HomeMy WebLinkAbout1901 CAMINO VIDA ROBLE; 100; CB930876; PermitSuite: 100
BUILDING PERMIT
10/13/^3 10:33
Page 1 of 1
Job Address: 1901 CAMINO VIDA ROBLE
Permit Type: INDUSTRIAL TENANT IMPROVEMENT
Parcel No: 212-092-20-00 Lot# s
Valuation: 130,425
Construction Type: VN
Occupancy Group: B2 Reference**:
Description: 5217 SF OFFICE MERRILL LYNCH
Permit No:
Project No:
Development No :
C-PRMT
CB930876
A9301248
933-00
Appl/Ownr : KIM, SUNG
515 S. FLOWER STREET #1250
LOS ANGELES, CA 90
*** Fees Required ***
213 623-2164
Entered By: DC
Fees :
Adjustments:
Total Fees:
Fee description
Building Permit
Plan Check
Strong Motion Fee
* BUILDING TOTAL
Enter "Y" for Plum
Each Install/Repai
* PLUMBING TOTAL
Enter "Y" for Electr
Remodel/Alter Per AMP1
* ELECTRICAL TOTAL
Enter 'Y' for Mechanica
Install Furn/Ducts/Heat Pil
Each Exhaust Fan
* MECHANICAL TOTAL
ected & Credits ***
.00
486.00
933.00
Ext fee Dat.
9. 00
6.50
748
486
27
1261
20
7
27
10
75
85
15
18
13
46
. 00
.00
.00
.00
.00 Y
.00
.00
.00 Y
.00
. 00
.00 Y
. 00
.00
. 00
FINAtfAPPROVAL
INSP. /*/ DATE.
CLEARANCE
CITY OF CARLSBAD
2075 Us Mms Dr., CtebbKl, CA 92009 (619) 438-1161
PERMIT APPLICATION
City of Carlsbad Building Department
2075 Las Pains Dr., Carlsbad, CA 92009 (619) 438-1161
I. PERMIT TYPE
A -BCommerciaT QNew Building Btenant Improvement
B - D Industrial D New Building D Tenant Improvement
C - D Residential D Apartment DCondo D Single Family Dwelling DAddirion/Alteration
D Duplex D Demolition D Relocation D Mobile Home D Electrical D Plumbing
D Mechanical D Pool D Spa D Retaining Wall D Solar D Other
2. PROJECT INFORMATION
PLAN CHECK NO.
EST.VAL
PLAN CK DEPOSIT.
VALID. BY 4> <=-
DATE
FOR OFFICE USE ONLY
Address
Nearest Cross Street
Building or suite NO.
Ait-
LEGAL DESCRIFriON bu Ml vision Name/iNumoer Unit No.Phase No.
CHECK BLLOW If SUtiMll ihU:
& 2 Energy Calcs D 2 Structural Calcs
ASSESSOR'S PARCEL
DESCRIPTION OF WORK $JgWOV&l>
SQ. FT. Ty.?-\~l #
Q 2 Soils Report D 1 Addressed
EXISTING USE
OF STORIES -flA/*?
Envelope
PROPOSED USF
a. UUNIAL.*! pcjuun (.it aiiterent rrom applicant]
NAME *^ ADDRESS
\ CITY STATE ZIP CODE DAY TELEPHONE
\4-APPUCANT LJCONIKAUIOK U AGEN I f UK CON LKAL.HJK LJOWNtK Jfil^UhN I fUR OWNtK
\ NAME SuNSr (ClM ADDRESS Cjffy *>. ^U>l/J^fZ. <-r ^4^- l^O ^
NciTY \/i>3 Av&l&le<> STATE Cfl ZIPCODE ^0e~1( DAYTELEPHONE WV £>2? - £/ fc^
&. FKOFERTY OWNER
NAME /ZiV OlLfT ^ ^^
CITY STATE
NAME M£-C>C>l^J^i^^>^^f^-t^'"^Tr^"j 3Vi-«:
^Cx^ y /^N ^ ^~~^f^^ *-*C~
STATE LIC. #^2
lc_ ADDRESS
ZIP CODE
r7^ ADDRESS 7&S/ *?*
'sfc/f= ZIPCODE ^2~}2^>
t^S°> LICENSE CLASS S^A"
DAY TELEPHONE
DAY TELEPHON^V^O 2&£~~~t 'F&f
CITY BUSINESS LIC. # ^fa-T^'V''^ A«> ^ ^V
UtblUNLK NAMt
CITY STATE ZIP CODE f<3?7f DAY TELEPHONE^f^aj --Z^STATE UC. #
7. WORKERS* CUMPENIsAnON
Workers Compensation Declaration: I hereby affirm that I have a certificate of consent to seU-msure issued by the Director of Industrial
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY POLICY NO.EXPIRATION DATE
Certificate or Exemption: I certify tnat in me performance ot tne work tor which this permit is issued, I shall not employ any person in any manner
so as to become subject to the Workers' Compensation Laws of California.
SIGNATURE DATE
8. OWNER-BUILDER DECLARATION
Owner-Builder Declaration: I hereby aftirm that I am exempt from the Contractors License LawTor the following reason:
D 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale.).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects
with contractor(s) licensed pursuant to the Contractor's License Law).
D I am exempt under Section Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
D YES D NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
D YES D NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
D YES D NO
ff ANYOFTHEANSWEI«AREYES,AFmALCERTmCATEOFC)CaJPANCYMAYNO 1989 UNLESS THE APPLICANT
HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DKTTUCT.
9. UUNtflKUtrilON LENlilNU
I hereby attirm that there is a construction lending agency tor tne pertortnance ot the work, tor which this permit is issued l.aec JW/OJ L.IVU uxiej.
LENDER'S NAME LENDER'S ADDRESS
10. APPLICANT CERTOTCATIOH
I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and !state laws
relating to building construction. 1 hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS
AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SATO CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSIIA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by
such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code).
APPLICANTS SIGNATURE
Applicant PINK: Finance
RECEIVED ftuv I 2
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M WATER
PLAN CHECK*: CB930876 DATE: 11/18/93
PERMIT*: CB930876 PERMIT TYPE: ITI
PROJECT NAME: 5217 SF OFFICE MERRILL LYNCH
ADDRESS: 1901 CAMINO VIDA ROBLE SUITE* 100
CONTACT PERSON/PHONE*: RS/JEFF COHN/265-1801
SEWER DIST: CA WATER DIST: CA
=============
INSPECTED
BY: M.JH
INSPECTED
BY:
INSPECTED
BY:
COMMENTS :
A ' J DATE j£2f? ./^ft^JU- INSPECTED: //^ /-i APPROVED v DISAPPROVED
DATE
INSPECTED: APPROVED DISAPPROVED
DATE
INSPECTED: APPROVED DISAPPROVED
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT* CB930876 FOR 11/18/93
DESCRIPTION: 5217 SF OFFICE MERRILL LYNCH
TYPE: ITI
JOB ADDRESS: 1901 CAMINO VIDA ROBLE
APPLICANT: KIM, SUNG PHONE;
CONTRACTOR: PHONE:
OWNER: PHONE:
REMARKS: RS/JEFF COHN/265-1801 INSPECTOR
SPECIAL INSTRUCT: PAGER #530-6668 / FIRE IS SCHEDULED T
1 & 2 PM...SO PLEASE COME BY AFTER THIS TIME.
