201 9, L Id Address: 6520 Nancy Ridge Drive Address: S_L.o-,€,.s _/ City: ScnDiego State: CA zip: 92121 City:-S4'State: cA Zip: Phone: 858-558-5935 Phone: (ci_19_2..5 -2 Email:kimberly@krenekdesign.com Email: ,.' DESIGN PROFESSIONAL Name: Kimberly A. Krenek, AlA Address: 6520 Nancy Ridge Drive City: San Diego State:CA Zip: 92121 Phone: 858-558-5935 Email: .kimber1y@krcnckdesigi.com Architect State License: C 26786 CONTRACTOR BUSINESS Name: rJ CJ-fl ic1 Address: ),ioo )44 LjC4*pr city tt&JP4 State: C3Zip: Phone:('5Yc- V7 Email:iT %-)L4VJ L)tJ State License) (a' (ZS Bus. License: _1I (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its Issuance, also requires the applicant for such permit to file a signed statement that he/she Is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he/she Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than live hundred dollars ($5001). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: BuildingccarIsbadca.gov B-2 Page 1 of 2 Rev. 08/18 (OPTION A): WORKERS'COMPENSATION DECLARATION: I heorby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-Insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. O I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued. My workers' compensation insurance carrier and policy number are: Insurance C pa / y Name: iXZij-t (0 rvfJf J Ji ) rj Policy No. cos L'J'3 O' Expiration Date: 12 -T' O Certificate of Exemption: I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, In addition the to e c o o pensation, damages as provided for In Section 3706 of the Labor Code, Interest and attorney's fees. I i CONTRACTOR SIGNATUAE., DAGENT DATE:3) 2ç1 ) (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that lam exempt from Contractor's License Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes (3 No I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (Include name address / phone / contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name / address / phone / contractors' license number): S. I will provide some of the work, but I have contracted (hired) the following persons to provide the work Indicated (include name / address / phone / type of work): OWNER SIGNATURE: DAGENT DATE:___________ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there Is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: Lender's Address: ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Dyes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above Information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for Inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations overS'O' deep and demolition or construction of structures over 3 stories In height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void If the building or work authorized by such permit Is not commenced within 180 daysjrorrf the date f such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of L80Uays (5ec1ion406.4.4 Uniform Building Code). APPLICANT SIGNATURE: "7 DATE: 314-5'119 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 76,9-8558 Email: BuiIdingtCarlsbadCa.gov 8-2 Page 2 of 2 Rev. 06/18 Permit Type: BLDG-Commercial Application Date: 08/01/2019 Owner: P D G CARLSBAD 59 LIMITED Work Class: Tenant Improvement Issue Date: 08/28/2019 Subdivision: CARLSBAD TCT#85-24 UNIT#04 Status: Closed - Finaled Expiration Date: 05/19/2020 Address; 1900 Aston Ave, 120 Carlsbad, CA 92008-7308 IVR Number: 20728 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 1010412019 1010412019 BLDG-44 106503-2019 Partial Pass Peter Dreibelbis Reinspection Incomplete RoughlDuctslDampe rs Checklist Item COMMENTS Passed BLDG-Building Deficiency Prelim HVAC duct sealing at Rm 164-166, Yes 169-172 only BLDG-Building Deficiency Prelim HVAC duct sealing at Rm 167-168. Yes see card for additional notes 10121/2019 1012112019 BLDG-85 T-Bar, 108099-2019 Failed Michael Collins Reinspection Complete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, not per plan No 1012312019 1012312019 BLDG-85 T-Bar, 108353-2019 Passed Michael Collins Complete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, not per plan No BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 1112112019 1112112019 BLDG-Fire Final 106913.2019 Passed Felix Salcedo Complete Checklist Item COMMENTS Passed FIRE- Building Final Yes 11127/2019 11/2712019 BLDG-Final 112302-2019 Passed Paul York Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes November 27, 2019 Page 2 of 2 Permit Type: BLDG-Commercial Application Date: 08/01/2019 Owner: P D G CARLSBAD 59 LIMITED Work Class: Tenant Improvement Issue Date: 08/28/2019 Subdivision: CARLSBAD TCT#85-24 UNIT#04 Status: Closed - Finaled Expiration Date: '05/19/2020 Addreès: 1900 Aston Ave, 120 Carlsbad, CA 92008-7308 IVR Number: 20728 Scheduled Actual : Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 0812912019 08129I2019 BLDG-84 Rough 102494.2019 Partial Pass Michael Collins Reinspection Incomplete Combo(14,24,34,44) Checklist Item. COMMENTS Passed BLDG-14 Partial wall frame at Rm. 161 265-174, see Yes - Frame-Steel-Bolting-Welding card for header frame requirements. (Decks) BLDG-34 Rough Electrical Yes 0910312019 0910312019 BLDG-84 Rough 102819.2019 Partial Pass Chris Renfro Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed .BLDG-14 Partial wall frame at Rm. 161, 265-174, see Yes Frame-Steel-Bolting-Welding card. Correction of double header box beam (Decks) complete BLDG-34 Rough Electrical Yes 0911012019 09110I2019 BLDG-17 Interior 103376-2019 Partial Pass MlchaelCollins Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Walls only at Rm. 161, 164-174. Does not Yes include the custodial closet. 