INSPECTOR AREA TP
PLANCK* CB930876
OCC GRP B2
CONSTR. TYPE VN
STE: 100 LOT:
213 623-2164
BETWEEN
TOTAL TIME:
—RELATED PERMITS—PERMITS TYPE
AS930069 ASTI
STATUS
ISSUED
CD LVL DESCRIPTION
19 ST Final Structural
29 PL Final Plumbing
39 EL Final Electrical
49 ME Final Mechanical
ACT COMMENTS
***** INSPECTION HISTORY *****
DATE DESCRIPTION
110993 Rough/Ducts/Dampers
110393 Frame/Steel/Bolting/Welding
110393 Rough Electric
110393 Rough/Ducts/Dampers
110193 Frame/Steel/Bolting/Welding
110193 Rough Electric
110193 Rough/Ducts/Dampers
102093 Interior Lath/Drywall
101893 Frame/Steel/Bolting/Welding
101893 Rough Electric
101593 Frame/Steel/Bolting/Welding
101593 Rough Electric
ACT
AP
AP
AP
CO
CO
NR
CO
AP
AP
AP
AP
AP
INSP
TP
PK
PK
PK
TP
TP
TP
TP
TP
TP
TP
TP
COMMENTS
CORRECTIONS COMPLETE
SEE JOB CARD
T-BAR
NEW WALLS & PATCHES
WALLS (NEW)
NEW WALLS & DEMO
NEW WALLS ONLY
CITY OF CARLSBAD
BUILDING DEPARTMENT
DATE.
NOTICE 438-3550
2075 LAS PALMAS DRIVE
-T^~T
LOCATION
TtME.
PERMIT NO.,
.^figfey/frag^)
FOR INSPECTION CALL 438-3101. RE-INSPECTION FEE DUE?
FOR FURTHER INFORMATION, CONTACT
YES
BUltDING INSPECTOR CODE ENFORCEMENT OFFICER
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE:
JURISDICTION:
PLAN CHECK NO:
PROJECT ADDRESS:
PROJECT NAME:
- 876 SET: IZZT
/9fl/Ui£>A wtf /Qr>
CHECKER
JFILE COPY
QUPS
rjDESIGNER
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with"the jurisdiction's building codes when minor deficien-
cies identified secant are resolved and
D
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
|| Esgil staff did advise applicant that the plan check has1— been completed, person contacted: .
Date contacted:
REMARKS: (^
Telephone t
VfJLlFY IN TteL FiE~LD T>MT T>f_
Cvte,
By: ____^__ESGIL CORPORATION
DGA DCM DPC
Enclosures
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619)560-1468
DATE:
JURISDICTION: __
PLAN CHECK NO:
PROJECT ADDRESS
PROJECT NAME:
CARLSBAD
- 81C SET:
DAPPL:
'CO
PLAN CHECKER
DFILE COPY
QUPS
[jDESIGNER
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck. -
ETJ The check list transmitted herewith is for your informationSB . . .The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
suwt
SOUTH t^-SO 05 CA
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted:
REMARKS:
Telephone #
By:Enclosures
ESGIL CORPORATION
IGA US CM D PC
FLAN CORRECTION SHEET
TENANT IMPROVEMENT
FLAN CHECK NO.:
JURISDICTION: CARLSBAD
TO:A£-C H
PROJECT DATA
OCCUPANCY:
BUILDING USE:
TYPE OF CONSTRDCnOK:
ACXOAL AREA;
1ZT f
ALLOWABLE AREA:
STORIES
A/O
HEIGHT:
SPRINKLERS:
OCCUPANT LOAD:
REMARKS:
Date plans received by jurisdiction:
Date plans received by Esgil Corporation:
Date initial plan check completed:
Applicant contact person:
FOREWORD: PLEASE READ
Flan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department
or other departments. Code sections cited are
based on the 1991 UBC.
The circled items listed need clarification,
modification or change. All items must be
satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec.
303(c), 1991 Uniform Building Code, the approval of
the plans does not permit the violation of any
state, county or city law.
To speed JJP the recheck process, note on this list
(or a copy) where each correction item has been
addressed, i.e.. plan shegt^ specification, etc^
Be sure to enclose the marked UP list vhen you
submit the revised plans.
NOTE: PAGE NUMBERS ARE NOT III SHJUENCK AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS HERE DELETED.
LIST NO. 41 CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1991 UBC
Please make al 1 corrections on the original
tracings and submit two new sets of prints, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, CA 92123,
(619) 560-H68.
Please make all corrections on the original
tracings and submit two new sets of prints, to:
The jurisdiction's building department.
Indicate on the Title Sheet of the plans, the
name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302(d).
Each sheet of the plans must be signed by the
person responsible for their preparation, even
though there are no structural changes.
Business and Professions Code.
Flans and calculations shall be signed by the
California state licensed engineer or architect
y
Please
include the California license number, seal,
date of license expiration and date plans are
signed. Business and Professions Code.
Provide the correct address and suite number of
tenant space on the plans. Section 302(d).
Provide a note on the site plan indicating the
previous use of the tenant space or building
being remodeled. Section 302.
When the character of the occupancy or use
changes within a building, the building must be
made to comply with current Building Code
requirements for the new occupancy. Please
provide complete details to show the building
with comply. Section 502.
UBC Section 304 requires the Building Official
to determine the total value of all
construction vprk proposed under this permit.
The value shall include all finish vork,
painting, roofing, electrical, plumbing,
heating, air conditioning, elevator, fire
extinguishing systems and any other permanent
equipment. Please provide a signed copy of the
designer's or contractor's construction cost
estimate of all vork proposed.
Provide a plot plan showing the distance from
the bui Id ing to the property 1 ines and the
location of tenant space (or remodel) within
the building.
On the first sheet of the plans indicate:
Type of construction of the existing building,
present and proposed occupancy classifications
of the remodel area and the occupant load of
the remodel areas and the floor where the
tenant improvement is located.
Provide a note on the plans indicating if any
hazardous materials will be stored and/or used
within the building which exceed the
quantities listed in UBC Tables 9-A and 9-B.
A complete description of the activities »nd
processes that will occur in this tenant space
should be provided. A listing of all
hazardous materials should be included. The
materials listing should be stated in a form
that would make classification in Tables 9-A
and 9-B possible. The building official may
require a technical report to identify and
develop methods of protection from hazardous
materials. Section 901(f).
If control areas are used for exceeding the
exempt amounts of hazardous materials from
Tables 9-A and 9-B, they shall be constructed
of not less that required for a one-hour
occupancy separation. Section 404.
The number of control areas vithin a building
used for retail/wholesale stores shall not
exceed two; the number of control areas in
buildings with other uses shall not exceed
four. Footnote 1, Tables 9-A and 9-B.
The aggregate quantity of any hazardous
materials "in use" and "in storage" shall not
exceed the quantity listed in Tables 9-A and
9-B for "storage". Footnotes 2 and 3, Tables
9-A and 9-B.
Provide a statement on the Title Sheet of the
p lans that this project shall comply with
Title 24 and 1991 UBC, UMC and UPC and 1990NEC.