0911712019 09117I2019 BLDG-84 Rough 104474.2019 Passed Michael Collins Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-14 Partial wall frame at Rm. 161, 265-174, see Yes Frame-Steel-Bolting-Welding card. Correction of double header box beam (Decks) • complete BLDG-14 At custodial closet only Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout • Yes BLDG-34 Rough Electrical • Yes BLDG-34 Rough Electrical Yes 0912512019 09125I2019 BLDG-44 105394.2019 Partial Pass Michael Collins Reinspection Incomplete RoughlDuctslDampe • rs Checklist Item COMMENTS Passed BLDG-Building Deficiency Prelim HVAC duct sealing at Rm 164-166, Yes 169-172 only 0912612019 09126I2019 BLDG-44 105509-2019 • Partial Pass Michael Collins Reinspection Incomplete RoughlDuctslDampe rs Checklist Item COMMENTS • Passed BLDG-Building Deficiency Prelim HVAC duct sealing at Rm 164-166, Yes 169-172 only BLDG-Building Deficiency Prelim HVAC duct sealing at Rm 167-168, Yes see card for additional notes November 27, 2019 • • Page 1 of 2 EsGil A SAFEbulittompany DATE: 8/12/2019 0 APPLICANT U JURIS. JURISDICTION: Carlsbad PLAN CHECK #.: CBC2019-0376 SET: I PROJECT ADDRESS: 1900 Aston Ave. #120 PROJECT NAME: M2 Office Tenant Improvement The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. Li The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. Li The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Li The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. Li The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. Li The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. Li EsGil staff did advise the pplicant that the plan check has been completed. Person contacted: / 4nP \Telephone #: Date contacted: / (b))Email: Mail Telephone Fax on Li REMARKS: By: Jason Pasiut Enclosures: EsGil 8/5/2019 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 (DO NOT PAY- THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2019-0376 PREPARED BY: Jason Pasiut DATE: 8/12/2019 BUILDING ADDRESS: 1900 Aston Ave. #120 BUILDING OCCUPANCY: B, F-i, S-i BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 3909 46.51 181,808 Air Conditioning Fire Sprinklers TOTAL VALUE 181,808 Jurisdiction Code Icb Ordinance 1997 UBC Building Permit Fee LiJ 1997 UBC Plan Check Fee Type of Review: P Complete Review r Structural Only fl Other Repeats I U EsGil Fee r Repetitive Fee . r Hourly 1Hr. @ * F F Comments: Sheet 1 of 1 , KasaiConsulting An EMS Soons Company 6670 Lico Lul 0im, *LC92O11, v 760929.9974 I 77W03fl05 SiA'g.CUn March 13, 2019 RECEIVED Mr. Michael Epsten AUG 282019 Diversified Properties CITY OF CARLSBAD 505 Loma Santa Fe Drive BUILDING DIVISION Suite 200 Solana Beach, CA 92075 Subject: 1900 ASTON AVENUE ASBESTOS INSPECTION CARLSBAD CA Mr. Epsten: At the request of Diversified Properties, Kasai Consulting performed an asbestos survey and sampling at the above referenced site on March 5, 2019. The survey and sampling event was conducted to determine if any suspect asbestos containing materials are present within the planned new tenant space inside the existing building located at 1900 Aston Ave. in Carlsbad. Survey and Sampling Process Mr. Rob Timmons, CMC ACAC Board Certified Microbial Consultant, conducted a visual inspection for suspect asbestos containing materials that may be disturbed during the construction process. During the survey and subsequent sampling the following was observed and recorded: The materials being impacted during the planned tenant improvement are limited to interior features and minor roof modifications for mechanical systems. Observed interior suspect asbestos containing materials include acoustic ceiling panels, multiple types of floor coverings, cove base mastic at base of walls, floor mastic, and drywall systems. During the survey process representative bulk samples were collected from random selected locations representing potential variations in each material type. Samples were submitted to EMiLab P&K in San Diego for PLM analysis on a 48 hour turn-around time. Laboratory PLM analysis of the bulk building material samples indicated there was no asbestos detected (ND) within any of the representative collected samples from the interior and roof. Based on the visual inspection of the site, identification of the homogeneous sampled building material and laboratory analysis, the materials being impacted during the retrofit process within the interior of the structure and roof are not going to disturb asbestos containing materials during the process. kKasaiConsulting 670Lncntel 0in, taLCA9201. v ?60.92999?4 f 7751O3flO5 awIn9wn If additional materials are identified that were not visible during the inspection the construction process T&T should be notified so that representative samples can be collected and analyzed. A copy of the laboratory analytical results, sample chain or custody and sample location map are attached for reference purposes. Limitations: Kasai provided these services consistent with the level and skill exercised by members of the profession currently practicing under similar conditions. This report is intended for the sole use of designated representatives of General Atomics in conjunction with this specific project. The intent of the report is to aid the construction planners in identification of potential asbestos containing materials. The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users, and use or re-use of this document, the findings, conclusions, or recommendations is at the risk of said user. Although every attempt has been made to identify all areas of potential asbestos containing materials, the inspection techniques used are inherently limited in the sense that only full demolition procedures will reveal all building materials of a structure and therefore all areas of potential variable conditions and materials. The passage of time may result in a change in the environmental characteristics at this site. This report does not warrant against future operations or conditions that could affect the results, findings, conclusions and recommendations expressed in this report that are based only on conditions that were observed during Kasai's inspection of the site on March 5, 2019. Thank you for this opportunity to be of service. If you have any questions, please contact us at 619.654.4156. Sincerely, Kasai Consulting Robert M. Timmons CAC # 96-2071, DPH I/A 23563 CMC ACAC Board Certified Microbial Consultant KasaiConsutting AnE11SSoonsComny €7OLnnLi3l Qc,rt4CA2Ol1, , 780929 9974 I 775.703 ?705 TKasäiCbnsuWng 'AnEHS Soons ComrnY -=-T , 7929W4 1T157032703. svflacu Attachment 1: Lab Analysis and COC EM Lab P&K P'A TestAmerica Company Report for: Mr. Robert Timmons T&T Consulting, Inc 6128 Laport Street La Mesa, CA 91942 Regarding: Project: 0305196-1900 Aston Ave TI; Asbestos Inspection EML ID: 2111288 Approved by: Dates of Analysis: Asbestos PLM: 03-07-2019 Approved Signatory Diane Green Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267) All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested. EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the clients customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liabili ty may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor. EMLabP&K,LLC EMLab ID: 2111288, Page 1 of 13 Client: T&T Consulting, Inc C/O: Mr. Robert Timmons Re: 0305196-1900 Aston Ave TI; Asbestos Inspection ASBESTOS PLM REPORT EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.em1ab.com Date of Sampling: 03-05-2019 Date of Receipt: 03-07-2019 Date of Report: 03-08-2019 Total Samples Submitted: 45 Total Samples Analyzed: 45 Total Samples with Layer Asbestos Content> 1%: 0 Location: WB/JC-01, Lobby conf. room drywall Lab 113-Version: 998742 1-1 Sample Layers Asbestos Content White Drywall ND White Joint Compound ND Sample Composite Homogeneity: Moderate Location: WB/JC-02, Office at door drywall Lab ID-VersionS: 9987422-I Sample Layers Asbestos Content White Drywall with Brown Paper ND White Joint Compound ND Composite Non-Asbestos Content: 7% Cellulose Sample Composite Homogeneity: 1 Moderate Location: WB/JC-03, Office N. wall drywall Lab ID-VersionS: 9987423-1 Sample Layers Asbestos Content White Drywall with Brown Paper ND White Joint Compound ND Composite Non-Asbestos Content: 7% Cellulose Sample Composite Homogeneity: Moderate Location: WB/JC-04, Office area west wall drywall Lab 1D-Version: 9987424-1 Sample Layers Asbestos Content White Drywall ND Yellow Woven Material (Mesh) ND White Joint Compound ND Composite Non-Asbestos Content: 2% Glass Fibers Sample Composite Homogeneity: IModerate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -"x" after the Lab IN with a value greater than I indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2111288, Page 2 of 13 EMLab P&K 'ø 8304 ClairemontrMesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Client: T&T Consulting, Inc Date of Sampling: 03-05-2019 C/O: Mr. Robert Timmons Date of Receipt: 03-07-2019 Re: 0305196-1900 Aston Ave TI; Asbestos Date of Report: 03-08-2019 Inspection ASBESTOS PLM REPORT Location: WB/JC-05, R and D area N. wall drywall Lab ID-Version: 9987425.1 Sample Layers Asbestos Content White Drywall with Brown Paper ND White Joint Compound ND Composite Non-Asbestos Content: 7% Cellulose Sample Composite Homogeneity: lModerate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. NI) means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLa], P&K, LLC EMLab ID: 2111288, Page 3 of 13 EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Client: T&T Consulting, Inc C/O: Mr. Robert Timmons Re: 0305196-1900 Aston Ave TI; Asbestos Inspection Date of Sampling: 03-05-2019 Date of Receipt: 03-07-2019 Date of Report: 03-08-2019 ASBESTOS PLM REPORT Location: WB/JC-06, Warehouse area S. wall drywall Lab ID-Versioi4: 9987426-1 Sample Layers Asbestos Content White Drywall ND White Joint Compound ND Sample Composite Homogeneity: Moderate Location: WB/JC-07, Warehouse west wall drywall Lab ID-Versioi4: 9987427-1 Sample Layers Asbestos Content White Drywall with Brown Paper ND White Joint Compound ND Composite Non-Asbestos Content: 7% Cellulose Sample Composite Homogeneity: I Moderate Location: WBIJC-08, NW warehouse rm. drywall Lab ID-Versioi4: 9987428-1 Sample Layers Asbestos Content White Drywall with Brown Paper ND White Joint Compound ND Composite Non-Asbestos Content: 7% Cellulose Sample Composite Homogeneity: Moderate Location: WB/JC-09, West hall wall at door drywall Lab ID-VersionS: 9987429-1 Sample Layers Asbestos Content White Drywall ND White Joint Compound ND Sample Composite Homogeneity: Moderate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -'x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x'. EMLab P&K, LLC EMLab ID: 2111288, Page 4 of 13 Client: T&T Consulting, Inc C/O: Mr. Robert Timmons Re: 0305196-1900 Aston Ave TI; Asbestos Inspection ASBESTOS PLM REPORT Location: CM-01, Carpet mastic/office floor EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.em1ab.com Date of Sampling: 03-05-2019 Date of Receipt: 03-07-2019 Date of Report: 03-08-2019 Lab ID-Version: 9987430-1 Sample Layers Asbestos Content Yellow Mastic with Gray Compound ND Composite Non-Asbestos Content: 1% Cellulose 1% Glass Fibers Sample Composite Homogeneity: Moderate Location: CM-02, Carpet mastic/office floor Lab ID-VersionS: 998743 1-1 Sample Layers Asbestos