Provide a fully dimensioned floor plan showing
the size and use of all rooms or areas within
the space being improved or altered. Draw the
plans to scale and indicate the scale on the
plan. Section 302(d).
Indicate the use of all spaces adjacent to the
area being remodeled or improved.
Show any existing fire rated area separation
walls, occupancy separation walls, demising
walls, shafts or rated corridors. Identify
and provide construction details for proposed
new fire rated walls.
Specify on the plans the fire ratings of
assemblies to protect penetrations or proposed
openings in existing or new fire vails, floor-
ceiling assemblies or roof-ceiling assemblies.
8/4/92
Identify existing vails to be removed,
existing walls to remain and proposed new
vails. Identify bearing vails, non-bearing
vails, and shear vails.
Show safety glazing in the following
locations, per Section 5406(d):
a. Where the nearest edge of glazing is
within a 24-inch arc of either side of a
door in a closed postion (unless there is
an intervening vail between the door and
the glazing or if the glazing is 5'-0" or
higher above the walking surface).
b. Glazing greater than 9 square feet with
the bottom edge less than 18" above the
floor and the top edge greater than 56"
above th« floor (unless the glazing is
more than 36" horizontally away from
walking surfaces ...or -if a complying
protective bar is installed).
c. Glazing in shower and tub enclosures
(including windows within 5 feet of tub
or shower floor).
243 Provide a section view of all new interior
partitions. Show:
4-ttiiig ul ilLfflh.. Indicate
gauge for metal studs. Specify
manufacturer and approval number or
s—V indicate "to be ICBO approved".
( (b) J Method of attaching top and bottom plates
\~-*S to structure. (NOTE: Top of partition
must be secured to roof or floor framing,
unless suspended ceiling has been designed
for partition lateral load).
(09 Wall sheathing material and details of
r attachment (size and spacing of
fasteners).
(A)) Show height of partition and suspended
ceiling, and height from floor to roof
framing or floor framing. 15" TWt^ z- '/*• fc
Provide notes and/or details to show that the
floor and wall finish in toilet rooms are
surfaced with a smooth hard non-absorbent
material extending five inches up the wall.
Similar surfacing shall be provided on the
wall* from the floor to a height of 4 feet
around urinals and within vater closet
compartments. Section. 51p(b).
Note on the plans: "All interior finishes must
comply with Chapter 42 of the UBC". Specify
"Class f lame spread rating (minimm)
for ."
27./ Note on plan that suspended ceilings shall
comply with UBC Tables 47-A and 23-P.
2S'.) In buildings having floors and roofs of wood
frame construction, other than dwelling or
hotel occupancies, draft stop the area between
the ceiling and floor above so that no
concealed space exceeds 1,000 s.f. and no
horizontal dimension exceeds 60 L.F. (if space
has sprinklers, then 3,000 s.f. and 100 L.F.).
Section 2516(f).
/•
?•
t
In buildings having floors and roofs of wood
frame construction, other than dwelling or
hotel occupancies, draft stop the area between
the ceiling and . roof._._aboy_e_ so that no
concealed space exceeds 3,000 s.f. and no
horizontal dimension exceeds 60 L.F. (if space
has sprinklers, then 9,000 s.f. and 100 L.F.)-
Section 2516(f).
Storage areas exceeding 1000 sq. ft. in
connection with wholesale or retail sales
shall be separated from the public area by a
one-hour occupancy separation. If the entire
building has an automatic sprinkler system,
then the occupancy separation need not be
provided. Section 702(c).
An automatic sprinkler system shall be
installed in rooms used by the occupants for
the consumption of alcohol and in accessory
uses where the total area of such unseparated
roons and assembly uses exceeds 5000 square
feet. Section 3802(c).
The tenant space and new and/or existing
facilities serving the remodeled area oust be
accessible to and functional for the
physically disabled. See the attached
correction sheet. Title 24, Part 2.
The width of the required level area on the
side into which doors swing shall extend 24
inches past the strike edge for exterior doors
and 18 inches past the strike edge for
interior doors. Section 2-3304, Title 24.
Specify lever-type hardware for passage doors
on floors accessible to the disabled. Section
2-3304, Title 24.
If both sexes will be employed and the number
of employees exceeds four, provide separate
toilet facilities for men and women. If "both
sexes will be employed and the total number of
employees will not exceed four", and only one
restroom is provided, note the words in
quotation above on the floor plan. Section
705(c).
A -hour occupancy separation is
..occupancy andrequired between.
the ^occupancy. Table 5-B.
Ducts penetrating occupancy or area separation
vails must have fire dampers. Section 4306
(J).
In areas where the occupant load exceeds
two exits are required. See
. Table 33-A.
,29. Provide an exit analysis plan (may be 8 1/2" x
11" or any convenient size).
Exits should have a minimum separation of one-
half the maximum overall diagonal dimension of
the building or area served. Section 3303(c).
&&QV\&£$ T^O 6X/T-5
~Jt>
15
7/8/92
The maximum number of required exits and their
required separation must be maintained until
egress is provided from the structure. Section
3303(a).
Rooms with more than 10 occupants nay have one.
exit through one adjoining room. Revise exits
to comply. Section 3303(e). T7t£-
Exit signs are required whenever two exits are
required. Show all required exit sign
locations. Section 3314 (a).
44-f Show that exits are lighted with at least one
' foot candle at floor level. Section 3313(a).
Show the locations of existing exits from the
building and show the path of travel from the
remodel area to the existing exits.
Note on the plans: "All exits are to be
openable from inside without the use of a key
or special knowledge". In lieu of the above,
in a Group B occupancy, you may note "Provide a
sign on or near the exit doors reading THIS
DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS".
This signaga is only allowed at the main exit.
Section 3304(c).
Exit doors should be a minimum size of 3 feet
by 6 feet 8 inches with a minimum door swing of
90 degrees. Maximum leaf width is U feet.
Section 3304(f).
Exit doors should swing in the direction of
egress when serving an occupant load of 50 or
more or when serving any hazardous area.
Section 3304(b). Applies to door(s)
Regardless of occupant load, a floor or landing
not more than 1/2 inch below the threshold is
required on each side of an exit door used for
disabled access (may be 1" maximum where not
used for disabled access). Section 3304(i).
Doors should not project more than 7 inches
into the required corridor width when fully
opened, nor more than one-half of the required
corridor width when in any position. Section
3305(d).
Revolving, sliding and overhead doors are not
permitted as exit doors if the occupant load
exceeds 9 or the exit door serves a hazardous
area. Section 3304(h).
Provide panic hardware in Group A,E,H-l,H-2,H-3
and I occupancies. Chapter 33.
Double acting doors are not allowed when
serving a tributary occupant load of more than
100, or when part of a fire assembly, or part
of snoke and draft control assemblies or when
equipped with panic hardware. Section
330Mb).
J
Corridors must provide continuous protection
to the exterior of the building.
Interruptions by an intervening room is not
permitted. Foyers, lobbies or reception rooms
constructed as required for corridors are not
considered intervening rooms. Section 3305.
$B. Corridors and exterior exit balconies serving
( 10 or more occupants must be a minimum 44
inches wide and 7 feet high to the lowest
\*v* projection. Corridors serving less than 50
rii6tt) occupants nay be a minimum of 36 inches in
* width. Section 3305(b).
When two exits are required, dead end
corridors and exit balconies are limited to 20
feet. Section 3305(e).
57.J Corridors serving 30 or more occupants shall
have walls and ceilings of one-hour
construction. Show compliance or clearly show
on plans which of the following exceptions has
been satisfied:
a. Corridors greater than 30 feet wide when
the occupants have an exit independent
from the corridor.
b. Exterior sides of exterior exit
balconies.
c. Corridor walls and ceilings need not be
of fire-resistive construction within
office spaces having an occupant load of
100 or less when the entire story in
which the space is located is equipped
with an automatic sprinkler system
throughout and smoke detectors are
installed within the corridor in
accordance with their listing.
d. Within office spaces occupied by a single
tenant, partial height partitions which
form corridors and which do not exceed 6
feet in height need not be fire
resistive, provided they are constructed
in accordance with Section 1705 and are
not more than three fourths of the floor-
to-ceiling height. Section 3305 (g).
Section 3305(g), Exception 5, cannot be used
for non-rated corridors in a fully sprinklered
office space if the occupant load in the space
exceeds 100.
Section 3305(g), Exception 5 does not apply to
common corridors where the corridor serves as
an exit for non-office areas (manufacturing,
warehouse, etc.).
Section 3305(g), Exception 5 is applicable
only for corridors on one floor; the corridors
on the lower level(s) must be rated if these
lower corridors have openings into them from
other levels.
f-
6*.
5/28/92
If non-rated corridors are used per Section
3305(g), Exc. 5, provide a reference to the
corridors on the floor plan, noting:
1. Corridors are non-rated per Section
3305(g), Exception 5.
2. Smoke detectors shall be maximum 30" on
center.
3. Power supply shall be dedicated branch
circuit. Circuit disconnecting means
shall be accessible only to authorized
personnel and shall be clearly marked FIRE
ALARM CIRCUIT CONTROL, with a lock-on
device.
If a tenant space utilizes Section 3305(g),
Exception 5, then that tenant space shall be
separated from adjacent ''spaces by a demising
vail constructed as for a one-hour corridor
vail.
Clearly show where the non-rated corridor
system terminates and a rated corridor system
commences.
One-hour fire-rated corridors shall have
interior door openings protected by tight-
fitting smoke and draft control assemblies
rated 20 minutes, except openings in interior
walls of exterior exit balconies. Doors shall
be maintained self-closing or be automatic-
closing by action of a smoke detector per
Section 4306(b). Doors shall be gasketed to
provide a smoke and draft seal where the door
meets the stop on sides and top. Section
3305(h).
Total area of all openings, except doors, in
any portion of an interior corridor, shall not
exceed 25 percent of the area of the corridor
wall of the room which it is separating from
the corridor. Such openings shall be protected
by fixed glazing listed and labeled for a fire*
protection rating of at least 3/4-hour.
Section 3305(h).
Show rated corridors, lobbies, reception or
foyers cross-hatched on the floor plans.
Provide a complete architectural section of
the corridor, or exterior exit balcony,
showing all fire-resistive materials and
details of construction for all floors, walls,
ceiling and all penetrations. Section
3305(g).
Show the location of fire dampers. Provide
fire dampers at duct penetrations of fire-
rated occupancy and area separations, shafts
and corridor ceilings. Combination fire/smoke
dampers are required at duct penetrations of
rated corridor walls. Section 4306(j).
7s'
If a room with an exhaust fan has a door
opening into a rated corridor, show how make-
up air will be provided to the room. The door
cannot be undercut, nor can a louver in the
door be provided. Section 3305(h)l.
If building exceeds two stories and has an
elevator opening into a rated corridor, show
how the smoke and draft control provision of
Section 3305(h) will be met. Either provide a
separated elevator lobby or a second door at
the elevator entry meeting the provision.
Section 3305(j).
If a second door is provided at the elevator
entry, note that it will be readily openable
from the car side without a key, too 1 or
special knowledge or effort. Section 5106.
New provisions in Chapter 43 of the 1991 UBC
require special treatment of penetrations at
fire-resistive assemblies. Provide typical
details on the plans showing how the fire-
resistive integrity will be maintained at the
following conditions (Include the
manufacturers' names and ICBO numbers (or
equal) for any sealant):
A. THROUGH-PENETRATIONS (through the entire
assembly):
1. Fire-resistive bearing vails and/or
vails requiring protected openings shall
have penetrations protected with through-
penetration fire stops having an F-
rating, T-rating or complying with UBC
Standard 43-1, depending on their
locations, sizes and combustibility.
2. Fire resistive floor/ceiling assemblies
shall have penetrations protected with
through-penetration fire stops having and
F-rating, T-rating or complying with UBC
Standard 43-1, depending on their sizes,
combustibility and whether the
penetrations are in walls above.
B. MEMBRANE-PENETRATIONS (through only one
side of an assembly):
1. Fire-resistive walls (whether bearing or
not and whether requiring fire protected
openings or not) shall have penetrations
protected with membrane-penetration fire
stops having an F-rating or complyingwith UBC Standard 43-1, depending on
their size and combustibility. Limited
steel electrical outlet boxes (not
exceeding 16 sq. in., nor more than 100
sq. in. for any 100 sq. ft. of wall)
require no protection.
2. Fire-resistive ceilings shall have no
penetrations, except for noncombustible
sprinkler pipes and steel electrical
outlet boxes as described above.
NOTE: The plans should indicate the various
fire-stop ratings required for all
penetrations.
Provide a note on the plans stating
"Penetrations of fire-resistive walls, floor-
ceilings and roof-ceilings shall be protected
as required in UBC Sections 4304 and 4305".
8/4/92
7/
8£.
'Provide evidence of Health Department approval
(for restaurants or for tenants using X-ray
equipment).
If nonflammable supply cylinders for medical
gas systems are located inside buildings, show
how they comply with UBC Section 702(c)4.
ELKr-reiCAL
Submit plan showing location of all panels.
Submit panels schedules.
Submit electrical load calculations
Indicate existing main service size.
Indicate existing total rain service load.
Indicate new additional leads.
Indicate wiring method, i.e. EMI, metal flex.
Show exit signs en the electrical lighting
plan(s). As per Section 3313 and 3314 of the
1991 UBC, provide two sources of power to exit
signs and exit illumination.
Provide receptacle(s) within 25' of KVAC
units. UMC Section 5C9.
Provide multiple switch lighting controls per
Title 24, Part 6.
KECSAKTCAL
Provide mechanical ventilation in all rooms
capable of supplying a minimum of 5 cubic feet
per minute of outside air with a total
circulation of not less than 15 cubic feet per
minute per occupant. Section 605 and 705, UBC.
Provide mechanical plans showing existing and
proposed HVAC equipment, ducts and access to
equipment.
Detail access and working c learances to HVAC
equipment.
99/
Detail disposal of main condensate drainage
from air conditioning units. (UMC Section
510)
Detail overflcv (secondary) condensate
discharge from air conditioning units that are
in a ceiling space. (UMC Section 1205)
Fire rated corridors are not to be used to
convey air to or from rooms . UMC Section
1002.
FUMBING
Provide gas line plans and calculations,
showing pipe lengths and gas demands. UPC
Section 1219.
Provide drain, waste and vent plans.
Provide water line sizing calculations. UPC
Section 1009.