Content Gray Compound ND Yellow Mastic ND Composite Non-Asbestos Content: 1% Cellulose 1% Glass Fibers Sample Composite Homogeneity: I Moderate Location: CM-03, Carpet mastic/office floor Lab ID-Version: 9987432-I Sample Layers Asbestos Content Gray Compound ND Yellow Mastic ND Composite Non-Asbestos Content: 1% Cellulose 1% Glass Fibers Sample Composite Homogeneity: I Moderate Location: FLOOR-01, R and D floor at concrete seams yellow and gray Lab ID-Versioi4: 9987433-1 Sample Layers Asbestos Content Yellow Mastic -Like Material ND Sample Composite Homogeneity: Good The test report shall not be reproduced except in fill, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A 'Version" indicated by -"x" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2111288, Page 5 of 13 Client: T&T Consulting, Inc C/O: Mr. Robert Timmons Re: 0305196-1900 Aston Ave TI; Asbestos Inspection EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emIab.com Date of Sampling: 03-05-2019 Date of Receipt: 03-07-2019 Date of Report: 03-08-2019 ASBESTOS PLM REPORT Location: FLOOR-02, R and D floor at concrete seam Lab ID-Versioi4: 9987434-I Sample Layers Asbestos Content Gray Concrete ND White Compound ND Composite Non-Asbestos Content: 1% Glass Fibers Sample Composite Homogeneity: 1 Moderate Location: FLOOR-03, East R and D floor thin set gray Lab ID-VersionS: 9987435-1 Sample Layers Asbestos Content Gray Compound with Yellow Mastic ND Sample Composite Homogeneity: Good Location: FLOOR-04, R and D yellow/green mastic Lab ID-VersionS: 9987436-1 Sample Layers Asbestos Content Yellow Mastic with Paint ND Sample Composite Homogeneity: Good Location: FLOOR-05, Old shower pan fiberglass mat R and D floor Lab ID-VersionS: 9987437-1 Sample Layers Asbestos Content White Semi-Fibrous Material ND Composite Non-Asbestos Content: 35% Glass Fibers Sample Composite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -"x" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2111288, Page 6 of 13 EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Client: T&T Consulting, Inc Date of Sampling: 03-05-2019 C/O: Mr. Robert Timmons Date of Receipt: 03-07-2019 Re: 0305196-1900 Aston Ave TI; Asbestos Date of Report: 03-08-2019 Inspection ASBESTOS PLM REPORT Location: FLOOR-06, NW warehouse long room tile/carpet mastic and leveling compound Lab ID-VersionS: 9987438-1 Sample Layers Asbestos Content White Compound with Yellow Mastic ND Sample Composite Homogeneity: Moderate Location: FLOOR-07, Gray floor tile long room Lab 1D-Version: 9987439-1 Sample Layers Asbestos Content Yellow Mastic ND Gray Floor Tile ND Sample Composite Homogeneity: Moderate Location: FLOOR-08, Floor tile warehouse office Lab ID-Versiont: 9987440-1 Sample Layers Asbestos Content Yellow Mastic ND Gray Floor Tile ND Sample Composite Homogeneity: Moderate Location: FLOOR-09, Carpet/tile mastic yellow/green/warehouse office Lab 1D-Version: 998744 1-1 Sample Layers Asbestos Content Yellow Mastic with Paint ND Sample Composite Homogeneity: Moderate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2111288, Page 7 of 13 Client: T&T Consulting, Inc C/O: Mr. Robert Timmons Re: 0305196-1900 Aston Ave TI; Asbestos Inspection EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Date of Sampling: 03-05-2019 Date of Receipt: 03-07-2019 Date of Report: 03-08-2019 ASBESTOS PLM REPORT Location: FLOOR-10, Floor tile/warehouse office Lab ID-Versioi4: 9987442-1 Sample Layers Asbestos Content Yellow Mastic with Gray Compound ND Gray Floor Tile ND Composite Non-Asbestos Content: <1% Cellulose Sample Composite Homogeneity: Moderate Location: FLOOR-11, R and D entry corner yellow mastic Lab ID-Versions: 9987443-1 Sample Layers Asbestos Content Yellow Mastic ND Gray Cementitious Material ND Sample Composite Homogeneity: Moderate Location: FLOOR-12, Office area NE corner floor tile Lab ID-VersionS: 9987444-1 Sample Layers Asbestos Content Yellow Mastic ND Gray Floor Tile ND Yellow Mastic ND Sample Composite Homogeneity: Moderate Location: CBM-01, Cove base mastic yellow/office area west wall Lab ID-Version:: 9987445-1 Sample Layers Asbestos Content Brown Paper ND White Compound ND Yellow Mastic ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Moderate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -"x" after the Lab IN with a value greater than I indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2111288, Page 8 of 13 Client: T&T Consulting, Inc C/O: Mr. Robert Timmons Re: 0305196-1900 Aston Ave TI; Asbestos Inspection EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Date of Sampling: 03-05-2019 Date of Receipt: 03-07-2019 Date of Report: 03-08-2019 ASBESTOS PLM REPORT Location: CBM-02, Cove base mastic yellow/office at center Lab ID-Versioi4: 9987446-1 Sample Layers Asbestos Content Brown Paper ND White Compound ND Yellow Mastic ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: I Moderate Location: CBM-03, Cove base mastic yellow/office E. wall Lab ID-Version: 9987447-1 Sample Layers Asbestos Content Brown Paper ND White Compound ND Yellow Mastic ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: I Moderate Location: CBM-04, Cove base mastic yellow/R and D area west wall Lab ID-VersionS: 9987448.1 Sample Layers Asbestos Content Brown Paper ND Yellow Mastic ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate Location: CBM-05, Cove base mastic yellowlR and D area S wall Lab ID-Versioi4: 9987449-I Sample Layers Asbestos Content Yellow Mastic ND Sample Composite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. NI) means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -'x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2111288, Page 