Detail how floor drain trap seal is to be
maintained. UPC Section 707 (floor drain trap
prining).
Show P & I valve on water heater and detail
drain line route from P & T valve to the
exterior. UPC Section 1007(e).
Show 1/4" per 12" slope on drain and waste
lines. UPC Section 407.
Provide a drinking fountain at each floor
level in assembly occupancies (except drinking
and dining establishments). UBC Section 605.
Note on the plans that new water closets and
associated flushcneter valves, if any, shall
use no nore than 1.6 gallons per flush and
shall neet performance standards established
by the American National Standards Institute
Standard A112.19.2, and urinals and associated
flushometer valves, if any, shall use no more
than one gallon per flush and shall meet
performance standards established by the
American National Standards Institute Standard
A112.19.2. H & S Code, Section 17921.3(b).
QCERGY
iProvide complete energy design calculations,
including all existing design and new energy
design for this building. See attached non-
residential energy design checklist.
For remodels in an existing conditioned space,
show that the remodeled space will not use
more energy than the existing space or show
the remodeled space will conform to'latest
energy design standards.
CITY OF CARLSBAD SUPPJJMENT
Hoof mounted equipment must be screened and
roof penetrations should be minimized (City
?olicy SO-6).
No wiring is permitted on the roof of a
bu i 1 d ing and wiring on the exterior of a
building requires approval by the Building
Official. (City Policy)
6/25/93
roof-nounted equipment shall be concealed
view. Provide structural detailing for
the screening.
MTcrFTJAKEDOS
^Please see additional corrections or remarks
that follow.
106) To speed up the recheck process, note on this
list (or a copy) where each correction item has
been addressed, i.e., plan sheet, note cr
detail number, calculation page, etc.
Please indicate here if any changes have been
Bade to the plans that are not a result of
corrections from this list. If there are other
changes, please briefly describe them and where
they are located in the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
. J'es No
Ihe jurisdiction has contracted with Esgil
Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number
of 619/560-1^68, to perform the plan check for your
project. If you have any questions regarding these
plan check items, please contact
?£~TE frSCfrte at Esgil
Corporation
Ihank you.
Enclosures:
1.
2. ,
3.
6/25/93
U)inouwfl
u
•H
<M-Ho
0)
w
^3
CO
r*
mr»
^^
b
09
Op£
5 §E 3— tae >
< ob
F-. fflCO
1 18si*•» ^ue^ 3E *cO1 C£ o*3 J*« S
IM
-H
•aQ)*Ja.«uofl
J8
O^J
M01•H
*J-H
<M
•^UfflIM
JJ
C0)^" ffl1-E 3
jj V
W «
§ 1s 5o «
M 2*J flc -•01£ 01
1 B•H30-0) •b iH
QjjS
u
•o
•M
o
w
~o•H±>
ffl
-H
?.0901b
0)
75
„
3 •t compliance wisonable liardshipU S•H Q)b b*J C
W 3
b WO M01_, (Ja »
M -X "3_c 3
o. ^
b0) 0)^ J3q 3•^
01 «
»J
1 =5 •*•" -o•H
U >U OCl b~ B.
4J
•H Q^ ^S o£ b
s cannot be waibarriers Uiat pw >-»Cl (SU 00U 0)< f-H
•
CM
C X0) J3
§ -0
01>
• T*0) (0u 3
§ *••^ E»o cu o~<
c. -we S-H **iJ -H
ffl -^£ u•« w
r^ fl
•H >«y
fl £j
*M g0)
p 1 -—4-* *^C (Q
At »*OJ !>— - -^iance or equiva]access and equ;i— i
&jrao oo ja
X
^•owb
T*3O*ob
M•H
CO•H
*J
fflu•^IM
•H
*Jab
*i— i
ffl•rt
nforcement officIs Board.Cl ffl010) C..c a*j <
•a i
§ £0154J(0
(0 -^« 1;s o.
01 Ce?
*• • 1Jv> nb -4o Zo
2 8.ff^ HS' «n3.*in
•o Sg (7>i s"* i~i
R REMODELS:and exemptionsQ UQ c3 ob. -M1 i-i
<-H BH 0)t? UP KE w
!§la• ^S «
^ 0)
S °§ "•HU X•n u> oO IMb fflC. VI
•t-t
,
uco
•HJj
3
H
ft)
U•H£0)M
01•— iu
•H
fl)
bVUe01Minflc.d multi-storied01T3C
IM
- bg 0
0 U41 unW i^,
•w A£ Hi•a (Ufl -O
O
M 0C
fl V)•H —|^ 5u£30. **
* i0 0)—^V) J
0) 3u w•H<M -ing centers , ofiffice buildingsD. "O.O t)J= CW fl
«Hs01
•o
3Ob
OS
b
O
bOO•-<IM
JJUb•HIM
O5
;>o
M01A
•3
Q
01
1
fl
U•M
01
u1— 1
b MO b*J Ofl O> —01 *—•-<o) j;ui; 3o u
f otj
b u)Ufl 01UIM U
•H ffl
U) U
*J -HC — i01 d
S c.b•M u3 -acr -H
Cl >b Ob
xempt from theset available to p01 Oc0)b H
ffl -H
o
> e> s .,
ffl T1 > O O fflbOi^ObflXuo =; C.I-HUHW.Q 3
2a
e>03
a
e
p X
3bfl
•o0)
•H
0)•o
. 2
gf fr is required for remodels :01u
ffl
-*-H
frOu
uw0)u o remodeled area.->
^-i
0)
flbJJ
UHO
5
£
00
•HA!b
£
a
IQ
.*i-rf
J
J3
H*Ob
S
5
u
U9
J3b
U
•o
ub
O*Ju igto
Id
01 tM to remodeled area.6!UC2wc01
&s
b
U!0)U
flb*J
£
fl)
MbD
S
4J
•HXu
d
tffl
•oo
-^0)•o
b
00
•H£
0)u
MO•HiJ•H
rH
•H
UfflIM
Xbfl)u
•H
^
^
Sf•H
£uu
u0)
S"5.o
^H
014J
•oi
u
•HfflxJ
C
oIM
00c•H1
bO
TITLE 24 HANDICAPPED ACCESS CORRECTION LIST
Jurisdiction
Plan Check No.
References to section numbers with prefix "2" are to Title 24, California Code of Regulations, Part 2
(California Building Code). Prefix "3" is for Part 3 (California Electrical Code). Prefix "5" is for
Part 5 (California Plumbing Code).
Exemptions claimed for any item shall be requested in writing and shall include all data needed to
determine "unreasonable hardship" as described in Section 2-422.
SITE DEVELOPMENT
HANDICAPPED PARKING SPACES
a. Provide ..handicapped spaces,
2-7102(b)
b. Space shall be so located that
handicapped persons axe not compelled to
wheel or walk behind parked cars other
than his/her own. 2-7102(c)
c. Parking space shall be a minimum of 9
ft.xlS ft. with adjacent marked 5 ft.
loading zone. Double space shall be 23
ft. wide. Where a single space is
provided, the loading/unloading zone
shall be on the passenger side of the
vehicle. 2-7102(c).
d. Maximum slope of parking surface in any
direction shall not exceed 1/4" per
foot. 2-7102(e).
e. Parking space(s) shall be identified
with the International Symbol of
Accessibility on reflectorized sign
affixed to post or wall, and also
duplicated on parking surface (symbol to
be 36"x36" and painted at the back of
the parking stall). 2-7102(f)
f. Entrance to parking area (or at each
stall) shall have a sign stating that
unauthorized vehicle(s) parking in
handicapped space(s) may be subject to
tow-away. 2-7102(f)
g. If covered parking is provided, then a
reasonable portion of the total number
of stalls reserved for the disabled
shall also be covered. 2-7102(a)
h. Entrances to and vertical clearances
within accessible levels of parking
structures shall be 8 ft. 2 in. to anystructural member, duct or pipe.
2-7102(g)
CURB RAMPS
a. Curb ramps shall be located wherever
pedestrian path crosses curb. (2-
7103(a))
b. Curb ramp shall be 48" min. width (2-
7103(b)) with maximum slope of 1 in 12.
2-7103(d)
c. A level 48" min. depth landing is
required at top of curb ramps over
entire curb ramp width. 2-7103(d)
d. If no landing is provided, the slope of
flared sides shall not exceed 1 in 12.
2-7103{d)
e. Surface is to be slip
contrasting finish
sidewalk. 2-7103(f)
resistant and a
from adjacent
f. Border markings shall be 12" wide of
l/4"xl/4" grooves, 3/4" apart, located at
top and sides. 2-7103(h)
'WALKS
a. Site development and grading shall be
designed to provide access to primary
entrances and access to normal paths of
travel and where necessary to provide
access shall incorporate pedestrian
ramps, curb ramps, etc. 2-7101(a)
b. Walks sloping greater than 5% (1 in 20)
must comply with ramp requirements of
Sec. 2-3307. 2-3325(c)
c. Walk width shall be 48" minimum, and
shall have slip-resistant surfaces.
2-3325(a)
d. The maximum cross slope shall not exceed
1/4" per foot. 2-3325(a)3
Gratings
possible.
are not
2-3325(b)
allowed whenever
f. At each gate or door a 60"x60" level area
is required when the gate swings toward
the walk. 2-3325(e)
g. A 48"x44" deep level area is required
when the gate swings away froa the walk.
2-3325(e)
h. A 24" clear space is required at strike
side of gate or door. 2-3325(e)
PEDESTRIAN RAMPS
a. A path of travel with a slope greater
than 1 in 20 shall be considered a ramp.
2-3307(a)
b. The maximum slope shall be 1 in 12.
2-3307(c.l)
c. The width shall be 48" minimum. A
minimum width of 60" is required where a
ramp serves as a primary entrance to
buildings having an occupant load of 300
or more. Group R Occupancies may be 36"
when the occupant load is 50 or less. 2-
3307(b.l)
d. The surface of ramps shall be slip-
resistant. 2-3307(g)
e. A 60" intermediate landing is required
at maximum elevation change of 30" and
72" landing at each change of direction
(over 30 degrees). 2-3307(d.l)
f. Landings are required at top and bottom
of ramps. 2-3307(d.l)
g. Bottom landing shall be minimum of 72"
in the direction of travel. Fig. 2-33-
11A
b. Headroom of 80" minimum shall be
maintained for walks, corridors, aisles,
etc. 2-522m
JUB4JIM1JUICU i Vi.
etc. 2-522(f)
h. Top landing
2-3307(d.l)
shall be 60" x 60"
i. When' door swings onto top landing,
mininum depth of landing required is
door width plus 42". 2-3307(d.l.)
j. Top landing shall have 60" min. width
when door swings onto the landing, with
24" on strike side of door at exterior
ranp, or 18" at interior raop.
2-3307(d.l)
k. Ranp handrails are required on each side
of ramp, when slope exceeds 1 in IS. 2-
3307(e.l)
1. Ramp handrails shall be continuous,
located 30"-34" in height above racp
surface, with 12" extensions beyond top
and bottom, and the ends returned.
2-3307(e.l)
m. Handrails shall be 1-1/4" to 2" cross
section, spaced minimum of 1-1/2" from
vail. 2-3307(e.l)
n. A 2" high curb or wheel guide rail
centered 3" ± 1" above ramp surface is
required on both sides vhere not
otherwise bounded by walls when the ramp
exceeds 10 feet in length.
2-3307(h.l)
ECIAL ACCESS LIFTS
Lifts may be provided between levels, in
lieu of elevator, when the vertical
distance between landings, structural
elevator, structural design and
safeguards are as allowed by the State
of California, Department of Industrial
Relations, Division of Occupational
Safety and Health. 2-5107(a) .
The lift platform shall be of sufficient
size to accommodate a wheelchair
(30"x48"). 2-5107(a)
There shall be a level and clear floor
area or landing (60"x60") at each level
for access to the lift. 2-5107(a)
HAZARDS
a. Provide 80" headroom from walkway
surface to any overhanging obstruction.2-3326(b)
G)
c. Protruding objects with leading edges
between 27" and 80" above finished floor
shall not protrude more than V into
walks, corridors, etc. 2-522(f)
d. Free standing objects mounted on posts
between 27" and 80" above the floor nay
project a maximum of 12". 2-522(f)
e. Abrupt ' changes in level exceeding 4"
adjacent to walks, except between walks
and adjacent streets or drives, shall be
identified by 6" high warning curbs above
walk surface. 2-3326(a)
ENTRANCES AND dRCOLAHC*
1.) ENTRANCES, DOORS, VESTIBULES AND CORRIDORS
a. All primary entrances to buildings shall
be accessible to the handicapped.
2-3301(£)
b. All required passage doors shall have 32"
clear opening at 90 degrees (36" door).
2-3304(f)
c. At least one of a pair of doors shall
meet the minimum 32" clear entrance width
requirement. 2-3304(f)
d. Threshold shall be no higher than 1/2"
above the floor. Edge to be beveled with
a slope no greater than 1 in 2, if more
than 1/4". 3304(i.l)
e. Exterior level landing may slope up to
1/4" per • foot in any direction for
surface drainage. 2-413
f. Door hardware shall be of the lever or
push type, mounted 30" to 44" above the
floor and be operable with a maximum
effort of 8.5 Ibs. for exterior doors and
5 Ibs. for interior doors. 2-3304(c), 2-
3304(i.2)
g. The lower 10" of the door shall be of
smooth, plane surface (no recess or trap)
except at automatic and sliding doors.
2-3304(i.3)
h. Building entrance(s) shall be identified
by sign with the International Symbol of
Accessibility. Show location on plan.
The symbol shall be a white figure on
blue background. 2-522(b)
i. At turnstile, provide an access gate, 32"
clear width opening, within 30 feet of
turnstile. 2-3304(1.4)
j. There shall be a clear area on each side
of door, 60" deep in direction of door
swing and 44" deep in opposite direction
of door swing. 2-3304(i.l)
Width of clear area on the swing side of
the door shall extend 24" past strike
janb for exterior doors and 18" past
strike janb for interior doors.
2-3304(1.1)
003
The space between two consecutive doers
(vestibule) shall provide a minimum of
**8" clear depth between the open door
and a second closed door.Doors in a
series at a vestibule shall swing in the
same direction, or away from the spaca
between them. 2-3304(i.l)
For corridors over 200 feet long, see
special requirements of Sec. 2-3305(b)2,
FLOORS
Floors of a given story shall be a
c onzion. 1 eve 1 throughout or sha 11 be
connected by pedestrian ramps, passenger
elevators, or s pecial access lifts.