9 of 13 EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Client: T&T Consulting, Inc Date of Sampling: 03-05-2019 C/O: Mr. Robert Timmons Date of Receipt: 03-07-2019 Re: 0305196-1900 Aston Ave TI; Asbestos Date of Report: 03-08-2019 Inspection ASBESTOS PLM REPORT Location: CBM-06, Cove base mastic yellow/warehouse long room wall Lab ID.Versioi4: 9987450-1 Sample Layers Asbestos Content Yellow Mastic ND White Compound ND Sample Composite Homogeneity: Moderate Location: CP-01, 2x4 ceiling panellR and D entry Lab ID.Version1: 9987451.1 Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND Composite Non-Asbestos Content: 50% Cellulose 20% Glass Fibers Sample Composite Homogeneity: Good Location: CP-02, 2x4 ceiling panel/R and D entry Lab 1D.Version: 9987452.1 Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND Composite Non-Asbestos Content: 50% Cellulose 20% Glass Fibers Sample Composite Homogeneity: Good Location: CP-03, Warehouse ce11ing12x4 panel Lab ID-Version: 9987453-1 Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND Composite Non-Asbestos Content: 50% Cellulose 20% Glass Fibers Sample Composite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2111288, Page 10 of 13 EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Client: T&T Consulting, Inc CIO: Mr. Robert Timmons Re: 0305196-1900 Aston Ave TI; Asbestos Inspection Date of Sampling: 03-05-2019 Date of Receipt: 03-07-2019 Date of Report: 03-08-2019 ASBESTOS PLM REPORT Location: CP-04, 2x2 ceiling panel/lobby ceiling Lab 1D-Version: 9987454-1 Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND Composite Non-Asbestos Content: 50% Cellulose 20% Glass Fibers Sample Composite Homogeneity: Good Location: CP-05, 2x2 ceiling panel/lobby ceiling Lab ID-versionS: 9987455-1 Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND Composite Non-Asbestos Content: 50% Cellulose 20% Glass Fibers Sample Composite Homogeneity: Good Location: CP-06, 2x2 ceiling panel/lobby ceiling Lab ID-VersionS: 9987456-1 Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND Composite Non-Asbestos Content: 50% Cellulose 20% Glass Fibers Sample Composite Homogeneity: Good Location: PEN-01, Roof penetration mastic base of pipes and vents Lab 1D-Version: 9987457-1 Sample Layers Asbestos Content Black Roofing Material ND White Fibrous Material ND Composite Non-Asbestos Content: 201/6 Cellulose 5% Polyethylene 5% Synthetic Fibers Sample Composite Homogeneity: I Moderate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of 'Y'. EMLab P&K, LLC EMLab ID: 2111288, Page 11 of 13 Client: T&T Consulting, Inc C/O: Mr. Robert Timmons Re: 0305196-1900 Aston Ave TI; Asbestos Inspection EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Date of Sampling: 03-05-2019 Date of Receipt: 03-07-2019 Date of Report: 03-08-2019 ASBESTOS PLM REPORT Location: PEN-02, Roof penetration mastic base of pipes and vents Lab ID-Version: 9987458-1 Sample Layers Asbestos Content Black Roofing Material ND White Fibrous Material ND Composite Non-Asbestos Content: 20% Cellulose 5% Polyethylene 5% Synthetic Fibers Sample Composite Homogeneity: I Moderate Location: PEN-03, Roof penetration mastic base of pipes and vents Lab ID-Version: 9987459-1 Sample Layers Asbestos Content Black Roofing Material ND White Fibrous Material ND Composite Non-Asbestos Content: 20% Cellulose 5% Polyethylene 5% Synthetic Fibers Sample Composite Homogeneity: Moderate Location: CompRoll-01, Gray rolled composite roofing Lab ID-Versioi4: 9987460-I Sample Layers Asbestos Content Black Roofing Tar ND Black Roofing Material ND Composite Non-Asbestos Content: 30% Glass Fibers Sample Composite Homogeneity: Good Location: CompRoll-02, Gray rolled composite roofing Lab ID-Version:: 9987461-1 Sample Layers Asbestos Content Black Roofing Tar ND Black Roofing Material ND Composite Non-Asbestos Content: 30% Glass Fibers Sample Composite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. lnhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLabP&K,LLC EMLab ID: 2111288, Page 120f13 EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emIab.com Client: T&T Consulting, Inc Date of Sampling: 03-05-2019 C/O: Mr. Robert Timmons Date of Receipt: 03-07-2019 Re: 0305196-1900 Aston Ave TI; Asbestos Date of Report: 03-08-2019 Inspection ASBESTOS PLM REPORT Location: CompRoll-03, Gray lli mposiie roofing Lab 1D-Version: 9987462-1 Sample Layers Asbestos Content Black Roofing Tar ND Black Roofing Material ND Composite Non-Asbestos Content: 30% Glass Fibers Sample Composite Homogeneity: 1 Good Location: FANDUCT-01, Roof metal duct coating/white Lab ID-Version: 9987463-I Sample Layers Asbestos Content Off-White Fibrous Material with White Coating ND Composite Non-Asbestos Content: 20% Cellulose Sample Composite Homogeneity: Moderate Location: FANDUCT-02, Roof metal duct coating/white Lab ID-VersionS: 9987464-1 Sample Layers Asbestos Content Off-White Fibrous Material with White Coating ND Composite Non-Asbestos Content: 20% Cellulose Sample Composite Homogeneity: Moderate Location: FANDUCT-03, Roof metal duct coating/white Lab ID-VersioT4: 9987465-1 Sample Layers . Asbestos Content Off-White Fibrous Material with White Coating ND Composite Non-Asbestos Content: 20% Cellulose Sample Composite Homogeneity: Moderate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2111288, Page 13 of 13 CHAIN OF CUSTODY gk EM Lab P&K www.EMLabPk.com Ciwny HitJb NJ: I 836 OlrtoyAvenua, CheLTy lull. NI 00003 • (866) 811-1984 Phaentx, AZ: 151)1 !Nest Knudsen Drive. Phoenix, AZ 85027 (900)651 4802 San 8nrno6CA 1150 BayhiU Drive. *100. San BMW. CA 9056 '(668)288-6G5$ 1 CONTACT INFORMATION Company T&T Consulting, Inc - Addmrr,: 6128 LapOI - ... - - - -- Special In5b1Ictions: NcnCullurabl - c.4e h11jjJuu1L11I111I01JJi1iliI!IiIJlI l4eq irate - I C49sWe'- And i;4.