2-522(e)
STAIRWAYS
OTE: Only applies where disabled access is
provided or required to other levels.
Treads shall have smooth, rounded
exposed edges and be slip resistant. 2-
3306(s)
Nosing shall net project more than
1-1/2 inches past face of the riser
below. 2-3306(s)
Risers shall be sufficiently solid.
2-3306(s)
The upper approach and lover tread of
each flight of stairs shall be Barked
with a contrasting colored strip 2" in
width. 2-3306(r)
On exterior stairs, each, tread shall be
marked as noted above. 2-3306(r)
Handrails are required on eacfr side of
stairvay. 2-3306
Handrails shall be located 30" to 34"
above nosing,extend 12" beyond top riser
and 12" plus tread, width beyond bottom
nosing and returned to wall/newel post.
2-3306(j.l).
Handrails shall be 1*1/4" to 2" in
gripping cross section and 1-1/2" clear
of wall. 2-3306(j.l)
Approved stairvay identification signs
shall be located at each floor level in
all enclosed stairways in buildings two
or more stories in height. The sign
shall identify the stairvay, indicate
whether there is roof access, the floor
level, and the upper and lower terainus
of the stairvay. The information shall
be presented using raised Arabic numerals
and raised braille symbols which conform
to Section 522(b)3. The sign shall be
located approximately 5 feet above the
floor landing iroediately adjacent to the
doer on the strike side. Signs shall
comply with requirements of U.B.C.
Standard Ko. 33-2,
ELEVATORS
fa. Provide clear inside elevator car
dimensions as required by U.B.C. Section
5103(d) 6 and Title 24 2-5103(d.l).
1. At least one elevator in buildings 4
or more stories in height: SO" "by
54", with a 42-inch -side slide door.
Applies only to: high-rise buildings,
A/E/I occupancies, State-owned
buildings, residential care hooes,
hotels, motels, apartments and
condominiums.
2. Elevator in buildings more than two
stories or buildings where disabled
access is required to upper level(s):
68" by 54", with a minimum clear door
width of 36".
3. Elevators other than in (b) above
serving less than 50 occupants shall
have a minimum inside platform of 4
feet 6 inches by 4 feet 6 inches and a
minimum clear door width of 36 inches.
b. Raised Braille markings and Arabic
numerals are required on control buttons
and door jambs. 2-5103(d.l)
SANITARY 7ACTUT1KS
, TOILET FACILITIES ACCESS
located on accessible floors,
sanitary facilities shall be cade
accessible to physically handicapped.
(2-511.l(a))
i. Doorways ' shall have 32" minimum clear
opening width. 2-511.1
:. There shall be a level area with 60"
clear depth in the direction of the door
swing, and a level area with 44" clear
depth in opposite direction of door
sving. 2-511.1(a)
MULTIPLE ACCOMMODATION TOILET FACILITIES
*. Provide clear area
high - or clear space
high. 2-511.l(a)
60" diameter x 27"
56" x 63" x 27"
bT/Doors (other than handicap compartment)
axe not to encroach more than 12" into
above mentioned clear space.
2-511.l(a)
c.Jprovide a 28" clear space between water
^—--"closet and fixture or 32" clear space
between water closet and wall.
2-511.l(a)
A 48" long clear space is required in
front of water closet. A 60" clear
space is required when the toilet
cDepartment has a side door.
2-511.l(a)
f e,/Water closet compartment door to provide
*•— 22" clear width for end entry and 24"
clear width for side entry. Door to be
self-closing. 2-511.l(a)
SINGLE ACCOMMODATION TOILET FACILITIES
Water closet shall be located 28" from a
fixture or 22" froa a wall. 2-511.l(a)
\ . Minimum clear space in front of water
closet shall be 48". 2-511.l(a)
In an existing building, a single
accommodation toilet facility may have a
space 36" vide x 48 " long in front of
water closet. 2-511.l(a)
14 ../GRAB BARS AT WATER CLOSET
a. One at side 42" long extending 24" in
front of water closet; one at rear 26"
long centered on water closet; both
mounted 33" above floor. Where a tank-
type toilet is used, grab bar may be as
high as 36". 2-511.l(a)
b. Bars shall be 1-1/4" to 1-1/2" in
diameter with 1-1/2" clearance to wall.
2-511.l(a)
c. Bar fasteners-and mounting support shall
be able to withstand '250 Ibs./ft. in
bending, shear and tension.
WATER CLOSET
a. Height of water closet seat shall be 17"
to 19" above floor. 5-1502
b. Controls shall be operable with one
hand, and shall not require tight
grasping, pinching or twisting of the
wrist. 5-1502
c. Controls for the flush valves shall be
mounted on the wide side of toilet
areas, no more than 44" above the floor.
5-1502
d. The force required to activate controls
shall be no greater than 5 pounds force.
5-1502
16V URINALS . - -
a. Where urinals are provided, the rim of at
least one shall project 14" from the wall
and be located 17" maximim above floor.
5-1503(a)
b. The force required to activate the flush
valve shall be 5 Ibs. naxiaua and located
44" aaxiuuLi above floor.
5-1503(b)
c. Provide 30" x 48" clear floor space for
forward approach. 2-511.l(b)
YATORIES
a. Provide 30" x 48" clear floor space for
forward approach. Said clear floor space
cay include knee and toe space under
lavatory described below.
b. Provide clear space beneath lavatories
29" high by 20" wide by 8" deep at top
and 9" high by 30" wide by 17" deep at
bottom from front of lavatory (toe
space) . The maximum counter surface
height should be 34". 5-1504(a)
c. Hot water and drain pipes under
lavatories shall be insulated.
5-1504(b)
d. faucet controls and operating mechanism
(operable with one hand) shall be of the
type not requiring tight grasping,
pinching or twisting of the wrist (such
as lever-operated) and an operating force
not exceeding 5 Ibs. 5-1504(c)
e. If self-closing valves are used, they
shall remain open for at least 10
seconds. 5-1504(c)
JILEI ROOM ACCESSORIES
a. Mirror bottom, edge shall be located 40"
maximum above floor. 2-511. l(b)
b. Toilet tissue dispensers shall be mounted
within 12" from the front edge of toilet
seat. 2-511. l(b)
c. Operating parts of dispensing and
disposal fixtures (towels, waste, coin
slots, etc.) shall be within 40" of
floor. 2-511.1(b)
19 JSAKIIARY FACILITIES IDENTIFICAIIOH
a. On doorways leading to sanitary
facilities the symbols to be provided are
12" Equilateral triangle for men, 12"
diameter circle for women, and 1/4"
thick, centered on door, 60" high and
contrasting color. Unisex facilities
shall be identified by the circle with
the triangle superimposed within the
circle. 2-511. l(a>
BATHING FACILITIES
aL One such facility shall comply when
provided for the public, clients or
employees. 2-511.1(a)
Shower compartment shall be 42" vide,
i.S" deep, with a 36" wide entrance.
2-511.l(a)
Show on the plans that the handicapped
bathing facilities shall conform to
requirements of Sec. 2-511a-9, 5-1505
and 5-1506, i.e., folding seat, flexible
shover hose, etc.
GENERAL KEQQTSEMQTIS
2iJ DRINKING "FOUNTAIN
a. Drinking fountains shall be within
alcoves. The alcove shall be not less
than 32" vide by 18" deep. 2-511.l(c)
b. When the enforcing agency determines
that it would create an unreasonable
hardship to locate the water fountain in
an alcove, the water fountain cay
project into the path of travel, and the
path of travel shall be identifiable to
the blind as follows:
(1.) The surface of the path of travel
at the water fountain shall be textured
so that it is clearly identifiable by a
blind person using a cane. The minimum
textured area shall extend from the wall
supporting the water fountain to 1 foot
beyond the front edge of the water
fountain and shall extend 1 foot beyond
each side of the water fountain, or
(2.) Wing walls shall be provided on
each side of the water fountain. The
wing walls shall project out from the
supporting wall at least as far as the
water fountain to within 6 inches of the
surface of the path of travel. Also,
there shall be a. minimum of 32 inches
clear between the wing vails.
c. Note on the plans that drinking fountain
shall conform to requirements of
Sec. 2-511c and 5-1507.
22.) PUBLIC TELEPHONE
a. Provide space 30" x 48" for forward or
parallel approach to telephone.
2-511.l(d)
b. Note on the plans that public telephone
shall conform to requirements of
Sec. 2-511.l(d).
ELECTRICAL REQUIREMENTS
15, 20 and 30 amp receptacle outlets
shall be installed not less than 12"
above floor. 3-210-50(e)
Center of switches shall be located not
less than 36" nor more than 48" above
the floor. 3-380-8(c)
2k.)PLUMBING REQUIREMENTS
a. Where kitchenettes are provided at
employee break rooms, conference areas,
customer lounges, etc., the faucet
controls at kitchen sinks shall be
operable with one hand and shall not
require tight grasping, pinching or
twisting of the wrist (i.e., use lever-
operated, push-type, etc.). If self-
closing valves are used, they shall
remain open for at least 10 seconds.
5-1503
GRDDP A OCCOPANCT
AUDITORIUMS, ASSEMBLY HALLS, THEATRES, ETC.
Seating and toilet facilities for the
handicapped shall be accessible from the
main lobby or prirary entrance.
2-611(b)
This structure requires _wheelchair seating spaces. In theaters
and auditoriuns, the seating shall be
provided in a variety of locations so as
to provided a choice of admission prices.
2-611(b)
Each wheelchair space shall be 60" x 30"
and level. 2-611(b)
When the seating capacity exceeds 300,
the wheelchair spaces shall be in more
than one location. 2-611(b)
This structure requires
seats for semi-ambulant persons.Clear
leg space shall be at least
2-611(b)
24'
Stages, enclosed and unenclosed
platforms, orchestra pits, ticket booths,
and refreshment sales facilities shall be
made accessible. 2-611(b)
6. STADIUMS, GRANDSTANDS, BLEACHERS, PAVILIONS,
IUKS
This structure requires
wheelchair seating spaces
and auditoriums, the
provided in
In theaters
seating shall be
,_. .... a variety of locations so as
to provided a choice of admission prices.
2-611(c)
When the seating capacity exceeds 300,
the wheelchair spaces shall be in more
than one location. 2-611(c)
c. Ticket booths must be accessible from
both sides. 2-611(c)
d. Participation areas such as ball courts,
exercise rooms, tracks, and clubrooms
oust be accessible. 2-611(c)
e. Spectator and participant sanitary and
locker facilities must conform to the
requirements of Chapter 2-5.
2-611(c)
.
\ MBCfflOTCAL/HflMMk;""
PLAN CORKBCnOff SHEET
^. GLEH ADAKEK
EUH CflBOt KMBER: _ " 8 ? t* J- PLAN CHECKER: Q •
D
. C.AC-
Prepared byi
Jurisdiction CARLSBAD
VALUATION AND PLAN CHECK FEE
Bldg. Dept.
Esgil
PLAN CHECK K0._ ^3
BUILDING ADDRESS /9O/
APPLICANT/CONTACT
BUILDING OCCUPANCY
vi&A
PHONE NO.
DESIGNER PHONE
TYPE OF CONSTRUCTION CONTRACTOR PHONE
BUILDING PORTION
"TX: •
Air Conditionine
Commercial
Residential
Res. or Comm.
Fire Sprinklers
Total Value
BUILDING AREA
rz.0
•
VALUATION
MULTIPLIER
~ZS~
'e
@
e • •
VALUE
/jo vzs-
•
/ JO V7J"
Building Permit Tee S,
Plan Check Fee $
C 0 M ME NT Si.
SHEET OF /
12/87
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS ) <?Q /
DATE
D/Q/I 3=1=
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITION MINOR
« $10,000.00}
OTHER
PLAZA CAMINO REAL
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
PLANNER DATE
ENGINEER DATE
C:\WP51\FILES\BLDG.FRM Rev 11/15/90
City of Carlsbad 93125
Fire Department • Bureau of Prevention
Plan Review: Requirements Category: Building Plan Check
Date of Report: Tuesday. September 28,1993 Reviewed by
Contact Name
Address 515 S. Flower St Ste 1250
City, State Los Angeles CA 90071
Bldg. Dept. No. 93-876 Planning No.
Job Name Merrill Lynch
Job Address 1901 Camino Vida Robie Ste. or Bldg. No. 100
E3 Approved - The item you have submitted for review has been approved. The approval is
based on plans; information and/or specifications provided in your submittal;
therefore any changes to these items after this date, including field modifica-
tions, must be reviewed by this office to insure continued conformance with
applicable codes. Please review carefully all comments attached, as failure
to comply with instructions in this report can result in suspension of permit to
construct or install improvements.
D Disapproved - Please see the attached report of deficiencies. Please make corrections to
plans or specifications necessary to indicate compliance with applicable
codes and standards. Submit corrected plans and/or specifications to this
office for review.
For Fire Department Use Only
Review 1st 2nd 3rd
Other Agency ID
CFD Job# 93125 File# _^_^___
2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121
City of Carlsbad 93125
Fire Department • Bureau of Prevention
Plan Review: Requirements Category: Building Plan Check
Date of Report: Friday. SeptembeMO. 1993 Reviewed by:_
Contact Name Kim Sung
Address 515 S. Flower St Ste 1250
City, State Los Angeles CA 90071
Bldg. Dept. No. 93-876 Planning No.
Job Name Merrill Lynch
Job Address 1901 Camino Vida Roble Ste. or Bldg. No. 10Q_
Approved - The item you have submitted for review has been approved. The approval is
based on plans; information and/or specifications provided in your submittal;
therefore any changes to these items after this date, including field modifica-
tions, must be reviewed by this office to insure continued conformance with
applicable codes. Please review carefully all comments attached, as failure
to comply with instructions in this report can result in suspension of permit to
construct or install improvements.
Disapproved - Please see the attached report of deficiencies. Please make corrections to
plans or specifications necessary to indicate compliance with applicable
codes and standards. Submit corrected plans and/or specifications to this
office for review.
For Fire Department Use Only
Review 1 st 2nd 3rd
Other Agency ID
CFD Job# 93125 File#
2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121