----)21 1288 -- Trap Bulk —. — — CA 91942 Contact M. rwuii u inirnan CL Imam 619-741-7409 I -1111 t - -— Pa..IIrHhiMATTON TURNAROUPID11.MECODES (TAT) I Lici . 1U j I'M `R-Catepohriffle: *G1 Sampling I i Code: Number f:- . Sa w SAMPLE ID ....,.DESCRIPTION FAULT) usnes.teIv9aJte(4prnnr .onWéeflda.will be. nsidetèd iraaeivedih next business day. Please aleit us in advance ofweekend.analysia $ U u I.u.Lk8 . 13 4 OcIr 6 8 1 iDay Rush • .TA roteJ. •l.•--.• Vol me/A • :. NOTES (as applicable). moday.Témp.R.et &ZIA ç:::::: ,,' at !' 'U - BloCaesette S - Mdei*en S - Surface Air San .Olih di LEvPgcoDE$ - -Contact Plate TTapo In-C SPOre Trep: SW _Swab W-1 ea. Aflerpnm, - iii... B-Bulks ISO. ByavbnlitthlO this Chain Of Cu .DATE&11ME II you agi*e to be bound by the terme and oondlons set forth atw4tv.eml2bpkcom1Lem.htrnl CopfGht (02002-2003 EMLab P&k • (::J:) 0c2O176 XGV.23 RevivrOPMAS Pe11Q. CHAIN OF CUSTODYO EMLab. www.EMLabPk.com P&K WEATHER Rein Snmv - REUESThO lift thU1ll NUIt Cy Hill. NJ: 1936OMeyAvenue, Cherry NO. NJo8cJoa '(uaa71-1sa4 PhoenIx, AZ. 1501 West Knvseri Difte, Phoenix, AZ 55027 • (800) 8614502 aoderdte - L 111e8vY I See runo1 CA: 115OBayhOlDive.#10OSaeBw no. CAg40B6 *(86&)888.8653 trap VIM.Duet.. Bulk — CONTACT INFORMATiON - - - Comininir T&T Consultina. Inc. Lcith. 6128 Labort Street. La Mess CA 91942 I ISU&. lVII. I '.j&II L I U Lii IJJI I __ __ ne:619-741-7409 - -. A-1 rJINt'UMATIaN - VP (TA I ,. ' %')O - RusheceIvedafter2m -or I I i I I eGt ID. - TD - standard EFAULT)- - on waekands will be . -- Am ectbac.: A4r ik4la4 ND-NextBusta;aflay cdnsidoredreceivedthfllext: ; . - Samplingleat - btieiness day. Please sled us in w C TAr Code: Dte&TIme: 3'j SD.5arne8ue1nessbayRush I CA I3 C I WH - WeeketoII0y . needs. . rl FL SAMPLE ID ESCRlPTION TyPe iAbova) (ri temp. (rime of —''.-:..:: r4 0 c3t,1Jc1caR. 5t -_--. (&iLn I 1 4- t I -— LH I — o'em SA1iIPIE TYPE CODES - RELINQUISHED BY DATE & TIME 1EGEiVED BY -- DATE S TIME BC - BloCadset[et' jCP.ContPT-Tape O.Oust -- _________ A1SAnqrse fL;T:: LswSvisib w-Wa SASSurface Air Sanieler Bw B Bulk O-Otho Ely submItling this Chain of Custody. ycu agree to be bound by the cmii arid condltlonG se1brth at vww.bpkccmftemuLho51 Coht20D2-2005 EMLabP&I( Ow. 22110170 Rffe.23 fl IigjQ$ P408 2aff.0A CHAIN OF CUSTODY EM P&K F— Clem www.EMlabPK.com ..3 lNone Ligh t Cheny Hill. NJ: 1936 Olney Avenue. Cber,y Hilt, NJ 08003 * (888) 571-1984 • odarate Pho.nlx. AZ: 1501 West Kntld8en Dilve. Phoenbc. AZ 85027 * (803) 851-4502 Son Bruno, CA: 1150 SayhiD D*to 10l), San &vno, CA 54(366 • (866)886.8855 :-. CONTAC7INFORMATIO. co,iparw T&T Consulting, Inc. - --Addww:6128 Lapott S'eet, La Mesa, CA-91942 - jspeczal lnVuctiotis: ,a.- ri Lvr1Ii WI! • & WI 4 P 11111 II L one: 619-741-7409 V Ituratilcil Cuftill IS '1 pbte Tape SloCmeW%22111288 I Ttap 9k I W ftr. Bulk. DuEt. - - -- Kim rvsci!a I ISPO AAUT64C -- jectLID: -- -' eject Dew: elect •D Code: 03, ) Number V SAMPLE ID j QESCRIP1JON TURN AROUND TIME -- CQDEs-(rAr) . . all a -E s z i .Stasidard(DEFAULT) mcalved ftet2Pl1 01" oiweeendswjIIhe -NextBusinessDay .4o8lderedreo!,thenaxt. business4ay.Pleaseatertus:in 5 j E S . V - SameBusiesDayRush I advanceo1weekendan8lysts needs.. ..... it t 2.1 K: 3 I-Weekondfllooday :sample Toe* Telel..TAT. . . INOTES • ( ayTempHetc) 5 ! -- - _1i L :" {d"ff€tA4Ie12- J . V I ILl L I H Li I V SAMPLE TYPE CODES RELINQUISHED bY DATE & TIME RECEIVED BY DATE & TIME . taord.... Jsw:sw r-Tspe 4w.w 2L .. - 9A103 V [Wi 1 SAS-SurSce P1rSam1er B - Bull.SO -W ______________________ V V V • V VVV - By 4001ftling thh 01181111 YV& 9SM0 to be bond by the sand wnditions setfarth atwwweMIabpkcomftnn&-hIrW Cayfttd @2002.2008 EMI.ab P8K • . () O,300I76 'tO2 .WVUU P4.Ifl.O, CHAIN OF CUSTODY gk EMLaI P&.9( www.EMLabPk.com Ch.ny NO, NJ: 198 Olney Avenue. C$eiy HI. NJ 08003 • (686)871.4884 Phoenix. AZ: 1501 VdWt Knudsen 04ve, Phoenix. AZ 85027 '*O0 6514802 Sail Bmno CA: 1150 Sa$iil Dye. #IQQ, Son Bruno.CA 94066 * (88$) 8884653 WEWTHER Fog R3108nowlWnd Clow REQUESTED LWOW Moderate 11288 Heavy I Trap Bulk Bulk. Duet aOP(rACTINFRMAnON. - Copny T&T Consult, Inc. Address: 8128 Lapor ,, special Iflstuctlos: .uruui iw.. t •iiuiii iui u . Phone: 619-741-7409 TURN AROUND 7M5 CODES (rAT) 4 4b 1910 - 00LT_ M440 49 AWE. Rushes received &ter2pmor 33 00 C Project ID: M so*uj p.. ,rrft'trl rlut th Project SrnpI. — - ZiCode; chifa&rno; L SSe P0 Number WH - W :- DESCRIPTJOPJ • — i,ç iZ p A1ZA iL (1 ah /tJ& fwl iaLg 9e fj A~JJA* rA p/ç9G4fLi -:bnisdaYeusin:PTO '15 Day Rush advance of weekend an êIyis ,! ,7 I tray •• • needs-.. Total • •.s (A6ove) •(TicTofTom ;RHek.) .SAMPLE.TPE VOBES •' :•. REUNOUISHED8Y .DATE & TIME RECEIVED BY DATE &TI1 011. B-8oC665eff" cp .CuntctI late T.Tape D-.Cust ______ -. - *4-5t - KL ---.- 1SAitdotten ST - Spero Trap, I •- SiSwab W-WaterEdon. Aftomog, SAS SwfaceAilSaxnhIer 8us1sd. B Bulk SO Sail - - 0-Other I L BysubmNing this Chain of CItQdy, you a5Me to be bound bythe terms and GoeWJUan set fovUi etwvAvern1abplc,comftarTns.h CopelgPd2D02-2008 EMLul, P&K • (!) Do920I78 Rau: R4Y4I14O P8941911.6A CHAIN OF CUSTODY d EMI P& K' F ISnewVMniC 2r www.EMLabPK.com . L1ght None Cherry 1410, NJ: 1936 OheyAveawe, Clteiry Hlil, NJ 0803 '(866)871-4984 Moderate Phooiil; A?: 1501 West Krnjdeen Dñve, Phaernx. AZ 8502? '1800)6514= 5aM Bpwto, CA: 1150 Bayhi Diiite, 0100. Sari Bruno, CA 94066 866) 6884663 - CONTAcT IN FORMA7ION - - Icompany. T&T Consulting. Inc. -Address: 1A: 6128 Laport Strejj..a Mesa, CA 91942 — - — -- iSx & 1nstructIoñs FtVQVEME Non-Cull 9pece1 11 Ill Due 1288 contact IM onen 'immons . -1W . r~ _ Pioir;619-741-74O9 TURNAROUNDTlMEC0D0-irAfl 6404,51q— 1W AOMA TX - RurncsvedAflar2arnet va I ' cjectID -- STD- Meat Des Pr]act SempIing Q Code: [Dote £ The I ' -SID s PO Number SAMPLE 1D . :. bRlPTIoN * fr4 -o1 T MDap fAoF1 Od 1( ...AI I2k#1'l -- ••, '• SAMPL.IYPECODES . .RELINQULSHEDBv DAIE&TIME . RECEIVEOBY DATE&1ME - BC-BIoCassette #-SporeTrap., .ConPktejT'TaPe 0-Dust - i- - - 3/1 IO't ST AIS-Andeasen W-WaQrn. Allargem. SAS AiiSawi isid B Bulk SO Soil 0-Other: By submitting this Chain of Custody. you agree to be bauhd by tie terms eiid candilil set forth aLt emIabpk.comft8ITn.tdmI Cepyalght 2002-2011M ElótLab F&K .a2QO1Th Re- d:JIrs PeTD1,O& 000sderedr000ivedthe next business day. Please atell in ad,aciceof weekend anaIysis heeds. -. *tL !- A Z. Ii Total bJBf TF Oimeorà: pRH,etc) I tKasaiConsuIting MEJSSo$uUonsconpany vla 929-W4, f 775-703-210-N Attachment 2: Site Drawings PROPOSED FLOOR PLAN 1900 ASTON AVE., CARLSBAD SUITE 100-22,825 RSF Vzt,,,v- N.Jt-~ a3 PROPOSED FLOOR PLAN WVTI% I - I I - %,!I4C -4 1 PROPOSED FLOOR PLAN 6f•0I 1.o2#. - r ,p4ri4 1:;: 7.1 , , KasaiConsuWng An ia On,,mo-24 I 57O3fl3, IIIpgwp Attachment 3: CAC Certification STATE OF CALIFORNIA Edmund G. Brown, Jr. Governor DEPARTMENT OF INDUSTRIAL RELATIONS Division of Occupational Safety and Health Asbestos Unit 2424 Arden Way, Suite 495 Sacramento, CA 95825-2417 (916) 574-2993 Office (916) 483-0572 Fax httD://www.dir.ca.aov/dirdatabases.html actu1dir.ca.aov 610282071C 132 T & T Consulting, Inc. October 03, 2018 Robert M Timmons 6128 LciportSt. La Mesa CA 91942 Dear Certified Asbestos Consultant or Technician: Enclosed is your certification card. To maintain your certification, you must abide by the rules printed on the back of the certification card. Your certification is valid for a period of one year. If you wish to renew your certification, you must apply for renewal at least 60 days before the expiration date shown on your card. [8 CCR 341.15(h)(1)1. Please hold and do not send copies of your required AHERA refresher renewal certificates to our office until you apply for renewal of your certification. Certificates must be kept current if you are actively working as a CAC or CSST. The grace period is only for those who are not actively working as an asbestos consultant or site surveillance technician. Please contact our office at the above address, fax number or email; of any changes in your contact/mailing information within 15 days of the change. Siflçerely, Jeff errell Senior Safety Engineer Attachment: Certification Card cc: File State of California Division of Occupational Safety and Health Renewal - Card Attached (Revised 10/24/2012) SAN DIEGO REGIONAL 'fJn RECORD ID OFFICE USE ONLY (CC) HAZARDOUS MATERIALS 'PLAN CHECK #__________________ QUESTIONNAIRE SP DATE I I Business Name Business Contact Telephone # M2 Ingredients, Inc David Crist 866-740-6874 Project Address Cd lAa Carrsbad Cb0 Zip Code I APN# 900 Aston Avenue 92008 I Mailing Address City Stale Zip Code I Plan File# 5931 Priestly Drive, Ste. 101 Carlsbad CA 92008 I Project Contact Appbca nt i E-rnail Telephone # Kimberly A. Krenek, AlA kmberly@krenekdesign.com 858-558-5935 The following questions represent the facility's activities, NOT the specific project description. aicare by circling tne item, wnetner your Dusiness will use, process, or store any must contact the Fire Protection Agency with jurisdiction prior to plan submittal. any or me items are Occupancy Rating: Facility's Square Footage (including proposed project): Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards Flammable/Combustible Liquids 7. Pyrophorlcs 11. Highly Toxic or Toxic Materials 15. None of These. Flammable Solids 8. Unstable Reactives 12. Radioactives Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: YES NO (for new construction or remodeling projects) 0 j Is your business listed on the reverse side of this form? (check all that apply). 0 Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? 0 El Will your business store or handle carcinogens/reproductive toxins In any quantity? 0 El Will your business use an existing or install an underground storage tank? 0 Will your business store or handle Regulated Substances (CalARP)? 0 Will your business use or install a Hazardous Waste Tank System (ritte 22. Article 10)? S. 0 l] Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to lithe answer to any of the Diego, CA 92123. CalARP Exempt Date Initials CalARP Required I Date Initials E3 CalARP Complete Date InItials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD: Any YES answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 aocdcomomsdcountv.ca.aov (858) 586-2650). [No stamp required if 01 Yes and Q3 Yes and Q4-Q6 No]. The following questions are intended to identify the majority of air pollution Issues at the planning stage. Projects may require additional measures not Identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except - those with more than one building on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate bums; residences forming part of a larger project. (Excludes garages & small outbuildings.] YES NO l 0 WIll the project disturb 160 square feet or more of existing building materials? 0 Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. (ANSWER ONLY IF QUESTION I or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 0 [ (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required ID working days prior to commencing asbestos removal. Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (m.sdaocdprg/lnfo/lacls/oemiilsodfl for typical equipment requiring an APCD permit. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school boundary Briefly describe business activities: BrIeljy describg prgposed project: Warehousing,blending and packaging of medicinal mushroom produc S ,j7 Tfapt'j.pgrad$7o leased property I declare under penalty of perjury that to the best of my knowledge and ~-~rueZ and correct. David Grist Name of Owner or Authorized Anent Sigadiurg of Owner orAuthorizeci Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: FOR OFFICAL USE ONLY: DATE: / BY: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY - COUNTY-HMD' APCD COUNTY-HMD APCD COUNTY-HMD APCD -A stamp in ms cox oniv exempts ousinesses trom compteting or upoating a riazaruous iviarenais iiusuness man. urner permitting requirenienis may sun apply. HM-9171 (08/15) County of San Diego - DEH - Hazardous Materials Division Contact information of person completing this checklist (if different than above): Name: Contact Phone: (city of Carlsbad CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov PURPOSE This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. Unless none of the requirements apply, the completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy- related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. A If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. .4 Details on CAP ordinance requirements are available on the city's website. Application Information Project Name/Building BP No.: - Permit No.: V\-21 3 _________ Property Address/APN: c1 o Applicant Name/Co.: Applicant Address: - Contact Phone: cc?, Contact Email: Company name/address: Contact Email: Applicant Signature: Date: B-50 Page 1 of 3 Revised 04/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For residential alterations and additions to existing buildings, contact the building counter for the building permit valuation. Building Permit Valuation (BPV) $ Construction Type I Complete Section(s) Notes: I Residential O New construction 1A O Alterations: 0 exempt BPV 2! $60,000 O Electrical service panel upgrade 1A 1A 1-2 family dwellings and townhouses with attached garages only BPV ?- $200,000 1A Multi-family dwellings only where interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 'Nonresidential New construction 113 and 2 2' Alterations 2 1. Electric Vehicle Charging Residential New construction and major alterations (or electric panel upgrade)* Please refer to Carlsbad Ordinance CS-349 when completing this section. 0 One and two-family residential dwelling or townhouse with attached garage: 0 One EVSE ready parking space required 0 Exception: 0 Multi-family residential: 0 Exception: Total Parking Spaces Proposed EVSE Spaces Capable Ready Installed Total Calculations: Total EVSE spaces =10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x.50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces - EVSE Installed (EVSE other may be 'Capable, °Ready" or lnstalled.") *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation ~! $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. D Nonresidential new construction (includes hotels/motels) 0 Exception:_____________________________________ Total Parking Spaces Proposed EVSE Spaces Capable Ready Installed Total Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces 0-9 1 1 10-25 2 1 26-50 4 2 51-75 6 3 76-100 9 5 101-150 12 6 151-200 17 9 201 and over 10 percent of total 50 percent of Required EV Spaces Updated 4/12/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist 2. 0 Transportation Demand Management (1DM) I List each proposed nonresidential use and gross floor area (GFA) allocated to each use. Employee ADT/1 000 square feet is selected from the table below. Use GFA ___ Employee ADT for first 1,000 S.F. Employee ADT for each subsequent 1,000 S.F. Total Employee ADT OFckre' 3q09 _ Total 31).1 6 If total employee ADT is greater than or equal to 110 employee ADT, a TOM plan is required. TOM plan required: Yes 0 No ''- Employee ADT Estimation for Various Commercial Uses Use 1,000 S.f 1000 S.f 20 20 Restaurant II II 8 4.5 4 3.5 Industrial Manufacturing 4 3 Warehousing 4 1 1 Unless otherwise noted, rates estimated from ITE Trip Generation Manual, lOmEdition 2 For all office uses, use SANDAG rate of 20 ADT/1 ,000 sf to calculate employee ADT Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses maybe subject to special consideration Sample calculations: Office: 20,450 sf 20,450 sf/1000 x 20 = 409 Employee ADT Retail: 9,334 sf First l,000sf=8ADT * 9,334 sf- 1,000 sf= 8,334 sf (8,334 sf / 1,000 x 4.5) + 8 = 46 Employee ADT Updated 4/12/2019 3 DIVERSIFIED PROPERTIES 1825 GILLESPIE WAY SUITE 102 EL CAJON, CALIFORNIA 92020 (619) 258-2900 www.diversifiedprop.net August 20, .2019 Linda-Ontiveros City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 RE: 1900 Aston Avenue, Suite 120 Carlsbad, CA Linda, Kimberly Krenek has asked me to provide the City of Carlsbad with some background on bur building at 1900 Aston Avenue with respect to the creation of suite 120. For many years the subject building has been occupied by Zimmer Dental. A few years ago Zimmer renewed their lease but only for half of the building leaving the remainder of the building (approximately 22,000 square feet) for a second tenant. Through our marketing efforts we came to an agreement for 18,500 square feet of the available space which was permitted as suite 100 and leased to M2 Ingredients. This left approximately 4,000 square feet of vacant space that was identified as suite 120. I hope this provides the information you need to complete the processing of our building permit request for suite 120. Thank you, Robert C. Tschantz CBC2019-0376